Page MenuHomeFreeBSD

uart/pci: recover ADL AMT device after FIFO size probing
Needs ReviewPublic

Authored by royger on Fri, Mar 27, 10:01 AM.
Tags
None
Referenced Files
Unknown Object (File)
Wed, Apr 1, 11:41 PM
Unknown Object (File)
Wed, Apr 1, 8:46 AM
Unknown Object (File)
Mon, Mar 30, 7:40 PM
Unknown Object (File)
Sun, Mar 29, 5:02 AM
Unknown Object (File)
Fri, Mar 27, 11:06 AM
Subscribers
None

Details

Reviewers
marcel
imp
Summary

When the Alder Lake Serial-over-LAN device is put into loopback mode and
repeated writes are performed to the data register it results in the device
ending up in a non-functional state afterwards.

Recovering the device to a working state requires re-writing the LCR
register with it's current value (no effective change). This should be
harmless on all other devices.