MFC r345475-r345476
r345475:
Truncate a too-long interrupt handler name when there is only one handler.
There are only 19 bytes available for the name of an interrupt plus the
name(s) of handlers/drivers using it. There is a mechanism from the days of
shared interrupts that replaces some of the handler names with '+' when they
don't all fit into 19 bytes.
In modern times there is typically only one device on an interrupt, but long
device names are the norm, especially with embedded systems. Also, in systems
with multiple interrupt controllers, the names of the interrupts themselves
can be long. For example, 'gic0,s54: imx6_anatop0' doesn't fit, and
replacing the device driver name with a '+' provides no useful info at all.
When there is only one handler but its name was too long to fit, this
change truncates enough leading chars of the handler name (replacing them
with a '-' char to indicate that some chars are missing) to use all 19
bytes, preserving the unit number typically on the end of the name. Using
the prior example, this results in: 'gic0,s54:-6_anatop0' which provides
plenty of info to figure out which device is involved.
PR: 211946
Reviewed by: gonzo@ (prior version without the '-' char)
Differential Revision: https://reviews.freebsd.org/D19675
r345476:
Revert accidental change that should not have been included in r345475.
I had changed this value as part of a local experiment, and neglected to
change it back before committing the other changes.