head/share/man/man4/imcsmb.4
Property | Old Value | New Value |
---|---|---|
svn:eol-style | null | native \ No newline at end of property |
svn:keywords | null | FreeBSD=%H \ No newline at end of property |
svn:mime-type | null | text/plain \ No newline at end of property |
.\" | |||||
.\" SPDX-License-Identifier: BSD-2-Clause-FreeBSD | |||||
.\" | |||||
.\" Copyright (c) 2018 Panasas | |||||
.\" All rights reserved. | |||||
.\" | |||||
.\" Redistribution and use in source and binary forms, with or without | |||||
.\" modification, are permitted provided that the following conditions | |||||
.\" are met: | |||||
.\" 1. Redistributions of source code must retain the above copyright | |||||
.\" notice, this list of conditions and the following disclaimer. | |||||
.\" 2. Redistributions in binary form must reproduce the above copyright | |||||
.\" notice, this list of conditions and the following disclaimer in the | |||||
.\" documentation and/or other materials provided with the distribution. | |||||
.\" | |||||
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR | |||||
.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES | |||||
.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. | |||||
.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, | |||||
.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT | |||||
.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, | |||||
.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY | |||||
.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT | |||||
.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF | |||||
.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. | |||||
.\" | |||||
.\" $FreeBSD$ | |||||
.\" | |||||
.Dd March 2, 2018 | |||||
.Dt IMCSMB 4 | |||||
.Os | |||||
.Sh NAME | |||||
.Nm imcsmb | |||||
.Nd Intel integrated Memory Controller (iMC) SMBus controller driver | |||||
.Sh SYNOPSIS | |||||
.Cd device pci | |||||
.Cd device smbus | |||||
.Cd device imcsmb | |||||
.Pp | |||||
Alternatively, to load the driver as a module at boot time, place the following | |||||
line in | |||||
.Xr loader.conf 5 : | |||||
.Bd -literal -offset indent | |||||
imcsmb_load="YES" | |||||
.Ed | |||||
.Sh DESCRIPTION | |||||
The | |||||
.Nm | |||||
driver provides | |||||
.Xr smbus 4 | |||||
support for the SMBus controller functionality in the integrated Memory | |||||
Controllers (iMCs) embedded in Intel Sandybridge-Xeon, Ivybridge-Xeon, | |||||
Haswell-Xeon, and Broadwell-Xeon CPUs. | |||||
Each CPU implements one or more iMCs, depending on the number of cores; | |||||
each iMC implements two SMBus controllers (iMC-SMBs). | |||||
The iMC-SMBs are used by the iMCs to read configuration information from the | |||||
DIMMs during POST. | |||||
They may also be used, by motherboard firmware or a BMC, to monitor the | |||||
temperature of the DIMMs. | |||||
.Pp | |||||
The iMC-SMBs are | |||||
.Sy not | |||||
general-purpose SMBus controllers. | |||||
By their nature, they are only ever attached to DIMMs, so they implement only | |||||
the SMBus operations need for communicating with DIMMs. | |||||
Specifically: | |||||
.Pp | |||||
.Bl -dash -offset indent -compact | |||||
.It | |||||
READB | |||||
.It | |||||
READW | |||||
.It | |||||
WRITEB | |||||
.It | |||||
WRITEW | |||||
.El | |||||
.Pp | |||||
A more detailed discussion of the hardware and driver architecture can be found | |||||
at the top of | |||||
.Pa sys/dev/imcsmb/imcsmb_pci.c . | |||||
.Sh WARNINGS | |||||
As mentioned above, firmware might use the iMC-SMBs to read DIMM temperatures. | |||||
The public iMC documentation does not describe any sort of coordination | |||||
mechanism to prevent requests from different sources -- such as the motherboard | |||||
firmware, a BMC, or the operating system -- from interfering with each other. | |||||
.Pp | |||||
.Bf Sy | |||||
Therefore, it is highly recommended that developers contact the motherboard | |||||
vendor for any board-specific instructions on how to disable and re-enable DIMM | |||||
temperature monitoring. | |||||
.Ef | |||||
.Pp | |||||
DIMM temperature monitoring should be disabled before returning from | |||||
.Fn imcsmb_pci_request_bus , | |||||
and re-enabled before returning from | |||||
.Fn imcsmb_pci_release_bus . | |||||
The driver includes comments to that effect at the appropriate locations. | |||||
The driver has been tested and shown to work, with only that type of | |||||
modification, on certain motherboards from Intel. | |||||
.Po | |||||
Unfortunately, those modifications were based on material covered under a | |||||
non-disclosure agreement, and therefore are not included in this driver. | |||||
.Pc | |||||
The driver has also been tested and shown to work as-is on various motherboards | |||||
from SuperMicro. | |||||
.Pp | |||||
The | |||||
.Xr smb 4 | |||||
driver will connect to the | |||||
.Xr smbus 4 | |||||
instances created by | |||||
.Nm . | |||||
However, since the IMC-SMBs are not general-purpose SMBus controllers, using | |||||
.Xr smbmsg 8 | |||||
with those | |||||
.Xr smb 4 | |||||
devices is not supported. | |||||
.Sh SEE ALSO | |||||
.Xr jedec_dimm 4 , | |||||
.Xr smbus 4 | |||||
.Sh HISTORY | |||||
The | |||||
.Nm | |||||
driver first appeared in | |||||
.Fx 12.0 . | |||||
.Sh AUTHORS | |||||
The | |||||
.Nm | |||||
driver was originally written for Panasas by | |||||
.An Joe Kloss . | |||||
It was substantially refactored, and this manual page was written, by | |||||
.An Ravi Pokala Aq Mt rpokala@freebsd.org |