If a property set of CC requests both a shutdown (by setting CC.SHN to
a nonzero value) and controller enable (by setting CC.EN=1), give
precedence to the shutdown request and force CC.EN to 0.
Sponsored by: Chelsio Communications
Differential D60471 Authored by jhb on Oct 8 2026, 3:51 PM.
Project Tags None Referenced Files
Subscribers
Details
Summary If a property set of CC requests both a shutdown (by setting CC.SHN to Sponsored by: Chelsio Communications
Diff Detail
Event TimelineHerald added a subscriber: imp. · View Herald TranscriptOct 8 2026, 3:51 PM2026-10-08 15:51:23 (UTC+0) Harbormaster completed remote builds in B77855: Diff 189062.Oct 8 2026, 3:51 PM2026-10-08 15:51:27 (UTC+0) This revision is now accepted and ready to land.Oct 14 2026, 3:44 PM2026-10-14 15:44:44 (UTC+0) Comment Actions
No, for PCIe controllers this would be in the firmware/ASIC. Note that this stack of change are all on the controller side, so think of it as equivalent to the firmware/ASIC, not nvme(4).
Revision Contents