MFC r278071:
Section 3.2.9 in the XHCI specification about control transfers says
that we should use a normal-TRB if there are more TRBs extending the
data-stage TRB. Add a dedicated state bit to the internal USB transfer
flags to handle this case.
Description
Description
Details
Details
- Provenance
• hselasky Authored on - Parents
- rS278508: MFC r278071:
- Branches
- Unknown
- Tags