HomeFreeBSD

Add an IPMI attachment for PowerNV systems

Description

Add an IPMI attachment for PowerNV systems

IPMI access on PowerNV systems is done through the OPAL firmware. This adds a
simple attachment for communicating with the FSP/BMC on these machines. This
has been tested on a Talos POWER9 workstation, only in the bootup phase, noting
the successful attachment messages:

...
ipmi0: IPMI device rev. 0, firmware rev. 2.00, version 2.0, device support mask 0
ipmi0: Number of channels 2
...

The ipmi device has not been added to GENERIC64, but may be after further
testing. It may also eventually be added to the ipmi module at that point.

Details

Provenance
jhibbitsAuthored on
Parents
rS334014: Add a comment explaining the need of a global temporary variable
Branches
Unknown
Tags