Summary

Relying on the boot loader console configuration allows us to use a
common set of device hints for all SENTRY5 devices.

Depends on D7375

Test Plan
  • Check for correct initialization of uart1 console on WGT634U.
  • Check for regressions in uart0 console initialization on N16/N53.

Diff Detail

Repository
rS FreeBSD src repository - subversion
Lint
Lint Not Applicable
Unit
Tests Not Applicable

Event Timeline

landonf retitled this revision from to [mips/broadcom] Fetch UART console configuration from CFE..
landonf updated this object.
landonf edited the test plan for this revision. (Show Details)
landonf added a reviewer: adrian.
adrian edited edge metadata.
This revision is now accepted and ready to land.Jul 31 2016, 4:35 PM
This revision was automatically updated to reflect the committed changes.