PC64: Get the timestap from the proper OF field
ClosedPublic

Authored by breno.leitao_gmail.com on Feb 5 2018, 5:23 PM.
Referenced Files
Unknown Object (File)
Feb 10 2024, 7:45 AM
Unknown Object (File)
Dec 20 2023, 4:43 AM
Unknown Object (File)
Dec 19 2023, 1:37 AM
Unknown Object (File)
Dec 12 2023, 5:53 AM
Unknown Object (File)
Nov 15 2023, 5:06 AM
Unknown Object (File)
Sep 6 2023, 5:19 AM
Unknown Object (File)
Sep 4 2023, 5:26 PM
Unknown Object (File)
Sep 4 2023, 5:25 PM
Subscribers

Details

Summary

After revision rS328534('PPC64: use hwref instead of cpuid'), FreeBSD on
powerpc64 virtual machine panics since it is unable to read the
timebase, showing the following error:

    
get-property for timebase-frequency on zero phandle
    
panic: Unable to determine timebase frequency!

With the change above, cpuref->cr_hwref does not contain the phandle
anymore, thus, it never reads the proper CPU entry in OF.

Diff Detail

Lint
Lint Skipped
Unit
Tests Skipped

Event Timeline

So I have a memory of OF properties not being NUL terminated. If so, this code is wrong, though it might accidentally be right in some cases.

sys/powerpc/pseries/platform_chrp.c
300

Is buf NUL terminated?

307

Is buf NUL terminated?

Turns out IEEE 1275 standard and successors all guarantee that text strings are 1 to 31 characters followed by a NUL byte, so my worry is bogus.

Let me attach a new fix as proposed by Justin

jhibbits requested changes to this revision.Feb 8 2018, 5:31 PM

Fix those two nits, otherwise looks good.

sys/powerpc/pseries/platform_chrp.c
294

cpus is not a boolean, you should use cpus == 0.

302

Same as above here.

This revision now requires changes to proceed.Feb 8 2018, 5:31 PM
This revision is now accepted and ready to land.Feb 8 2018, 7:11 PM
This revision was automatically updated to reflect the committed changes.