Page MenuHomeFreeBSD

Get initial VCCQ voltage from FDT if available
Needs ReviewPublic

Authored by kibab on Nov 4 2020, 12:27 PM.
Tags
None
Referenced Files
F154243898: D27087.id.diff
Mon, Apr 27, 9:07 AM
Unknown Object (File)
Thu, Apr 23, 9:39 AM
Unknown Object (File)
Wed, Apr 22, 2:46 AM
Unknown Object (File)
Tue, Apr 21, 5:20 AM
Unknown Object (File)
Fri, Apr 17, 12:14 AM
Unknown Object (File)
Sun, Apr 5, 5:41 AM
Unknown Object (File)
Sun, Apr 5, 2:28 AM
Unknown Object (File)
Sat, Apr 4, 8:06 PM
Subscribers
None

Details

Reviewers
manu
imp

Diff Detail

Lint
Lint Passed
Unit
No Test Coverage
Build Status
Buildable 34621
Build 31710: arc lint + arc unit

Event Timeline

kibab requested review of this revision.Nov 4 2020, 12:27 PM
kibab created this revision.

One minor comment but looks ok otherwise.

sys/dev/mmc/mmc_fdt_helpers.c
174

Maybe add a default: with a printf under bootverbose if we can't get the current voltage ?