Page MenuHomeFreeBSD

powerpc: change mfpvr return type to uint32_t
ClosedPublic

Authored by luporl on Jul 28 2021, 12:41 PM.
Tags
None
Referenced Files
Unknown Object (File)
Fri, Oct 3, 3:55 AM
Unknown Object (File)
Sun, Sep 28, 1:15 AM
Unknown Object (File)
Thu, Sep 25, 6:27 AM
Unknown Object (File)
Thu, Sep 11, 10:17 AM
Unknown Object (File)
Thu, Sep 11, 4:01 AM
Unknown Object (File)
Tue, Sep 9, 4:04 AM
Unknown Object (File)
Sat, Sep 6, 8:35 PM
Unknown Object (File)
Fri, Sep 5, 6:26 AM
Subscribers

Details

Summary

As the Processor Version Register (PVR) is a 32-bit PowerPC
register, change mfpvr() return type to match it and avoid
type casts on its callers.

Suggested by: jhibbits

Test Plan

Tested on POWER9 VM and build tested on powerpc (32-bit).

Diff Detail

Repository
rG FreeBSD src repository
Lint
Lint Not Applicable
Unit
Tests Not Applicable

Event Timeline

This revision is now accepted and ready to land.Jul 28 2021, 2:21 PM

minor quibble, but likely not worth addressing.

sys/dev/hwpmc/hwpmc_powerpc.c
607

mfpvr() doesn't return an int now, but a uint32_t which can be either an int or a long. so there's still a mismatch here, just not one the compiler warns about. In the past, this would be a sure way to get a mismatch between 32-bit and 64-bit compiles, but it seems we've moved to always defining uint32_t as an unsigned int. At least the 'x' format is unsigned...

This revision was automatically updated to reflect the committed changes.