Page MenuHomeFreeBSD

[mips/broadcom] Fetch UART console configuration from CFE.
ClosedPublic

Authored by landonf on Jul 30 2016, 11:43 PM.
Tags
None
Referenced Files
Unknown Object (File)
Thu, Nov 13, 2:40 PM
Unknown Object (File)
Thu, Nov 13, 12:53 AM
Unknown Object (File)
Wed, Nov 12, 10:16 PM
Unknown Object (File)
Wed, Nov 12, 6:12 PM
Unknown Object (File)
Wed, Nov 12, 4:48 PM
Unknown Object (File)
Sat, Nov 8, 9:06 PM
Unknown Object (File)
Tue, Oct 28, 2:35 AM
Unknown Object (File)
Mon, Oct 27, 1:06 AM
Subscribers

Details

Summary

Relying on the boot loader console configuration allows us to use a
common set of device hints for all SENTRY5 devices.

Depends on D7375

Test Plan
  • Check for correct initialization of uart1 console on WGT634U.
  • Check for regressions in uart0 console initialization on N16/N53.

Diff Detail

Repository
rS FreeBSD src repository - subversion
Lint
Lint Passed
Unit
No Test Coverage
Build Status
Buildable 4669
Build 4723: arc lint + arc unit

Event Timeline

landonf retitled this revision from to [mips/broadcom] Fetch UART console configuration from CFE..
landonf updated this object.
landonf edited the test plan for this revision. (Show Details)
landonf added a reviewer: adrian.
adrian edited edge metadata.
This revision is now accepted and ready to land.Jul 31 2016, 4:35 PM
This revision was automatically updated to reflect the committed changes.