On Aero/Sea A0 cards retry MPT Fusion registers reads for max three times
Due to HW Errta on Aero/Sea A0 chipset on secure boot mode & on heavy IO load,
sometimes read operation on MPT Fusion registers will give zero value,
So, as a workaround driver will retry the MPT Fusion register
read operation for max three times upon reading zero value form these
registers.
Submitted by: Sreekanth Reddy <sreekanth.reddy@broadcom.com>
Reviewed by: Kashyap Desai <Kashyap.Desai@broadcom.com>
Approved by: ken
MFC after: 3 days
Sponsored by: Broadcom Inc