Index: head/share/man/man4/muge.4 =================================================================== --- head/share/man/man4/muge.4 (revision 341648) +++ head/share/man/man4/muge.4 (revision 341649) @@ -1,72 +1,68 @@ .\" Copyright (c) 2018 The FreeBSD Foundation. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE .\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF .\" SUCH DAMAGE. .\" .\" $FreeBSD$ .\" .Dd June 11, 2018 .Dt MUGE 4 .Os .Sh NAME .Nm muge .Nd "Microchip LAN78xx USB Gigabit Ethernet driver" .Sh SYNOPSIS To load the driver as a module at boot time, place the following line in .Xr loader.conf 5 : .Bd -literal -offset indent if_muge_load="YES" .Ed -.Pp -.\" Alternatively, to compile this driver into the kernel, place the -.\" following lines in your kernel configuration file: -.Ed .Sh DESCRIPTION The .Nm device driver provides support for USB Gigabit Ethernet adapters based on Microchip's LAN78xx and LAN7515 chipsets. .Pp For more information on configuring this device, see .Xr ifconfig 8 . .Sh HARDWARE The .Nm driver supports: .Pp .Bl -bullet -compact .It Microchip LAN7800 USB 3.1 Gigabit Ethernet controller with PHY .It Microchip LAN7850 USB 2.0 Gigabit Ethernet controller with PHY .It Microchip LAN7515 USB 2 hub and Gigabit Ethernet controller with PHY .El .Sh SEE ALSO .Xr arp 4 , .Xr miibus 4 , .Xr usb 4 , .Xr ifconfig 8 .Sh HISTORY The .Nm device driver first appeared in .Fx 12.0 . Index: head/share/man/man4/vxlan.4 =================================================================== --- head/share/man/man4/vxlan.4 (revision 341648) +++ head/share/man/man4/vxlan.4 (revision 341649) @@ -1,246 +1,246 @@ .\" Copyright (c) 2014 Bryan Venteicher .\" All rights reserved. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE .\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF .\" SUCH DAMAGE. .\" .\" $FreeBSD$ .\" .Dd December 31, 2017 .Dt VXLAN 4 .Os .Sh NAME .Nm vxlan .Nd "Virtual eXtensible LAN interface" .Sh SYNOPSIS To compile this driver into the kernel, place the following line in your kernel configuration file: .Bd -ragged -offset indent .Cd "device vxlan" .Ed .Pp Alternatively, to load the driver as a module at boot time, place the following line in .Xr loader.conf 5 : .Bd -literal -offset indent if_vxlan_load="YES" .Ed .Sh DESCRIPTION The .Nm driver creates a virtual tunnel endpoint in a .Nm segment. A .Nm segment is a virtual Layer 2 (Ethernet) network that is overlaid in a Layer 3 (IP/UDP) network. .Nm is analogous to .Xr vlan 4 but is designed to be better suited for large, multiple tenant data center environments. .Pp Each .Nm interface is created at runtime using interface cloning. This is most easily done with the .Xr ifconfig 8 .Cm create command or using the .Va cloned_interfaces variable in .Xr rc.conf 5 . The interface may be removed with the .Xr ifconfig 8 .Cm destroy command. .Pp The .Nm driver creates a pseudo Ethernet network interface that supports the usual network .Xr ioctl 2 Ns s and is thus can be used with .Xr ifconfig 8 like any other Ethernet interface. The .Nm interface encapsulates the Ethernet frame by prepending IP/UDP and .Nm headers. Thus, the encapsulated (inner) frame is able to transmitted over a routed, Layer 3 network to the remote host. .Pp The .Nm interface may be configured in either unicast or multicast mode. When in unicast mode, the interface creates a tunnel to a single remote host, and all traffic is transmitted to that host. When in multicast mode, the interface joins an IP multicast group, and receives packets sent to the group address, and transmits packets to either the multicast group address, or directly the remote host if there is an appropriate forwarding table entry. .Pp When the .Nm interface is brought up, a -.Xr UDP 4 +.Xr udp 4 .Xr socket 9 is created based on the configuration, such as the local address for unicast mode or the group address for multicast mode, and the listening (local) port number. Since multiple .Nm interfaces may be created that either use the same local address or join the same group address, and use the same port, the driver may share a socket among multiple interfaces. However, each interface within a socket must belong to a unique .Nm segment. The analogous .Xr vlan 4 configuration would be a physical interface configured as the parent device for multiple VLAN interfaces, each with a unique VLAN tag. Each .Nm segment is identified by a 24-bit value in the .Nm header called the .Dq VXLAN Network Identifier , or VNI. .Pp When configured with the .Xr ifconfig 8 .Cm vxlanlearn parameter, the interface dynamically creates forwarding table entries from received packets. An entry in the forwarding table maps the inner source MAC address to the outer remote IP address. During transmit, the interface attempts to lookup an entry for the encapsulated destination MAC address. If an entry is found, the IP address in the entry is used to directly transmit the encapsulated frame to the destination. Otherwise, when configured in multicast mode, the interface must flood the frame to all hosts in the group. The maximum number of entries in the table is configurable with the .Xr ifconfig 8 .Cm vxlanmaxaddr command. Stale entries in the table periodically pruned. The timeout is configurable with the .Xr ifconfig 8 .Cm vxlantimeout command. The table may be viewed with the .Xr sysctl 8 .Cm net.link.vxlan.N.ftable.dump command. .Sh MTU Since the .Nm interface encapsulates the Ethernet frame with an IP, UDP, and .Nm header, the resulting frame may be larger than the MTU of the physical network. The .Nm specification recommends the physical network MTU be configured to use jumbo frames to accommodate the encapsulated frame size. Alternatively, the .Xr ifconfig 8 .Cm mtu command may be used to reduce the MTU size on the .Nm interface to allow the encapsulated frame to fit in the current MTU of the physical network. .Sh EXAMPLES Create a .Nm interface in unicast mode with the .Cm vxlanlocal tunnel address of 192.168.100.1, and the .Cm vxlanremote tunnel address of 192.168.100.2. .Bd -literal -offset indent ifconfig vxlan create vxlanid 108 vxlanlocal 192.168.100.1 vxlanremote 192.168.100.2 .Ed .Pp Create a .Nm interface in multicast mode, with the .Cm local address of 192.168.10.95, and the .Cm group address of 224.0.2.6. The em0 interface will be used to transmit multicast packets. .Bd -literal -offset indent ifconfig vxlan create vxlanid 42 vxlanlocal 192.168.10.95 vxlangroup 224.0.2.6 vxlandev em0 .Ed .Pp Once created, the .Nm interface can be configured with .Xr ifconfig 8 . -.Ed .Pp The following when placed in the file .Pa /etc/rc.conf will cause a vxlan interface called .Dq Li vxlan0 to be created, and will configure the interface in unicast mode. .Bd -literal -offset indent cloned_interfaces="vxlan0" create_args_vxlan0="vxlanid 108 vxlanlocal 192.168.100.1 vxlanremote 192.168.100.2" +.Ed .Sh SEE ALSO .Xr inet 4 , .Xr inet6 4 , .Xr vlan 4 , .Xr rc.conf 5 , .Xr ifconfig 8 , .Xr sysctl 8 .Rs .%A "M. Mahalingam" .%A "et al" .%T "Virtual eXtensible Local Area Network (VXLAN): A Framework for Overlaying Virtualized Layer 2 Networks over Layer 3 Networks" .%D August 2014 .%O "RFC 7348" .Re -.Sh AUTHOR +.Sh AUTHORS .An -nosplit The .Nm driver was written by .An Bryan Venteicher Aq bryanv@freebsd.org .