diff --git a/zh_CN.GB2312/books/handbook/Makefile b/zh_CN.GB2312/books/handbook/Makefile index 6a5f859200..075b19b06f 100644 --- a/zh_CN.GB2312/books/handbook/Makefile +++ b/zh_CN.GB2312/books/handbook/Makefile @@ -1,312 +1,311 @@ # # $FreeBSD$ # # Build the FreeBSD Handbook (Simplified Chinese). # -# Original revision: 1.111 +# Original revision: 1.112 # ------------------------------------------------------------------------ # # Handbook-specific variables # # WITH_PGPKEYS The print version of the handbook only prints PGP # fingerprints by default. If you would like for the # entire key to be displayed, then set this variable. # This option has no affect on the HTML formats. # # Handbook-specific targets # # pgpkeyring This target will read the contents of # pgpkeys/chapter.sgml and will extract all of # the pgpkeys to standard out. This output can then # be redirected into a file and distributed as a # public keyring of FreeBSD developers that can # easily be imported into PGP/GPG. # # ------------------------------------------------------------------------ # # To add a new chapter to the Handbook: # # - Update this Makefile, chapters.ent and book.sgml # - Add a descriptive entry for the new chapter in preface/preface.sgml # # ------------------------------------------------------------------------ .PATH: ${.CURDIR}/../../share/sgml/glossary MAINTAINER= doc@FreeBSD.org DOC?= book FORMATS?= html-split HAS_INDEX= true USE_PS2PDF= yes INSTALL_COMPRESSED?= gz INSTALL_ONLY_COMPRESSED?= IMAGES_EN = advanced-networking/isdn-bus.eps IMAGES_EN+= advanced-networking/isdn-twisted-pair.eps IMAGES_EN+= advanced-networking/natd.eps IMAGES_EN+= advanced-networking/net-routing.pic IMAGES_EN+= advanced-networking/static-routes.pic IMAGES_EN+= geom/striping.pic IMAGES_EN+= install/adduser1.scr IMAGES_EN+= install/adduser2.scr IMAGES_EN+= install/adduser3.scr IMAGES_EN+= install/boot-loader-menu.scr IMAGES_EN+= install/boot-mgr.scr IMAGES_EN+= install/config-country.scr IMAGES_EN+= install/console-saver1.scr IMAGES_EN+= install/console-saver2.scr IMAGES_EN+= install/console-saver3.scr IMAGES_EN+= install/console-saver4.scr IMAGES_EN+= install/disklabel-auto.scr IMAGES_EN+= install/disklabel-ed1.scr IMAGES_EN+= install/disklabel-ed2.scr IMAGES_EN+= install/disklabel-fs.scr IMAGES_EN+= install/disklabel-root1.scr IMAGES_EN+= install/disklabel-root2.scr IMAGES_EN+= install/disklabel-root3.scr IMAGES_EN+= install/disk-layout.eps IMAGES_EN+= install/dist-set.scr IMAGES_EN+= install/dist-set2.scr IMAGES_EN+= install/docmenu1.scr IMAGES_EN+= install/ed0-conf.scr IMAGES_EN+= install/ed0-conf2.scr IMAGES_EN+= install/edit-inetd-conf.scr IMAGES_EN+= install/fdisk-drive1.scr IMAGES_EN+= install/fdisk-drive2.scr IMAGES_EN+= install/fdisk-edit1.scr IMAGES_EN+= install/fdisk-edit2.scr IMAGES_EN+= install/ftp-anon1.scr IMAGES_EN+= install/ftp-anon2.scr IMAGES_EN+= install/hdwrconf.scr IMAGES_EN+= install/keymap.scr IMAGES_EN+= install/main1.scr IMAGES_EN+= install/mainexit.scr IMAGES_EN+= install/main-std.scr IMAGES_EN+= install/main-options.scr IMAGES_EN+= install/main-doc.scr IMAGES_EN+= install/main-keymap.scr IMAGES_EN+= install/media.scr IMAGES_EN+= install/mouse1.scr IMAGES_EN+= install/mouse2.scr IMAGES_EN+= install/mouse3.scr IMAGES_EN+= install/mouse4.scr IMAGES_EN+= install/mouse5.scr IMAGES_EN+= install/mouse6.scr IMAGES_EN+= install/mta-main.scr IMAGES_EN+= install/net-config-menu1.scr IMAGES_EN+= install/net-config-menu2.scr IMAGES_EN+= install/nfs-server-edit.scr IMAGES_EN+= install/ntp-config.scr IMAGES_EN+= install/options.scr IMAGES_EN+= install/pkg-cat.scr IMAGES_EN+= install/pkg-confirm.scr IMAGES_EN+= install/pkg-install.scr IMAGES_EN+= install/pkg-sel.scr IMAGES_EN+= install/probstart.scr IMAGES_EN+= install/routed.scr IMAGES_EN+= install/security.scr IMAGES_EN+= install/sysinstall-exit.scr IMAGES_EN+= install/timezone1.scr IMAGES_EN+= install/timezone2.scr IMAGES_EN+= install/timezone3.scr IMAGES_EN+= install/userconfig.scr IMAGES_EN+= install/userconfig2.scr IMAGES_EN+= mail/mutt1.scr IMAGES_EN+= mail/mutt2.scr IMAGES_EN+= mail/mutt3.scr IMAGES_EN+= mail/pine1.scr IMAGES_EN+= mail/pine2.scr IMAGES_EN+= mail/pine3.scr IMAGES_EN+= mail/pine4.scr IMAGES_EN+= mail/pine5.scr IMAGES_EN+= install/example-dir1.eps IMAGES_EN+= install/example-dir2.eps IMAGES_EN+= install/example-dir3.eps IMAGES_EN+= install/example-dir4.eps IMAGES_EN+= install/example-dir5.eps IMAGES_EN+= security/ipsec-network.pic IMAGES_EN+= security/ipsec-crypt-pkt.pic IMAGES_EN+= security/ipsec-encap-pkt.pic IMAGES_EN+= security/ipsec-out-pkt.pic IMAGES_EN+= vinum/vinum-concat.pic IMAGES_EN+= vinum/vinum-mirrored-vol.pic IMAGES_EN+= vinum/vinum-raid10-vol.pic IMAGES_EN+= vinum/vinum-raid5-org.pic IMAGES_EN+= vinum/vinum-simple-vol.pic IMAGES_EN+= vinum/vinum-striped-vol.pic IMAGES_EN+= vinum/vinum-striped.pic IMAGES_EN+= virtualization/parallels-freebsd1.png IMAGES_EN+= virtualization/parallels-freebsd2.png IMAGES_EN+= virtualization/parallels-freebsd3.png IMAGES_EN+= virtualization/parallels-freebsd4.png IMAGES_EN+= virtualization/parallels-freebsd5.png IMAGES_EN+= virtualization/parallels-freebsd6.png IMAGES_EN+= virtualization/parallels-freebsd7.png IMAGES_EN+= virtualization/parallels-freebsd8.png IMAGES_EN+= virtualization/parallels-freebsd9.png IMAGES_EN+= virtualization/parallels-freebsd10.png IMAGES_EN+= virtualization/parallels-freebsd11.png IMAGES_EN+= virtualization/parallels-freebsd12.png IMAGES_EN+= virtualization/parallels-freebsd13.png IMAGES_EN+= virtualization/virtualpc-freebsd1.png IMAGES_EN+= virtualization/virtualpc-freebsd2.png IMAGES_EN+= virtualization/virtualpc-freebsd3.png IMAGES_EN+= virtualization/virtualpc-freebsd4.png IMAGES_EN+= virtualization/virtualpc-freebsd5.png IMAGES_EN+= virtualization/virtualpc-freebsd6.png IMAGES_EN+= virtualization/virtualpc-freebsd7.png IMAGES_EN+= virtualization/virtualpc-freebsd8.png IMAGES_EN+= virtualization/virtualpc-freebsd9.png IMAGES_EN+= virtualization/virtualpc-freebsd10.png IMAGES_EN+= virtualization/virtualpc-freebsd11.png IMAGES_EN+= virtualization/virtualpc-freebsd12.png IMAGES_EN+= virtualization/virtualpc-freebsd13.png IMAGES_EN+= virtualization/vmware-freebsd01.png IMAGES_EN+= virtualization/vmware-freebsd02.png IMAGES_EN+= virtualization/vmware-freebsd03.png IMAGES_EN+= virtualization/vmware-freebsd04.png IMAGES_EN+= virtualization/vmware-freebsd05.png IMAGES_EN+= virtualization/vmware-freebsd06.png IMAGES_EN+= virtualization/vmware-freebsd07.png IMAGES_EN+= virtualization/vmware-freebsd08.png IMAGES_EN+= virtualization/vmware-freebsd09.png IMAGES_EN+= virtualization/vmware-freebsd10.png IMAGES_EN+= virtualization/vmware-freebsd11.png IMAGES_EN+= virtualization/vmware-freebsd12.png # Images from the cross-document image library IMAGES_LIB= callouts/1.png IMAGES_LIB+= callouts/2.png IMAGES_LIB+= callouts/3.png IMAGES_LIB+= callouts/4.png IMAGES_LIB+= callouts/5.png IMAGES_LIB+= callouts/6.png IMAGES_LIB+= callouts/7.png IMAGES_LIB+= callouts/8.png IMAGES_LIB+= callouts/9.png IMAGES_LIB+= callouts/10.png IMAGES_LIB+= callouts/11.png IMAGES_LIB+= callouts/12.png IMAGES_LIB+= callouts/13.png IMAGES_LIB+= callouts/14.png IMAGES_LIB+= callouts/15.png # # SRCS lists the individual SGML files that make up the document. Changes # to any of these files will force a rebuild # # SGML content SRCS+= audit/chapter.sgml SRCS+= book.sgml SRCS+= colophon.sgml SRCS+= dtrace/chapter.sgml SRCS+= freebsd-glossary.sgml SRCS+= advanced-networking/chapter.sgml SRCS+= basics/chapter.sgml SRCS+= bibliography/chapter.sgml SRCS+= boot/chapter.sgml SRCS+= config/chapter.sgml SRCS+= cutting-edge/chapter.sgml SRCS+= desktop/chapter.sgml SRCS+= disks/chapter.sgml SRCS+= eresources/chapter.sgml SRCS+= firewalls/chapter.sgml SRCS+= filesystems/chapter.sgml SRCS+= geom/chapter.sgml SRCS+= install/chapter.sgml SRCS+= introduction/chapter.sgml SRCS+= jails/chapter.sgml SRCS+= kernelconfig/chapter.sgml SRCS+= l10n/chapter.sgml SRCS+= linuxemu/chapter.sgml SRCS+= mac/chapter.sgml SRCS+= mail/chapter.sgml SRCS+= mirrors/chapter.sgml SRCS+= multimedia/chapter.sgml SRCS+= network-servers/chapter.sgml SRCS+= pgpkeys/chapter.sgml SRCS+= ports/chapter.sgml SRCS+= ppp-and-slip/chapter.sgml SRCS+= preface/preface.sgml SRCS+= printing/chapter.sgml SRCS+= security/chapter.sgml SRCS+= serialcomms/chapter.sgml -SRCS+= updating/chapter.sgml SRCS+= users/chapter.sgml SRCS+= vinum/chapter.sgml SRCS+= virtualization/chapter.sgml SRCS+= x11/chapter.sgml # Entities SRCS+= chapters.ent SYMLINKS= ${DESTDIR} index.html handbook.html # Turn on all the chapters. CHAPTERS?= ${SRCS:M*chapter.sgml} SGMLFLAGS+= ${CHAPTERS:S/\/chapter.sgml//:S/^/-i chap./} SGMLFLAGS+= -i chap.freebsd-glossary pgpkeyring: pgpkeys/chapter.sgml @${JADE} -V nochunks ${OTHERFLAGS} ${JADEOPTS} -d ${DSLPGP} -t sgml ${MASTERDOC} DOC_PREFIX?= ${.CURDIR}/../../.. # # Handbook-specific variables # .if defined(WITH_PGPKEYS) JADEFLAGS+= -V withpgpkeys .endif URL_RELPREFIX?= ../../../.. DOC_PREFIX?= ${.CURDIR}/../../.. # # rules generating lists of mirror site from XML database. # XMLDOCS= mirrors-ftp:::mirrors.sgml.ftp.inc.tmp \ mirrors-cvsup:::mirrors.sgml.cvsup.inc.tmp \ eresources:::eresources.sgml.www.inc.tmp DEPENDSET.DEFAULT= transtable mirror XSLT.DEFAULT= ${XSL_MIRRORS} XML.DEFAULT= ${XML_MIRRORS} NO_TIDY.DEFAULT= yes PARAMS.mirrors-ftp+= --param 'type' "'ftp'" \ --param 'proto' "'ftp'" \ --param 'target' "'handbook/mirrors/chapter.sgml'" PARAMS.mirrors-cvsup+= --param 'type' "'cvsup'" \ --param 'proto' "'cvsup'" \ --param 'target' "'handbook/mirrors/chapter.sgml'" PARAMS.eresources+= --param 'type' "'www'" \ --param 'proto' "'http'" \ --param 'target' "'handbook/eresources/chapter.sgml'" SRCS+= mirrors.sgml.ftp.inc \ mirrors.sgml.cvsup.inc \ eresources.sgml.www.inc CLEANFILES+= mirrors.sgml.ftp.inc mirrors.sgml.ftp.inc.tmp \ mirrors.sgml.cvsup.inc mirrors.sgml.cvsup.inc.tmp \ eresources.sgml.www.inc eresources.sgml.www.inc.tmp .include "${DOC_PREFIX}/share/mk/doc.project.mk" .for p in ftp cvsup mirrors.sgml.${p}.inc: mirrors.sgml.${p}.inc.tmp ${SED} -e 's,<\([^ >]*\)\([^>]*\)/>,<\1\2>,;s,,,'\ < $@.tmp > $@ || (${RM} -f $@ && false) .endfor eresources.sgml.www.inc: eresources.sgml.www.inc.tmp ${SED} -e 's,<\([^ >]*\)\([^>]*\)/>,<\1\2>,;s,,,'\ < $@.tmp > $@ || (${RM} -f $@ && false) diff --git a/zh_CN.GB2312/books/handbook/advanced-networking/chapter.sgml b/zh_CN.GB2312/books/handbook/advanced-networking/chapter.sgml index 890e9e1a01..ed84ec9b24 100644 --- a/zh_CN.GB2312/books/handbook/advanced-networking/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/advanced-networking/chapter.sgml @@ -1,5167 +1,5167 @@ 高级网络 概述 本章将就一系列与网络有关的高级话题进行讨论。 读完这章,您将了解: 关于网关和路由的基础知识。 如何配置 IEEE 802.11 和 蓝牙(&bluetooth;) 设备。 如何用 FreeBSD 做网桥。 如何为无盘机上配置网络启动。 如何配置网络地址转换 (NAT)。 如何使用 PLIP 连接两台计算机。 如何在运行 FreeBSD 的计算机上配置 IPv6。 如何配置 ATM。 如何利用 CARP, &os; 支持的 Common Access Redundancy Protocol (共用地址冗余协议) 在读这章之前, 您应: 理解 /etc/rc 脚本的基本知识。 熟悉基本的网络术语。 了解如何配置和安装新的 FreeBSD 内核 ()。 了解如何安装第三方软件 ()。 Coranth Gryphon 贡献者: 雪平 中文翻译:
zxpmyth@yahoo.com.cn
苏义
网关和路由 路由 网关 子网 要让网络上的两台计算机能够相互通讯, 就必须有一种能够描述如何从一台计算机到另一台计算机的机制, 这一机制称作 路由选择(routing)路由项 是一对预先定义的地址: 目的地(destination)网关(gateway)。 这个地址对所表达的意义是, 通过 网关 能够完成与 目的地 的通信。 有三种类型的目的地址: 单个主机、 子网、 以及 默认。 如果没有可用的其它路由, 就会使用 默认路由, 有关默认路由的内容, 将在稍后的章节中进行讨论。 网关也有三种类型: 单个主机, 网络接口 (也叫 链路 (links)) 和以太网硬件地址 (MAC 地址)。 实例 为了说明路由选择的各个部分, 首先来看看下面的例子。 这是 netstat 命令的输出: &prompt.user; netstat -r Routing tables Destination Gateway Flags Refs Use Netif Expire default outside-gw UGSc 37 418 ppp0 localhost localhost UH 0 181 lo0 test0 0:e0:b5:36:cf:4f UHLW 5 63288 ed0 77 10.20.30.255 link#1 UHLW 1 2421 example.com link#1 UC 0 0 host1 0:e0:a8:37:8:1e UHLW 3 4601 lo0 host2 0:e0:a8:37:8:1e UHLW 0 5 lo0 => host2.example.com link#1 UC 0 0 224 link#1 UC 0 0 默认路由 头两行给出了当前配置中的默认路由 (将在 下一节 中进行介绍) 和 localhost (本机) 路由。 回环设备 这里的路由表中给出的用于 localhost 的接口 (Netif 列) 是 lo0, 也就是大家熟知的 回环设备。 它表示所有以此为 目的地 的通信都留在本机, 而不通过 LAN 发出, 因为这些流量最终会回到起点。 以太网 MAC 地址 接着出现的是以 0:e0: 开头的地址。这些是以太网硬件地址,也称为 MAC 地址。 FreeBSD 会自动识别在同一个以太网中的任何主机 (如 test0), 并为其新增一个路由, 并通过那个以太网接口 — ed0 直接与它通讯 (译者注:那台主机)。与这类路由表相关的也有一个超时项 (Expire列),当我们在指定时间内没有收到从那个主机发来的信息, 这项就派上用场了。这种情况下,到这个主机的路由就会被自动删除。 这些主机被使用一种叫做RIP(路由信息协议--Routing Information Protocol)的机制所识别,这种机制利用基于最短路径选择 (shortest path determination)的办法计算出到本地主机的路由。 子网 FreeBSD 也会为本地子网添加子网路由(10.20.30.255 是子网 10.20.30 的广播地址,而 example.com 是这个子网相联的域名)。 名称 link#1 代表主机上的第一块以太网卡。 您会发现,对于它们没有指定另外的接口。 这两个组(本地网络主机和本地子网)的路由是由守护进程 routed 自动配置的。如果它没有运行, 那就只有被静态定义 (例如,明确输入的) 的路由才存在了。 host1 行代表我们的主机,它通过以太网地址来识别。 因为我们是发送端,FreeBSD知道使用回环接口 (lo0) 而不是通过以太网接口来进行发送。 两个 host2 行是我们使用 &man.ifconfig.8; 别名 (请看关于以太网的那部分就会知道我们为什么这么做) 时产生的一个实例。在 lo0 接口之后的 => 符号表明我们不仅使用了回环 (因为这个地址也涉及了本地主机),而且明确指出它是个别名。 这类路由只有在支持别名的主机上才能显现出来。 所有本地网上的其它的主机对于这类路由只会简单拥有 link#1 最后一行 (目标子网224) 用于处理多播——它会覆盖到其它的区域。 最后,每个路由的不同属性可以在 Flags 列中看到。下边是个关于这些标志和它们的含义的一个简表: U Up: 路由处于活动状态。 H Host: 路由目标是单个主机。 G Gateway: 所有发到目的地的网络传到这一远程系统上, 并由它决定最后发到哪里。 S Static: 这个路由是手工配置的,不是由系统自动生成的。 C Clone: 生成一个新的路由, 通过这个路由我们可以连接上这些机子。 这种类型的路由通常用于本地网络。 W WasCloned: 指明一个路由——它是基于本地区域网络 (克隆) 路由自动配置的。 L Link: 路由涉及到了以太网硬件。 默认路由 默认路由 当本地系统需要与远程主机建立连接时, 它会检查路由表以决定是否有已知的路径存在。 如果远程主机属于一个我们已知如何到达 (克隆的路由) 的子网内,那么系统会检查看沿着那个接口是否能够连接。 如果所有已知路径都失败,系统还有最后一个选择: 默认路由。这个路由是特殊类型的网关路由 (通常只有一个存在于系统里),并且总是在标志栏使用一个 c来进行标识。对于本地区域网络里的主机, 这个网关被设置到任何与外界有直接连接的机子里 (无论是通过 PPP、DSL、cable modem、T1 或其它的网络接口连接)。 如果您正为某台本身就做为网关连接外界的机子配置默认路由的话, 那么该默认路由应该是您的互联网服务商 (ISP)那方的网关机子。 让我们来看一个关于默认路由的例子。这是个很普遍的配置: [Local2] <--ether--> [Local1] <--PPP--> [ISP-Serv] <--ether--> [T1-GW] 主机 Local1Local2 在您那边。Local1 通过 PPP 拨号连接到了 ISP。这个 PPP 服务器通过一个局域网连接到另一台网关机子——它又通过一个外部接口连接到 ISP 提供的互联网上。 您的每一台机子的默认路由应该是: Host Default Gateway Interface Local2 Local1 Ethernet Local1 T1-GW PPP 一个常见的问题是我们为什么 (或怎样) 能将 T1-GW 设置成为 Local1 默认网关,而不是它所连接 ISP 服务器? 记住,因为 PPP 接口使用的一个地址是在 ISP 的局域网里的,用于您那边的连接,对于 ISP 的局域网里的其它机子,其路由会自动产生。 因此,您就已经知道了如何到达机子 T1-GW, 那么也就没必要中那一步了——发送通信给 ISP 服务器。 通常使用地址 X.X.X.1 做为一个局域网的网关。 因此 (使用相同的例子),如果您本地的 C 类地址空间是 10.20.30,而您的 ISP 使用的是 10.9.9, 那么默认路由表将是: Host Default Route Local2 (10.20.30.2) Local1 (10.20.30.1) Local1 (10.20.30.1, 10.9.9.30) T1-GW (10.9.9.1) 您可以很轻易地通过 /etc/rc.conf 文件设定默认路由。在我们的实例里,在主机 Local2 里,我们在文件 /etc/rc.conf 里增加了下边内容: defaultrouter="10.20.30.1" 也可以直接在命令行使用 &man.route.8; 命令: &prompt.root; route add default 10.20.30.1 要了解关于如何手工维护网络路由表的进一步细节, 请参考 &man.route.8; 联机手册。 - + 重宿主机(Dual Homed Hosts) + 重宿 主机 还有一种其它的类型的配置是我们要提及的, 这就是一个主机处于两个不同的网络。技术上,任何作为网关 (上边的实例中,使用了 PPP 连接) 的机子就算作是重宿主机。 但这个词实际上仅用来指那种处于两个局域网之中的机子。 有一种情形,一台机子有两个网卡, 对于各个子网都有各自的一个地址。另一种情况, 这台机子仅有一张网卡,但使用 &man.ifconfig.8; 做了别名。如果有两个独立的以太网在使用的情形就使用前者, 如果只有一个物理网段,但逻辑上分成了两个独立的子网, 就使用后者。 每种情况都要设置路由表以便两子网都知道这台主机是到其它子网的网关——入站路由 (inbound route)。将一台主机配置成两个子网间的路由器, 这种配置经常在我们需要实现单向或双向的包过滤或防火墙时被用到。 如果想让主机在两个接口间转发数据包,您需要激活 FreBSD 的这项功能。至于怎么做,请看下一部分了解更多。 建立路由器 路由器 网络路由器只是一个将数据包从一个接口转发到另一个接口的系统。 互联网标准和良好的工程实践阻止了 FreeBSD 计划在 FreeBSD 中把它置成默认值。您在可以在 &man.rc.conf.5; 中改变下列变量的值为 YES,使这个功能生效: gateway_enable=YES # Set to YES if this host will be a gateway 这个选项会把&man.sysctl.8; 变量——net.inet.ip.forwarding 设置成 1。如果您要临时地停止路由, 您可以把它重设为 0 + BGP + RIP + OSPF 新的路由器需要有路由才知道将数据传向何处。 如果网络够简单,您可以使用静态路由。FreeBSD 也自带一个标准的BSD路由选择守护进程 &man.routed.8;, 称之为 RIP ( version 1和 version 2) 和 IRDP。对 BGP v4,OSPF v2 和其它复杂路由选择协议的支持可以从 net/zebra 包中得到。 像 &gated; 一样的商业产品也提供了更复杂的网络路由解决方案。 - -BGP -RIP -OSPF - + Coranth Gryphon 贡献者: 雪平 中文翻译:
zxpmyth@yahoo.com.cn
苏义
设置静态路由 手动配置 假设如下这样一个网络: INTERNET | (10.0.0.1/24) Default Router to Internet | |Interface xl0 |10.0.0.10/24 +------+ | | RouterA | | (FreeBSD gateway) +------+ | Interface xl1 | 192.168.1.1/24 | +--------------------------------+ Internal Net 1 | 192.168.1.2/24 | +------+ | | RouterB | | +------+ | 192.168.2.1/24 | Internal Net 2 在这里,RouterA 是我们的 &os; 机子,它充当连接到互联网其它部分的路由器的角色。 默认路由设置为10.0.0.1, 它就允许与外界连接。我们假定已经正确配置了 RouterB,并且知道如何连接到想去的任何地方。 (在这个图里很简单。只须在 RouterB 上增加默认路由,使用 192.168.1.1 做为网关。) 如果我们查看一下RouterA的路由表, 我们就会看到如下一些内容: &prompt.user; netstat -nr Routing tables Internet: Destination Gateway Flags Refs Use Netif Expire default 10.0.0.1 UGS 0 49378 xl0 127.0.0.1 127.0.0.1 UH 0 6 lo0 10.0.0/24 link#1 UC 0 0 xl0 192.168.1/24 link#2 UC 0 0 xl1 使用当前的路由表,RouterA 是不能到达我们的内网——Internal Net 2 的。它没有到 192.168.2.0/24 的路由。 一种可以接受的方法是手工增加这条路由。以下的命令会把 Internal Net 2 网络加入到 RouterA 的路由表中,使用192.168.1.2 做为下一个跳跃: &prompt.root; route add -net 192.168.2.0/24 192.168.1.2 现在 RouterA 就可以到达 192.168.2.0/24 网络上的任何主机了。 永久配置 上面的实例对于运行着的系统来说配置静态路由是相当不错了。 只是,有一个问题——如果您重启您的 &os; 机子,路由信息就会消失。 处理附加的静态路由的方法是把它放到您的 /etc/rc.conf 文件里去。 # Add Internal Net 2 as a static route static_routes="internalnet2" route_internalnet2="-net 192.168.2.0/24 192.168.1.2" 配置变量 static_routes 是一串以空格格开的字符串。每一串表示一个路由名字。 在上面的例子中我们中有一个串在 static_routes 里。这个字符串中 internalnet2。 然后我们新增一个配置变量 route_internalnet2, 这里我们把所有传给 &man.route.8;命令的参数拿了过来。 在上面的实例中的我使用的命令是: &prompt.root; route add -net 192.168.2.0/24 192.168.1.2 因此,我们需要的是 "-net 192.168.2.0/24 192.168.1.2" 前边已经提到, 可以把多个静态路由的名称, 放到 static_routes 里边。 接着我们就来建立多个静态路由。 下面几行所展示的, 是在一个假想的路由器上增加 192.168.0.0/24192.168.1.0/24 之间静态路由的例子: static_routes="net1 net2" route_net1="-net 192.168.0.0/24 192.168.0.1" route_net2="-net 192.168.1.0/24 192.168.1.1"
- + 路由传播 路由 传播 我们已经讨论了如何定义通向外界的路由, 但未谈及外界是如何找到我们的。 我们已经知道可以设置路由表, 这样任何指向特定地址空间 (在我们的例子中是一个 C 类子网) 的数据都会被送往网络上特定的主机, 然后由这台主机向地址空间内部转发数据。 当您得到一个分配给您的网络的地址空间时, ISP(网络服务商)会设置它们的路由表, 这样指向您子网的数据就会通过 PPP 连接下传到您的网络。 但是其它跨越国界的网络是如何知道将数据传给您的 ISP 的呢? 有一个系统(很像分布式 DNS 信息系统), 它一直跟踪被分配的地址空间, 并说明它们连接到互联网骨干(Internet backbone)的点。 骨干(Backbone) 指的是负责全世界和跨国的传输的主要干线。 每一台骨干主机(backbone machine)有一份主要表集的副本, 它将发送给特定网络的数据导向相应的骨干载体上(backbone carrier), 从结点往下遍历服务提供商链,直到数据到达您的网络。 服务提供商的任务是向骨干网络广播,以声明它们就是通向您的网点的连接结点 (以及进入的路径)。这就是路由传播。 - + 问题解答 traceroute 有时候,路由传播会有一个问题,一些网络无法与您连接。 或许能帮您找出路由是在哪里中断的最有用的命令就是 &man.traceroute.8;了。当您无法与远程主机连接时, 这个命令一样有用(例如 &man.ping.8; 失败)。 &man.traceroute.8; 命令将以您想连接的主机的名字作为参数执行。 不管是到达了目标,还是因为没有连接而终止, 它都会显示所经过的所有网关主机。 想了解更多的信息,查看 &man.traceroute.8; 的手册。 - + 多播路由 多播路由 内核选项 MROUTING FreeBSD 一开始就支持多播应用软件和多播路由选择。 多播程序并不要求FreeBSD的任何特殊的配置, 就可以工作得很好。多播路由需要支持被编译入内核: options MROUTING 另外,多播路由守护进程——&man.mrouted.8; 必须通过 /etc/mrouted.conf 配置来开启通道和 DVMRP。 更多关于多播路由配置的信息可以在 &man.mrouted.8; 的手册里找到。 &os; 7.0 开始 &man.mrouted.8; 多播路由守护进程已从基本系统中移除。 实现 DVMRP 多播路由协议的程序主要由 &man.pim.4; 取代。相关的 &man.map-mbone.8; 和 &man.mrinfo.8 工具也被移除了。 这些程序能在 &os; 的 Ports Collection net/mrouted 中找到。
陈福康 Marc Fonvieille Murray Stokely 无线网络 wireless networking (无线网络) 802.11 wireless networking (无线网络) 无线网络基础 绝大多数无线网络都采用了 IEEE 802.11 标准。 基本的无线网络中, 都包含多个以 2.4GHz 或 5GHz 频段的无线电波广播的站点 (不过, 随所处地域的不同, 或者为了能够更好地进行通讯, 具体的频率会在 2.3GHz 和 4.9GHz 的范围内变化)。 802.11 网络有两种组织方式: 在 infrastructure 模式 中, 一个通讯站作为主站, 其他通讯站都与其关联; 这种网络称为 BSS, 而主站则成为无线访问点 (AP)。 在 BSS 中, 所有的通讯都是通过 AP 来完成的; 即使通讯站之间要相互通讯, 也必须将消息发给 AP。 在第二种形式的网络中, 并不存在主站, 通讯站之间是直接通讯的。 这种网络形式称作 IBSS, 通常也叫做 ad-hoc 网络 802.11 网络最初在 2.4GHz 频段上部署, 并采用了由 IEEE 802.11 和 802.11b 标准所定义的协议。 这些标准定义了采用的操作频率、 包括分帧和传输速率 (通讯过程中可以使用不同的速率) 在内的 MAC 层特性等。 稍后的 802.11a 标准定义了使用 5GHz 频段进行操作, 以及不同的信号机制和更高的传输速率。 其后定义的 802.11g 标准启用了在 2.4GHz 上如何使用 802.11a 信号和传输机制, 以提供对较早的 802.11b 网络的向前兼容。 802.11 网络中采用的各类底层传输机制提供了不同类型的安全机制。 最初的 802.11 标准定义了一种称为 WEP 的简单安全协议。 这个协议采用固定的预发布密钥, 并使用 RC4 加密算法来对在网络上传输的数据进行编码。 全部通讯站都必须采用同样的固定密钥才能通讯。 这一格局已经被证明很容易被攻破, 因此目前已经很少使用了, 采用这种方法只能让那些接入网络的用户迅速断开。 最新的安全实践是由 IEEE 802.11i 标准给出的, 它定义了新的加密算法, 并通过一种附加的协议来让通讯站向无线访问点验证身份, 并交换用于进行数据通讯的密钥。 更进一步, 用于加密的密钥会定期地刷新, 而且有机制能够监测入侵的尝试 (并阻止这种尝试)。 无线网络中另一种常用的安全协议标准是 WPA。 这是在 802.11i 之前由业界组织定义的一种过渡性标准。 WPA 定义了在 802.11i 中所规定的要求的子集, 并被设计用来在旧式硬件上实施。 特别地, WPA 要求只使用由最初 WEP 所采用的算法派生的 TKIP 加密算法。 802.11i 则不但允许使用 TKIP, 而且还要求支持更强的加密算法 AES-CCM 来用于加密数据。 (在 WPA 中并没有要求使用 AES 加密算法, 因为在旧式硬件上实施这种算法时所需的计算复杂性太高。) 除了前面介绍的那些协议标准之外, 还有一种需要介绍的标准是 802.11e。 它定义了用于在 802.11 网络上运行多媒体应用, 如视频流和使用 IP 传送的语音 (VoIP) 的协议。 与 802.11i 类似, 802.11e 也有一个前身标准, 通常称作 WME (后改名为 WMM), 它也是由业界组织定义的 802.11e 的子集, 以便能够在旧式硬件中使用多媒体应用。 关于 802.11e 与 WME/WMM 之间的另一项重要区别是, 前者允许对流量通过服务品质 (QoS) 协议和增强媒体访问协议来安排优先级。 对于这些协议的正确实现, 能够实现高速突发数据和流量分级。 从 6.0 版本开始, &os; 支持采用 802.11a, 802.11b 和 802.11g 的网络。 类似地, 它也支持 WPA 和 802.11i 安全协议 (与 11a、 11b 和 11g 配合), 而 WME/WMM 所需要的 QoS 和流量分级, 则在部分无线设备上提供了支持。 基本安装 内核配置 要使用无线网络, 您需要一块无线网卡, 并适当地配置内核令其提供无线网络支持。 后者被分成了多个模块, 因此您只需配置使用您所需要的软件就可以了。 首先您需要的是一个无线设备。 最为常用的一种无线配件是 Atheros 生产的。 这些设备由 &man.ath.4; 驱动程序提供支持, 您需要把下面的配置加入到 /boot/loader.conf 文件中: if_ath_load="YES" Atheros 驱动分为三个部分: 驱动部分 (&man.ath.4;)、 用于处理芯片专有功能的支持层 (&man.ath.hal.4;), 以及一组用以选择传输帧速率的算法 (ath_rate_sample here)。 当以模块方式加载这一支持时, 所需的其它模块会自动加载。 如果您使用的不是 Atheros 设备, 则应选择对应的模块; 例如: if_wi_load="YES" 表示使用基于 Intersil Prism 产品的无线设备 (&man.wi.4; 驱动)。 在这篇文挡余下的部分中, 我们将使用一张 &man.ath.4; 卡作示范, 如果您要套用这些配置的话, 就必须根据实际的配置情况来替换设备名。 在联机手册 &man.wlan.4; 的开头部分给出了一份可用的驱动列表。 如果您的无线设备没有专用于 &os; 的驱动程序, 也可以尝试使用 NDIS 驱动封装机制来直接使用 &windows; 驱动。 在配置好设备驱动之后, 您还需要引入驱动程序所需要的 802.11 网络支持。 对于 &man.ath.4; 驱动而言, 至少需要 &man.wlan.4; wlan_scan_apwlan_scan_sta 模块; &man.wlan.4; 模块会自动随无线设备驱动一同加载, 剩下的模块必须要在系统引导时加载, 就需要在 /boot/loader.conf 中加入下面的配置: wlan_scan_ap_load="YES" wlan_scan_sta_load="YES" 除此之外, 您还需要提供您希望使用的安全协议所需的加密支持模块。 这些模块是设计来让 &man.wlan.4; 模块根据需要自动加载的, 但目前还必须手工进行配置。 您可以使用下面这些模块: &man.wlan.wep.4;、 &man.wlan.ccmp.4; 和 &man.wlan.tkip.4;。 &man.wlan.ccmp.4; 和 &man.wlan.tkip.4; 这两个驱动都只有在您希望采用 WPA 和/或 802.11i 安全协议时才需要。 如果您的网络是完全开放的 (也就是不加密) 则甚至连 &man.wlan.wep.4; 支持也是不需要的。 要在系统引导时加载这些模块, 就需要在 /boot/loader.conf 中加入下面的配置: wlan_wep_load="YES" wlan_ccmp_load="YES" wlan_tkip_load="YES" 通过系统引导配置文件 (也就是 /boot/loader.conf) 中的这些信息生效, 您必须重新启动运行 &os; 的计算机。 如果不想立刻重新启动, 也可以使用 &man.kldload.8; 来手工加载。 如果不想加载模块, 也可以将这些驱动编译到内核中, 方法是在内核的编译配置文件中加入下面的配置: device ath # Atheros IEEE 802.11 wireless network driver device ath_hal # Atheros Hardware Access Layer device ath_rate_sample # John Bicket's SampleRate control algorithm. device wlan # 802.11 support (Required) device wlan_scan_ap # 802.11 AP mode scanning device wlan_scan_sta # 802.11 STA mode scanning device wlan_wep # WEP crypto support for 802.11 devices device wlan_ccmp # AES-CCMP crypto support for 802.11 devices device wlan_tkip # TKIP and Michael crypto support for 802.11 devices 将这些信息写到内核编译配置文件中之后, 您需要重新编译内核, 并重新启动运行 &os; 的计算机。 在系统启动之后, 您会在引导时给出的信息中, 找到类似下面这样的关于无线设备的信息: ath0: <Atheros 5212> mem 0xff9f0000-0xff9fffff irq 17 at device 2.0 on pci2 ath0: Ethernet address: 00:11:95:d5:43:62 ath0: mac 7.9 phy 4.5 radio 5.6 Infrastructure 模式 通常的情形中使用的是 infrastructure 模式或称 BSS 模式。 在这种模式中, 有一系列无线访问点接入了有线网络。 每个无线网都会有自己的名字, 这个名字称作网络的 SSID。 无线客户端都通过无线访问点来完成接入。 &os; 客户机 如何查找无线访问点 您可以通过使用 ifconfig 命令来扫描网络。 由于系统需要在操作过程中切换不同的无线频率并探测可用的无线访问点, 这种请求可能需要数分钟才能完成。 只有超级用户才能启动这种扫描: &prompt.root; ifconfig ath0 up scan SSID BSSID CHAN RATE S:N INT CAPS dlinkap 00:13:46:49:41:76 6 54M 29:3 100 EPS WPA WME freebsdap 00:11:95:c3:0d:ac 1 54M 22:1 100 EPS WPA 在开始扫描之前, 必须将网络接口设为 。 后续的扫描请求就不需要再将网络接口设为 up 了。 扫描会列出所请求到的所有 BSS/IBSS 网络列表。 除了网络的名字 SSID 之外, 我们还会看到 BSSID 即无线访问点的 MAC 地址。 而 CAPS 字段则给出了网络类型及其提供的功能, 其中包括: E Extended Service Set (ESS)。 表示通讯站是 infrastructure 网络 (相对于 IBSS/ad-hoc 网络) 的成员。 I IBSS/ad-hoc 网络。 表示通讯站是 ad-hoc 网络 (相对于 ESS 网络) 的成员。 P 私密。 在 BSS 中交换的全部数据帧均需保证数据保密性。 这表示 BSS 需要通讯站使用加密算法, 例如 WEP、 TKIP 或 AES-CCMP 来加密/解密与其他通讯站交换的数据帧。 S 短前导码 (Short Preamble)。 表示网络采用的是短前导码 (由 802.11b High Rate/DSSS PHY 定义, 短前导码采用 56-位 同步字段, 而不是在长前导码模式中所采用的 128-位 字段)。 s 短碰撞槽时间 (Short slot time)。 表示由于不存在旧式 (802.11b) 通讯站, 802.11g 网络正使用短碰撞槽时间。 要显示目前已知的网络, 可以使用下面的命令: &prompt.root; ifconfig ath0 list scan 这些信息可能会由无线适配器自动更新, 也可使用 手动更新。 快取缓存中的旧数据会自动删除, 因此除非进行更多扫描, 这个列表会逐渐缩小。 基本配置 在这一节中我们将展示一个简单的例子来介绍如何让无线网络适配器在 &os; 中以不加密的方式工作。 在您熟悉了这些概念之后, 我们强烈建议您在实际的使用中采用 WPA 来配置网络。 配置无线网络的过程可分为三个基本步骤: 选择无线访问点、 验证您的通讯站身份, 以及配置 IP 地址。 下面的几节中将分步骤地介绍它们。 选择无线访问点 多数时候让系统以内建的探测方式选择无线访问点就可以了。 这是在您将网络接口置为 up 或在 /etc/rc.conf 中配置 IP 地址时的默认方式, 例如: ifconfig_ath0="DHCP" 如果存在多个无线访问点, 而您希望从中选择具体的一个, 则可以通过指定 SSID 来实现: ifconfig_ath0="ssid your_ssid_here DHCP" 在某些环境中, 多个访问点可能会使用同样的 SSID (通常, 这样做的目的是简化漫游), 这时可能就需要与某个具体的设备关联了。 这种情况下, 您还应指定无线访问点的 BSSID (这时可以不指定 SSID): ifconfig_ath0="ssid your_ssid_here bssid xx:xx:xx:xx:xx:xx DHCP" 除此之外, 还有一些其它的方法能够约束查找无线访问点的范围, 例如限制系统扫描的频段, 等等。 如果您的无线网卡支持多个频段, 这样做可能会非常有用, 因为扫描全部可用频段是一个十分耗时的过程。 要将操作限制在某个具体的频段, 可以使用 参数; 例如: ifconfig_ath0="mode 11g ssid your_ssid_here DHCP" 就会强制卡使用采用 2.4GHz 的 802.11g, 这样在扫描的时候, 就不会考虑那些 5GHz 的频段了。 除此之外, 还可以通过 参数来将操作锁定在特定频率, 以及通过 参数来指定扫描的频段列表。 关于这些参数的进一步信息, 可以在联机手册 &man.ifconfig.8; 中找到。 验证身份 一旦您选定了无线访问点, 您的通讯站就需要完成身份验证, 以便开始发送和接收数据。 身份验证可以通过许多方式进行, 最常用的一种方式称为开放式验证, 它允许任意通讯站加入网络并相互通信。 这种验证方式只应在您第一次配置无线网络进行测试时使用。 其它的验证方式则需要在进行数据通讯之前, 首先进行密钥协商握手; 这些方式要么使用预先分发的密钥或密码, 要么是用更复杂一些的后台服务, 如 RADIUS。 绝大多数用户会使用默认的开放式验证, 而第二多的则是 WPA-PSK, 它也称为个人 WPA, 在 下面 的章节中将进行介绍。 如果您使用 &apple; &airport; Extreme 基站作为无线访问点, 则可能需要同时在两端配置 WEP 共享密钥验证。 这可以通过在 /etc/rc.conf 文件中进行设置, 或使用 &man.wpa.supplicant.8; 程序来手工完成。 如果您只有一个 &airport; 基站, 则可以用类似下面的方法来配置: ifconfig_ath0="authmode shared wepmode on weptxkey 1 wepkey 01234567 DHCP" 一般而言, 应尽量避免使用共享密钥这种验证方法, 因为它以非常受限的方式使用 WEP 密钥, 使得攻击者能够很容易地破解密钥。 如果必须使用 WEP (例如, 为了兼容旧式的设备) 最好使用 WEP 配合 open 验证方式。 关于 WEP 的更多资料请参见 通过 DHCP 获取 IP 地址 在您选定了无线访问点, 并配置了验证参数之后, 还必须获得 IP 地址才能真正开始通讯。 多数时候, 您会通过 DHCP 来获得无线 IP 地址。 要达到这个目的, 只需简单地编辑 /etc/rc.conf 并在配置中加入 DHCP ifconfig_ath0="DHCP" 现在您已经完成了启用无线网络接口的全部准备工作了, 下面的操作将启用它: &prompt.root; /etc/rc.d/netif start 一旦网络接口开始运行, 就可以使用 ifconfig 来查看网络接口 ath0 的状态了: &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.1.100 netmask 0xffffff00 broadcast 192.168.1.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (OFDM/54Mbps) status: associated ssid dlinkap channel 6 bssid 00:13:46:49:41:76 authmode OPEN privacy OFF txpowmax 36 protmode CTS bintval 100 这里的 status: associated 表示您已经连接到了无线网络 (在这个例子中, 这个网络的名字是 dlinkap)。 bssid 00:13:46:49:41:76 是指您所用无线访问点的 MAC 地址; authmode 这行指出您所做的通讯将不进行加密 (OPEN)。 静态 IP 地址 如果无法从某个 DHCP 服务器获得 IP 地址, 则可以配置一个静态 IP 地址, 方法是将前面的 DHCP 关键字替换为地址信息。 请务必保持其他用于连接无线访问点的参数: ifconfig_ath0="ssid your_ssid_here inet 192.168.1.100 netmask 255.255.255.0" WPA WPA (Wi-Fi 保护访问) 是一种与 802.11 网络配合使用的安全协议, 其目的是消除 WEP 中缺少身份验证能力的问题, 以及一些其它的安全弱点。 WPA 采用了 802.1X 认证协议, 并采用从多种与 WEP 不同的加密算法中选择一种来保证数据保密性。 WPA 支持的唯一一种加密算法是 TKIP (临时密钥完整性协议), 这是一种对 WEP 所采用的基本 RC4 加密算法的扩展, 除此之外还提供了对检测到的入侵的响应机制。 TKIP 被设计用来与旧式硬件一同工作, 只需要进行部分软件修改; 它提供了一种改善安全性的折衷方案, 但仍有可能受到攻击。 WPA 也指定了 AES-CCMP 加密作为 TKIP 的替代品, 在可能时倾向于使用这种加密; 表达这一规范的常用术语是 WPA2 (或 RSN)。 WPA 定义了验证和加密协议。 验证通常是使用两种方法之一来完成的: 通过 802.1X 或类似 RADIUS 这样的后端验证服务, 或通过在通讯站和无线访问点之间通过事先分发的密码来进行最小握手。 前一种通常称作企业 WPA, 而后者通常也叫做个人 WPA。 因为多数人不会为无线网络配置 RADIUS 后端服务器, 因此 WPA-PSK 是在 WPA 中最为常见的一种。 对无线连接的控制和身份验证工作 (密钥协商或通过服务器验证) 是通过 &man.wpa.supplicant.8; 工具来完成的。 这个程序运行时需要一个配置文件, /etc/wpa_supplicant.conf。 关于这个文件的更多信息, 请参考联机手册 &man.wpa.supplicant.conf.5;。 WPA-PSK WPA-PSK 也称作 个人-WPA, 它基于预先分发的密钥 (PSK), 这个密钥是根据作为无线网络上使用的主密钥的密码生成的。 这表示每个无线用户都会使用同样的密钥。 WPA-PSK 主要用于小型网络, 在这种网络中, 通常不需要或没有办法架设验证服务器。 无论何时, 都应使用足够长, 且包括尽可能多字母和数字的强口令, 以免被猜出和/或攻击。 第一步是修改配置文件 /etc/wpa_supplicant.conf, 并在其中加入在您网络上使用的 SSID 和事先分发的密钥: network={ ssid="freebsdap" psk="freebsdmall" } 接下来, 在 /etc/rc.conf 中, 我们将指定无线设备的配置, 令其采用 WPA, 并通过 DHCP 来获取 IP 地址: ifconfig_ath0="WPA DHCP" 下面, 启用无线网络接口: &prompt.root; /etc/rc.d/netif start Starting wpa_supplicant. DHCPDISCOVER on ath0 to 255.255.255.255 port 67 interval 5 DHCPDISCOVER on ath0 to 255.255.255.255 port 67 interval 6 DHCPOFFER from 192.168.0.1 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPACK from 192.168.0.1 bound to 192.168.0.254 -- renewal in 300 seconds. ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.254 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (OFDM/36Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA privacy ON deftxkey UNDEF TKIP 2:128-bit txpowmax 36 protmode CTS roaming MANUAL bintval 100 除此之外, 您也可以手动地使用 above 中那份 /etc/wpa_supplicant.conf 来配置, 方法是执行: &prompt.root; wpa_supplicant -i ath0 -c /etc/wpa_supplicant.conf Trying to associate with 00:11:95:c3:0d:ac (SSID='freebsdap' freq=2412 MHz) Associated with 00:11:95:c3:0d:ac WPA: Key negotiation completed with 00:11:95:c3:0d:ac [PTK=TKIP GTK=TKIP] 接下来的操作, 是运行 dhclient 命令来从 DHCP 服务器获取 IP: &prompt.root; dhclient ath0 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPACK from 192.168.0.1 bound to 192.168.0.254 -- renewal in 300 seconds. &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.254 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (OFDM/48Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA privacy ON deftxkey UNDEF TKIP 2:128-bit txpowmax 36 protmode CTS roaming MANUAL bintval 100 如果 /etc/rc.conf 的配置中, 使用了 ifconfig_ath0="DHCP", 就不需要手工运行 dhclient 命令了, 因为 dhclient 将在 wpa_supplicant 探测到密钥之后执行。 在这个例子中, DHCP 并不可用, 您可以在 wpa_supplicant 为通讯站完成了身份认证之后, 指定静态 IP 地址: &prompt.root; ifconfig ath0 inet 192.168.0.100 netmask 255.255.255.0 &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.100 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (OFDM/36Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA privacy ON deftxkey UNDEF TKIP 2:128-bit txpowmax 36 protmode CTS roaming MANUAL bintval 100 如果没有使用 DHCP, 还需要手工配置默认网关, 以及域名服务器: &prompt.root; route add default your_default_router &prompt.root; echo "nameserver your_DNS_server" >> /etc/resolv.conf 使用 EAP-TLS 的 WPA 使用 WPA 的第二种方式是使用 802.1X 后端验证服务器, 在这个例子中, WPA 也称作 企业-WPA, 以便与安全性较差、 采用事先分发密钥的 个人-WPA 区分开来。 在 企业-WPA 中, 验证操作是采用 EAP 完成的 (可扩展认证协议)。 EAP 并未附带加密方法, 因此设计者决定将 EAP 放在加密信道中进行传送。 为此设计了许多 EAP 验证方法, 最常用的方法是 EAP-TLS、 EAP-TTLS 和 EAP-PEAP。 EAP-TLS (带 传输层安全 的 EAP) 是一种在无线世界中得到了广泛支持的验证协议, 因为它是 Wi-Fi 联盟 核准的第一个 EAP 方法。 EAP-TLS 需要使用三个证书: CA 证书 (在所有计算机上安装)、 用以向您证明服务器身份的服务器证书, 以及每个无线客户端用于证明身份的客户机证书。 在这种 EAP 方式中, 验证服务器和无线客户端均通过自己的证书向对方证明身份, 它们均验证对方的证书是本机构的证书发证机构 (CA) 签发的。 与之前介绍的方法类似, 配置也是通过 /etc/wpa_supplicant.conf 来完成的: network={ ssid="freebsdap" proto=RSN key_mgmt=WPA-EAP eap=TLS identity="loader" ca_cert="/etc/certs/cacert.pem" client_cert="/etc/certs/clientcert.pem" private_key="/etc/certs/clientkey.pem" private_key_passwd="freebsdmallclient" } 这个字段表示网络名 (SSID)。 这里, 我们使用 RSN (IEEE 802.11i) 协议, 也就是 WPA2。 key_mgmt 这行表示所用的密钥管理协议。 在我们的例子中, 它是使用 EAP 验证的 WPA: WPA-EAP 这个字段中, 提到了我们的连接采用 EAP 方式。 identity 字段包含了 EAP 的实体串。 ca_cert 字段给出了 CA 证书文件的路径名。 在验证服务器证书时, 这个文件是必需的。 client_cert 这行给出了客户机证书的路径名。 对每个无线客户端而言, 这个证书都是在全网范围内唯一的。 private_key 字段是客户机证书私钥文件的路径名。 private_key_passwd 字段是私钥的口令字。 接着, 把下面的配置加入到 /etc/rc.conf ifconfig_ath0="WPA DHCP" 下一步是使用 rc.d 机制来启用网络接口: &prompt.root; /etc/rc.d/netif start Starting wpa_supplicant. DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPACK from 192.168.0.20 bound to 192.168.0.254 -- renewal in 300 seconds. ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.254 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (DS/11Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA2/802.11i privacy ON deftxkey UNDEF TKIP 2:128-bit txpowmax 36 protmode CTS roaming MANUAL bintval 100 如前面提到的那样, 也可以手工通过 wpa_supplicantifconfig 命令达到类似的目的。 使用 EAP-TTLS 的 WPA 在使用 EAP-TLS 时, 参与验证过程的服务器和客户机都需要证书, 而在使用 EAP-TTLS (带传输层安全隧道的 EAP) 时, 客户机证书则是可选的。 这种方式与某些安全 web 站点更为接近, 即使访问者没有客户端证书, 这些 web 服务器也能建立安全的 SSL 隧道。 EAP-TTLS 会使用加密的 TLS 隧道来传送验证信息。 对于它的配置, 同样是通过 /etc/wpa_supplicant.conf 文件来进行的: network={ ssid="freebsdap" proto=RSN key_mgmt=WPA-EAP eap=TTLS identity="test" password="test" ca_cert="/etc/certs/cacert.pem" phase2="auth=MD5" } 这个字段是我们的连接所采用的 EAP 方式。 identity 字段中是在加密 TLS 隧道中用于 EAP 验证的身份串。 password 字段中是用于 EAP 验证的口令字。 ca_cert 字段给出了 CA 证书文件的路径名。 在验证服务器证书时, 这个文件是必需的。 这个字段中给出了加密 TLS 隧道中使用的验证方式。 在这个例子中, 我们使用的是带 MD5-加密口令 的 EAP。 inner authentication (译注:内部鉴定) 通常也叫 phase2 您还必须把下面的配置加入到 /etc/rc.conf ifconfig_ath0="WPA DHCP" 下一步是启用网络接口: &prompt.root; /etc/rc.d/netif start Starting wpa_supplicant. DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPACK from 192.168.0.20 bound to 192.168.0.254 -- renewal in 300 seconds. ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.254 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (DS/11Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA2/802.11i privacy ON deftxkey UNDEF TKIP 2:128-bit txpowmax 36 protmode CTS roaming MANUAL bintval 100 使用 EAP-PEAP 的 WPA PEAP (受保护的 EAP) 被设计用以替代 EAP-TTLS。 有两种类型的 PEAP 方法, 最常用的是 PEAPv0/EAP-MSCHAPv2。 在这篇文档余下的部分中, 术语 PEAP 是指这种 EAP 方法。 PEAP 是在 EAP-TLS 之后最为常用的 EAP 标准, 换言之, 如果您的网络中有多种不同的操作系统, PEAP 将是仅次于 EAP-TLS 的支持最广的标准。 PEAP 与 EAP-TTLS 很像: 它使用服务器端证书, 通过在客户端与验证服务器之间建立加密的 TLS 隧道来向用户验证身份, 这保护了验证信息的交换过程。 在安全方面, EAP-TTLS 与 PEAP 的区别是 PEAP 会以明文广播用户名, 只有口令是通过加密 TLS 隧道传送的。 而 EAP-TTLS 在传送用户名和口令时, 都使用 TLS 隧道。 我们需要编辑 /etc/wpa_supplicant.conf 文件, 并加入与 EAP-PEAP 有关的配置: network={ ssid="freebsdap" proto=RSN key_mgmt=WPA-EAP eap=PEAP identity="test" password="test" ca_cert="/etc/certs/cacert.pem" phase1="peaplabel=0" phase2="auth=MSCHAPV2" } 这个字段的内容是用于连接的 EAP 方式。 identity 字段中是在加密 TLS 隧道中用于 EAP 验证的身份串。 password 字段中是用于 EAP 验证的口令字。 ca_cert 字段给出了 CA 证书文件的路径名。 在验证服务器证书时, 这个文件是必需的。 这个字段包含了第一阶段验证 (TLS 隧道) 的参数。 随您使用的验证服务器的不同, 您需要指定验证的标签。 多数时候, 标签应该是 客户端 EAP 加密, 这可以通过使用 peaplabel=0 来指定。 更多信息可以在联机手册 &man.wpa.supplicant.conf.5; 中找到。 这个字段的内容是验证协议在加密的 TLS 隧道中使用的信息。 对 PEAP 而言, 这是 auth=MSCHAPV2 您还必须把下面的配置加入到 /etc/rc.conf ifconfig_ath0="WPA DHCP" 下一步是启用网络接口: &prompt.root; /etc/rc.d/netif start Starting wpa_supplicant. DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPREQUEST on ath0 to 255.255.255.255 port 67 DHCPACK from 192.168.0.20 bound to 192.168.0.254 -- renewal in 300 seconds. ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.254 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (DS/11Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA2/802.11i privacy ON deftxkey UNDEF TKIP 2:128-bit txpowmax 36 protmode CTS roaming MANUAL bintval 100 WEP WEP (有线等效协议) 是最初 802.11 标准的一部分。 其中没有提供身份验证机制, 只提供了弱访问控制, 而且很容易破解。 WEP 可以通过 ifconfig 配置: &prompt.root; ifconfig ath0 ssid my_net wepmode on weptxkey 3 wepkey 3:0x3456789012 \ inet 192.168.1.100 netmask 255.255.255.0 weptxkey 指明了使用哪个 WEP 密钥来进行数据传输。 这里我们使用第三个密钥。 它必须与无线接入点的配置一致。 如果你不清楚你的无线接入点, 你应该尝试用 1 (就是说第一个密钥)来设置这个变量。 wepkey 表示设置所选的 WEP 密钥。 其格式应为 index:key, 如果没有给出 index 值, 则默认为 1。 因此, 如果需要设置的密钥不是第一个, 就必需指定 index 了。 您需要将 0x3456789012 改为在无线接入点上配置的那个。 我们建议您阅读联机手册 &man.ifconfig.8; 来了解进一步的信息。 wpa_supplicant 机制也可以用来配置您的无线网卡使用 WEP。 前面的例子也可以通过在 /etc/wpa_supplicant.conf 中加入下述设置来实现: network={ ssid="my_net" key_mgmt=NONE wep_key3=3456789012 wep_tx_keyidx=3 } 接着: &prompt.root; wpa_supplicant -i ath0 -c /etc/wpa_supplicant.conf Trying to associate with 00:13:46:49:41:76 (SSID='dlinkap' freq=2437 MHz) Associated with 00:13:46:49:41:76 Ad-hoc 模式 IBSS 模式, 也称为 ad-hoc 模式, 是为点对点连接设计的。 例如, 如果希望在计算机 AB 之间建立 ad-hoc 网络, 我们只需选择两个 IP 地址和一个 SSID 就可以了。 在计算机 A 上: &prompt.root; ifconfig ath0 ssid freebsdap mediaopt adhoc inet 192.168.0.1 netmask 255.255.255.0 &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet 192.168.0.1 netmask 0xffffff00 broadcast 192.168.0.255 inet6 fe80::211:95ff:fec3:dac%ath0 prefixlen 64 scopeid 0x4 ether 00:11:95:c3:0d:ac media: IEEE 802.11 Wireless Ethernet autoselect <adhoc> (autoselect <adhoc>) status: associated ssid freebsdap channel 2 bssid 02:11:95:c3:0d:ac authmode OPEN privacy OFF txpowmax 36 protmode CTS bintval 100 此处的 adhoc 参数表示无线网络接口应以 IBSS 模式运转。 此时, 在 B 上应该能够检测到 A 的存在了: &prompt.root; ifconfig ath0 up scan SSID BSSID CHAN RATE S:N INT CAPS freebsdap 02:11:95:c3:0d:ac 2 54M 19:3 100 IS 在输出中的 I 再次确认了 A 机是以 ad-hoc 模式运行的。 我们只需给 B 配置一不同的 IP 地址: &prompt.root; ifconfig ath0 ssid freebsdap mediaopt adhoc inet 192.168.0.2 netmask 255.255.255.0 &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.2 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect <adhoc> (autoselect <adhoc>) status: associated ssid freebsdap channel 2 bssid 02:11:95:c3:0d:ac authmode OPEN privacy OFF txpowmax 36 protmode CTS bintval 100 这样, AB 就可以交换信息了。 &os; 基于主机的(无线)访问接入点 &os; 可以作为一个(无线)访问接入点(AP), 这样可以不必再去买一个硬件 AP 或者使用 ad-hoc 模式的网络。 当你的 &os; 机器作为网关连接到另外一个网络的时候将非常有用。 基本配置 在把你的 &os; 机器配置成一个 AP 以前, 你首先需要先在内核配置好对你的无线网卡的无线网络支持。 当然你还需要加上你想用的安全协议。想获得更详细的信息, 请参阅 目前还不支持使用 &windows; 驱动和 NDIS 驱动包装的网卡做为 AP 使用。只有 &os; 原生的无线驱动能够支持 AP 模式。 一旦装载了无线网络的支持, 你就可以检查一下看看你的无线设备是否支持基于主机的无线访问接入模式 (通常也被称为 hostap 模式): &prompt.root; ifconfig ath0 list caps ath0=783ed0f<WEP,TKIP,AES,AES_CCM,IBSS,HOSTAP,AHDEMO,TXPMGT,SHSLOT,SHPREAMBLE,MONITOR,TKIPMIC,WPA1,WPA2,BURST,WME> 这段输出显示了网卡所支持的各种功能; 其中的关键字 HOSTAP 表示这块无线网卡能作为一个(无线)访问接入点使用。 同时也提到了各种加密算法: WEP,TKIP,WPA2,等等, 这些信息对于知道在访问接入点上使用何种安全协议非常重要。 现在这块无线设备在配置了正确的 SSID 和 IP 地址后进入 hostap 模式了。 &prompt.root; ifconfig ath0 ssid freebsdap mode 11g mediaopt hostap inet 192.168.0.1 netmask 255.255.255.0 再一次用 ifconfig 查看一下 ath0 网络接口的状态: &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet 192.168.0.1 netmask 0xffffff00 broadcast 192.168.0.255 inet6 fe80::211:95ff:fec3:dac%ath0 prefixlen 64 scopeid 0x4 ether 00:11:95:c3:0d:ac media: IEEE 802.11 Wireless Ethernet autoselect mode 11g <hostap> status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode OPEN privacy OFF txpowmax 38 bmiss 7 protmode CTS burst dtimperiod 1 bintval 100 hostap 参数说明这个网络接口目前正运行在基于主机的接入访问模式。 也可以在 /etc/rc.conf 中加入以下这行使得网络界面的配置能够在机器启动的时候自动完成: ifconfig_ath0="ssid freebsdap mode 11g mediaopt hostap inet 192.168.0.1 netmask 255.255.255.0" 不使用认证或加密的(无线)访问接入点 尽管我们不推荐运行一个不使用任何认证或加密的 AP, 但这是一个非常简单的检测 AP 是否正常工作的方法。 这样配置对于调试客户端问题也非常重要。 一旦 AP 被配置成了我们前面所展示的那样, 就可以在另外一台无线机器上初始化一次扫描来找到这个 AP: &prompt.root; ifconfig ath0 up scan SSID BSSID CHAN RATE S:N INT CAPS freebsdap 00:11:95:c3:0d:ac 1 54M 22:1 100 ES 在客户机上能看到已经连接上了(无线)访问接入点: &prompt.root; ifconfig ath0 ssid freebsdap inet 192.168.0.2 netmask 255.255.255.0 &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet6 fe80::211:95ff:fed5:4362%ath0 prefixlen 64 scopeid 0x1 inet 192.168.0.2 netmask 0xffffff00 broadcast 192.168.0.255 ether 00:11:95:d5:43:62 media: IEEE 802.11 Wireless Ethernet autoselect (OFDM/54Mbps) status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode OPEN privacy OFF txpowmax 36 protmode CTS bintval 100 使用 WPA 的(无线)访问接入点 这一段将注重介绍在 &os; (无线)访问接入点上配置使用 WPA 安全协议。 更多有关 WPA 和配置基于 WPA 无线客户端的细节 请参阅 hostapd 守护进程将被用于处理与客户端的认证和在启用 WPA (无线)访问接入点上的密钥管理。 接下来,所有的配置操作都将在作为 AP 的 &os; 机器上完成。 一旦 AP 能够正确的工作了,便把如下这行加入 /etc/rc.conf 使得 hostapd 能在机器启动的时候自动运行: hostapd_enable="YES" 在配置 hostapd 以前, 请确保你已经完成了基本配置中所介绍的步骤 WPA-PSK WPA-PSK 旨在为没有认证服务器的小型网络而设计的。 配置文件为 /etc/hostapd.conf file: interface=ath0 debug=1 ctrl_interface=/var/run/hostapd ctrl_interface_group=wheel ssid=freebsdap wpa=1 wpa_passphrase=freebsdmall wpa_key_mgmt=WPA-PSK wpa_pairwise=CCMP TKIP 这一项标明了访问接入点所使用的无线接口。 这一项设置了执行 hostapd 时候显示相关信息的详细程度。 1 表示最小的级别。 ctrl_interface 这项给出了 hostapd 存储与其他外部程序(比如 &man.hostapd.cli.8;) 通信的域套接口文件路径。这里使用了默认值。 ctrl_interface_group 这行设置了允许访问控制界面文件的组属性 (这里我们使用了 wheel 组)。 这一项是设置网络的名称。 wpa 这项表示启用了 WPA 而且指明要使用何种 WPA 认证协议。 值 1 表示 AP 将使用 WPA-PSK。 wpa_passphrase 这项包含用于 WPA 认证的 ASCII 密码。 通常使用从丰富的字母表生成足够长度的强壮密码, 以不至于被轻易的猜测或攻击到。 wpa_key_mgmt 这行表明了我们所使用的密钥管理协议。 在这个例子中是 WPA-PSK。 wpa_pairwise 这项表示(无线)访问接入点所接受的加密算法。 在这个例子中,TKIP(WPA) 和 CCMP(WPA2) 密码都会被接受。 CCMP 密码是除 TKIP 外的另一种选择, CCMP 一般作为首选密码; 仅有在 CCMP 不能被使用的环境中选择 TKIP。 接下来的一步就是运行 hostapd &prompt.root /etc/rc.d/hostapd forcestart &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 2290 inet 192.168.0.1 netmask 0xffffff00 broadcast 192.168.0.255 inet6 fe80::211:95ff:fec3:dac%ath0 prefixlen 64 scopeid 0x4 ether 00:11:95:c3:0d:ac media: IEEE 802.11 Wireless Ethernet autoselect mode 11g <hostap> status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode WPA2/802.11i privacy MIXED deftxkey 2 TKIP 2:128-bit txpowmax 36 protmode CTS dtimperiod 1 bintval 100 现在客户端能够连接上运行的(无线)访问接入点了, 更多细节可以参阅 。 查看有哪些客户连接上了 AP 可以运行命令 ifconfig ath0 list sta 使用 WEP 的(无线)访问接入点 我们不推荐使用 WEP 来设置一个(无线)访问接入点, 因为没有认证的机制并容易被破解。 一些历史遗留下的无线网卡仅支持 WEP 作为安全协议, 这些网卡仅允许搭建不含认证或 WEP 协议的 AP。 在设置了正确的 SSID 和 IP 地址后,无线设备就可以进入 hostap 模式了: &prompt.root; ifconfig ath0 ssid freebsdap wepmode on weptxkey 3 wepkey 3:0x3456789012 mode 11g mediaopt hostap \ inet 192.168.0.1 netmask 255.255.255.0 weptxkey 表示传输中使用哪一个 WEP 密钥。 这个例子中用了第3把密钥(请注意密钥的编号从 1开始)。 这个参数必须设置以用来加密数据。 wepkey 表示设置所使用的 WEP 密钥。 它应该符合 index:key 这样的格式。 如果没有指定 index,那么默认值为 1。 这就是说如果我们使用了除第一把以外的密钥, 那么就需要指定 index。 再使用一次 ifconfig 命令查看 ath0 接口的状态: &prompt.root; ifconfig ath0 ath0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet 192.168.0.1 netmask 0xffffff00 broadcast 192.168.0.255 inet6 fe80::211:95ff:fec3:dac%ath0 prefixlen 64 scopeid 0x4 ether 00:11:95:c3:0d:ac media: IEEE 802.11 Wireless Ethernet autoselect mode 11g <hostap> status: associated ssid freebsdap channel 1 bssid 00:11:95:c3:0d:ac authmode OPEN privacy ON deftxkey 3 wepkey 3:40-bit txpowmax 36 protmode CTS dtimperiod 1 bintval 100 现在可以从另外一台无线机器上初始化一次扫描来找到这个 AP 了: &prompt.root; ifconfig ath0 up scan SSID BSSID CHAN RATE S:N INT CAPS freebsdap 00:11:95:c3:0d:ac 1 54M 22:1 100 EPS 现在客户机能够使用正确的参数(密钥等) 找到并连上(无线)访问接入点了, 更多细节请参阅 故障排除 如果您在使用无线网络时遇到了麻烦, 此处提供了一系列用以帮助排除故障的步骤。 如果您在列表中找不到无线访问点, 请确认您没有将无线设备配置为使用有限的一组频段。 如果您无法关联到无线访问点, 请确认您的通讯站配置与无线访问点的配置一致。 这包括认证模式以及安全协议。 尽可能简化您的配置。 如果您正使用类似 WPA 或 WEP 这样的安全协议, 请将无线访问点配置为开放验证和不采用安全措施, 并检查是否数据能够通过。 一旦您能够关联到无线访问点之后, 就可以使用简单的工具如 &man.ping.8; 来诊断安全配置了。 wpa_supplicant 提供了许多调试支持; 尝试手工运行它, 在启动时指定 选项, 并察看输出结果。 除此之外还有许多其它的底层调试工具。 您可以使用 /usr/src/tools/tools/net80211 中的 wlandebug 命令来启用 802.11 协议支持层的调试功能。 例如: &prompt.root; wlandebug -i ath0 +scan+auth+debug+assoc net.wlan.0.debug: 0 => 0xc80000<assoc,auth,scan> 可以用来启用与扫描无线访问点和 802.11 协议在安排通讯时与握手有关的控制台信息。 还有许多有用的统计信息是由 802.11 层维护的; wlanstats 工具可以显示这些信息。 这些统计数据能够指出由 802.11 层识别出来的错误。 请注意某些错误可能是由设备驱动在 802.11 层之下识别出来的, 因此这些错误可能并不显示。 要诊断与设备有关的问题, 您需要参考设备驱动程序的文档。 如果上述信息没能帮助您找到具体的问题所在, 请提交问题报告, 并在其中附上这些工具的输出。 Pav Lucistnik 作者:
pav@FreeBSD.org
雪平 中文翻译:
zxpmyth@yahoo.com.cn
苏义
蓝牙 蓝牙 简介 Bluetooth (蓝牙) 是一项无线技术, 用于建立带宽为 2.4GHZ,波长为 10 米的私有网络。 网络一般是由便携式设备,比加手机 (cellular phone), 掌上电脑 (handhelds) 和膝上电脑 (laptops)) 以 ad-hoc 形式组成。不象其它流行的无线技术——Wi-Fi,Bluetooth 提供了更高级的服务层面,像类 FTP 的文件服务、文件推送 (file pushing)、语音传送、串行线模拟等等。 在 &os; 里,蓝牙栈 (Bluetooth stack) 通过使用 Netgraph 框架 (请看 &man.netgraph.4;) 来的实现。 大量的"Bluetooth USB dongle"由 &man.ng.ubt.4; 驱动程序支持。 基于 Broadcom BCM2033 芯片组的 Bluetooth 设备可以通过 &man.ubtbcmfw.4; 和 &man.ng.ubt.4; 驱动程序支持。 3Com Bluetooth PC 卡 3CRWB60-A 由 &man.ng.bt3c.4; 驱动程序支持。 基于 Serial 和 UART 的蓝牙设备由 &man.sio.4;、&man.ng.h4.4; 和 &man.hcseriald.8;。本节介绍 USB Bluetooth dongle 的使用。 插入设备 默认的 Bluetooth 设备驱动程序已存在于内核模块里。 接入设备前,您需要将驱动程序加载入内核: &prompt.root; kldload ng_ubt 如果系统启动时 Bluetooth 设备已经存在于系统里, 那么从 /boot/loader.conf 里加载这个模块: ng_ubt_load="YES" 插入USB dongle。控制台(console)(或syslog中)会出现类似如下的信息: ubt0: vendor 0x0a12 product 0x0001, rev 1.10/5.25, addr 2 ubt0: Interface 0 endpoints: interrupt=0x81, bulk-in=0x82, bulk-out=0x2 ubt0: Interface 1 (alt.config 5) endpoints: isoc-in=0x83, isoc-out=0x3, wMaxPacketSize=49, nframes=6, buffer size=294 脚本 /etc/rc.d/bluetooth 是用来启动和停止 Bluetooth stack (蓝牙栈)的。 最好在拔出设备前停止 stack(stack),当然也不是非做不可。 启动 stack (栈) 时,会得到如下的输出: &prompt.root; /etc/rc.d/bluetooth start ubt0 BD_ADDR: 00:02:72:00:d4:1a Features: 0xff 0xff 0xf 00 00 00 00 00 <3-Slot> <5-Slot> <Encryption> <Slot offset> <Timing accuracy> <Switch> <Hold mode> <Sniff mode> <Park mode> <RSSI> <Channel quality> <SCO link> <HV2 packets> <HV3 packets> <u-law log> <A-law log> <CVSD> <Paging scheme> <Power control> <Transparent SCO data> Max. ACL packet size: 192 bytes Number of ACL packets: 8 Max. SCO packet size: 64 bytes Number of SCO packets: 8 HCI 主控制器接口 (HCI) 主控制器接口 (HCI) 提供了通向基带控制器和连接管理器的命令接口及访问硬件状态字和控制寄存器的通道。 这个接口提供了访问蓝牙基带 (Bluetooth baseband) 功能的统一方式。 主机上的 HCI 层与蓝牙硬件上的 HCI 固件交换数据和命令。 主控制器的传输层 (如物理总线) 驱动程序提供两个 HCI 层交换信息的能力。 为每个蓝牙 (Bluetooth) 设备创建一个 hci 类型的 Netgraph 结点。 HCI 结点一般连接蓝牙设备的驱动结点 (下行流) 和 L2CAP 结点 (上行流)。 所有的HCI操作必须在 HCI 结点上进行而不是设备驱动结点。HCI 结点的默认名是 devicehci。更多细节请参考 &man.ng.hci.4; 的联机手册。 最常见的任务是发现在 RF proximity 中的蓝牙 (Bluetooth) 设备。这个就叫做 质询(inquiry)。质询及 HCI 相关的操作可以由 &man.hccontrol.8; 工具来完成。 以下的例子展示如何找出范围内的蓝牙设备。 在几秒钟内您应该得到一张设备列表。 注意远程主机只有被置于 discoverable(可发现) 模式才能答应质询。 &prompt.user; hccontrol -n ubt0hci inquiry Inquiry result, num_responses=1 Inquiry result #0 BD_ADDR: 00:80:37:29:19:a4 Page Scan Rep. Mode: 0x1 Page Scan Period Mode: 00 Page Scan Mode: 00 Class: 52:02:04 Clock offset: 0x78ef Inquiry complete. Status: No error [00] BD_ADDR 是蓝牙设备的特定地址, 类似于网卡的 MAC 地址。需要用此地址与某个设备进一步地通信。 可以为 BD_ADDR 分配由人可读的名字 (human readable name)。 文件 /etc/bluetooth/hosts 包含已知蓝牙主机的信息。 下面的例子展示如何获得分配给远程设备的可读名。 &prompt.user; hccontrol -n ubt0hci remote_name_request 00:80:37:29:19:a4 BD_ADDR: 00:80:37:29:19:a4 Name: Pav's T39 如果在远程蓝牙上运行质询,您会发现您的计算机是 your.host.name (ubt0)。 分配给本地设备的名字可随时改变。 蓝牙系统提供点对点连接 (只有两个蓝牙设备参与) 和点对多点连接。在点对多点连接中,连接由多个蓝牙设备共享。 以下的例子展示如何取得本地设备的活动基带 (baseband) 连接列表。 &prompt.user; hccontrol -n ubt0hci read_connection_list Remote BD_ADDR Handle Type Mode Role Encrypt Pending Queue State 00:80:37:29:19:a4 41 ACL 0 MAST NONE 0 0 OPEN connection handle(连接柄) 在需要终止基带连接时有用。注意:一般不需要手动完成。 栈 (stack) 会自动终止不活动的基带连接。 &prompt.root; hccontrol -n ubt0hci disconnect 41 Connection handle: 41 Reason: Connection terminated by local host [0x16] 参考 hccontrol help 获取完整的 HCI 命令列表。大部分 HCI 命令不需要超级用户权限。 L2CAP 逻辑连接控制和适配协议(L2CAP) 逻辑连接控制和适配协议 (L2CAP) 为上层协议提供面向连接和无连接的数据服务, 并提供多协议功能和分割重组操作。L2CAP 充许上层协议和应用软件传输和接收最大长度为 64K 的 L2CAP 数据包。 L2CAP 基于 通道(channel) 的概念。 通道 (Channel) 是位于基带 (baseband) 连接之上的逻辑连接。 每个通道以多对一的方式绑定一个单一协议 (single protocol)。 多个通道可以绑定同一个协议,但一个通道不可以绑定多个协议。 每个在通道里接收到的 L2CAP 数据包被传到相应的上层协议。 多个通道可共享同一个基带连接。 为每个蓝牙 (Bluetooth) 设备创建一个 l2cap 类型的 Netgraph 结点。 L2CAP 结点一般连接 HCI 结点(下行流)和蓝牙设备的驱动结点(上行流)。 L2CAP 结点的默认名是 devicel2cap。 更多细节请参考 &man.ng.l2cap.4; 的联机手册。 一个有用的命令是 &man.l2ping.8;, 它可以用来 ping 其它设备。 一些蓝牙实现可能不会返回所有发送给它们的数据, 所以下例中的 0 bytes 是正常的。 &prompt.root; l2ping -a 00:80:37:29:19:a4 0 bytes from 0:80:37:29:19:a4 seq_no=0 time=48.633 ms result=0 0 bytes from 0:80:37:29:19:a4 seq_no=1 time=37.551 ms result=0 0 bytes from 0:80:37:29:19:a4 seq_no=2 time=28.324 ms result=0 0 bytes from 0:80:37:29:19:a4 seq_no=3 time=46.150 ms result=0 &man.l2control.8; 工具用于在 L2CAP 上进行多种操作。 以下这个例子展示如何取得本地设备的逻辑连接 (通道) 和基带连接的列表: &prompt.user; l2control -a 00:02:72:00:d4:1a read_channel_list L2CAP channels: Remote BD_ADDR SCID/ DCID PSM IMTU/ OMTU State 00:07:e0:00:0b:ca 66/ 64 3 132/ 672 OPEN &prompt.user; l2control -a 00:02:72:00:d4:1a read_connection_list L2CAP connections: Remote BD_ADDR Handle Flags Pending State 00:07:e0:00:0b:ca 41 O 0 OPEN 另一个诊断工具是 &man.btsockstat.1;。 它完成与 &man.netstat.1; 类似的操作, 只是用了蓝牙网络相关的数据结构。 以下这个例子显示与 &man.l2control.8; 相同的逻辑连接。 &prompt.user; btsockstat Active L2CAP sockets PCB Recv-Q Send-Q Local address/PSM Foreign address CID State c2afe900 0 0 00:02:72:00:d4:1a/3 00:07:e0:00:0b:ca 66 OPEN Active RFCOMM sessions L2PCB PCB Flag MTU Out-Q DLCs State c2afe900 c2b53380 1 127 0 Yes OPEN Active RFCOMM sockets PCB Recv-Q Send-Q Local address Foreign address Chan DLCI State c2e8bc80 0 250 00:02:72:00:d4:1a 00:07:e0:00:0b:ca 3 6 OPEN RFCOMM RFCOMM 协议 RFCOMM 协议提供基于 L2CAP 协议的串行端口模拟。 该协议基于 ETSI TS 07.10 标准。RFCOMM 是一个简单的传输协议, 附加了摸拟 9 针 RS-232(EIATIA-232-E) 串行端口的定义。 RFCOMM 协议最多支持 60 个并发连接 (RFCOMM通道)。 为了实现 RFCOMM, 运行于不同设备上的应用程序建立起一条关于它们之间通信段的通信路径。 RFCOMM实际上适用于使用串行端口的应用软件。 通信段是一个设备到另一个设备的蓝牙连接 (直接连接)。 RFCOMM 关心的只是直接连接设备之间的连接, 或在网络里一个设备与 modem 之间的连接。RFCOMM 能支持其它的配置, 比如在一端通过蓝牙无线技术通讯而在另一端使用有线接口。 在&os;,RFCOMM 协议在蓝牙套接字层 (Bluetooth sockets layer) 实现。 结对 设备的结对(Pairing of Devices) 默认情况下,蓝牙通信是不需要验证的, 任何设备可与其它任何设备对话。一个蓝牙设备 (比如手机) 可以选择通过验证以提供某种特殊服务 (比如拨号服务)。 蓝牙验证一般使用 PIN码(PIN codes)。 一个 PIN 码是最长为 16 个字符的 ASCII 字符串。 用户需要在两个设备中输入相同的PIN码。用户输入了 PIN 码后, 两个设备会生成一个 连接密匙(link key)。 接着连接密钥可以存储在设备或存储器中。 连接时两个设备会使用先前生成的连接密钥。 以上介绍的过程被称为 结对(pairing)。 注意如果任何一方丢失了连接密钥,必须重新进行结对。 守护进程 &man.hcsecd.8; 负责处理所有蓝牙验证请求。 默认的配置文件是 /etc/bluetooth/hcsecd.conf。 下面的例子显示一个手机的 PIN 码被预设为1234 device { bdaddr 00:80:37:29:19:a4; name "Pav's T39"; key nokey; pin "1234"; } PIN 码没有限制(除了长度)。有些设备 (例如蓝牙耳机) 会有一个预置的 PIN 码。 开关强制 &man.hcsecd.8; 守护进程处于前台,因此很容易看清发生了什么。 设置远端设备准备接收结对 (pairing),然后启动蓝牙连接到远端设备。 远端设备应该回应接收了结对并请求PIN码。输入与 hcsecd.conf 中一样的 PIN 码。 现在您的个人计算机已经与远程设备结对了。 另外您也可以在远程设备上初始结点。 在 &os; 5.5、 6.1 以及更新版本上, 可以通过在 /etc/rc.conf 文件中增加下面的行, 以便让 hcsecd 在系统启动时自动运行: hcsecd_enable="YES" 以下是简单的 hcsecd 服务输出样本: hcsecd[16484]: Got Link_Key_Request event from 'ubt0hci', remote bdaddr 0:80:37:29:19:a4 hcsecd[16484]: Found matching entry, remote bdaddr 0:80:37:29:19:a4, name 'Pav's T39', link key doesn't exist hcsecd[16484]: Sending Link_Key_Negative_Reply to 'ubt0hci' for remote bdaddr 0:80:37:29:19:a4 hcsecd[16484]: Got PIN_Code_Request event from 'ubt0hci', remote bdaddr 0:80:37:29:19:a4 hcsecd[16484]: Found matching entry, remote bdaddr 0:80:37:29:19:a4, name 'Pav's T39', PIN code exists hcsecd[16484]: Sending PIN_Code_Reply to 'ubt0hci' for remote bdaddr 0:80:37:29:19:a4 SDP 服务发现协议 (SDP) 服务发现协议 (SDP) 提供给客户端软件一种方法, 它能发现由服务器软件提供的服务及属性。 服务的属性包括所提供服务的类型或类别, 使用该服务所需要的机制或协议。 SDP 包括 SDP 服务器和 SDP 客户端之间的通信。 服务器维护一张服务记录列表,它介绍服务器上服务的特性。 每个服务记录包含关于单个服务的信息。通过发出 SDP 请求, 客户端会得到服务记录列表的信息。如果客户端 (或者客户端上的应用软件) 决定使用一个服务,为了使用这个服务它必须与服务提供都建立一个独立的连接。 SDP 提供了发现服务及其属性的机制,但它并不提供使用这些服务的机制。 一般地,SDP客户端按照服务的某种期望特征来搜索服务。 但是,即使没有任何关于由 SDP 服务端提供的服务的预设信息, 有时也能令人满意地发现它的服务记录里所描述的是哪种服务类型。 这种发现所提供服务的过程称为 浏览(browsing) 蓝牙 SDP 服务端 &man.sdpd.8; 和命令行客户端 &man.sdpcontrol.8; 都包括在了标准的 &os; 安装里。 下面的例子展示如何进行 SDP 浏览查询。 &prompt.user; sdpcontrol -a 00:01:03:fc:6e:ec browse Record Handle: 00000000 Service Class ID List: Service Discovery Server (0x1000) Protocol Descriptor List: L2CAP (0x0100) Protocol specific parameter #1: u/int/uuid16 1 Protocol specific parameter #2: u/int/uuid16 1 Record Handle: 0x00000001 Service Class ID List: Browse Group Descriptor (0x1001) Record Handle: 0x00000002 Service Class ID List: LAN Access Using PPP (0x1102) Protocol Descriptor List: L2CAP (0x0100) RFCOMM (0x0003) Protocol specific parameter #1: u/int8/bool 1 Bluetooth Profile Descriptor List: LAN Access Using PPP (0x1102) ver. 1.0 ...等等。注意每个服务有一个属性 (比如 RFCOMM 通道)列表。 根据服务您可能需要为一些属性做个注释。 有些蓝牙实现 (Bluetooth implementation)不支持服务浏览, 可能会返回一个空列表。这种情况,可以搜索指定的服务。 下面的例子展示如何搜索 OBEX Object Push (OPUSH) 服务: &prompt.user; sdpcontrol -a 00:01:03:fc:6e:ec search OPUSH 要在 &os; 里为蓝牙客户端提供服务,可以使用 &man.sdpd.8; 服务。 在 &os; 5.5、 6.1 和更新版本之上, 可以通过在 /etc/rc.conf 中加入下面的行: sdpd_enable="YES" 接下来使用下面的命令来启动 sdpd 服务: &prompt.root; /etc/rc.d/sdpd start 需要为远端提供蓝牙服务的本地的服务程序会使用本地 SDP 进程注册服务。像这样的程序就有 &man.rfcomm.pppd.8;。 一旦启动它,就会使用本地 SDP 进程注册蓝牙 LAN 服务。 使用本地 SDP 进程注册的服务列表,可以通过本地控制通道发出 SDP 浏览查询获得: &prompt.root; sdpcontrol -l browse 拨号网络 (DUN) 和使用 PPP(LAN) 层面的网络接入 拨号网络 (DUN) 配置通常与 modem 和手机一起使用。 如下是这一配置所涉及的内容: 计算机使用手机或 modem 作为无线 modem 来连接拨号因特网连入服务器, 或者使用其它的拨号服务; 计算机使用手机或 modem 接收数据请求。 使用 PPP(LAN) 层面的网络接入常使用在如下情形: 单个蓝牙设备的局域网连入; 多个蓝牙设备的局域网接入; PC 到 PC (使用基于串行线模拟的 PPP 网络)。 在 &os; 中,两个层面使用 &man.ppp.8; 和 &man.rfcomm.pppd.8; (一种封装器,可以将 RFCOMM 蓝牙连接转换为 PPP 可操作的东西) 来实现。 在使用任何层面之前,一个新的 PPP 标识必须在 /etc/ppp/ppp.conf 中建立。 想要实例请参考 &man.rfcomm.pppd.8;。 在下面的例子中,&man.rfcomm.pppd.8; 用来在 NUN RFCOMM 通道上打开一个到 BD_ADDR 为 00:80:37:29:19:a4 的设备的 RFCOMM 连接。具体的 RFCOMM 通道号要通过 SDP 从远端设备获得。也可以手动指定通 RFCOMM,这种情况下 &man.rfcomm.pppd.8; 将不能执行 SDP 查询。使用 &man.sdpcontrol.8; 来查找远端设备上的 RFCOMM 通道。 &prompt.root; rfcomm_pppd -a 00:80:37:29:19:a4 -c -C dun -l rfcomm-dialup 为了提供 PPP(LAN) 网络接入服务,必须运行 &man.sdpd.8; 服务。一个新的 LAN 客户端条目必须在 /etc/ppp/ppp.conf 文件中建立。 想要实例请参考 &man.rfcomm.pppd.8;。 最后,在有效地通道号上开始 RFCOMM PPP 服务。 RFCOMM PPP 服务会使用本地 SDP 进程自动注册蓝牙 LAN 服务。下面的例子展示如何启动 RFCOMM PPP 服务。 &prompt.root; rfcomm_pppd -s -C 7 -l rfcomm-server OBEX OBEX 对象推送 (OBEX Object Push - OPUSH) 层面 OBEX协议被广泛地用于移动设备之间简单的文件传输。 它的主要用处是在红外线通信领域, 被用于笔记本或手持设备之间的一般文件传输。 OBEX 服务器和客户端由第三方软件包 obexapp实现,它可以从 comms/obexapp port 安装。 OBEX 客户端用于向 OBEX 服务器推入或接出对象。 一个对像可以是(举个例子)商业卡片或约会。 OBEX 客户能通过 SDP 从远程设备取得 RFCOMM 通道号。这可以通过指定服务名代替 RFCOMM 通道号来完成。支持的服务名是有:IrMC、FTRN 和 OPUSH。 也可以用数字来指定 RFCOMM 通道号。下面是一个 OBEX 会话的例子,一个设备信息对像从手机中被拉出, 一个新的对像被推入手机的目录。 &prompt.user; obexapp -a 00:80:37:29:19:a4 -C IrMC obex> get telecom/devinfo.txt devinfo-t39.txt Success, response: OK, Success (0x20) obex> put new.vcf Success, response: OK, Success (0x20) obex> di Success, response: OK, Success (0x20) 为了提供 OBEX 推入服务,&man.sdpd.8; 必须处于运行状态。必须创建一个根目录用于存放所有进入的对象。 根文件夹的默认路径是 /var/spool/obex。 最后,在有效的 RFCOMM 通道号上开始 OBEX 服务。OBEX 服务会使用 SDP 进程自动注册 OBEX 对象推送 (OBEX Object Push) 服务。 下面的例子展示如何启动 OBEX 服务。 &prompt.root; obexapp -s -C 10 串口(SP)层面 串口(SP)层面允许蓝牙设备完成 RS232 (或类似) 串口线的仿真。 这个层面所涉及到情形是, 通过虚拟串口使用蓝牙代替线缆来处理以前的程序。 工具 &man.rfcomm.sppd.1; 来实现串口层。 Pseudo tty 用来作为虚拟的串口。 下面的例子展示如何连接远程设备的串口服务。 注意您不必指定 RFCOMM 通道——&man.rfcomm.sppd.1; 能够通过 SDP 从远端设备那里获得。 如果您想代替它的话,可以在命令行里指定 RFCOMM 通道来实现: &prompt.root; rfcomm_sppd -a 00:07:E0:00:0B:CA -t /dev/ttyp6 rfcomm_sppd[94692]: Starting on /dev/ttyp6... 一旦连接上,pseudo tty就可以充当串口了: &prompt.root; cu -l ttyp6 问题解答 不能连接远端设备 一些较老的蓝牙设备并不支持角色转换 (role switching)。默认情况下,&os; 接受一个新的连接时, 它会尝试进行角色转换并成为主控端 (master)。 不支持角色转换的设备将无法连接。 注意角色转换是在新连接建立时运行的, 因此如果远程设备不支持角色转换,就不可能向它发出请求。 一个 HCI 选项用来在本地端禁用角色转换。 &prompt.root; hccontrol -n ubt0hci write_node_role_switch 0 如果有错, 能否知道到底正在发生什么? 可以。 需要借助第三方软件包 hcidump, 它可以通过 comms/hcidump port 来安装。 hcidump 工具和 &man.tcpdump.1; 非常相像。 它可以用来显示蓝牙数据包的内容, 并将其记录到文件中。
Andrew Thompson 原作 桥接 简介 IP 子网 桥接 有时, 会有需要将一个物理网络分成两个独立的网段, 而不是创建新的 IP 子网, 并将其通过路由器相连。 以这种方式连接两个网络的设备称为 网桥 (bridge)。 有两个网络接口的 FreeBSD 系统可以作为网桥来使用。 网桥通过学习每个网络接口上的 MAC 层地址 (以太网地址) 工作。 只当数据包的源地址和目标地址处于不同的网络时, 网桥才进行转发。 在很多方面,网桥就像一个带有很少端口的以太网交换机。 适合桥接的情况 适合使用网桥的, 有许多种不同的情况。 使多个网络相互联通 网桥的基本操作是将两个或多个网段连接在一起。 由于各式各样的原因, 人们会希望使用一台真正的计算机, 而不是网络设备来充任网桥的角色, 常见的原因包括线缆的限制、 需要进行防火墙, 或为虚拟机网络接口连接虚拟网络。 网桥也可以将无线网卡以 hostap 模式接入有线网络。 过滤/数据整形防火墙 防火墙 NAT 使用防火墙的常见情形是无需进行路由或网络地址转换的情况 (NAT)。 举例来说, 一家通过 DSL 或 ISDN 连接到 ISP 的小公司, 拥有 13 个 ISP 分配的全局 IP 地址和 10 台 PC。 在这种情况下, 由于划分子网的问题, 采用路由来实现防火墙会比较困难。 路由器 DSL ISDN 基于网桥的防火墙可以串接在 DSL/ISDN 路由器的后面, 而无需考虑 IP 编制的问题。 网络监视 网桥可以用于连接两个不同的网段, 并用于监视往返的以太网帧。 这可以通过在网桥接口上使用 &man.bpf.4;/&man.tcpdump.1;, 或通过将全部以太网帧复制到另一个网络接口 (span 口) 来实现。 2层 VPN 通过 IP 连接的网桥, 可以利用 EtherIP 隧道或基于 &man.tap.4; 的解决方案, 如 OpenVPN 可以将两个以太网连接到一起。 2层 冗余 网络可以通过多条链路连接在一起, 并使用生成树协议 (Spanning Tree Protocol) 来阻止多余的通路。 为使以太网能够正确工作, 两个设备之间应该只有一条激活通路, 而生成树能够检测环路, 并将多余的链路置为阻断状态。 当激活通路断开时, 协议能够计算另外一棵树, 并重新激活阻断的通路, 以恢复到网络各点的连通性。 内核配置 这一节主要介绍 &man.if.bridge.4; 网桥实现。 除此之外, 还有一个基于 netgraph 的网桥实现, 如欲了解进一步细节, 请参见联机手册 &man.ng.bridge.4;。 网桥驱动是一个内核模块, 并会随使用 &man.ifconfig.8; 创建网桥接口时自动加载。 您也可以将 device if_bridge 加入到内核配置文件中, 以便将其静态联编进内核。 包过滤可以通过使用了 &man.pfil.9; 框架的任意一种防火墙软件包来完成。 这些防火墙可以以模块形式加载, 也可以静态联编进内核。 通过配合 &man.altq.4; 和 &man.dummynet.4;, 网桥也可以用于流量控制。 启用网桥 网桥是通过接口复制来创建的。 您可以使用 &man.ifconfig.8; 来创建网桥接口, 如果内核不包括网桥驱动, 则它会自动将其载入。 &prompt.root; ifconfig bridge create bridge0 &prompt.root; ifconfig bridge0 bridge0: flags=8802<BROADCAST,SIMPLEX,MULTICAST> metric 0 mtu 1500 ether 96:3d:4b:f1:79:7a id 00:00:00:00:00:00 priority 32768 hellotime 2 fwddelay 15 maxage 20 holdcnt 6 proto rstp maxaddr 100 timeout 1200 root id 00:00:00:00:00:00 priority 0 ifcost 0 port 0 如此就建立了一个网桥接口, 并为其随机分配了以太网地址。 maxaddrtimeout 参数能够控制网桥在转发表中保存多少个 MAC 地址, 以及表项中主机的过期时间。 其他参数控制生成树的运转方式。 将成员网络接口加入网桥。 为了让网桥能够为所有网桥成员接口转发包, 网桥接口和所有成员接口都需要处于启用状态: &prompt.root; ifconfig bridge0 addm fxp0 addm fxp1 up &prompt.root; ifconfig fxp0 up &prompt.root; ifconfig fxp1 up 网桥现在会在 fxp0fxp1 之间转发以太网帧。 等效的 /etc/rc.conf 配置如下, 如此配置将在系统启动时创建同样的网桥。 cloned_interfaces="bridge0" ifconfig_bridge0="addm fxp0 addm fxp1 up" ifconfig_fxp0="up" ifconfig_fxp1="up" 如果网桥主机需要 IP 地址, 则应将其绑在网桥设备本身, 而不是某个成员设备上。 这可以通过静态设置或 DHCP 来完成: &prompt.root; ifconfig bridge0 inet 192.168.0.1/24 除此之外, 也可以为网桥接口指定 IPv6 地址。 防火墙 firewall (防火墙) 当启用包过滤时, 通过网桥的包可以分别在进入的网络接口、 网桥接口和发出的网络接口上进行过滤。 这些阶段均可禁用。 当包的流向很重要时, 最好在成员接口而非网桥接口上配置防火墙。 网桥上可以进行许多配置以决定非 IP 及 ARP 包能否通过, 以及通过 IPFW 实现二层防火墙。 请参见 &man.if.bridge.4; 联机手册以了解进一步的细节。 生成树 网桥驱动实现了快速生成树协议 (RSTP 或 802.1w), 并与较早的生成树协议 (STP) 兼容。 生成树可以用来在网络拓扑中检测并消除环路。 RSTP 提供了比传统 STP 更快的生成树覆盖速度, 这种协议会在相邻的交换机之间交换信息, 以迅速进入转发状态, 而不会产生环路。 下表展示了支持的运行模式: OS 版本 STP 模式 默认模式 &os; 5.4—&os; 6.2 STP STP &os; 6.3+ RSTP 或 STP STP &os; 7.0+ RSTP 或 STP RSTP 使用 stp 命令可以在成员接口上启用生成树。 对包含 fxp0fxp1 的网桥, 可以用下列命令启用 STP: &prompt.root; ifconfig bridge0 stp fxp0 stp fxp1 bridge0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 ether d6:cf:d5:a0:94:6d id 00:01:02:4b:d4:50 priority 32768 hellotime 2 fwddelay 15 maxage 20 holdcnt 6 proto rstp maxaddr 100 timeout 1200 root id 00:01:02:4b:d4:50 priority 32768 ifcost 0 port 0 member: fxp0 flags=1c7<LEARNING,DISCOVER,STP,AUTOEDGE,PTP,AUTOPTP> port 3 priority 128 path cost 200000 proto rstp role designated state forwarding member: fxp1 flags=1c7<LEARNING,DISCOVER,STP,AUTOEDGE,PTP,AUTOPTP> port 4 priority 128 path cost 200000 proto rstp role designated state forwarding 网桥的生成树 ID 为 00:01:02:4b:d4:50 而优先级为 32768。 其中 root id 与生成树相同, 表示这是作为生成树根的网桥。 另一个网桥也启用了生成树: bridge0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 ether 96:3d:4b:f1:79:7a id 00:13:d4:9a:06:7a priority 32768 hellotime 2 fwddelay 15 maxage 20 holdcnt 6 proto rstp maxaddr 100 timeout 1200 root id 00:01:02:4b:d4:50 priority 32768 ifcost 400000 port 4 member: fxp0 flags=1c7<LEARNING,DISCOVER,STP,AUTOEDGE,PTP,AUTOPTP> port 4 priority 128 path cost 200000 proto rstp role root state forwarding member: fxp1 flags=1c7<LEARNING,DISCOVER,STP,AUTOEDGE,PTP,AUTOPTP> port 5 priority 128 path cost 200000 proto rstp role designated state forwarding 这里的 root id 00:01:02:4b:d4:50 priority 32768 ifcost 400000 port 4 表示根网桥是前面的 00:01:02:4b:d4:50, 而从此网桥出发的通路代价为 400000, 此通路到根网桥是通过 port 4fxp0 连接的。 网桥的高级用法 重建流量流 网桥支持监视模式, 在 &man.bpf.4; 处理之后会将包丢弃, 而不是继续处理或转发。 这可以用于将两个或多个接口上的输入转化为一个 &man.bpf.4; 流。 在将两个独立的接口上的传输的 RX/TX 信号重整为一个时, 这会非常有用。 如果希望将四个网络接口上的输入转成一个流: &prompt.root; ifconfig bridge0 addm fxp0 addm fxp1 addm fxp2 addm fxp3 monitor up &prompt.root; tcpdump -i bridge0 镜像口 (Span port) 网桥收到的每个以太网帧都可以发到镜像口上。 网桥上的镜像口数量没有限制, 如果一个接口已经被配置为镜像口, 则它就不能再作为网桥的成员口来使用。 这种用法主要是为与网桥镜像口相连的监听机配合使用。 如果希望将所有帧发到名为 fxp4 的接口上: &prompt.root; ifconfig bridge0 span fxp4 专用接口 (Private interface) 专用接口不会转发流量到除专用接口之外的其他端口。 这些流量会无条件地阻断, 因此包括 ARP 在内的以太网帧均不会被转发。 如果需要选择性地阻断流量, 则应使用防火墙。 自学习接口 (Sticky Interfaces) 如果网桥的成员接口标记为自学习, 则动态学习的地址项一旦进入转发快取缓存, 即被认为是静态项。 自学习项不会从快取缓存中过期或替换掉, 即使地址在另一接口上出现也是如此。 这使得不必事先发布转发表, 也能根据学习结果得到静态项的有点, 但在这些网段被网桥看到的客户机, 就不能漫游至另一网段了。 另一种用法是将网桥与 VLAN 功能连用, 这样客户网络会被隔离在一边, 而不会浪费 IP 地址空间。 考虑 CustomerAvlan100 上, 而 CustomerB 则在 vlan101 上。 网桥地址为 192.168.0.1, 同时作为 internet 路由器使用。 &prompt.root; ifconfig bridge0 addm vlan100 sticky vlan100 addm vlan101 sticky vlan101 &prompt.root; ifconfig bridge0 inet 192.168.0.1/24 两台客户机均将 192.168.0.1 作为默认网关, 由于网桥快取缓存是自学习的, 因而它们无法伪造 MAC 地址来截取其他客户机的网络流量。 在 VLAN 之间的通讯可以通过专用接口 (或防火墙) 来阻断: &prompt.root; ifconfig bridge0 private vlan100 private vlan101 这样这些客户机就完全相互隔离了。 可以使用整个的 /24 地址空间, 而无需划分子网。 地址限制 接口后的源 MAC 地址数量是可以控制的。 一旦到达了限制未知源地址的包将会被丢弃, 直至现有缓存中的一项过期或被移除。 下面的例子是设置 CustomerAvlan100 上可连接的以太网设备最大值为 10。 &prompt.root; ifconfig bridge0 ifmaxaddr vlan100 10 SNMP 管理 网桥接口和 STP 参数能够由 &os; 基本系统的 SNMP 守护进程进行管理。导出的网桥 MIB 符和 IETF 标准, 所以任何 SNMP 客户端或管理包都可以被用来接收数据。 在网桥机器上从/etc/snmp.config 文件中去掉以下这行的注释 begemotSnmpdModulePath."bridge" = "/usr/lib/snmp_bridge.so" 并启动 bsnmpd 守护进程。 其他的配置选项诸如 community names 和 access lists 可能也许也需要修改。 参阅 &man.bsnmpd.1; 和 &man.snmp.bridge.3; 获取更多信息。 以下的例子中使用了 Net-SNMP 软件 (net-mgmt/net-snmp) 来查询一个网桥,当然同样也能够使用port net-mgmt/bsnmptools。 在 SNMP 客户端 Net-SNMP 的配置文件 $HOME/.snmp/snmp.conf 中 加入以下几行来导入网桥的 MIB 定义: mibdirs +/usr/share/snmp/mibs mibs +BRIDGE-MIB:RSTP-MIB:BEGEMOT-MIB:BEGEMOT-BRIDGE-MIB 通过 IETF BRIDGE-MIB(RFC4188) 监测一个单独的网桥 &prompt.user; snmpwalk -v 2c -c public bridge1.example.com mib-2.dot1dBridge BRIDGE-MIB::dot1dBaseBridgeAddress.0 = STRING: 66:fb:9b:6e:5c:44 BRIDGE-MIB::dot1dBaseNumPorts.0 = INTEGER: 1 ports BRIDGE-MIB::dot1dStpTimeSinceTopologyChange.0 = Timeticks: (189959) 0:31:39.59 centi-seconds BRIDGE-MIB::dot1dStpTopChanges.0 = Counter32: 2 BRIDGE-MIB::dot1dStpDesignatedRoot.0 = Hex-STRING: 80 00 00 01 02 4B D4 50 ... BRIDGE-MIB::dot1dStpPortState.3 = INTEGER: forwarding(5) BRIDGE-MIB::dot1dStpPortEnable.3 = INTEGER: enabled(1) BRIDGE-MIB::dot1dStpPortPathCost.3 = INTEGER: 200000 BRIDGE-MIB::dot1dStpPortDesignatedRoot.3 = Hex-STRING: 80 00 00 01 02 4B D4 50 BRIDGE-MIB::dot1dStpPortDesignatedCost.3 = INTEGER: 0 BRIDGE-MIB::dot1dStpPortDesignatedBridge.3 = Hex-STRING: 80 00 00 01 02 4B D4 50 BRIDGE-MIB::dot1dStpPortDesignatedPort.3 = Hex-STRING: 03 80 BRIDGE-MIB::dot1dStpPortForwardTransitions.3 = Counter32: 1 RSTP-MIB::dot1dStpVersion.0 = INTEGER: rstp(2) dot1dStpTopChanges.0的值为2 意味着 STP 网桥拓扑改变了2次,拓扑的改变表示1个或多个 网络中的连接改变或失效并且有一个新树生成。 dot1dStpTimeSinceTopologyChange.0 的值则能够显示这是何时改变的。 监测多个网桥接口可以使用 private BEGEMOT-BRIDGE-MIB: &prompt.user; snmpwalk -v 2c -c public bridge1.example.com enterprises.fokus.begemot.begemotBridge BEGEMOT-BRIDGE-MIB::begemotBridgeBaseName."bridge0" = STRING: bridge0 BEGEMOT-BRIDGE-MIB::begemotBridgeBaseName."bridge2" = STRING: bridge2 BEGEMOT-BRIDGE-MIB::begemotBridgeBaseAddress."bridge0" = STRING: e:ce:3b:5a:9e:13 BEGEMOT-BRIDGE-MIB::begemotBridgeBaseAddress."bridge2" = STRING: 12:5e:4d:74:d:fc BEGEMOT-BRIDGE-MIB::begemotBridgeBaseNumPorts."bridge0" = INTEGER: 1 BEGEMOT-BRIDGE-MIB::begemotBridgeBaseNumPorts."bridge2" = INTEGER: 1 ... BEGEMOT-BRIDGE-MIB::begemotBridgeStpTimeSinceTopologyChange."bridge0" = Timeticks: (116927) 0:19:29.27 centi-seconds BEGEMOT-BRIDGE-MIB::begemotBridgeStpTimeSinceTopologyChange."bridge2" = Timeticks: (82773) 0:13:47.73 centi-seconds BEGEMOT-BRIDGE-MIB::begemotBridgeStpTopChanges."bridge0" = Counter32: 1 BEGEMOT-BRIDGE-MIB::begemotBridgeStpTopChanges."bridge2" = Counter32: 1 BEGEMOT-BRIDGE-MIB::begemotBridgeStpDesignatedRoot."bridge0" = Hex-STRING: 80 00 00 40 95 30 5E 31 BEGEMOT-BRIDGE-MIB::begemotBridgeStpDesignatedRoot."bridge2" = Hex-STRING: 80 00 00 50 8B B8 C6 A9 通过 mib-2.dot1dBridge 子树改变正在被监测的网桥接口: &prompt.user; snmpset -v 2c -c private bridge1.example.com BEGEMOT-BRIDGE-MIB::begemotBridgeDefaultBridgeIf.0 s bridge2 Andrew Thompson Written by 链路聚合与故障转移 lagg failover (故障转移) fec lacp loadbalance (负载均衡) roundrobin (轮转) 介绍 使用 &man.lagg.4; 接口, 能够将多个网络接口聚合为一个虚拟接口, 以提供容灾和高速连接的能力。 运行模式 failover (故障转移) 只通过主网口收发数据。 如果主网口不可用, 则使用下一个激活的网口。 您在这里加入的第一个网口便会被视为主网口; 此后加入的其他网口, 则会被视为故障转移的备用网口。 fec 用以支持 Cisco EtherChannel。 这是一种静态配置, 并不进行节点间协商或交换以太网帧来监控链路情况。 如果交换机支持 LACP, 则应使用后者而非这种配置。 这种做法是将输出流量在激活的网口之间以协议头散列信息为依据分拆, 并接收来自任意激活网口的入流量。 散列信息包含以太网源地址、 目的地址, 以及 (如果有的话) VLAN tag 和 IPv4/IPv6 源地址及目的地址信息。 lacp 支持 IEEE 802.3ad 链路聚合控制协议 (LACP) 和标记协议。 LACP 能够在节点与若干链路聚合组之间协商链路。 每一个链路聚合组 (LAG) 由一组相同速度、 以全双工模式运行的网口组成。 流量在 LAG 中的网口之间, 会以总速度最大的原则进行分摊。 当物理链路发生变化时, 链路聚合会迅速适应变动形成新的配置。 这种做法也是将输出流量在激活的网口之间以协议头散列信息为依据分拆, 并接收来自任意激活网口的入流量。 散列信息包含以太网源地址、 目的地址, 以及 (如果有的话) VLAN tag 和 IPv4/IPv6 源地址及目的地址信息。 loadbalance (负载均衡) 这是 fec 模式的别名。 roundrobin (轮转) 将输出流量以轮转方式在所有激活端口之间调度, 并从任意激活端口接收进入流量。 这种模式违反了以太网帧排序规则, 因此应小心使用。 例子 与 Cisco 交换机配合完成 LACP 链路聚合 在这个例子中, 我们将 &os; 的两个网口作为一个负载均衡和故障转移链路聚合组接到交换机上。 在此基础上, 还可以增加更多的网口, 以提高吞吐量和故障容灾能力。 由于以太网链路上两节点间的帧序是强制性的, 因此两个节点之间的连接速度, 会取决于一块网卡的最大速度。 传输算法会尽量采用更多的信息, 以便将不同的网络流量分摊到不同的网络接口上, 并平衡不同网口的负载。 在 Cisco 交换机上将网口添加到通道组 (channel group) 中。 interface FastEthernet0/1 channel-group 1 mode active channel-protocol lacp ! interface FastEthernet0/2 channel-group 1 mode active channel-protocol lacp ! 在 &os; 机器上创建 lagg 接口。 &prompt.root; ifconfig lagg0 create &prompt.root; ifconfig lagg0 up laggproto lacp laggport fxp0 laggport fxp1 从 ifconfig 查看接口状态: 标记为 ACTIVE 的接口属于激活的聚合组, 并且已经完成了与交换机的协商过程, 能够收发网络流量了。 您可以利用 &man.ifconfig.8; 的输出细节来检视 LAG 标识。 lagg0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=8<VLAN_MTU> ether 00:05:5d:71:8d:b8 media: Ethernet autoselect status: active laggproto lacp laggport: fxp1 flags=1c<ACTIVE,COLLECTING,DISTRIBUTING> laggport: fxp0 flags=1c<ACTIVE,COLLECTING,DISTRIBUTING> 交换机上会显示哪些端口是激活的。 如果需要了解更多细节, 则可以使用 show lacp neighbor detail switch# show lacp neighbor Flags: S - Device is requesting Slow LACPDUs F - Device is requesting Fast LACPDUs A - Device is in Active mode P - Device is in Passive mode Channel group 1 neighbors Partner's information: LACP port Oper Port Port Port Flags Priority Dev ID Age Key Number State Fa0/1 SA 32768 0005.5d71.8db8 29s 0x146 0x3 0x3D Fa0/2 SA 32768 0005.5d71.8db8 29s 0x146 0x4 0x3D 故障转移模式 故障转移模式可以用于在主端口连接中断时切换到备用端口。 &prompt.root; ifconfig lagg0 create &prompt.root; ifconfig lagg0 up laggproto failover laggport fxp0 laggport fxp1 lagg0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> metric 0 mtu 1500 options=8<VLAN_MTU> ether 00:05:5d:71:8d:b8 media: Ethernet autoselect status: active laggproto failover laggport: fxp1 flags=0<> laggport: fxp0 flags=5<MASTER,ACTIVE> 系统将在 fxp0 上进行流量的收发。 如果 fxp0 的连接中断, 则 fxp1 会自动成为激活连接。 如果主端口的连接恢复, 则它又会成为激活连接。 Jean-François Dockès 更新: Alex Dupre 重新组织及增强: 雪平 中文翻译:
zxpmyth@yahoo.com.cn
苏义
无盘操作 无盘工作站 无盘操作 FreeBSD 主机可以从网络启动而无需本地磁盘就可操作, 使用的是从 NFS 服务器装载的文件系统。 除了标准的配置文件,无需任何的系统修改。 很容易设置这样的系统因为所有必要的元素都很容易得到: 至少有两种可能的方法从网络加载内核: PXE:&intel; 的先启动执行环境 (Preboot eXecution Environment) 系统是一种灵活的引导 ROM 模式,这个 ROM 内建在一些网卡或主板的中。查看 &man.pxeboot.8; 以获取更多细节。 Etherboot port (net/etherboot) 产生通过网络加载内核的可 ROM 代码。这些代码可以烧入网卡上的 PROM 上,或从本地软盘 (或硬盘) 驱动器加载,或从运行着的 &ms-dos; 系统加载。它支持多种网卡。 一个样板脚本 (/usr/share/examples/diskless/clone_root) 简化了对服务器上的工作站根文件系统的创建和维护。 这个脚本需要少量的自定义,但您能很快的熟悉它。 /etc 存在标准的系统启动文件用于侦测和支持无盘的系统启动。 可以向 NFS 文件或本地磁盘进行交换(如果需要的话)。 设置无盘工作站有许多方法。 有很多相关的元素大部分可以自定义以适合本地情况。 以下将介绍一个完整系统的安装,强调的是简单性和与标准 FreeBSD 启动脚本的兼容。介绍的系统有以下特性: 无盘工作站使用一个共享的只读 / 文件系统和一个共享的只读/usr root 文件系统是一份标准的 FreeBSD 根文件系统 (一般是服务器的),只是一些配置文件被特定于无盘操作的配置文件覆盖。 root 文件系统必须可写的部分被 &man.md.4; 文件系统覆盖。 任何的改写在重启后都会丢失。 内核由 etherbootPXE 传送和加载, 有些情况可能会指定使用其中之一。 如上所述,这个系统是不安全的。 它应该处于网络的受保护区域并不被其它主机信任。 这部分所有的信息均在 5.2.1-RELEASE 上测试过。 背景信息 设置无盘工作站相对要简单而又易出错。 有时分析一些原因是很难的。例如: 编译时选项在运行时可能产生不同的行为。 出错信息经常是加密了的或根本就没有。 在这里, 涉及到的一些背景知识对于可能出现的问题的解决是很有帮助的。 要成功地引导系统还有些操作需要做。 机子需要获取初始的参数,如它的 IP 地址、执行文件、服务器名、根路径。这个可以使用 或 BOOTP 协议来完成。 DHCP 是 BOOTP 的兼容扩展, 并使用相同的端口和基本包格式。 只使用 BOOTP 来配置系统也是可行的。 &man.bootpd.8; 服务程序被包含在基本的 &os; 系统里。 不过,DHCP 相比 BOOTP 有几个好处 (更好的配置文件,使用 PXE 的可能性,以及许多其它并不直接相关的无盘操作), 接着我们会要描述一个 DHCP 配置, 可能的话会利用与使用 &man.bootpd.8; 相同的例子。这个样板配置会使用ISC DHCP 软件包 (3.0.1.r12 发行版安装在测试服务器上)。 机子需要传送一个或多个程序到本地内存。 TFTPNFS 会被使用。选择TFTP 还是 NFS 需要在几个地方的编译时间选项里设置。 通常的错误源是为文件名指定了错误的协议:TFTP 通常从服务器里的一个单一目录传送所有文件,并需要相对这个目录的文件名。 NFS 需要的是绝对文件路径。 介于启动程序和内核之间的可能的部分需要被初始化并执行。 在这部分有几个重要的变量: PXE 会装入 &man.pxeboot.8;——它是 &os; 第三阶段装载器的修改版。 &man.loader.8; 会获得许多参数用于系统启动, 并在传送控制之前把它们留在内核环境里。 在这种情况下,使用 GENERIC 内核就可能了。 Etherboot 会做很少的准备直接装载内核。 您要使用指定的选项建立 (build) 内核。 PXEEtherboot 工作得一样的好。 不过, 因为一般情况下内核希望 &man.loader.8; 做了更多的事情, PXE 是推荐的方法。 如果您的 BIOS 和网卡都支持 PXE, 就应该使用它。 最后,机子需要访问它的文件系统。 NFS 使用在所有的情况下。 查看 &man.diskless.8; 手册页。 安装说明 配置使用<application>ISC DHCP</application> DHCP 无盘操作 ISC DHCP 服务器可以回应 BOOTP 和 DHCP 的请求。 ISC DHCP 3.0 并不属于基本系统。首先您需要安装 - net/isc-dhcp3-server + net/isc-dhcp30-server port 或相应的 一旦安装了 ISC DHCP, 还需要一个配置文件才能运行 (通常名叫 /usr/local/etc/dhcpd.conf)。 这里有个注释过的例子,里边主机 margaux 使用 Etherboot, 而主机corbieres 使用 PXE default-lease-time 600; max-lease-time 7200; authoritative; option domain-name "example.com"; option domain-name-servers 192.168.4.1; option routers 192.168.4.1; subnet 192.168.4.0 netmask 255.255.255.0 { use-host-decl-names on; option subnet-mask 255.255.255.0; option broadcast-address 192.168.4.255; host margaux { hardware ethernet 01:23:45:67:89:ab; fixed-address margaux.example.com; next-server 192.168.4.4; filename "/data/misc/kernel.diskless"; option root-path "192.168.4.4:/data/misc/diskless"; } host corbieres { hardware ethernet 00:02:b3:27:62:df; fixed-address corbieres.example.com; next-server 192.168.4.4; filename "pxeboot"; option root-path "192.168.4.4:/data/misc/diskless"; } } 这个选项告诉 dhcpd 发送host 里声明的用于无盘主机的主机名的值。 另外可能会增加一个 option host-name margauxhost 声明里。 next-server 正式指定 TFTPNFS 服务用于载入装载器或内核文件 (默认使用的是相同的主机作为DHCP 服务器)。 filename 正式定义这样的文件——etherbootPXE 为执行下一步将装载它。 根据使用的传输方式,它必须要指定。 Etherboot 可以被编译来使用 NFSTFTP。 &os; port 默认配置了NFSPXE 使用 TFTP, 这就是为什么在这里使用相对文件名 (这可能依赖于 TFTP 服务器配置,不过会相当典型)。 同样,PXE 会装载 pxeboot, 而不是内核。另外有几个很有意思的可能,如从 &os; CD-ROM 的 /boot 目录装载 pxeboot (因为 &man.pxeboot.8; 能够装载 GENERIC 内核,这就使得可以使用 PXE 从远程的 CD-ROM 里启动)。 root-path 选项定义到根 (root) 文件系统的路径,通常是 NFS 符号。当使用 PXE 时,只要您不启用内核里的 BOOTP 选项,可以不管主机的IP。NFS 服务器然后就如同 TFTP 一样。 配置使用BOOTP BOOTP 无盘操作 这里紧跟的是一个等效的 bootpd 配置 (减少到一个客户端)。这个可以在 /etc/bootptab 里找到。 请注意:为了使用BOOTP,etherboot 必须使用非默认选项 NO_DHCP_SUPPORT 来进行编译,而且 PXE 需要 DHCPbootpd 的唯一可见的好处是它存在于基本系统中。 .def100:\ :hn:ht=1:sa=192.168.4.4:vm=rfc1048:\ :sm=255.255.255.0:\ :ds=192.168.4.1:\ :gw=192.168.4.1:\ :hd="/tftpboot":\ :bf="/kernel.diskless":\ :rp="192.168.4.4:/data/misc/diskless": margaux:ha=0123456789ab:tc=.def100 使用<application>Etherboot</application>准备启动程序 Etherboot Etherboot 的网站 包含有更多的文档 ——主要瞄准的是 Linux 系统,但无疑包含有有用的信息。 如下列出的是关于在 FreeBSD 系统里使用 Etherboot 首先您必须安装net/etherboot 包或 port。 您可以改变 Etherboot 的配置 (如使用 TFTP 来代替 NFS), 方法是修改 Config 文件——在 Etherboot 源目录里。 对于我们的设置,我们要使用一张启动软盘。 对于其它的方法(PROM,或 &ms-dos;程序), 请参考 Etherboot 文档。 想要使用启动软盘,先插入一张软盘到安装有 Etherboot 的机器的驱动器里, 然后把当前路径改到 src 目录——在 Etherboot 树下, 接着输入: &prompt.root; gmake bin32/devicetype.fd0 devicetype 依赖于无盘工作站上的以太网卡的类型。 参考在同一个目录下的 NIC 文件确认正确的 devicetype 使用<acronym>PXE</acronym>启动 默认地,&man.pxeboot.8; 装载器通过 NFS 装载内核。它可以编译来使用 TFTP——通过在文件 /etc/make.conf 里指定 LOADER_TFTP_SUPPORT 选项来代替。 请参见 /usr/share/examples/etc/make.conf 里的注释 了解如何配置。 除此之外还有两个未说明的 make.conf 选项——它可能对于设置一系列控制台无盘机器会有用: BOOT_PXELDR_PROBE_KEYBOARDBOOT_PXELDR_ALWAYS_SERIAL 当机器启动里,要使用 PXE, 通常需要选择 Boot from network 选项——在 BIOS 设置里, 或者在 PC 初始化的时候输入一个功能键 (function key)。 配置 <acronym>TFTP</acronym> 和 <acronym>NFS</acronym> 服务器 TFTP 无盘操作 NFS 无盘操作 如果您正在使用 PXEEtherboot——配置使用了 TFTP,那么您需要在文件服务器上启用 tftpd 建立一个目录——从那里 tftpd 可以提供文件服务,如 /tftpboot 把这一行加入到 /etc/inetd.conf里: tftp dgram udp wait root /usr/libexec/tftpd tftpd -l -s /tftpboot 好像有一些版本的 PXE 需要 TCP 版本的 TFTP。 在这种情况下,加入第二行,使用 stream tcp 来代替 dgram udp inetd 重读其配置文件。 要正确执行这个命令, 在 /etc/rc.conf 文件中必须加入 &prompt.root; /etc/rc.d/inetd restart 您可把 tftpboot 目录放到服务器上的什何地方。 确定这个位置设置在 inetd.confdhcpd.conf 里。 在所有的情况下,您都需要启用 NFS, 并且 NFS 服务器上导出相应的文件系统。 把这一行加入到/etc/rc.conf里: nfs_server_enable="YES" 通过往 /etc/exports 里加入下面几行(调整载入点列, 并且使用无盘工作站的名字替换 margaux corbieres), 导出文件系统——无盘根目录存在于此: /data/misc -alldirs -ro margaux corbieres mountd 重读它的配置文件。如果您真的需要启用第一步的 /etc/rc.confNFS, 您可能就要重启系统了。 &prompt.root; /etc/rc.d/mountd restart 建立无盘内核 无盘操作 内核配置 如果您在使用 Etherboot, 您需要为无盘客户端建立内核配置文件, 使用如下选项(除了常使用的外): options BOOTP # Use BOOTP to obtain IP address/hostname options BOOTP_NFSROOT # NFS mount root filesystem using BOOTP info 您可能也想使用 BOOTP_NFSV3BOOT_COMPATBOOTP_WIRED_TO (参考 NOTES 文件)。 这些名字具有历史性,并且有些有些误导, 因为它们实际上启用了内核里 (它可能强制限制 BOOTP 或 DHCP 的使用),与 DHCP 和 BOOTP 的无关的应用。 编译内核(参考), 然后将它复制到 dhcpd.conf 里指定的地方。 当使用 PXE 里, 使用以上选项建立内核并不做严格要求(尽管建议这样做)。 启用它们会在内核启动时引起更多的 DHCP 提及过的请求,带来的小小的风险是在有些特殊情况下新值和由 &man.pxeboot.8; 取回的值之间的不一致性。 使用它们的好处是主机名会被附带设置。否则, 您就需要使用其它的方法来设置主机名,如在客户端指定的 rc.conf 文件里。 为了使带有 Etherboot 的内核可引导,就需要把设备提示 (device hint) 编译进去。通常要在配置文件(查看 NOTES 配置注释文件) 里设置下列选项: hints "GENERIC.hints" 准备根(root)文件系统 根文件系统 无盘操作 您需要为无盘工作站建立根文件系统, 它就是 dhcpd.conf 里的 root-path 所指定的目录。 使用 <command>make world</command> 来复制根文件系统 这种方法可以迅速安装一个彻底干净的系统 (不仅仅是根文件系统) 到 DESTDIR。 您要做的就是简单地执行下面的脚本: #!/bin/sh export DESTDIR=/data/misc/diskless mkdir -p ${DESTDIR} cd /usr/src; make buildworld && make buildkernel cd /usr/src/etc; make distribution 一旦完成,您可能需要定制 /etc/rc.conf/etc/fstab——根据您的需要放到 DESTDIR里。 配置 swap(交换) 如果需要,位于服务器上的交换文件可以通过 NFS 来访问。 <acronym>NFS</acronym> 交换区 内核并不支持在引导时启用 NFS 交换区。 交换区必须通过启动脚本启用, 其过程是挂接一个可写的文件系统, 并在其上创建并启用交换文件。 要建立尺寸合适的交换文件, 可以这样做: &prompt.root; dd if=/dev/zero of=/path/to/swapfile bs=1k count=1 oseek=100000 要启用它,您须要把下面几行加到 rc.conf里: swapfile=/path/to/swapfile 杂项问题 运行时 <filename>/usr</filename> 是只读在 无盘操作 只读的 /usr 如果无盘工作站是配置来支持 X, 那么您就必须调整 XDM 配置文件,因为它默认把错误信息写到 /usr 使用非 FreeBSD 服务器 当用作根文件系统的服务器运行的是不 FreeBSD,您须要在 FreeBSD 机器上建立根文件系统, 然后把它复制到它的目的地,使用的命令可以是 tarcpio 在这种情况下,有时对于 /dev 里的一些特殊的文件会有问题,原因就是不同的 最大/最小整数大小。 一种解决的方法就是从非 FreeBSD 服务里导出一个目录, 并把它载入 FreeBSD 到机子上, 并使用 &man.devfs.5; 来为用户透明地分派设备节点。
ISDN ISDN 关于 ISDN 技术和硬件的一个好的资源是Dan Kegel 的 ISDN 主页 一个快速简单的到 ISDN 的路线图如下: 如果您住在欧洲,您可能要查看一下 ISDN 卡部分。 如果您正计划首要地使用 ISDN 基于拨号非专用线路连接到带有提供商的互联网, 您可能要了解一下终端适配器。如果您更改提供商的话, 这会给您带来最大的灵活性、最小的麻烦。 如果您连接了两个局域网 (LAN),或使用了专用的 ISDN 连线连接到互联网,您可能要考虑选择单独的路由器/网桥。 在决定选择哪一种方案的时候,价格是个很关键的因素。 下面列有从不算贵到最贵的选择: Hellmuth Michaelis 贡献者: 雪平 中文翻译:
zxpmyth@yahoo.com.cn
ISDN 卡 ISDN FreeBSD 的 ISDN 工具通过被动卡 (passive card) 仅支持 DSS1/Q.931(或 Euro-ISDN) 标准。 此外也支持一些 active card, 它们的固件也支持其它信号协议, 这其中包括最先得到支持的 Primary Rate (PRI) ISDN卡。 isdn4bsd 软件允许连接到其它 ISDN 路由器,使用的是原始的 HDLC 上的 IP 或利用同步 PPP:使用带有 isppp (一个修改过的 &man.sppp.4; 驱动程序)的 PPP 内核,或使用用户区 (userland) &man.ppp.8;。通过使用 userland &man.ppp.8;,两个或更多 ISDN 的 B 通道联结变得可能。 除了许多如 300 波特 (Baud) 的软 modem 一样的工具外, 还可以实现电话应答机应用。 在 FreeBSD 里,正有更多的 PC ISDN 卡被支持; 报告显示在整个欧洲及世界的其它许多地区可以成功使用。 被支持的主动型 ISDN 卡主要是带有 Infineon (以前的 Siemens) ISAC/HSCX/IPAC ISDN 芯片组,另外还有带有 Cologne (只有 ISA 总线) 芯片的 ISDN 卡、带有 Winbond W6692 芯片的 PCI 卡、一部分带有 Tiger300/320/ISAC 芯片组的卡以及带有一些商家专有的芯片组的卡 (如 AVM Fritz!Card PCI V.1.0 和 the AVM Fritz!Card PnP)。 当前积极的支持的 ISDN 卡有 AVM B1 (ISA 和 PCI) BRI 卡和 AVM T1 PCI PRI 卡。 关于 isdn4bsd 的文档,请查看 FreeBSD 系统里的 /usr/share/examples/isdn/ 目录或查看 isdn4bsd的主页, 那里也有提示、勘误表以及更多的文档 (如 isdn4bsd手册)。 要是您有兴趣增加对不同 ISDN 协议的支持,对当前还不支持的 ISDN PC 卡的支持或想增强 isdn4bsd 的性能,请联系 &a.hm;。 对于安装、配置以及 isdn4bsd 故障排除的问题,可以利用 &a.isdn.name; 邮件列表。
ISDN 终端适配器 终端适配器 (TA) 对于 ISDN 就好比 modem 对于常规电话线。 modem 许多 TA 使用标准的 Hayes modem AT 命令集,并且可以降级来代替 modem。 TA 基本的运作同 modem 一样,不同之处是连接和整个速度更比老 modem 更快。同 modem 的安装一样,您也需要配置 PPP。确认您的串口速度已足够高。 PPP 使用 TA 连接互联网提供商的主要好处是您可以做动态的 PPP。 由于 IP 地址空间变得越来越紧张,许多提供商都不愿再提供静态 IP。许多的独立的路由器是不支持动态 IP 分配的。 TA 完全依赖于您在运行的 PPP 进程, 以完成它们的功能和稳定的连接。这可以让您在 FreeBSD 机子里轻易地从使用 modem 升级到 ISDN,要是您已经安装了 PPP 的话。只是,在您使用 PPP 程序时所体验到任何问题同时也存在。 如果您想要最大的稳定性,请使用 PPP 内核选项,而不要使用 userland PPP。 下面的 TA 就可以同 FreeBSD 一起工作: Motorola BitSurfer 和 Bitsurfer Pro Adtran 大部分其它的 TA 也可能工作,TA 提供商试图让他们的产品可以接受大部分的标准 modem AT 命令集。 对于外置 TA 的实际问题是:象 modem 要一样,您机子需要有一个好的串行卡。 想要更深入地理解串行设备以及异步和同步串口这间的不同点, 您就要读读 FreeBSD 串行硬件教程了。 TA 将标准的 PC 串口 (同步的) 限制到了 115.2 Kbs,即使您有 128 Kbs 的连接。 想要完全利用 ISDN 有能力达到的 128 Kbs,您就需要把 TA 移到同步串行卡上。 当心被骗去买一个内置的 TA 以及自认为可以避免同步/异步问题。内置的 TA 只是简单地将一张标准 PC 串口芯片内建在里边。 所做的这些只是让您省去买另一根串行线以及省去寻找另一个空的插孔。 带有 TA 的同步卡至少和一个独立的路由器同一样快地, 而且仅使用一个简单的 386 FreeBSD 盒驱动它。 选择同步卡/TA 还是独立的路由器,是个要高度谨慎的问题。 在邮件列表里有些相关的讨论。我们建议您去搜索一下关于完整讨论的记录 单独的 ISDN 桥/路由器 ISDN 单独的 桥/路由器 ISDN 桥或路由器根本就没有指定要 FreeBSD 或其它任何的操作系统。更多完整的关于路由和桥接技术的描述, 请参考网络指南的书籍。 这部分的内容里,路由器和桥接这两个词汇将会交替地使用。 随着 ISDN 路由器/桥的价格下滑,对它们的选择也会变得越来越流行。 ISDN 路由器是一个小盒子,可以直接地接入您的本地以太网, 并且自我管理到其它桥/路由器的连接。它有个内建的软件用于与通信——通过 PPP 和其它流行的协议。 路由器有比标准 TA 更快的吞吐量,因为它会使用完全同步的 ISDN 连接。 使用 ISDN 路由器和桥的主要问题是两个生产商之间的协同性仍存在问题。 如果您计划连接到互联网提供商,您应该跟他们进行交涉。 如果您计划连接两个局域网网段,如您的家庭网和办公网, 这将是最简单最低维护的解决方案。因为您买的设备是用于连接两边的, 可以保证这种连接一定会成功。 例如连接到家里的计算机,或者是办公网里的一个分支连接到办公主网, 那么下面的设置就可能用到: 办公室局部或家庭网 10 base 2 网络使用基于总线拓扑的 10 base 2 以太网 (瘦网(thinnet))。如果有必要,用网线连接路由器和 AUI/10BT 收发器。 ---Sun workstation | ---FreeBSD box | ---Windows 95 | Stand-alone router | ISDN BRI line 10 Base 2 Ethernet 如果您的家里或办公室支部里只有一台计算机, 您可以使用一根交叉的双绞线直接连接那台独立路由器。 主办公室或其它网络 10 base T 网络使用的是星形拓扑的 10 base T 以太网(双绞线)。 -------Novell Server | H | | ---Sun | | | U ---FreeBSD | | | ---Windows 95 | B | |___---Stand-alone router | ISDN BRI line ISDN Network Diagram 大部分路由器/网桥有一大好处就是,它们允许您在 同一 时间,有两个 分开独立的 PPP 连接到两个分开的点上。这点在许多的 TA 上是不支持的, 除非带有两个串口的特定模式(通常都很贵)。请不要把它与通道连接、MPP 等相混淆。 这是个非常有用的功能,例如,如果在您的办公室里您有个专有的 ISDN 连接,而且您想接入到里边,但休想让另一根 ISDN 线也能工作。 办公室里的路由器能够管理专有的B通道连接到互联网 (64 Kbps) 以及使用另一个通道 B 来完成单独的数据连接。 第二个 B 通道可以用于拨进、拨出或动态与第一个B通道进行连接 (MPP等),以获取更大宽带。 IPX/SPX 以太网桥也允许您传输的不仅仅是 IP 通信。您也可以发送 IPX/SPX 或其它任何您所使用的协议。
Chern Lee 作者: 译者:
delphij@FreeBSD.org.cn
网络地址转换 概要 natd FreeBSD 的网络地址转换服务, 通常也被叫做 &man.natd.8;, 是一个能够接收连入的未处理 IP 包, 将源地址修改为本级地址然后重新将这些包注入到发出 IP 包流中。 &man.natd.8; 同时修改源地址和端口, 当接收到响应数据时,它作逆向转换以便把数据发回原先的请求者。 Internet 连接共享 NAT NAT 最常见的用途是为人们所熟知的 Internet 连接共享。 安装 随着 IPv4 的 IP 地址空间的日益枯竭, 以及使用如 DSL 和电缆等高速连接的用户的逐渐增多, 越来越多的人开始需要 Internet 连接共享这样的解决方案。 由于能够将许多计算机通过一个对外的 IP 地址进行接入, &man.natd.8; 成为了一个理想的选择。 更为常见的情况, 一个用户通过电缆或者 DSL 线路 接入,并拥有一个 IP 地址,同时,希望通过这台接入 Internet 的计算机来为 LAN 上更多的计算机提供接入服务。 为了完成这一任务, 接入 Internet 的 FreeBSD 机器必须扮演网关的角色。 这台网关必须有两块网卡 — 一块用于连接 Internet 路由器, 另一块用来连接 LAN。 所有 LAN 上的机器通过 Hub 或交换机进行连接。 有多种方法能够通过 &os; 网关将 LAN 接入 Internet。 这个例子只介绍了有至少两块网卡的网关。 _______ __________ ________ | | | | | | | Hub |-----| Client B |-----| Router |----- Internet |_______| |__________| |________| | ____|_____ | | | Client A | |__________| Network Layout 上述配置被广泛地用于共享 Internet 连接。 LAN 中的一台机器连接到 Internet 中。 其余的计算机则通过那台 网关 机来连接 Internet。 内核 配置 配置 下面这些选项必须放到内核配置文件中: options IPFIREWALL options IPDIVERT 此外,下列是一些可选的选项: options IPFIREWALL_DEFAULT_TO_ACCEPT options IPFIREWALL_VERBOSE 这些配置必须放到 /etc/rc.conf 中: gateway_enable="YES" firewall_enable="YES" firewall_type="OPEN" natd_enable="YES" natd_interface="fxp0" natd_flags="" 将机器配置为网关。 执行 sysctl net.inet.ip.forwarding=1 效果相同。 在启动时启用 /etc/rc.firewall 中的防火墙规则。 指定一个预定义的允许所有包进入的防火墙规则集。 参见 /etc/rc.firewall 以了解其他类型的规则集。 指定通过哪个网络接口转发包 (接入 Internet 的那一个)。 其他希望在启动时传递给 &man.natd.8; 的参数。 /etc/rc.conf 中加入上述选项将在系统启动时运行 natd -interface fxp0。 这一工作也可以手工完成。 当有太多选项要传递时,也可以使用一个 &man.natd.8; 的配置文件来完成。这种情况下,这个配置文件必须通过在 /etc/rc.conf 里增加下面内容来定义: natd_flags="-f /etc/natd.conf" /etc/natd.conf 文件会包含一个配置选项列表, 每行一个。在紧跟部分的例子里将使用下面的文件: redirect_port tcp 192.168.0.2:6667 6667 redirect_port tcp 192.168.0.3:80 80 关于配置文件的更多信息,参考 &man.natd.8; 手册页中关于 选项那一部分。 在LAN后面的每一台机子和接口应该被分配私有地址空间(由RFC 1918定义) 里的 IP 地址,并且默认网关设成 natd 机子的内连 IP 地址。 例如:客户端 AB 在 LAN 后面,IP 地址是 192.168.0.2192.168.0.3,同时 natd 机子的 LAN 接口上的 IP 地址是 192.168.0.1。客户端 AB 的默认网关必须要设成 natd 机子的 IP——192.168.0.1natd 机子外连,或互联网接口不需要为了 &man.natd.8; 而做任何特别的修改就可工作。 端口重定向 使用 &man.natd.8; 的缺点就是 LAN 客户不能从互联网访问。LAN 上的客户可以进行到外面的连接,而不能接收进来的连接。如果想在 LAN 的客户端机子上运行互联网服务,这就会有问题。 对此的一种简单方法是在 natd 机子上重定向选定的互联网端口到 LAN 客户端。 例如:在客户端 A 上运行 IRC 服务,而在客户端 B 上运行 web 服务。 想要正确的工作,在端口 6667 (IRC) 和 80 (web) 上接收到的连接就必须重定向到相应的机子上。 需要使用适当的选项传送给 &man.natd.8;。语法如下: -redirect_port proto targetIP:targetPORT[-targetPORT] [aliasIP:]aliasPORT[-aliasPORT] [remoteIP[:remotePORT[-remotePORT]]] 在上面的例子中,参数应该是: -redirect_port tcp 192.168.0.2:6667 6667 -redirect_port tcp 192.168.0.3:80 80 这就会重定向适当的 tcp 端口到 LAN 上的客户端机子。 参数可以用来指出端口范围来代替单个端口。例如, tcp 192.168.0.2:2000-3000 2000-3000 就会把所有在端口 2000 到 3000 上接收到的连接重定向到主机 A 上的端口 2000 到 3000。 当直接运行 &man.natd.8; 时,就可以使用这些选项, 把它们放到 /etc/rc.conf 里的 natd_flags="" 选项上, 或通过一个配置文件进行传送。 想要更多配置选项,请参考 &man.natd.8;。 地址重定向 地址重定向 如果有几个 IP 地址提供,那么地址重定向就会很有用, 然而他们必须在一个机子上。使用它,&man.natd.8; 就可以分配给每一个 LAN 客户端它们自己的外部 IP 地址。&man.natd.8; 然后会使用适当的处部 IP 地址重写从 LAN 客户端外出的数据包, 以及重定向所有进来的数据包——一定的 IP 地址回到特定的 LAN 客户端。这也叫做静态 NAT。例如,IP 地址 128.1.1.1128.1.1.2128.1.1.3 属于 natd 网关机子。 128.1.1.1 可以用来作 natd 网关机子的外连 IP 地址,而 128.1.1.2128.1.1.3 用来转发回 LAN 客户端 AB 语法如下: -redirect_address localIP publicIP localIP LAN 客户端的内部 IP 地址。 publicIP 相应 LAN 客户端的外部 IP 地址。 在这个例子里,参数是: -redirect_address 192.168.0.2 128.1.1.2 -redirect_address 192.168.0.3 128.1.1.3 一样,这些参数也是放在 /etc/rc.conf 里的 natd_flags="" 选项上, 或通过一个配置文件传送给它。使用地址重定向, 就没有必要用端口重定向了,因为所有在某个 IP 地址上收到的数据都被重定向了。 natd 机子上的外部 IP 地址必须激活并且别名到 (aliased) 外连接口。要这做就看看 &man.rc.conf.5;。
并口电缆 IP (PLIP) PLIP 并口电缆 IP PLIP PLIP 允许我们在两个并口间运行 TCP/IP。 在使用笔记本电脑, 或没有网卡的计算机时, 这会非常有用。 这一节中, 我们将讨论: 制作用于并口的 (laplink) 线缆。 使用 PLIP 连接两台计算机。 制作并口电缆。 您可以在许多计算机供应店里买到并口电缆。 如果买不到, 或者希望自行制作, 则可以参阅下面的表格, 它介绍了如何利用普通的打印机并口电缆来改制: 用于网络连接的并口电缆接线方式A-name A 端 B 端 描述 Post/BitDATA0 -ERROR 2 15 15 2 数据 0/0x01 1/0x08DATA1 +SLCT 3 13 13 3 数据 0/0x02 1/0x10DATA2 +PE 4 12 12 4 数据 0/0x04 1/0x20DATA3 -ACK 5 10 10 5 脉冲 (Strobe) 0/0x08 1/0x40DATA4 BUSY 6 11 11 6 数据 0/0x10 1/0x80GND 18-25 18-25 GND -
设置 PLIP 首先,您需要一根 laplink 线。然后, 确认两台计算机的内核都有对 &man.lpt.4; 驱动程序的支持: &prompt.root; grep lp /var/run/dmesg.boot lpt0: <Printer> on ppbus0 lpt0: Interrupt-driven port 并口必须是一个中断驱动的端口, 您应在 /boot/device.hints 文件中配置: hint.ppc.0.at="isa" hint.ppc.0.irq="7" 然后检查内核配置文件中是否有一行 device plip 或加载了 plip.ko 内核模块。 这两种情况下, 在使用 &man.ifconfig.8; 命令时都会显示并口对应的网络接口, 类似这样: &prompt.root; ifconfig plip0 plip0: flags=8810<POINTOPOINT,SIMPLEX,MULTICAST> mtu 1500 用 laplink 线接通两台计算机的并口。 在两边以 root 身份配置通讯参数。 例如, 如果你希望将 host1 通过另一台机器 host2 连接: host1 <-----> host2 IP Address 10.0.0.1 10.0.0.2 配置 host1 上的网络接口,照此做: &prompt.root; ifconfig plip0 10.0.0.1 10.0.0.2 配置 host2 上的网络接口,照此做: &prompt.root; ifconfig plip0 10.0.0.2 10.0.0.1 您现在应该有个工作的连接了。想要更详细的信息, 请阅读 &man.lp.4; 和 &man.lpt.4; 手册页。 您还应该增加两个主机到 /etc/hosts 127.0.0.1 localhost.my.domain localhost 10.0.0.1 host1.my.domain host1 10.0.0.2 host2.my.domain host2 要确认连接是否工作,可以到每一台机子上,然后 ping 另外一台。例如,在 host1 上: &prompt.root; ifconfig plip0 plip0: flags=8851<UP,POINTOPOINT,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet 10.0.0.1 --> 10.0.0.2 netmask 0xff000000 &prompt.root; netstat -r Routing tables Internet: Destination Gateway Flags Refs Use Netif Expire host2 host1 UH 0 0 plip0 &prompt.root; ping -c 4 host2 PING host2 (10.0.0.2): 56 data bytes 64 bytes from 10.0.0.2: icmp_seq=0 ttl=255 time=2.774 ms 64 bytes from 10.0.0.2: icmp_seq=1 ttl=255 time=2.530 ms 64 bytes from 10.0.0.2: icmp_seq=2 ttl=255 time=2.556 ms 64 bytes from 10.0.0.2: icmp_seq=3 ttl=255 time=2.714 ms --- host2 ping statistics --- 4 packets transmitted, 4 packets received, 0% packet loss round-trip min/avg/max/stddev = 2.530/2.643/2.774/0.103 ms
Aaron Kaplan 原始作者: Tom Rhodes 重新组织和增加: 雪平 中文翻译:
zxpmyth@yahoo.com.cn
Brad Davis Extended by
IPv6 IPv6 (也被称作 IPng 下一代 IP) 是众所周知的 IP 协议 (也叫 IPv4) 的新版本。 和其他现代的 *BSD 系统一样, FreeBSD 包含了 KAME 的 IPv6 参考实现。 因此, 您的 FreeBSD 系统包含了尝试 IPv6 所需要的所有工具。 这一节主要集中讨论如何配置和使用 IPv6。 在 1990 年代早期, 人们开始担心可用的 IPv4 地址空间在不断地缩小。 随着 Internet 的爆炸式发展, 主要的两个担心是: 用尽所有的地址。 当然现在这个问题已经不再那样尖锐, 因为 RFC1918 私有地址空间 (10.0.0.0/8172.16.0.0/12, 以及 192.168.0.0/16) 和网络地址转换 (NAT) 技术已经被广泛采用。 路由表条目变得太大。这点今天仍然是焦点。 IPv6 解决这些和其它许多的问题: 128 位地址空间。换句话,理论上有 340,282,366,920,938,463,463,374,607,431,768,211,456 个地址可以使用。这意味着在我们的星球上每平方米大约有 6.67 * 10^27 个 IPv6 地址。 路由器仅在它们的路由表里存放网络地址集, 这就减少路由表的平均空间到 8192 个条目。 IPv6 还有其它许多有用的功能,如: 地址自动配置 (RFC2462) Anycast (任意播) 地址(一对多) 强制的多播地址 IPsec (IP 安全) 简单的头结构 移动的 (Mobile) IP IPv6 到 IPv4 的转换机制 要更多信息,请查看: IPv6 概观,在 playground.sun.com KAME.net 关于 IPv6 地址的背景知识 有几种不同类型的 IPv6 地址:Unicast,Anycast 和 Multicast。 Unicast 地址是为人们所熟知的地址。一个被发送到 unicast 地址的包实际上会到达属于这个地址的接口。 Anycast 地址语义上与 unicast 地址没有差别, 只是它们强调一组接口。指定为 anycast 地址的包会到达最近的 (以路由为单位) 接口。Anycast 地址可能只被路由器使用。 Multicast 地址标识一组接口。指定为 multicast 地址的包会到达属于 multicast 组的所有的接口。 IPv4 广播地址 (通常为 xxx.xxx.xxx.255) 由 IPv6 的 multicast 地址来表示。 保留的 IPv6 地址 IPv6 地址 预定长度 (bits) 描述 备注 :: 128 bits 未指定 类似 IPv4 中的 0.0.0.0 ::1 128 bits 环回地址 类似 IPv4 中的 127.0.0.1 ::00:xx:xx:xx:xx 96 bits 嵌入的 IPv4 低 32 bits 是 IPv4 地址。这也称作 IPv4 兼容 IPv6 地址 ::ff:xx:xx:xx:xx 96 bits IPv4 影射的 IPv6 地址 低的 32 bits 是 IPv4 地址。 用于那些不支持 IPv6 的主机。 fe80:: - feb:: 10 bits 链路环回 类似 IPv4 的环回地址。 fec0:: - fef:: 10 bits 站点环回   ff:: 8 bits 多播   001 (base 2) 3 bits 全球多播 所有的全球多播地址都指定到这个地址池中。前三个二进制位是 001
IPv6 地址的读法 规范形式被描述为:x:x:x:x:x:x:x:x, 每一个x就是一个 16 位的 16 进制值。当然, 每个十六进制块以三个0开始头的也可以省略。如 FEBC:A574:382B:23C1:AA49:4592:4EFE:9982 通常一个地址会有很长的子串全部为零, 因此每个地址的这种子串常被简写为::。 例如:fe80::1 对应的规范形式是 fe80:0000:0000:0000:0000:0000:0000:0001 第三种形式是以众所周知的用点.作为分隔符的十进制 IPv4 形式,写出最后 32 Bit 的部分。例如 2002::10.0.0.1 对应的十进制正规表达方式是 2002:0000:0000:0000:0000:0000:0a00:0001 它也相当于写成 2002::a00:1. 到现在,读者应该能理解下面的内容了: &prompt.root; ifconfig rl0: flags=8943<UP,BROADCAST,RUNNING,PROMISC,SIMPLEX,MULTICAST> mtu 1500 inet 10.0.0.10 netmask 0xffffff00 broadcast 10.0.0.255 inet6 fe80::200:21ff:fe03:8e1%rl0 prefixlen 64 scopeid 0x1 ether 00:00:21:03:08:e1 media: Ethernet autoselect (100baseTX ) status: active fe80::200:21ff:fe03:8e1%rl0 是一个自动配置的链路环回地址。它作为自动配置的一部分由 MAC 生成。 关于 IPv6 地址的结构的更多信息,请参看 RFC3513 进行连接 目前,有四种方式可以连接到其它 IPv6 主机和网络: 咨询你的互联网服务提供商是否提供 IPv6。 SixXS 向全球范围提供通道。 使用 6-to-4 通道 (RFC3068) 如果您使用的是拨号连接, 则可以使用 net/freenet6 port。 IPv6 世界里的 DNS 对于 IPv6 有两种类型的 DNS 记录:IETF 已经宣布 A6 是过时标准;现行的标准是 AAAA 记录。 使用AAAA记录是很简单的。通过增加下面内容, 给您的主机分配置您刚才接收到的新的 IPv6 地址: MYHOSTNAME AAAA MYIPv6ADDR 到您的主域 DNS 文件里,就可以完成。要是您自已没有 DNS 域服务,您可以询问您的 DNS 提供商。目前的 bind 版本 (version 8.3 与 9) 和 dns/djbdns(含IPv6补丁) 支持 AAAA 记录。 在 <filename>/etc/rc.conf</filename> 中进行所需的修改 IPv6 客户机设置 这些设置将帮助您把一台您 LAN 上的机器配置为一台客户机, 而不是路由器。 要让 &man.rtsol.8; 在启动时自动配置您的网卡, 只需添加: ipv6_enable="YES" 要自动地静态指定 IP 地址, 例如 2001:471:1f11:251:290:27ff:fee0:2093, 到 fxp0 上, 则写上: ipv6_ifconfig_fxp0="2001:471:1f11:251:290:27ff:fee0:2093" 要指定 2001:471:1f11:251::1 作为默认路由, 需要在 /etc/rc.conf 中加入: ipv6_defaultrouter="2001:471:1f11:251::1" IPv6 路由器/网关配置 这将帮助您从隧道提供商那里取得必要的资料, 并将这些资料转化为在重启时能够保持住的设置。 要在启动时恢复您的隧道, 需要在 /etc/rc.conf 中增加: 列出要配置的通用隧道接口, 例如 gif0 gif_interfaces="gif0" 配置该接口使用本地端地址 MY_IPv4_ADDR 和远程端地址 REMOTE_IPv4_ADDR gifconfig_gif0="MY_IPv4_ADDR REMOTE_IPv4_ADDR" 应用分配给您用于 IPv6 隧道远端的 IPv6 地址, 需要增加: ipv6_ifconfig_gif0="MY_ASSIGNED_IPv6_TUNNEL_ENDPOINT_ADDR" 此后十设置 IPv6 的默认路由。 这是 IPv6 隧道的另一端: ipv6_defaultrouter="MY_IPv6_REMOTE_TUNNEL_ENDPOINT_ADDR" IPv6 隧道配置 如果服务器将您的网络通过 IPv6 路由到世界的其他角落, 您需要在 /etc/rc.conf 中添加下面的配置: ipv6_gateway_enable="YES" 路由宣告和主机自动配置 这节将帮助您配置 &man.rtadvd.8; 来宣示默认的 IPv6 路由。 要启用 &man.rtadvd.8; 您需要在 /etc/rc.conf 中添加: rtadvd_enable="YES" 指定由哪个网络接口来完成 IPv6 路由请求非常重要。 举例来说, 让 &man.rtadvd.8; 使用 fxp0 rtadvd_interfaces="fxp0" 接下来我们需要创建配置文件, /etc/rtadvd.conf。 示例如下: fxp0:\ :addrs#1:addr="2001:471:1f11:246::":prefixlen#64:tc=ether: fxp0 改为您打算使用的接口名。 接下来, 将 2001:471:1f11:246:: 改为分配给您的地址前缀。 如果您拥有专用的 /64 子网, 则不需要修改其他设置。 反之, 您需要把 prefixlen# 改为正确的值。
Harti Brandt 贡献者: 雪平 中文翻译:
zxpmyth@yahoo.com.cn
异步传输模式 (ATM) 配置 classical IP over ATM (PVCs) Classical IP over ATM (CLIP) 是一种最简单的使用带 IP 的 ATM 的方法。 这种方法可以用在交换式连接 (SVC) 和永久连接 (PVC) 上。这部分描述的就是配置基于 PVC 的网络。 完全互连的配置 第一种使用PVC来设置 CLIP 的方式就是通过专用的 PVC 让网络里的每一台机子都互连在一起。 尽管这样配置起来很简单,但对于数量更多一点的机子来说就有些不切实际了。 例如我们有四台机子在网络里,每一台都使用一张 ATM 适配器卡连接到 ATM 网络。第一步就是规划 IP 地址和机子间的 ATM 连接。我们使用下面的: 主机 IP 地址 hostA 192.168.173.1 hostB 192.168.173.2 hostC 192.168.173.3 hostD 192.168.173.4 为了建造完全交错的网络,我们需要在第一对机子间有一个 ATM 连接: 机器 VPI.VCI 对 hostA - hostB 0.100 hostA - hostC 0.101 hostA - hostD 0.102 hostB - hostC 0.103 hostB - hostD 0.104 hostC - hostD 0.105 在每一个连接端 VPI 和 VCI 的值都可能会不同, 只是为了简单起见,我们假定它们是一样的。 下一步我们需要配置每一个主机上的 ATM 接口: hostA&prompt.root; ifconfig hatm0 192.168.173.1 up hostB&prompt.root; ifconfig hatm0 192.168.173.2 up hostC&prompt.root; ifconfig hatm0 192.168.173.3 up hostD&prompt.root; ifconfig hatm0 192.168.173.4 up 假定所有主机上的 ATM 接口都是 hatm0。 现在 PVC 需要配置到 hostA 上 (我们假定它们都已经配置在了 ATM 交换机上,至于怎么做的, 您就需要参考一下该交换机的手册了)。 hostA&prompt.root; atmconfig natm add 192.168.173.2 hatm0 0 100 llc/snap ubr hostA&prompt.root; atmconfig natm add 192.168.173.3 hatm0 0 101 llc/snap ubr hostA&prompt.root; atmconfig natm add 192.168.173.4 hatm0 0 102 llc/snap ubr hostB&prompt.root; atmconfig natm add 192.168.173.1 hatm0 0 100 llc/snap ubr hostB&prompt.root; atmconfig natm add 192.168.173.3 hatm0 0 103 llc/snap ubr hostB&prompt.root; atmconfig natm add 192.168.173.4 hatm0 0 104 llc/snap ubr hostC&prompt.root; atmconfig natm add 192.168.173.1 hatm0 0 101 llc/snap ubr hostC&prompt.root; atmconfig natm add 192.168.173.2 hatm0 0 103 llc/snap ubr hostC&prompt.root; atmconfig natm add 192.168.173.4 hatm0 0 105 llc/snap ubr hostD&prompt.root; atmconfig natm add 192.168.173.1 hatm0 0 102 llc/snap ubr hostD&prompt.root; atmconfig natm add 192.168.173.2 hatm0 0 104 llc/snap ubr hostD&prompt.root; atmconfig natm add 192.168.173.3 hatm0 0 105 llc/snap ubr 当然,除 UBR 外其它的通信协定也可让 ATM 适配器支持这些。 此种情况下,通信协定的名字要跟人通信参数后边。工具 &man.atmconfig.8; 的帮助可以这样得到: &prompt.root; atmconfig help natm add 或者在 &man.atmconfig.8; 手册页里得到。 相同的配置也可以通过 /etc/rc.conf 来完成。对于 hostA,看起来就象这样: network_interfaces="lo0 hatm0" ifconfig_hatm0="inet 192.168.173.1 up" natm_static_routes="hostB hostC hostD" route_hostB="192.168.173.2 hatm0 0 100 llc/snap ubr" route_hostC="192.168.173.3 hatm0 0 101 llc/snap ubr" route_hostD="192.168.173.4 hatm0 0 102 llc/snap ubr" 所有 CLIP 路由的当前状态可以使用如下命令获得: hostA&prompt.root; atmconfig natm show
Tom Rhodes 原作 Common Access Redundancy Protocol (CARP, 共用地址冗余协议) CARP Common Access Redundancy Protocol, 共用地址冗余协议 Common Access Redundancy Protocol, 或简称 CARP 能够使多台主机共享同一 IP 地址。 在某些配置中, 这样做可以提高可用性, 或实现负载均衡。 下面的例子中, 这些主机也可以同时使用其他的不同的 IP 地址。 要启用 CARP 支持, 必须在 &os; 内核配置中增加下列选项, 并重新联编内核: device carp 这样就可以使用 CARP 功能了, 一些具体的参数, 可以通过一系列 sysctl OID 来调整。 OID 描述 net.inet.carp.allow 接受进来的 CARP 包。 默认启用。 net.inet.carp.preempt 当主机中有一个 CARP 网络接口失去响应时, 这个选项将停止这台主机上所有的 CARP 接口。 默认禁用。 net.inet.carp.log 当值为 0 表示禁止记录所有日志。 值为 1 表示记录损坏的 CARP 包。任何大于 1 表示记录 CARP 网络接口的状态变化。默认值为 1 net.inet.carp.arpbalance 使用 ARP 均衡本地网络流量。 默认禁用。 net.inet.carp.suppress_preempt 此只读 OID 显示抑制抢占的状态。 如果一个接口上的连接失去响应, 则抢占会被抑制。 当这个变量的值为 0 时,表示抢占未被抑制。 任何问题都会使 OID 递增。 CARP 设备可以通过 ifconfig 命令来创建。 &prompt.root; ifconfig carp0 create 在真实环境中, 这些接口需要一个称作 VHID 的标识编号。 这个 VHID 或 Virtual Host Identification (虚拟主机标识) 用于在网络上区分主机。 使用 CARP 来改善服务的可用性 (CARP) 如前面提到的那样, CARP 的作用之一是改善服务的可用性。 这个例子中, 将为三台主机提供故障转移服务, 这三台服务器各自有独立的 IP 地址, 并提供完全一样的 web 内容。 三台机器以 DNS 轮询的方式提供服务。 用于故障转移的机器有两个 CARP 接口, 分别配置另外两台服务器的 IP 地址。 当有服务器发生故障时, 这台机器会自动得到故障机的 IP 地址。 这样以来, 用户就完全感觉不到发生了故障。 故障转移的服务器提供的内容和服务, 应与其为之提供热备份的服务器一致。 两台机器的配置, 除了主机名和 VHID 之外应完全一致。 在我们的例子中, 这两台机器的主机名分别是 hosta.example.orghostb.example.org。 首先, 需要将 CARP 配置加入到 rc.conf。 对于 hosta.example.org 而言, rc.conf 文件中应包含下列配置: hostname="hosta.example.org" ifconfig_fxp0="inet 192.168.1.3 netmask 255.255.255.0" cloned_interfaces="carp0" ifconfig_carp0="vhid 1 pass testpass 192.168.1.50/24" hostb.example.org 上, 对应的 rc.conf 配置则是: hostname="hostb.example.org" ifconfig_fxp0="inet 192.168.1.4 netmask 255.255.255.0" cloned_interfaces="carp0" ifconfig_carp0="vhid 2 pass testpass 192.168.1.51/24" 在两台机器上由 ifconfig 选项指定的密码必须是一致的, 这一点非常重要。 carp 设备只会监听和接受来自持有正确密码的机器的公告。 此外, 不同虚拟主机的 VHID 必须不同。 第三台机器, provider.example.org 需要进行配置, 以便在另外两台机器出现问题时接管。 这台机器需要两个 carp 设备, 分别处理两个机器。 对应的 rc.conf 配置类似下面这样: hostname="provider.example.org" ifconfig_fxp0="inet 192.168.1.5 netmask 255.255.255.0" cloned_interfaces="carp0 carp1" ifconfig_carp0="vhid 1 advskew 100 pass testpass 192.168.1.50/24" ifconfig_carp1="vhid 2 advskew 100 pass testpass 192.168.1.51/24" 配置两个 carp 设备, 能够让 provider.example.org 在两台机器中的任何一个停止响应时, 立即接管其 IP 地址。 默认的 &os; 内核 可能 启用了主机间抢占。 如果是这样的话, provider.example.org 可能在正式的内容服务器恢复时不释放 IP 地址。 此时, 管理员必须手工强制 IP 回到原来内容服务器。 具体做法是在 provider.example.org 上使用下面的命令: &prompt.root; ifconfig carp0 down && ifconfig carp0 up 这个操作需要在与出现问题的主机对应的那个 carp 接口上进行。 现在您已经完成了 CARP 的配置, 并可以开始测试了。 测试过程中, 可以随时重启或切断两台机器的网络。 如欲了解更多细节, 请参见 &man.carp.4; 联机手册。
diff --git a/zh_CN.GB2312/books/handbook/basics/chapter.sgml b/zh_CN.GB2312/books/handbook/basics/chapter.sgml index 88bfc4d7ba..dfdfec0f04 100644 --- a/zh_CN.GB2312/books/handbook/basics/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/basics/chapter.sgml @@ -1,2501 +1,2506 @@ Chris Shumway Rewritten by UNIX 基础 概述 下列章节的命令和功能适用于FreeBSD操作系统。 同时这里许多内容和一些 类-&unix; 操作系统相关。 假如您已经熟悉这些内容可跳过不阅读。 假如您是FreeBSD新手, 那您应该认真详细地从头到尾读一遍这些章节。 读取这些内容,您将了解: 怎样在FreeBSD使用 虚拟控制台 在 &unix; 中文件权限如何运作, 以及理解 &os; 中的文件标志。 &os; 默认文件系统的架构。 &os;磁盘架构。 怎样挂接或卸下文件系统。 什么是进程、守护进程、信号。 什么是shell,应当怎样去改变登录进入的默认环境。 怎样使用基本的文本编辑器。 什么是设备,什么是设备节点。 &os; 下,使用的是什么可执行文件格式。 怎样使用 man 手册并取得更多资讯。 虚拟控制台和终端 虚拟控制台 终端 可以用多种不同的方式使用 FreeBSD, 在文本终端输入命令是其中之一。 通过使用这种方式, 您可以容易地使用 FreeBSD 来获得 &unix; 操作系统的灵活而强大的功能。 这一节将介绍 终端控制台, 以及如何在 FreeBSD 中使用它们。 控制台 控制台 假如您没有设置 FreeBSD 在启动期间开启图形登录界面, 那么系统将在引导和启动脚本正确运行完成后,给您一个登录的提示。 您会看到类似这样的界面: Additional ABI support:. Local package initialization:. Additional TCP options:. Fri Sep 20 13:01:06 EEST 2002 FreeBSD/i386 (pc3.example.org) (ttyv0) login: 这些信息可能和您的系统稍微有点不同,但不会有很大差别。 最后两行是我们感兴趣的, 理解这一行: FreeBSD/i386 (pc3.example.org) (ttyv0) 这一行是您刚才启动的系统信息其中一块, 您所看到的是一个FreeBSD控制台, 运行在一个Intel或兼容的x86体系架构上面 现在理解一下i386的含义。 请注意尽管您的 FreeBSD 并非在 Intel 386 CPU 上运行, 但也会显示为 i386。 这不是指您的处理器, 而是指处理器的 体系结构 。 这台计算机的名字 (每台 &unix; 计算机都有自己的名字) 叫 pc3.example.org, 就是现在这个系统控制台—这个 ttyv0 终端的样子。 在最后,最后一行一直保持这样: login: 这里, 您将可以输入用户名 username 并登录到 &os; 系统中。 接下来的一节, 将介绍如何登录系统。 进入FreeBSD FreeBSD是一个多用户多任务的系统, 换句话来说就是一个系统中可以容纳许多不同的用户, 而这些用户都可以同时在这台机器中运行大量的程序。 每一个多用户系统都必须在某方面去区分 user, 在 FreeBSD 里 (以及 类-&unix; 操作系统), 完成这方面工作是有必要的, 因而, 每位使用者在运行程序之前都必须首先 登录, 而每位用户都有与之对应的用户名 (username) 和密码 (password)。 FreeBSD 会在用户进入之前作出询问这两项信息。 启动脚本 当 FreeBSD 引导并运行完启动脚本之后, 启动脚本这些程序在FreeBSD在启动过程中运行。 它们的主要功能为其他每方面的运行作好准备, 和运行您的配置所用到的相关环境。 , 它会给出一个提示, 并要求输入有效的用户名: login: 举个例子更容易理解,我们假设您的用户名叫 john。 在提示符下输入 john 并按 Enter, 此时您应该看到这个提示 password login: john Password: 现在输入 john的密码并按下 Enter。 输入密码时是 不回显的! 不必为此担心, 这样做是出于安全考虑。 假如您输入的密码是正确的, 这时你应该已进入 FreeBSD, 并可以开始尝试可用的命令了。 您应该看见 MOTD 或者出现一个命令提示符 (#$% 字符). 这表明您已成功登录进入FreeBSD。 多个控制台 在一个控制台运行 &unix; 命令虽说很好, 但 FreeBSD 具有一次运行 多个程序的能力。 仅使用一个控制台只会浪费 FreeBSD 同时运行多任务的能力。 而 虚拟控制台 在这方面发挥强大的功能。 FreeBSD 能配置出满足您不同需求的虚拟控制台, 在键盘上您用一组键就能从各个虚拟控制台之间切换。 各个控制台有自己的传输通道, 当您在各个控制台切换时 FreeBSD 会切换到合适的键盘传输通道和显示器传输通道。 FreeBSD 各个控制台之间可利用特殊组键切换并保留原有控制台 关于 FreeBSD 的控制台和键盘设备这些详细资料或使用技巧可在手册里找到: &man.syscons.4;、&man.atkbd.4;、&man.vidcontrol.1; 和 &man.kbdcontrol.1;。 我们不在这里详细介绍, 但是爱好者总会在手册里找到详细的答案。 ,您可这样做: AltF1AltF2, 一直到 AltF8 在FreeBSD里切换到其中一个虚拟控制台。 同样地, 您正在从其中某个控制台切换到另一个控制台的时候, FreeBSD 会保存正在使用和恢复将要使用屏幕传输通道。 这种结果形成一种 错觉, 您拥有许多虚拟屏幕和键盘可以输入很多的命令。 这些程序需要在一个虚拟控制台不能停止运行而又不需要观察它, 它继续运行而您可以切换到其他的虚拟控制台。 <filename>/etc/ttys</filename>文件 FreeBSD 虚拟控制台的默认配置为8个,但并不是硬性设置, 您可以很容易设置虚拟控制台的个数增多或减少。 虚拟控制台的的编号和设置在 /etc/ttys 文件里。 您可以使用 /etc/ttys 文件在 FreeBSD 下配置虚拟控制台。 文件里每一未加注释的行都能设置一个终端或虚拟控制台 (当行里含有 # 这个字符时不能使用) 。 FreeBSD 默认配置是配置出9个虚拟控制台而只能启动8个, 以下这些行是 ttyv 一起启动: # name getty type status comments # ttyv0 "/usr/libexec/getty Pc" cons25 on secure # Virtual terminals ttyv1 "/usr/libexec/getty Pc" cons25 on secure ttyv2 "/usr/libexec/getty Pc" cons25 on secure ttyv3 "/usr/libexec/getty Pc" cons25 on secure ttyv4 "/usr/libexec/getty Pc" cons25 on secure ttyv5 "/usr/libexec/getty Pc" cons25 on secure ttyv6 "/usr/libexec/getty Pc" cons25 on secure ttyv7 "/usr/libexec/getty Pc" cons25 on secure ttyv8 "/usr/X11R6/bin/xdm -nodaemon" xterm off secure 如果要了解这个文件中每一列的详细介绍, 以及虚拟控制台上所能使用的配置, 请参考联机手册 &man.ttys.5;。 单用户模式的控制台 关于 单用户模式 详细介绍在 这里可以找到。 当您运行单用户模式时只能使用一个控制台, 没有多个虚拟控制台可使用。 单用户模式的控制台同也可以在 /etc/ttys 文件设置, 可在这行找到要启动的控制台 # name getty type status comments # # If console is marked "insecure", then init will ask for the root password # when going to single-user mode. console none unknown off secure 这个 console 已经注释掉, 您可编辑这行把 secure 改为 insecure。 这样, 当用单用户进入 FreeBSD 时, 它仍然要求提供 root 用户的密码。 在把这个选项改为 insecure 的时候一定要小心, 如果您忘记了 root用户的密码, 进入单用户会有点麻烦。 尽管仍然能进入单用户模式, 但如果您不熟悉它就会非常令人头疼。 改变控制台的显示模式 FreeBSD 控制台默认的显示模式可以被调整为 1024x768, 1280x1024, 或者任何你的显卡芯片和显示器所支持的其他尺寸。 要使用一个不同的显示模式, 你必须首先重新编译内核并包含以下2个选项: options VESA options SC_PIXEL_MODE 在内核用这2个选项编译完成后,你就可以使用 &man.vidcontrol.1; 工具来测定你的硬件支持何种显示模式了。 以 root 身份在控制台键入以下命令来获得一份所支持的显示模式列表。 &prompt.root; vidcontrol -i mode 这个命令的输出是一份你的硬件所支持的显示模式列表。 你可以在以 root 身份在控制台上键入 &man.vidcontrol.1; 命令来改变显示模式: &prompt.root; vidcontrol MODE_279 如果你对于新的显示模式满意,那么可以把它加入到 /etc/rc.conf 使机器在每次启动的时候都能生效, 我们使用了上一个例子中的模式: allscreens_flags="MODE_279" 权限 UNIX FreeBSD,是 BSD &unix; 的延续, 并基于几个关键的 &unix; 观念。 从一开始就多处提到 FreeBSD 是一个多用户的操作系统, 它能分别处理几个同时工作的用户所分配的毫无关联任务。 并负责为每位用户的硬件设备、 外设、 内存和 CPU 处理时间作出合理安排。 因为系统有能力支持多用户, 在每一方面系统都会作出谁能读、 写和执行的资源权力限制。 这点权限以三个八位元的方式储存着, 一个是表示文件所属者, 一个是表示文件所属群组, 一个是表示其他人。 这些数字以下列方式表示: 权限 文件权限 数值 权限 目录列表 0 不能读,不能写,不能执行 --- 1 不能读,不能写,可执行 --x 2 不能读,可写,不能执行 -w- 3 不能读,可写,可执行 -wx 4 可读,不能写,不能执行 r-- 5 可读,不能写,可执行 r-x 6 可读,可写,不能执行 rw- 7 可读,可写,可执行 rwx ls 目录 使用命令的 (&man.ls.1;) 参数可以显示出文件的所属者、 所属组和其他人等属性。 请看以下的例子: &prompt.user; ls -l total 530 -rw-r--r-- 1 root wheel 512 Sep 5 12:31 myfile -rw-r--r-- 1 root wheel 512 Sep 5 12:31 otherfile -rw-r--r-- 1 root wheel 7680 Sep 5 12:31 email.txt ... 使用 ls -l 在每行的开始出现了: -rw-r--r-- 从左边起的第一个字,告诉我们这个文件是一怎样的文件: 普通文件?目录?特殊设备?socket?或是设备文件? 在这个例子, - 表示一个普通文件。 接下来三个字是 rw- 是文件拥有者的权限。 再接下来的三个字是 r-- 是文件所属群组的权限。 最後三个字是 r-- 是其他人的权限。 以这一个文件为例,他的权限设定是拥有者可以读写这个文件、群组可以读取、 其他使用者也能读取这个文件。 根据上面的表格, 用数字表示这个文件其三部分的权限应该是 644 这样很好,但系统怎样对设备进行权限控制的? 事实上 FreeBSD 将大部份硬件设备当作一个文件看待, 用程序能打开、读取、写入数据就如其他的文件一样。 而设备文件放在 /dev 目录。 目录也视为一种文件,也有读取、写入、执行的权限。 但目录的执行权限意义并不与普通文件相同, 实际上执行权限是进入权限。 当一个目录是被标示可以执行的时, 表示可以进入它, 或者换言之, 利用 cd (改变当前目录) 进入它。 此外, 这也表示有权进入目录的用户, 可以访问其下的已知名字的文件 (当然目录下的文件也受到访问限制)。 详细方面,想读取一个目录的列表就必须设为可读权限, 同时想删除一个已知的文件,就必须把目录下这个文件设为可写 执行权限。 还有更多权限设定, 但是他们大多用在特殊状况下如一个setuid的执行文件和粘贴性目录, 如果想要得知有关文件权限和如何设定的更多资讯,请看手册&man.chmod.1;。 Tom Rhodes Contributed by 权限的符号化表示 权限符号 权限符号,某些时候就是指符号表达式, 使用八进制的字符给目录或文件分配权限。 权限符号的使用语法是 (谁) (作用) (权限)。 看看下列数值的在那些地方所起什么样的作用: 选项 字母 介绍 (谁) u 用户 (谁) g 所属群体 (谁) o 其他人 (谁) a 所有人 (全部) (作用) + 增加权限 (作用) - 减少权限 (作用) = 确定权限 (权限) r 可读 (权限) w 可写 (权限) x 执行 (权限) t 粘贴位 (权限) s 设置 UID 或 GID 这些数值 &man.chmod.1; 以习惯标定的。 举个例子,用以下命令阻止其他人访问 FILE文件: &prompt.user; chmod go= FILE 如果需要对文件一次进行多项变动, 则可用逗号分开, 在下面的例子中, 将去掉 FILE 文件的群体和 全体其他用户 可写权限, 并为所有人增加可执行权限: &prompt.user; chmod go-w,a+x FILE Tom Rhodes Contributed by &os; 文件标志 在前面所介绍的文件权限的基础之上, &os; 还支持使用 文件标志。 这些标志为文件提供了进一步的安全控制机制, 但这些控制并不适用于目录。 这些文件标志提供了针对文件的进一步控制, 帮助确保即使是 root 用户也无法删除或修改文件。 文件标志可以通过使用 &man.chflags.1; 工具来修改, 其用户界面很简单。 例如, 要在文件 file1 上应用系统禁删标志, 应使用下述命令: &prompt.root; chflags sunlink file1 要禁用系统禁删标志, 只需在前述命令中的 标志前加 no。 例如: &prompt.root; chflags nosunlink file1 要显示文件上的标志, 应使用命令 &man.ls.1; 的 参数: &prompt.root; ls -lo file1 输出结果应类似于: -rw-r--r-- 1 trhodes trhodes sunlnk 0 Mar 1 05:54 file1 许多标志只可以由 root 用户来增加, 而另一些, 则可以由文件的所有者来增加。 建议管理员仔细阅读 &man.chflags.1; 和 &man.chflags.2; 联机手册, 以对其加深理解。 Tom Rhodes 原作 setuid、 setgid 和 sticky 权限 除了前面已经讨论过的那些权限之外, 还有三个管理员应该知道的权限配置。 它们是 setuidsetgidsticky 这些配置对于一些 &unix; 操作而言很重要, 因为它们能提供一些一般情况下不会授予普通用户的功能。 为了便于理解, 我们首先介绍真实用户 ID (real user ID) 和生效用户 ID (effective user ID)。 真实用户 ID 是拥有或启动进程的用户 UID。 生效 UID 是进程以其身份运行的用户 ID。 举例来说, &man.passwd.1; 工具通常是以发起修改密码的用户身份启动, 也就是说其进程的真实用户 ID 是那个用户的 ID; 但是, 由于需要修改密码数据库, 它会以 root 用户作为生效用户 ID 的身份运行。 这样, 普通的非特权用户就可以修改口令, 而不是看到 Permission Denied 错误了。 &man.mount.8; 的 nosuid 选项可以令系统在不给出任何错误提示的情况下不执行这些程序。 另一方面, 这个选项并不是万无一失的, 正如 &man.mount.8; 联机手册所提到的那样, 如果系统中安装了绕过 nosuid 的封装程序, 那么这种保护就可以被绕过了。 setuid 权限可以通过在普通权限前面加上一个数字四 (4) 来设置, 如下面的例子所示: &prompt.root; chmod 4755 suidexample.sh 这样一来, suidexample.sh 的权限应该如下面这样: -rwsr-xr-x 1 trhodes trhodes 63 Aug 29 06:36 suidexample.sh 您会注意到, 在原先的属主执行权限的位置变成了 s。 这样, 需要提升特权的可执行文件, 例如 passwd 就可以正常运行了。 可以打开两个终端来观察这一情形。 在其中一个终端里面, 以普通用户身份启动 passwd 进程。 在它等待输入新口令时, 在另一个终端中查看进程表中关于 passwd 命令的信息。 在终端 A 中: Changing local password for trhodes Old Password: 在终端 B 中: &prompt.root; ps aux | grep passwd trhodes 5232 0.0 0.2 3420 1608 0 R+ 2:10AM 0:00.00 grep passwd root 5211 0.0 0.2 3620 1724 2 I+ 2:09AM 0:00.01 passwd 正如前面所说的那样, passwd 是以普通用户的身份启动的, 但其生效 UIDroot 与此对应, setgid 权限的作用, 与 setuid 权限类似, 只是当应用程序配合这一设定运行时, 它会被授予拥有文件的那个组的权限。 如果需要在文件上配置 setgid 权限, 可以在权限数值前面增加数字二 (2) 来运行 chmod 命令, 如下面的例子所示: - &prompt.root; chmod 2755 suidexample.sh + &prompt.root; chmod 2755 sgidexample.sh 可以用与前面类似的方法来检视新设定的生效情况, 在组权限的地方的 s 表示这一配置已经生效: - -rwxr-sr-x 1 trhodes trhodes 44 Aug 31 01:49 suidexample.sh + -rwxr-sr-x 1 trhodes trhodes 44 Aug 31 01:49 sgidexample.sh 在这些例子中, 尽管 shell 脚本也属于可执行文件的一种, 但它们不会以您配置的 EUID 或生效用户 ID 的身份运行。 这是因为 shell 脚本可能无法直接呼叫 &man.setuid.2; 调用。 我们已经讨论了两个特殊权限位 (setuidsetgid 权限位), 它们让用户在使用程序时能够用到更高的权限, 有时这会削弱系统的安全性。 除了这两个之外, 还有第三个特殊权限位: sticky bit, 它能够增强安全性。 当在目录上设置了 sticky bit 之后, 其下的文件就只能由文件的所有者删除了。 这个权限设置能够防止用户删除类似 /tmp 这样的公共目录中不属于他们的文件。 要应用这种权限, 可以在权限设置前面加上数字一 (1)。 例如: &prompt.root; chmod 1777 /tmp 现在, 可以用 ls 命令来查看效果: &prompt.root; ls -al / | grep tmp drwxrwxrwt 10 root wheel 512 Aug 31 01:49 tmp 这里的结尾的 t 表示了 sticky bit 权限。 目录架构 目录层次 理解 FreeBSD 的目录层次结构对于建立对系统整体的理解十分重要的基础。 其中, 最重要的概念是根目录, /。 这个目录是系统引导时挂接的第一个目录, 它包含了用以准备多用户操作所需的操作系统基础组件。 根目录中也包含了用于在启动时转换到多用户模式之前挂接其他文件系统所需的挂接点。 挂接点 (mount point) 是新增的文件系统在接入现有系统时的起点位置 (通常是根目录)。 在 对此进行了详细的阐述。 标准的挂接点包括 /usr/var/tmp/mnt, 以及 /cdrom。 这些目录通常会在 /etc/fstab 文件中提及。 /etc/fstab 是一张包含系统中各个文件系统及挂接点的表。 在 /etc/fstab 中的绝大多数文件系统都会在启动时由 &man.rc.8; 脚本自动挂接, 除非特别指定了 选项。 更多细节请参考 您可以通过 &man.hier.7; 来了解完整的文件系统层次说明。 现在, 让我们先来看一看绝大多数的常见的目录以供参考。 目录 介绍 / 文件系统的根目录。 /bin/ 在单个用户和多用户环境下的基本工具目录。 /boot/ 在操作系统在启动加载期间所用的程序和配置。 /boot/defaults/ 默认每步引导启动的配置内容,请查阅&man.loader.conf.5;。 /dev/ 设备节点,请查阅 &man.intro.4;。 /etc/ 系统启动的配置和脚本。 /etc/defaults/ 系统默认的启动配置和脚本,请参考 &man.rc.8; 。 /etc/mail/ 关系到邮件系统运作的配置, 请参考 &man.sendmail.8;。 /etc/namedb/ named 配置文件,请参考 &man.named.8;。 /etc/periodic/ 每天、每星期和每月周期性地运行的脚本, 请通过 &man.cron.8;查阅 &man.periodic.8;。 /etc/ppp/ ppp配置文件,请查阅&man.ppp.8;。 /mnt/ 由管理员习惯使用挂接点的临时空目录。 /proc/ 运行中的文件系统,请参阅 &man.procfs.5; 和 &man.mount.procfs.8;。 /rescue/ 用于紧急恢复的一组静态联编的程序; 参见 &man.rescue.8;。 /root/ root用户的Home(主)目录。 /sbin/ 在单个用户和多用户环境下的存放系统程序和管理所需的基本实用目录。 /tmp/ 临时文件。 /tmp 目录中的内容, 一般不会在系统重新启动之后保留。 通常会将基于内存的文件系统挂在 /tmp 上。 这一工作可以用一系列 tmpmfs 相关的 &man.rc.conf.5; 变量来自动完成。 (或者, 也可以在 /etc/fstab 增加对应项; 参见 &man.mdmfs.8;)。 /usr/ 存放大多数用户的应用软件。 /usr/bin/ 存放实用命令,程序设计工具,和应用软件。 /usr/include/ 存放标准 C include 文件. /usr/lib/ 存放库文件。 /usr/libdata/ 存放各种实用工具的数据文件。 /usr/libexec/ 存放系统实用或后台程序 (从另外的程序启动执行)。 /usr/local/ 存放本地执行文件, 库文件等等, 同时也是 FreeBSD ports 安装的默认安装目录。 /usr/local/usr 中的目录布局大体相同, 请查阅 &man.hier.7;。 但 man 目录例外, 它们是直接放在 /usr/local 而不是 /usr/local/share 下的, 而 ports 说明文档在 share/doc/port /usr/obj/ 通过联编 /usr/src 得到的目标文件。 /usr/ports 存放 FreeBSD 的 Ports Collection (可选)。 /usr/sbin/ 存放系统后台程序 和 系统工具 (由用户执行)。 /usr/share/ 存放架构独立的文件。 /usr/src/ 存放 BSD 或者本地源码文件。 /usr/X11R6/ 存放 X11R6 可执行文件、 库文件、 配置文件等的目录(可选)。 /var/ 多用途日志、 临时或短期存放的, 以及打印假脱机系统文件。 有时会将基于内存的文件系统挂在 /var 上。 这一工作可以通过在 &man.rc.conf.5; 中设置一系列 varmfs 变量 (或在 /etc/fstab 中加入一行配置; 参见 &man.mdmfs.8;) 来完成。 /var/log/ 存放各种的系统记录文件。 /var/mail/ 存放用户mailbox(一种邮件存放格式)文件。 /var/spool/ 各种打印机和邮件系统spooling(回环)的目录。 /var/tmp/ 临时文件。 这些文件在系统重新启动时通常会保留, 除非 /var 是一个内存中的文件系统。 /var/yp NIS 映射。 磁盘组织 FreeBSD 查找文件的最小单位是文件名。 而文件名区分大小写,这就意味着 readme.txtREADME.TXT 是两个不相同的文件。 FreeBSD 不凭文件扩展名 (.txt) 去识别这个文件是 程序、 文档, 或是其他格式的数据。 各种文件存放在目录里。 一个目录可以为空, 也可以含有多个的文件。一个目录同样可以包含其他的目录, 允许您在一个目录里建立多个不同层次的目录。 这将帮助您轻松地组织您的数据。 文件或目录是由文件名或目录名,加上斜线符号 /, 再根据需要在目录名后面加上其他目录的名称。 如果您有一个名为 foo 的目录, 它包含另一个目录 bar, 后者包括一个叫 readme.txt 的文件, 则全名, 或者说到文件的 路径 就是 foo/bar/readme.txt 在文件系统里目录和文件的作用是存储数据。 每一个文件系统都有且只有一个顶级目录 根目录, 这个根目录则可以容纳其他目录。 您也许在其他的一些操作系统碰到类似这里的情况, 当然也有不同的情况。 举些例子, &ms-dos; 是用 \ 分隔文件名或目录名, 而 &macos; 则使用: FreeBSD在路径方面不使用驱动器名符号或驱动器名称, 在FreeBSD里您不能这样使用: c:/foo/bar/readme.txt 为了代替(驱动器名符号), 一个文件系统会指定 根 文件系统, 根文件系统的根目录是 /。 其他每一个文件系统 挂接在根文件系统下。 无论有多少磁盘在FreeBSD 系统里, 每个磁盘都会以目录的方式加上。 假设您有三个文件系统, 名为 ABC。 每个文件系统有一个根目录, 而各自含有两个其他的目录, 名为 A1, A2 ( B1, B2C1, C2)。 看看 A 这个根文件系统。 假如您用 ls 命令来查看这个目录您会见到两个子目录: A1A2。 这个目录树是这个样子: / | +--- A1 | `--- A2 一个文件系统必须挂到另一个文件系统的某一目录, 所以现在假设把 B 文件系统挂到 A1目录, 那 B 根目录因此代替 了 A1,而显示出 B 目录(的内容): / | +--- A1 | | | +--- B1 | | | `--- B2 | `--- A2 无论B1B2 目录在那里而延伸出来的路径必须为 /A1/B1/A1/B2。 而在 /A1 里原有的文件会临时隐藏。 想这些文件再出现把 B 从 A 挂接释放 所有在B1B2 目录里的文件都可以通过 /A1/B1/A1/B2 访问。而在 /A1 中原有的文件会被临时隐藏,直到 B 从 A 上被卸载 (unmout) 为止。 B 挂接在 A2 那图表的样子就是这样子: / | +--- A1 | `--- A2 | +--- B1 | `--- B2 这个路径分别是 /A2/B1/A2/B2 文件系统能把顶部挂接在另一个文件系统上。 继续这个例子, 把 C 文件系统挂接在 B 文件系统里的 B1 目录, 排列如下: / | +--- A1 | `--- A2 | +--- B1 | | | +--- C1 | | | `--- C2 | `--- B2 或者把 C 文件系统挂接在 A 文件系统里的A1目录: / | +--- A1 | | | +--- C1 | | | `--- C2 | `--- A2 | +--- B1 | `--- B2 假如您熟悉 &ms-dos; 并知道 join 命令, 尽管不相同,其实功能是相似的。 这方面不是普通知识而且涉及到您自己所关心的, 当您安装FreeBSD并在以后添加新磁盘时, 您必须知到该如何新建文件系统和挂接上。 (FreeBSD系统)它有一个主要的根文件系统, 不需要另外新建立, 但当需要手工处理时,这是一个有用的知识。 多个文件系统的益处 不同的文件系统可用不同的 挂接参数。 举些例子, 仔细想一下, 根文件系统能用只读的方式挂接上, 防止不经意删除或编辑到一个危险的文件。 把各用户能写入的文件系统分开, 像/home这样, 由另外的文件系统分别用 nosuid 参数挂接,这个参数防止 suid/guid 在执行这个文件系统中的文件时生效, 从而缓解了一些安全问题。 FreeBSD 能根据一个文件系统使用的情况自动优化 这个文件系统上的文件布局。 所以对一个存储了大量小文件并会被频繁写入文件系统的优化与一个存储了少量大文件的优化是不同的。 而在一个大的单一文件系统上则无法体现这样的优化。 FreeBSD 的文件系统能够在断电时尽可能避免损失。 然而, 在关键点时的电源失效仍然可能会破坏文件系统的结构。 将您的文件系统分成多个有助于分散风险, 并方便备份和恢复。 单一文件系统的益处 文件系统是固定大小的。 当安装FreeBSD时新建一个文件系统并设定一个大小, 您会在稍后发觉到必须去建一个大的分区。 如果配置不当, 则需要备份、 重新创建文件系统, 然后再恢复数据。 FreeBSD 提供了 &man.growfs.8; 命令。 这使得能够实时地调整文件系统的大小, 因而不再受其限制。 文件系统是和分区一一对应的。 这里的分区和常用的术语分区 (例如, &ms-dos; 分区) 的意思并不一样, 这是由于 &os; 的 &unix; 传统造成的。 每一个分区使用一个从 ah 的字母来表示。 每个分区只能包含一个文件系统, 这意味着文件系统通常可以由它们在文件系统目录结构中的挂接点, 或对应的分区字母来表示。 FreeBSD 的 交换分区 也需要使用磁盘空间。 交换分区是给 FreeBSD 作 虚拟内存 使用的, 这样能令您的计算机有更多的内存可使用, 当FreeBSD在运行而内存不够的时候, 它会把其他一些可转移的数据转移到交换分区, 空出内存的位置以供使用。 某些 partitions 的用途是确定的。 分区 约定 a 通常指定为根文件系统 b 通常指定为交换分区 c 通常它和所在的 slice 大小相同。 c 分区上工作时必定会影响到事整个 slice (举个例子,坏块扫描器)。 您通常不愿意在这个partition建立文件系统。 d 分区 d 曾经有特殊的含义, 不过这种意义在现时的系统上已不再适用, 因此 d 可以和任何其它普通的分区一样使用了。 每一个包含了文件系统的分区被保存在 FreeBSD 称为 slice 的部分上。 Slice 是一个 FreeBSD 术语, 通常被叫做分区, 再次强调, 这是由于 FreeBSD 的 &unix; 背景。 Slices 有其编号, 从1到4。 slices partitions 专用 (dangerously dedicated) Slice 编号在设备名后面, 并有一个 s 前缀, 从 1 开始。 因此 da0s1 是第一个 SCSI 驱动器的第一个 slice。 每个磁盘上只能有四个物理的 slices, 但您可以在物理 slice 中使用适当的类型来创建逻辑 slice。 这些扩展 slice 编号从 5 开始, 因此 ad0s5 是第一个 IDE 磁盘中的第一个 扩展 slice。 文件系统所使用的设备应该占满 slice。 Slices, 专用指定 物理驱动器, 和其他驱动器都包含 partitions, 那几个的 partitions 都是用字母从 ah 来标定的, 而这些字母都在驱动器名字之后,所以 da0a 是指首个da设备的 a partition, 而那个就是 专项指定ad1s3e 是指IDE磁盘上第三个slice的第五个partition。 最终,每个磁盘都被系统识别。 一个磁盘名字是用磁盘类型代码和编号来标识的, 它不像slices,磁盘的编号是由0开始的。 对应代码请看这里所列出的 当在 FreeBSD 中指定 partition 名字时, 必须同时包含这个分区的 slice 和磁盘的名字; 类似地, 在指定 slice 时, 也应该给出包含该 slice 的磁盘名字。 可这样列出: 磁盘名称,s,slice 编号,和partition标定字母。 例子请看 这里显示了一个磁盘的布局,有更清楚的帮助。 在安装FreeBSD时,您首先要配置好磁盘slices, 然后在FreeBSD使用的slice上建立partitions。 并在每个partition上建立一个文件系统(或交换分区), 和指定文件系统的挂接位置。 磁盘设备的代码 代码 说明 ad ATAPI (IDE) 磁盘 da SCSI 直接存取磁盘 acd ATAPI (IDE) 光驱 cd SCSI 光驱 fd 软驱
样例磁盘, Slice, 和 Partition 它们的命名 命名 说明 ad0s1a 在首个IDE磁盘(ad0)上的 第一个slice (s1)里的 第一个partition (a)。 da1s2e 在第二个SCSI磁盘(da1)上的 第二个slice(s2)里的 第五个partition(e)。 一个磁盘的布局 从在系统里的首个IDE磁盘图表可以显示出FreeBSD的见解。 假设磁盘大小为4 GB,它里面包含了两个2 GB 大小的slices (但在&ms-dos;叫partitions)。 首个slice是一个&ms-dos;磁盘叫C:, 而第二个slice是FreeBSD配置好的slice。 FreeBSD配置好的slice有三个partitions和另一个交换分区。 这三个partitions各自控制一个文件系统。 partitiona 用于根文件系统, partitione 用于 /var 目录层, partitionf 用于 /usr 目录层。 .-----------------. --. | | | | DOS / Windows | | : : > First slice, ad0s1 : : | | | | :=================: ==: --. | | | Partition a, mounted as / | | | > referred to as ad0s2a | | | | | :-----------------: ==: | | | | Partition b, used as swap | | | > referred to as ad0s2b | | | | | :-----------------: ==: | Partition c, no | | | Partition e, used as /var > file system, all | | > referred to as ad0s2e | of FreeBSD slice, | | | | ad0s2c :-----------------: ==: | | | | | : : | Partition f, used as /usr | : : > referred to as ad0s2f | : : | | | | | | | | --' | `-----------------' --'
文件系统的挂接和卸下 这种文件系统就像一棵树那样用/确立根部, 是比较理想的文件系统。 而/dev/usr 和其他目录就是根目录的分枝, 另外这些目录可以再分枝,例如/usr/local 根文件系统 应该考虑给某些目录一些空间从而分散文件系统。 /var 之下包含目录 log/,目录spool/, 和不同类型的临时文件,很可能把它塞满。 把什么都塞进根文件系统不是一个好主意, 好的做法是应该把 /var/分离出去。 另一个要考虑的是,给物理设备或虚拟磁盘这些自带空间的文件系统确定目录结构树。 例如 网络文件系统 或光驱的挂接。 <filename>fstab</filename> 文件 文件系统 使用fstab的挂接 引导过程 期间, 自动挂上/etc/fstab所列出的文件系统。 (除非他们注明为 选项)。 /etc/fstab 文件包含的各行的列表格式如下: device /mount-point fstype options dumpfreq passno device 设备名称(设备必须存在), 说明在 . mount-point 目录 (目录必须存在), 用在那个挂接上的文件系统上。 fstype 文件系统类型,请通过&man.mount.8;查阅。 默认的FreeBSD文件系统类型是ufs options 设为可读写文件系统的选项, 或设为只读文件系统的选项, 或其他一些选项,可随意选一个。 一个常用的选项 用在不需在引导过程期间挂接的文件系统。 其他的选项在 &man.mount.8; 手册里列出。 dumpfreq &man.dump.8; 使用这项去决定那个文件系统必须移贮。 假如缺少这项,默认的数值为0。 passno 这一项决定文件系统的检查顺序, 文件系统想跳过检查应将passno设为0。 根文件系统(那个是在每方面开始之前必须检查的) 应该将它的 passno 设为1, 其他文件系统的 passno 必须把数值设到大于1。假如多个文件系统的passno的值相同, 那么 &man.fsck.8; 在允许的情况下将尝试并行地去检查文件系统。 请参阅 &man.fstab.5; 联机手册, 以获得关于 /etc/fstab 文件格式, 以及其中所包含的选项的进一步信息。 <command>mount</command> 命令 文件系统 挂接 这个 &man.mount.8; 命令是挂接文件系统的基本运用。 使用最多的基本格式: &prompt.root; mount device mountpoint 它的选项非常多,而&man.mount.8; 手册同样提及, 但常用的都在这里: 挂接的各种选项 挂接/etc/fstab里所有列出的文件系统。 除非标记为 noauto 或作了排除在外的 类型标记,或者在这之前已挂上。 除了实际上系统调用以外,可以完成任何事情,这个选项是和 参数一起连在一块使用,可以决定&man.mount.8;所做的事情。 强制去挂接一个未知的文件系统(会有危险), 或当把一个文件系统挂接状态由可读写降为只读时,强制撤消可写通道。 以只读方式挂接文件系统。 这和在指定了 选项配合 (对于 &os; 5.2 之前的版本来说, 则是 ) 参数的效果是一样的。 fstype 根据给出的文件系统类型挂接文件系统, 假如给于选项,仅挂接这个类型的文件系统。 ufs 是默认的文件系统类型。 在文件系统上修改挂接选项。 版本模式。 以可读写方式挂接文件系统。 The 选项采用一个逗号分开以下多个选项: noexec 不允许文件系统上的二进制程序执行。这也是一个有用的安全选项。 nosuid 不允许文件系统上的 setuid 或 setgid 标记生效。这也是一个有用的安全选项。 <command>umount</command> 命令 文件系统 卸下 &man.umount.8; 命令同样采用一个参数、一个挂接点、一个设备名。 或采用选项,又或采用选项。 所有格式都可采用 去强行卸下, 或采用 用那适当的版本。 但警告,采用 并不是一个好主意, 强行卸下文件系统可能损坏计算机或破坏文件系统上的数据。 会卸下所有已挂接的文件系, 可能通过后面列出的文件系统进行修改, 但无论如何,都不会尝试去卸下根文件系统。 进程 FreeBSD 是一个多任务操作系统。 这就意味着好像一次可以运行一个以上的程序。 每个占用一定时间运行的程序就叫 进程 (process)。 你运行的每一个命令会至少启动一个新进程,还有很多一直运行着的系统进程, 用以维持系统的正常运作。 每个进程用来标识的一个编号就叫 进程 ID, 或叫 PID。 而且,就像文件那样,每个进程也有所属用户和所属群体。 所属用户和所属群体使用在这方面:确定这个进程可以打开那些文件和那些设备, 从而在初期使用文件的权限。 多数的进程都有一个父进程, 而进程是依靠父进程来启动的。 例如,假如您把命令输入到shell里那shell是一个进程,而您运行的各个命令同样是进程, 那么,shell就是您各个运行进程的父进程。 而这方面有一个例外的进程就叫&man.init.8;。 init始终是首个进程,,所以他的PID始终是1, 而init在FreeBSD起动时由内核自动启动。 在系统上,有两个命令对进程观察非常有用:&man.ps.1; 和 &man.top.1;。 这个ps命令作用是观察当前运行进程的状态, 显示他们的PID,使用了多少内存,它们启动的命令行。 而top命令则是显示所有运行进程,并在以秒计的短时内更新数据。 您能交互式的观察您计算机的工作。 默认情况下, ps仅显示出您自己所运行的命令。 例如: &prompt.user; ps PID TT STAT TIME COMMAND 298 p0 Ss 0:01.10 tcsh 7078 p0 S 2:40.88 xemacs mdoc.xsl (xemacs-21.1.14) 37393 p0 I 0:03.11 xemacs freebsd.dsl (xemacs-21.1.14) 48630 p0 S 2:50.89 /usr/local/lib/netscape-linux/navigator-linux-4.77.bi 48730 p0 IW 0:00.00 (dns helper) (navigator-linux-) 72210 p0 R+ 0:00.00 ps 390 p1 Is 0:01.14 tcsh 7059 p2 Is+ 1:36.18 /usr/local/bin/mutt -y 6688 p3 IWs 0:00.00 tcsh 10735 p4 IWs 0:00.00 tcsh 20256 p5 IWs 0:00.00 tcsh 262 v0 IWs 0:00.00 -tcsh (tcsh) 270 v0 IW+ 0:00.00 /bin/sh /usr/X11R6/bin/startx -- -bpp 16 280 v0 IW+ 0:00.00 xinit /home/nik/.xinitrc -- -bpp 16 284 v0 IW 0:00.00 /bin/sh /home/nik/.xinitrc 285 v0 S 0:38.45 /usr/X11R6/bin/sawfish 在这个例子里您可看到,从 &man.ps.1; 输出的每一列是有规律的。 PID 就是进程ID,这个较早前已讨论过了。 PID号的分配由 1一直上升直到99999, 当您运行到超过限制时,这些编号会回转分配 (仍在使用中的 PID 不会分配给其他进程)。 TT这一列显示了程序运行所在的终端, 目前可以安全地忽略。 STAT 显示程序的状态,也可以安全地被忽略。 TIME是程序在CPU处理时间—运行的时间量, 并不是指您程序启动到现在的所用的时间。 许多程序碰巧遇到某方面在他们之前要花费大量CPU处理时间时,他们就必须等候。 最后, COMMAND 是运行程序时使所用的命令行。 &man.ps.1;支持使用各种选项去改变显示出来的内容, 最有用的一个就是auxww选项显示出所有运行进程的内容, 而不仅仅是您的进程。 选项显示出进程所归属的用户名字以及内存使用, 选项显示出后台进程。 而 选项表示为 &man.ps.1; 把每个进程的整个命令行全部显示完, 而不是由于命令行过长就把它从屏幕上截去。 下面和从&man.top.1;输出是类似的,一个示例式对话就象这样子: &prompt.user; top last pid: 72257; load averages: 0.13, 0.09, 0.03 up 0+13:38:33 22:39:10 47 processes: 1 running, 46 sleeping CPU states: 12.6% user, 0.0% nice, 7.8% system, 0.0% interrupt, 79.7% idle Mem: 36M Active, 5256K Inact, 13M Wired, 6312K Cache, 15M Buf, 408K Free Swap: 256M Total, 38M Used, 217M Free, 15% Inuse PID USERNAME PRI NICE SIZE RES STATE TIME WCPU CPU COMMAND 72257 nik 28 0 1960K 1044K RUN 0:00 14.86% 1.42% top 7078 nik 2 0 15280K 10960K select 2:54 0.88% 0.88% xemacs-21.1.14 281 nik 2 0 18636K 7112K select 5:36 0.73% 0.73% XF86_SVGA 296 nik 2 0 3240K 1644K select 0:12 0.05% 0.05% xterm 48630 nik 2 0 29816K 9148K select 3:18 0.00% 0.00% navigator-linu 175 root 2 0 924K 252K select 1:41 0.00% 0.00% syslogd 7059 nik 2 0 7260K 4644K poll 1:38 0.00% 0.00% mutt ... 这个输出分成两部份。 前面部份(起始前五行) 显示了:运行于最后进程的PID、 系统负载均衡 (那个是指系统繁忙时的调节方式)、 系统正常运行时间 ( 指从启动算起所用的时间) 和当前时间。 前面部份另外的图表 涉及:多少进程在运行(这个情况是47), 多少内存和多少交换分区在使用, 和在不同CPU状态里系统消耗多少时间。 在那下面一连串的纵列和从&man.ps.1;输出的的内存是相似的。 如以前&man.ps.1;一样,您能见到:PID、用户名、CPU处理时间合计、运行的命令。 &man.top.1;默认是显示您的进程所用内存空间的合计。 内存空间这里分成两列,一列为总体大小,另一列是必须请求驻留大小是多少内存—总体大小。 而驻留大小实际上是瞬间使用的多少。 在以上那个例子,您会看到那&netscape;总计需要30 MB内存, 但实际只用了9 MB。 &man.top.1; 每两秒自动刷新一次,您可以用改变刷新的秒数。 守护进程,信号和杀死进程 当您运行一个编辑器时它是很容易控制的,告诉它去加载文件它就加载。 您之所以能这样做,是因为编辑器提供这样便利去这样做,和因为有编辑器去附上的终端。 一些程序在运行中不需要连续的用户输入,一有机会就从终端里分离到后台去。 例如,一个web系统整天都在作web请求的响应,他不需要您输入任何东西就能完成, 这个类别的另一个例子就是把email的传送。 我们把那些程序叫 守护进程。 守护神是希腊神话中的一些人物,非正非邪,他们是些守护小精灵, 大体上为人类作出贡献。 许多类似web服务或mail服务的系统对于今天仍有用途, 这就是为什么在那么长的时间里,BSD的吉祥物保持为一双鞋加一把钢叉的守护神模样。 守护进程的程序命名通常在最后加一个 dBIND 是伯克利互联网域名服务 (而实际执行的程序名称则是 named), Apache web系统的程序就叫 httpd, 在行式打印机上的打印守护进程就是 lpd。 这只是一种惯例,不是标准或硬性规定。 例如,为Sendmail而应用的主要mail守护进程就叫sendmail, 却不叫maild,这和您推测的一样。 有时可能会需要与守护进程进行通讯。 而 信号 则是其中的一种通讯机制。 可以发送信号给守护进程 (或相关的另一些进程) 来与它进行通信, 不同的信号都有自己的数字编号—其中一些有特殊的含义, 其它的则可以被应用程序自己进行解释, 而一般来说, 应用程序的文档会告诉哪些信号会被如何处理。 您只能给所属于您的进程发信号,假如您给其他人的进程发信号, 进程就会用&man.kill.1; 或 &man.kill.2;权限进行拒绝。 当然,root 用户会例外,它能把各种信号发送给每个进程。 在某些情况下,FreeBSD也会向应用软件发送信号。 假如一个应用软件含有恶意写入并试图去访问内存,那是不可想象的,FreeBSD会向那个进程发送 段式违规 信号 (SIGSEGV)。 假如一个应用软件使用&man.alarm.3;系统去进行周期性调用闹钟功能,每当达到时间时, FreeBSD会向应用软件发送闹钟信号(SIGALRM)。 有两个信号可以停止进程:SIGTERMSIGKILLSIGTERM比较友好,进程能捕捉这个信号, 根据您的需要来关闭程序。在关闭程序之前,您可以结束打开的记录文件和完成正在做的任务。 在某些情况下, 假如进程正在进行作业而且不能中断,那么进程可以忽略这个 SIGTERM信号。 对于SIGKILL信号,进程是不能忽略的。 这是一个 '我不管您在做什么,立刻停止'的信号。 假如您发送SIGKILL信号给进程, FreeBSD就将进程停止在那里。 有点不正确—少数的东西是不能中断的。 例如, 假如进程试图读取网络上另一计算机上的文件, 而那个的计算机会因为某些原因拿走了这个文件, 那这个进程从上述情况来看是 不能中断。 最终这个进程会超时,典型的两分钟。一出现超时进程将被杀死。 . 您可能会去使用 SIGHUPSIGUSR1SIGUSR2信号。 这都是些通用的信号,各种应用程序都可以应用 在各方面的信号发送。 假如您改变了web系统的配置文件—并想web系统去重读它的配置, 您可以停止然后再启动httpd。但这样做web系统会导致一个短暂 的中断周期,那样是不受欢迎的。几乎所有的守护进程在编写时,都会指定对SIGHUP 信号进行响应从而重读配置文件。 所以, 最好的方法, 就不是杀死并重启 httpd, 而是发一个 SIGHUP 信号给它。 因为在这方面没有一个标准,不同的守护进程有不同的用法,所以不了解时应读一下守护进程的文档。 发送信号可用&man.kill.1; 命令, 请参考&man.kill.1;所列出的例子。 发送一个信号给进程 这个例子显示了怎样去发一个信号给&man.inetd.8;。 inetd配置文件是/etc/inetd.conf, 如果想inetd 去重读文件系统的话,可以给它发一个SIGHUP 信号。 寻找您要发送信号的进程ID,可以用&man.ps.1; 加 &man.grep.1;来完成。 &man.grep.1;命令被用在搜索输出方面,搜索您指定的字符串。 这命令是由普通用户来执行的,而&man.inetd.8;是root用户运行的, 所以必须给&man.ps.1;带上选项。 &prompt.user; ps -ax | grep inetd 198 ?? IWs 0:00.00 inetd -wW 得出 &man.inetd.8; PID号是198。 有时 grep inetd 命令也出现在输出中, 这是因为在这方面 &man.ps.1; 也是寻找列表中运行进程。 使用 &man.kill.1; 去发送信号。 因为 &man.inetd.8; 是由 root启动的, 您必须使用 &man.su.1; 去 变为 root 用户。 &prompt.user; su Password: &prompt.root; /bin/kill -s HUP 198 和大多数 &unix; 命令一样, &man.kill.1; 如果完成了任务, 就不会给出任何消息。 假如您发送信号给一个不属于您的进程, 您会看到 kill: PID: Operation not permitted. 假如输错了PID号,把信号发送到其他进程,那是坏事。 或者您侥幸,把信号发送到不存在的进程, 您会看见 kill: PID: No such process. 为什么使用 <command>/bin/kill</command>? 许多shell提供了内建 kill 命令, 这样, shell就能直接发送信号,而不是运行 /bin/kill。 这点非常有用, 但不同shell有不同的语法来指定发送信号的名字, 与其试图把它们学完倒不如简单地直接使用 /bin/kill ... 发送其他的信号也很相似, 只要在命令行替换 TERMKILL 就行了。 在系统上随意杀死进程是个坏主意,特别是&man.init.8;, 它的进程ID是1,它非常特殊。可以运行 /bin/kill -s KILL 1 命令来让系统迅速关机。 当您按下 Return (回车)键之前, 一定要 详细检查您运行 &man.kill.1; 时所指定的参数。 Shells shells 命令行 在FreeBSD里,每日有一大堆工作是在命令行的界面完成的,那就叫做shell。 一个shell的主要功能就是从输入取得命令然后去执行他。 许多的shell同样能帮我们完成内建的每日功能,例如:文件管理、文件寻找、命令行编辑、 宏指令和环境变量。FreeBSD内含了一些shell,例如:sh、Bourne Shell、 tcsh和改良过的C-shell。 另外也有些shell也可在FreeBSD的Ports得到,例如:zshbash 您想使用哪一种shell取决于您的喜好, 假如您是C程序设计师,您可能选择一个C-like shell例如tcsh。 假如您是从Linux过来的或是一个命令行的新手,您可能会试一下bash。 这一点告诉我们每一个shell都有各自的特性,可能适用于您的工作环境,也可能不适用于您的工作环境。 每个shell都有一个共通点就是文件名补全。 输入命令或文件名的前几个字,然后按Tab键,就能靠shell的自动补全功能得出 命令或文件名。这里有一个例子,假设您有两个文件叫 foobarfoo.bar,而您想删除 foo.bar, 可这样在键盘上输入 rm fo[Tab].[Tab] 那么shell就会输出 rm foo[BEEP].bar 这个[BEEP] 是这控制台铃声, 那个是告诉我们它不能完成文件名补全,因为有多个文件名符合。 foobarfoo.bar 都是以 fo开头, 它只可以补全到 foo。 输入 .并再按一次 Tab,shell才把其余的文件名全部显示出来。 环境变量 另一个特点就是shell利用环境变量运行。环境变量是贮存在shell环境空间上相对应的键和可变值, 这个空间能够补程序从shell里读出,而且包含了许多程序的配置。 这个一个常用环境变量列和其含义的列表: environment variables (环境变量) 变量 说明 USER 当前登录进入的用户名。 PATH 搜索程序路径,以两点的冒号分隔开。 DISPLAY 假如有这个变量的话,就是X11显示器的网络名称。 SHELL 当前所用的shell。 TERM 用户终端的名字,通常用在确定终端的能力。 TERMCAP 各种终端功能所用终端分离编码的基本数据项目。 OSTYPE 操作系统类型,默认是FreeBSD。 MACHTYPE 是指系统上运行的CPU体系结构。 EDITOR 用户首选的文本编辑器。 PAGER 用户首选的文本页面调度程序 。 MANPATH 搜索联机手册路径,以两点的冒号分隔开。 Bourne shells 不同的shell设置环境变量也不相同。举个例子, 在如tcshcsh这样的C-Style shell, 您必须使用setenv去设置环境变量。 而在如shbash这样的Bourne shell, 您必须使用export去设置当前环境变量。 再举个例子,要去设置或改变EDITOR环境变量, 在cshtcsh下将EDITOR设为 /usr/local/bin/emacs: &prompt.user; setenv EDITOR /usr/local/bin/emacs 而在Bourne shell下,则是: &prompt.user; export EDITOR="/usr/local/bin/emacs" 您也可以在命令行上加一个$字符在变量之前从而取得环境变量。 举个例子,用echo $TERM 就会显示出$TERM的设定值, 其实就是shell取得$TERM并传给echo来显示的。 shell里有许多特别的字符代表着特别的资料,我们把叫做meta-characters。 最常用的就是*字符,它可代表文件名的任何字符。 这些特别字符应用到文件名全域方面。假如,输入 echo *和输入 ls的效果是相同的,其实就是 shell 取得了全部符合 *的文件名,并传给 echo 在命令行下显示出来。 为了防止shell去分析这些特别字符, 我们可在它之前加一个 \字符去说明它只是普通字符。 echo $TERM就会显示出您的终端情况, 而 echo \$TERM 就会显示出 $TERM 这几个字。 改变您用的Shell 改变您的Shell的最简单方法是使用 chsh 命令。 执行 chsh 将根据您设定的EDITOR 环境变量进入到那个编辑器,假如没有设定,就会进入vi编辑器。 请改变Shell:这行对应值。 您可使用chsh选项, 这样就能设置您的shell却又不用编辑器。假如您想把shell改为bash 可用下面的技巧。 &prompt.user; chsh -s /usr/local/bin/bash 您使用的shells必须/etc/shells 文件里列出。 假如您从 ports里装一个shell, 那就不用做这步了。 假如您手工装一个shell,那就要手工添加进去。 举个例了子,假如您手工把 bash装到 /usr/local/bin里,您还要进行这一步: &prompt.root; echo "/usr/local/bin/bash" >> /etc/shells 然后运行chsh 文本编辑器 文本编辑器 编辑器 FreeBSD 的很多配置都可以通过编辑文本文件来完成。 因此, 最好能熟悉某种文本编辑器。 FreeBSD 基本系统中提供了一些, 您也可以从 Ports Collection 安装其它编辑器。 ee editors ee 最容易学的而又简单的编辑器是 ee编辑器, 是个标准的简易编辑器。 要启动 ee,首先就要在命令行输入 ee filenamefilename 是一个要编辑的文件名。 例如,要编辑 /etc/rc.conf就要输入 ee /etc/rc.conf,在 ee的控制内, 编辑器所有功能的操作方法都显示在最上方。 这个^ 字符代表 键盘上的Ctrl 键, 所以^e 就是 Ctrle组合键。 假如想离开ee, 按Esc键,就可选择离开编辑器。 当您修改了内容的时候,编辑器会提示您保存。 vi 编辑器 vi emacs 编辑器 emacs FreeBSD本身也带许可多有强大功能的文本编辑器, 例如 vi。还有其他在FreeBSD Ports里几种, 像 emacsvim。 这些编辑器有着强大的功能,但同时学习起来比较复杂。 不管怎样,假如您从事文字编辑方面的工作, 学习如vimemacs 这些有强大功能的编辑器用法, 在长时间工作里会帮您节省不少的时间。 + + 很多需要修改文件或打字输入的应用程序都会自动打开一个文本编辑器。 + 更改默认使用的编辑器, 请设置 EDITOR + 环境变量。 参阅 shells + 以获取更多详细信息。 设备和设备节点 在一个系统里,硬件描述通常用法就是一个设备对应一个术语,包括磁盘、打印机、显卡和键盘。 当 FreeBSD 启动过程中,大多数的设备都能探测到并显示出来, 您也可以查阅/var/run/dmesg.boot, 引导时所有信息都在里面。 例如, acd0 就是 首个 IDE 光盘设备, 而 kbd0 则代表键盘。 在&unix;操作系统里,大多数设备存在的特殊访问文件就是叫做设备节点, 他们都定位在/dev目录里。 建立设备节点 当在系统中添加新设备或将附加设备的支持编译进内核之后, 都必须为其建立设备节点。 <literal>DEVFS</literal> (DEVice 文件系统) 这个设备文件系统, 或叫 DEVFS, 为内核的设备命名在整体文件系统命名里提供通道, 并不是建立或更改设备节点, DEVFS只是为您的特别文件系统进行维护。 请参见 &man.devfs.5; 联机手册以了解更多细节。 二进制文件格式 要理解为什么 &os; 使用 &man.elf.5; 格式, 您必须首先了解一些 &unix; 系统中的 三种 主要 可执行文件格式的有关知识: &man.a.out.5; 是最古老和经典的 &unix; 目标文件格式, 这种格式在其文件的开始处有一个短小而又紧凑的首部, 该首部带有一个魔幻数字,用来标识具体的格式(更多详情参见&man.a.out.5;)。 这种格式包含3个要装载入内存的段:.text, .data, 和 .bss,以及 一个符号表和一个字符串表。 COFF SVR3目标文件格式。其文件头现在包括一个区段表(section table), 因此除了.text,.data,和.bss区段以外,您还可以包含其它的区段。 &man.elf.5; COFF 的后继, 其特点是可以有多个区段, 并可以使用32位或64位的值。 它有一个主要的缺点: ELF 在其设计时假设每个系统体系结构只有一种 ABI。 这种假设事实上相当错误, 甚至在商业化的SYSV世界中都是错误的 (它们至少有三种ABI: SVR4, Solaris, SCO)。 FreeBSD试图在某种程度上解决这个问题,它提供一个工具,可以 对一个已知的ELF可执行文件 标识它所遵从的ABI的信息。 更多这方面的知识可以参见手册页&man.brandelf.1; FreeBSD从经典阵营中来,因此使用了&man.a.out.5;格式, 众多BSD版本的发行(直到3.X分支的开始)也证明了这种格式的有效性。 虽然在那以前的某段时间,在FreeBSD系统上创建和运行ELF格式 的二进制可执行文件(和内核)也是可能的,但FreeBSD一开始并不积极进步 到使用ELF作为其缺省的格式。为什么?噢,当Linux阵营完成了 转换到ELF格式的痛苦历程后,却发现并不足以由此而放弃 a.out可执行文件格式,因为正是由于它们不灵活的, 基于跳转表的共享库机制,使得销售商和开发者们构建共享库非常困难。 直到已有的ELF工具提供了一种解决共享库问题的办法, 并被普遍认为是前进方向以后,迁徙的代价在FreeBSD界才被接受, 并由此完成了迁徙。FreeBSD的共享库机制其基础更类似于Sun &sunos;的共享库机制, 并且正因为此,其易用性很好。 那么,为什么会有这么多不同的格式呢? 回溯到蒙昧和黑暗的过去,那时只有简单的硬件。这种简单的硬件支撑了一个简单 和小型的系统。在这样的简单系统上(PDP-11)a.out格式 足以胜任表达二进制文件的任务。当人们将&unix;从这种简单的系统中移植出来的时候, a.out格式被保留了下来,因为对于早期将&unix移植到 Motorola 68k,VAXen等系统来说,它还是足够可用的。 然后,一些聪明的硬件工程师认为,如果可以让软件完成一些简单的聪明操作, 那么他们就可以在硬件设计中减少若干门电路,并可以让CPU核心运行得更快。 当a.out格式用于这种新型的硬件系统时(现在我们叫它 RISC),显得并不合适。因此,人们设计了许多新的格式 以便在这样的硬件系统上能获得比简单的a.out格式更优越 的性能。诸如COFFECOFF,还有其它 一些晦涩难懂的格式正是在这个阶段被发明出来的,人们也研究了这些格式的局限性, 慢慢地最终落实到ELF格式。 同时,程序的大小变得越来越大,磁盘空间(以及物理内存)相对来说却仍然较小, 因此共享库的概念便产生了。VM系统也变得越来越复杂了。当所有这些进步都建立在 a.out格式的基础上的时候,它的可用性随着每个新特性 的产生就受到了严重考验。并且,人们还希望可以在运行时动态装载某些东西,或者 在初始化代码运行以后可以丢弃部分程序代码,以便节约主存储器和交换区。编程语言 也变得越来越复杂,人们希望可以在main()函数执行之前自动执行某些代码。为了实现 所有这些功能,人们对a.out格式作了很多改动(hack), 他们在某个阶段里基本也是可行的。随着时间的推移,a.out格式 不得不增加大量的代码和复杂度来满足这些需求。虽然ELF格式 解决了许多这样的问题,但是从一个可用的系统迁移到另一个系统却是痛苦的。因此 直到继续保留a.out格式的代价比迁移到ELF格式 的代价还大的时候,人们才会最终转换到ELF格式。 然而,随着时间的推移,FreeBSD系统本身的编译工具(特别是汇编器和装载器) 赖以派生的编译工具,其发展却形成了两个平行的分支。FreeBSD这个分支增加了共享库, 并修改了一些错误。而原先编写了这些工具的GNU人则重写了这些工具,并对交叉编译提供了 更简化的支持,还随意插入了不同格式的支持,等等。虽然很多人希望创建针对FreeBSD的 交叉编译器,但他们却并未如愿以偿,因为FreeBSD的asld的源代码更为老旧,所以无法完成这个任务。 新的GNU工具链(binutils)则确实支持交叉编译,ELF 格式,共享库,C++扩展,等等。并且,由于很多供应商都发布ELF格式的 二进制文件,因而让FreeBSD能够运行它们将是一个很好的事情。 ELF格式比a.out格式开销要大些,同时也 允许基础系统有更好的扩展性。ELF格式的有关工具有着更好的维护, 并且提供交叉编译支持,这对许多人来说是很重要的。ELF格式可能会稍微 慢一些,但很难测量出来。另外,在这两者之间,有许多细节也是不同的,比如它们映射页面的方式, 处理初始化代码的方式,等等。所有这些都不太重要,但这也确实是不同之处。在将来的适当时候, GENERIC内核将不再支持a.out格式,并且, 当不再需要运行遗留的a.out格式程序时,内核也将不再提供对其的支持。 取得更多的资讯 联机手册 联机手册 最详细的使用说明文档莫过于 FreeBSD 里的联机手册了。 几乎每一个程序都会附上一份简短说明, 以介绍这个程序的的基本功能以及参数的用法。 我们能通过 man 命令来阅读这些说明, 而使用 man 命令却是简单的事情: &prompt.user; man command command 就是您要了解的命令命称。 举个例子,想了解 ls 命令就输入: &prompt.user; man ls 这些在线手册分下列章节: 用户命令。 系统调用以及错误代码。 C 库文件里的函数说明。 设备驱动程序。 文件格式。 游戏以及其他娱乐。 各种资讯。 系统维护以及命令。 内核开发情况。 在某些情况下,同样的主题也会出现在在线手册的不同章节。 举个例子,系统里有chmod这个用户命令,而又有个 chmod() 系统调用。 在这种情形下,您应当向 man 命令指定需要的内容: &prompt.user; man 1 chmod 这样就会显示出手册里的用户 chmod 命令。 传统上,我们在写入文档时把特定详细参考内容在在线手册括号里注明。 所以 &man.chmod.1; 是指 chmod 用户命令, 而 &man.chmod.2; 是指系统调用。 如果您已经知道命令的名字,只是不知道要怎样使用的话,那就比较好办。 但您连名字都不知道呢?这个时候您就可以利用 man 的搜寻功能, 它会在手册的介绍部份找寻您要搜寻的关键字,它的选项是 &prompt.user; man -k mail 当您使用这个命令的时候,man会把介绍里含有mail关键字 的命令列出来,实际上这和apropos命令的功能是相同的。 有时您会看到/usr/bin 下有许多命令但不知他们的用途, 您只需这样做: &prompt.user; cd /usr/bin &prompt.user; man -f * 或者这样做 &prompt.user; cd /usr/bin &prompt.user; whatis * 两个命令是一样的。 GNU Info 文件 Free软件基金会 FreeBSD许多应用软件以及实用工具来自Free软件基金会(FSF)。 作为手册的扩充,这些程序提供了一种更具有活力的超文档说明info, 您可用info命令来阅读他们。 假如您装上emacs,也能利用emacs 的info模式来阅读。 使用 &man.info.1; 这个命令只需简单地输入: &prompt.user; info 想得到简单介绍, 请按 h。 想快速得到的命令说明, 请按 ?
diff --git a/zh_CN.GB2312/books/handbook/book.sgml b/zh_CN.GB2312/books/handbook/book.sgml index 35fc18c2f0..dfa40d27bf 100644 --- a/zh_CN.GB2312/books/handbook/book.sgml +++ b/zh_CN.GB2312/books/handbook/book.sgml @@ -1,340 +1,337 @@ %books.ent; %chapters; %txtfiles; - %pgpkeys; ]> FreeBSD 使用手册 The FreeBSD Documentation Project 1999 年 2 月 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 The FreeBSD Documentation Project &cnproj.freebsd.org; 2005 年 12 月 2003 2004 2005 2006 2007 2008 &cnproj.freebsd.org; &bookinfo.legalnotice; &tm-attrib.freebsd; &tm-attrib.3com; &tm-attrib.3ware; &tm-attrib.arm; &tm-attrib.adaptec; &tm-attrib.adobe; &tm-attrib.apple; &tm-attrib.corel; &tm-attrib.creative; &tm-attrib.cvsup; &tm-attrib.heidelberger; &tm-attrib.ibm; &tm-attrib.ieee; &tm-attrib.intel; &tm-attrib.intuit; &tm-attrib.linux; &tm-attrib.lsilogic; &tm-attrib.m-systems; &tm-attrib.macromedia; &tm-attrib.microsoft; &tm-attrib.netscape; &tm-attrib.nexthop; &tm-attrib.opengroup; &tm-attrib.oracle; &tm-attrib.powerquest; &tm-attrib.realnetworks; &tm-attrib.redhat; &tm-attrib.sap; &tm-attrib.sun; &tm-attrib.symantec; &tm-attrib.themathworks; &tm-attrib.thomson; &tm-attrib.usrobotics; &tm-attrib.vmware; &tm-attrib.waterloomaple; &tm-attrib.wolframresearch; &tm-attrib.xfree86; &tm-attrib.xiph; &tm-attrib.general; 欢迎使用 FreeBSD! 本手册适用于安装 FreeBSD &rel2.current;-RELEASEFreeBSD &rel.current;-RELEASE 以及它们的日常使用。 这个手册目前由很多人 持续地 维护。 其中的内容需要不断地更新。 如果您有兴趣参加这个项目,请发邮件到 &a.doc;。此文档最新的英文原始版本可以从 FreeBSD Web站点 上获得 (这本手册的较早期版本可以在 找到), 由 &cnproj.freebsd.org; 维护的最新译本可以在 &cnproj.freebsd.org; 快照 Web 站点&cnproj.freebsd.org; 文档快照 处获得, 这一译本会不断向主站同步。 此外, 您也可以从 FreeBSD 的 FTP 服务器 或众多的 镜像站点 得到这份文档的各种其他格式以及压缩形式的版本。 如果您更希望得到一份印刷版本的手册, 可以从 FreeBSD Mall 购买。 您还可以 搜索手册 &chap.preface; 起步 手册的以下章节主要是针对刚开始使用 FreeBSD 的用户及管理员: FreeBSD 入门。 安装过程向导。 教您 &unix; 基本知识和基本原理。 展示如何在 FreeBSD 上安装大量的第三方应用程序。 介绍使用 X,&unix; 窗口系统,以及为一些生产环境配置桌面环境的细节。 我们尝试用最少的页数来保持前言的索引,以至于可以用最少翻页次数将该手册从头至尾读过。 常见的任务 前面已经介绍了必要的基础知识, 手册的这一部分将讨论 FreeBSD 的一些最常用的功能。 这些章节包括: 向您介绍流行和实用的桌面应用程序: 浏览器、产品工具、文档察看程序,等等。 向您介绍一系列可以在 FreeBSD 上使用的多媒体工具。 介绍构建定制的 FreeBSD 内核以启用附加功能的方法。 详细介绍包括桌面和网络打印机在内的打印系统设置。 向您展示如何在 FreeBSD 上运行 Linux 应用程序。 某些章节希望您首先阅读过其他部分,在这些章的开头部分也会给出类似的提示。 系统管理 FreeBSD 手册中其余章节的内容都是关于系统管理。每一章节都从描述开始,由浅入深。 这些章节被设计成很多相对完整的部分,如果您需要了解某部分内容,直接阅读这部分内容即可,无需按照顺序,也不用在您使用 FreeBSD 的时候需要先读一遍。 网络通讯 FreeBSD 是目前以高性能网络服务为目的而部署范围最广的操作系统之一。 讨论这些话题的章节包括: 串口通讯 PPP 和以太网上的 PPP 电子邮件 运行网络服务 防火墙 其他高级网络话题 这些章节主要供您在需要时参考。 不需要以特定的顺序来阅读它们, 此外, 您开始在网络中使用 FreeBSD 之前也不必把它们都读完。 - 附录 &chap.colophon; diff --git a/zh_CN.GB2312/books/handbook/boot/chapter.sgml b/zh_CN.GB2312/books/handbook/boot/chapter.sgml index faeb9af59f..0c910142c0 100644 --- a/zh_CN.GB2312/books/handbook/boot/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/boot/chapter.sgml @@ -1,720 +1,874 @@ FreeBSD 引导过程 概述 引导 启动电脑以及加载操作系统的过程被称为引导过程, 或者简称为引导。 FreeBSD 的引导过程给用户自定义启动提供了很大的伸缩性, 您可以选择启动不同的操作系统,或者是同一系统的不同版本及内核。 本章将详细介绍您能在 FreeBSD 引导过程中设置的配置选项。 这包括了引导内核、探测设备并启动 &man.init.8; 等等之前所发生的所有事情。 这些事项一般发生在文本由白变灰时。 读完这章您将会知道: FreeBSD 引导系统里的各项组件, 以及它们之间的交互方式. 在 FreeBSD 引导时给各组件配置选项以控制引导过程。 &man.device.hints.5;的基本知识。 只适用于x86 本章只描述了运行于 Intel x86 体系之上的 FreeBSD 的引导过程。 引导问题 启动电脑及启动和引导操作系统构成了一个有趣的两难境地。 按照定义在操作系统被启动之前计算机是无法完成任何任务的,包括运行磁盘上的程序。 如果计算机在没有操作系统的情况下不能运行来自于磁盘上的程序而操作系统又是放在磁盘上的, 那操作系统是如何启动的呢? Munchausen男爵历险记 (The Adventures of Baron Munchausen) 这本书中有一个和这个过程类似的故事, 一个人掉到了下水管道里, 然后靠着拉自己的靴襻 (bootstrap) 克服重重困难爬了出来。 在早期文献中, 多以术语 bootstrap 来指代操作系统的加载机制, 如今它逐渐被简写为 booting BIOS 基本输入/输出系统BIOS 在 x86 硬件体系中,基本输入/输出系统 (BIOS) 负责加载操作系统, 为了做到这一点,BIOS 在磁盘上寻找主引导记录 (MBR),而 MBR 必须在放置的磁盘的特定位置。BIOS 有足够的能力来读入和运行 MBR, 且假使地认为 MBR 能完成加载操作系统的剩余任务, MBR可能需要BIOS的帮助。 Master Boot Record (MBR) Boot Manager Boot Loader 在MBR中的代码通常被提为引导管理器, 尤其是与用户交互的那类。这一类引导器通常有更多代码位于磁盘第一 轨道或在操作系统的文件系统中。 (引导管理器有时也被称为boot loader, 但是FreeBSD对后面的引导阶段才使用这个术语。) 流行的引导管理器包括boot0(亦称Boot Easy,标准的 &os; 引导管理器)、 GrubGAG,以及 LILO。 (只有boot0能装得进MBR。) 如果您只安装了一个操作系统,那么一个标准的 MBR 就足够了。 这个 MBR 先在磁盘上搜索可引导的(亦称“活动的”)分区, 然后运行分区上的代码以加载操作系统的其它部分。 MBR由&man.fdisk.8;安装,是一个缺省的MBR。相关文件为 /boot/mbr 如果您在磁盘上安装了多个操作系统那么您可以安装一个不同的 引导管理器,它能显示一张操作系统的列表,您能从中选择启动哪个。 这样的两种引导器将在下一小节中讨论。 启动系统的剩余部分被分为三个阶段。第一阶段由 MBR 执行,它只是使计算机进入特定的状态然后执行第二阶段。 第二阶段稍微干得多一些。第三阶段完成加载操作系统的任务。 工作被分为三个阶段是因为 PC 标准对第一第二阶段执行的程序的大小有所限制。 把这些任务连在一起使得 FreeBSD 可以提供更大伸缩性的加载器 (loader)。 内核 init 然后内核启动,它开始探测设备并初始化它们。 一旦内核引导进程完成任务,内核将控制权交给用户进程 &man.init.8;, 它确认磁盘是否处于可用状态。&man.init.8; 然后开始用户级资源配置: 加载文件系统启动网卡,及粗略地启动所有 FreeBSD 系统加载时经常运行的进程。 引导管理器和各引导阶段 Boot Manager The Boot Manager 主引导记录 (MBR) 在MBR或引导管理器中的代码有时被提为引导过程的 阶段0。这一小节便是前面提到引导器中的两种: boot0LILO <application>boot0</application>引导管理器: 由 FreeBSD 的安装程序以及 boot0cfg(8) 所安装的 MBR, 默认基于 /boot/boot0。 (程序boot0非常简单, 由于在MBR中的程序只能有446字节长, 分区表和MBR末端的0x55AA标识也要挤占一些空间。) 如果你已经安装boot0 并且有多个操作系统在你的硬盘上, 那么你如果您安装了 FreeBSD MBR 而且安装了多个操作系统, 则会在系统启动时看到类似下面的提示: <filename>boot0</filename> 截屏 F1 DOS F2 FreeBSD F3 Linux F4 ?? F5 Drive 1 Default: F2 目前已经知道一些其它操作系统,特别是 &windows; , 会以自己的 MBR 覆盖现有 MBR。 如果发生了这种事情, 或者您想用 FreeBSD 的 MBR 覆盖现有的 MBR,您可以使用以下的命令: &prompt.root; fdisk -B -b /boot/boot0 device device 是要写入 MBR 的设备名,比如 ad0 代表第一个 IDE 磁盘,ad2 代表第二个 IDE 控制器上的第一个 IDE 磁盘, da0 代表第一个 SCSI 磁盘,等等。 抑或,如果你需要一个自行配置的MBR,请使用&man.boot0cfg.8;。 The LILO Boot Manager: 要想安装这个引导管理器并也用来引导FreeBSD, 首先启动Linux,并将以下选项加入到已有的配置文件 /etc/lilo.conf other=/dev/hdXY table=/dev/hdX loader=/boot/chain.b label=FreeBSD 在上面的内容里,使用Linux的标示符指定了FreeBSD的主分区和驱动器, 将X替换为Linux驱动器字母, 将Y替换为Linux主分区号。 如果您使用的是 SCSI 驱动器,您需要将 /dev/hd 改成 /dev/sd, 这里再次使用了 XY 的语法。 如果您安装的两个系统在同一驱动器上, 选项可以去掉。现在您可以执行 /sbin/lilo -v 使修改生效;应检查屏幕上的消息确认修改。 第一阶段,<filename>/boot/boot1</filename>,和第二阶段, <filename>/boot/boot2</filename> 概念上,第一,第二阶段同属于一个程序,处于磁盘的相同区域。但由于空间限制, 它们被分为两部分。可是您总是会一起安装它们。它们由安装器或 bsdlabel(见下文)复制自被组合而成的 /boot/boot 它们位于文件系统外,引导分区的第一轨道,从第一扇区开始。在这里boot0,或者任何其它引导管理器, 期望找到一个程序运行,继续引导进程。 所使用的扇区数可由/boot/boot的大小确定。 boot1 非常简单,因为它再多也只能有 512 字节, 只能识别储存着分区信息的 bsdlabel, 及寻找执行 boot2 boot2 稍微有点加强,能够理解 FreeBSD 的文件系统以便于寻找里面的文件, 能提供选择内核和加载器的简单界面。 因为 loader 有着更强的功能, 提供了一套易于使用的引导配置,boot2 一般都执行 loader, 但以前它的任务是直接运行内核。 <filename>boot2</filename> 的屏幕输出 >> FreeBSD/i386 BOOT Default: 0:ad(0,a)/boot/loader boot: 如果您要更改已安装的 boot1boot2,请使用命令 &man.bsdlabel.8;。 &prompt.root; bsdlabel -B diskslice diskslice 是用于引导的磁盘和分区, 比如 ad0s1 代表第一个 IDE 磁盘上的第一个分区。 dangerously dedicated 如果您在 &man.bsdlabel.8; 命令中只使用了磁盘名,比如 ad0,就会破坏磁盘上的所有分区。 这当然不是您所希望的,所以在按下 回车 之前 一定要对命令进行多次确认。 第三阶段,<filename>/boot/loader</filename> boot-loader 加载器 (loader) 是三个阶段中的最后阶段, 且是放置在文件系统之中的,一般是文件 /boot/loader loader 被作为一种友好的配置方式,使用了一组内建且易用的命令集。 这些命令由一个强大的多的解释器支持构建,其本身带有复杂得多的命令集。 Loader 程序流程 初始时,loader 会探测控制台和磁盘,识别是从哪块盘引导的。 它会根据这些信息设置变量, 启动解释器以接受通过脚本或交互方式传来的用户命令。 loader loader 配置 loader 然后会读取并运行 /boot/loader.rc, 默认地读取 /boot/defaults/loader.conf 以设置可靠的默认变量,读取 /boot/loader.conf 对这些变量作本地修改。loader.rc 依据这些变量进行动作,加载任何被选择的模块和内核。 最后,默认地,loader 会停留 10 秒等待按键, 若没有发生中断,就开始引导内核。如果被中断,用户会得到一个命令行提示符, 在这里用户得更改变量、卸载所有模块、加载模块、最后引导 或重新引导。 Loader 内建的命令 这些是最常用的 loader 命令.对所有可用命令的解释请参见 &man.loader.8;。 autobootseconds 在给定的时间内如果没有中断发生就引导内核。它显示一个倒数计时, 默认的时间范围是 10 秒。 boot -options kernelname 立即按照给定的选项 (如果有的话) 和内核名 (如果是内核的) 引导内核。 boot-conf 基于变量对各种模块进行自动配置 (和引导内核时发生的一样)。 您只须记住要先使用 unload 命令, 然后修改一些变量,比如 kernel help topic 显示从文件 /boot/loader.help 读取的帮助信息。如果给定的主题是 index, 那么列出来的是所有可用的主题。 include filename 通过给定的文件名处理文件。文件被读入,然后被一行一行地解释。 任何错误都会立即中止 include 命令。 load type filename 加载内核、内核模块,或者是给定类型的文件 (通过给定的文件名)。 任何在文件名后面的参数都会被传给文件。 ls path 显示给定路径或者是根目录 (如果路径没有指定) 下面的文件列表。 如果指定了 选项,文件大小也会显示。 lsdev 列出所有可以加载模块的设备。 如果指定了 选项,会显示出更多的细节。 lsmod 显示已被加载的模块。如果指明了 选项, 会显示更多的细节。 more filename 显示指定的文件,每隔 LINES 停顿一次。 reboot 立即重启系统。 set variable set variable=value 设置 loader 的环境变量。 unload 移除所有已被加载的模块。 Loader 示例 这里有一些实际中 loader 用法的示例 single-user mode 只是简单的引导默认内核,不同的是进入单用户模式: boot -s 卸载默认内核和模块,然后加载旧的 (或者其它) 的内核: kernel.old unload load kernel.old 您可以使用被称为通用内核的 kernel.GENERIC, 或者您以前安装的内核 kernel.old (当您升级或配置了您自己的内核等时候)。 使用以下命令加载常用的模块和另一个内核: unload set kernel="kernel.old" boot-conf 加载内核配置脚本: load -t userconfig_script /boot/kernel.conf + + + + + + Joseph J. + Barbish + Contributed by + + + + + 启动时的 Splash 图像 + + 在启动时出现的 splash 图像比起原本的启动信息更加可视话。 + 这个图像将被始终显示在屏幕上直到出现控制台的登录提示或者 + X 显示管理器提供了登录画面。 + + 在 &os; 系统中有两个基本的环境。 + 第一个是默认传统的控制台命令行环境。 在系统启动之后, + 会在控制台上出现一个登录提示。 第二个环境是 X11 + 桌面图形环境。 在安装了 X11 + 和一种图形 桌面环境, + 比如 GNOME, + KDE, 或者 + XFce, + X11 桌面可以用 startx 命令运行。 + + 比起传统基于字符的登录提示,有些用户可能更喜欢 X11 + 图形化的登录界面。 图形化的登录管理器像 + &xorg; 的 XDM, + GNOMEgdm, + KDEkdm + (还有其他 Port Collection 中的) + 基本上都提供了一个图形化的登录界面代替控制台上的登录提示符。 + 在成功登录之后, 它们展现给用户一个图形化的桌面。 + + 在命令行环境, splash + 图像将在显示登录提示符之前隐藏所有启动时的监测与任务启动的消息。 + 在 X11 环境, 用户将会获得一个视觉上更加清爽启动体验, + 类似于某些像 (µsoft; &windows; 或者非 &unix; 类型的系统) + 用户所希望体验到的。 + + + Splash 图像功能 + + 目前的 splash 图像的功能仅限于支持 256 色的位图 + (.bmp) 或者 ZSoft + PCX (.pcx) 文件。 + 此外, splash 图像文件的分辨率必须是 320x200 像素或者更少, + 才够能在标准 VGA 适配器上使用。 + + 要使用尺寸更大的图像, 达到最大分辨率 1024x768 像素, + 则需开启 &os; 的 VESA 支持。 + 这可以通过在系统启动时加载 VESA 模块完成, + 或者在内核配置文件中加入 VESA 选项并编译 + (参阅 )。 VESA + 支持给予了用户显示覆盖整个显示器的启动画面能力。 + + 在启动的时候 splash 图像就会被显示在屏幕上, + 它可以在任何时候都按任意键关闭。 + + Splash 图像同样也会是 X11 之外默认的屏幕保护。 + 在一段时间的闲置后,屏幕便会转为周期性的变换显示 splash 图像, + 从明亮至暗淡, 周而复始。 默认的 splash 图像 (屏幕保护) + 可由 /etc/rc.conf 中的 + saver= 选项控制。 + saver= 选项有一些内置的屏幕保护可供选择, + 完整的列表可以再 &man.splash.4; 手册页中找到。 + 默认的屏幕保护被称为 warp。 + 请注意在 /etc/rc.conf 中所指定 + saver= 选项仅限应用于虚拟控制台。 + 对于 X11 图形化的登录管理器无效。 + + 一些有关启动引导器的信息, + 包括启动选项菜单和一个定时倒数提示符都会在启动是显示, + 即是开启了 splash 图像功能。 + + splash 图像文件样本可以从 + 下载。 + 安装了 sysutils/bsd-splash-changer + port 之后, 每次启动的时候便能从集合中随机选择 + slash 图像。 + + + + + 开启 Splash 图像功能 + + Splash 图像 (.bmp) 或者 + (.pcx) 文件必须放置在 root 分区上, + 比如 /boot 目录。 + + 对于默认的显示分辨率 (256 色,320x200 像素或更少) + 编辑 /boot/lodaer.conf, + 添加如下的设置: + + splash_bmp_load="YES" +bitmap_load="YES" +bitmap_name="/boot/splash.bmp" + + 对于更高的分辨率,最大至 1024x768 像素, + 编辑 /boot/lodaer.conf, + 添加如下的设置: + + vesa_load="YES" +splash_bmp_load="YES" +bitmap_load="YES" +bitmap_name="/boot/splash.bmp" + + 以上这些设置假设 + /boot/splash.bmp + 为需要被使用的 splash 图像。 当需要使用 PCX + 文件的时候, 添加入下列设置, 根据分辨率的高低添加 + vesa_load="YES" + splash_pcx_load="YES" +bitmap_load="YES" +bitmap_name="/boot/splash.pcx" + + 文件名并不限于以上例子中的 splash。 + 它可以是任何名称,只要是 BMP 或者 + PCX 类型的文件, 比如 + splash_640x400.bmp + 或者 + blue_wave.pcx. + + 一些有趣的 loader.conf 选项: + + + + beastie_disable="YES" + + + 这将关闭显示启动选项菜单, + 但是倒数记时仍然会出现。 即是在启动菜单选项被禁用的时候, + 在倒数记时段键入相应的启动选项仍然有效。 + + + + + loader_logo="beastie" + + + 这将替换启动选项菜单右侧默认显示的 + &os; 为彩色的小魔鬼标志, + 就像以往的发行版那样。 + + + + + 请参阅 &man.splash.4;, &man.loader.conf.5; 和 + &man.vga.4; 手册页获取更多详细信息。 + + 内核在引导时的交互 内核 引导交互 一旦内核被 loader (一般情况下) 或者 boot2 (越过 loader) 加载, 它将检查引导标志,如果有的话,就会进行必要的动作调整。 内核 引导标志 内核引导标志 这里是一些常用的引导标志: 在内核初始化时,询问作为根加载的设备。 从 CDROM 引导。 运行 UserConfig (引导时的内核配置器) 引导进入单用户模式 在内核引导过程中显示更有的信息 还有更多的引导标志,阅读 &man.boot.8; 以获取有关它们的信息。 Tom Rhodes Contributed by device.hints Device Hints 这是 FreeBSD 5.0 及其以后版本的组件, 不存在于早前的版本中。 在初始化系统启动时,&man.loader.8; 会读取 &man.device.hints.5; 文件。这个文件以变量的形式储存着内核引导信息, 有时被称为 device hints。 设备驱动程序用device hints 对设备进行配置。 Device hints 也可以在 第三阶段的boot loader 的命令行提示符中指定。变量可以用 set 命令添加,unset 命令删除, show 命令查看。在文件 /boot/device.hints 设置的变量亦可以在这里被覆盖。键入 boot loader 中的变量不是永久性的,在下次启动时就会被忘记。 一旦系统引导成功,&man.kenv.1; 命令可以用来清楚所有的变量。 文件 /boot/device.hints 的语法是一行一个变量, 使用#作为注释标记。 每行是按照如下方式组织的: hint.driver.unit.keyword="value" 第三阶段 boot loader 的语法是: set hint.driver.unit.keyword=value driver 是设备驱动程序名,unit 是设备驱动程序单位名,keyword 是 hint 关键字。 关键字可以由以下选项组成: at:指明设备所绑定的总线 port:指明所使用 I/O 的起始地址。 irq:指明所使用的中断请求号。 drq:指明 DMA channel 号。 maddr:指明设备占用的物理内存地址。 flags:给设备设置各种标志位。 disabled:如果设成 1, 设备被禁用。 设备驱动程序能够接受更多的 hints,推荐您参看它们的联机手册。参看 &man.device.hints.5;、&man.kenv.1;、&man.loader.conf.5; 和 &man.loader.8; 联机手册以获取更多的信息。 init Init:进程控制及初始化 一旦内核完成引导,它就把控制权交给了用户进程 &man.init.8;,它放置在 /sbin/init, 或者 init_path 变量指定的程序路径中。 这个变量是在 loader 里面设置的。 自动重启过程 自动重启过程会确认系统中可用的文件系统处于健康的状态。 如果不是, 而且使用 &man.fsck.8; 也无法修复这些问题, &man.init.8; 会进入 单用户模式 以便系统管理员直接修正这些问题。 单用户模式 单用户模式 控制台 此模式可以通过 自动重启过程 或者通过带有 选项的用户引导或通过在 loader 里设置 boot_single 变量等多种方式来达到。 也可以在多用户模式下调动无重启 () 选项和停机 () 选项的 &man.shutdown.8; 命令来进入单用户模式。 如果系统 控制台 在文件 /etc/ttys 中被设置为 不安全(insecure), 在初始化单用户模式前会出现要求输入 root 密码的命令行提示符。 在 <filename>/etc/ttys</filename> 文件中的不安全控制台 # name getty type status comments # # If console is marked "insecure", then init will ask for the root password # when going to single-user mode. console none unknown off insecure 把控制台设置成 不安全 (insecure) 使只知道 root 密码的人才能进入单用户模式, 因为您认为控制台在物理上是不安全的。因此如果您考虑到安全性, 请选择 不安全 (insecure),而非 安全 (secure) 多用户模式 多用户模式 如果 &man.init.8; 发现您的文件系统一切正常,又或者用户在单用户模式完成了工作, 系统就会进入多用户模式,开始系统的资源配置。 rc 文件 资源配置 (rc) 资源配置分别从文件 /etc/defaults/rc.conf/etc/rc.conf 中读取默认配置和细节配置, 然后加载在文件 /etc/fstab 中提及的文件系统、 启动网络服务、启动各种系统守护进程,最后启动本地安装包的启动脚本。 &man.rc.8; 联机手册是关于资源配置的很好的参考。 关机 (shutdown) 过程 shutdown 由命令 &man.shutdown.8; 的发起的关机过程中, &man.init.8; 会试着运行 /etc/rc.shutdown 脚本, 给所有进程发送 TERM 信号, 最后给不按时停止的进程发送 KILL 信号。 在支持电源管理的平台上关闭 FreeBSD 系统的电源, 只要简单地使用命令 shutdown -p now 即可。 此外, 可以用命令 shutdown -r now 来重启 FreeBSD。 要执行 &man.shutdown.8; 您必须是 root 用户或 operator 组的成员。 也可以使用 &man.halt.8; 和 &man.reboot.8; 命令来关闭系统, 请参看它们的联机手册以获得更多的信息。 电源管理需要支持, 这要求内核支持 &man.acpi.4; 或以模块形式加载它。 diff --git a/zh_CN.GB2312/books/handbook/chapters.ent b/zh_CN.GB2312/books/handbook/chapters.ent index 6368fe5159..df8aeee871 100644 --- a/zh_CN.GB2312/books/handbook/chapters.ent +++ b/zh_CN.GB2312/books/handbook/chapters.ent @@ -1,65 +1,64 @@ - diff --git a/zh_CN.GB2312/books/handbook/cutting-edge/chapter.sgml b/zh_CN.GB2312/books/handbook/cutting-edge/chapter.sgml index 3c52c08433..51ad128bc3 100644 --- a/zh_CN.GB2312/books/handbook/cutting-edge/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/cutting-edge/chapter.sgml @@ -1,1564 +1,1997 @@ - + Jim Mock 重新组织和部分更新,由 Jordan Hubbard 原创: Poul-Henning Kamp John Polstra Nik Clayton 雪平 中文翻译: - 最前沿 + 更新与升级 &os; - + 概述 - &os; 在两个发行版之间都有着持续的发展。 - 对于喜欢冒险的人来说,有几种机制让您的系统与最新的发展保持同步。 - 警告—冒险并不适合每一个人! - 本章将有助于您决定是紧跟最新发展还是坚持发行版。 + &os; 在发行版之间始终是持续开发的。 一些人喜欢使用官方发行的版本, + 另一些喜欢与最新的开发保持同步。 然而, + 即使是官方的发行版本也常常需要安全补丁和重大修正方面的更新。 + 不论你使用了何种版本, &os; 都提供了所有更新系统所需的工具, + 让你轻松的在不同版本间升级。 + 这一章节将帮助你决定是跟踪开发系统还是坚持使用某个发行的版本。 + 同时还列出了一些保持系统更新所需的基本工具。 读了本章后,您将了解到: - &os.stable; 和 &os.current;两个开发分支的不同点。 + + 使用哪些工具来更新系统与 Ports Collection。 - 怎样使用CVSup, - CVS或 - CTM保持您的系统更新。 + + + 如何使用 + freebsd-update, + CVSup, + CVS, or + CTM + 让你的系统保持更新。 + + + + 如何比较已安装的系统与原来已知拷贝的状态。 - 如何使用 make buildworld - 等命令来重新编译和安装基本系统。 + + + 两个开发分支 &os.stable; 和 &os.current; + 的区别。 + + 如何通过 make buildworld + 重新编译安装整个基本系统(等等)。 + 在读本章这前,您应该了解的: 正确设置网络连接 ()。 知道怎样安装附加的第三方软件()。 整个这一章中,cvsup 命令都被用来获取 &os; 源代码的更新。 你需要安装一个像 net/cvsup-without-gui 这样的 port 或者二进制包。 如果你使用的是 &os; 6.2-RELEASE 或之后的版本, 你可以使用 &man.csup.1; 代替, 现在它已经是基本系统的一部分了。 + + + + + Tom + Rhodes + Written by + + + + + Colin + Percival + Based on notes provided by + + + + FreeBSD 更新 + + Updating and Upgrading + + freebsd-update + updating-upgrading + + + 打安全补丁是对于维护计算机软件的一个重要部分, + 特别是对于操作系统。对于 &os; 来说, + 很长的一段时间以来这都不是一件容易的事情。 + 补丁打在源代码上,代码需要被重新编译为二进制, + 然后再重新安装编译后的程序。 + + &os; 引入了 freebsd-update + 工具之后这便不再是问题了。这个工具提供了 2 种功能。 + 第一,它可以把二进制的安全和勘误更新直接应用于 &os; + 的基本系统,而不需要重新编译和安装。第二, + 这个工具还支持主要跟次要的发行版的升级。 + + + 由安全小组支持的各种体系结构和发行版都可使用二进制更新。 + 然而有些特性,比如升级 &os; 操作系统需要最近的 &man.freebsd-update.8; + 和 &os; 6.3。在升级到一个新的发行版本之前, + 应先阅读一下当前发行版的声明, + 因为他们可能包含有关于你期望升级版本的重要消息。 + 这些发行声明可以通过以下链接查阅: + + + + 如果 crontab 中存在有用到 + freebsd-update 特性的部分, + 那么这些在开始以下操作前必须先被禁止。 + + + 配置文件 + + 有些用户可能希望调整配置文件来更好的控制升级过程。 + 可用参数的文档非常齐全, + 但下面的这些可能需要进一步的解释: + + # Components of the base system which should be kept updated. +Components src world kernel + + 这个参数是控制 &os; 的哪一部分将被保持更新。 + 默认的是更新源代码,整个基本系统还有内核。 + 这些部件跟安装时的那些相同,举例来说, + 在这里加入 “world/games” 就会允许打入游戏相关的补丁。 + 使用 “src/bin” 则是允许更新 + src/bin + 目录中的源代码。 + + 最好的选择是把这个选项保留为默认值, + 因为如果要修改它去包含一些指定的选项, + 就需要用户列出每一个想要更新的项目。 + 这可能会引起可怕的后果, + 因为部分的源代码和二进制程序得不到同步。 + + # Paths which start with anything matching an entry in an IgnorePaths +# statement will be ignored. +IgnorePaths + + 添加路径,比如 + /bin 或者 + /sbin + 让这些指定的目录在更新过程中不被修改。 + 这个选项能够防止本地的修改被 + freebsd-update 覆盖。 + + # Paths which start with anything matching an entry in an UpdateIfUnmodified +# statement will only be updated if the contents of the file have not been +# modified by the user (unless changes are merged; see below). +UpdateIfUnmodified /etc/ /var/ /root/ /.cshrc /.profile + + 更新指定目录中的未被修改的配置文件。 + 用户的任何修改都会使这些文件的自动更新失效。 + 还有另外一个选项, + KeepModifiedMetadata, + 这个能让 freebsd-update + 在合并时保存修改。 + + # When upgrading to a new &os; release, files which match MergeChanges +# will have any local changes merged into the version from the new release. +MergeChanges /etc/ /var/named/etc/ + + 一个 freebsd-update + 应该尝试合并的配置文件的列表。文件合并的过程是 + 一系列的 &man.diff.1; 补丁类似于更少选项的 &man.mergemaster.8; + 合并的选项是接受,打开一个文本编辑器,或者 + freebsd-update 会被中止。 + 在不能确定的时候,请先备份 /etc + 然后接受合并。更多关于 mergemaster + 的信息请参阅 + + # Directory in which to store downloaded updates and temporary +# files used by &os; Update. +# WorkDir /var/db/freebsd-update + + 这个目录是放置所有补丁和临时文件的。 + 用户做一个版本升级的话,请确认此处至少有 1 GB + 的可用磁盘空间。 + + # When upgrading between releases, should the list of Components be +# read strictly (StrictComponents yes) or merely as a list of components +# which *might* be installed of which &os; Update should figure out +# which actually are installed and upgrade those (StrictComponents no)? +# StrictComponents no + + 当设置成 yes 时, + freebsd-udpate 将假设这个 + Components 列表时完整的, + 并且对此列表以外的项目不会修改。实际上就是 + freebsd-update 会尝试更新 + Componets + 列表里的每一个文件。 + + + + 安全补丁 + + 安全补丁存储在远程的机器上, + 可以使用如下的命令下载并安装: + + &prompt.root; freebsd-update fetch +&prompt.root; freebsd-update install + + 如果给内核打了补丁,那么系统需要重新启动。 + 如果一切都进展顺利,系统就应该被打好了补丁而且 + freebsd-update 可由夜间 + &man.cron.8; 执行。在 /etc/crontab + 中加入以下条目足以完成这项任务: + + @daily root freebsd-update cron + + 这条记录是说明每天运行一次 + freebsd-update。用这种方法, + 使用了 参数, + freebsd-update 仅检查是否存在更新。 + 如果有了新的补丁,就会自动下载到本地的磁盘, + 但不会自动给系统打上。root + 会收到一封电子邮件告知需手动安装补丁。 + + 如果出现了错误,可以使用下面的 + freebsd-update + 命令回退到上一次的修改: + + &prompt.root; freebsd-update rollback + + 完成以后如果内核或任何的内核模块被修改的话, + 就需要重新启动系统。这将使 &os; + 装载新的二进制程序进内存。 + + + freebsd-update 只能应用于 + GENERIC 内核。如果对 + GENERIC + 做了任何修改或者安装了一个自行编译的内核, + freebsd-update + 就无法完成升级 — 如前一个范例那样失败后 + 产生一条错误信息。 + + + + + 重大和次要的更新 + + 这个过程会删除旧的目标文件和库, + 这将使大部分的第三方应用程序无法删除。 + 建议将所有安装的 ports 先删除然后重新安装,或者稍后使用 + ports-mgmt/portupgrade + 工具升级。 大多数用户将会使用如下命令尝试编译: + + &prompt.root; portupgrade -af + + 这将确保所有的东西都会被正确的重新安装。 + 请注意环境变量 BATCH 设置成 + yes 的话将在整个过程中对所有询问回答 + yes,这会帮助在编译过程中免去人工的介入。 + + 重大和次要的更新可以由 + freebsd-update 命令后指定一个发行版本来执行, + 举例来说,下面的命令将帮助你升级到 &os; 6.3: + + &prompt.root; freebsd-update -r 6.3-RELEASE upgrade + + 在这个命令被执行后,freebsd-update + 将会先解析配置文件和评估当前的系统以获得更新系统所需的必要信息。 + 然后便会显示出一个包含了已检测到与未检测到的组件列表。 + 例如: + + Looking up update.FreeBSD.org mirrors... 1 mirrors found. +Fetching metadata signature for 6.3-BETA1 from update1.FreeBSD.org... done. +Fetching metadata index... done. +Inspecting system... done. + +The following components of FreeBSD seem to be installed: +kernel/smp src/base src/bin src/contrib src/crypto src/etc src/games +src/gnu src/include src/krb5 src/lib src/libexec src/release src/rescue +src/sbin src/secure src/share src/sys src/tools src/ubin src/usbin +world/base world/info world/lib32 world/manpages + +The following components of FreeBSD do not seem to be installed: +kernel/generic world/catpages world/dict world/doc world/games +world/proflibs + +Does this look reasonable (y/n)? y + + 此时,freebsd-update + 将会尝试下载所有升级所需的文件。在某些情况下, + 用户可能被问及需安装些什么和如何进行之类的问题。 + + 下载完所有的补丁之后,它们很快就会被打上。 + 这个过程可能会持续一段时间,取决与机器的速度和当前的负载情况。 + 配置文件将会被合并 — 这一部分需要用户的参与, + 因为文件可能被合并或者屏幕上弹出了一个文本编辑器用来手工合并。 + 在处理过程中,每一个成功的合并都会给用户显示出来。 + 失败或者被忽略的合并则会引起合并程序的中止。 + 用户可能想要备份一下 /etc + 之后手工合并重要的文件,比如 + master.passwd 或 + group + + + 系统至此还没有被修改,所有的补丁和合并都在另外一个目录中进行。 + 当所有的补丁都被成功的打上了以后,所有的配置文件都被合并后, + 我们就已经完成了整个升级过程中最困难的部分, + 下面就需要用户来安装这些变更了。 + + + 一旦这个步骤完成后,使用如下的命令将升级后的文件安装到磁盘上。 + + &prompt.root; freebsd-update install + + 内核与内核模块会先被打上补丁。此时机器必须要重新启动。 + 使用下面的命令重启机器,这样新的内核将载入内存: + + &prompt.root; shutdown -r now + + 在系统重新上线后,需要再次运行 freebsd-update。 + 升级的状态被保存着,这样 freebsd-update + 就无需重头开始,但是会删除所有旧的共享库和目标文件。 + 执行如下命令继续这个阶段的升级: + + &prompt.root; freebsd-update install + + + 取决与是否有库的版本更新,通常只有 2 个而不是 + 3 个安装阶段。 + + + 现在需要重新编译和安装第三方软件。 + 这么做的原因是某些已安装的软件可能依赖于在升级过程中已删除的库。 + 可使用 ports-mgmt/portupgrade + 自动化这个步骤,以如下的命令开始: + + &prompt.root; portupgrade -f ruby +&prompt.root; rm /var/db/pkg/pkgdb.db +&prompt.root; portupgrade -f ruby18-bdb +&prompt.root; rm /var/db/pkg/pkgdb.db /usr/ports/INDEX-*.db +&prompt.root; portupgrade -af + + 一旦这个完成了以后,再最后一次运行 + freebsd-update 来结束升级过程。 + 执行如下命令处理升级中的所有细节: + + &prompt.root; freebsd-update install + + 重新启动机器进入新版本的 &os; 升级过程至此就完成了。 + + + + 系统状态对照 + + freebsd-update + 工具也可被用来对着一个已知完好的 &os; 拷贝测试当前的版本。 + 这个选项评估当前的系统工具,库和配置文件。 + 使用以下的命令开始对照: + + &prompt.root; freebsd-update IDS >> outfile.ids + + + 这个命令的名称是 IDS, + 它并不是一个像 + security/snort + 这样的入侵检测系统的替代品。因为 + freebsd-update 在磁盘上存储数据, + 很显然它们有被篡改的可能。 + 当然也可以使用一些方法来降低被篡改的可能性,比如设置 + kern.securelevel 和不使用时把 + freebsd-update + 数据放在只读文件系统上,例如 DVD 或 + 安全存放的外置 USB 磁盘上。 + + + 现在系统将会被检查,生成一份包含了文件和它们的 &man.sha256.1; + 哈希值的清单,已知发行版中的值与当前系统中安装的值将会被打印到屏幕上。 + 这就是为什么输出被送到了 outfile.ids 文件。 + 它滚动的太块无法用肉眼对照,而且会很快填满控制台的缓冲区。 + + 这个文件中有非常长的行,但输出的格式很容易分析。 + 举例来说,要获得一份与发行版中不同哈希值的文件列表, + 已可使用如下的命令: + + &prompt.root; cat outfile.ids | awk '{ print $1 }' | more +/etc/master.passwd +/etc/motd +/etc/passwd +/etc/pf.conf + + 这份输出时删节缩短后的,其实是有更多的文件。 + 其中有些文件并非人为修改,比如 + /etc/passwd + 被修改是因为添加了用户进系统。在某些情况下, + 还有另外的一些文件,诸如内核模块与 + freebsd-update 的不同是因为它们被更新过了。 + 为了指定的文件或目录排除在外,把它们加到 + /etc/freebsd-update.conf 的 + IDSIgnorePaths 选项中。 + + 除了前面讨论过的部分之外, + 这也能被当作是对升级方法的详细补充。 + + + + + + + + Tom + Rhodes + Written by + + + + + Colin + Percival + Based on notes provided by + + + + Portsnap: 一个 Ports Collection 更新工具 + + Updating and Upgrading + + Portsnap + Updating and Upgrading + + + &os; 基本系统也包括了一个更新 Ports Collection 的工具: + &man.portsnap.8;。在运行之后,它会连上一个远程网站, + 校验安全密钥,然后下载一份 Ports Collection 的拷贝。 + 密钥是用来校验所有下载文件的完整性,确保它们在传输是未被修改。 + 使用以下的命令下载最新的 Ports Collection: + + &prompt.root; portsnap fetch +Looking up portsnap.FreeBSD.org mirrors... 3 mirrors found. +Fetching snapshot tag from portsnap1.FreeBSD.org... done. +Fetching snapshot metadata... done. +Updating from Wed Aug 6 18:00:22 EDT 2008 to Sat Aug 30 20:24:11 EDT 2008. +Fetching 3 metadata patches.. done. +Applying metadata patches... done. +Fetching 3 metadata files... done. +Fetching 90 patches.....10....20....30....40....50....60....70....80....90. done. +Applying patches... done. +Fetching 133 new ports or files... done. + + 这个例子展示的是 &man.portsnap.8; + 发现并校验了几个用于当前 ports 的补丁。这还表明以前运行过, + 如果是第一次运行的话,那么仅仅只会下载 Ports Collection。 + + 在 &man.portsnap.8; 成功完成一次 + fetch 操作后,而且本地系统上的 Ports Collection + 和随之而来的补丁通过校验以后。键入以下命令安装更新文件: + + &prompt.root; portsnap extract +/usr/ports/.cvsignore +/usr/ports/CHANGES +/usr/ports/COPYRIGHT +/usr/ports/GIDs +/usr/ports/KNOBS +/usr/ports/LEGAL +/usr/ports/MOVED +/usr/ports/Makefile +/usr/ports/Mk/bsd.apache.mk +/usr/ports/Mk/bsd.autotools.mk +/usr/ports/Mk/bsd.cmake.mk +... + + 至此更新就完成了,然后便可以使用更新后的 + Ports Collection 来安装或升级应用程序。 + + 可以使用如下的命令让这个过程连续的运行: + + &prompt.root; portsnap fetch update + + - &os.current; 和 &os.stable; 的对比 - CURRENT - STABLE + 追踪开发分支/title> + <indexterm><primary>-CURRENT</primary></indexterm> + <indexterm><primary>-STABLE</primary></indexterm> - <para>FreeBSD有两个开发分支:&os.current; 和 &os.stable;。 - 这部分将对它们都做些说明, 并介绍您的系统如何与各自的树一同保持最新。 - 我们将首先讨论 &os.current;, 随后讨论 &os.stable;。</para> + <para>FreeBSD 有两个开发分支: &os.current; 和 &os.stable;。 + 这一章节将对每个分支作相应介绍与如何保持你的系统更新。 + 我们将先介绍 &os.current; 然后是 &os.stable;。</para> <sect2 id="current"> <title>使用最新的 &os; CURRENT 这里再次强调, &os.current; 是 &os; 开发的 最前沿。 &os.current; 用户要有较高的技术能力, 并且应该有能力自已解决困难的系统问题。 如果您是个 &os; 新手, 那么在安装之前最好三思。 &os.current; 是什么? 快照 &os.current; 是 &os; 的发展前沿。 包括了在下一个官方发行的软件中可能存在, 也可能不存在的发展、 试验性改动、 以及过渡性的机制。 尽管许多 &os; 开发者每天都会编译 &os.current; 源代码, 但有时这些代码仍然会是不能编译的。 虽然这些问题会很快解决, 但 &os.current; 是带来破坏还是您正希望的功能性改善, 很可能完全取决于您获取源代码的的时机! 谁需要 &os.current;? &os.current; 适合下边三种主要兴趣团体: &os; 社区的成员: 积极工作在源码树的某部分的人和为保持 最新 为绝对需求的人。 &os; 社区的成员: 为促使 &os.current; 保持尽可能的健全而愿花时间去解决问题的积极的测试者; 以及那些愿意提出关于 &os; 变化和总体方向的建设性建议并且提供补丁实现它们的人们。 那些只是想关注或为了参考目的使用当前 (current) 源码的人们 (如,为了阅读,而不是执行)。 这些人也偶尔做做注释或贡献代码。 &os.current; <emphasis>不是</emphasis>什么? 追求最新功能, 您听说里面有一些很酷的新功能, 并希望成为您周围的人中第一个尝试它们的人。 尽管您能够因此首先了解到最新的功能, 但这也意味着在出现新的 bug 时您也首当其冲。 修复错漏的快捷方式。任何 &os.current 的既定版本在修复已知错漏的同时又可能会产生新的错漏。 无所不在的官方支持。 我们尽最大努力在3个合法的 &os.current; 组之一真诚给人们提供帮助,但是我们 没有时间提供技术支持。 这并不是因为我们是那种不喜欢帮助人解困的无耻之徒 (如果我们是的话,就不会制作 &os; 了)。 我们不能每天简单地回复上百的消息,而且 我们继续发展 FreeBSD! 在改善 &os; 和回复大量关于实验代码的问题之间如果要做个选择的话, 开发人员会选择前者。 使用 &os.current; 当前版 使用 加入 &a.current.name; 和 &a.svn-src-head.name; 列表。 这个不仅仅是个好主意,而且很 重要。如果您不去 &a.current.name;, 您就不会看到人们所做的关于系统当前状态的说明, 这样您就有可能在别人已经发现并解决了的一大堆问题面前难倒。 更重要的是您会错过一些重要的公告---对于您的系统安全可能是至关重要的。 &a.svn-src-head.name; 列表允许您看到每个变化的提交记录, 因为这些记录与其它相关信息是同步的。 要加入这些列表,或其它可能的列表,请访问 &a.mailman.lists.link; ,并且点击您想订阅的列项。 关于其它步骤的说明那里有提供。 如果你有兴趣追踪整个原代码树的变更记录, 我们建议你订阅 &a.svn-src-all.name; 邮件列表。 从&os; 镜像站点 获取源码。 您有两种方式选择: cvsup cron 当前 使用 CVSup 同步 与称作 standard-supfilesupfile 一起使用 cvsup,这个可以从 /usr/share/examples/cvsup得到。 这是最被推荐的方式,因为它允许您一次获取整个集合, 以后就只取更改过的部分。许多人从 cron 运行 cvsup,以保持他们的源码自动更新。 您须要定制上边的 supfile 样本,并且配置 cvsup 以适应您的环境。 standard-supfile 例子是为追踪指定的 &os; 安全分支而指定的, 而不是 &os.current;。 你需要编辑这个文件并把如下这行: *default release=cvs tag=RELENG_X_Y 替换为: *default release=cvs tag=. 可以参阅手册中的 CVS Tags 章节获得更多可用 tag 的详细说明。 当前的 使用 CTM 同步 使用工具 CTM。 如果您的连接性能不太好(高价连接或只能通过电子邮件存取), CTM 是个选择。 但这也颇有争议并且常常得到到坏文件。因此很少使用它, 这也注定了不能长期用它来工作。对于使用 9600 bps 或更快连接的人,我们推荐使用 CVSup 如果您获取源码是用于运行,而不只是看看,那么就获取 整个 &os.current;,不要选部分。 这样做的原因是源码的大部分都依赖于其他部分, 要是您试着只编译其中一部分的话,保证您会陷入麻烦。 当前版 编译 在编译 &os.current; 之前,请仔细阅读 /usr/src 里的 Makefile 文件。 尽管是部分的升级过程,您至少也要首先安装新的内核和重建系统。阅读 &a.current; 邮件列表和 /usr/src/UPDATING, 会让您在其它循序渐进的过程中保持最新, 这对于我们向下一个发行版转移是很有必要的。 热心一点!如果您正运行 &os.current;, 我们很想知道您关于它的一些想法, 尤其是关于错漏修复或增进的建议。 非常欢迎带有代码的建议! 使用最新的 &os; STABLE &os.stable; 是什么? 稳定版 &os.stable; 是我们的发展分支,我们的主要发行版就由此而来。 这个分支会以不同速度变化,并且假定这些是第一次进入 &os.current; 进行测试。然而,这 仍然 是个发展中的分支,这意味着在一定的时候,&os.stable; 源码可能或不可能满足一些特殊的要求。 它只不过是另一个工程发展途径,并不是终端用户的资源。 谁需要 &os.stable;? 如果您有兴趣追随 FreeBSD 的开发过程或为其做点贡献, 尤其是和下一个 非计划 的 FreeBSD 发行版有关时, 您应该考虑采用 &os.stable;。 尽管安全更新也会进入 &os.stable; 分支,但您并不 必须 使用 &os.stable; 来达到这样的目的。 每一个 FreeBSD 的安全公告都会解释如何修复受到影响的发行版中的问题 这也不总是正确。我们不可能永远支持 FreeBSD 的旧发行版, 尽管我们会在发布之后支持他们数年之久。 关于 FreeBSD 目前对于旧发行版的支持政策的完整描述, 请参见 http://www.FreeBSD.org/security/ ,而因为安全原因而去采用一个开发分支显然可能会同时引入一些不希望的修改。 尽管我们尽力确保 &os.stable; 分支在任何时候都能够正确编译和运行, 但没有人能够担保它在任何时候都总可以。 此外, 尽管代码在进入 &os.stable; 之前都是在 &os.current; 上完成开发, 但使用 &os.stable; 的人要比使用 &os.current; 的更多。 有证据显示, 犄角旮旯里的各种问题有些时候仍然会由于在 &os.current; 不那么明显 而在 &os.stable; 暴露出来。 基于这些原因, 推荐您盲目地追随 &os.stable;, 并且, 在粗略地测试过代码之前不要更新任何生产服务器到 &os.stable; 也非常重要。 如果您没有用于完成这些工作的资源, 我们推荐您使用最新的 FreeBSD 发行版, 并使用发行版提供的二进制更新机制来在发行版之间完成迁移。 使用&os.stable; 稳定版 使用 加入 &a.stable.name; 列表。让您随时了解可能出现在 &os.stable; 里的build 依赖性或其它需要特别注意的问题。 当开发员正在考虑某些有争议的修复或更新时, 他们就会在这个邮件列表里发表声明,给用户机会回应, 看他们对于提出的变化是否还有什么问题。 加入相关的 SVN 列表来追踪你所关心的分支。比如,如果你在追踪 7-STABLE 分支,加入 &a.svn-src-stable-7.name; 列表。 这样每次这个分支上有改动的时候就能让你看到提交记录, 还包括了修改可能引起的副作用之类的相关信息。 要加入这些列表或其他可用的,访问 &a.mailman.lists.link; 并点击您希望订阅的列表。关于其它步骤的说明可以在那里看到。 如果你有兴趣追踪整个原代码树的变更记录, 我们建议你订阅 &a.svn-src-all.name; 邮件列表。 如果您正安装一个新系统, 并希望它运行每月从 &os.stable; 编译的快照, 请察看 Snapshots 网页以了解更多信息。 另外, 也可以从 镜像站点 安装最新的 &os.stable; 发行版, 并按照其中的说明将系统更新到最新的 &os.stable; 源代码。 如果您已经在运行较早的 &os; 版本, 并希望通过源代码方式升级, 则可以通过 &os; 镜像站点 来完成。 这可以通过两种方式来进行: cvsup cron 稳定版 使用CVSup同步 与称作 stable-supfilesupfile 一起使用 cvsup,这个可以从 /usr/share/examples/cvsup 得到。 这是最被推荐的方式,因为它允许您一次获取整个集合, 以后就只取更改过的部分。许多人从 cron 运行 cvsup,以保持他们的源码自动更新。 您须要定制上边的 supfile 样本,并且配置 cvsup 以适应您的环境。 当前的 使用 CTM 同步 使用工具 CTM。 如果您的连接性能不太好(高价连接或只能通过电子邮件存取), CTM 是个选择。 但这也颇有争议并且常常得到到坏文件。因此很少使用它, 这也注定了不能长期用它来工作。对于使用 9600 bps 或更快连接的人,我们推荐使用 CVSup 本质上说,如果您需要快速存取源码并且不计较通信宽带的话,可以使用 cvsupftp。否则,就使用 CTM 稳定版 编译 在编译 &os.stable; 之前,请仔细阅读 /usr/src 里的 Makefile。 您至少应该安装一个新的内核并重建系统, 首先做为升级过程的一部分。阅读 &a.stable; 邮件列表和 /usr/src/UPDATING, 可能让您在其它循序渐进的过程中保持更新, 这在我们向下一发行版转移时是很有必要的。 同步您的源码 有许多方式通过互联网(或电子邮件)与 &os; 项目源码特定领域或所有领域保持更新,主要依赖于您的兴趣。 我们提供的主要服务是匿名 CVS、 CVSup,和 CTM。 虽然只更新源码树中的部分是可能的, 唯一被支持的更新过程是更新整个树、并且重编译用户区 (如:在用户空间运行的所有程序,像 /bin/sbin下边的)和内核源码。 只更新源码树中的部分,或只有内核,或只有用户区 (userland) 通常会出现错误。这些问题包括有编译错误、内核崩溃 (kernel panics)、数据出错。 CVS 匿名 匿名 CVSCVSup 使用 下拉(pull) 模式来更新源代码。 在 CVSup 中, 用户 (或者 cron 脚本) 会调用 cvsup 程序, 后者会同某一个 cvsupd 服务进行交互, 以更新您的文件。 您接到的更新是更新时刻最新的, 并且您只会收到那些需要的更新。 您可以很容易地限制更新的范围, 只更新那些您需要的文件。 服务器端会根据您手头已经有的文件即时地生成更新内容。 匿名 CVS 相对于 CVSup 而言要简单一些, 因为它只是对 CVS 的一种扩展, 让您可以从远程的 CVS 代码库得到更新。 CVSup 相对而言, 要比 匿名 CVS 更有效率, 然而后者却更容易使用。 CTM 另一种方法是 CTM。 这种方法并不能将您手头的代码与中央代码库中的版本进行比较, 也不能下载它们。 在主 CTM 服务器上运行的脚本会每天执行多次, 每次运行都能够自动地识别所有文件自上次运行以来所发生的变化, 如果发现有文件发生了变动, 就会压缩、 标上一个序列号, 并进行便于使用电子邮件进行传送的编码操作 (其中只包括可打印的 ASCII 字符)。 一旦接收到, 这些CTM deltas就会被传送给 &man.ctm.rmail.1; 工具---可以自动进行解码、校验和应用这些变化到用户的复制的源码里。 这个过程比 CVSup 更为有效, 而且更少占用我们的服务器资源,因为它不仅仅采用 下拉(pull) 模式,还采用 上推(push) 模式。 当然, 这样做也会带来一些不便。 如果您不经意删除了您的压缩包的部分内容, CVSup 会检测到并为您重建破坏的部分。 CTM 是不会这样做的, 如果您删除了您的源码树中的某部分(并已不能恢复), 那么您就必须从破坏处 (从最新的CVS base delta) 开始,使用 CTM匿名 CVS 进行重建,仅仅删除坏的数据并再同步。 重新编译 <quote>world</quote> 重新编译 world 只要您根据一定版本的 &os; (&os.stable;、&os.current; 等等), 已经同步了您本地的源码树,那么您就可以使用这些源码树来重建系统。 做好备份 无需强调在行动 之前 备份整个系统是多么的重要。 尽管重新编译系统是 (如果您按照文档的指示做的话) 一件很容易完成的工作, 但出错也是在所难免的, 另外, 别人在源码里面引入的错误也可能造成系统无法引导。 请确信自己已经做过备份, 并且在手边有恢复软盘或可以引导的光盘。 您可能永远也不会用到它, 但安全第一嘛! 订阅恰当的邮件列表 邮件列表 &os.stable; 和 &os.current; 分支自然是 发展中的。为 &os; 做贡献的都是人,偶尔也会犯错误。 有时这些错误没什么危害,只是引起您的系统生成新的诊断警告。 有时是灾难性的,并导致您的系统不能启动或破坏您的文件系统 (甚至更糟)。 如果出现了类似的问题, 贴一封小心(heads up)帖到相关的邮件列表里, 讲清问题的本质以及受影响的系统。在问题解决后,再贴封解除(all clear)声明。 如果使用 &os.stable; 或 &os.current; 而又不阅读 &a.stable; 和 &a.current; 各自的邮件列表, 那么您是自找麻烦。 不要使用 <command>make world</command> 许多较早的文档推荐使用 make world 来完成这项工作。 这样做会跳过一些必要的步骤, 因此只有在您知道自己在做什么的时候才可以这样做。 几乎所有的情况下 make world 都是不应该做的事情, 您应该使用这里描述的方法。 更新系统的规范途径 要更新系统, 就一定要首先查看 /usr/src/UPDATING 文件, 以了解 buildworld 之前需要完成的步骤, 然后使用下面的过程: &prompt.root; cd /usr/src &prompt.root; make buildworld &prompt.root; make buildkernel &prompt.root; make installkernel &prompt.root; shutdown -r now 有时, 可能需要额外地执行一次 mergemaster -p 才能够完成 buildworld 步骤。 这些要求, 会在 UPDATING 中进行描述。 一般而言, 您可以简单地跳过这一步, 只要进行的不是大跨度的 &os; 版本升级。 installkernel 成功完成之后, 您需要引导到单用户模式 (举例而言, 可以在加载器提示后输入 boot -s)。 接下来执行: &prompt.root; mount -a -t ufs &prompt.root; mergemaster -p &prompt.root; cd /usr/src &prompt.root; make installworld &prompt.root; mergemaster &prompt.root; reboot 阅读进一步的说明 前面所给出的, 只是帮助您开始工作的简要说明。 要清楚地理解每一步, 特别是如果打算自行定制内核配置, 就应阅读下面的内容。 阅读 <filename>/usr/src/UPDATING</filename> 在您做其它事之前,请阅读 /usr/src/UPDATING (或在您的源码里的等效的文件)。 这个文件要包含有关于您可能遇到的问题的重要信息, 或指定了您可能使用到的命令的执行顺序。如果 UPDATING 与您这里读到相矛盾,那就先依据 UPDATING 正如先前所述,阅读 UPDATING 并不能替代订阅正确的邮件列表。两都是互补的,并不彼此排斥。 检查 <filename>/etc/make.conf</filename> make.conf 检查 /usr/share/examples/etc/make.conf 以及 /etc/make.conf。 第一个文件包含了一些默认的定义 – 它们中的绝大多数都注释掉了。 为了在重新编译系统时能够使用它们, 请把这些选项加入到 /etc/make.conf。 请注意在 /etc/make.conf 中的任何设置同时也会影响每次运行 make 的结果, 因此设置一些适合自己系统的选项是一个好习惯。 一般的用户通常会从 /usr/share/examples/etc/make.conf 复制 CFLAGSNO_PROFILE 这样的设置到 /etc/make.conf 中并令它们生效。 请考虑其他的一些选项 (例如 COPTFLAGSNOPORTDOCS 等等), 看看是否合用。 更新 <filename>/etc</filename> 里边的文件 /etc 目录包含有除了您的系统启动时执行的脚本外大部分的系统配置信息。 有些脚本随 FreeBSD 的版本而不同。 有些配置文件在天天运行的系统里也是要使用到的。尤其是 /etc/group 偶尔, 作为安装过程的一部分, make installworld 会要求事先创建某些特定的用户或组。 在进行升级时, 它们可能并不存在。 这会给升级造成问题。 有时, make buildworld 会检查它们是否已经存在。 最近就有个这样的例子, 当时新增了 smmsp 用户。 当用户尝试完成安装操作时, 在 &man.mtree.8; 尝试建立 /var/spool/clientmqueue 时失败了。 解决办法是通过使用 选项以构建前 (pre-buildworld) 模式运行 &man.mergemaster.8;。 这表示只对比那些对于成功执行 buildworldinstallworld 起关键作用的文件。 在第一次这样做时, 如果使用的是早期的不支持 mergemaster 版本的话, 使用源码中的新版本即可。 &prompt.root; cd /usr/src/usr.sbin/mergemaster &prompt.root; ./mergemaster.sh -p 如果您是个偏执狂 (paranoid), 您可以检查您的系统看看哪个文件属于您已更名或删除了的那个组。 &prompt.root; find / -group GID -print 将显示所有 GID 组 (可以是组名也可以是数字地组 ID)所有的文件。 改为单用户模式 单用户 模式 您可能想在单用户模式下编译系统。 除了对更快处理事情显然有好处外, 重装系统将触及许多重要的系统文件, 包括所有标准系统二进制文件、库文件、包含 (include) 文件等等。 在正运行的系统 (尤其是在有活跃的用户的时候) 中更改这些文件是自寻烦恼。 多用户模式 另一种模式是在多用户模式下编译系统,然后转换到单用户模式下安装。 如果您喜欢这种方式,只需在建立 (build) 完成后才执行下边的步骤。 您推迟转换到单用户模式下直到您必须 installkernelinstallworld 从运行的系统里,以超级用户方式执行: &prompt.root; shutdown now 这样就会转换到单用户模式。 除此之外, 也可以重启系统, 并在启动菜单处选择 single user(单用户) 选项。 这样系统将以单用户模式启动。 接着, 在 shell 提示符处执行: &prompt.root; fsck -p &prompt.root; mount -u / &prompt.root; mount -a -t ufs &prompt.root; swapon -a 这会检查文件系统,重新将 / 以读/写模式挂接, 参考 /etc/fstab 挂接其它所有的 UFS 文件系统,然后启用交换区。 如果您的 CMOS 时钟是设置为本地时间,而不是 GMT (如果 &man.date.1; 命令输出不能显示正确的时间和地区也确有其事), 您可能也需要执行下边的命令: &prompt.root; adjkerntz -i 这样可以确定您正确的本地时区设置—不这样做, 您以后可能会碰到一些问题。 删除 <filename>/usr/obj</filename> 随着重新构建系统的进行, 编译结果会放到 (默认情况下) /usr/obj 下。 这些目录会映射到 /usr/src 通过删除这个目录, 可以加速 make buildworld 的过程, 并避免相互依赖关系等复杂的问题。 /usr/obj 中的某些文件可能设置了不可改标记 (详情参见 &man.chflags.1;), 需要首先去掉这些标志。 &prompt.root; cd /usr/obj &prompt.root; chflags -R noschg * &prompt.root; rm -rf * - + 重新编译基本系统 保存输出 建议把执行 &man.make.1; 后得到的输出存成一个文件。 如果什么地方出了错,您就会有个错误信息的备份。 尽管这样不能帮您分析哪里出了错, 但如果您把您的问题贴到某个邮件列表里就能帮助其他的人。 这样做最简单的办法是使用 &man.script.1; 命令,同是带上参数指定存放输出的文件名。 您应在重建系统之前立即这样做,然后在过程完成时输入 exit &prompt.root; script /var/tmp/mw.out Script started, output file is /var/tmp/mw.out &prompt.root; make TARGET … compile, compile, compile … &prompt.root; exit Script done, … 如果您这样做,就 不要 把文件存到 /tmp 里边。下次启动时,这个目录就会被清除掉。 存放的最好地方是 /var/tmp (如上个实例)或 root 的主目录。 编译基本系统 您必须在/usr/src目录里边: &prompt.root; cd /usr/src (当然,除非您的源码是在其它地方,真是这样的话更换成那个目录就行了)。 make 使用 &man.make.1; 命令重建系统。这个命令会从 Makefile (描述组成 &os; 的程序应该怎样被重建, 以什么样的顺序建立等等) 里读取指令。 输入的一般命令格式如下: &prompt.root; make -x -DVARIABLE target 这个例子里, 是会传递给 &man.make.1; 的一个选项。查看 &man.make.1; 手册有您可用的选项例子。 传递一个变量给 Makefile。这些变量控制了 Makefile 的行为。这些同 /etc/make.conf 设置的变量一样, 只是提供了另一种设置它们的方法。 &prompt.root; make -DNO_PROFILE target 是另一种指定不被建立 (built) 的先定库 (profiled libraries) 的方式,协同 /etc/make.conf 里的 NO_PROFILE= true # 避免编译性能分析库 一起使用。 目标 (target) 告诉 &man.make.1; 什么该做。每个 Makefile 定义了一定数量不同的目标 (targets), 然后您选择的目标就决定了什么会发生。 有些目标列在 Makefile 里的,但并不意味着您要执行。相反,建立过程 (build process) 利用它们把重建系统的一些必要的步骤分割成几个子步骤。 大部分的时间不需要向 &man.make.1; 传递参数,因此您的命令看起来可能象这样: &prompt.root; make target 此处 target 表示的是若干编译选项。 多数情况下, 第一个 target 都应该是 buildworld 正如名字所暗示的,buildworld/usr/obj 下边建立了一个全新的树, 然后使用另一个 target, installworld 在当前的机器里安装它。 将这些选项分开有两个优点。 首先, 它允许您安全地完成建立 (build), 而不对正在运行的系统的组件产生影响。 构建过程是 自主的 (self hosted)。 因为这样, 您可以安全地在以多用户模式运行的机器里执行 buildworld ,而不用当心不良影响。 但是依然推荐您在单用户模式时运行 installworld 第二,允许您使用 NFS 挂接 (NFS mounts) 升级您网络里的多台计算机。如果您有三台 ABC 想进行升级,在A 执行 make buildworldmake installworld。 然后将 A 上的 /usr/src/usr/obj 通过 NFS 挂接到 BC 上, 接下来, 只需在 BC 上使用 make installworld 来安装构建的结果就可以了。 尽管 world target 仍然存在,强烈建议您不要用它。 运行 &prompt.root; make buildworld 我们提供了一个试验性的功能, 可以在构建过程中为 make 指定 参数, 令其在构建过程中同时启动多个并发的进程。 对于多 CPU 的机器而言, 这样做有助于发挥其性能。 不过, 由于编译过程中的瓶颈主要是在 IO 而不是 CPU 上, 因此它也会对单 CPU 的机器带来好处。 对典型的单 CPU 机器, 可以使用: &prompt.root; make -j4 buildworld 这样, &man.make.1; 会最多同时启动 4 个进程。 从发到邮件列表中的经验看, 这样做能带来最佳的性能。 如果您使用的机器有多颗 CPU, 并且配置了 SMP 的内核, 也可以试试看 6 到 10 的数值, 并观察是否能带来构建性能上的改善。 耗时 rebuilding world timings 联编基本系统所需的时间会受到很多因素的影响, 不过, 较新的机器应该都能在一两个小时之内完成 &os.stable; 源代码的构建, 而无须任何技巧或捷径。 完成 &os.current; 源代码的联编, 则通常需要更长一些的时间。 编译和安装新内核 内核 编译 要充分利用您的新系统,您应该重新编译内核。 这是很有必要的,因为特定的内存结构已经发生了改变,像 &man.ps.1; 和 &man.top.1; 这样的程序会不能工作, 除非内核同源码树的版本是一样的。 最简单、最安全的方式是 build 并安装一个基于 GENERIC 的内核。虽然 GENERIC 可能没有适合您的系统的所有必要的设备, 但它包括了启动您的系统到单用户模式所必需的内容。 这是个不错的检测新系统是否工作正常的测试。在从 GENERIC 启动、核实系统可以工作后, 您就可以建立 (build) 一个基于您的正常内核配置文件的新的内核了。 在 &os; 中, 首先完成 build world 然后再编译新内核非常重要。 如果您想建立一个定制内核,而且已经有了配置文件, 只需象这样使用 KERNCONF=MYKERNEL &prompt.root; cd /usr/src &prompt.root; make buildkernel KERNCONF=MYKERNEL &prompt.root; make installkernel KERNCONF=MYKERNEL 注意,如果您已把 内核安全级别(kern.securelevel) 调高到了 1 以上,而且还设置了 noschg 或相似的标识到了您的内核二进制里边,您可能会发现转换到单用户模式里使用 installkernel 是很有必要的。 如果您没有设置它, 则应该也能毫无问题地在多用户模式执行这两个命令。 请参考 &man.init.8; 以了解更多关于 内核安全级(kern.securelevel) 的信息;查看 &man.chflags.1; 了解更多关于不同文件标识的信息。 重启到单用户模式 单用户模式 您应该单用户模式测试新内核。照处的说明去做。 安装编译好的新系统 如果您正建立一个足以使用 make buildworld 的 &os; 版本,那么您现在应该使用 installworld 来安装新的系统二进制。 执行 &prompt.root; cd /usr/src &prompt.root; make installworld 如果在 make buildworld 的命令行指定了变量,您就必须在 make installworld 命令行里指定同样的变量。 对于其它的选项并不是必需的,如, 就不能同 installworld 一起使用。 举例,您执行了: &prompt.root; make -DNO_PROFILE buildworld 您就必须使用: &prompt.root; make -DNO_PROFILE installworld 来安装结果,否则就要试着安装先定 (profiled) 的在 make buildworld 阶段没有建立 (built) 的二进制文件。 不是由 <command>make installworld</command> 更新的更新文件 重新编译整个系统不会使用新的或改过的配置文件更新某些目录 (尤其像 /etc/var/usr) 更新这些文件最简单的方式就是使用 &man.mergemaster.8;,手工去做也是可以的,只要您愿意。 不管您选择哪一种,一定记得备份 /etc 以防出错。 Tom Rhodes 贡献者: <command>mergemaster</command> mergemaster &man.mergemaster.8; 工具是个 Bourne 脚本,用于检测 /etc/usr/src/etc 源码树里边的配置文件的不同点。 这是保持系统配置文件同源码树里的一起更新的推荐方式。 在提示符里简单地输入 mergemaster 就可以开始,并观看它的开始过程。mergemaster 会建立一个临时的根(root)环境,在 / 下, 放置各种系统配置文件。这些文件然后同当前安装到您系统里的进行比较。 此时,不同的文件会以 &man.diff.1; 格式进行显示,使用 符号标识增加或修改的行, 标识将完全删除的行或将被替换成新行。查看 &man.diff.1; 手册可以得到更多关于 &man.diff.1; 语法和文件不同点怎样显示的信息。 &man.mergemaster.8; 会给您显示每个文件的不同处, 这样您就可以选择是删除新文件 (相对临时文件), 是以未改状态安装临时文件,是以当前安装的文件合并临时文件, 还是再看一次 &man.diff.1; 结果。 选择删除临时文件将使 &man.mergemaster.8; 知道我们希望保留我们当前的文件不改,并删除新的。 并不推荐这个选择,除非您没有更改当前文件的理由。任何时候在 &man.mergemaster.8; 提示符里输入 ?,您就会得到帮助。 如果选择跳过文件,将在其它文件处理完后再次进行。 选择安装未修改临时文件将会使新文件替换当前的。 对大部分未改的文件,这是个最好的选择。 选择合并文件将为您打开一个文本编辑器, 里边是两个文件的内容。您现在就可以一边合并它们, 一边在屏幕里查看,同时从两者中选取部分生成最终文件。 当两个文件一起比较时,l 键会选择左边的内容, r 会选择右边的。最终的输出是由两个部分组成的一个文件, 用它就可以安装了。这个选项通常用于用户修改了设置的文件。 选择再次查看 &man.diff.1; 结果将会在提供给选择之前, 显示文件的不同处,就象 &man.mergemaster.8; 所做的一样。 在 &man.mergemaster.8; 完成了对系统文件的处理后, 您会得到其它的选项。&man.mergemaster.8; 可能会问您是否要重建密码文件, 并在最后提示您是否要删除余下的临时文件。 手动更新 如果想要手工更新,但不要只是从 /usr/src/etc 把文件复制到 /etc 就了事。有些文件是必须先安装的。 这是因为 /usr/src/etc 目录并 不是 想像的那样是 /etc 目录的一个复制。事实上,有些是文件是 /etc 有的,而 /usr/src/etc 里边没有。 如果您使用 &man.mergemaster.8; (作为推荐),您可以向前跳到 - 下一节。 + 下一节。 手工做最简单的方式是安装这些文件到一个新的目录,完成后再来查找不同处。 备份您已有的 <filename>/etc</filename> 虽然,理论上,没有什么会自动访问这个目录, 事情还是做稳操胜当一点。复制已有 /etc 到一个安全的地方,如: &prompt.root; cp -Rp /etc /etc.old 完成递归复制 (译者注:即可以复制目录以下的所有内容), 保留文件的时间、所属等等。 您需要建立一个虚目录 (a dummy set of directories) 来安装新的 /etc 和其它文件。 /var/tmp/root 是个不错的选择, 除此之外,还有一些子目录是需要的。 &prompt.root; mkdir /var/tmp/root &prompt.root; cd /usr/src/etc &prompt.root; make DESTDIR=/var/tmp/root distrib-dirs distribution 这样就建好了需要的目录结构,然后安装文件。在 /var/tmp/root 下建立的大部分子目录是空的, 而且要删除掉。最简单的方式是: &prompt.root; cd /var/tmp/root &prompt.root; find -d . -type d | xargs rmdir 2>/dev/null 这样会删除所有的空目录。(标准的错误信息被重定向到了 /dev/null,以防止关于非空目录的警告。) /var/tmp/root 现在包含了应放在 / 下某个位置的所有文件。 您现在必须仔细检查每一个文件,检测它们与您已有的文件有多大不同。 注意,有些已经安装在 /var/tmp/root 下的文件有个.在开头。在写的时候,像这样唯一的文件是 /var/tmp/root//var/tmp/root/root/ 里 shell 启动文件,尽管可能有其它的(依赖于您什么时候读取这个)。 确信使用 ls -a 可以看到它们。 最简单的方式是使用 &man.diff.1; 去比较两个文件: &prompt.root; diff /etc/shells /var/tmp/root/etc/shells 这会显示出 /etc/shells 文件和新的 /var/tmp/root/etc/shells 文件的不同处。 用这些来决定是合并您已做的变化还是复制您的旧文件过来。 使用日戳 (Time Stamp) 命名新的 Root(根)目录(<filename>/var/tmp/root</filename>),这样您可以轻松地比较两个版本的不同 频繁重建系统意味着必须频繁更新 /etc,而这可能会有点烦琐。 在合并到 /etc 的文件里, 最新更改的您可以做个复制,由此加快这个(指更新)过程。 下边就给出了一个怎样做的主意。 像平常一样建立系统 (Make the world)。当您想更新 /etc 和其它目录里, 给目标目录一个含有当前日期的名字。假如您是 1998 年 2 月 14 日做的,您可以执行下边的: &prompt.root; mkdir /var/tmp/root-19980214 &prompt.root; cd /usr/src/etc &prompt.root; make DESTDIR=/var/tmp/root-19980214 \ distrib-dirs distribution 如上边列出的,从这个目录合并变化。 在您完成后,不要 删除 /var/tmp/root-19980214 目录。 在您下载了最新版的源码并改过后,执行第一步。 这样将得到一个新的目录,可能叫做 /var/tmp/root-19980221 (如果等了一周做的升级)。 您现在能看到两个目录间的不同了---在隔周的时间里使用 &man.diff.1; 建立递归 diff 产生的不同: &prompt.root; cd /var/tmp &prompt.root; diff -r root-19980214 root-19980221 一般情况下,这两种间的不同处比 /var/tmp/root-19980221/etc/etc 之间的不同要小很多。 因为不同点更小,也就更容易把这些变化移到您的 /etc 目录里边。 您现在可以删除早先的两个 /var/tmp/root-* 目录: &prompt.root; rm -rf /var/tmp/root-19980214 每次您需要合并这些变化到 /etc 里,就重复这个流程。 您可以使用 &man.date.1; 自动产生目录的名称: &prompt.root; mkdir /var/tmp/root-`date "+%Y%m%d"` - + 重启 现在完成了。在您检查所有内容都放置正确后, 您可以重启系统了。只是简单的 &man.shutdown.8; 可以这样做: &prompt.root; shutdown -r now 结束 恭喜!您现在成功升级了您的 &os; 系统。 如果还有轻微的错误,可以轻易地重建系统的选定部分。 例如,在部分升级或合并 /etc 时,您不小心删除了 /etc/magic,&man.file.1; 命令就会停止工作。这种情况下,执行下边进行修复: &prompt.root; cd /usr/src/usr.bin/file &prompt.root; make all install 问题 每个变化您都须要重建系统吗? 这个不好说,因为要看变化的情况。如,如果您刚运行了 CVSup,并得到下边更新的文件: src/games/cribbage/instr.c src/games/sail/pl_main.c src/release/sysinstall/config.c src/release/sysinstall/media.c src/share/mk/bsd.port.mk 这就不必重建整个系统。您只需到相关的子目录里执行 make all install,仅此而已。 但是,如果有重大变化,如 src/lib/libc/stdlib, 那么您就要重建系统或至少静态连接的那些部分 (除了您增加的部分都是静态连接的)。 在这天后,就是您的事了。要是说每两个星期重建一下系统的话, 您可能会高兴。或者您可能只想重做改变过的部分, 确信您能找出所有依赖关系。 当然,所有这些依赖于您想升级的频率,和您是否想跟踪 &os.stable; 或 &os.current;。 我的编译失败,并伴随有许多 11 (或其它的数字信息) 号错误。是怎么回事呀? 信号 11 这个通常表示硬件错误。 (重)建系统是个强压测试系统硬件的有效地方式, 并且常常产生内存错误。 这些正好表示它们自已做为编译器离奇地死于收到的奇怪信息。 一个确信的指示器是如果重新开始 make,并且整个过程中会死在不同的点上。 对于这种情况,您没有什么可做的,除了更换机器里的部件,看是哪一个坏了。 我完成后可以删除 /usr/obj 吗? 简短地说,可以。 /usr/obj 包含了所有在编译阶段生成的目标文件。通常, 在 make buildworld 过程中第一步之一就是删除这个目录重新开始。 这种情况下,在您完成后,保留 /usr/obj 没有多大意义,还可释放一大堆磁盘空间(通常在 340 MB 左右)。 只是,如果您清楚您在干什么,您可以让 make buildworld 跳过这一步。 这会让后继的 build 执行得更快,因为大部分的源码都不必再进行编译了。 这个的另一面就在于敏感的依赖问题可以潜在, 并以奇怪的方式引起 build 的失败。这在 &os; 邮件列表里经常引起沸腾, 当有人抱怨他们 build 失败时,并没意识到这是因为自已是想抄近路 (意思是说少了些必要的步骤)。 中断的 build 可以被恢复吗? 依赖于您在您找到问题之前整个过程进行了多远。 一般而言 (当然这并不是硬性规定), make buildworld 的过程中将会首先构建新版的基本构建工具 (例如 &man.gcc.1;, 以及 &man.make.1;) 和系统库。 随后会安装这些工具和库。 这些新版本的工具和库在随后将被用于重新编译和连接它们本身。 整个系统 (现在包括了常规的用户程序, 例如 &man.ls.1; 或 &man.grep.1;) 会同新版的系统文件一起被重新构建。 如果您正处于最后一个阶段, 并且了解它 (因为您已经看过了所保存的输出) 则可以 (相当安全地) 做: … 问题修复 … &prompt.root; cd /usr/src &prompt.root; make -DNO_CLEAN all 这样就不会取消先前的 make buildworld 所做的工作了。 make buildworld的输出中如果看到如下信息: -------------------------------------------------------------- Building everything.. -------------------------------------------------------------- 出现在 make buildworld 的输出中, 则这样做应该不会有什么问题。 如果没有看到这样的信息, 或者您不确定, 则从头开始构建将是万无一失的做法。 我怎样加快建立系统的速度? 以单用户模式运行 /usr/src/usr/obj 目录放到不同磁盘里的独立文件系统里。如果可能,这些磁盘在不同的磁盘控制器里。 更好的,是把这些文件系统放置到多个使用 &man.ccd.4; (连接磁盘驱动器--concatenated disk driver)设备的磁盘里。 关掉 profiling (在 /etc/make.conf 里设置 NO_PROFILE=true)。您差不多用不了它。 /etc/make.conf 里也为 CFLAGS 设置上 。 最佳优化 会更慢,而且 之间的优化差别基本上可以忽略。 让编译器使用管道而不用临时文件进行通信, 这样可以减少磁盘存取 (以内存作为代价)。 传递 选项给 &man.make.1; 以便并发运行多个进程。 这样就不会考虑您的是否是单个或多个处理器机器。 存放 /usr/src 的文件系统可以使用 选项来挂接 (或重新挂接)。 这样会防止文件系统记录文件的存取时间。 您可能并不需要这些信息。 &prompt.root; mount -u -o noatime /usr/src 这个例子里假定 /usr/src 是在它自已的文件系统里。如果不是 (例如假设它是 /usr 的部分),那么您就需要那个文件系统挂接点, 而不是 /usr/src 存放 /usr/obj 的文件系统可以使用 选项被挂接 (或重新挂接)。 这样做将启用异步写盘。 换句话说, 对应用程序而言写会立即完成, 而数据则延迟几秒才会写到盘里。 这样做能够成批地写下数据, 从而极大地改善性能。 注意, 这个选项会使您的文件系统变得脆弱。 使用这个选项会提高在电源断掉或机器非正常重启时, 文件系统进入不可恢复状态的概率。 如果在这个文件系统里 /usr/obj 是很关键的,这不是问题。如果您有其它有价值的数据在同一个文件系统, 那么在您使用这个选项这前,确认备份一下。 &prompt.root; mount -u -o async /usr/obj 同上,如果 /usr/obj 不在自已的文件系统里,使用相关挂接点的名字把它从例子里边替换掉。 如果出现了错误我该怎么办? 绝对确信您的环境没有先前 build 留下的残余。这点够简单。 &prompt.root; chflags -R noschg /usr/obj/usr &prompt.root; rm -rf /usr/obj/usr &prompt.root; cd /usr/src &prompt.root; make cleandir &prompt.root; make cleandir 不错,make cleandir 真的要执行两次。 然后重新开始整个过程,使用 make buildworld 开始。 如果您还有问题,就把错误和 uname -a 的输出发送到 &a.questions; 邮件列表。准备回答其它关于您的设置的问题! Mike Meyer 贡献者 跟踪多台机器 NFS 安装多台机器 如果您有多台机器想跟踪同样的源码树, 那么让它们都下载源码并重建所有东西,看起有点浪费资源: 磁盘空间、网络带宽以及 CPU 周期。 解决的办法是让一台机器处理大部分的工作,而其它的机器通过 NFS 挂接 (mount) 这些工作。这部分列举了一种这样做的方法。 准备 首先,确定一批机器,运行的二进制代码是同一套---我们称作 构建集群 (build set)。 每台机器可以使用不同的定制内核, 但它们运行的是相同的用户区二进制文件(userland binaries)。 从这批机器中选择一台机器做为 构建机器(build machine)。 这将是用于构建(build)系统和内核的机器。想像一下,它应该是一台快速的机器, 有足够的空余的 CPU 来执行make buildworld。 您也想要选一台机器做为 测试机器(test machine), 这个将用于软件的更新生成产品之前对他们进行测试。这个 必须 是一台您能提供的平时也可使用的机器。 它可以是构建机器,但没这个必要。 在这个构建集群里的所有机器需要从同一台机器、 同一个点上挂接 /usr/obj/usr/src。理想地, 它们在构建机器上的两个不同的驱动器里, 但是在那台机器上可以进行 NFS 挂接。如果您有多个构建集群/usr/src 应该在某个构建机器上, 而在其它机器上进行 NFS 挂接。 最后,确认构建集群里所有机器上的 /etc/make.conf/etc/src.conf构建机器里的相同。 这意味着构建机器必须构建部分基本系统用于 构建集群里所有机器的安装。同样, 每台构建机器要有它自已的内核名字,使用 /etc/make.conf 里的 KERNCONF 进行设置,并且每台构建机器应该把它们列在 KERNCONF 里,同时把自已的内核列在最前。 构建机器/usr/src/sys/arch/conf 里一定要有每台机器的内核配置文件,如果它想构建它们的内核的话。 基本系统 既然所有的妥当了,就准备构建所有的东西。如中描述的一样在构建机器上构建内核和系统, 但是什么也不安装。在构建结束后,转到测试机器上, 安装您刚构建的内核。如果这台机器通过 NFS 挂接了 /usr/src/usr/obj, 在您重启到单用户模式里,您需要启动网络然后挂接他们。 最简单的方式是启动到多用户模式下,然后执行 shutdown now 转到单用户模式。一旦进入,您就可以安装新的内核和系统,并执行 mergemaster,就像平常一样。完成后, 重启返回到一般多用户模式操作这台机器。 在您确信所有在 测试机里都工作正常后, 就使用相同的过程在 构建集群里的其它机器里安装新的软件。 Ports 类似的想法是使用 ports 树。 第一个关键的步骤是从同一台计算机上挂接 /usr/ports构建集群 里的全部计算机。 然后正确设置 /etc/make.conf 共享 distfiles。您应把 DISTDIR 设置到一个共享的目录里, 那里可以被任何一个 root 用户写入, 并且是由您的 NFS 挂接映射的。 设置每一台机器的 WRKDIRPREFIX 到一个本地构建 (build) 目录。最后,如果您要构建和发布包 (packages),那么您应该设置 PACKAGES 到一个类似于 DISTDIR 的目录。 diff --git a/zh_CN.GB2312/books/handbook/desktop/chapter.sgml b/zh_CN.GB2312/books/handbook/desktop/chapter.sgml index 8d6bed813d..4a0a753327 100644 --- a/zh_CN.GB2312/books/handbook/desktop/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/desktop/chapter.sgml @@ -1,1040 +1,1042 @@ Christophe Juniet Contributed by 桌面应用 概述 FreeBSD 可以运行种类繁多的桌面应用程序, 这包括像浏览器和字处理这样的软件。 绝大多数这样的程序都可以通过 package 来安装, 或者从 Ports Collection 自动地构建。 许多新用户希望能够在它们的系统中找到这样的应用程序。 这一章将向您展示如何轻松地使用 package 或者 Ports Collection 中安装这样的软件。 需要注意的是从 ports 安装意味着要编译源码。 根据编译的 ports 和电脑速度的不同, 这可能需要花费相当长的时间。 若是您觉得编译源码太过耗时的话, 绝大多数 ports 也有预编译的版本可供安装。 因为 FreeBSD 提供的二进制兼容 Linux 的特性, 许多原本为 Linux 开发的程序都可以直接用在您的桌面。 在安装任何的 Linux 应用程序之前, 强烈的推荐您阅读 。 当您在寻找特定的 ports 时, 可以使用 &man.whereis.1;。 一般来说, 许多利用 Linux 二进制兼容特性的 ports 都以linux-开头。 在下面的介绍中,都假设安装 Linux 应用程序前已经开启了 Linux 二进制兼容功能。 本章涵盖以下种类应用程序: - 浏览器 (例如 Mozilla、 + 浏览器 (例如 FirefoxOpera、 - FirefoxKonqueror) 办公、图象处理 (例如 KOfficeAbiWordGIMPOpenOffice.org) 文档查看 (例如 &acrobat.reader;gvXpdfGQview) 财务 (例如 GnuCashGnumericAbacus) 阅读这章之前,您应该: 知道如何安装额外的第三方软件()。 知道如何安装 Linux 软件()。 想要获得更多的有关多媒体环境的信息,请阅读 。如果您想要建立和使用电子邮件, 请参考 浏览器 浏览器 web FreeBSD并没有预先安装特定的浏览器。然而,在 ports 的目录 www 有许多浏览器可以安装。如果您没有时间一一编译它们 (有些时候这可能需要花费相当长的时间) 大部分都有 package 可用。 KDEGNOME 已经提供 HTML 浏览器。 请参考得到更多完整的有关设定这些桌面环境的信息。 如果您要找小型的浏览器, 可以试试看 www/dillowww/linkswww/w3m 这一节涉及如下程序: 程序名称 资源需求 安装时间 主要依赖 - Mozilla - - 大量时间和空间 + Firefox + 中等 + Gtk+ Opera 轻松 同时有可用的 FreeBSD 和 Linux 版本。 Linux 版本需要使用 Linux 二进制兼容模块和 linux-openmotif Firefox 中等 Gtk+ Konqueror 中等 需要 KDE - - Mozilla - - Mozilla - - - Mozilla 是一个完全移植到 FreeBSD - 上的现代化的、 稳定的浏览器。 它拥有非常合乎标准的 HTML 支持, - 它也能处理邮件和阅读新闻组。 - 假如您打算做一个自己的主页的话,它甚至提供一个 HTML 编辑器。 - &netscape; 的使用者可能觉得它和 - Communicator 非常相似, - 两者有些部分实际上是相通的。 - - 在 CPU 速度低于 233MHz 或者内存少于 64MB - 的老式电脑上,Mozilla - 会占用相当多资源而难以使用。您也许可以试试 - Opera 浏览器,本章稍后将会介绍它。 - - 也许基于某种原因,您不能或者不想编译 - Mozilla,FreeBSD GNOME 团队已经为您制作好了 - package。只需要通过网络安装它: - - &prompt.root; pkg_add -r mozilla - - 如果没 package 可用,而您又有足够的时间和磁盘空间,您可以获取 - Mozilla 的源码来编译并安装它到您的系统上。 - 执行以下指令既可: - - &prompt.root; cd /usr/ports/www/mozilla -&prompt.root; make install clean - - Mozilla 需要 root - 权限执行 chrom 注册来确定正确的初始化。另外, - 如果您想要一些额外的插件比如象 mouse gestures,您也必须以 - root 权限执行 Mozilla - 以便正确的安装。 - - 一旦您完成了 Mozilla 安装,您就再也不需要 - root 权限了。您可以用如下方式执行 - Mozilla - - &prompt.user; mozilla - - 也可以用如下方式直接运行电子邮件和新闻阅读器: - - &prompt.user; mozilla -mail - - Firefox Firefox - Firefox 是基于 Mozilla - 代码系的下一代浏览器。 Mozilla - 是一个完整的应用程序套件, 包含了浏览器、 邮件客户端、 - 聊天客户端等等。 而 Firefox - 则只是一个浏览器, 这使得它体积更小并且执行速度更快。 + Firefox 是一个现代, 自由, + 开放源代码稳定的浏览器, 并完全移植到了 &os; 上: + 它的特性包括有一个非常标准的 HTML 显示引擎, + 标签式浏览, 弹出窗口阻止, 扩展插件, 改进的安全性, 等等。 + Firefox 是基于 + Mozilla 的代码。 您可以通过输入下面的命令来安装预编译的包: &prompt.root; pkg_add -r firefox - 如果您喜欢从源代码编译, 则可以使用 Ports - 套件来完成这项工作: + 这将会安装 Firefox 2.X, + 如果你希望运行 Firefox 3.X, + 则执行如下的命令: + + &prompt.root; pkg_add -r firefox3 + + 如果你希望从源代码编译的话, + 可以通过 Ports Collection 安装: &prompt.root; cd /usr/ports/www/firefox &prompt.root; make install clean + + For Firefox 3.X, in the + previous command replace firefox with + firefox3. - Firefox、 Mozilla 与 &java; 插件 + Firefox 与 &java; 插件 在这一节和下一节中, - 我们均假定您已经安装了 Firefox 或 - Mozilla + 我们均假定您已经安装了 Firefox &os; 基金会拥有来自 Sun Microsystems 的关于发布针对 &os; 的预编译版本的 Java 运行环境 (&jre;) 和 Java 开发包 (&jdk;) 的授权。 用于 &os; 的预编译版本可以在 &os; 基金会 网站上找到。 - 要为 Firefox 或 - Mozilla 添加 &java; 支持, - 您必须首先安装 要为 Firefox + 添加 &java; 支持,您必须首先安装 java/javavmwrapper port。 接下来, 从 下载 Diablo &jre; 软件包, 并使用 &man.pkg.add.1; 来安装它。 启动浏览器, 并在地址栏中输入 about:plugins 然后按 Enter。 浏览器将给出一个页面, 其中会显示已经安装的插件, 您应在这个列表中找到 &java; 插件。 如果不是这样的话, 则需要以 root 身份执行下列命令: &prompt.root; ln -s /usr/local/diablo-jre1.6.0/plugin/i386/ns7/libjavaplugin_oji.so \ /usr/local/lib/browser_plugins/ 然后重新启动浏览器。 - Firefox、 Mozilla 与 ¯omedia; &flash; 插件 + Firefox 与 ¯omedia; &flash; 插件 + + Flash + ¯omedia; &flash; 插件并没有直接提供其 &os; 版本。 不过, 我们有一个软件层 (wrapper) 可以用来运行 Linux 版本的插件。 这个 wrapper 也支持 &adobe; &acrobat;、 RealPlayer 和很多其他插件。 + + 以下的章节涵盖了在近期 -STABLE 分支, &os; 7.1-RELEASE + 及以上的版本安装 &flash; 9.X。 如果你正在使用一个旧版本的 &os; + 或者遇到了问题, 你应该安装 + www/linux-flashplugin7 + 并跳过 &man.linprocfs.5; 的部分。 + + 应安装 www/nspluginwrapper port, 这个 port 需要依赖一个很大的 port emulators/linux_base 下一步是安装 www/linux-flashplugin7 port。 + role="package">www/linux-flashplugin9 port。 一旦装好了这个插件,需要用户运行一下 nspluginwrapper 命令: &prompt.user; nspluginwrapper -v -a -i + 如果希望播放 &flash; 动画的话,&linux; 的进程文件系统, + &man.linprocfs.5; 必须挂载于 + /usr/compat/linux/proc。 + 可以通过以下的命令实现: + + &prompt.user; mount -t linprocfs linproc /usr/compat/linux/proc + + 这也可以在机器启动时自动挂载, 把以下这行加入 + /etc/fstab + + linproc /usr/compat/linux/proc linprocfs rw 0 0 + 然后就可以打开浏览器, 并在地址栏中输入 about:plugins 然后按下 Enter。 这将显示目前可用的插件列表。 + + Firefox and Swfdec &flash; Plugin + + Swfdec 是一个用以解码和渲染 &flash; 动画的库。 + Swfdec-Mozilla 是一个使用了 Swfdec 库让 Firefox + 能播放 SWF 文件的插件。它目前仍处于开发状态。 + + 如果你不能或者不想编译安装,可以通过网络安装二进制包: + + &prompt.root; pkg_add -r swfdec-plugin + + 如果二进制包还不可用,你可以通过 Ports Collection 编译安装: + + &prompt.root; cd /usr/ports/www/swfdec-plugin +&prompt.root; make install clean + + 然后重启你的浏览器使得这个插件生效。 + + Opera Opera Opera 是一个功能齐全, 并符合标准的浏览器。 它还提供了内建的邮件和新闻阅读器、 IRC 客户端, RSS/Atom feed 阅读器以及更多功能。 除此之外, Opera 是一个比较轻量的浏览器, 其速度很快。 它提供了两种不同的版本: native FreeBSD 版本, 以及通过 Linux 模拟运行的版本。 要使用 Opera 的 FreeBSD 版本来浏览网页,安装以下的 package: &prompt.root; pkg_add -r opera 有些 FTP 站点没有所有版本的 package, 但仍然可以通过 Ports 套件来安装 Opera &prompt.root; cd /usr/ports/www/opera &prompt.root; make install clean 要安装 Linux 版本的 Opera,将上面例子中的 opera 替换为 linux-opera。Linux 版本在某些情况下非常有用,象是使用只有 Linux 版本的插件,例如 Adobe &acrobat.reader;。就其它方面来说, FreeBSD 和 Linux 版本的功能是完全一样的。 Konqueror Konqueror KonquerorKDE 的一部分,不过也可以通过安装 x11/kdebase3 在非 KDE 环境下使用。 Konqueror 不止是一个浏览器, 也是一个文件管理器和多媒体播放器。 也有种类丰富的插件能够配合 Konqueror 一起使用, 您可以通过 misc/konq-plugins 来安装它们。 Konqueror 也支持 &flash;; 关于如何获得用于 Konqueror&flash; 支持的 How To 文档 可以在 找到。 办公、图象处理 当需要进行办公或者进行图象处理时, 新用户通常都会找一些好用的办公套件或者字处理软件。 尽管目前有一些 桌面环境, 如 KDE 已经提供了办公套件, 但目前这还没有一定之规。 无论您使用那种桌面环境, FreeBSD 都能提供您需要的软件。 这节涉及如下程序: 软件名称 资源需求 安装时间 主要依赖 KOffice KDE AbiWord Gtk+GNOME The Gimp Gtk+ OpenOffice.org &jdk; 1.4Mozilla KOffice KOffice 办公套件 KOffice KDE 社区提供了一套办公套件, 它能用在桌面环境。它包含四个标准的组件,这些组件可以在其它办公套件中找到。 KWord 是字处理程序、 KSpread 是电子表格程序、 KPresenter 是演示文档制作管理程序、 Kontour是矢量绘图软件。 安装最新的 KOffice 之前,先确定您是否安装了最新版的 KDE 使用 package 来安装 KOffice,安装细节如下: &prompt.root; pkg_add -r koffice 如果没有可用的 package,您可以使用 Ports Collection 安装。 安装 KDE3KOffice 版本,如下: &prompt.root; cd /usr/ports/editors/koffice-kde3 &prompt.root; make install clean AbiWord AbiWord AbiWord 是一个免费的字处理程序,它看起来和 µsoft; Word 的感觉很相似。 它适合用来打印文件、信函、报告、备忘录等等, 它非常快且包含许多特性,并且非常容易使用。 AbiWord 可以导入或输出很多文件格式, 包括一些象 µsoft; .doc 这类专有格式的文件。 AbiWord 也有 package 的安装方式。您可以用以下方法安装: &prompt.root; pkg_add -r abiword 如果没有可用的 package,它也可以从 Ports Collection 编译。ports collection 应该是最新的。它的安装方式如下: &prompt.root; cd /usr/ports/editors/abiword &prompt.root; make install clean GIMP GIMP 对图象的编辑或者加工, GIMP 是一个非常精通图象处理的软件。 它可以被用来当作简单的绘图程序或者一个专业的照片处理套件。 它支持大量的插件和具有脚本界面的特性。 GIMP 可以读写众多的文件格式, 支持扫描仪和手写板。 您可以用下列命令安装: &prompt.root; pkg_add -r gimp 如果您在 FTP 站点没有找到这个 package,您也可以使用 Ports Collection 的方法安装。ports 的 graphics 目录也包含有 Gimp 手册。 以下是安装它们的方法: &prompt.root; cd /usr/ports/graphics/gimp &prompt.root; make install clean &prompt.root; cd /usr/ports/graphics/gimp-manual-pdf &prompt.root; make install clean Ports 中的 graphics 目录也有开发中的 GIMP 版本 graphics/gimp-devel。 HTML 版本的 Gimp 手册 可以在 graphics/gimp-manual-html 找到。 OpenOffice.org OpenOffice.org 办公套件 OpenOffice.org OpenOffice.org 包括一套完整的办公套件: 字处理程序、 电子表格程序、 演示文档管理程序和绘图程序。 它和其它的办公套件的特征非常相似,它可以导入输出不同的流行的文件格式。 它支持许多种语言 — 国际化已经渗透到了其界面、 拼写检查和字典等各个层面。 OpenOffice.org 的字处理程序使用 XML 文件格式使它增加了可移植性和灵活性。 电子表格程序支持宏语言和使用外来的数据库界面。 OpenOffice.org 已经可以平稳的运行在 &windows;、&solaris;、Linux、FreeBSD 和 &macos; X 等各种操作系统下。 更多的有关 OpenOffice.org 的信息可以在 OpenOffice.org 网页 找到。 对于特定的 FreeBSD 版本的信息,您可以在直接在 FreeBSD OpenOffice 移植团队的页面下载。 安装 OpenOffice.org 方法如下: &prompt.root; pkg_add -r openoffice.org 如果您正在使用 &os; 的 -RELEASE 版本, 一般来说这样做是没问题的。 如果不是这样, 您就可能需要看一看 &os; OpenOffice.org 移植小组的网站, 并使用 &man.pkg.add.1; 从那里下载并安装合适的软件包。 最新的发布版本和开发版本都可以在那里找到。 装好 package 之后, 您只需输入下面的命令就能运行 OpenOffice.org 了: &prompt.user; openoffice.org 在第一次运行时, 将询问您一些问题, 并在您的主目录中建立一个 .openoffice.org2 目录。 如果没有可用的 OpenOffice.org package,您仍旧可以选择编译 port。然而, 您必须记住它的要求以及大量的磁盘空间和相当长的时间编译。 &prompt.root; cd /usr/ports/editors/openoffice.org-2 &prompt.root; make install clean 如果希望联编一套进行过本地化的版本, 将前述命令行改为: &prompt.root; make LOCALIZED_LANG=your_language install clean 您需要将 your_language 改为正确的 ISO-代码。 所支持的语言代码可以在 files/Makefile.localized 文件中找到, 这个文件位于 port 的目录。 一旦完成上述操作, 就可以通过下面的命令来运行 OpenOffice.org 了: &prompt.user; openoffice.org 文档查看器 &unix; 系统出现以来, 一些新的文档格式开始流行起来; 它们所需要的标准查看器可能不一定在系统内。 本节中, 我们将了解如何安装它们。 这节涵盖如下应用程序: 软件名称 资源需求 安装时间 主要依赖 &acrobat.reader; Linux二进制兼容 gv Xaw3d Xpdf FreeType GQview Gtk+GNOME &acrobat.reader; Acrobat Reader PDF 查看器 现在许多文档都用 PDF 格式, 根据轻便小巧文档格式的定义。一个被建议使用的查看器是 &acrobat.reader;,由 Adobe 所发行的 Linux 版本。因为 FreeBSD 能够运行 Linux 二进制文件, 所以它也可以用在 FreeBSD 中。 要从 Ports collection 安装 &acrobat.reader; 7, 只需: &prompt.root; cd /usr/ports/print/acroread7 &prompt.root; make install clean 由于授权的限制, 我们不提供预编译的版本。 gv gv PDF 查看器 PostScript 查看器 gv 是 &postscript; 和 PDF 文件格式查看器。它源自 ghostview 因为使用 Xaw3d 函数库让它看起来更美观。 它很快而且界面很干净。gv 有很多特性比如象纸张大小、刻度或者抗锯齿。 大部分操作都可以只用键盘或鼠标完成。 安装 gv package,如下: &prompt.root; pkg_add -r gv 如果您无法获取预编译的包, 则可以使用 Ports collection: &prompt.root; cd /usr/ports/print/gv &prompt.root; make install clean Xpdf Xpdf PDF 查看器 如果您想要一个小型的 FreeBSD PDF 查看器, Xpdf 是一个小巧并且高效的查看器。 它只需要很少的资源而且非常稳定。它使用标准的 X 字体并且不需要 &motif; 或者其它的 X 工具包。 安装 Xpdf package,使用如下命令: &prompt.root; pkg_add -r xpdf 如果 package 不可用或者您宁愿使用 Ports Collection,如下: &prompt.root; cd /usr/ports/graphics/xpdf &prompt.root; make install clean 一旦安装完成,您就可以启动 Xpdf 并且使用鼠标右键来使用菜单。 GQview GQview GQview 是一个图片管理器。 您可以单击鼠标来观看一个文件、开启一个外部编辑器、 使用预览和更多的功能。它也有幻灯片播放模式和一些基本的文件操作。 您可以管理采集的图片并且很容易找到重复的。 GQview 可以全屏幕观看并且支持国际化。 如果您想要安装 GQview package,如下: &prompt.root; pkg_add -r gqview 如果您没有可用的 package 或者您宁愿使用 Ports Collection,如下: &prompt.root; cd /usr/ports/graphics/gqview &prompt.root; make install clean 财务 假如,基于任何的理由,您想要在 FreeBSD Desktop 管理您个人的财政,有一些强大并且易于使用的软件可以被您选择安装。 它们中的一些与流行的文件格式兼容象 QuickenExcel 文件。 本节涵盖如下程序: 软件名称 资源需求 安装时间 主要依赖 GnuCash GNOME Gnumeric GNOME Abacus Tcl/Tk KMyMoney KDE GnuCash GnuCash GnuCashGNOME 的一部分,GNOME 致力于为最终用户提供用户友好且功能强大的软件。使用 GnuCash,您可以关注您的收入和开支、您的银行帐户, 或者您的股票。它的界面特性看起来非常的专业。 GnuCash 提供一个智能化的注册、帐户分级系统、 很多键盘快捷方式和自动完成方式。它能分开一个单个的处理到几个详细的部分。 GnuCash 能导入和合并 Quicken QIF 文件格式。 它也支持大部分的国际日期和流行的格式。 在您的系统中安装 GnuCash 所需的命令如下: &prompt.root; pkg_add -r gnucash 如果 package 不可用,您可以使用 Ports Collection 安装: &prompt.root; cd /usr/ports/finance/gnucash &prompt.root; make install clean Gnumeric Gnumeric 电子表格 Gnumeric Gnumeric 是一个电子表格程序, GNOME 桌面环境的一部分。 它以通过元素格式和许多片断的自动填充系统来方便的自动猜测用户输入而著称。 它能导入一些流行的文件格式,比如象 ExcelLotus 1-2-3Quattro ProGnumeric 凭借 math/guppi 支持图表。 它有大量的嵌入函数和允许所有通常比如象、数字、货币、日期、 时间等等的一些单元格式。 以 package 方式安装 Gnumeric 的方法如下: &prompt.root; pkg_add -r gnumeric 如果 package 不可用,您可以使用 Ports Collection 安装: &prompt.root; cd /usr/ports/math/gnumeric &prompt.root; make install clean Abacus Abacus spreadsheet Abacus Abacus 是一个小巧易用的电子表格程序。 它包含许多嵌入函数在一些领域如统计学、财务和数学方面很有帮助。 它能导入和输出 Excel 文件格式。 Abacus 可以产生 &postscript; 输出。 以 package 的方式安装 Abacus 的方法如下: &prompt.root; pkg_add -r abacus 如果 package 不可用,您可以使用 Ports Collection 安装: &prompt.root; cd /usr/ports/deskutils/abacus &prompt.root; make install clean KMyMoney KMyMoney spreadsheet KMyMoney KMyMoney 是一个 KDE环境下的个人财务管理软件。 KMyMoney 旨在提供并融合各种商业财务管理软件所有的重要特性。 它也同样注重易用性和特有的复式记帐功能。 KMyMoney 能从标准的 Quicken Interchange Format (QIF) 文件导入数据, 追踪投资,处理多种货币并能提供一个财务报告。 另有可用的插件支持导入 OFX 格式的数据。 以 package 的方式安装 KMyMoney 的方法如下: &prompt.root; pkg_add -r kmymoney2 如果 package 不可用,您可以使用 Ports Collection 安装: &prompt.root; cd /usr/ports/finance/kmymoney2 &prompt.root; make install clean 总结 尽管 FreeBSD 由于其高性能和可靠性而获得了许多 ISP 的信赖, 但它也完全可以用于桌面环境。 拥有数以千计的 packagesports 能够帮您迅速建立完美的桌面环境。 下面是本章涉及到的所有的软件的简要回顾: 软件名称 Package 名称 Ports 名称 - - Mozilla - mozilla - www/mozilla - - Opera opera www/opera Firefox firefox www/firefox KOffice koffice-kde3 editors/koffice-kde3 AbiWord abiword editors/abiword The GIMP gimp graphics/gimp OpenOffice.org openoffice editors/openoffice-1.1 &acrobat.reader; acroread print/acroread7 gv gv print/gv Xpdf xpdf graphics/xpdf GQview gqview graphics/gqview GnuCash gnucash finance/gnucash Gnumeric gnumeric math/gnumeric Abacus abacus deskutils/abacus + + + KMyMoney + kmymoney2 + finance/kmymoney2 + + diff --git a/zh_CN.GB2312/books/handbook/disks/chapter.sgml b/zh_CN.GB2312/books/handbook/disks/chapter.sgml index e99862ccaf..8636f5742f 100644 --- a/zh_CN.GB2312/books/handbook/disks/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/disks/chapter.sgml @@ -1,3670 +1,3675 @@ 存储 概述 这章介绍了 FreeBSD 中磁盘的使用方法。包括内存盘, 网络附属磁盘和标准的 SCSI/IDE 存储设备,以及使用 USB 的设备。 读完这章,您将了解到: FreeBSD 中用来描述硬盘上数据组织的术语 (partitions and slices)。 如何在您的系统上增加硬盘。 如何配置 &os; 来使用 USB 存储设备。 如何设置虚拟文件系统,例如内存磁盘。 如何使用配额来限制磁盘空间的使用。 如何增加磁盘安全来预防功击。 如何刻录 CD 和 DVD 。 用于备份的多种存储媒介。 如何在 FreeBSD 上使用备份程序。 如何备份到软磁盘。 文件系统快照是什么, 以及如何有效地使用它们。 在读这章之前,您应该: 知道怎样去配置和安装新的 FreeBSD 内核 (). 设备命名 下面是在 FreeBSD 上被支持的物理存储设备和它们被分配的设备名。 物理磁盘命名规则 驱动器类型 驱动设备命名 IDE 硬盘驱动器 ad IDE CDROM 驱动器 acd SCSI 硬盘以及 USB 大容量存储设备 da SCSI CDROM 驱动器 cd 各类非标准 CDROM 驱动器 用于 Mitsumi CD-ROM 的 mcd 以及用于 Sony CD-ROM 驱动器的 scd Floppy drives fd SCSI tape drives sa IDE tape drives ast Flash drives fla for &diskonchip; Flash device RAID drives aacd for &adaptec; AdvancedRAID, mlxd and mlyd for &mylex;, amrd for AMI &megaraid;, idad for Compaq Smart RAID, twed for &tm.3ware; RAID.
David O'Brien Originally contributed by 添加磁盘 磁盘 添加 假设我们要给一台只有一个磁盘的机器增加一个新的 SCSI 磁盘。首先 需要关掉计算机,然后按操作规程来安装驱动器,控制器和驱动程序。由于 各厂家生产的产品各不相同,具体的安装细节不在此文档介绍之内。 root 用户登录。安装完驱动后,检查一下 /var/run/dmesg.boot 有没有找到新的磁盘。在我们 的例子中新增加的磁盘就是 da1,我们从 /1 挂上它。 (如果您正添加 IDE 驱动器, 则设备名应该是 ad1)。 partitions slices fdisk 因为 FreeBSD 运行在 IBM-PC 兼容机上,它必须遵循 PC BIOS 分区规范。 这与传统的 BSD 分区是不同的。一个 PC 的磁盘最高只能有四个 BIOS 主分区。如果磁盘只安装 FreeBSD 您可以使用 dedicated 模式。另外, FreeBSD 必须安装在 PC BIOS 支持的分区内。FreeBSD 把分区叫作 slices 这可能会把人搞糊涂。您也可以在只安装 FreeBSD 的磁盘上使用 slices,也可以在安装有其它操作系统的磁盘上使用 slices。这不会影响其它操作系统的 fdisk 分区工具。 在 slice 方式表示下,驱动器被添加到 /dev/da1s1e。 可以读作:SCSI 磁盘,编号为 1 (第二个SCSI 磁盘), slice 1 (PC BIOS 分区 1), 的 BSD 分区 e 。在有些例子中,也可以简化为 /dev/da1e 由于 &man.bsdlabel.8; 使用 32-位 的整数来表示扇区号, 因此在多数情况下它的表现力限于每个磁盘 2^32-1 个扇区或 2TB。 &man.fdisk.8; 格式允许的起始扇区号不能高于 2^32-1 而分区长度也不能大于 2^32-1, 通常情况下这限制了分区大小最大为 2TB 而磁盘大小则是 4TB。 &man.sunlabel.8; 格式的限制是每个分区 2^32-1 个扇区, 但允许 8 个分区因此最大支持 16TB 的磁盘。 要使用更大的分区, 则应使用 &man.gpt.8;。 使用 &man.sysinstall.8; sysinstall adding disks su 使用 <application>Sysinstall</application> 您可以使用 sysinstall 命令的菜单来分区和标记一个新的磁盘。 这一操作需要有 root 权限, 您可以直接使用 root 账户登录或者使用 su 命令来切换到 root 用户。运行 sysinstall ,然后选择 Configure 菜单。在 FreeBSD Configuration Menu 下,上下滚动, 选择 Fdisk 条目。 <application>fdisk</application> 分区编辑器 进入 fdisk 分区编辑器后,选择 A ,FreeBSD 将使用全部的磁盘。当被告知 remain cooperative with any future possible operating systems时,回答 YES。使用 W 保存刚才的修改。现在使用 Q 退出 FDISK 编辑器。下面会看到有关 主引导区 的信息。 现在您已经在运行的系统上添加了一个磁盘, 因此应该选择 None Disk Label 编辑器 BSD partitions 接下来,您应该退出 sysinstall 并且再次启动它,并按照上面的步骤直接进入 Label 选项。进入 磁盘标签编辑器。 这就是您要创建的 BSD 分区。一个磁盘最多可以有 8 个分区,标记为 a-h。有几个分区标签有特殊的用途。 a 分区被用来作为根分区(/)。 系统磁盘(例如:从那儿启动的分区)必须有一个 a 分区。b 分区被用作交换分区,可以用很多磁盘用作交 换分区。 c 分区代表整个硬盘,或在 FreeBSD slice 模式下代表整个 slice。其它分区作为一般分区来使用。 sysinstall 的标签编辑器用 e 表示非 root 和非 swap 分区。在标签编辑器中,可以使用键入 C 创建一个文件系统。当提示这是否是一个 FS(文件系统)或 swap 时,选择 FS,然后给出一个加载点(如: /mnt)。 当在 post-install 模式时添加一个磁盘, sysinstall 不会在 /etc/fstab 中创建记录,所以是否指定加载点并不重要。 现在已经准备把新标签写到磁盘上,然后创建一个文件系统,可以按下 W。出现任何错误都会不能创建新的分区。可以退出标签编辑 器然后重新执行 sysinstall 完成 下面一步就是编辑 /etc/fstab,为您的磁盘添加一个新 记录。 使用命令行工具 使用 Slices 这步安装将允许磁盘与可能安装在您计算机上的其它操作系统一起 正确工作,而不会搞乱其它操作系统的分区。推荐使用这种方法来安装 新磁盘,除非您有更好的理由再使用 dedicated 模式! &prompt.root; dd if=/dev/zero of=/dev/da1 bs=1k count=1 &prompt.root; fdisk -BI da1 #初始化新磁盘 &prompt.root; bsdlabel -B -w da1s1 auto #加上标签 &prompt.root; bsdlabel -e da1s1 # 现在编辑您刚才创建的磁盘分区 &prompt.root; mkdir -p /1 &prompt.root; newfs /dev/da1s1e # 为您创建的每个分区重复这个操作 &prompt.root; mount /dev/da1s1e /1 # 挂上分区 &prompt.root; vi /etc/fstab # 完成之后,添加合适的记录到您的 /etc/fstab文件。 如果有一个 IDE 磁盘,记得要用 ad 替换前面的 da 专用模式 OS/2 如果您并没有安装其它的操作系统,可以使用 dedicated 模式。记住这种模式可能会弄乱 Microsoft 的操作系统,但不会对它进行破坏。 它不识别找到的 IBM &os2 的 appropriate 分区。 &prompt.root; dd if=/dev/zero of=/dev/da1 bs=1k count=1 &prompt.root; bsdlabel -Bw da1 auto &prompt.root; bsdlabel -e da1 # 创建 `e' 分区 &prompt.root; newfs /dev/da1e &prompt.root; mkdir -p /1 &prompt.root; vi /etc/fstab # 为 /dev/da1e添加一个记录 &prompt.root; mount /1 另一种方法: &prompt.root; dd if=/dev/zero of=/dev/da1 count=2 &prompt.root; bsdlabel /dev/da1 | bsdlabel -BR da1 /dev/stdin &prompt.root; newfs /dev/da1e &prompt.root; mkdir -p /1 &prompt.root; vi /etc/fstab # 为 /dev/da1e添加一个记录 &prompt.root; mount /1 RAID 软件 RAID Christopher Shumway Original work by Jim Brown Revised by RAIDsoftware RAIDCCD 连接磁盘驱动器配置 (CCD) 选择一个大容量存储比较好的解决方案,最重要的因素是产品的速度、 性能和成本。 通常这三者不可能都满足;要获得比较快和可靠的大容量存储设备, 就比较昂贵。但如果将成本降下来,那它的速度或可靠性就会打折扣。 在设计下面描述的系统时, 价格被选为最重要的因素, 接下来是速度和性能。 这个系统的数据传输速度基本上受限于网络。 性能也非常重要, CCD 驱动器上的所有数据都被备份到了 CD-R 盘, 可以很容易地对数据进行恢复。 在选择一个大容量的存储解决方案时,第一步是要设计您自己的需求。 如果您的需求更偏重于速度和性能,那么您的解决方案将就不同于上面的设计。 安装硬件 除了 IDE 系统磁盘外,还有三个 Western Digital 30GB、5400 RPM 的 IDE 磁盘构成了大约 90G 的连接磁盘驱动存储空间。 理想情况是每个 IDE 硬盘都独占 IDE 控制器和数据线, 但为了尽可能降低成本, 通常并不会安装更多的控制器, 而是通过配置跳线,使每个 IDE 控制器都管理一个主盘和一个从盘。 重启动后,系统 BIOS 被配置成自动检测硬盘。FreeBSD 检测到它们: ad0: 19574MB <WDC WD205BA> [39770/16/63] at ata0-master UDMA33 ad1: 29333MB <WDC WD307AA> [59598/16/63] at ata0-slave UDMA33 ad2: 29333MB <WDC WD307AA> [59598/16/63] at ata1-master UDMA33 ad3: 29333MB <WDC WD307AA> [59598/16/63] at ata1-slave UDMA33 如果 FreeBSD 没有检测到它们,请确定它们的跳线是否设置 正确。大多数 IDE 磁盘有一个 Cable Select 跳线。这个 不是 设置 master/slave 硬盘的跳线。查阅文档 信息来确定正确的跳线设置。 接下来考虑的是,如何创建文件系统。应该好好研究一下 &man.vinum.8; ()和 &man.ccd.4; 两种方式,在这里我们选择 &man.ccd.4; 安装 CCD &man.ccd.4; 允许用户将几个相同的的磁盘通过一个逻辑文件系统 连接起来。要使用 &man.ccd.4;,您需要在内核中配置 &man.ccd.4; 支持选项。把这行加入到内核配置文件中,然后重建内核: device ccd 对 &man.ccd.4; 的支持也可以内核模块的形式载入。 要安装 &man.ccd.4;, 首先需要使用 &man.bsdlabel.8; 来编辑硬盘: bsdlabel -w ad1 auto bsdlabel -w ad2 auto bsdlabel -w ad3 auto 此处将整个硬盘创建为 ad1c, ad2cad3c 下一步是改变 disklable 的类型。也可以使用 &man.bsdlabel.8; 来编辑: bsdlabel -e ad1 bsdlabel -e ad2 bsdlabel -e ad3 这儿在每个已经设置了 EDITOR 环境变量的磁盘上打开了 disklable,在我我例子中使用的是 &man.vi.1;。 可以看到: 8 partitions: # size offset fstype [fsize bsize bps/cpg] c: 60074784 0 unused 0 0 0 # (Cyl. 0 - 59597) 添加一个新的 e 分区给 &man.ccd.4; 用。这可以是 c 分区的一个副本, 但 必须4.2BSD。做完之后,您会看到一面这些: 8 partitions: # size offset fstype [fsize bsize bps/cpg] c: 60074784 0 unused 0 0 0 # (Cyl. 0 - 59597) e: 60074784 0 4.2BSD 0 0 0 # (Cyl. 0 - 59597) 建立文件系统 现在已给每个磁盘都加上了标签,下面需要建立 &man.ccd.4;。要这样做, 需要使用 &man.ccdconfig.8; 工具,同时要提供类似下面的选项: ccdconfig ccd0 32 0 /dev/ad1e /dev/ad2e /dev/ad3e 每个选项的意义和用法如下所示: 配置设备的第一个参数,在这是 /dev/ccd0c/dev/ 部分是任选项。 下一个参数是文件系统的插入页(interleave)。插入页定义了一个 磁盘块中一个分段或条带(stripe)的大小,通常是 512 个字节。所以一个为 32 的插入页将是 16,384 字节。 插入页为 &man.ccdconfig.8; 附带了标记。如果您要启用驱动器镜像, 需要在这儿指定它。在这个配置中没有做 &man.ccd.4; 的镜像,所以把它 设为 0 (zero)。 &man.ccdconfig.8; 的最后配置是设备的排列问题。使用完整的设备 路径名。 运行 &man.ccdconfig.8; 后 &man.ccd.4; 就配置好了。现在要创建文件 系统了,参考 &man.newfs.8; 选项,执行下同的命令: newfs /dev/ccd0c 自动创建 最后,要挂上 &man.ccd.4; ,需要先配置它。把当前的配置文件写入 /etc/ccd.conf 中,使用下面的命令: ccdconfig -g > /etc/ccd.conf 当重新启动系统时,如果 /etc/ccd.conf 存在, 脚本 /etc/rc 就运行 ccdconfig -C。 这样就能自动配置 &man.ccd.4; 以到它能被挂上。 如果启动进入了单用户模式,在 &man.mount.8; 上 &man.ccd.4; 之前,需要执行下面的命令来配置队列: ccdconfig -C 要自动挂接 &man.ccd.4;,需要为 &man.ccd.4; 在 /etc/fstab 中配置一个记录,以便在启动时它能被挂上。 如下所示: /dev/ccd0c /media ufs rw 2 2 Vinum 卷管理 RAIDsoftware RAID Vinum Vinum 卷管理是一个实现虚拟磁盘的块驱动设备工具。它使磁盘从 块设备的接口和数据映射中独立出来。与传统的存储设备相比,增加了 灵活性、性能和可靠性。 &man.vinum.8; 实现了 RAID-0、RAID-1 和 RAID-5 三种模式,它们既可以独立使用,也可组合使用。 参考 得到更多 &man.vinum.8; 的信息。 硬件 RAID RAID hardware FreeBSD 支持很多硬件 RAID 控制器。 这些硬件不需要 FreeBSD 指定软件来管理 RAID 系统。 使用 BIOS 支持的硬件,一般情况下这些硬件可以自行操作。 下面是一个简明的描述设置一个 Promise IDE RAID 控制器。 当硬件设备装好且系统重启后,屏幕上显示一个询问信息。接着进入硬件设置屏幕。在这里, 您可以把所有的磁盘联合在一起使用。这样 FreeBSD 将磁盘看作一个驱动器。其它 级别的 RAID 也可以相应的进行设置。 重建 ATA RAID1 阵列 FreeBSD 允许您热插拔阵列中损坏的磁盘。 在您重新启动系统之前请注意这一点。 您可能会在 /var/log/messages 或者在 &man.dmesg.8; 的输出中看到类似下面这些的内容: ad6 on monster1 suffered a hard error. ad6: READ command timeout tag=0 serv=0 - resetting ad6: trying fallback to PIO mode ata3: resetting devices .. done ad6: hard error reading fsbn 1116119 of 0-7 (ad6 bn 1116119; cn 1107 tn 4 sn 11)\\ status=59 error=40 ar0: WARNING - mirror lost 使用 &man.atacontrol.8;,查看更多的信息: &prompt.root; atacontrol list ATA channel 0: Master: no device present Slave: acd0 <HL-DT-ST CD-ROM GCR-8520B/1.00> ATA/ATAPI rev 0 ATA channel 1: Master: no device present Slave: no device present ATA channel 2: Master: ad4 <MAXTOR 6L080J4/A93.0500> ATA/ATAPI rev 5 Slave: no device present ATA channel 3: Master: ad6 <MAXTOR 6L080J4/A93.0500> ATA/ATAPI rev 5 Slave: no device present &prompt.root; atacontrol status ar0 ar0: ATA RAID1 subdisks: ad4 ad6 status: DEGRADED 首先您应将包含故障盘的 ata 通道卸下, 以便安全地将其拆除: &prompt.root; atacontrol detach ata3 换上磁盘 重新挂接 ata 通道: &prompt.root; atacontrol attach ata3 Master: ad6 <MAXTOR 6L080J4/A93.0500> ATA/ATAPI rev 5 Slave: no device present 将新盘作为热备盘加入阵列: &prompt.root; atacontrol addspare ar0 ad6 重建阵列: &prompt.root; atacontrol rebuild ar0 可以通过下面的命令来查看进度: &prompt.root; dmesg | tail -10 [output removed] ad6: removed from configuration ad6: deleted from ar0 disk1 ad6: inserted into ar0 disk1 as spare &prompt.root; atacontrol status ar0 ar0: ATA RAID1 subdisks: ad4 ad6 status: REBUILDING 0% completed 等待操作完成。 Marc Fonvieille Contributed by USB 存储设备 USB disks 到目前为止,有许多外部外部存储解决方案, 例如:通用串行总线 (USB):硬盘、USB thumbdrives、CD-R burners 等等。 &os; 为这些设备提供了支持。 配置 USB 大容量存储设备驱动,在 &man.umass.4;, 中提供了对 USB 存储设备的支持。如果您使用 GENERIC 内核,您不必要改变配置文件里的任何内容。 如果您使用了定制的内核,就要确定下面的行出现在您的内核配置文件里: device scbus device da device pass device uhci device ohci device usb device umass &man.umass.4; 驱动程序使用 SCSI 子系统来访问 USB 存储设备, 您的 USB 设备将被系统看成为一个 SCSI 设备。依靠您主板上的 USB 芯片, 您只须选择 device uhcidevice ohci 二者之一即可, 但是两者都加入内核配置文件当中也没有坏外。 不要忘了如果您加入了上面的几行要重新编译和安装内核。 如果您的 USB 设备是一个 CD-R 或 DVD 刻录机, SCSI CD-ROM 驱动程序, &man.cd.4;, 就必须加入内核中通过下面这行: device cd 由于刻录机被视为 SCSI 设备, 因此, 不应该在内核配置文件中使用 &man.atapicam.4; 驱动程序。 在 &os; 中已经提供了对 USB 2.0 控制器的内建支持; 然而, 您必须在编译内核时在配置中加入: device ehci 注意, 如果需要 USB 1.X 的支持, 您仍需要使用 &man.uhci.4; 和 &man.ohci.4; 驱动程序。 测试配置 配置好后准备进行测试:插入您的 USB 设备, 在系统信息中 (&man.dmesg.8;), 应该会出现像下面的设备: umass0: USB Solid state disk, rev 1.10/1.00, addr 2 GEOM: create disk da0 dp=0xc2d74850 da0 at umass-sim0 bus 0 target 0 lun 0 da0: <Generic Traveling Disk 1.11> Removable Direct Access SCSI-2 device da0: 1.000MB/s transfers da0: 126MB (258048 512 byte sectors: 64H 32S/T 126C) 当然啦,商标,设备标识 (da0) 和其它的细节信息会根据您的配置不同 而有所不同。 因为 USB 设备被看作 SCSI 设备中的一个, camcontrol 命令也能够用来列出 USB 存储设备和系统的关联: &prompt.root; camcontrol devlist <Generic Traveling Disk 1.11> at scbus0 target 0 lun 0 (da0,pass0) 如果设备上已经包含了文件系统, 现在应该就可以挂接它了。 如果需要, 请参阅 来了解如何在 USB驱动器上格式化和创建分区。 如果希望设备能够被普通用户挂接, 还需要做一些其它操作。 首先, 在 USB 存储设备连接到计算机上时, 系统自动生成的设备文件, 必须是该用户能够读写的。 一种做法是让所有属于 operator 组的用户都可以访问该设备。 要完成这项工作, 首先需要用 &man.pw.8; 来给用户指定组。 其次, 在生成设备文件时, operator 组应能读写它们。 这可以通过在 /etc/devfs.rules 中增加一些相应的设置来实现: [localrules=5] add path 'da*' mode 0660 group operator 如果系统中已经有其它 SCSI 磁盘, 则上述操作必须做一些变化。 例如, 如果系统中已经存在了设备名为 da0da2 的磁盘, 则第二行应改为: add path 'da[3-9]*' mode 0660 group operator 这会将系统中已经存在的磁盘, 排除在属于 operator 组的设备之外。 另外, 您还需要在 /etc/rc.conf 文件中, 启用 &man.devfs.rules.5; 规则集: devfs_system_ruleset="localrules" 接下来, 需要配置内核, 令普通用户能够挂接文件系统。 最简单的方法是将下面的配置加入到 /etc/sysctl.conf vfs.usermount=1 注意, 这个设置只有在下次重启系统时才会生效。 另外, 您也可以使用 &man.sysctl.8; 来设置这个变量。 最后一步是创建将要挂接文件系统的目录。 这个目录必须是属于将要挂接文件系统的用户的。 以 root 身份为用户建立属于该用户的 /mnt/username (此处 username 应替换成用户的登录名, 并把 usergroup 替换成用户所属的组): &prompt.root; mkdir /mnt/username &prompt.root; chown username:usergroup /mnt/username 假设已经插入了一个 USB 读卡设备, 并且系统将其识别为 /dev/da0s1, 由于这些设备通常是 FAT 文件系统, 用户可以这样挂接它们: &prompt.user; mount -t msdosfs -o -m=644,-M=755 /dev/da0s1 /mnt/username 如果拔出设备 (必须首先将其对应的磁盘卷卸下), 则您会在系统消息缓冲区中看到类似下面的信息: umass0: at uhub0 port 1 (addr 2) disconnected (da0:umass-sim0:0:0:0): lost device (da0:umass-sim0:0:0:0): removing device entry GEOM: destroy disk da0 dp=0xc2d74850 umass0: detached 深入阅读 除了 Adding Disks 和 Mounting and Unmounting File Systems 章之外,阅读 &man.umass.4;, &man.camcontrol.8;, 和 &man.usbdevs.8; 也是很有益的。 Mike Meyer Contributed by 创建和使用光学介质(CD) CDROMs creating 介绍 CD 与普通的磁盘相比有很多不同的特性。最初它们是不能被用户写入的。 由于没有磁头和磁道移动时的延迟,所以它们可以连续的进行读取。 方便的在两个系统之间进行数据的传输,比起相同大小的存储介质来说。 CD 有磁道,这关系到数据读取时的连续性而不是物理磁盘的性能。 要在 FreeBSD 中制作一个 CD,您要准备好要写到 CD 上的数据文件, 然后根据每个 tracks 写入到 CD。 ISO 9660 文件系统 ISO 9660 ISO 9660 文件系统被设计用来处理这些差异。 但令人遗憾的是, 它也有一些其他文件系统所没有的限制, 不过幸运的是, 它提供了一项扩展机制, 使得正确写入的 CD 能够超越这些限制, 而又能在不支持这些扩展的系统上正常使用。 sysutils/cdrtools sysutils/ port 包括了 &man.mkisofs.8;, 这是一个可以用来生成包含 ISO 9660 文件系统的数据文件的程序。 他也提供了对于一些扩展的支持选项,下面将详细介绍。 CD burner (刻录机) ATAPI 使用哪个工具来刻录 CD 取决于您的 CD 刻录机是 ATAPI 的, 还是其他类型的。 对于 ATAPI CD 刻录机, 可以使用基本系统附带的 burncd 程序。 SCSI 和 USB CD 刻录机, 则需要配合 cdrecord 程序使用, 它可以通过 sysutils/cdrtools port 安装。 除此之外, 在 ATAPI 接口的刻录机上, 也可以配合 ATAPI/CAM 模块 来使用 cdrecord 以及其它为 SCSI 刻录机撰写的工具。 如果您想使用带图形界面的 CD 刻录软件, 可以考虑一下 X-CD-RoastK3b。 这些工具可以通过使用预编译安装包, 或通过 sysutils/xcdroastsysutils/k3b ports 来安装。 X-CD-RoastK3b 需要 ATAPI/CAM 模块 配合 ATAPI 硬件。 mkisofs &man.mkisofs.8; 程序作为 sysutils/cdrtools port 的一部分, 将生成 ISO 9660 文件系统,其中包含 &unix; 命名空间中的文件名。 最简单的用法是: &prompt.root; mkisofs -o imagefile.iso /path/to/tree 文件系统 ISO 9660 这个命令将创建一个包含 ISO9660 文件系统的 imagefile.iso 文件,它是目录树 /path/to/tree 的一个副本。 在处理过程中, 它将文件名称映射为标准的 ISO9660 文件系统的文件名,将排除那些不典型的 ISO 文件系统的文件。 文件系统 HFS 文件系统 Joliet 有很多选项能够用来克服那些限制。特别的, 选项能够启用 Rock Ridge 扩展一般的 &unix; 系统, 选项能启用用于 Microsoft 系统的 Joliet 扩展, 选项能用来创建用于 &macos; 系统的 HFS 文件系统。 对于那些即将要在 FreeBSD 系统中使用 CD 的人来说, 选项能用来消除所有文件名的限制。当使用 选项时,它会产生一个 文件系统映像,它与您从那儿启动 FreeBSD 树是一样的,虽然它在许多方面也违反了 ISO 9660 的标准。 CDROMs 创建启动光盘 最后一个常用的选项是 。 它用来指定启动映像的位置, 用以生成 El Torito 启动 CD。 这个选项使用一个参数, 用以指定将写入 CD 的目录的根。 默认情况下, &man.mkisofs.8; 会以常说的 软盘模拟 方式来创建 ISO, 因此它希望引导映像文件的尺寸恰好是 1200, 1440 或 2880 KB。 某些引导加载器, 例如 FreeBSD 发行版磁盘, 并不使用模拟模式; 这种情况下, 需要使用 选项。 因此, 如果 /tmp/myboot 是一个包含了启动映像文件 /tmp/myboot/boot/cdboot 的可引导的 FreeBSD 系统, 您就可以使用下面的命令生成 ISO 9660 文件系统映像 /tmp/bootable.iso &prompt.root; mkisofs -R -no-emul-boot -b boot/cdboot -o /tmp/bootable.iso /tmp/myboot 完成这些工作之后, 如果您的内核中配置了 md, 就可以用下列命令来挂接文件系统了: &prompt.root; mdconfig -a -t vnode -f /tmp/bootable.iso -u 0 &prompt.root; mount -t cd9660 /dev/md0 /mnt 可以发现 /mnt/tmp/myboot 是一样的。 还可以使用 &man.mkisofs.8; 的其它选项来调整它的行为。特别是修改 ISO 9660 的划分格式,创建 Joliet 和 HFS 格式的磁盘。查看 &man.mkisofs.8; 联机手册得到更多的帮助。 burncd CDROMs burning 如果用的是 ATAPI 的 CD 刻录机,可以使用 burncd  命令来刻录您的 CD ISO 映像文件。 burncd 命令是基本  系统的一部分,中以使用 /usr/sbin/burncd 来安装。  用法如下: &prompt.root; burncd -f cddevice data imagefile.iso fixate cddevice 上刻录一份 imagefile.iso 的副本。 默认的设备是 /dev/acd0。 请参考 &man.burncd.8; 以了解设置写入速度的参数,如何在刻录完成之后自动弹出CD,以及刻录音频数据。 cdrecord 如果没有一个 ATAPI CD 刻录机,必须使用 cdrecord 来刻录您的 CD 。 cdrecord 不是基本系统的一部分;必须 从 sysutils/cdrtools 或适当的 package 安装它。基本系统的变化可能会引起这个程序的错误。可能是由 coaster 引起的。当升级系统时,同时需要升级 port, 或者如果您 使用 -STABLE, 那么在升级到新版本时也要升级 port。 cdrecord 有许多选项,基本用法与 burncd 相似。刻录一个 ISO 9660 映像文件只需这样做: &prompt.root; cdrecord dev=device imagefile.iso 使用 cdrecord 的比较巧妙的方法是找到使用的 。要找到正确的设置,可以使用 cdrecord 标记,这会产生这样的结果: CDROMs burning &prompt.root; cdrecord -scanbus Cdrecord-Clone 2.01 (i386-unknown-freebsd7.0) Copyright (C) 1995-2004 Jörg Schilling Using libscg version 'schily-0.1' scsibus0: 0,0,0 0) 'SEAGATE ' 'ST39236LW ' '0004' Disk 0,1,0 1) 'SEAGATE ' 'ST39173W ' '5958' Disk 0,2,0 2) * 0,3,0 3) 'iomega ' 'jaz 1GB ' 'J.86' Removable Disk 0,4,0 4) 'NEC ' 'CD-ROM DRIVE:466' '1.26' Removable CD-ROM 0,5,0 5) * 0,6,0 6) * 0,7,0 7) * scsibus1: 1,0,0 100) * 1,1,0 101) * 1,2,0 102) * 1,3,0 103) * 1,4,0 104) * 1,5,0 105) 'YAMAHA ' 'CRW4260 ' '1.0q' Removable CD-ROM 1,6,0 106) 'ARTEC ' 'AM12S ' '1.06' Scanner 1,7,0 107) * 这个列表列出了设备的的适当的 值。找到您的 CD burner ,使用三个用逗号分隔的数值来表示 .在 这个例子中,CRW 是 ,所以正确的输入应是 dev=1,5,0 。有一个很容易的方法可以指定这个值;看看 &man.cdrecord.1; 的介绍了解有关音轨,控制速度和其他的东西。 复制音频 CD 您可以这样复制 CD,把 CD 上面的音频数据解压缩出一系列的文件, 再把这些文件写到一张空白 CD 上。 这个过程对于 ATAPI 和 SCSI 驱动器来说有些微的不同。 SCSI 驱动器 使用 cdda2wav 来解压缩音频。 &prompt.user; cdda2wav -v255 -D2,0 -B -Owav 使用 cdrecord 来写 .wav 文件。 &prompt.user; cdrecord -v dev=2,0 -dao -useinfo *.wav 确保 2,0 被适当地设置了, 具体方法在 中有所描述。 ATAPI 驱动器 ATAPI CD 驱动用 /dev/acddtnn表示每个轨道, 这里 d 是驱动器号, nn 是轨道号,由两位小数位组成,省略前缀零。 所以第一个盘片上的第一个轨道就是 /dev/acd0t01,第二个就是 /dev/acd0t02,第三个就是 /dev/acd0t03,等等。 请务必确认在 /dev 中出现了对应的文件。 如果您发现有某些项目缺失, 则应强制系统重新识别介质: &prompt.root; dd if=/dev/acd0 of=/dev/null count=1 使用 &man.dd.1; 解压缩每个轨道。当解压缩文件的时候您也必须使用 一个特殊的块大小。 &prompt.root; dd if=/dev/acd0t01 of=track1.cdr bs=2352 &prompt.root; dd if=/dev/acd0t02 of=track2.cdr bs=2352 ... 使用 burncd 把解压缩的文件刻录到光盘上。您必须指定 这些文件是音频文件,这样 burncd 会在刻录完成时 结束光盘。 &prompt.root; burncd -f /dev/acd0 audio track1.cdr track2.cdr ... fixate 复制数据 CD 您可以把数据 CD 复制成一个与之等价的映像文件, 可以使用 &man.mkisofs.8; 创建这种文件, 或使用它来复制任何数据 CD。 这里给出的例子假定您的 CDROM 设备是 acd0, 您应将其替换为您实际使用的 CDROM 设备。 &prompt.root; dd if=/dev/acd0 of=file.iso bs=2048 现在您有一个映像文件了,您可以像上面描述的那样把它刻录成 CD。 使用数据 CD 现在您已经创建了一张标准的数据 CDROM,您或许想要 挂载来读取上面的设备。 默认情况下,&man.mount.8; 假定文件系统是 ufs 类型的。如果您尝试下面的命令: &prompt.root; mount /dev/cd0 /mnt 您会得到一条 Incorrect super block 的错误信息,没有挂载成功。CDROM 不是 UFS 文件系统,所以试图这样挂载它是 是不行的。您需要告诉 &man.mount.8; 文件系统是 ISO9660 类型的,这样 就可以了。只需要指定 &man.mount.8; 的 选项。例如, 如果您想要挂载 CDROM 设备, /dev/cd0/mnt 目录,您需要执行: &prompt.root; mount -t cd9660 /dev/cd0 /mnt 注意您的设备名 (在这个例子中是 /dev/cd0)可能 有所不同,取决于您的 CDROM 使用的接口。另外, 选项等同于执行 &man.mount.cd9660.8;。上面的例子可以缩短 为: &prompt.root; mount_cd9660 /dev/cd0 /mnt 用这种方法您基本可以使用任何买到的数据 CDROM。 然而某些有 ISO 9660 扩展的光盘可能会行为古怪。 例如,joliet 光盘用两个字节的 unicode 字符存储所有的文件名。 FreeBSD 内核并不使用 Unicode, 但 &os; CD9660 驱动可以将 Unicode 字符自动转换为内核可以识别的形式。 如果您发现有些非英文字符显示为问号, 就绪要使用 选项来指定字符集了。 欲了解进一步的详情, 请参见联机手册 &man.mount.cd9660.8;。 如果希望通过 选项来进行字符集转换, 则内核会需要加载 cd9660_iconv.ko 模块。 这项工作可以通过在 loader.conf 中加入下列配置: cd9660_iconv_load="YES" 并重新启动计算机来完成, 除此之外, 也可以通过 &man.kldload.8; 来手动加载。 有时候,当您试图挂载 CDROM 的时候,会得到一条 Device not configured 的错误信息。这通常 表明 CDROM 驱动认为托盘里没有光盘, 或者驱动器在总线上不可见。 需要几秒钟时间等待 CDROM 驱动器辨别已经接到反馈的信息, 请耐心等待。 有时候,SCSI CDROM 可能会找不到,因为没有足够的 时间来应答总线的 reset 信号。如果您有一个 SCSI CDROM 请将下面的选项添加到您的内核 配置文件并重建您的内核。 options SCSI_DELAY=15000 这个告诉您的 SCSI 总线启动时暂停 15 秒钟, 给您的 CDROM 驱动器足够的机会来应答 总线 reset 信号。 刻录原始数据 CD 您可以选择把一个文件目录刻录到 CD 上而不用 创建 ISO 9660 文件系统。有些人这么做是为了备份的 目的。这个运行的比刻录一个标准 CD 速度要快得多: &prompt.root; burncd -f /dev/acd1 -s 12 data archive.tar.gz fixate 要重新找回这样刻录到 CD 上的数据, 您必须从原始设备节点读取数据: &prompt.root; tar xzvf /dev/acd1 您不能像挂载一个通常的 CDROM 一样挂载这张光盘。 这样的 CDROM 也不能在除了 FreeBSD 之外的任何操作系统上读出。 如果您想要可以挂载 CD,或者 和另一种操作系统共享数据,您必须像上面描述的那样使用 &man.mkisofs.8;。 Marc Fonvieille Contributed by CD burner ATAPI/CAM driver 使用 ATAPI/CAM 驱动 这个驱动允许 ATAPI 设备(CD-ROM, CD-RW, DVD 驱动器等...)通过 SCSI 子系统访问, 这样允许使用像 sysutils/cdrdao 或者 &man.cdrecord.1; 这样的程序。 要使用这个驱动, 您需要把下面这行添加到 /boot/loader.conf 文件中: atapicam_load="YES" 接下来, 重新启动计算机。 如果您希望将 &man.atapicam.4; 以静态联编的形式加入内核, 则需要在内核配置文件中加入这行: device atapicam 此外还需要在内核配置文件中加入: device ata device scbus device cd device pass 这些应该已经有了。 然后, 重新联编并安装新内核, 并重新启动计算机。 在引导过程中, 您的刻录机将会出现在内核的提示信息中, 就像这样: acd0: CD-RW <MATSHITA CD-RW/DVD-ROM UJDA740> at ata1-master PIO4 cd0 at ata1 bus 0 target 0 lun 0 cd0: <MATSHITA CDRW/DVD UJDA740 1.00> Removable CD-ROM SCSI-0 device cd0: 16.000MB/s transfers cd0: Attempt to query device size failed: NOT READY, Medium not present - tray closed 驱动器现在可以通过 /dev/cd0 设备名访问了,例如要 挂载 CD-ROM 到 /mnt,只需要键入下面的 命令: &prompt.root; mount -t cd9660 /dev/cd0 /mnt 作为 root,您可以运行下面的 命令来得到刻录机的 SCSI 地址: &prompt.root; camcontrol devlist <MATSHITA CDRW/DVD UJDA740 1.00> at scbus1 target 0 lun 0 (pass0,cd0) 这样 1,0,0 就是 SCSI 地址了,可以被 &man.cdrecord.1; 和其他的 SCSI 程序使用。 有关 ATAPI/CAM 和 SCSI 系统的更多信息, 可以参阅 &man.atapicam.4; 和 &man.cam.4; 手册 页。 Marc Fonvieille Contributed by Andy Polyakov With inputs from 创建和使用光学介质(DVD) DVD burning 介绍 和 CD 相比,DVD 是下一代光学存储介质技术。 DVD 可以容纳比任何 CD 更多的数据,已经成为现今视频出版业的标准。 我们称作可记录 DVD 的有五种物理记录格式: DVD-R:这是第一种可用的 DVD 可记录格式。 DVD-R 标准由 DVD Forum 定义。 这种格式是一次可写的。 DVD-RW:这是 DVD-R 标准的可覆写版本。 一张 DVD-RW 可以被覆写大约 1000 次。 DVD-RAM:这也是一种被 DVD Forum 所支持的可覆写格式。 DVD-RAM 可以被看作一种可移动硬盘。 然而,这种介质和大部分 DVD-ROM 驱动器以及 DVD-Video 播放器不兼容; 只有少数 DVD 刻录机支持 DVD-RAM。 请参阅 以了解关于如何使用 DVD-RAM 的进一步详情。 DVD+RW:这是一种由 DVD+RW Alliance 定义的可覆写格式。一张 DVD+RW 可以被覆写大约 1000 次。 DVD+R:这种格式是 DVD+RW 格式的一次可写变种。 一张单层的可记录 DVD 可以存储 4,700,000,000  字节,相当于 4.38 GB 或者说 4485 MB (1 千字节等于 1024 字节)。 必须说明一下物理介质与应用程序的分歧。 例如 DVD-Video 是一种特殊的文件系统, 可以被覆写到任何可记录的 DVD 物理介质上: DVD-R、DVD+R、DVD-RW 等等。在选择介质类型之前, 您一定要确认刻录机和 DVD-Video 播放器 (一种单独的播放器或者计算机上的 DVD-ROM 驱动器) 是和这种介质兼容的。 配置 &man.growisofs.1; 将被用来实施 DVD 刻录。 这个命令是 dvd+rw-tools 工具集 (sysutils/dvd+rw-tools) 的一部分。 dvd+rw-tools 支持所有的 DVD 介质类型。 这些工具将使用 SCSI 子系统来访问设备,因此 ATAPI/CAM 支持 必须加入内核。 如果您的刻录机采用 USB 接口则不需要这么做,请参考 来了解 USB 设备配置的进一步详情。 此外,还需要启用 ATAPI 设备的 DMA 支持。 这一工作可以通过在 /boot/loader.conf 文件中加入下面的行来完成: hw.ata.atapi_dma="1" 试图使用 dvd+rw-tools 之前您应该参考 dvd+rw-tools 硬件兼容性列表 是否有与您的 DVD 刻录机有关的信息。 如果您想要一个图形化的用户界面,您应该看一看 K3b (sysutils/k3b),它提供了 &man.growisofs.1; 的一个友好界面和许多其他刻录工具。 刻录数据 DVD &man.growisofs.1; 命令是 mkisofs 的前端,它会调用 &man.mkisofs.8; 来创建文件系统布局,完成到 DVD 上的刻录。 这意味着您不需要在刻录之前创建数据映像。 要把 /path/to/data 目录的数据刻录到 DVD+R 或者 DVD-R 上面,使用下面的命令: &prompt.root; growisofs -dvd-compat -Z /dev/cd0 -J -R /path/to/data 选项传递给 &man.mkisofs.8; 用于文件系统创建 (这表示创建带有带有 joliet 和 Rock Ridge 扩展的 ISO 9660 文件系统), 参考 &man.mkisofs.8; 联机手册了解更多细节。 选项 用来在任何情况下初始刻录会话: 不管多会话与否。 DVD 设备,/dev/cd0, 必须依照您的配置做出改变。 参数会结束光盘, 光盘成为不可附加的。这会提供更多的和 DVD-ROM 驱动器的介质兼容性。 也可以刻录成一个 pre-mastered 映像, 例如记录一个映像文件 imagefile.iso, 我们可以运行: &prompt.root; growisofs -dvd-compat -Z /dev/cd0=imagefile.iso 刻录的速度可以被检测到并自动进行调整, 根据介质和驱动器的使用情况。如果您想强制改变速度, 可以使用 参数。更多的信息,请看 &man.growisofs.1; 联机手册。 DVD DVD-Video 刻录 DVD-Video DVD-Video 是一种特殊的基于 ISO 9660 和 micro-UDF (M-UDF) 规范的文件系统。 DVD-Video 也呈现了一个特殊的数据格式, 这就是为什么您需要一个特殊的程序像 multimedia/dvdauthor 来制作 DVD 的原因。 如果您已经有了 DVD-Video 文件系统的映像, 就可以以同样的方式制作另一个映像,可以参看前面章节的例子。 如果您想制作 DVD 并想放在特定的目录中,如在目录 /path/to/video 中, 可以使用下面的命令来刻录 DVD-Video: &prompt.root; growisofs -Z /dev/cd0 -dvd-video /path/to/video 选项将传递给 &man.mkisofs.8; 并指示它创建一个 DVD-Video 文件系统布局。 除此之外。 选项也包含了 &man.growisofs.1; 选项。 DVD DVD+RW 使用 DVD+RW 不像 CD-RW, 一个空白的 DVD+RW 在每一次使用前必须先格式化。 &man.growisofs.1; 程序将会适时的自动对其进行适当的处理, 这是 recommended 的方式。您也可以使用 dvd+rw-format 来对 DVD+RW 进行格式化: &prompt.root; dvd+rw-format /dev/cd0 您只需要执行这样的操作一次,牢记只有空白的 DVD+RW 介质才需要格式化。您可以以前面章节同样的方式来刻录 DVD+RW。 如果您想刻录新的数据 (刻录一个新的完整的文件系统 而不仅仅是追加一些数据) 到 DVD+RW,您不必再将其格式化成空白盘, 您只须要直接覆盖掉以前的记录即可。 (执行一个新的初始化对话), 像这样: &prompt.root; growisofs -Z /dev/cd0 -J -R /path/to/newdata DVD+RW 格式化程序为简单的向以前的记录追加数据提供了可能性。 这个操作有一个新的会话和一个已经存在的会话合并而成。 它不需要多个写会话过程, &man.growisofs.1; 将在介质上 增加 ISO 9660 文件系统。 例如,我们想追加一些数据到到我们以前的 DVD+RW 上,我们可以使用下面的命令: &prompt.root; growisofs -M /dev/cd0 -J -R /path/to/nextdata 在以后的写操作时, 应使用与最初的刻录会话时相同的 &man.mkisofs.8; 选项。 如果您想获得与 DVD-ROM 驱动更好的兼容性,可以使用 选项。 在 DVD+RW 这种情况下, 这样做并不妨碍您添加数据。 如果出于某种原因您真的想要空白介质盘, 可以执行下面的命令: &prompt.root; growisofs -Z /dev/cd0=/dev/zero DVD DVD-RW 使用 DVD-RW DVD-RW 接受两种光盘格式:增补顺序写入和受限式覆写。默认的 DVD-RW 盘是顺序写入格式。 空白的 DVD-RW 能够直接进行刻录而不需要格式化操作, 然而非空的顺序写入格式的 DVD-RW 需要格式化才能写入新的初始区段。 要格式化一张 DVD-RW 为顺序写入模式,运行: &prompt.root; dvd+rw-format -blank=full /dev/cd0 一次完全的格式化 () 在 1x 倍速的介质上将会花费大约 1 个小时。快速格式化可以使用 选项来进行,如果 DVD-RW 要以 Disk-At-Once (DAO) 模式刻录的话。要以 DAO 模式刻录 DVD-RW,使用命令: &prompt.root; growisofs -use-the-force-luke=dao -Z /dev/cd0=imagefile.iso 选项不是必需的, 因为 &man.growisofs.1; 试图最低限度的检测 (快速格式化) 介质并进行 DAO 写入。 事实上对于任何 DVD-RW 都应该使用受限式覆写模式, 这种格式比默认的增补顺序写入更加灵活。 在一张顺序 DVD-RW 上写入数据,使用和其他 DVD 格式相同的指令: &prompt.root; growisofs -Z /dev/cd0 -J -R /path/to/data 如果您想在您以前的刻录上附加数据,您必须使用 &man.growisofs.1; 的 选项。然而, 如果您在一张增补顺序写入模式的 DVD-RW 上附加数据, 将会在盘上创建一个新的区段,结果就是一张多区段光盘。 受限式覆写格式的 DVD-RW 在新的初始化区段前不需要格式化, 您只是要用 选项覆写光盘,这和 DVD+RW 的情形是相似的。也可以用和 DVD+RW 同样方式的 选项把现存的 ISO 9660 文件系统写入光盘。 结果会是一张单区段 DVD。 要把 DVD-RW 置于受限式覆写格式, 必须使用下面的命令: &prompt.root; dvd+rw-format /dev/cd0 更改回顺序写入模式使用: &prompt.root; dvd+rw-format -blank=full /dev/cd0 多区段 几乎没有哪个 DVD-ROM 驱动器支持多区段 DVD,它们大多数时候都只读取第一个区段。 顺序写入格式的 DVD+R、DVD-R 和 DVD-RW 可以支持多区段, DVD+RW 和 DVD-RW 受限式覆写格式不存在多区段的概念。 在 DVD+R、DVD-R 或者 DVD-RW 的顺序写入格式下, 一次初始化 (未关闭) 区段之后使用下面的命令, 将会在光盘上添加一个新的区段: &prompt.root; growisofs -M /dev/cd0 -J -R /path/to/nextdata 对 DVD+RW 或者 DVD-RW 在受限式覆写模式下使用这条命令, 会合并新区段到存在的区段中来附加数据。 结果就是一张单区段光盘。 这是在这些介质上用于在最初的写操作之后添加数据的方式。 介质上的一些空间用于区段之间区段的开始与结束。 因此,应该用大量的数据添加区段来优化介质空间。 对于 DVD+R 来说区段的数量限制为 154, 对于 DVD-R 来说大约是 2000,对于双层 DVD+R 来说是 127。 更多的信息 要获得更多的关于 DVD 的信息 dvd+rw-mediainfo /dev/cd0 命令可以运行来获得 更多的信息。 更多的关于 dvd+rw-tools 的信息可以在 &man.growisofs.1; 联机手册找到,在 dvd+rw-tools web sitecdwrite mailing list 联接中也可找到。 dvd+rw-mediainfo 命令的输出结果记录, 以及介质的问题会被用来做问题报告。 如果没有这些输出, 就很难帮您解决问题。 使用 DVD-RAM DVD DVD-RAM 配置 DVD-RAM 刻录机通常使用 SCSI 或 ATAPI 两种接口之一。 对于 ATAPI 设备, DMA 传输模式必须手工启用。 这一工作可以通过在 /boot/loader.conf 文件中增加下述配置来完成: hw.ata.atapi_dma="1" 初始化介质 如本章前面的介绍所言, DVD-RAM 可以视为一移动硬盘。 与任何其它型号的移动硬盘类似, 首次使用它之前, 应首先 初始化 DVD-RAM。 在下面的例子中, 我们将在全部空间上使用标准的 UFS2 文件系统: &prompt.root; dd if=/dev/zero of=/dev/acd0 bs=2k count=1 &prompt.root; bsdlabel -Bw acd0 &prompt.root; newfs /dev/acd0 您应根据实际情况将 acd0 改为您所使用的设备名。 使用介质 一旦您在 DVD-RAM 上完成了前面的操作, 就可以像普通的硬盘一样挂接它了: &prompt.root; mount /dev/acd0 /mnt 然后就可以正常地对 DVD-RAM 进行读写了。 Julio Merino 原作 Martin Karlsson 重写 创建和使用软盘 把数据存储在软盘上有时也是十分有用的。 例如, 在没有其它可靠的存储介质, 或只需将少量数据传到其他计算机时。 这一章将介绍怎样在 FreeBSD 上使用软盘。 在使用 DOS 3.5 英寸软盘时首要要涉及的就是格式化, 但其概念与其它的软盘格式化极为类似。 格式化软盘 设备 软盘的访问像其它设备一样是通过在 /dev 中的条目来实现的。 直接访问软盘时, 只需简单地使用 /dev/fdN 来表示。 格式化 一张软盘在使用这前必须先被低级格式化。 通常卖主已经做过了,但格式化是检测介质完整性的一种好方法。 尽管这有可能会强取大量(或少量)的硬盘大小,但 大部分磁盘都能被格式化设计为 1440kB 。 低级格式化软盘你需要使用 &man.fdformat.1; 命令。这个程序需要设备名作为参数。 要留意一切错误信息,这些信息能够帮助你确定 磁盘的好与坏。 软盘的格式化 使用 /dev/fdN 设备来格式化软盘。插入一张新的 3.5 英寸的软盘在你的设备中: &prompt.root; /usr/sbin/fdformat -f 1440 /dev/fd0 磁盘标签 经过低级格式化后, 你需要给它分配一个标签。 这个磁盘标签以后会被删去, 但系统需要使用它来确定磁盘的尺寸。 新的磁盘标签将会接管整个磁盘,会包括所有合适的关于软盘的 geometry 信息。 磁盘标签的 geometry 值列在 /etc/disktab中。 现在可以用下面的方法来使用 &man.bsdlabel.8; 了: &prompt.root; /sbin/bsdlabel -B -w /dev/fd0 fd1440 文件系统 现在对软盘进行高级格式化。 这会在它上面安置一个新的文件系统,可使 FreeBSD 来对它进行读写。 在创建完新的文件系统后,磁盘标签将被消毁,所以如果你想重新格式化磁盘, 你必须重新创建磁盘标签。 软盘的文件系统可以选择 UFS 或 FAT 。 FAT 是通常情况下软盘比较好的选择。 要制作新的文件系统在软盘上,可以使用下面的命令: &prompt.root; /sbin/newfs_msdos /dev/fd0 现在磁盘已经可以进行读取和使用。 使用软盘 要使用软盘,需要先使用 &man.mount.msdosfs.8; 挂接它。 除此之外, 也可以使用在 ports 套件中的 emulators/mtools 程序。 用磁带机备份 tape media 主流的磁带机有 4mm, 8mm, QIC, mini-cartridge 和 DLT。 4mm (DDS: Digital Data Storage) tape media DDS (4mm) tapes tape media QIC tapes 4mm 磁带机正在逐步取代 QIC 成为工作站备份数据的首选设备。 在 Conner 收购了 QIC 磁带机领域领先的制造商 Archive 之后不久, 即不再生产这种磁带机, 这使得这一趋势变得愈加明显。 4mm 的驱动器更加小和安静,但对于数据保存的可靠性仍不及 8mm 驱动器。它要比 8mm 的便宜和小得多 (3 x 2 x 0.5 inches, 76 x 51 x 12 mm) 。和 8mm 的一样,读写关的寿命都不长,因为它们同样使用螺旋式 的方式来读写。 这些设备的数据传输的速度约在 ~150 kB/s 到 ~500 kB/s 之间, 存储空间从 1.3 GB 到 2.0 GB 之间,硬件压缩可使空间加倍。磁带库 单元可以有 6 台磁带机,120 个磁带匣,以自动切换的方式使用同一个磁带柜, 磁带库的容量可达 240 GB 。 DDS-3 标准现在支持的磁带机容量最高可达到 12 GB (或压缩的 24 GB )。 4mm 和 8mm 同样都使用螺旋式读写的方式,所有螺旋式读写的优点及缺点, 都可以在 4mm 和 8mm 磁带机上看到。 磁带在经过 2,000 次的使用或 100 次的全部备份后,就该退休了。 8mm (Exabyte) tape media Exabyte (8mm) tapes 8mm 磁带机是最常见的 SCSI 磁带机,也是磁带交换的最佳选择。几乎每个 工作站都有一台 2 GB 8mm 磁带机。8mm 磁带机可信度高、方便、安静。 卡匣小 (4.8 x 3.3 x 0.6 inches; 122 x 84 x 15 mm)而且不贵。8mm 磁带机 的下边是一个短短的读写头,而读写头的寿命取决于磁带经过读写头时,相对高 速运动情况。 数据传输速度约在 250 kB/s 到 500 kB/s 之间,可存储的空间从 300 MB 到 7 GB,硬件压缩可使空间加倍。磁带库单元可以有 6 台磁 带机,120 个磁带匣,以自动切换的方式使用同一个磁带柜,磁带库的容量可达 840+ GB。 Exabyte Mammoth 模型支持 12 GB 的容量在一个磁带 上(压缩后可达 24 GB )相当于普通磁带的二倍。 数据是使用螺旋式读写的方式记录在磁带上的,读写头和磁带约相差 6 度, 磁带以 270 度缠绕着轴,并抵住读写头,轴适时地旋转,使得磁带具有高密度, 从一端到另一端并可使磁道紧密地分布。 QIC tape media QIC-150 QIC-150 磁带和磁带机可能是最常见的磁带机和介质了。 QIC 磁带机是最便宜的 正规 备份设备。 它的缺点在于介质的价格较高。 QIC 磁带要比 8mm 或 4mm 磁带贵, 每 GB 的数据存储价格可能最高高出 5 倍。 但是, 如果您的需求能够为半打磁带所满足的话, 那么 QIC 可能是明智之选。 QIC 是 常见的磁带机。 每个站点都会有某种密度的 QIC。 这有时是一种麻烦, QIC 有很多在外观上相似(有时一样),但是密度不同的磁带。 QIC 磁带机噪音很大。 它们在寻址以及读写时都会发出声音。 QIC 磁带的规格是 6 x 4 x 0.7 英寸 (152 x 102 x 17 毫米)。 数据传输的速度介于 150 kB/s 到 500 kB/s 之间,可存储的空间 从 40 MB 到 15 GB。较新的 QIC 磁带机具有硬件压缩的功能。 QIC 的使用率愈来愈低,渐渐被 DAT 所取代。 数据以磁道的方式记录在磁带上,磁道数及磁道的宽度会根据容量而有所不同。 通常新的磁带机具有的向后兼容的读取功能(通常也具备写入的功能)。对于数据 的安全性,QIC 具有不错的评价。 磁带机在经过 5,000 次的使用后,就该退休了。 DLT tape media DLT 在这一章列出的磁带机中 DLT 具有最快的数据传输率。 1/2" (12.5mm) 的 磁带包含在单轴的磁带匣 (4 x 4 x 1 inches; 100 x 100 x 25 mm)中。磁带匣 的一边是一个旋转匣道,通过匣道的开合,可以让磁带卷动。磁带匣内只有一个 轴,而本章中所提到的其他磁带匣都是有两个轴的(9磁道磁带机例外)。 数据传输的速度约 1.5 MB/s,是 4mm, 8mm, 或 QIC 磁带机的三倍。 可存储的空间从 10 GB 到 20 GB,具有磁带机数据库。磁带机数据库 单元可以有 1 to 20 台磁带机,5 到 900 个磁带匣,磁带机数据库的容量可达 50 GB 到 9 TB 。 如果要压缩的话,DLT 型 IV 格式的磁带机最高可支持 70 GB 的存储 容量。 数据存储在平行于磁带运行方向的磁道上(就像 QIC 磁带),一次写入两个 磁道。读写头的寿命相当长,每当磁带停止前进,磁带与读写头之间没有相对运动。 AIT tape media AIT AIT 是 Sony 开发的一种新格式,每个磁带最高可以存储 50 GB。磁带 机使用内存芯片来保存磁带上的索引内容。这个索引能够被磁带机驱动器快速阅读 来搜索磁带机上文件所处的位置,而不像其他的磁带机需要花几分钟的时间才能找 到文件。像 SAMS:Alexandria 这样的软件:能够操 作四十或者更多的 AIT 磁带库,直接使用内存芯片来进行通信把内容显示在屏幕上, 以决定把什么文件备份到哪个磁带上,加载和恢复数据。 像这样的库成本大概在 $20,000 美元左右,零售市场可能还要贵一点。 第一次使用新的磁带机 当在一块完全空白的磁带上尝试定入数据时,会得到类似下面这样的错误信息: sa0(ncr1:4:0): NOT READY asc:4,1 sa0(ncr1:4:0): Logical unit is in process of becoming ready 信息指出这块磁带没有块编号 (block 编号为 0)。在 QIC-525 之后的所有 QIC 磁带,都采用 QIC-525 标准,必须写入一个 Identifier Block 。对于这种问题, 有以下两种解决的办法: mt fsf 1 可以让磁带机对磁带写入 Identifier Block 。 使用面板上的按钮磁带。 再插入一次,并存储 dump 数据到磁带上。 这时dump 将传回 DUMP: End of tape detected ,然后您会得到这样的错误信息: HARDWARE FAILURE info:280 asc:80,96 这时用 mt rewind 来倒转磁带。 磁带操作的后续操作就完成了。 用软盘备份 能够使用软盘来备份数据吗 backup floppies floppy disks 软磁盘通常是用来备份的设备中不太合适的设备: 这种设备不太可靠,特别是长期使用。 备份和恢复都很慢 它们只有非常有限的存储容量。 然而,如果没有其它的备份数据的方法,那软盘备份总比没有备份要好。 如果必须使用软盘的话,必须确保盘片的质量。软盘在办公室中使用已经有许多 年了。最好使用一些名牌厂商的产品以确保质量。 如何备份数据到软盘 最好的备份数据到软盘的方法是使用 &man.tar.1; 程序加上 选项, 它可以允许数据备份到多张软盘上。 要备份当前目录中所有的文件可以使用这个命令 (需要有 root权限): &prompt.root; tar Mcvf /dev/fd0 * 当第一张盘满的时候, &man.tar.1; 会指示您插入下一张盘,插入第二张盘之后就按回车。 Prepare volume #2 for /dev/fd0 and hit return: 这个步骤可能需要重复很多次,直到这些文件备份完成为止。 可以压缩备份吗 tar gzip compression 不幸的是,&man.tar.1; 在为多卷文件作备份时是不允许使用 选项的。当然,可以用 &man.gzip.1; 压缩所有的文件,把它们打包到磁盘,以后在用 &man.gunzip.1; 解开。 如何恢复备份 要恢复所有文件: &prompt.root; tar Mxvf /dev/fd0 有两种方法来恢复软盘中的个别文件。首先,就要用第一张软盘启动: &prompt.root; tar Mxvf /dev/fd0 filename &man.tar.1; 程序会提示您插入后面的软盘,直到它找到所需要的文件。 如果您知道哪个文件在哪个盘上,您就可以插入那张盘,然后使用上同同样的命令。 如果软盘上的第一个文件与前面的文件是连续的,那 &man.tar.1; 命令会警告您它无法 恢复,即使您不要求它这样做。 Lowell Gilbert 原作 备份策略 设计备份计划的第一要务是确认以下问题皆已考虑到: 磁盘故障 文件的意外删除 随机的文件损毁 机器完全损毁 (例如火灾), 包括破坏全部在线备份。 针对上述的每个问题采用完全不同的技术来解决是完全可行的。 除了只包含少量几乎没有价值数据的个人系统之外, 一般来说很少有一种技术能够同时兼顾前面所有的需要。 可以采用的技术包括: 对整个系统的数据进行存档, 备份到永久性的离线介质上。 这种方法实际上能够提供针对前面所有问题的保护, 但这样做通常很慢, 而且恢复时会比较麻烦。 您可以将备份置于近线或在线的状态, 然而恢复文件仍然是一个难题, 特别是对没有特权的那些用户而言。 文件系统快照。 这种技术实际上只对无意中删除文件这一种情况有用, 但在这种情况下它会提供 非常大 的帮助, 而且访问迅速, 操作容易。 直接复制整个文件系统和/或磁盘 (例如周期性地对整个机器做 &man.rsync.1;)。 通常这对于在网络上的单一需求最为适用。 要为磁盘故障提供更为通用的保护, 通常这种方法要逊于 RAID。 对于恢复无意中删除的文件来说, 这种方法基本上与 UFS 快照属于同一层次, 使用哪一个取决于您的喜好。 RAID。 它能够最大限度地减少磁盘故障导致的停机时间。 其代价是需要处理更为频繁的磁盘故障 (因为磁盘的数量增加了), 尽管这类故障不再需要作为非常紧急的事项来处理。 检查文件的指纹。 &man.mtree.8; 工具对于这种操作非常有用。 尽管这并不是一种备份的技术, 但它能够确保您有机会注意到那些您需要求助于离线备份的事情。 这对于离线备份非常重要, 而且应有计划地加以检查。 很容易列举更多的技术, 它们中有许多实际上是前面所列出的方法的变种。 特别的需求通常会需要采用特别的技术 (例如, 备份在线运行的数据库, 往往需要数据库软件提供某种方法来完成中间步骤) 来满足。 最重要的事情是, 一定要了解需要将数据保护起来免受何种风险, 以及发生问题时应该如何处理。 备份程序 有三个主要的备份程序 &man.dump.8;、&man.tar.1; 和 &man.cpio.1;。 Dump 和 Restore 备份软件 dump / restore dump restore dumprestore 是 &unix; - 传统的备份程序。它以 block 而不是以文件为单位来备份数据、链接或目录。 - dump 备份的是设备上的整个文件系统,不能只备份一 - 一个文件系统的部分或是用到两个以上文件系统的目录树。 - dump 不会写文件和目录到磁带机,而是写入包含文件 - 和目录的原始数据块。 - - 如果在您的 root 目录使用 dump ,将不需要 - 备份 /home/usr 或其他目录, + 传统的备份程序。 它以 block 而不是以文件为单位来备份数据、链接或目录。 + dump 备份的是设备上的整个文件系统, + 不能只备份一个文件系统的部分或是用到两个以上文件系统的目录树。 + 与其他备份软件不同的是, + dump 不会写文件和目录到磁带机, 而是写入包含文件 + 和目录的原始数据块。 当需要恢复数据的时候,restore + 默认在 /tmp/ 下保存临时数据 — + 如果你正在操作的恢复盘只有比较小的 /tmp + 的话, 你可能需要把环境变量 TMPDIR + 设置到一个有更多空间的目录, 使得此过程更容易成功。 + + 如果在您的 root 目录使用 dump, + 将不需要备份 /home/usr 或其他目录, 因为这些是典型的其他文件系统或符号连接到那些文件系统的加载点。 dump 是最早出现于 AT&T UNIX 的 Version 6 (约 1975)。 - 默认的参数适用于 9-track 磁带(6250 bpi),所以如果要用高密度的磁带(最高可达 - 62,182 ftpi),就不能用默认的参数,而要另外指定参数。这些默认值必须在命令行被 - 修改以更好地利用当前磁带机的功能。 + 默认的参数适用于 9-track 磁带(6250 bpi), 所以如果要用高密度的磁带(最高可达 + 62,182 ftpi), 就不能用默认的参数, 而要另外指定参数。 + 这些默认值必须在命令行被修改以更好地利用当前磁带机的功能。 .rhosts - rdumprrestore 可以通过网络在另一 - 台计算机的磁带机上备份数据。这两个程序都是依靠 &man.rcmd.3; 和 - &man.ruserok.3; 来访问远程的磁带机。因此,运行备份的用户必须要有远程 - 主机的 .rhosts 访问权。rdump 和 - rrestore 的参数必须适用于远程主机(例如,当您从 FreeBSD 连到 - 一台 SUN 工作站 knomodo 去使用磁带机时,使用: + rdumprrestore + 可以通过网络在另一台计算机的磁带机上备份数据。 + 这两个程序都是依靠 &man.rcmd.3; 和 &man.ruserok.3; 来访问远程的磁带机。 + 因此,运行备份的用户必须要有远程主机的 .rhosts 访问权。 + rdumprrestore 的参数必须适用于远程主机 + 例如,当您从 FreeBSD 连到一台 SUN 工作站 knomodo 去使用磁带机时,使用: &prompt.root; /sbin/rdump 0dsbfu 54000 13000 126 komodo:/dev/nsa8 /dev/da0a 2>&1 要注意的是:必须检查您在使用 .rhosts 时的安全情况。 也可以通过使用 ssh 用一个更安全的方式来使用 dumprestore 通过 <application>ssh</application> 使用 <command>dump</command> &prompt.root; /sbin/dump -0uan -f - /usr | gzip -2 | ssh -c blowfish \ targetuser@targetmachine.example.com dd of=/mybigfiles/dump-usr-l0.gz 或使用 dump 的 built-in 方法, 设置环境变量 RSH 通过设置 <application>ssh</application> 环境变量 <envar>RSH</envar> 使用 <command>dump</command> &prompt.root; RSH=/usr/bin/ssh /sbin/dump -0uan -f targetuser@targetmachine.example.com:/dev/sa0 /usr <command>tar</command> 备份软件 tar &man.tar.1; 也同样是在第 6 版 AT&T UNIX (大约是 1975 前后) 出现的。 tar 对文件系统直接操作; 其作用是把文件和目录写入磁带。 tar 并不支持 &man.cpio.1; 所提供的全部功能, 但也不需要 cpio 所需要使用的诡异的命令行管道。 tar 在 FreeBSD 5.3 和更高版本中, 同时提供了 GNU tar 和默认的 bsdtar。 GNU 的版本可以通过 gtar 来使用。 它通过与 rdump 一样的语法来支持远程设备。 要 tar 到连接在名为 komodo 的 Sun 机器上的 Exabyte 磁带机, 可以使用: &prompt.root; /usr/bin/gtar cf komodo:/dev/nsa8 . 2>&1 您也可以让 bsdtar 通过管道和 rsh 将数据发送到远程的磁带机上。 &prompt.root; tar cf - . | rsh hostname dd of=tape-device obs=20b 如果您担心通过网络备份会有安全问题,应当使用 ssh , 而不是 rsh <command>cpio</command> backup software cpio &man.cpio.1; 是 &unix; 最早用来作文件交换的磁带机程序。它有执行字节 交换的选项,可以用几种不同的格式写入,并且可以将数据用管道传给其他程序。 cpio 没办法自动查找目录树内的文件列表,必须通过标准 输入 stdin 来指定。 cpio cpio 不支持通过网络的备份方式。可以使用 pipeline 和 rsh 来传送数据给远程的磁带机。 &prompt.root; for f in directory_list; do find $f >> backup.list done &prompt.root; cpio -v -o --format=newc < backup.list | ssh user@host "cat > backup_device" 这里的 directory_list 是要备份的目录列表, user@host 结合了将 要执行备份的用户名和主机名,backup_device 是写 入备份的设备(如 /dev/nsa0)。 <command>pax</command> backup software pax pax POSIX IEEE &man.pax.1; 是符合 IEEE/&posix; 标准的程序。多年来各种不同版本 的 tarcpio 间有些不兼容。 为了防止这种情况,并使其标准化,&posix; 出了这套新的工具程序。 pax 尝试可以读写各种 cpiotar 的格式,并可以自己增加新的格式。它的命令 集比 tar 更接近 cpio <application>Amanda</application> backup software Amanda Amanda Amanda (Advanced Maryland Network Disk Archiver) 并非单一的程序,而是一个客户机/服务器模式的备份系统 。一台 Amanda 服务器可以备份任意数量执行 Amanda 的客户机或是将连上 Amanda 服务器的计算机上的数据备份到一台磁带机上。一个常见的问题是,数据写入磁带机的时间将超 过取行数据的时间,而 Amanda 解决了这个问题。它使用一个 holding disk 来同时备份几个文件系统。 Amanda 建立 archive sets 的一组磁带,用来备份在 Amanda 的配置文件中所列出的完整的文件系统。 Amanda 配置文件提供完整的备份控制及 Amanda 产生的网络传输。 Amanda 可以使用上述任何一个设备程序来向磁带写入数据。Amanda 可以从 port 或 package 取得,它并非系统默认安装的。 Do Nothing 备份策略 Do nothing 不是一个程序,而是被广泛使用的备份策略。 不需要预算,不需要备份的计划表,全部都不用。如果您的数据发生了什么问题, 忽略它! 如果您的时间和数据不值得您做这些事,那么 Do nothing 将是最好的备份程序。要注意的是,&unix; 是相当好用的工具,您可能在几个月 内,就发现您已经收集了不少对您来说相当具有价值的文件和程序。 Do nothing 对于像 /usr/obj 和其他 可由您的计算机产生的文件来说,是最好的方法。例如这本手册包含有 HTML 或 &postscript; 格式的文件。这些文档格式是从 SGML 输入文件创建的。创建 HTML 或 &postscript; 格式的文件的备份就没有必要了。只要经常备份 SGML 文件就够了。 哪个备份程序最好? LISA 在&man.dump.8; 时期 Elizabeth D. Zwicky 测试了所有以上列出的备份程序。在各种各样怪异的文件系统中, dump 是您明智的选择。Elizabeth 建立起各种各样、 奇怪或常见的文件系统,并用各种备份程序,测试在各种文件系统上备份 及恢复数据。这些怪异之处包括:具有 holes 和一个 nulls block 的文件, 文件名具有有趣字符,无法读写的文件及设备,在备份时改变文件大小,在 备份时建立或删除的文件。她将结果刑在: LISA V in Oct. 1991. See torture-testing Backup and Archive Programs. 应急恢复程序 在出现灾难前 在遇到灾难前,只需要执行以下四个步骤: bsdlabel 第一,打出您的每个磁盘驱动器的磁盘标签 (例如: bsdlabel da0 | lpr),文件系统表, (/etc/fstab) ,以及所有启动信息, 并将其复制两份。 fix-it floppies 第二,确定遇到的情况时,用来启动及修复的软盘 (boot.flpfixit.flp) 具有您所有的设备代号。最简单的方法是用软盘启动,然后检查启动信息, 如果设备都被列出,并且可以正常使用,就可以跳到第三步。 否则,必须建立两张传统的可启动软盘,并包含: fdisk, bsdlabel, newfs, mount, 以及所有使用的 备份程序。这些程序必须被静态的连接。如果使用的是 dump, 那么这张软盘就必须包含 restore 第三,定期将数据备份到磁带。任何在上次备份后的改变都无法恢复。记得将 磁盘写保护。 第四,测试在第二步所建立的软盘及备份的磁带,将过程记录下来,并和这张 可启动的软盘和磁带放在一起。也许您在恢复时会想要,而这份记录将防止您破坏 您的磁带 (怎么说呢?因为您可能将 tar xvf /dev/sa0 打成 tar cvf /dev/sa0 而重写了备份磁带)。 为了安全,您可以每次都做两份备份磁带及一张启动磁盘,并将其中 一份备份磁带存放在其它地方。其它地方不是指同一栋办公大楼的地下室 (世贸中心的一些公司应该学到了一些教训),而是真的要让人的磁带离您 的的计算机远远的。 一个建立启动磁盘的 shell 脚本例子: /mnt/sbin/init gzip -c -best /sbin/fsck > /mnt/sbin/fsck gzip -c -best /sbin/mount > /mnt/sbin/mount gzip -c -best /sbin/halt > /mnt/sbin/halt gzip -c -best /sbin/restore > /mnt/sbin/restore gzip -c -best /bin/sh > /mnt/bin/sh gzip -c -best /bin/sync > /mnt/bin/sync cp /root/.profile /mnt/root chmod 500 /mnt/sbin/init chmod 555 /mnt/sbin/fsck /mnt/sbin/mount /mnt/sbin/halt chmod 555 /mnt/bin/sh /mnt/bin/sync chmod 6555 /mnt/sbin/restore # # create minimum file system table # cat > /mnt/etc/fstab < /mnt/etc/passwd < /mnt/etc/master.passwd < 出现灾难后 关键问题是: 您的硬件是否幸免于难? 由于已经做好了定期的备份工作, 因此并不需要担心软件的问题。 如果硬件已经损毁, 这些部分应该在尝试使用计算机之前换掉。 如果硬件还能用, 检查一下您的软盘。 如果使用定制的引导软盘, 启动单用户模式 (在 boot: 提示后输入 -s)。 跳过下面一段。 如果您使用 boot.flpfixit.flp 软盘, 请继续阅读。 将 boot.flp 软盘插到计算机的第一个软驱并启动机器。 此时, 最初的安装菜单将显示在屏幕上。 选择 Fixit--Repair mode with CDROM or floppy. 选项。 在得到提示后插入 fixit.flprestore 以及其他需要的程序, 可以在 /mnt2/rescue (对于 &os; 5.2 之前的版本, 则是 /mnt2/stand)。 分别恢复每一个文件系统 mount root partition bsdlabel newfs 试着 mount 上您的第一个磁盘的 root 分区(例如: mount /dev/da0a /mnt)。假如这个磁盘标签已经损坏,使用 bsdlabel 来重新分割并分配磁盘标签(利用您以前保留下来的数据)。使用 newfs 来建立文件系统,并重新挂上软盘读写的 root 分区 (mount -u -o rw /mnt)。然后使用备份程序及备份磁带来修复文件系统 (例如: restore vrf /dev/sa0)。最后 Unmount 这个文件系统 (例如: umount /mnt)。对于每个损坏的文件系统都重复一次。 当您的系统正常启动后,将您的数据备份到新的磁带。任何造成数据丢失的 的灾难都可能再次发生。现在花一些时间,也许可以使您免于下次的灾难。 * I Did Not Prepare for the Disaster, What Now? ]]> Marc Fonvieille Reorganized and enhanced by 网络、内存和 和以及映像文件为介质的虚拟文件系统 virtual disks 磁盘 虚拟 除了插在您计算机上的物理磁盘: 软盘、 CD、 硬盘驱动器, 等等之外, FreeBSD 还能识别一些其他的磁盘形式 - 虚拟磁盘 NFS Coda disks memory 这还包括, 如 网络文件系统 (Network File System) 和 Coda一类的网络文件系统、 内存以及映像文件为介质的虚拟文件系统。 随运行的 FreeBSD 版本不同, 用来创建和使用以映像文件介质文件系统和内存文件系统的工具也不尽相同。 系统会使用 &man.devfs.5; 来创建设备节点, 这对用户来说是透明的。 以映像文件为介质的文件系统 disks (磁盘) file-backed (采用文件作为介质) 在 FreeBSD 系统中, 可以用 &man.mdconfig.8; 程序来配置和启用内存磁盘, &man.md.4;。 要使用 &man.mdconfig.8;, 就需要在内核配置文件中添加 &man.md.4; 模块来支持它: device md &man.mdconfig.8; 命令支持三种类型的虚拟文件系统: 使用 &man.malloc.9;,来分配内存文件系统,内存文件系统作为文件或作为 备用的交换分区。一种使用方式是在文件中来挂载一个软盘和 CD 镜像。 将一个暨存的映像文件作为文件系统挂载: 使用 <command>mdconfig</command> 挂载已经存在的映像文件 &prompt.root; mdconfig -a -t vnode -f diskimage -u 0 &prompt.root; mount /dev/md0 /mnt 使用 &man.mdconfig.8; 来创建新的映像文件: 使用 <command>mdconfig</command> 将映像文件作为文件系统挂载 &prompt.root; dd if=/dev/zero of=newimage bs=1k count=5k 5120+0 records in 5120+0 records out &prompt.root; mdconfig -a -t vnode -f newimage -u 0 &prompt.root; bsdlabel -w md0 auto &prompt.root; newfs md0a /dev/md0a: 5.0MB (10224 sectors) block size 16384, fragment size 2048 using 4 cylinder groups of 1.25MB, 80 blks, 192 inodes. super-block backups (for fsck -b #) at: 160, 2720, 5280, 7840 &prompt.root; mount /dev/md0a /mnt &prompt.root; df /mnt Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/md0a 4710 4 4330 0% /mnt 如果没有通过 选项指定一个标识号 &man.mdconfig.8; 将使用 &man.md.4; 为它自动选择一个未用的设备标识号。 分配给它的标识名将被输出到标准输出设备, 其形式是与 md4 类似。 如果希望了解更多相关信息, 请参见联机手册 &man.mdconfig.8;。 &man.mdconfig.8; 功能很强大, 但在将映像文件作为文件系统挂载时, 仍需使用许多行的命令。 为此 FreeBSD 也提供了一个名为 &man.mdmfs.8; 的工具, 该程序使用 &man.mdconfig.8; 来配置 &man.md.4; 设备, 并用 &man.newfs.8; 在其上创建 UFS 文件系统, 然后用 &man.mount.8; 来完成挂载操作。 例如, 如果想创建和挂接像上面那样的文件系统映像, 只需简单地执行下面的步骤: 使用 <command>mdmfs</command> 命令配置和挂载一个映像文件为文件系统 &prompt.root; dd if=/dev/zero of=newimage bs=1k count=5k 5120+0 records in 5120+0 records out &prompt.root; mdmfs -F newimage -s 5m md0 /mnt &prompt.root; df /mnt Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/md0 4718 4 4338 0% /mnt 如果你使用没有加标识号的 选项, &man.mdmfs.8; 将使用 &man.md.4; 的自动标示号特性来自动为其 选择一个未使用的设备。更详细的 &man.mdmfs.8;,请参考联机手册。 以内存为介质的文件系统 disks (磁盘) 内存文件系统 一般来说, 在建立以内存为介质的文件系统时, 应使用 交换区作为介质 (swap backing)。 使用交换区作为介质, 并不意味着内存盘将被无条件地换出到交换区, 它只是表示将根据需要从可换出的内存池中分配内存。 此外, 也可以使用 &man.malloc.9; 创建以内存作为介质的文件系统。 不过在内存不足时, 这种方式可能引致系统崩溃。 用 <command>mdconfig</command> 创建新的内存盘设备 &prompt.root; mdconfig -a -t swap -s 5m -u 1 &prompt.root; newfs -U md1 /dev/md1: 5.0MB (10240 sectors) block size 16384, fragment size 2048 using 4 cylinder groups of 1.27MB, 81 blks, 192 inodes. with soft updates super-block backups (for fsck -b #) at: 160, 2752, 5344, 7936 &prompt.root; mount /dev/md1 /mnt &prompt.root; df /mnt Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/md1 4718 4 4338 0% /mnt 使用 <command>mdmfs</command> 来新建内存介质文件系统 &prompt.root; mdmfs -s 5m md2 /mnt &prompt.root; df /mnt Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/md2 4846 2 4458 0% /mnt 从系统中移除内存盘设备 磁盘 移除内存盘设备 当不再使用内存盘设备时, 应将其资源释放回系统。 第一步操作是卸下文件系统, 然后使用 &man.mdconfig.8; 把虚拟磁盘从系统中分离, 以释放资源。 例如, 要分离并释放所有 /dev/md4 使用的资源, 应使用命令: &prompt.root; mdconfig -d -u 4 mdconfig -l 命令可以列出关于配置 &man.md.4; 设备的信息。 Tom Rhodes Contributed by 文件系统快照 文件系统 快照 FreeBSD 提供了一个和 Soft Updates 关联的新功能: 文件系统快照 快照允许用户创建指定文件系统的映像,并把它们当做一个文件来对待。 快照文件必须在文件系统正在使用时创建,一个用户对每个文件系统创建的 快照不能大于20个。活动的快照文件被记录在超级块中,所以它们可以在系统 启动的时候一块进行挂接后摘掉。当一个快照不再需要时,可以使用标准的 &man.rm.1; 使用来使其删除。快照可以以任何顺序进行移除,但所有使用 的快照不可能同时进行移除,因为其它的快照将有可能互相引用一些块。 不可改的 文件标志, 是由 &man.mksnap.ffs.8; 在完成创建快照文件时设置的。 &man.unlink.1; 命令是一个特例, 以允许删除快照文件。 快照可以通过 &man.mount.8; 命令创建。 将文件系统 /var 的快照放到 /var/snapshot/snap 可以使用下面的命令: &prompt.root; mount -u -o snapshot /var/snapshot/snap /var 作为选择,你也可以使用 &man.mksnap.ffs.8; 来创建一个快照: &prompt.root; mksnap_ffs /var /var/snapshot/snap 可以查找文件系统中的快照文件 (例如 /var), 方法是使用 &man.find.1; 命令: &prompt.root; find /var -flags snapshot 当快照文件被创建好后,可以用于下面一些目的: 有些管理员用文件快照来进行备份, 因为快照可以被转移到 CD 或磁带上。 文件系统一致性检查程序 &man.fsck.8; 可以用来检查快照文件。 如果文件系统在挂接前是一致的, 则检查结果也一定是一致的 (也就是不会做任何修改)。 实际上这也正是后台 &man.fsck.8; 的操作过程。 在快照上运行 &man.dump.8; 程序。 dump 将返回包含文件系统和快照的时间戳。&man.dump.8; 也能够抓取快照,使用 标志可以首先创建快照, 完成 dump 映像之后再自动删除它。 用 &man.mount.8; 来挂接快照作为文件系统的一个冻结的镜像。 要 &man.mount.8; 快照 /var/snapshot/snap 运行: &prompt.root; mdconfig -a -t vnode -f /var/snapshot/snap -u 4 &prompt.root; mount -r /dev/md4 /mnt 现在你就可以看到挂接在 /mnt 目录下的 /var 文件系统的快照。 每一样东西都保存的像它创建时的状态一样。 唯一例外的是更早的快照文件将表现为长度为 0 的文件。 用完快照文件之后可以把它卸下,使用: &prompt.root; umount /mnt &prompt.root; mdconfig -d -u 4 想了解更多关于 和 文件系统快照的信息, 包括技术说明, 可以访问 Marshall Kirk McKusick 的 WWW 站点 文件系统配额 accounting disk space disk quotas 配额是操作系统的一个可选的功能, 它允许管理员以文件系统为单元, 限制分派给用户或组成员所使用的磁盘空间大小或是使用的总文件数量。 这经常被用于那些分时操作的系统上, 对于这些系统而言, 通常希望限制分派到每一个用户或组的资源总量, 从而可以防止某个用户占用所有可用的磁盘空间。 配置系统来启用磁盘配额 在决定使用磁盘配额前,确信磁盘配额已经在内核中配置好了。只要在在内核 中配置文件中添加下面一行就行了: options QUOTA 在默认情况下 GENERIC 内核是不会启用这个功能的, 所以必须配置、重建和安装一个定制的内核。请参考 FreeBSD 内核配置 这章了解更多有关内核配置的信息。 接下来,需要在 /etc/rc.conf 中启用磁盘配额。可以 通过添加下面这行来完成: enable_quotas="YES" disk quotas checking 为了更好的控制配额时的启动,还有另外一个可配置的变量。通常 启动时,集成在每个文件系统上的配额会被配额检查程序 &man.quotacheck.8; 自动检查。配额检查功能能够确保在配额数据库中 的数据正确地反映了文件系统的数 据情况。这是一个很耗时间的处理进程,它会影响系统的启动时间。如果 想跳过这一步,可以在文件 /etc/rc.conf 加入 下面这一行来达到目的: check_quotas="NO" 最后,要编辑 /etc/fstab 文件,以在每一个 文件系统基础上雇用磁盘配额。这是启用用户和组配额,或同时启用用户 和组配额的地方。 要在一个文件系统上启用每个用户的配额,可以在 /etc/fstab 里添加 选项在要雇用配额文件的系统上。例如: /dev/da1s2g /home ufs rw,userquota 1 2 同样的,要启用组配额,使用 选项来代替 选项。要同时启用用户和组配额,可以这样做: /dev/da1s2g /home ufs rw,userquota,groupquota 1 2 默认情况下,配额文件是存放在文件系统的以 quota.userquota.group 命名的根目录下。可以查看 &man.fstab.5; 联机手册了解更多信息。 尽管联机手册 &man.fstab.5; 提到, 可以为配额文件指定其他的位置, 但并不推荐这样做, 因为不同的配额工具并不一定遵循此规则。 到这儿,可以用新内核重新启动系统。 /etc/rc 将自动 运行适当的命令来创建最初的配额文件,所以并不需要手动来创建任何零长度的配额 文件。 在通常的操作过程中,并不要求手动运行 &man.quotacheck.8;、 &man.quotaon.8;, 或 &man.quotaoff.8; 命令,然而可能需要阅读与他们的操作 相似的联机手册。 设置配额限制 disk quotas limits 一旦您配置好了启用配额的系统,可以检查一下它们是真的有用。 可以这样做: &prompt.root; quota -v 您应该能够看到一行当前正在使用的每个文件系统启用的磁盘配额 使用情况的摘要信息。 现在可以使用 &man.edquota.8; 命令准备启用配额限制。 有几个有关如何强制限制用户或组可以分配到的磁盘空间大小的选项。 您可以限制磁盘存储块的配额, 或文件的数量, 甚至同时限制两者。 这些限制最终可分为两类: 硬限制和软限制。 硬性限制 硬性限制是一种不能越过的限制。 一旦用户达到了系统指定的硬性限制, 他就无法在对应的文件系统分配到更多的资源。 例如, 如果文件系统上分给用户的硬性限制是 500 KB, 而现在已经用掉了 490 KB, 那么这个用户最多还能再分配 10 KB 的空间。 换言之, 如果这时试图再分配 11 KB, 则会失败。 软性限制 而与此相反, 软性限制在一段时间内是允许越过的。 这段时间也称为宽限期, 其默认值是一周。 如果一个用户延缓时间太长的话,软限制将会变成硬限制, 而继续分配磁盘空间的操作将被拒绝。 当用户占用的空间回到软性限制值以下时, 宽限期将重新开始计算。 下面是一个运行 &man.edquota.8; 时看到的例子。当 &man.edquota.8; 命令被调用时,会被转移进 EDITOR 环境变量指派的编辑 器中,允许编辑配额限制。如果环境变量没有设置,默认在 vi 编辑器上进行。 &prompt.root; edquota -u test Quotas for user test: /usr: kbytes in use: 65, limits (soft = 50, hard = 75) inodes in use: 7, limits (soft = 50, hard = 60) /usr/var: kbytes in use: 0, limits (soft = 50, hard = 75) inodes in use: 0, limits (soft = 50, hard = 60) 在每一个启用了磁盘配额的文件系统上,通常会看到两行。一行是 block 限制,另一行是 inode 限制。简单地改变要修改的配额限制的值。 例如,提高这个用户软限制的数值到 500 ,硬限制到 600 : /usr: kbytes in use: 65, limits (soft = 50, hard = 75) to: /usr: kbytes in use: 65, limits (soft = 500, hard = 600) 当离开编辑器的时候,新的配额限制设置将会被保存。 有时,在 UIDs 的范围上设置配额限制是非常必要的。这可以通过在 &man.edquota.8; 命令后面加上 选项来完成。首先, 给用户分配所需要的配额限制,然后运行命令 edquota -p protouser startuid-enduid。例如,如果 用户 test 已经有了所需要的配额限制,下面的命令 可以被用来复制那些 UIDs 为10,000 到 19,999 的配额限制: &prompt.root; edquota -p test 10000-19999 更多细节请参考 &man.edquota.8; 联机手册。 检查配额限制和磁盘使用 disk quotas checking 既可以使用 &man.quota.1; 也可以使用 &man.repquota.8; 命令来检查 配额限制和磁盘使用情况。 &man.quota.1; 命令能够检查单个用户和组的配置 使用情况。只有超级用户才可以检查其它用户的配额和磁盘使用情况。 &man.repquota.8; 命令可以用来了解所有配额和磁盘的使用情况。 下面是一个使用 quota -v 命令后的输出情况: Disk quotas for user test (uid 1002): Filesystem usage quota limit grace files quota limit grace /usr 65* 50 75 5days 7 50 60 /usr/var 0 50 75 0 50 60 宽限期 前面以 /usr 作为例子。 此用户目前已经比软限制 50 KB 超出了 15 KB, 还剩下 5 天的宽限期。 请注意, 星号 * 说明用户已经超出了其配额限制。 通常, 如果用户没有使用文件系统上的磁盘空间, 就不会在 &man.quota.1; 命令的输出中显示, 即使已经为那个用户指定了配额。 而使用 选项则会显示它们, 例如前面例子中的 /usr/var 通过 NFS 使用磁盘配额 NFS 配额能够在 NFS 服务器上被配额子系统强迫使用。在 NFS 客户端, &man.rpc.rquotad.8; 命令可以使用 quota 信息用于 &man.quota.1; 命令, 可以允许用户查看它们的 quota 统计信息。 可以这样在 /etc/inetd.conf 中启用 rpc.rquotad rquotad/1 dgram rpc/udp wait root /usr/libexec/rpc.rquotad rpc.rquotad 现在重启 inetd &prompt.root; /etc/rc.d/inetd restart Lucky Green Contributed by
shamrock@cypherpunks.to
加密磁盘分区 disks encrypting FreeBSD 提供了极好的数据保护措施,防止未受权的数据访问。 文件权限和强制访问控制(MAC)(看 ) 可以帮助预防在操作系统处于运行状态和计算机加电时未受权的第三方访问数据。 但是,和操作系统强制受权不相关的是,如果黑客有物理上访问计算机的可能, 那他就可以简单的把计算机的硬件安装到另一个系统上复制出敏感的数据。 无论攻击者如何取得停机后的硬件或硬盘驱动器本身, &os; GEOM Based Disk Encryption (基于 GEOM 的磁盘加密, gbde)geli 加密子系统都能够保护计算机上的文件系统数据, 使它们免受哪怕是训练有素的攻击者获得有用的资源。 与那些只能加密单个文件的笨重的加密方法不同, gbdegeli 能够透明地加密整个文件系统。 明文数据不会出现在硬盘的任何地方。 使用 <application>gbde</application> 对磁盘进行加密 成为 <username>root</username> 配置 gbde 需要超级用户的权力。 &prompt.user; su - Password: 在内核配置文件中添加对 &man.gbde.4; 的支持 在您的内核配置中加入下面一行: options GEOM_BDE 按照 所进行的介绍重新编译并安装内核。 重新引导进入新的内核。 另一种无需重新编译内核的方法, 是使用 kldload 来加载 &man.gbde.4;: &prompt.root; kldload geom_bde 准备加密盘 下面这个例子假设您添加了一个新的硬盘在您的系统并将拥有一个单独的加密分区。 这个分区将挂接在 /private目录下。 gbde 也可以用来加密 /home/var/mail, 但是这需要更多的复杂命令来执行。 添加新的硬盘 添加新的硬盘到系统中可以查看在 中的说明。 这个例子的目的是说明一个新的硬盘分区已经添加到系统中如: /dev/ad4s1c。在例子中 /dev/ad0s1* 设备代表系统中存在的标准 FreeBSD 分区。 &prompt.root; ls /dev/ad* /dev/ad0 /dev/ad0s1b /dev/ad0s1e /dev/ad4s1 /dev/ad0s1 /dev/ad0s1c /dev/ad0s1f /dev/ad4s1c /dev/ad0s1a /dev/ad0s1d /dev/ad4 创建一个目录来保存 gbde Lock 文件 &prompt.root; mkdir /etc/gbde gbde lock 文件包含了 gbde 需要访问的加密分区的信息。 没有 lock 文件, gbde 将不能解密包含在加密分区上的数据。 每个加密分区使用一个独立的 lock 文件。 初始化 gbde 分区 一个 gbde 分区在使用前必须被初始化, 这个初始化过程只需要执行一次: &prompt.root; gbde init /dev/ad4s1c -i -L /etc/gbde/ad4s1c.lock &man.gbde.8; 将打开您的编辑器, 提示您去设置在一个模板文件中的配置变量。 使用 UFS1 或 UFS2,设置扇区大小为 2048: $FreeBSD: src/sbin/gbde/template.txt,v 1.1 2002/10/20 11:16:13 phk Exp $ # # Sector size is the smallest unit of data which can be read or written. # Making it too small decreases performance and decreases available space. # Making it too large may prevent filesystems from working. 512 is the # minimum and always safe. For UFS, use the fragment size # sector_size = 2048 [...] &man.gbde.8; 将让您输入两次用来加密数据的密钥短语。 两次输入的密钥必须相同。 gbde 保护您数据的能力依靠您选择输入的密钥的质量。 这个提示教您怎样选择一个安全易记的密钥短语, 请看 Diceware Passphrase 网站。 gbde init 命令为您的 gbde 分区创建了一个 lock 文件, 在这个例子中存储在 /etc/gbde/ad4s1c.lock中。 gbde lock 文件必须使用 .lock 扩展名才能够被 /etc/rc.d/gbde 启动脚本正确识别。 gbde lock 文件 必须 和加密分区上的内容同时备份。 如果发生只有 lock 文件遭到删除的情况时, 就没有办法确定 gbde 分区上的数据是否是解密过的。 另外, 如果没有 lock 文件, 即使磁盘的合法主人, 不经过大量细致的工作也无法访问加密分区上的数据, 而这是在设计 &man.gbde.8; 时完全没有考虑过的。 把加密分区和内核进行关联 &prompt.root; gbde attach /dev/ad4s1c -l /etc/gbde/ad4s1c.lock 在加密分区的初始化过程中您将被要求提供一个密码短语。 新的加密设备将在 /dev 中显示为 /dev/device_name.bde &prompt.root; ls /dev/ad* /dev/ad0 /dev/ad0s1b /dev/ad0s1e /dev/ad4s1 /dev/ad0s1 /dev/ad0s1c /dev/ad0s1f /dev/ad4s1c /dev/ad0s1a /dev/ad0s1d /dev/ad4 /dev/ad4s1c.bde 在加密设备上创建文件系统 当加密设备和内核进行关联后, 您就可以使用 &man.newfs.8; 在此设备上创建文件系统, 使用 &man.newfs.8; 来初始化一个 UFS2 文件系统比初始化一个 UFS1 文件系统还要快,摧荐使用 选项。 &prompt.root; newfs -U -O2 /dev/ad4s1c.bde &man.newfs.8; 命令必须在一个 gbde 分区上执行, 这个分区通过一个存在的 *.bde 设备名进行标识。 挂接加密分区 为加密文件系统创建一个挂接点。 &prompt.root; mkdir /private 挂接加密文件系统。 &prompt.root; mount /dev/ad4s1c.bde /private 校验加密文件系统是否有效 加密的文件系统现在对于 &man.df.1; 应该可见并可以使用。 &prompt.user; df -H Filesystem Size Used Avail Capacity Mounted on /dev/ad0s1a 1037M 72M 883M 8% / /devfs 1.0K 1.0K 0B 100% /dev /dev/ad0s1f 8.1G 55K 7.5G 0% /home /dev/ad0s1e 1037M 1.1M 953M 0% /tmp /dev/ad0s1d 6.1G 1.9G 3.7G 35% /usr /dev/ad4s1c.bde 150G 4.1K 138G 0% /private 挂接已有的加密文件系统 每次系统启动后, 在使用加密文件系统前必须和内核重新进行关联, 校验错误和再次挂接。使用的命令必须由 root用户来执行。 关联 gbde 分区到内核 &prompt.root; gbde attach /dev/ad4s1c -l /etc/gbde/ad4s1c.lock 接下来系统将提示您输入在初始化加密的 gbde 分区时所用的密码短语。 校验文件系统错误 加密文件系统不能列在 /etc/fstab 文件中进行自动加载, 在加载前必须手动运行 &man.fsck.8; 命令对文件系统进行错误检测。 &prompt.root; fsck -p -t ffs /dev/ad4s1c.bde 挂接加密文件系统 &prompt.root; mount /dev/ad4s1c.bde /private 加密后的文件系统现在可以有效使用。 自动挂接加密分区 可以创建脚本来自动地附加、 检测, 并挂接加密分区, 然而, 处于安全考虑, 这个脚本不应包含 &man.gbde.8; 密码。 因而, 我们建议这类脚本在控制台或通过 &man.ssh.1; 执行并要求用户输入口令。 除此之外, 系统还提供了一个 rc.d 脚本。 这个脚本的参数可以通过 &man.rc.conf.5; 来指定, 例如: gbde_autoattach_all="YES" gbde_devices="ad4s1c" gbde_lockdir="/etc/gbde" 在启动时将要求输入 gbde 的口令。 在输入正确的口令之后, gbde 加密分区将被自动挂接。 对于将 gbde 用在笔记本电脑上时, 这就很有用了。 gbde 提供的密码学保护 &man.gbde.8; 采用 CBC 模式的 128-位 AES 来加密扇区数据。 磁盘上的每个扇区都采用不同的 AES 密钥来加密。 要了解关于 gbde 的密码学设计, 包括扇区密钥如何从用户提供的口令字中生成等细节, 请参考 &man.gbde.4;。 兼容性问题 &man.sysinstall.8; 是和 gbde 加密设备不兼容的。 在启动 &man.sysinstall.8; 时必须将 *.bde 设备和内核进行分离,否则在初始化探测设备时将引起冲突。 与加密设备进行分离在我们的例子中使用如下的命令: &prompt.root; gbde detach /dev/ad4s1c 还需要注意的是, 由于 &man.vinum.4; 没有使用 &man.geom.4; 子系统, 因此不能同时使用 gbdevinum 卷。 Daniel Gerzo 撰写者 使用 <command>geli</command> 对磁盘进行加密 从 &os; 6.0 开始提供了一个新的密码学 GEOM class — geli。 它目前由 &a.pjd; 开发。 Geli 工具与 gbde 不同; 它提供了一些不同的功能, 并采用了不同的方式来进行密码学运算。 &man.geli.8; 最重要的功能包括: 使用了 &man.crypto.9; 框架 — 如果系统中有加解密硬件加速设备, 则 geli 会自动加以利用。 支持多种加密算法 (目前支持 AES、 Blowfish, 以及 3DES)。 允许对根分区进行加密。 在系统启动时, 将要求输入用于加密根分区的口令。 允许使用两个不同的密钥 (例如, 一个 个人密钥 和一个 公司密钥)。 geli 速度很快 — 它只进行简单的扇区到扇区的加密。 允许备份和恢复主密钥。 当用户必须销毁其密钥时, 仍然可以通过从备份中恢复密钥来存取数据。 允许使用随机的一次性密钥来挂接磁盘 — 这对于交换区和临时文件系统非常有用。 更多 geli 功能介绍可以在 &man.geli.8; 联机手册中找到。 下面的步骤介绍了如何启用 &os; 内核中的 geli 支持, 并解释了如何创建新和使用 geli 加密 provider。 要使用 geli, 您必须运行 &os; 6.0-RELEASE 或更新版本。 由于需要修改内核, 因此您还需要拥有超级用户权限。 在内核中加入 <command>geli</command> 支持 在内核配置文件中加入下面两行: options GEOM_ELI device crypto 按照 介绍的步骤重新编译并安装内核。 另外, geli 也可以在系统引导时加载。 这是通过在 /boot/loader.conf 中增加下面的配置来实现的: geom_eli_load="YES" &man.geli.8; 现在应该已经为内核所支持了。 生成主密钥 下面的例子讲描述如何生成密钥文件, 它将作为主密钥 (Master Key) 的一部分, 用于挂接到 /private 的加密 provider。 这个密钥文件将提供一些随机数据来加密主密钥。 同时, 主密钥也会使用一个口令字来保护。 Provider 的扇区尺寸为 4kB。 此外, 这里的讨论将介绍如何挂载 geli provider, 在其上创建文件系统, 如何挂接并在其上工作, 最后将其卸下。 建议您使用较大的扇区尺寸 (例如 4kB), 以获得更好的性能。 主密钥将由口令字保护, 而密钥文件的数据来源则将是 /dev/random。 我们称之为 provider 的 /dev/da2.eli 的扇区尺寸将是 4kB。 &prompt.root; dd if=/dev/random of=/root/da2.key bs=64 count=1 &prompt.root; geli init -s 4096 -K /root/da2.key /dev/da2 Enter new passphrase: Reenter new passphrase: 同时使用口令字和密钥文件并不是必须的; 您也可以只使用其中的一种来加密主密钥。 如果密钥文件写作 -, 则表示使用标准输入。 下面是关于如何使用多个密钥文件的例子: &prompt.root; cat keyfile1 keyfile2 keyfile3 | geli init -K - /dev/da2 将 provider 与所生成的密钥关联 &prompt.root; geli attach -k /root/da2.key /dev/da2 Enter passphrase: 新的明文设备将被命名为 /dev/da2.eli &prompt.root; ls /dev/da2* /dev/da2 /dev/da2.eli 创建新的文件系统 &prompt.root; dd if=/dev/random of=/dev/da2.eli bs=1m &prompt.root; newfs /dev/da2.eli &prompt.root; mount /dev/da2.eli /private 现在加密的文件系统应该已经可以被 &man.df.1; 看到, 并处于可用状态了: &prompt.root; df -H Filesystem Size Used Avail Capacity Mounted on /dev/ad0s1a 248M 89M 139M 38% / /devfs 1.0K 1.0K 0B 100% /dev /dev/ad0s1f 7.7G 2.3G 4.9G 32% /usr /dev/ad0s1d 989M 1.5M 909M 0% /tmp /dev/ad0s1e 3.9G 1.3G 2.3G 35% /var /dev/da2.eli 150G 4.1K 138G 0% /private 卸下卷并断开 provider 一旦在加密分区上的工作完成, 并且不再需要 /private 分区, 就应考虑将其卸下并将 geli 加密分区从内核上断开。 &prompt.root; umount /private &prompt.root; geli detach da2.eli 关于如何使用 &man.geli.8; 的更多信息, 可以在其联机手册中找到。 使用 <filename>geli</filename> <filename>rc.d</filename> 脚本 geli 提供了一个 rc.d 脚本, 它可以用于简化 geli 的使用。 通过 &man.rc.conf.5; 配置 geli 的方法如下: geli_devices="da2" geli_da2_flags="-p -k /root/da2.key" 这将把 /dev/da2 配置为一个 geli provider, 其主密钥文件位于 /root/da2.key, 而 geli 在连接 provider 时将不使用口令字 (注意只有在 geli init 阶段使用了 才可以这样做)。 系统将在关闭之前将 geli provider 断开。 关于如何配置 rc.d 的详细信息可以在使用手册的 rc.d 一节中找到。
Christian Brüffer 原作 对交换区进行加密 swap (交换区) encrypting (加密) 从 &os; 5.3-RELEASE 开始, &os; 提供了易于配置的交换区加密机制。 随所用的 &os; 版本, 可用的配置选项会有所不同, 而配置方法也会有一些差异。 从 &os; 6.0-RELEASE 开始, 已经可以使用 &man.gbde.8; 和 &man.geli.8; 两种加密系统来进行交换区的加密操作了。 在更早的版本中, 则只提供了 &man.gbde.8;。 前面所说的这两种加密系统, 都用到了 encswap 这个 rc.d 脚本。 在前面的小节 如何加密磁盘分区 中, 已经就不同的加密系统之间的区别进行了简单的讨论。 为什么需要对交换区进行加密? 与加密磁盘分区类似, 加密交换区有助于保护敏感信息。 为此, 我们不妨考虑一个需要处理敏感信息的程序, 例如, 它需要处理口令。 如果这些口令一直保持在物理内存中, 则一切相安无事。 然而, 如果操作系统开始将内存页换出到交换区, 以便为其他应用程序腾出内存时, 这些口令就可能以未加密的形式写到磁盘上, 并为攻击者所轻易获得。 加密交换区能够有效地解决这类问题。 准备 在本节余下的部分中, 我们约定使用 ad0s1b 作为交换区。 到目前为止, 交换区仍是未加密的。 很可能其中已经存有明文形式的口令或其他敏感数据。 要纠正这一问题, 首先应使用随机数来覆盖交换分区的数据: &prompt.root; dd if=/dev/random of=/dev/ad0s1b bs=1m 使用 &man.gbde.8; 来加密交换区 如果使用 &os; 6.0-RELEASE 或更新的版本, 则 /etc/fstab 中与交换区对应的行中, 设备名应追加 .bde 后缀: # Device Mountpoint FStype Options Dump Pass# /dev/ad0s1b.bde none swap sw 0 0 对于 &os; 6.0-RELEASE 之前的版本, 还需要在 /etc/rc.conf 中加入: gbde_swap_enable="YES" 使用 &man.geli.8; 来加密分区 另一种方法是使用 &man.geli.8; 来达到加密交换区的目的, 其过程与使用 &man.gbde.8; 大体相似。 此时, 在 /etc/fstab 中交换区对应的行中, 设备名应追加 .eli 后缀: # Device Mountpoint FStype Options Dump Pass# /dev/ad0s1b.eli none swap sw 0 0 &man.geli.8; 默认情况下使用密钥长度为 256-位的 AES 加密算法。 当然, 这些默认值是可以通过 /etc/rc.conf 中的 geli_swap_flags 选项来修改的。 下面的配置表示让 rc.d 脚本 encswap 创建一个 &man.geli.8; 交换区, 在其上使用密钥长度为 128-位 的 Blowfish 加密算法, 4 kilobytes 的扇区尺寸, 并采用 最后一次关闭时卸下 的策略: geli_swap_flags="-e blowfish -l 128 -s 4096 -d" For systems prior to &os; 6.2-RELEASE, use the following line: geli_swap_flags="-a blowfish -l 128 -s 4096 -d" 请参见 &man.geli.8; 联机手册中关于 onetime 命令的说明, 以了解其他可用的选项。 验证所作的配置能够发挥作用 在重启系统之后, 就可以使用 swapinfo 命令来验证加密交换区是否已经在正常运转了。 如果使用了 &man.gbde.8;, 则: &prompt.user; swapinfo Device 1K-blocks Used Avail Capacity /dev/ad0s1b.bde 542720 0 542720 0% 如果使用了 &man.geli.8;, 则: &prompt.user; swapinfo Device 1K-blocks Used Avail Capacity /dev/ad0s1b.eli 542720 0 542720 0%
diff --git a/zh_CN.GB2312/books/handbook/dtrace/chapter.sgml b/zh_CN.GB2312/books/handbook/dtrace/chapter.sgml index f391d34443..fbd429f049 100644 --- a/zh_CN.GB2312/books/handbook/dtrace/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/dtrace/chapter.sgml @@ -1,370 +1,370 @@ Tom Rhodes Written by - DTrace + &dtrace; 概述 - DTrace + &dtrace; - DTrace support - DTrace + &dtrace; support + &dtrace; - DTrace,也称为动态跟踪,是由 &sun; + &dtrace;,也称为动态跟踪,是由 &sun; 开发的一个用来在生产和试验性生产系统上找出系统瓶颈的工具。 在任何情况下它都不是一个调试工具, 而是一个实时系统分析寻找出性能及其他问题的工具。 - DTrace 是个特别好的分析工具,带有大量的帮助诊断系统问题的特性。 + &dtrace; 是个特别好的分析工具,带有大量的帮助诊断系统问题的特性。 还可以使用预先写好的脚本利用它的功能。 - 用户也可以通过使用 DTrace D 语言创建他们自己定制的分析工具, + 用户也可以通过使用 &dtrace; D 语言创建他们自己定制的分析工具, 以满足特定的需求。 在阅读了这一章节之后,你将了解: - DTrace 是什么,它提供了些哪些特性。 + &dtrace; 是什么,它提供了些哪些特性。 - DTrace 在 &solaris; 与 &os; 上的实现的差别。 + &dtrace; 在 &solaris; 与 &os; 上的实现的差别。 - 如何在 &os; 上开启和使用 DTrace。 + 如何在 &os; 上开启和使用 &dtrace;。 在阅读这一章节之前,你应该了解: 了解 &unix; 和 &os; 的基本知识 ()。 熟悉基本的内核配置/编译 (). 熟悉 &os; 有关的安全知识 ()。 了解如何获取和重新编译 &os; 源代码 - ()。 + ()。 这项特性目前仍被认为是试验性的。 有些选项功能性缺失,另有一些可能还无法运行。最终, 这个特性会适合用于生产,届时这篇文档也会做些适当的修改。 实现上的差异 - 虽然 &os; 上的 DTrace 与 &solaris; 上的非常相似, + 虽然 &os; 上的 &dtrace; 与 &solaris; 上的非常相似, 在继续深入之前我们需要说明一下存在的差异。 - 用户首先会注意到的便是 &os; 上的 DTrace 需要明确的被启用。 - DTrace 相关的内核选项和模块必须开启后才能正常工作。 + 用户首先会注意到的便是 &os; 上的 &dtrace; 需要明确的被启用。 + &dtrace; 相关的内核选项和模块必须开启后才能正常工作。 稍后我们会作详细介绍。 有一个 DDB_CTF 内核选项用来开启从内核与内核模块加载 CTF 数据。 CTF 是 &solaris; Compact C Type Format 封装了类似于 DWARF 和 venerable stabs 简化的调试信息。CTF 数据是由 ctfconvertctfmerge 工具加入二进制文件的。ctfconvert 工具分析由编译器生成的 DWARF 调试 ELF section, ctfmerge 合并目标文件的 CTF ELF section 到可执行文件或共享库。更多关于在启用 &os; 内核上启用此项的详细内容即将完成。 比起 &solaris;, &os; 有几个不同提供器。 最值得注意的时 dtmalloc 提供器, 可以让你根据类型追踪 &os; 内核中的 malloc() - 只有 root 可以使用 &os; 上的 DTrace。 + 只有 root 可以使用 &os; 上的 &dtrace;。 这是由系统安全上的差异造成的,&solaris; 提供了一些 &os; 上还为实现的低层的安全检查。同样, /dev/dtrace/dtrace 也被严格的限制为仅供 root 用户访问。 - 最后,DTrace 为 &sun; CDDL + 最后,&dtrace; 为 &sun; CDDL 许可下发布的软件。随 &os; 发行的 Common Development and Distribution License 可以在查阅 /usr/src/cddl/contrib/opensolaris/OPENSOLARIS.LICENSE 或者通过 查看在线版本。 - 这个许可表示带有 DTrace 选项的 &os; 内核仍为 + 这个许可表示带有 &dtrace; 选项的 &os; 内核仍为 BSD 许可;然而以二进制发布模块, 或者加载二进制模块则需遵守 CDDL - 启用 DTrace 支持 + 启用 &dtrace; 支持 - 在内核配置文件中加入以下几行来开启对 DTrace 的支持: + 在内核配置文件中加入以下几行来开启对 &dtrace; 的支持: options KDTRACE_HOOKS options DDB_CTF 使用 AMD64 架构的需要在内核配置文件中加入如下这行: options KDTRACE_FRAME 此选项提供了对 FBT 特性的支持。 - DTrace 可以在没有此选项的情况下正常工作, + &dtrace; 可以在没有此选项的情况下正常工作, 但是函数边界跟踪便会有所限制。 所有的源代码都必须重新使用 CTF 选项编译安装。重新编译 &os; 源代码可以通过以下的命令完成: &prompt.root; cd /usr/src &prompt.root; make WITH_CTF=1 kernel 系统需要重新启动。 在重新启动和新内核载入内存之后,需要添加 Korn shell - 的支持。因为 DTrace 工具包有一些工具是由 ksh + 的支持。因为 &dtrace; 工具包有一些工具是由 ksh 写的。安装 shells/ksh93。 同样也可以通过 shells/pdksh 或者 shells/mksh 使用这些工具。 最后是获得最新的 DTrace 工具包。 当前版本可以通过下面的链接找到 。 这个工具包含有一个安装机制,尽管如此,并不需要安装便可使用它们。 - 使用 DTrace + 使用 &dtrace; - 在使用 DTrace 的功能之前,DTrace 设备必须存在。 + 在使用 &dtrace; 的功能之前,&dtrace; 设备必须存在。 使用如下的命令装载此设备: &prompt.root; kldload dtraceall - DTrace 支持现在应该可以使用了。 + &dtrace; 支持现在应该可以使用了。 管理员现在可以使用如下的命令查看所有的探测器: &prompt.root; dtrace -l | more 所有的输出都传递给 more 工具, - 因为它们会很快超出屏幕的显示区域。此时,DTrace + 因为它们会很快超出屏幕的显示区域。此时,&dtrace; 应该被认为是能够正常工作的了。现在是该考察工具包的时候了。 - 工具包是实现写好的一堆脚本,与 DTrace 一起运行来收集系统信息。 + 工具包是实现写好的一堆脚本,与 &dtrace; 一起运行来收集系统信息。 有脚本用来检查已打开的文件,内存,CPU 使用率和许多东西。使用如下的命令解开脚本: &prompt.root; gunzip -c DTraceToolkit* | tar xvf - 使用 cd 命令切换到那个目录, 并修改所有文件的可执行权限,把那些名字小写的文件权限改为 755 所有这些脚本都需要修改它们的内容。那些指向 /usr/bin/ksh 需要修改成 /usr/local/bin/ksh,另外使用 /usr/bin/sh 需要变更为 /bin/sh,最后还有使用 /usr/bin/perl 的需要变更为 /usr/local/bin/perl - 此刻还需谨慎提醒一下读者 &os; 的 DTrace 支持仍是 + 此刻还需谨慎提醒一下读者 &os; 的 &dtrace; 支持仍是 不完整的试验性 的。 这些脚本中的大多数都无法运行,因为它们过于针对 &solaris; 或者使用了目前还不支持的探测器。 - 在撰写这篇文章的时候,DTrace 工具包中只有两个脚本在 + 在撰写这篇文章的时候,&dtrace; 工具包中只有两个脚本在 &os; 上是完全支持的: hotkernelprocsystime 脚本。这两个脚本便是我们下一部分将要探讨的: hotkernel 被设计成验明哪个函数占用了内核时间。 正常运行的话,它将生成类似以下的输出: &prompt.root; ./hotkernel Sampling... Hit Ctrl-C to end. 系统管理员必须使用 CtrlC 组合键停止这个进程。 紧接着中止之后,脚本便会一张内核函数与测定时间的列表, 使用增量排序输出: kernel`_thread_lock_flags 2 0.0% 0xc1097063 2 0.0% kernel`sched_userret 2 0.0% kernel`kern_select 2 0.0% kernel`generic_copyin 3 0.0% kernel`_mtx_assert 3 0.0% kernel`vm_fault 3 0.0% kernel`sopoll_generic 3 0.0% kernel`fixup_filename 4 0.0% kernel`_isitmyx 4 0.0% kernel`find_instance 4 0.0% kernel`_mtx_unlock_flags 5 0.0% kernel`syscall 5 0.0% kernel`DELAY 5 0.0% 0xc108a253 6 0.0% kernel`witness_lock 7 0.0% kernel`read_aux_data_no_wait 7 0.0% kernel`Xint0x80_syscall 7 0.0% kernel`witness_checkorder 7 0.0% kernel`sse2_pagezero 8 0.0% kernel`strncmp 9 0.0% kernel`spinlock_exit 10 0.0% kernel`_mtx_lock_flags 11 0.0% kernel`witness_unlock 15 0.0% kernel`sched_idletd 137 0.3% 0xc10981a5 42139 99.3% 这个脚本也能与内核模块一起工作。要使用此特性, 用 标志运行脚本: &prompt.root; ./hotkernel -m Sampling... Hit Ctrl-C to end. ^C MODULE COUNT PCNT 0xc107882e 1 0.0% 0xc10e6aa4 1 0.0% 0xc1076983 1 0.0% 0xc109708a 1 0.0% 0xc1075a5d 1 0.0% 0xc1077325 1 0.0% 0xc108a245 1 0.0% 0xc107730d 1 0.0% 0xc1097063 2 0.0% 0xc108a253 73 0.0% kernel 874 0.4% 0xc10981a5 213781 99.6% procsystime 脚本捕捉并打印给定 PID 的系统调用时间。 在下面的例子中,新生成了一个 /bin/csh 实例。procsystime 执行后则等待在新运行的 csh 上键入一些命令。 这是测试的结果: &prompt.root; ./procsystime -n csh Tracing... Hit Ctrl-C to end... ^C Elapsed Times for processes csh, SYSCALL TIME (ns) getpid 6131 sigreturn 8121 close 19127 fcntl 19959 dup 26955 setpgid 28070 stat 31899 setitimer 40938 wait4 62717 sigaction 67372 sigprocmask 119091 gettimeofday 183710 write 263242 execve 492547 ioctl 770073 vfork 3258923 sigsuspend 6985124 read 3988049784 正如显示的那样,read 系统调用似乎使用了最多的纳秒单位时间, getpid() 系统调用使用了最少的时间。 D 语言 - DTrace 工具包包括了很多由 DTrace 特殊语言写成的脚本。 + &dtrace; 工具包包括了很多由 &dtrace; 特殊语言写成的脚本。 在 &sun; 的文档中称这类语言为 D 语言, 它与 C++ 非常类似。对此语言更深入的讨论则超出了这篇文章的范围。 更多相关的讨论可以在 找到。 diff --git a/zh_CN.GB2312/books/handbook/eresources/chapter.sgml b/zh_CN.GB2312/books/handbook/eresources/chapter.sgml index ce6f1195dd..7f2601bb73 100644 --- a/zh_CN.GB2312/books/handbook/eresources/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/eresources/chapter.sgml @@ -1,1745 +1,1772 @@ Internet上的资源 发展迅猛的FreeBSD使得现有的印刷、平面媒体跟不上它的发展进度! 而电子版的也许是最好的,通常是唯一一个可以跟上最新发展方向的。FreeBSD来自于志愿者的成果, - 用户社区通常也扮演着是“技术支持部门”的角色。通过电子邮件和USENET新闻组可以很快的找到他们。 + 用户社区通常也扮演着是“技术支持部门”的角色。通过电子邮, Web 论坛件和 USENET + 新闻组可以很快的找到他们。 以下列出了尽量多的联系FreeBSD用户社区的方式。如果您发现有其他的资源没有被包括在这儿, 请告诉&a.doc;,以便将它们加入到这里。 邮件列表 - 虽然大部分的FreeBSD开发人员都会阅读USENET, - 如果您只将问题发表在 comp.unix.bsd.freebsd.* 其中之一的讨论组上, - 我们也不能保证我们永远可以及时了解您的问题。如果您将问题发到适当的邮件列表上, - 您不但可以同时让FreeBSD研发人员和其他的读者看到, - 通常也可以得到一个较好的(至少会比较快)的回应。 + 邮件列表通常是提问或是发起有关 FreeBSD + 某一方面的专项技术讨论最直接的途径。 有多种针对于不同 FreeBSD 话题的邮件列表。 + 把你的问题发送到最合适的邮件列表通常能获得更加快速准确的回复。 本文的最后给出了各个不同的邮件列表的使用规则。 在订阅其中任何一个列表之前,请先阅读使用条文。 现在订阅这些邮件列表的人每天都会收到上百封关于FreeBSD的信件。 设立列表的使用条文有助于维护讨论质量。否则这些讨论计划的列表将失去其意义。 如果你想要尝试发送一封邮件到 &os; 邮件列表,你可以把邮件发往 &a.test.name;。 请不要往其他的列表发送测试邮件。 如果不知道哪个邮件列表适合于发送您的问题, 请参见 如何从 FreeBSD-questions 邮件列表中更快地得到答案 在列表中发送任何问题之前, 请首先学习使用邮件列表的最佳方式, 例如如何通过阅读 邮件列表常见问题回答集 (FAQ) 文档, 来避免经常重复的讨论。 全部的邮件列表记录都可以在FreeBSD World Wide Web服务器上找到。此服务器提供了很棒的关键词搜寻功能,可让您找到FAQ的解答。 - 而在邮件列表上提问之前,请先搜寻是否已有答案。 + 而在邮件列表上提问之前,请先搜寻是否已有答案。 + 请注意这意味着所有发往 FreeBSD 邮件列表的消息都会被永久归档保存。 + 当涉及到隐私保护的话, + 可以考虑使用一个可使用后丢弃的电子邮件地址并只发送公开的信息。 列表摘要 一般性的列表: 以下的列表都是一般性的, 而且可以自由地加入,鼓励大家加入他们: 目录 用途 &a.advocacy.name; FreeBSD鼓吹者 &a.announce.name; 重要的事件和里程碑 &a.arch.name; 架构和设计的讨论 &a.bugbusters.name; 与FreeBSD问题报告数据库和有关工具维护相关的讨论 &a.bugs.name; 报告FreeBSD的Bug &a.chat.name; 和技术无关的FreeBSD讨论区 &a.current.name; 讨论使用 &os.current; 有关的一些问题 &a.isp.name; ISP使用FreeBSD的讨论 &a.jobs.name; 与FreeBSD有关的工作机会 &a.policy.name; FreeBSD核心团队方针讨论。低流量并且只读的 &a.questions.name; 用户问题和技术支持 &a.security-notifications.name; 安全通知 &a.stable.name; 讨论使用 &os.stable; 有关的一些问题 &a.test.name; 在真正发送一个邮件到邮件列表之前可以先发送到这里测试 技术性的邮件列表: 以下的邮件列表是用来讨论技术性问题的。 在加入订阅及讨论之前请务必认真阅读每个列表主题,因为他们讨论的内容都是严格地被限制着的。 目录 用途 &a.acpi.name; ACPI 和电源管理的开发 &a.afs.name; 将 AFS 移植到 FreeBSD &a.aic7xxx.name; 为 &adaptec; AIC 7xxx 开发驱动 &a.alpha.name; 将 FreeBSD 移植到 Alpha 工作站 &a.amd64.name; 将 FreeBSD 移植到 AMD64 系统 &a.apache.name; 关于与 Apache 有关的 ports 的讨论 &a.arm.name; 将 FreeBSD 移植到 &arm; 处理器 &a.atm.name; 在 FreeBSD 上使用 ATM 网络 &a.audit.name; 源代码审核 &a.binup.name; 二进制更新系统的设计和开发 &a.bluetooth.name; 在 FreeBSD 上使用 &bluetooth; 技术 &a.cluster.name; 在集群环境中使用 FreeBSD &a.cvsweb.name; CVSweb 维护 &a.database.name; 讨论 FreeBSD 下开发和使用数据库 &a.doc.name; 创建 FreeBSD 相关文档 &a.drivers.name; 为 &os; 撰写驱动 &a.eclipse.name; &os; 上的 Eclipse IDE、工具、 富客户应用, 以及 ports 的用户讨论。 &a.embedded.name; 在嵌入式应用中使用 FreeBSD &a.eol.name; 关于与 FreeBSD 有关, 但已不再为 FreeBSD Project 所维护的软件的互助支持。 &a.emulation.name; 在 FreeBSD 上模拟其它系统, 如 Linux/&ms-dos;/&windows; &a.firewire.name; FreeBSD 的 &firewire; (iLink, IEEE 1394) 技术讨论 &a.fs.name; 文件系统 &a.geom.name; 针对 GEOM 的讨论和实现 &a.gnome.name; 移植 GNOMEGNOME应用程序 &a.hackers.name; 一般性的技术讨论 &a.hardware.name; 一般性的支持 FreeBSD 的硬件的讨论 &a.i18n.name; FreeBSD 的国际化 &a.ia32.name; 在 IA-32 (&intel; x86) 平台上运行 FreeBSD &a.ia64.name; 将 FreeBSD 移植到 &intel; 即将推出的 IA64 系统 &a.ipfw.name; 关于 IP 防火墙代码再设计的技术性讨论 &a.isdn.name; ISDN开发人员 &a.jail.name; 关于 &man.jail.8; 机制的讨论 &a.java.name; &java; 开发人员以及移植 &jdk;s 到 FreeBSD 的人们 &a.kde.name; 移植 KDEKDE 应用程序 &a.lfs.name; 移植 LFS 到FreeBSD上 &a.libh.name; 第二代的安装和 package 系统 &a.mips.name; 移植 FreeBSD 到 &mips; &a.mobile.name; 关于便携式计算机的讨论 &a.mozilla.name; 移植 Mozilla 到 FreeBSD 上 &a.multimedia.name; 多媒体应用程序 &a.newbus.name; 技术讨论关于总线架构 &a.net.name; 网络子系统和 TCP/IP 源代码的讨论 &a.openoffice.name; 移植 OpenOffice.org&staroffice; 到 FreeBSD 上 &a.performance.name; 高性能、负载下安装后的性能调整问题 &a.perl.name; 许多与 perl 相关的 ports 的维护 &a.pf.name; 关于 packet filter 防火墙系统的讨论 &a.platforms.name; 关于向非 &intel; 架构的平台上移植的讨论 &a.ports.name; 关于 Ports Collection 的讨论 &a.ports-bugs.name; ports bugs/PRs讨论 &a.ppc.name; 移植 FreeBSD 到 &powerpc; &a.proliant.name; 关于 FreeBSD 在 HP ProLiant 服务器平台上的技术讨论 &a.python.name; FreeBSD 专属的 Python 问题 &a.qa.name; 质量保证(QA)讨论, 通常在未发布之前 &a.rc.name; 关于 rc.d 系统及其开发的讨论 &a.realtime.name; FreeBSD 实时扩展的开发 &a.ruby.name; 关于 FreeBSD 上 Ruby 的讨论 &a.scsi.name; SCSI 子系统 &a.security.name; 系统安全 &a.small.name; 在嵌入式系统上使用 FreeBSD (已过时; 请使用 &a.embedded.name; 代替) &a.smp.name; 有关对称多处理器的设计讨论 &a.sparc.name; 移植 FreeBSD 到 &sparc; 系统 &a.standards.name; 让 FreeBSD 顺应 C99 以及 &posix; 标准 &a.sun4v.name; 将 FreeBSD 移植到基于 &ultrasparc; T1 的系统上 &a.threads.name; 线程 &a.testing.name; FreeBSD 性能和稳定性测试 &a.tokenring.name; 在 FreeBSD 中支持 Token Ring &a.usb.name; 关于 &os; 的 USB 支持的讨论 &a.virtualization.name; 讨论各种 &os; 支持的虚拟化技术 &a.vuxml.name; 关于 VuXML 的问题讨论 &a.x11.name; 维护和支持在 FreeBSD 上运行的 X11 &a.xen.name; 讨论 &os; &xen; 上的移植 — 实现和使用 限制订阅的列表: 以下的列表是针对某些特定的读者而设的, 而且并不适合被当成是一般公开讨论区。您最好在某一技术讨论区参与讨论后再选择订阅这些 限制订阅的邮件列表,因为这样您可以了解到在这些讨论区发言所需要的礼仪。 目录 用途 &a.hubs.name; 运行镜象站点的成员(支持基本服务) &a.usergroups.name; 用户组调整 &a.vendors.name; 商家在发布之前的调整 &a.wip-status.name; FreeBSD 项目进度状态 &a.www.name; www.FreeBSD.org的维护 分类列表: 所有以上的列表在一个分类格式里面是可利用的。 一旦订阅了一个列表,您可以在您的账号选项里面设置您的分类选项。 CVS 和 SVN 列表: 以下的邮件是给对FreeBSD源代码的变更记录有兴趣的人看的, 而且它们是只读的邮件列表,您不能发Email给他们。 列表 源位置 描述 &a.cvsall.name; /usr/(CVSROOT|doc|ports) 所有对源代码的改变纪录 (其他 CVS commit 列表的超集) &a.cvs-doc.name; /usr/(doc|www) 所有对 doc 和 www 源代码的改变记录 &a.cvs-ports.name; /usr/ports 所有对 ports 源代码的改变记录 &a.cvs-projects.name; /usr/projects 所有对 projects 源代码的改变记录 &a.cvs-src.name; /usr/src 所有对 src 源代码的改变记录 (由 svn-to-cvs 提交导入程序生成) &a.svn-src-all.name; /usr/src 所有对 Subversion 仓库的改变记录 (除了 userprojects) &a.svn-src-head.name; /usr/src 所有对 Subversion 仓库 head 分支的改变记录 (&os;-CURRENT 分支) &a.svn-src-projects.name; /usr/projects 所有对 Subversion 源码仓库中有关 projects 部分的改变记录 &a.svn-src-release.name; /usr/src 所有对 Subversion 源码仓库中有关 releases 部分的改变记录 &a.svn-src-releng.name; /usr/src 所有对 Subversion 源码仓库中有关 releng 部分的改变记录 (security / release engineering 分支) &a.svn-src-stable.name; /usr/src 所有对 Subversion 源码仓库中有关 stable 分支的改变记录 &a.svn-src-stable-6.name; /usr/src 所有对 Subversion 源码仓库中有关 stable/6 分支的改变记录 &a.svn-src-stable-7.name; /usr/src 所有对 Subversion 源码仓库中有关 stable/7 分支的改变记录 &a.svn-src-stable-other.name; /usr/src 所有对 Subversion 源码仓库中早期 stable 分支的改变记录 &a.svn-src-svnadmin.name; /usr/src 所有对 Subversion 源码仓库中管理用脚本, hook 和其他配置数据的改变记录 &a.svn-src-user.name; /usr/src 所有对 Subversion 源码仓库中有关 user 部分的改变记录 &a.svn-src-vendor.name; /usr/src 所有对 Subversion 源码仓库中有关 vender 部分的改变记录 如何订阅 订阅一个列表,点击上面的列表名字或到 &a.mailman.lists.link; 并点击进入您感兴趣的列表,这个列表的页面包含了所必需的订阅操作指南。 其实您只需发送邮件到 列表名@FreeBSD.org。 它将被再次转发到全世界的这个邮件列表的成员。 点击上面的 URL,在列表的底部可以从订阅的列表中退出。 也可以发送一个电子邮件到 列表名-unsubscribe@FreeBSD.org 来退订。 此外,我们要求您必须保持在技术性的邮件列表中只是讨论技术。 如果您只是对一些重要的公告感兴趣,建议您加入 &a.announce;, 它的通信量比较低。 列表规章 所有 FreeBSD 的邮件列表都有同样的基本规则, 所有人必须按照规则来做。 违反这些规则时, FreeBSD Postmaster postmaster@FreeBSD.org 会在前两次发送警告, 如果第三次违反, FreeBSD Postmaster 将从所有 FreeBSD 的邮件列表中删除这样的人, 并过滤来自发信人之后的所有邮件。 我们很遗憾必须要遵守这样的规则, 但今天的互联网是一个很混乱的环境, 它上面的很多约束机制, 都相当脆弱。 具体规则: 任何发表的主题都应当附合基本的列表概况。例如,如果列表是有关技术问题的, 那您发表的文章包含技术讨论。不要把不相关的讨论放在一起。 对于没有主题的自由形式的讨论,可以使用 FreeBSD-chat freebsd-chat@FreeBSD.org 不要将同一个问题发送到超过两个的邮件列表上,当有一个清晰和明显的必须要 发表到两个列表的要求时,也只能是两个。对于大多数的列表,已经有相当多的订户了, 除了一些比较深奥的问题(如-stable & -scsi) ,没有必要同时将一个问题发到多个列表上。 如果一个信息以这种方式(多个邮件列表在Cc行出现)被发送给您, 那Cc行在把它再发送出去之前也将被整理。 无论谁是最初发表者,都会导致您自己的交叉发送。 不容许进行人身攻击和亵渎(在前后的争论中),包括用户和开发人员。 应当遵守最起码的网络礼节,象需要征得同意才可以引用或张贴私人邮件等。 然而,也有非常少的情况下,这样的内容会符合列表规章, 因此,它会在最初给予警告(或禁止)。 严格的禁止非FreeBSD相关产品或服务的广告,一旦发现将马上取缔。 单独的列表规章: &a.acpi.name; ACPI和电源管理开发 &a.afs.name; Andrew文件系统 这个列表是用来讨论porting和从CMU/Transarc使用AFS。 &a.announce.name; 重要事件/里程碑 这是一个发布FreeBSD重大事件的邮件列表。这包括有关snapshots和其他版本的公告, 新的FreeBSD的性能的公告,还可以用于指派志愿者等等。这个列表比较小。 &a.arch.name; 架构和设计讨论 这个列表是讨论FreeBSD的架构。本质上应保证内容的纯技术性。例如主题是: 如何重新创建系统使其同时有几个自己构造的系统运行。 需要什么才能修复VFS来使Heidemann层工作。 我们怎么改变设备驱动程序接口以便能够在多种总线和体系结构上使用同样的驱动程序。 如何写一个网络驱动。 &a.audit.name; 源代码审核计划 这个是针对FreeBSD源代码审核计划的邮件列表, 虽然这最初是针对安全方面代码修正的讨论,现在它已经扩展到任何代码修正的讨论。 这个列表涉及补丁方面的问题比较多,可能普通的FreeBSD用户对此不感兴趣。 不与一个特定的代码修正相关的安全讨论将放在freebsd-security中。相反的, 所有的开发人员都被鼓励把他们的补丁发到这儿来, 特别是如果他们发现有一个错误可能会影响系统的完整性时。 &a.binup.name; FreeBSD二进制升级计划 这个列表主要是讨论二进制升级binup系统。 设计问题,执行细节,补丁,错误报告,状态报告,特性要求, 提交日志,和所有其他与 binup相关的东西都可以。 &a.bluetooth.name; FreeBSD 上的 &bluetooth; 这是一个 FreeBSD 的 &bluetooth; 用户聚集的讨论区。 这里欢迎关于设计问题、 实现细节、 补丁、 问题报告、 开发进度报告, 功能需求以及其他与 &bluetooth; 相关的讨论。 &a.bugbusters.name; 同等问题报告处理结果 这个列表的目的是作为一个调整和讨论论坛来服务于Bug列表的成员,Bugbuster列表成员 和其他任何的对PR数据库真正的有兴趣的成员。这个列表不是为了讨论关于Bug细节,补丁或PRs。 &a.bugs.name; Bug报告 这是一个报告FreeBSD的Bug的邮件列表。可以随时通过 &man.send-pr.1; 命令或WEB页面来提交Bug。 &a.chat.name; 与FreeBSD社区相关的非技术性项目 这个列表超出了其他有关非技术、社会信息的内容。 包括谈论Jordan看起来是否像一个机敏的侦探,是否句首的字母要大写, 谁喝了很多咖啡, 哪儿的啤酒酿造的最好,谁在他们的地下室里酿造了啤酒等等。对于偶然宣布重大的事件 (例如:将要举行的聚会,婚礼,生日,新工作等等)也能使用这种技术列表,除上述列举之外 任何事情都可以发布在-chat列表上。 &a.core.name; FreeBSD核心团队 这是一个只供核心成员内部使用的邮件列表,只有当一个与FreeBSD相关的严重的事情需要裁决或严格审核时, 才能发送消息到这个邮件列表。 &a.current.name; 关于使用&os.current;版的讨论 这是一个针对&os.current;用户的邮件列表。 它包括一些可能影响用户的新特性的警告,使用FreeBSD-current的一些指导。 任何运行CURRENT的人必须同意这个列表,这是一个纯技术的邮件列表。 &a.cvsweb.name; FreeBSD CVSweb计划 关于FreeBSD-CVSweb的使用,开发和维护的技术性讨论。 &a.doc.name; 文档计划 这个邮件列表是与FreeBSD创建的文档的出版和计划的讨论。 这个邮件列表的成员都会提交到The FreeBSD Documentation Project。 它是一个开放的列表,可以自由地加入和做贡献! &a.drivers.name; 为 &os; 撰写设备驱动 这是关于 &os; 上的设备驱动的技术论坛。 它主要供编写设备驱动的开发人员提出关于如何使用 &os; 内核提供的 API 来编写设备驱动程序的问题。 &a.eclipse.name; &os; 上的 Eclipse IDE、工具、 富客户应用, 以及 ports 的用户讨论。 这个邮件列表的目的, 是为在 &os; 平台上选择、 安装、 使用、 开发和维护 Eclipse IDE、 工具、 富客户应用的用户, 提供互助式支持, 以及为将 Eclipse IDE 和插件移植到 &os; 环境中提供帮助。 另一个目的是建立一个在 Eclipse 社区和 &os; 社区之间的交流管道, 以达到互惠互利。 尽管这个列表主要关注的是 Eclipse 用户的诉求, 它也为使用 Eclipse 框架开发 &os; 专用的应用提供了论坛。 &a.embedded.name; 在嵌入式应用中使用 FreeBSD 这个列表讨论关于在嵌入式系统中如何使用 FreeBSD 的话题。 这是一个技术性的邮件列表, 其主要内容是技术讨论。 针对这一邮件列表, 我们将嵌入式系统定义为那些不作为桌面系统、 只完成某些单一任务的计算设备。 这些实例包括路由器交换机和 PBX 这样的网络设备、 远程测量设备、 PDA、 PoS 系统,等等。 &a.emulation.name; 模拟其他系统, 例如 Linux/&ms-dos;/&windows; 这是一个讨论关于如何在 &os; 上运行为其他操作系统所撰写的程序的论坛。 &a.eol.name; 关于与 FreeBSD 有关, 但已不再为 FreeBSD Project 所维护的软件的互助支持。 这个邮件列表主要用于那些有兴趣提供或使用针对已不再为 FreeBSD Project 官方所支持 (例如, 以安全更新或补丁的形式) 的 FreeBSD 相关软件的用户或公司讨论。 &a.firewire.name; &firewire; (iLink, IEEE 1394) 这个邮件列表是关于FreeBSD子系统&firewire; (aka IEEE 1394 aka iLink)的设计和执行。相关特定的主题包括标准,总线设计和他们的协议, 适配器板/卡/芯片设置,及他们的正确的代码的结构和实施。 &a.fs.name; 文件系统 关于FreeBSD文件系统的讨论。这是一个纯技术的邮件列表。 &a.geom.name; GEOM 针对GEOM和相关执行的讨论。这是一个纯技术的邮件列表。 &a.gnome.name; GNOME 讨论关于在FreeBSD系统上的GNOME桌面环境 这是一个纯技术的邮件列表。 &a.ipfw.name; IP防火墙 这是关于在FreeBSD里重新设计IP防火墙代码的技术讨论论坛。 &a.ia64.name; 移植FreeBSD到IA64 这是一个有关将FreeBSD移植到&intel; IA64架构上的技术讨论列表, 讨论一些相关的问题与解决方案。也欢迎对这些问题感兴趣的个别讨论者。 &a.isdn.name; ISDN通信 这是一个FreeBSD支持的ISDN系统开发的邮件列表。 &a.java.name; &java;开发 这是一个讨论&java; 应用开发和 &jdk;s的porting与维护的邮件列表。 &a.jobs.name; 工作的提供和寻找 这个论坛是针对与 &os; 相关的雇佣信息和个人简历, 比如: 如果您想找一个与 &os; 相关的工作或有一个工作需要 &os; 这是一个让您来广告的好地方。 这 是对一般性雇佣问题的邮件列表, 对这个问题已经有了足够多的论坛。 注意这个列表,像其他的 FreeBSD.org 邮件列表一样是会分发给全世界的订阅者的。 因此,您需要明白关于位置和地域问题,确定之间是容易联系和可合作的。 Email最好应该使用 —纯文本格式,不过基本的PDF,HTML和 很少其他的能被更多读者接受的格式也是可以的。µsoft; Word (.doc) 格式是被邮件列表服务器拒绝的。 &a.kde.name; KDE 讨论关于在FreeBSD系统上使用KDE。 这是一个纯技术的邮件列表。 &a.hackers.name; 技术讨论 这是一个与FreeBSD相关的技术讨论论坛,是一个主要的技术性邮件列表。 他是针对个别的工作在FreeBSD上的人来提出问题或讨论相关的解决方案, 也欢迎对这些问题感兴趣的个别的讨论者。这是一个纯技术的邮件列表。 &a.hardware.name; FreeBSD硬件的普通讨论 有关FreeBSD运行的硬件类型的普通讨论,包括是否该买的一些问题和建议。 &a.hubs.name; 镜象站点 人们运行FreeBSD的镜象站点的公告和讨论。 &a.isp.name; ISP供应商问题 这是一个讨论使用FreeBSD的ISP供应商的邮件列表。这是一个纯技术的邮件列表。 &a.openoffice.name; OpenOffice.org 关于OpenOffice.org&staroffice;. 的移植和维护。 &a.performance.name; 讨论关于调整及高速运行FreeBSD 这个邮件列表提供了一个为黑客,管理员和有关的团体去讨论与FreeBSD性能相关的主题的空间。 可以在这里进行讨论的包括在任意高负载下,体验版下或者是有限制的条件下安装FreeBSD。 非常鼓励自愿地为了改进FreeBSD性能的相关团体去订阅这个列表。 这是个高技术含量的列表理论上说适合有丰富经验的FreeBSD用户,黑客,或对FreeBSD的速度、性能 、升级感兴趣的管理员。这不是一个问答式的列表,关于这些应该去读相关文档,但他是 一个可以投稿的地方,或者了解关于待解决的与性能相关的主题。 &a.pf.name; 关于 packet filter 防火墙系统的问题和讨论 关于 FreeBSD 环境下 packet filter (pf) 防火墙系统的讨论。 这里欢迎技术讨论, 以及一般的应用问题。 此外, 这里也是讨论 ALTQ QoS 框架的合适场所。 &a.platforms.name; 移植到非 &intel; 平台上 跨平台的 FreeBSD 问题, 关于非 &intel; FreeBSD 移植版本的讨论和提议。 这是一个纯技术性的邮件列表, 其讨论内容严格限制为技术。 &a.policy.name; 核心团队策略的决定 这是一个很小的只读的有关核心团队策略决定的邮件列表。 &a.ports.name; ports的讨论 关于FreeBSD的ports collection (/usr/ports)的讨论, ports的基础构造和调整过的ports结构。这是一个纯技术的邮件列表。 &a.ports-bugs.name; ports bugs的讨论 讨论关于FreeBSD的ports collection (/usr/ports),问题报告 ports建议,或者ports的修正。这是一个纯技术的邮件列表。 &a.proliant.name; 关于 FreeBSD 在 HP ProLiant 服务器平台上的技术讨论 这个邮件列表用来讨论在 HP ProLiant 服务器上使用 FreeBSD, 包括讨论 ProLiant 专用的驱动、 管理软件、 配置工具, 以及 BIOS 更新等。 同样地, 这里也是讨论 hpasmd、 hpasmcli, 以及 hpacucli 模块的主要场所。 &a.python.name; FreeBSD 上的 Python 这是一个讨论关于如何在 FreeBSD 上改善 Python 支持的邮件列表。 这是一个纯技术的邮件列表。 它是为那些移植 Python、 其第三方模块, 以及 Zope 相关软件到 FreeBSD 上的人准备的。 这里也欢迎参与技术讨论的人。 &a.questions.name; 用户问题 这是一个有关FreeBSD问题的邮件列表。您不应当发送how to 问题给技术列表,除非您认为这个问题是非常可爱的技术问题。 &a.ruby.name; 有关 FreeBSD 上 Ruby 的讨论 这是一个讨论关于 Ruby 在 FreeBSD 上支持的邮件列表。 这是一个纯技术的邮件列表。它是为那些移植 Ruby、第三方库以及 各种 framework 准备的。 这里也欢迎参与技术讨论的人。 &a.scsi.name; SCSI子系统 这是一个讨论FreeBSD的SCSI子系统的邮件列表。这是一个纯技术的列表。 &a.security.name; 安全问题 FreeBSD的计算机安全问题(DES,Kerberos,已知的安全漏洞和修复等)。 这是一个纯技术的邮件列表。注意:这不是一个问和答的列表,但是同时给出 问题和答案到FAQ是欢迎的。 &a.security-notifications.name; 安全通知 FreeBSD安全问题和修复的通知。这不是一个讨论列表,讨论的列表应当是FreeBSD-security &a.small.name; 在嵌入式应用程序中使用FreeBSD 这个列表讨论了与极小的和嵌入的FreeBSD安装的讨论主题。 这是一个纯技术的列表。 这一列表已被 &a.embedded.name; 代替。 &a.stable.name; 讨论关于&os.stable;版的使用 这是一个&os.stable;用户的邮件列表。它包括-STABLE的新特性可能会影响用户的警告。 任何运行STABLE的人应当经常关注这个列表。这是一个纯技术的列表。 &a.standards.name; C99 & POSIX一致 这是关于FreeBSD顺应C99和POSIX标准的技术讨论论坛。 &a.usb.name; 讨论 &os; 的 USB 支持 这个邮件列表是关于 &os; 上的 USB 支持的技术性讨论。 &a.usergroups.name; 用户组调整列表 这个邮件列表为协调从各地的使用群体到彼此相互讨论问题和 从核心团队中指定个人。这个邮件列表应被限制到大纲和协调用户组 计划的范围之内。 &a.vendors.name; 商家 讨论FreeBSD计划和FreeBSD软硬件商家的协调。 &a.virtualization.name; 讨论各种 &os; 支持的虚拟化技术 讨论 &os; 所支持的各种虚拟化技术的邮件列表。 在注重实现基本功能,加入新特性的同时, 也为用户提供了一个寻求帮助和讨论他们的使用经验的场所。 &a.wip-status.name; &os; 项目进度状态 这个邮件列表是用来发布 &os; 相关项目的创建和工作进度的。 发至这个列表的消息将会先被审核。通常建议把消息用 "To:" 发给一个更典型的 &os; 列表,而只仅仅 "BCC:" 给这个列表。 这样你的工作进度就能在典型的列表上讨论, 因为这个列表是不允许讨论问题的。 查看一下归档中合适的消息作为例子。 可能每隔几个月, 会从这个列表中的消息中提取出一个评论性的消息摘要发到 &os; 网站做为状态报告的一部分 。 你也能从那里找到更多的例子和以往的报告。 &a.xen.name; 讨论 &os; 有关 &xen; 上的移植 — 实现和使用 这个邮件列表集中讨论 &os; 的 &xen; 移植。 预期的流量会很小,所以这个列表旨在同时为 设计与实现细节的技术讨论和管理部属问题 提供一个讨论的场所。 过滤邮件列表 &os;邮件列表是使用了多种过滤方法去消除垃圾邮件、病毒和其他没用的电子邮件。 这部分所描述的并不包括所有常用的保护邮件列表的消除方法。 邮件列表只包含一些允许的附件类型。所有在列表中有MIME类型的附件的电子邮件在 邮件列表中被转发之前将被过滤掉。 application/octet-stream application/pdf application/pgp-signature application/x-pkcs7-signature message/rfc822 multipart/alternative multipart/related multipart/signed text/html text/plain text/x-diff text/x-patch 一些邮件列表可以允许附件为其他MIME类型,但是以上列出的 应该被多数的邮件列表所采用。 如果一个电子邮件包含HTML和纯文本形式,HTML的形式将被删除。 如果一个电子邮件内容只是HTML形式,他将被转换为纯文本格式。 Usenet新闻组 除了FreeBSD两个特殊的新闻组,还有很多讨论FreeBSD或与FreeBSD用户相关的其他讨论组。 一些新闻组的关键词搜索档案是可以使用的, 有什么问题可以与Warren Toomey wkt@cs.adfa.edu.au联系。 BSD特殊的新闻组 comp.unix.bsd.freebsd.announce comp.unix.bsd.freebsd.misc de.comp.os.unix.bsd (德语) fr.comp.os.bsd (法语) it.comp.os.freebsd (意大利语) tw.bbs.comp.386bsd (繁体中文) Internet上其他的&unix;新闻组 comp.unix comp.unix.questions comp.unix.admin comp.unix.programmer comp.unix.shell comp.unix.user-friendly comp.security.unix comp.sources.unix comp.unix.advocacy comp.unix.misc comp.bugs.4bsd comp.bugs.4bsd.ucb-fixes comp.unix.bsd X Window系统 comp.windows.x.i386unix comp.windows.x comp.windows.x.apps comp.windows.x.announce comp.windows.x.intrinsics comp.windows.x.motif comp.windows.x.pex comp.emulators.ms-windows.wine World Wide Web服务器 - &chap.eresources.www.inc; + + 论坛, 部落格, 社会性网络 + + + The + FreeBSD Forums 提供了一个基于 web 的论坛用以讨论 + FreeBSD 相关问题与技术。 + + Planet FreeBSD + 提供了众多由 FreeBSD 开发者部落格摘要的集合。 + 很多的开发者都在上面发表有关他们工作简要的笔记, + 新的补丁和工作进度。 + + The BSDConferences + YouTube Channel 提供了一组世界各地 BSD + 峰会的高质量视频。 这个是一个不错的观看重要开发者展示最新 + FreeBSD 有关成果的方法。 + + + + + Official Mirrors + &chap.eresources.www.inc; + Email地址 下面的用户组提供了与FreeBSD相关的邮件地址。如果他被滥用的话, 这个列表的管理员有收回的权利。 工具 用户组 管理员 ukug.uk.FreeBSD.org Forwarding only ukfreebsd@uk.FreeBSD.org Lee Johnston lee@uk.FreeBSD.org diff --git a/zh_CN.GB2312/books/handbook/filesystems/chapter.sgml b/zh_CN.GB2312/books/handbook/filesystems/chapter.sgml index 6efe9249af..e5b31d2596 100644 --- a/zh_CN.GB2312/books/handbook/filesystems/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/filesystems/chapter.sgml @@ -1,572 +1,572 @@ Tom Rhodes Written by 文件系统 Support 概述 File Systems File Systems Support File Systems 文件系统对于任何操作系统来说都是一个不可缺的部分。 它们允许用户上载和存储文件,提供对数据的访问,当然, 是使硬盘能具有实际的用途。不同的操作系统通常都有一个共同的主要方面, 那就是它们原生的文件系统。在 &os; 上这个文件系统通常被称为快速文件系统或者 FFS, 这是基于原来的 Unix™ 文件系统,通常也被称为 UFS。 这是 &os; 用于在磁盘上访问数据的原生的文件系统。 &os; 也支持数量繁多的不同的文件系统, 用于提供本地从其他操作系统上访问数据的支持, 那些就是指存放在本地挂载的 USB 存储设备,闪存设备和硬盘上的数据。还支持一些非原生的文件系统。 这些文件系统是在其他的操作系统上开发的,像 &linux; 的扩展文件系统 (EXT),和 &sun; 的 Z 文件系统 (ZFS)。 &os; 上对于各种文件系统的支持分成不同的层次。 一些要求加载内核模块,另外的可能要求安装一系列的工具。 这一章节旨在帮助 &os; 用户在他们的系统上访问其他的文件系统, 由 &sun; 的 Z 文件系统开始。 在阅读了这一章节之后,你将了解: 原生与被支持的文件系统之间的区别。 &os; 支持哪些文件系统。 如何起用,配置,访问和使用非原生的文件系统。 在阅读这章以前,你应该: 了解 &unix; 和 &os; 基本知识 ()。 熟悉基本的内核配置/编译方法 ()。 熟悉在 &os; 上安装第三方软件 ()。 熟悉 &os; 上的磁盘,存储和设备名 ()。 ZFS 特性目前仍被认为是试验性的。 有些选项功能性缺失,另有一些可能还无法运行。最终, 这个特性会适合用于生产,届时这篇文档也会做些适当的修改。 Z 文件系统 Z 文件系统是由 &sun; 开发使用存储池方法的新技术。 这就是说只有在需要存储数据的时候空间才会被使用。 它也为保护数据最大完整性而设计的,支持数据快照, 多份拷贝和数据校验。增加了被称为 RAID-Z 的新的数据复制类型。RAID-Z 是种类似于 RAID5类型, 但被设计成防止写入漏洞。 调整 ZFS ZFS 子系统需利用到大量的系统资源, 所以可能需要一些调校来为日常应用提供最大化的效能。 作为 &os; 的一项试验性的特性,这可能在不久的将来有所变化; 无论如何,下面的这些步骤是我们推荐的: 内存 总共的系统内存至少应有 1GB,推荐 2GB 或者更多。 在此处所有的例子中,我们使用了 1GB 内存的系统并配合了一些恰当的调校。 有些人在少于 1GB 内存的环境有幸正常使用, 但是在这样有限的物理内存的条件下,当系统的负载很高时, &os; 极有可能因于内存耗尽而崩溃。 内核配置 我们建议把未使用的驱动和选项从内核配置文件中去除。 既然大部份的驱动都有以模块的形式存在,它们就可以很容易的通过 /boot/loader.conf 加载。 i386 构架的用户应在内核配置文件中加入以下的选项, 重新编译内核并重启机器: options KVA_PAGES=512 这个选项将扩展内核的地址空间, 因而允许 vm.kvm_size 能够超越 1 GB 的限制(PAE为 2 GB)。 为了找出这个选项最合适的值, 把以兆(MB)为单位所需的地址空间除以 4 得到。 在这个例子中,512 则为 2 GB。 Loader 可调参数 所有构架上 &os; 都应该加大 kmem 地址空间。在有 1GB 物理内存的测试系统上,在 /boot/loader.conf 中加入如下的参数并且重启后通过了测试。 - vm.kmem_slze="330M" + vm.kmem_size="330M" vm.kmem_size_max="330M" vfs.zfs.arc_max="40M" vfs.zfs.vdev.cache.size="5M" 更多 ZFS 相关推荐调校的细节请参阅 . 使用 <acronym>ZFS</acronym> &os; 有一种启动机制能在系统初始化时挂在 ZFS 存储池。 可以通过以下的命令设置: &prompt.root; echo 'zfs_enable="YES"' >> /etc/rc.conf &prompt.root; /etc/rc.d/zfs start 这份文档剩余的部分假定系统中有2块 SCSI 磁盘可用, 它们的设备名分别为 da0da1IDE 硬件的用户可以使用 ad 代替 SCSI 单个磁盘存储池 在单个磁盘上创建 ZFS, 使用 zpool 命令: &prompt.root; zpool create example /dev/da0 可以通过 df 的输出查看新的存储池: &prompt.root; df Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/ad0s1a 2026030 235230 1628718 13% / devfs 1 1 0 100% /dev /dev/ad0s1d 54098308 1032846 48737598 2% /usr example 17547136 0 17547136 0% /example 这份输出清楚的表明了 example 存储池不仅创建成功而且被 挂载 了。 我们能像访问普通的文件系统那样访问它, 就像以下例子中演示的那样,用户能够在上面创建文件并浏览: &prompt.root cd /example &prompt.root; ls &prompt.root; touch testfile &prompt.root; ls -al total 4 drwxr-xr-x 2 root wheel 3 Aug 29 23:15 . drwxr-xr-x 21 root wheel 512 Aug 29 23:12 .. -rw-r--r-- 1 root wheel 0 Aug 29 23:15 testfile 遗憾的是这个存储池并没有利用到 ZFS 的任何特性。 在这个存储池上创建一个文件系统,并启用压缩: &prompt.root; zfs create example/compressed &prompt.root; zfs set compression=gzip example/compressed 现在 example/compressed 是一个启用了压缩的 ZFS 文件系统了。 可以尝试复制一些大的文件到 /example/compressed 使用这个命令可以禁用压缩: &prompt.root; zfs set compression=off example/compressed 使用如下的命令卸载这个文件系统,并用 df 工具确认: &prompt.root; zfs umount example/compressed &prompt.root; df Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/ad0s1a 2026030 235232 1628716 13% / devfs 1 1 0 100% /dev /dev/ad0s1d 54098308 1032864 48737580 2% /usr example 17547008 0 17547008 0% /example 重新挂在这个文件系统使之能被访问, 并用 df 确认: &prompt.root; zfs mount example/compressed &prompt.root; df Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/ad0s1a 2026030 235234 1628714 13% / devfs 1 1 0 100% /dev /dev/ad0s1d 54098308 1032864 48737580 2% /usr example 17547008 0 17547008 0% /example example/compressed 17547008 0 17547008 0% /example/compressed 存储池与文件系统也可通过 mount 的输出查看: &prompt.root; mount /dev/ad0s1a on / (ufs, local) devfs on /dev (devfs, local) /dev/ad0s1d on /usr (ufs, local, soft-updates) example on /example (zfs, local) example/data on /example/data (zfs, local) example/compressed on /example/compressed (zfs, local) 正如前面所提到的,ZFS 文件系统, 在创建之后就能像普通的文件系统那样使用。然而, 还有很多其他的特性是可用的。在下面的例子中, 我们将创建一个新的文件系统,data。 并要在上面存储些重要的文件, 所以文件系统需要被设置成把每一个数据块都保存两份拷贝: &prompt.root; zfs create example/data &prompt.root; zfs set copies=2 example/data 现在可以再次使用 df 查看数据和空间的使用状况: &prompt.root; df Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/ad0s1a 2026030 235234 1628714 13% / devfs 1 1 0 100% /dev /dev/ad0s1d 54098308 1032864 48737580 2% /usr example 17547008 0 17547008 0% /example example/compressed 17547008 0 17547008 0% /example/compressed example/data 17547008 0 17547008 0% /example/data 请注意存储池上的每一个文件系统都有着相同数量的可用空间。 这就是我们在这些例子中使用 df 的原因, 是为了文件系统都是从相同的存储池取得它们所需的空间。 ZFS 去掉了诸如卷和分区此类的概念, 并允许多个文件系统占用同一个存储池。 不再需要文件系统与存储池的时候能像这样销毁它们: &prompt.root; zfs destroy example/compressed &prompt.root; zfs destroy example/data &prompt.root; zpool destroy example 磁盘无法避免的会坏掉和停止运转。 当这块磁盘坏掉的时候,上面的数据都将丢失。 一个避免因磁盘损坏而丢失数据的方法是使用 RAIDZFS 在它的存储池设计中支持这样的特性, 这便是下一节将探讨的。 <acronym>ZFS</acronym> RAID-Z 正如前文中所提到的,这一章节将假设存在两个 SCSI 设备, da0da1。 使用如下的命令创建一个 RAID-Z 存储池: &prompt.root; zpool create storage raidz da0 da1 zpool storage 至此就创建好了。 可以如前文提到的那样使用 &man.mount.8; 和 &man.df.1; 确认。 如需配给更多的磁盘设备则把它们加这个列表的后面。 在存储池上创建一个叫 home 的文件系统, 用户的文件最终都将被保存在上面: &prompt.root; zfs create storage/home 像前文中提到的那样,用户的目录与文件也可启用压缩并保存多份拷贝, 可通过如下的命令完成: &prompt.root; zfs set copies=2 storage/home &prompt.root; zfs set compression=gzip storage/home 把用户的数据都拷贝过来并创建一个符号链接, 让他们开始使用这个新的目录: &prompt.root; cp -rp /home/* /storage/home &prompt.root; rm -rf /home /usr/home &prompt.root; ln -s /storage/home /home &prompt.root; ln -s /storage/home /usr/home 现在用户的数据应该都保存在新创建的 /storage/home 上了。 测试添加一个新用户并以这个身份登录。 尝试创建一个可日后用来回退的快照: &prompt.root; zfs snapshot storage/home@08-30-08 请注意快照选项将只会抓取一个真实的文件系统, 而不是某个用户目录或文件。@ 字符为文件系统名或卷名的分隔符。 当用户目录被损坏时,可用如下命令恢复: &prompt.root; zfs rollback storage/home@08-30-08 获得所有可用快照的列表,可使用 ls 命令查看文件系统的 .zfs/snapshot 目录。例如,执行如下命令来查看之前抓取的快照: &prompt.root; ls /storage/home/.zfs/snapshot 可以编写一个脚本来每月定期抓取用户数据的快照,久而久之, 快照可能消耗掉大量的磁盘空间。 之前创建的快照可用以下命令删除: &prompt.root; zfs destroy storage/home@08-30-08 在所有这些测试之后,我们没有理由再把 /store/home 这样放置了。让它称为真正的 /home 文件系统: &prompt.root; zfs set mountpoint=/home storage/home 使用 dfmount 命令将显示现在系统把我们的文件系统真正当作了 /home &prompt.root; mount /dev/ad0s1a on / (ufs, local) devfs on /dev (devfs, local) /dev/ad0s1d on /usr (ufs, local, soft-updates) storage on /storage (zfs, local) storage/home on /home (zfs, local) &prompt.root; df Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/ad0s1a 2026030 235240 1628708 13% / devfs 1 1 0 100% /dev /dev/ad0s1d 54098308 1032826 48737618 2% /usr storage 17547008 0 17547008 0% /storage storage/home 17547008 0 17547008 0% /home 这样就基本完成了 RAID-Z 的配置了。使用夜间 &man.periodic.8; 获取有关文件系统创建之类的状态更新, 执行如下的命令: &prompt.root; echo 'daily_status_zfs_enable="YES"' >> /etc/periodic.conf 修复 <acronym>RAID</acronym>-Z 每一种软 RAID 都有监测它们 状态 的方法。 ZFS 也不例外。 可以使用如下的命令查看 RAID-Z 设备: &prompt.root; zpool status -x 如果所有的存储池处于健康状态并且一切正常的话, 将返回如下信息: all pools are healthy 如果存在问题,可能是一个磁盘设备下线了, 那么返回的存储池的状态将看上去是类似这个样子的: pool: storage state: DEGRADED status: One or more devices has been taken offline by the administrator. Sufficient replicas exist for the pool to continue functioning in a degraded state. action: Online the device using 'zpool online' or replace the device with 'zpool replace'. scrub: none requested config: NAME STATE READ WRITE CKSUM storage DEGRADED 0 0 0 raidz1 DEGRADED 0 0 0 da0 ONLINE 0 0 0 da1 OFFLINE 0 0 0 errors: No known data errors 在这个例子中,这是由管理员把此设备下线后的状态。 可以使用如下的命令将磁盘下线: &prompt.root; zpool offline storage da1 现在切断系统电源之后就可以替换下 da1 了。 当系统再次上线时,使用如下的命令替换磁盘: &prompt.root; zpool replace storage da1 至此可用不带 标志的命令再次检查状态: &prompt.root; zpool status storage pool: storage state: ONLINE scrub: resilver completed with 0 errors on Sat Aug 30 19:44:11 2008 config: NAME STATE READ WRITE CKSUM storage ONLINE 0 0 0 raidz1 ONLINE 0 0 0 da0 ONLINE 0 0 0 da1 ONLINE 0 0 0 errors: No known data errors 在这个例子中,一切都显示正常。 数据校验 正如前面所提到的,ZFS 使用 校验和(checksum) 来检查存储数据的完整性。 这时在文件系统创建时自动启用的,可使用以下的命令禁用: &prompt.root; zfs set checksum=off storage/home 这不是个明智的选择,因为校验和 不仅非常有用而且只需占用少量的存储空间。 并且启用它们也不会明显的消耗过多资源。 启用后就可以让 ZFS 使用校验和校验来检查数据的完整。 这个过程通常称为 scrubbing。 可以使用以下的命令检查 storage 存储池里数据的完整性: &prompt.root; zpool scrub storage 这个过程需花费相当长的时间,取决于存储的数据量。 而且 I/O 非常密集, 所以在任何时间只能执行一个这样的操作。 在 scrub 完成之后,状态就会被更新, 可使用如下的命令查看: &prompt.root; zpool status storage pool: storage state: ONLINE scrub: scrub completed with 0 errors on Sat Aug 30 19:57:37 2008 config: NAME STATE READ WRITE CKSUM storage ONLINE 0 0 0 raidz1 ONLINE 0 0 0 da0 ONLINE 0 0 0 da1 ONLINE 0 0 0 errors: No known data errors 这个例子中完成时间非常的清楚。 这个特性可以帮助你在很长的一段时间内确保数据的完整。 Z 文件系统有更多的选项,请参阅 &man.zfs.8; 和 &man.zpool.8; 手册页。 diff --git a/zh_CN.GB2312/books/handbook/firewalls/chapter.sgml b/zh_CN.GB2312/books/handbook/firewalls/chapter.sgml index f10bbdb67d..26656b85ce 100644 --- a/zh_CN.GB2312/books/handbook/firewalls/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/firewalls/chapter.sgml @@ -1,3078 +1,3067 @@ Joseph J. Barbish Contributed by Brad Davis Converted to SGML and updated by 防火墙 防火墙 安全 防火墙 入门 防火墙的存在, 使得过滤出入系统的数据流成为可能。 防火墙可以使用一组或多组 规则 (rules), 来检查出入您的网络连接的数据包, 并决定允许或阻止它们通过。 这些规则通常可以检查数据包的某个或某些特征, 这些特征包括, 但不必限于协议类型、 来源或目的主机地址, 以及来源或目的端口。 防火墙可以大幅度地改善主机或网络的安全。 它可以用来完成下面的任务: 保护和隔离应用程序、 服务程序, 以及您内部网络上的机器, 不受那些来自公共的 Internet 网络上您所不希望的数据流量的干扰。 限制或禁止从内部网访问公共的 Internet 上的服务。 支持网络地址转换 (NAT), 它使得您的内部网络能够使用私有的 IP 地址, 并分享一条通往公共的 Internet 的连接 (使用一个 IP 地址, 或者一组公网地址)。 读完这章, 您将了解: 如何正确地定义包过滤规则。 &os; 中内建的集中防火墙之间的差异。 如何使用和配置 OpenBSD 的 PF 防火墙。 如何使用和配置 IPFILTER 如何使用和配置 IPFW 阅读这章之前, 您需要: 理解基本的 &os; 和 Internet 概念。 防火墙的概念 防火墙/primary> 规则集 建立防火墙规则集的基本方法有两种: 包容式的排斥式的。 排斥式的防火墙, 允许除了禁止的那些数据之外的所有网络流量通过。 包容式的防火墙正好相反。 后者只允许符合规则的流量通过, 而其他所有的流量都被阻止。 包容式防火墙一般说来要比排斥式防火墙安全, 因为他们显著地降低了由于允许不希望的网络流量通过所带来的风险。 如果使用了 带状态功能的防火墙 (stateful firewall), 则安全机制可以进一步地细化。 带状态功能的防火墙能够记录通过防火墙的连接, 进而只允许与现有连接匹配的连接, 或创建新的连接。 带状态功能的防火墙的缺点, 则是在很短时间内有大量的连接请求时, 它们可能会受到拒绝服务 (DoS) 攻击。 绝大多数防火墙都提供了同时启用两种防火墙的能力, 以便为站点提供更好的保护。 防火墙软件包 &os; 的基本系统内建了三种不同的防火墙软件包。 它们是 IPFILTER (也被称作 IPF)、 IPFIREWALL (也被称作 IPFW), 以及 OpenBSD 的 PacketFilter (也被称为 PF)。 &os; 也提供了两个内建的、 用于流量整形 (基本上是控制带宽占用) 的软件包: &man.altq.4; 和 &man.dummynet.4;。 Dummynet 在过去一直和 IPFW 紧密集成, 而 ALTQ 则需要配合 PF 使用。 IPFILTER 对于流量整形可以使用 IPFILTER 的 NAT 和过滤功能以及 IPFW 的 &man.dummynet.4; 配合, 或者 使用 PFALTQ 的组合。 IPFW, 以及 PF 都是用规则来控制是否允许数据包出入您的系统, 虽然它们采取了不同的实现方法和规则语法。 &os; 包含多个内建的防火墙软件包的原因在于, 不同的人会有不同的需求和偏好。 任何一个防火墙软件包都很难说是最好的。 作者倾向于使用 IPFILTER, 因为它提供的状态式规则, 在 NAT 的环境中要简单许多, 而且它内建了 ftp 代理, 这简化了使用外部 FTP 服务时所需的配置。 由于所有的防火墙都基于检查所选定的包控制字段来实现功能, 撰写防火墙规则集时, 就必须了解 TCP/IP 是如何工作的, 以及包的控制字段在正常会话交互中的作用。 您可以在这个网站找到一份很好的解释文档: . John Ferrell Revised and updated by OpenBSD Packet Filter (PF) 和 <acronym>ALTQ</acronym> 防火墙 PF 2003 年 7 月, OpenBSD 的防火墙, 也就是常说的 PF 被成功地移植到了 &os; 上, 并可以通过 &os; Ports Collection 来安装了; 第一个将 PF 集成到基本系统中的版本是 2004 年 11 月发行的 &os; 5.3。 PF 是一个完整的提供了大量功能的防火墙软件, 并提供了可选的 ALTQ (交错队列, Alternate Queuing) 功能。 ALTQ 提供了服务品质 (QoS) 带宽整形功能。 OpenBSD 项目非常杰出的维护着一份 PF FAQ。 就其本身而言,这一节注重于 &os; 的 PF 和提供一些关于使用方面的一般常识。更详细的使用信息请参阅 PF FAQ 更多的详细信息, 可以在 &os; 版本的 PF 网站上找到: 使用 PF 可装载的内核模块 从 &os; 5.3;开始,PF 作为一个单独的运行时可装载的模块被收录进基本的安装系统。 在 &man.rc.conf.5; 加入如下的语句能让系统能够动态装载 PF 内核模块,pf_enable="YES"。 然而如果系统无法找到一份 PF 防火墙规则的配置文件,PF 模块则不会被加载。 配置文件默认的位置在 /etc/pf.conf。 如果你的 PF 规则存放在其他的位置, 那么就需要在 /etc/rc.conf 配置文件中加入以下语句 pf_rules="/path/pf.rules" 来指定一份。 从 &os; 7.0 开始,作为例子的存放在 /etc/pf.conf 被移动到了/usr/share/examples/pf/。 &os; 7.0 以前的版本,默认仍有一份 /etc/pf.conf PF 模块也能从命令行手工加载: &prompt.root; kldload pf.ko 可装载的摸块默认由 &man.pflog.4; 提供日志记录。 如果你需要 PF 其他的特性, 你可能需要把 PF 编译进内核。 PF 内核选项 内核选项 device pf 内核选项 device pflog 内核选项 device pfsync 虽然你不必亲自把对 PF 的支持编译进 &os; 内核,但是有时你仍然需要这么做来使用到 PF 的某些没有被收录进可装载模块的高级特性,比如 &man.pfsync.4; 伪设备用来发送某些改变到PF 状态表。 它能配合 &man.carp.4; 使用 PF 建立支持故障转移的防火墙。 更多有关 CARP 的详细信息可以参阅 第 29 章。 The PF kernel options can be found in /usr/src/sys/conf/NOTES and are reproduced below: 有关 PF 的内核选项可以在 /usr/src/sys/conf/NOTES 中找到, 以下也略有阐述: device pf device pflog device pfsync device pf 选项用于启用 Packet Filter 防火墙的支持 (&man.pf.4;)。 device pflog 启用可选的 &man.pflog.4; 伪网络设备, 用以通过 &man.bpf.4; 描述符来记录流量。 &man.pflogd.8; 服务可以用来存储信息, 并把它们以日志形式记录到磁盘上。 device pfsync 选项启用可选的 &man.pfsync.4; 支持,这是用于监视 状态变更 的伪网络设备。 可用的 rc.conf 选项 The following &man.rc.conf.5; statements configure PF and &man.pflog.4; at boot: 以下 &man.rc.conf.5; 中的语句用于启动时配置 PF 和 &man.pflog.4; pf_enable="YES" # 启用 PF (如果需要的话, 自动加载内核模块) pf_rules="/etc/pf.conf" # pf 使用的规则定义文件 pf_flags="" # 启动时传递给 pfctl 的其他选项 pflog_enable="YES" # 启动 pflogd(8) pflog_logfile="/var/log/pflog" # pflogd 用于记录日志的文件名 pflog_flags="" # 启动时传递给 pflogd 的其他选项 如果您的防火墙后面有一个 LAN, 而且需要通过它来转发 LAN 上的包, 或进行 NAT, 还需要同时启用下述选项: gateway_enable="YES" # 启用为 LAN 网关 建立过滤规则 PF 会从 &man.pf.conf.5; (默认为 /etc/pf.conf) 文件中读取配置规则, 并根据那里的规则修改、丢弃或让数据包通过。 默认安装的 &os; 已经提供了一些简单的例子放在 /usr/share/examples/pf/ 目录下。 请参阅 PF FAQ 获取完整的 PF 规则信息。 在浏览 PF FAQ 时, 请时刻注意不同版本的 &os; 使用了不同版本的 PF: &os; 5.XPF 相当于 OpenBSD 3.5 &os; 6.XPF 相当于 OpenBSD 3.7 &os; 7.XPF 相当于 OpenBSD 4.1 &a.pf; 是一个提有关配置使用 PF 防火墙问题的好地方。请在提问之前查阅邮件列表的归档! 使用 PF 使用 &man.pfctl.8; 可以控制 PF。 以下是一些实用的命令 (请查阅 &man.pfctl.8; 获得全部可用的选项): 命令 作用 pfctl 启用 PF pfctl 禁用 PF pfctl all /etc/pf.conf 清楚所有规则 (nat, filter, state, table, 等等。) 并读取 /etc/pf.conf pfctl [ rules | nat | state ] 列出 filter 规则, nat 规则, 或状态表 pfctl /etc/pf.conf 检查 /etc/pf.conf 中的错误,但不装载相关的规则 启用 <acronym>ALTQ</acronym> ALTQ 只有在作为编译选项加入到 &os; 内核时才能使用。ALTQ 目前还不是所有的可用网卡驱动都能够支持的。 请参见 &man.altq.4; 联机手册了解您正使用的 &os; 版本中的驱动支持情况。 下面这些选项将启用 ALTQ 以及一些附加的功能: options ALTQ options ALTQ_CBQ # 基于分类的排列 (CBQ) options ALTQ_RED # 随机先期检测 (RED) options ALTQ_RIO # 对进入和发出的包进行 RED options ALTQ_HFSC # 带等级的包调度器 (HFSC) options ALTQ_PRIQ # 按优先级的排列 (PRIQ) options ALTQ_NOPCC # 在联编 SMP 内核时必须使用,禁止读时钟 options ALTQ 将启用 ALTQ 框架的支持。 options ALTQ_CBQ 用于启用基于分类的队列 (CBQ) 支持。 CBQ 允许您将连接分成不同的类别, 或者说, 队列, 以便在规则中为它们指定不同的优先级。 options ALTQ_RED 将启用随机预检测 (RED)。 RED 是一种用于防止网络拥塞的技术。 RED 度量队列的长度, 并将其与队列的最大和最小长度阈值进行比较。 如果队列过长, 则新的包将被丢弃。 如名所示, RED 从不同的连接中随机地丢弃数据包。 options ALTQ_RIO 将启用出入的随机预检测。 options ALTQ_HFSC 启用层次式公平服务平滑包调度器。 要了解关于 HFSC 进一步的信息, 请参见 options ALTQ_PRIQ 启用优先队列 (PRIQ)。 PRIQ 首先允许高优先级队列中的包通过。 options ALTQ_NOPCC 启用 ALTQSMP 支持。 如果是 SMP 系统, 则必须使用它。 IPFILTER (IPF) 防火墙 防火墙 IPFILTER 这一节的内容正在撰写中。 其内容可能不总是十分准确。 IPFILTER 的作者是 Darren Reed。 IPFILTER 是独立于操作系统的: 它是一个开放源代码的应用, 并且已经被移植到了 &os;、 NetBSD、 OpenBSD、 SunOS、 HP/UX, 以及 Solaris 操作系统上。 IPFILTER 的支持和维护都相当活跃, 并且有规律地发布更新版本。 IPFILTER 提供了内核模式的防火墙和 NAT 机制, 这些机制可以通过用户模式运行的接口程序进行监视和控制。 防火墙规则可以使用 &man.ipf.8; 工具来动态地设置和删除。 NAT 规则可以通过 &man.ipnat.1; 工具来维护。 &man.ipfstat.8; 工具则可以用来显示 IPFILTER 内核部分的统计数据。 最后, 使用 &man.ipmon.8; 程序可以把 IPFILTER 的动作记录到系统日志文件中。 IPF 最初是使用一组 以最后匹配的规则为准 的策略来实现的, 这种方式只能支持无状态的规则。 随着时代的进步, IPF 被逐渐增强, 并加入了 quick 选项, 以及支持状态的 keep state 选项, 这使得规则处理逻辑变得更富有现代气息。 IPF 的官方文档介绍了传统的规则编写方法和文件处理逻辑。 新增的功能只是作为一些附加的选项出现, 如果能完全理解这些功能, 则对于建立更安全的防火墙就很有好处。 这一节中主要是针对 quick 选项, 以及支持状态的 keep state 选项的介绍。 这是包容式防火墙规则集最基本的编写要素。 包容式防火墙只允许与规则匹配的包通过。 这样, 您就既能够控制来自防火墙后面的机器请求 Internet 公网上的那些服务, 同时也可以控制来自 Internet 的请求能够访问内部网上的哪些服务。 所有其它的访问请求都会被阻止, 并记录下来。 包容式防火墙一般而言要远比排斥式的要安全, 而且也只需要定义允许哪些访问通过。 要获得关于传统规则处理方式的详细信息, 请参考: 以及 IPF FAQ 可以在 找到。 除此之外, 您还可以在 找到开放源代码的 IPFilter 的邮件列表存档, 并进行搜索。 启用 IPF IPFILTER 启用 IPF 作为 &os; 基本安装的一部分, 以一个独立的内核模块的形式提供。 如果在 rc.conf 中配置了 ipfilter_enable="YES", 系统就会自动地动态加载 IPF 内核模块。 这个内核模块在创建时启用了日志支持, 并加入了 default pass all 选项。 如果只是需要把默认的规则设置为 block all 的话, 并不需要把 IPF 编译到内核中。 可以简单地通过把这条规则加入自己的规则集来达到同样的目的。 内核选项 内核选项 IPFILTER 内核选项 IPFILTER_LOG 内核选项 IPFILTER_DEFAULT_BLOCK IPFILTER 内核选项 下面这些 &os; 内核编译选项并不是启用 IPF 所必需的。 这里只是作为背景知识来加以阐述。 如果将 IPF 编入了内核, 则对应的内核模块将不被使用。 关于 IPF 选项语句的内核编译配置的例子, 可以在内核源代码中的 /usr/src/sys/conf/NOTES 找到。 此处列举如下: options IPFILTER options IPFILTER_LOG options IPFILTER_DEFAULT_BLOCK options IPFILTER 用于启用 IPFILTER 防火墙的支持。 options IPFILTER_LOG 用于启用 IPF 的日志支持, 所有匹配了包含 log 的规则的包, 都会被记录到 ipl 这个包记录伪—设备中。 options IPFILTER_DEFAULT_BLOCK 将改变防火墙的默认动作, 进而, 所有不匹配防火墙的 pass 规则的包都会被阻止。 这些选项只有在您重新编译并安装内核之后才会生效。 可用的 rc.conf 选项 要在启动时激活 IPF, 您需要在 /etc/rc.conf 中增加下面的设置: ipfilter_enable="YES" # 启动 ipf 防火墙 ipfilter_rules="/etc/ipf.rules" # 将被加载的规则定义, 这是一个文本文件 ipmon_enable="YES" # 启动 IP 监视日志 ipmon_flags="-Ds" # D = 作为服务程序启动 # s = 使用 syslog 记录 # v = 记录 tcp 窗口大小、 ack 和顺序号(seq) # n = 将 IP 和端口映射为名字 如果您的 LAN 在防火墙后面, 并且使用了保留的私有 IP 地址范围, 那就需要增加下面的一些选项来启用 NAT 功能: gateway_enable="YES" # 启用作为 LAN 网关的功能 ipnat_enable="YES" # 启动 ipnat 功能 ipnat_rules="/etc/ipnat.rules" # 用于 ipnat 的规则定义文件 IPF ipf ipf 命令可以用来加载您自己的规则文件。 一般情况下, 您可以建立一个包括您自定义的规则的文件, 并使用这个命令来替换掉正在运行的防火墙中的内部规则: &prompt.root; ipf -Fa -f /etc/ipf.rules 表示清除所有的内部规则表。 用于指定将要被读取的规则定义文件。 这个功能使得您能够修改自定义的规则文件, 通过运行上面的 IPF 命令, 可以将正在运行的防火墙刷新为使用全新的规则集, 而不需要重新启动系统。 这对于测试新的规则来说就很方便, 因为您可以任意执行上面的命令。 请参考 &man.ipf.8; 联机手册以了解这个命令提供的其它选项。 &man.ipf.8; 命令假定规则文件是一个标准的文本文件。 它不能处理使用符号代换的脚本。 也确实有办法利用脚本的非常强大的符号替换能力来构建 IPF 规则。 要了解进一步的细节, 请参考 IPFSTAT ipfstat IPFILTER 统计 默认情况下, &man.ipfstat.8; 会获取并显示所有的累积统计, 这些统计是防火墙启动以来用户定义的规则匹配的出入流量, 您可以通过使用 ipf -Z 命令来将这些计数器清零。 请参见 &man.ipfstat.8; 联机手册以了解进一步的细节。 默认的 &man.ipfstat.8; 命令输出类似于下面的样子: input packets: blocked 99286 passed 1255609 nomatch 14686 counted 0 output packets: blocked 4200 passed 1284345 nomatch 14687 counted 0 input packets logged: blocked 99286 passed 0 output packets logged: blocked 0 passed 0 packets logged: input 0 output 0 log failures: input 3898 output 0 fragment state(in): kept 0 lost 0 fragment state(out): kept 0 lost 0 packet state(in): kept 169364 lost 0 packet state(out): kept 431395 lost 0 ICMP replies: 0 TCP RSTs sent: 0 Result cache hits(in): 1215208 (out): 1098963 IN Pullups succeeded: 2 failed: 0 OUT Pullups succeeded: 0 failed: 0 Fastroute successes: 0 failures: 0 TCP cksum fails(in): 0 (out): 0 Packet log flags set: (0) 如果使用了 (进入流量) 或者 (输出流量), 它就只获取并显示内核中所安装的对应过滤器规则的统计数据。 ipfstat -in 以规则号的形式显示进入的内部规则表。 ipfstat -on 以规则号的形式显示流出的内部规则表。 输出和下面的类似: @1 pass out on xl0 from any to any @2 block out on dc0 from any to any @3 pass out quick on dc0 proto tcp/udp from any to any keep state ipfstat -ih 显示内部规则表中的进入流量, 每一个匹配规则前面会同时显示匹配的次数。 ipfstat -oh 显示内部规则表中的流出流量, 每一个匹配规则前面会同时显示匹配的次数。 输出和下面的类似: 2451423 pass out on xl0 from any to any 354727 block out on dc0 from any to any 430918 pass out quick on dc0 proto tcp/udp from any to any keep state ipfstat 命令的一个重要的功能可以通过指定 参数来使用, 它会以类似 &man.top.1; 的显示 &os; 正运行的进程表的方式来显示统计数据。 当您的防火墙正在受到攻击的时候, 这个功能让您得以识别、 试验, 并查看攻击的数据包。 这个选项提还提供了实时选择希望监视的目的或源 IP、 端口或协议的能力。 请参见 &man.ipfstat.8; 联机手册以了解详细信息。 IPMON ipmon IPFILTER 记录日志 为了使 ipmon 能够正确工作, 必须打开 IPFILTER_LOG 这个内核选项。 这个命令提供了两种不同的使用模式。 内建模式是默认的模式, 如果您不指定 参数, 就会采用这种模式。 服务模式是持续地通过系统日志来记录的工作模式, 这样, 您就可以通过查看日志来了解过去曾经发生过的事情。 这种模式是 &os; 和 IPFILTER 配合工作的模式。 由于在 &os; 中提供了一个内建的系统日志自动轮转功能, 因此, 使用 syslogd 比默认的将日志信息记录到一个普通文件要好。 在默认的 rc.conf 文件中, 您会看到一个 ipmon_flags 语句, 指定了 标志: ipmon_flags="-Ds" # D = 作为服务程序启动 # s = 使用 syslog 记录 # v = 记录 tcp 窗口大小、 ack 和顺序号(seq) # n = 将 IP 和端口映射为名字 记录日志的好处是很明显的。 它提供了在事后重新审查相关信息, 例如哪些包被丢弃, 以及这些包的来源地址等等。 这将为查找攻击者提供非常有用的第一手资料。 即使启用了日志机制, IPF 仍然不会对其规则进行任何日志记录工作。 防火墙管理员可以决定规则集中的哪些应记录日志, 并在这些规则上加入 log 关键字。 一般来说, 只应记录拒绝性的规则。 作为惯例, 通常会有一条默认的、拒绝所有网络流量的规则, 并指定 log 关键字, 作为您的规则集的最后一条。 这样, 您就能够看到所有没有匹配任何规则的数据包。 IPMON 的日志 Syslogd 使用特殊的方法对日志数据进行分类。 它使用称为 facilitylevel 的组。 以 模式运行的 IPMON 采用 security 作为 facility 名。 所有由 IPMON 记录的数据都会进入 security。 如果需要, 可以用下列 levels 来进一步区分数据: LOG_INFO - 使用 "log" 关键字指定的通过或阻止动作 LOG_NOTICE - 同时记录通过的那些数据包 LOG_WARNING - 同时记录阻止的数据包 LOG_ERR - 进一步记录含不完整的包头的数据包 要设置 IPFILTER 来将所有的数据记录到 /var/log/ipfilter.log, 需要首先建立这个文件。 下面的命令可以完成这个工作: &prompt.root; touch /var/log/ipfilter.log syslog 功能可以通过在 /etc/syslog.conf 文件中的语句来定义。 syslog.conf 提供了相当多的用以控制 syslog 如何处理类似 IPF 这样的用用程序所产生的系统消息的方法。 您需要将下列语句加到 /etc/syslog.conf security.* /var/log/ipfilter.log 这里的 security.* 表示把所有的相关日志信息写到指定的文件中。 要让 /etc/syslog.conf 中的修改立即生效, 您可以重新启动计算机, 或者通过执行 /etc/rc.d/syslogd reload 来让它重新读取 /etc/syslog.conf 不要忘了修改 /etc/newsyslog.conf 来让您刚创建的日志进行轮转。 记录消息的格式 ipmon 生成的消息由空格分隔的数据字段组成。 所有的消息都包含的字段是: 接到数据包的日期。 接到数据包的时间。 其格式为 HH:MM:SS.F, 分别是小时、 分钟、 秒, 以及分秒 (这个数字可能有许多位)。 处理数据包的网络接口名字, 例如 dc0 组和规则的编号, 例如 @0:17 可以通过 ipfstat -in 来查看这些信息。 动作: p 表示通过, b 表示阻止, S 表示包头不全, n 表示没有匹配任何规则, L 表示 log 规则。 显示这些标志的顺序是: S, p, b, n, L。 大写的 P 或 B 表示记录包的原因是某个全局的日志配置, 而不是某个特定的规则。 地址。 这实际上包括三部分: 源地址和端口 (以逗号分开), 一个 -> 符号, 以及目的地址和端口。 209.53.17.22,80 -> 198.73.220.17,1722. PR, 后跟协议名称或编号, 例如, PR tcp。 len, 后跟包头的长度, 以及包的总长度, 例如 len 20 40。 对于 TCP 包, 则还会包括一个附加的字段, 由一个连字号开始, 之后是表示所设置的标志的一个字母。 请参见 &man.ipmon.8; 联机手册, 以了解这些字母所对应的标志。 对于 ICMP 包, 则在最后会有两个字段。 前一个总是 ICMP, 而后一个则是 ICMP 消息和子消息的类型, 中间以斜线分靠, 例如 ICMP 3/3 表示端口不可达消息。 构建采用符号替换的规则脚本 一些有经验的 IPF 会创建包含规则的文件, 并把它编写成能够与符号替换脚本兼容的方式。 这样做最大的好处是, 它能够让您只修改符号名字所代表的值, 而在脚本执行时直接替换掉所有的名符。 作为脚本, 您可以使用符号替换来把那些经常使用的值直接用于多个规则。 下面我们将给出一个例子。 这个脚本所使用的语法与 sh、 csh, 以及 tcsh 脚本。 符号替换的前缀字段是美元符号: $ 符号字段不使用 $ 前缀。 希望替换符号字段的值, 必须使用双引号 (") 括起来。 您的规则文件的开头类似这样: ############# IPF 规则脚本的开头 ######################## oif="dc0" # 外网接口的名字 odns="192.0.2.11" # ISP 的 DNS 服务器 IP 地址 myip="192.0.2.7" # 来自 ISP 的静态 IP 地址 ks="keep state" fks="flags S keep state" # 可以使用这个脚本来建立 /etc/ipf.rules 文件, # 也可以 "直接地" 运行它。 # # 请删除两个注释号之一。 # # 1) 保留下面一行, 则创建 /etc/ipf.rules: #cat > /etc/ipf.rules << EOF # # 2) 保留下面一行, 则 "直接地" 运行脚本: /sbin/ipf -Fa -f - << EOF # 允许发出到我的 ISP 的域名服务器的访问 pass out quick on $oif proto tcp from any to $odns port = 53 $fks pass out quick on $oif proto udp from any to $odns port = 53 $ks # 允许发出未加密的 www 访问请求 pass out quick on $oif proto tcp from $myip to any port = 80 $fks # 允许发出使用 TLS SSL 加密的 https www 访问请求 pass out quick on $oif proto tcp from $myip to any port = 443 $fks EOF ################## IPF 规则脚本的结束 ######################## 这就是所需的全部内容。 这个规则本身并不重要, 它们主要是用于体现如何使用符号代换字段, 以及如何完成值的替换。 如果上面的例子的名字是 /etc/ipf.rules.script, 就可以通过输入下面的命令来重新加载规则: &prompt.root; sh /etc/ipf.rules.script 在规则文件中嵌入符号有一个问题: IPF 无法识别符号替换, 因此它不能直接地读取这样的脚本。 这个脚本可以使用下面两种方法之一来使用: 去掉 cat 之前的注释, 并注释掉 /sbin/ipf 开头的那一行。 像其他配置一样, 将 ipfilter_enable="YES" 放到 /etc/rc.conf 文件中, 并在此后立刻执行脚本, 以创建或更新 /etc/ipf.rules 通过把 ipfilter_enable="NO" (这是默认值) 加到 /etc/rc.conf 中, 来禁止系统启动脚本开启 IPFILTER。 /usr/local/etc/rc.d/ 启动目录中增加一个类似下面的脚本。 应该给它起一个显而易见的名字, 例如 ipf.loadrules.sh。 请注意, .sh 扩展名是必需的。 #!/bin/sh sh /etc/ipf.rules.script 脚本文件必须设置为属于 root, 并且属主可读、 可写、 可执行。 &prompt.root; chmod 700 /usr/local/etc/rc.d/ipf.loadrules.sh 这样, 在系统启动时, 就会自动加载您的 IPF 规则了。 IPF 规则集 规则集是指一组编写好的依据包的值决策允许通过或阻止 ipf 规则。 包的双向交换组成了一个会话交互。 防火墙规则集对同一个包会进行两次处理, 第一次是它从公网的 Internet 主机到达的时候, 第二次是它离开并返回初始的 Internet 公网主机的时候。 每一个 TCP/IP 服务 (例如 telnet, www, 邮件等等) 是由协议预先定义的源或目的 IP 地址, 以及源或目的端口。 这是最基本的一些可以为防火墙规则所利用的, 判别是否允许服务通过的标准。 IPFILTER 规则处理顺序 IPF 最初被写成使用一组称作 以最后匹配的规则为准 的处理逻辑, 且只能处理无状态的规则。 随着时代的发展, IPF 进行了改进, 并提供了 quick 选项, 以及一个有状态的 keep state 选项。 后者使处理逻辑迅速地跟上了时代的步伐。 这一节中提供的一些指导, 是基于使用包含 quick 选项和有状态的 keep state 选项来进行阐述的。 这些是编写包容式防火墙规则集的基本要素。 包容式防火墙只允许与规则匹配的服务通过。 这样, 您就既能够控制来自防火墙后面的机器请求 Internet 公网上的那些服务, 同时也可以控制来自 Internet 的请求能够访问内部网上的哪些服务。 所有其它的访问请求都会被阻止, 并记录下来。 包容式防火墙一般而言要远比排斥式的要安全, 而且也只需要定义允许哪些访问通过。 当对防火墙规则进行操作时, 应该 谨慎行事。 某些配置可能会 将您反锁在 服务器外面。 安全起见, 您可以考虑在第一次进行防火墙配置时在本地控制台上, 而不是远程, 例如通过 ssh 来进行。 规则语法 IPFILTER 规则语法 这里给出的规则语法已经简化到只处理那些新式的带状态规则, 并且都是 第一个匹配的规则获胜 逻辑的。 要了解完整的传统规则语法描述, 请参见 &man.ipf.8; 联机手册。 # 字符开头的内容会被认为是注释。 这些注释可以出现在一行规则的末尾, 或者独占一行。 空行会被忽略。 规则由关键字组成。 这些关键字必须以一定的顺序, 从左到右出现在一行上。 接下来的文字中关键字将使用粗体表示。 某些关键字可能提供了子选项, 这些子选项本身可能也是关键字, 而且可能会提供更多的子选项。 下面的文字中, 每种语法都使用粗体的小节标题呈现, 并介绍了其上下文。 ACTION IN-OUT OPTIONS SELECTION STATEFUL PROTO SRC_ADDR,DST_ADDR OBJECT PORT_NUM TCP_FLAG STATEFUL ACTION = block | pass IN-OUT = in | out OPTIONS = log | quick | on 网络接口的名字 SELECTION = proto 协议名称 | 源/目的 IP | port = 端口号 | flags 标志值 PROTO = tcp/udp | udp | tcp | icmp SRC_ADD,DST_ADDR = all | from 对象 to 对象 OBJECT = IP地址 | any PORT_NUM = port 端口号 TCP_FLAG = S STATEFUL = keep state ACTION (动作) 动作对表示匹配规则的包应采取什么动作。 每一个规则 必须 包含一个动作。 可以使用下面两种动作之一: block 表示如果规则与包匹配, 则丢弃包。 pass 表示如果规则与包匹配, 则允许包通过防火墙。 IN-OUT 每个过滤器规则都必须明确地指定是流入还是流出的规则。 下一个关键字必须要么是 in, 要么是 out, 否则将无法通过语法检查。 in 表示规则应被应用于刚刚从 Internet 公网上收到的数据包。 out 表示规则应被应用于即将发出到 Internet 的数据包。 OPTIONS 这些选项必须按下面指定的顺序出现。 log 表示包头应被写入到 ipl 日志 (如前面 LOGGING 小节所介绍的那样), 如果它与规则匹配的话。 quick 表示如果给出的参数与包匹配, 则以这个规则为准, 这使得能够 "短路" 掉后面的规则。 这个选项对于使用新式的处理逻辑是必需的。 on 表示将网络接口的名称作为筛选参数的一部分。 接口的名字会在 &man.ifconfig.8; 的输出中显示。 使用这个选项, 则规则只会应用到某一个网络接口上的出入数据包上。 要配置新式的处理逻辑, 必须使用这个选项。 当记录包时, 包的头会被写入到 IPL 包日志伪设备中。 紧跟 log 关键字, 可以使用下面几个修饰符 (按照下列顺序): body 表示应同时记录包的前 128 字节的内容。 first 如果 log 关键字和 keep state 选项同时使用, 则这个选项只在第一个包上触发, 这样就不用记录每一个 keep state 包信息了。 SELECTION 这一节所介绍的关键字可以用于所检察的包的属性。 有一个关键字主题, 以及一组子选项关键字, 您必须从他们中选择一个。 以下是一些通用的属性, 它们必须按下面的顺序使用: PROTO proto 是一个主题关键字, 它必须与某个相关的子选项关键字配合使用。 这个值的作用是匹配某个特定的协议。 要使用新式的规则处理逻辑, 就必须使用这个选项。 tcp/udp | udp | tcp | icmp 或其他在 /etc/protocols 中定义的协议。 特殊的协议关键字 tcp/udp 可以用于匹配 TCPUDP 包, 引入这个关键字的作用是是避免大量的重复规则的麻烦。 SRC_ADDR/DST_ADDR 使用 all 关键词, 基本上相当于 from any to any 在没有配合其他关键字的情形。 from src to dst: from 和 to 关键字主要是用来匹配 IP 地址。 所有的规则都必须同时给出源和目的两个参数。 any 是一个可以用于匹配任意 IP 地址的特殊关键字。 例如, 您可以使用 from any to anyfrom 0.0.0.0/0 to anyfrom any to 0.0.0.0/0from 0.0.0.0 to any 以及 from any to 0.0.0.0 IP 地址可以按句点分隔的 IP 地址/掩码长度 的方式来指定, 也可以只指定一个句点分隔的 IP 地址。 如果无法使用子网掩码来表示 IP 的话, 表达地址就会很麻烦。 请参见下面的网页了解如何撰写掩码长度: PORT 如果为源或目的指定了匹配端口, 规则就只能应用于 TCPUDP 包了。 当编写端口比较规则时, 可以指定 /etc/services 中所定义的名字, 也可以直接用端口号来指定。 如果端口号出现在源对象一侧, 则被认为是源端口号; 反之, 则被认为是目的端口号。 要使用新式的规则处理逻辑, 就必须与 to 对象配合使用这个选项。 使用的例子: from any to any port = 80 端口的比较是以数字的形式进行的, 可以使用比较算符来指定, 也可以指定一个范围。 port "=" | "!=" | "<" | ">" | "<=" | ">=" | "eq" | "ne" | "lt" | "gt" | "le" | "ge". 要指定端口范围, 可以使用 "<>" | "><"。 在源和目的匹配参数之后, 需要使用下面两个参数, 才能够使用新式的规则处理逻辑。 <acronym>TCP</acronym>_FLAG 标志只对 TCP 过滤使用。 这些字母用来表达 TCP 包头的标志。 新式的规则处理逻辑使用 flags S 参数来识别 tcp 会话开始的请求。 STATEFUL keep state 表示如果有一个包与规则匹配, 则其筛选参数应激活有状态的过滤机制。 如果使用新式的处理逻辑, 则这个选项是必需的。 有状态过滤 IPFILTER 有状态过滤 有状态过滤将网络流量当作一种双向的包交换来处理。 如果激活它, keep-state 会动态地为每一个相关的包在双向会话交互过程中产生内部规则。 它能够确认发起者和包的目的地之间的会话是有效的双向包交换过程的一部分。 如果包与这些规则不符, 则将自动地拒绝。 状态保持也使得 ICMP 包能够与 TCP 或 UDP 会话相关。 因此, 如果您在浏览网站时收到允许的状态保持规则匹配的 ICMP 类型 3 代码 4 响应, 则这些响应会被自动地允许进入。 所有 IPF 能够处理的包, 都可以作为某种活跃会话的一部分, 即使它是另一种协议的, 也会被允许进入。 所发生的事情是: 将要通过联入公网的网络接口发出的包, 首先会经过动态状态表的检查。 如果包与会话中预期的下一个包匹配, 则防火墙就会允许包通过, 而会话的交互流信息也会在动态状态表中进行更新, 而其他的包, 则将使用发出规则集来检查。 发到联入 Internet 公网的包, 也会首先经过动态规则表的检查。 如果与会话中预期的下一个包匹配, 则防火墙就允许它通过, 并更新动态状态表。 其他包仍会使用进入规则集进行检查。 当会话结束时, 对应的项会在动态状态表中删除。 有状态过滤使得您能够集中于阻止/允许新的会话。 一旦新会话被允许通过, 则所有后续的包就都被自动地允许通过, 而伪造的包则被自动地拒绝。 如果新的会话被阻止, 则后续的包也都不会被允许通过。 有状态过滤从技术角度而言, 在阻止目前攻击者常用的洪水式攻击来说, 具有更好的抗御能力。 包容式规则集的例子 下面的规则集是如何编写非常安全的包容式防火墙规则集的一个范例。 包容式防火墙只让允许的服务通过, 而所有其他的访问都会被默认地拒绝。 所有的防火墙都有至少两个接口对应的默认规则, 从而使防火墙能够正常工作。 所有的类 &unix; 系统, 包括 &os; 都使用 lo0 和 IP 地址 127.0.0.1 用于操作系统中内部的通讯。 防火墙规则必须允许这些包无阻碍地通过。 接入 Internet 公网的网络接口, 是放置规则并允许将访问请求发到 Internet 以及接收响应的地方。 这有可能是用户模式的 PPP tun0 接口, 如果您的网卡同 DSL 或电缆调制解调器相联的话。 如果有至少一个网卡与防火墙后的内网 LAN 相联, 这些网络接口就应该有一个规则来允许来自这些 LAN 接口的包无阻碍地通过。 一般说来, 规则应被组织为三个主要的小节: 所有允许自由通过的接口规则, 发到公网接口的规则, 以及进入公网接口的规则。 每一个公网接口规则中, 经常会匹配到的规则应该放置在尽可能靠前的位置。 而最后一个规则应该是阻止包通过, 并记录它们。 下面防火墙规则集中, Outbound 部分是一些使用 'pass' 的规则, 这些规则指定了允许访问的公网 Internet 服务, 并且指定了 'quick'、 'on'、 'proto'、 'port', 以及 'keep state' 这些选项。 'proto tcp' 规则还指定了 'flag' 这个选项, 这样会话的第一个包将出发状态机制。 接下来的 Inbound 一节, 则首先阻止所有不希望的数据包。 这样做有两个原因, 其一是被阻止的包可能会被后面的规则允许, 从而并不妨碍获得授权的服务正常工作; 其二是这避免了那些不常见的包由于匹配到最后一条规则而触发日志, 规则集中的最后一条规则是阻止并记录所有的包, 通过这样的记录, 就比较容易找到攻击系统的人, 并为采取法律措施收集证据。 需要注意的另一件事情是, 如果收到了不希望的数据包, 则这些包会被丢弃, 而不是给出什么响应。 这样做的好处是, 攻击者无法了解包是否已经被您的系统收到。 攻击者所能了解到的信息越少, 攻陷您的系统所需要花费的时间也就越长。 我们在这里记录的连入的 'nmap OS 指纹' 探测企图, 一般来说正是攻击者所做的第一件事。 如果您看到了 'log first' 规则的日志, 就应该用 ipfstat -hio 命令来看看那个规则被匹配的次数, 以便了解系统是否正在或曾被攻击。 如果记录的包的端口号并不是您所知道的, 可以在 /etc/services 了解端口号通常的用途。 参考下面的网页, 了解木马使用的端口: 下面是我在自己的系统中使用的完整的, 非常安全的 '包容式' 防火墙规则集。 直接使用这个规则集不会给您造成问题, 您所要做的只是注释掉那些您不需要的服务。 如果在日志中发现了希望阻止的记录, 只需在 inbound 小节中增加一条阻止规则集可。 您必须将每一个规则中的 dc0 替换为您系统上接入 Internet 的网络接口名称, 例如, 用户环境下的 PPP 应该是 tun0 /etc/ipf.rules 中加入下面的内容: ################################################################# # No restrictions on Inside LAN Interface for private network # Not needed unless you have LAN ################################################################# #pass out quick on xl0 all #pass in quick on xl0 all ################################################################# # No restrictions on Loopback Interface ################################################################# pass in quick on lo0 all pass out quick on lo0 all ################################################################# # Interface facing Public Internet (Outbound Section) # Interrogate session start requests originating from behind the # firewall on the private network # or from this gateway server destine for the public Internet. ################################################################# # Allow out access to my ISP's Domain name server. # xxx must be the IP address of your ISP's DNS. # Dup these lines if your ISP has more than one DNS server # Get the IP addresses from /etc/resolv.conf file pass out quick on dc0 proto tcp from any to xxx port = 53 flags S keep state pass out quick on dc0 proto udp from any to xxx port = 53 keep state # Allow out access to my ISP's DHCP server for cable or DSL networks. # This rule is not needed for 'user ppp' type connection to the # public Internet, so you can delete this whole group. # Use the following rule and check log for IP address. # Then put IP address in commented out rule & delete first rule pass out log quick on dc0 proto udp from any to any port = 67 keep state #pass out quick on dc0 proto udp from any to z.z.z.z port = 67 keep state # Allow out non-secure standard www function pass out quick on dc0 proto tcp from any to any port = 80 flags S keep state # Allow out secure www function https over TLS SSL pass out quick on dc0 proto tcp from any to any port = 443 flags S keep state # Allow out send & get email function pass out quick on dc0 proto tcp from any to any port = 110 flags S keep state pass out quick on dc0 proto tcp from any to any port = 25 flags S keep state # Allow out Time pass out quick on dc0 proto tcp from any to any port = 37 flags S keep state # Allow out nntp news pass out quick on dc0 proto tcp from any to any port = 119 flags S keep state # Allow out gateway & LAN users non-secure FTP ( both passive & active modes) # This function uses the IPNAT built in FTP proxy function coded in # the nat rules file to make this single rule function correctly. # If you want to use the pkg_add command to install application packages # on your gateway system you need this rule. pass out quick on dc0 proto tcp from any to any port = 21 flags S keep state # Allow out secure FTP, Telnet, and SCP # This function is using SSH (secure shell) pass out quick on dc0 proto tcp from any to any port = 22 flags S keep state # Allow out non-secure Telnet pass out quick on dc0 proto tcp from any to any port = 23 flags S keep state # Allow out FBSD CVSUP function pass out quick on dc0 proto tcp from any to any port = 5999 flags S keep state # Allow out ping to public Internet pass out quick on dc0 proto icmp from any to any icmp-type 8 keep state # Allow out whois for LAN PC to public Internet pass out quick on dc0 proto tcp from any to any port = 43 flags S keep state # Block and log only the first occurrence of everything # else that's trying to get out. # This rule enforces the block all by default logic. block out log first quick on dc0 all ################################################################# # Interface facing Public Internet (Inbound Section) # Interrogate packets originating from the public Internet # destine for this gateway server or the private network. ################################################################# # Block all inbound traffic from non-routable or reserved address spaces block in quick on dc0 from 192.168.0.0/16 to any #RFC 1918 private IP block in quick on dc0 from 172.16.0.0/12 to any #RFC 1918 private IP block in quick on dc0 from 10.0.0.0/8 to any #RFC 1918 private IP block in quick on dc0 from 127.0.0.0/8 to any #loopback block in quick on dc0 from 0.0.0.0/8 to any #loopback block in quick on dc0 from 169.254.0.0/16 to any #DHCP auto-config block in quick on dc0 from 192.0.2.0/24 to any #reserved for docs block in quick on dc0 from 204.152.64.0/23 to any #Sun cluster interconnect block in quick on dc0 from 224.0.0.0/3 to any #Class D & E multicast ##### Block a bunch of different nasty things. ############ # That I do not want to see in the log # Block frags block in quick on dc0 all with frags # Block short tcp packets block in quick on dc0 proto tcp all with short # block source routed packets block in quick on dc0 all with opt lsrr block in quick on dc0 all with opt ssrr # Block nmap OS fingerprint attempts # Log first occurrence of these so I can get their IP address block in log first quick on dc0 proto tcp from any to any flags FUP # Block anything with special options block in quick on dc0 all with ipopts # Block public pings block in quick on dc0 proto icmp all icmp-type 8 # Block ident block in quick on dc0 proto tcp from any to any port = 113 # Block all Netbios service. 137=name, 138=datagram, 139=session # Netbios is MS/Windows sharing services. # Block MS/Windows hosts2 name server requests 81 block in log first quick on dc0 proto tcp/udp from any to any port = 137 block in log first quick on dc0 proto tcp/udp from any to any port = 138 block in log first quick on dc0 proto tcp/udp from any to any port = 139 block in log first quick on dc0 proto tcp/udp from any to any port = 81 # Allow traffic in from ISP's DHCP server. This rule must contain # the IP address of your ISP's DHCP server as it's the only # authorized source to send this packet type. Only necessary for # cable or DSL configurations. This rule is not needed for # 'user ppp' type connection to the public Internet. # This is the same IP address you captured and # used in the outbound section. pass in quick on dc0 proto udp from z.z.z.z to any port = 68 keep state # Allow in standard www function because I have apache server pass in quick on dc0 proto tcp from any to any port = 80 flags S keep state # Allow in non-secure Telnet session from public Internet # labeled non-secure because ID/PW passed over public Internet as clear text. # Delete this sample group if you do not have telnet server enabled. #pass in quick on dc0 proto tcp from any to any port = 23 flags S keep state # Allow in secure FTP, Telnet, and SCP from public Internet # This function is using SSH (secure shell) pass in quick on dc0 proto tcp from any to any port = 22 flags S keep state # Block and log only first occurrence of all remaining traffic # coming into the firewall. The logging of only the first # occurrence stops a .denial of service. attack targeted # at filling up your log file space. # This rule enforces the block all by default logic. block in log first quick on dc0 all ################### End of rules file ##################################### <acronym>NAT</acronym> NAT IP 伪装 NAT 网络地址转换 NAT NAT 是 网络地址转换(Network Address Translation) 的缩写。 对于那些熟悉 &linux; 的人来说, 这个概念叫做 IP 伪装 (Masquerading); NAT 和 IP 伪装是完全一样的概念。 由 IPF 的 NAT 提供的一项功能是, 将防火墙后的本地局域网 (LAN) 共享一个 ISP 提供的 IP 地址来接入 Internet 公网。 有些人可能会问, 为什么需要这么做。 一般而言, ISP 会为非商业用户提供动态的 IP 地址。 动态地址意味着每次登录到 ISP 都有可能得到不同的 IP 地址, 无论是采用电话拨号登录, 或使用 cable 以及 DSL 调制解调器的方式。 这个 IP 是您与 Internet 公网交互时使用的身份。 现在考虑家中有五台 PC 需要访问 Internet 的情形。 您可能需要向 ISP 为每一台 PC 所使用的独立的 Internet 账号付费, 并且拥有五根电话线。 有了 NAT, 您就只需要一个 ISP 账号, 然后将另外四台 PC 的网卡通过交换机连接起来, 并通过运行 &os; 系统的那台机器作为网关连接出去。 NAT 会自动地将每一台 PC 在内网的 LAN IP 地址, 在离开防火墙时转换为公网的 IP 地址。 此外, 当数据包返回时, 也将进行逆向的转换。 NAT 通常是在没有向 ISP 请求许可, 或事先知会的情况下进行的, 因而如果被发现, 有时可能会成为 ISP 撤销您的账号的一个借口。 商业用户一般来说会购买昂贵得多的 Internet 线路, 通常会获得一组长期有效的静态 IP 地址块。 ISP 一般会希望并同意商业用户在他们的内网中使用 NAT 在 IP 地址空间中, 有一些特殊的范围是保留供经过 NAT 的内网 LAN IP 地址使用的。 根据 RFC 1918, 您可以使用下面这些 IP 范围用于内网, 它们不会在 Internet 公网上路由: 起始 IP 10.0.0.0 - 结束 IP 10.255.255.255 起始 IP 172.16.0.0 - 结束 IP 172.31.255.255 起始 IP 192.168.0.0 - 结束 IP 192.168.255.255 IP<acronym>NAT</acronym> NAT 以及 IPFILTER ipnat NAT 规则是通过 ipnat 命令加载的。 默认情况下, NAT 规则会保存在 /etc/ipnat.rules 文件中。 请参见 &man.ipnat.1; 了解更多的详情。 如果在 NAT 已经启动之后想要修改 NAT 规则, 可以修改保存 NAT 规则的那个文件, 然后在执行 ipnat 命令时加上 参数, 以删除在用的 NAT 内部规则表, 以及所有地址翻译表中已有的项。 要重新加载 NAT 规则, 可以使用类似下面的命令: &prompt.root; ipnat -CF -f /etc/ipnat.rules 如果想要看看您系统上 NAT 的统计信息, 可以用下面的命令: &prompt.root; ipnat -s 要列出当前的 NAT 表的映射关系, 使用下面的命令: &prompt.root; ipnat -l 要显示详细的信息并显示与规则处理和当前的规则/表项: &prompt.root; ipnat -v IP<acronym>NAT</acronym> 规则 NAT 规则非常的灵活, 能够适应商业用户和家庭用户的各种不同的需求。 这里所介绍的规则语法已经被简化, 以适应非商用环境中的一般情况。 完整的规则语法描述, 请参考 &man.ipnat.5; 联机手册中的介绍。 NAT 规则的写法与下面的例子类似: map IF LAN_IP_RANGE -> PUBLIC_ADDRESS 关键词 map 出现在规则的最前面。 IF 替换为对外的网络接口名。 LAN_IP_RANGE 是内网中的客户机使用的地址范围。 通常情况下, 这应该是类似 192.168.1.0/24 的地址。 PUBLIC_ADDRESS 既可以是外网的 IP 地址, 也可以是 0/32 这个特殊的关键字, 它表示分配到 IF 上的所有地址。 <acronym>NAT</acronym> 的工作原理 当包从 LAN 到达防火墙, 而目的地址是公网地址时, 它首先会通过 outbound 过滤规则。 接下来, NAT 会得到包, 并按自顶向下的顺序处理规则, 而第一个匹配的规则将生效。 NAT 接下来会根据包对应的接口名字和源 IP 地址检查所有的规则。 如果包和某个 NAT 规则匹配, 则会检查包的 [源 IP 地址, 例如, 内网的 IP 地址] 是否在 NAT 规则中箭头左侧指定的 IP 地址范围匹配。 如果匹配, 则包的原地址将被根据用 0/32 关键字指定的 IP 地址重写。 NAT 将向它的内部 NAT 表发送此地址, 这样, 当包从 Internet 公网中返回时, 就能够把地址映射回原先的内网 IP 地址, 并在随后使用过滤器规则来处理。 启用 IP<acronym>NAT</acronym> 要启用 IPNAT, 只需在 /etc/rc.conf 中加入下面一些语句。 使机器能够在不同的网络接口之间进行包的转发, 需要: gateway_enable="YES" 每次开机时自动启动 IPNAT ipnat_enable="YES" 指定 IPNAT 规则集文件: ipnat_rules="/etc/ipnat.rules" 大型 LAN 中的 <acronym>NAT</acronym> 对于在一个 LAN 中有大量 PC, 以及包含多个 LAN 的情形, 把所有的内网 IP 地址都映射到同一个公网 IP 上会导致资源不够的问题, 因为同一个端口可能在许多做了 NAT 的 LAN PC 上被多次使用, 并导致碰撞。 有两种方法来缓解这个难题。 指定使用哪些端口 普通的 NAT 规则类似于: map dc0 192.168.1.0/24 -> 0/32 上面的规则中, 包的源端口在包通过 IPNAT 时时不会发生变化的。 通过使用 portmap 关键字, 您可以要求 IPNAT 只使用一定范围内的端口地址。 比如说, 下面的规则将让 IPNAT 把源端口改为指定范围内的端口: map dc0 192.168.1.0/24 -> 0/32 portmap tcp/udp 20000:60000 使用 auto 关键字可以让配置变得更简单一些, 它会要求 IPNAT 自动地检测可用的端口并使用: map dc0 192.168.1.0/24 -> 0/32 portmap tcp/udp auto 使用公网地址池 对很大的 LAN 而言, 总有一天会达到这样一个临界值, 此时的 LAN 地址已经多到了无法只用一个公网地址表现的程度。 如果有可用的一块公网 IP 地址, 则可以将这些地址作为一个 地址池 来使用, 让 IPNAT 来从这些公网 IP 地址中挑选用于发包的地址, 并将其为这些包创建映射关系。 例如, 如果将下面这个把所有包都映射到同一公网 IP 地址的规则: map dc0 192.168.1.0/24 -> 204.134.75.1 稍作修改, 就可以用子网掩码来表达 IP 地址范围: map dc0 192.168.1.0/24 -> 204.134.75.0/255.255.255.0 或者用 CIDR 记法来指定的一组地址了: map dc0 192.168.1.0/24 -> 204.134.75.0/24 端口重定向 非常流行的一种做法是, 将 web 服务器、 邮件服务器、 数据库服务器以及 DNS 分别放到 LAN 上的不同的 PC 上。 这种情况下, 来自这些服务器的网络流量仍然应该被 NAT, 但必须有办法把进入的流量发到对应的局域网的 PC 上。 IPNAT 提供了 NAT 重定向机制来解决这个问题。 考虑下面的情况, 您的 web 服务器的 LAN 地址是 10.0.10.25, 而您的唯一的公网 IP 地址是 20.20.20.5, 则可以编写这样的规则: rdr dc0 20.20.20.5/32 port 80 -> 10.0.10.25 port 80 或者: rdr dc0 0.0.0.0/0 port 80 -> 10.0.10.25 port 80 另外, 也可以让 LAN 地址 10.0.10.33 上运行的 LAN DNS 服务器来处理公网上的 DNS 请求: rdr dc0 20.20.20.5/32 port 53 -> 10.0.10.33 port 53 udp FTP 和 <acronym>NAT</acronym> FTP 是一个在 Internet 如今天这样为人所熟知之前就已经出现的恐龙, 那时, 研究机构和大学是通过租用的线路连到一起的, 而 FTP 则被用于在科研人员之间共享大文件。 那时, 数据的安全性并不是需要考虑的事情。 若干年之后, FTP 协议则被埋进了正在形成中的 Internet 骨干, 而它使用明文来交换用户名和口令的缺点, 并没有随着新出现的一些安全需求而得到改变。 FTP 提供了两种不同的风格, 即主动模式和被动模式。 两者的区别在于数据通道的建立方式。 被动模式相对而言要更加安全, 因为数据通道是由发起 ftp 会话的一方建立的。 关于 FTP 以及它所提供的不同模式, 在 进行了很好的阐述。 IP<acronym>NAT</acronym> 规则 IPNAT 提供了一个内建的 FTP 代理选项, 它可以在 NAT map 规则中指定。 它能够监视所有外发的 FTP 主动或被动模式的会话开始请求, 并动态地创建临时性的过滤器规则, 只打开用于数据通道的端口号。 这样, 就消除了 FTP 一般会给防火墙带来的, 需要大范围地打开高端口所可能带来的安全隐患。 下面的规则可以处理来自内网的 FTP 访问: map dc0 10.0.10.0/29 -> 0/32 proxy port 21 ftp/tcp 这个规则能够处理来自网关的 FTP 访问: map dc0 0.0.0.0/0 -> 0/32 proxy port 21 ftp/tcp 这个则处理所有来自内网的非 FTP 网络流量: map dc0 10.0.10.0/29 -> 0/32 FTP map 规则应该在普通的 map 规则之前出现。 所有的包会从最上面的第一个规则开始进行检查。 匹配的顺序是网卡名称, 内网源 IP 地址, 以及它是否是 FTP 包。 如果所有这些规则都匹配成功, 则 FTP 代理将建立一个临时的过滤规则, 以便让 FTP 会话的数据包能够正常出入, 同时对这些包进行 NAT。 所有的 LAN 数据包, 如果没有匹配第一条规则, 则会继续尝试匹配下面的规则, 并最终被 NAT IP<acronym>NAT</acronym> FTP 过滤规则 如果使用了 NAT FTP 代理, 则只需要为 FTP 创建一个规则。 如果没有使用 FTP 代理, 则需要下面三个规则: # Allow out LAN PC client FTP to public Internet # Active and passive modes pass out quick on rl0 proto tcp from any to any port = 21 flags S keep state # Allow out passive mode data channel high order port numbers pass out quick on rl0 proto tcp from any to any port > 1024 flags S keep state # Active mode let data channel in from FTP server pass in quick on rl0 proto tcp from any to any port = 20 flags S keep state IPFW 防火墙 IPFW - - 这一节的内容正在撰写中。 其内容可能不总是十分准确。 - - IPFIREWALL (IPFW) 是一个由 &os; 发起的防火墙应用软件, 它由 &os; 的志愿者成员编写和维护。 它使用了传统的无状态规则和规则编写方式, 以期达到简单状态逻辑所期望的目标。 标准的 &os; 安装中, IPFW 所给出的规则集样例 (可以在 - /etc/rc.firewall 中找到) 非常简单, + /etc/rc.firewall 和 + /etc/rc.firewall6 中找到) 非常简单, 建议不要不加修改地直接使用。 该样例中没有使用状态过滤, 而该功能在大部分的配置中都是非常有用的, 因此这一节并不以系统自带的样例作为基础。 IPFW 的无状态规则语法, 是由一种提供复杂的选择能力的技术支持的, 这种技术远远超出了一般的防火墙安装人员的知识水平。 IPFW 是为满足专业用户, 以及掌握先进技术的电脑爱好者们对于高级的包选择需求而设计的。 要完全释放 IPFW 的规则所拥有的强大能力, 需要对不同的协议的细节有深入的了解, 并根据它们独特的包头信息来编写规则。 这一级别的详细阐述超出了这本手册的范围。 IPFW 由七个部分组成, 其主要组件是内核的防火墙过滤规则处理器, 及其集成的数据包记帐工具、 日志工具、 用以触发 NAT 工具的 'divert' (转发) 规则、 高级特殊用途工具、 dummynet 流量整形机制, - 'fwd rule' 转发工具, 桥接工具, 以及 ipstealth 工具。 + 'fwd rule' 转发工具, 桥接工具, 以及 ipstealth 工具。 + IPFW 支持 IPv4 和 IPv6。 启用 IPFW IPFW 启用 IPFW 是基本的 &os; 安装的一部分, 以单独的可加载内核模块的形式提供。 如果在 rc.conf 中加入 firewall_enable="YES" 语句, 就会自动地加载对应的内核模块。 除非您打算使用由它提供的 NAT 功能, 一般情况下并不需要把 IPFW 编进 &os; 的内核。 如果将 firewall_enable="YES" 加入到 rc.conf 中并重新启动系统, 则下列信息将在启动过程中, 以高亮的白色显示出来: ipfw2 initialized, divert disabled, rule-based forwarding disabled, default to deny, logging disabled 可加载内核模块在编译时加入了记录日志的能力。 要启用日志功能, 并配置详细日志记录的限制, 需要在 /etc/sysctl.conf 中加入一些配置。 这些设置将在重新启动之后生效: net.inet.ip.fw.verbose=1 net.inet.ip.fw.verbose_limit=5 内核选项 内核选项 IPFIREWALL 内核选项 IPFIREWALL_VERBOSE 内核选项 IPFIREWALL_VERBOSE_LIMIT IPFW 内核选项 把下列选项在编译 &os; 内核时就加入, 并不是启用 IPFW 所必需的, 除非您需要使用 NAT 功能。 这里只是将这些选项作为背景知识来介绍。 options IPFIREWALL 这个选项将 IPFW 作为内核的一部分来启用。 options IPFIREWALL_VERBOSE 这个选项将启用记录通过 IPFW 的匹配了包含 'log' 关键字规则的每一个包的功能。 options IPFIREWALL_VERBOSE_LIMIT=5 以每项的方式, 限制通过 &man.syslogd.8; 记录的包的个数。 如果在比较恶劣的环境下记录防火墙的活动可能会需要这个选项。 它能够避免潜在的针对 syslog 的洪水式拒绝服务攻击。 内核选项 IPFIREWALL_DEFAULT_TO_ACCEPT options IPFIREWALL_DEFAULT_TO_ACCEPT 这个选项默认地允许所有的包通过防火墙, 如果您是第一次配置防火墙, 使用这个选项将是一个不错的主意。 - options IPV6FIREWALL -options IPV6FIREWALL_VERBOSE -options IPV6FIREWALL_VERBOSE_LIMIT -options IPV6FIREWALL_DEFAULT_TO_ACCEPT - - 这些选项与 IPv4 的对应选项功能一样, 它们是针对 IPv6 - 的。 如果不使用 IPv6, 则不带任何规则的 IPV6FIREWALL - 将阻止所有的 IPv6 包。 - 内核选项 IPDIVERT options IPDIVERT 这一选项启用 NAT 功能。 如果内核选项中没有加入 IPFIREWALL_DEFAULT_TO_ACCEPT, 或将您的防火墙设置配置为允许所有的进入包, 则所有发到本机或发出的包都会被阻止。 <filename>/etc/rc.conf</filename> Options 启用防火墙: firewall_enable="YES" 要选择由 &os; 提供的几种防火墙类型中的一种来作为默认配置, 您需要阅读 /etc/rc.firewall 文件并选出合适的类型, 然后在 /etc/rc.conf 中加入类似下面的配置: firewall_type="open" 您还可以指定下列配置规则之一: open — 允许所有流量通过。 client — 只保护本机。 simple — 保护整个网络。 closed — 完全禁止除回环设备之外的全部 IP 流量。 UNKNOWN — 禁止加载防火墙规则。 filename — 到防火墙规则文件的绝对路径。 有两种加载自定义 ipfw 防火墙规则的方法。 其一是将变量 firewall_type 设为包含不带 &man.ipfw.8; 命令行选项的 防火墙规则 文件的完整路径。 下面是一个简单的规则集例子: add block in all add block out all 除此之外, 也可以将 firewall_script 变量设为包含 ipfw 命令的可执行脚本, 这样这个脚本会在启动时自动执行。 与前面规则集文件等价的规则脚本如下: #!/bin/sh ipfw -q flush ipfw add block in all ipfw add block out all 如果 firewall_type 设为 clientsimple, 则还应查看在 /etc/rc.firewall 中的默认规则, 以确认它们与所在机器的配置相一致。 此外, 请注意这一章中的例子均假定 firewall_script/etc/ipfw.rules 启用日志: firewall_logging="YES" 设置 firewall_logging 的唯一作用是, 系统将把 net.inet.ip.fw.verbose sysctl 变量置为 1 (参见 )。 并没有能够设置日志限制的 rc.conf 变量, 不过这种限制可以通过设置某些 sysctl 变量来完成, 可以手工进行操作, 也可以写到 /etc/sysctl.conf 文件中: net.inet.ip.fw.verbose_limit=5 如果您的计算机是作为网关使用的, 也就是它通过 &man.natd.8; 提供网络地址翻译 (NAT), 请参见 以了解需要在 /etc/rc.conf 中配置的选项。 IPFW 命令 ipfw ipfw 命令是在防火墙运行时, 用于在其内部规则表中手工逐条添加或删除防火墙规则的标准工具。 这一方法的问题在于, 一旦您的关闭计算机或停机, 则所有增加或删除或修改的规则也就丢掉了。 把所有的规则都写到一个文件中, 并在启动时使用这个文件来加载规则, 或一次大批量地替换防火墙规则, 那么推荐使用这里介绍的方法。 ipfw 的另一个非常实用的功能是将所有正在运行的防火墙规则显示出来。 IPFW 的记账机制会为每一个规则动态地创建计数器, 用以记录与它们匹配的包的数量。 在测试规则的过程中, 列出规则及其计数器是了解它们是否工作正常的重要手段。 按顺序列出所有的规则: &prompt.root; ipfw list 列出所有的规则, 同时给出最后一次匹配的时间戳: &prompt.root; ipfw -t list 列出所有的记账信息、 匹配规则的包的数量, 以及规则本身。 第一列是规则的编号, 随后是发出包匹配的数量, 进入包的匹配数量, 最后是规则本身。 &prompt.root; ipfw -a list 列出所有的动态规则和静态规则: &prompt.root; ipfw -d list 同时显示已过期的动态规则: &prompt.root; ipfw -d -e list 将计数器清零: &prompt.root; ipfw zero 只把规则号为 NUM 的计数器清零: &prompt.root; ipfw zero NUM IPFW 规则集 规则集是一组根据包中选择的数值使用 allow 或 deny 写出的 ipfw 规则。 在两个主机之前的双向包交换组成了一次会话交互。 防火墙规则集, 会对同一个包处理两次: 第一次是包从公网上到达防火墙时, 而第二次则是包返回 Internet 公网上的主机时。 每一个 TCP/IP 服务 (例如 telnet, www, mail, 等等), 都有事先定义好的协议, 以及一个端口号。 这可以作为建立允许或阻止规则时的基本选择依据。 IPFW 规则处理顺序 当有数据包进入防火墙时, 会从规则集里的第一个规则开始进行比较, 并自顶向下地进行匹配。 当包与某个选择规则参数相匹配时, 将会执行规则所定义的动作, 并停止规则集搜索。 这种策略, 通常也被称作 最先匹配者获胜 的搜索方法。 如果没有任何与包相匹配的规则, 那么它就会根据强制的 ipfw 默认规则, 也就是 65535 号规则截获。 一般情况下这个规则是阻止包, 而且不给出任何回应。 如果规则定义的动作是 countskiptotee 规则的话, 搜索会继续。 这里所介绍的规则, 都是使用了那些包含状态功能的, 也就是 'keep state'、 'limit'、 'in'/'out'、 或者 'via' 选项的规则。 这是编写包容式防火墙规则集所需的基本框架。 包容式防火墙只允许与规则匹配的包通过。 这样, 您就既能够控制来自防火墙后面的机器请求 Internet 公网上的那些服务, 同时也可以控制来自 Internet 的请求能够访问内部网上的哪些服务。 所有其它的访问请求都会被阻止, 并记录下来。 包容式防火墙一般而言要远比排斥式的要安全, 而且也只需要定义允许哪些访问通过。 在操作防火墙规则时应谨慎行事, 如果操作不当, 有可能将自己反锁在外面。 规则语法 IPFW 规则语法 这里所介绍的规则语法已经经过了简化, 只包括了建立标准的包容式防火墙规则集所必需的那些。 要了解完整的规则语法说明, 请参见 &man.ipfw.8; 联机手册。 规则是由关键字组成的: 这些关键字必须以特定的顺序从左到右书写。 下面的介绍中, 关键字使用粗体表示。 某些关键字还包括了子选项, 这些子选项本身可能也是关键字, 有些还可以包含更多的子选项。 # 用于表示开始一段注释。 它可以出现在一个规则的后面, 也可以独占一行。 空行会被忽略。 CMD RULE_NUMBER ACTION LOGGING SELECTION STATEFUL CMD 每一个新的规则都应以 add 作为前缀, 它表示将规则加入内部表。 RULE_NUMBER 每一个规则都必须包含一个规则编号。 ACTION 每一个规则可以与下列的动作之一相关联, 所指定的动作将在进入的数据包与规则所指定的选择标准相匹配时执行。 allow | accept | pass | permit 这些关键字都表示允许匹配规则的包通过防火墙, 并停止继续搜索规则。 check-state 根据动态规则表检查数据包。 如果匹配, 则执行规则所指定的动作, 亦即生成动态规则; 否则, 转移到下一个规则。 check-state 规则没有选择标准。 如果规则集中没有 check-state 规则, 则会在第一个 keep-state 或 limit 规则处, 对动态规则表实施检查。 deny | drop 这两个关键字都表示丢弃匹配规则的包。 同时, 停止继续搜索规则。 LOGGING log or logamount 当数据包与带 log 关键字的规则匹配时, 将通过名为 SECURITY 的 facility 来把消息记录到 syslogd。 只有在记录的次数没有超过 logamount 参数所指定的次数时, 才会记录日志。 如果没有指定 logamount, 则会以 sysctl 变量 net.inet.ip.fw.verbose_limit 所指定的限制为准。 如果将这两种限制值之一指定为零, 则表示不作限制。 万一达到了限制数, 可以通过将规则的日志计数或包计数清零来重新启用日志, 请参见 ipfw reset log 命令来了解细节。 日志是在所有其他匹配条件都验证成功之后, 在针对包实施最终动作 (accept, deny) 之前进行的。 您可以自行决定哪些规则应启用日志。 SELECTION 这一节所介绍的关键字主要用来描述检查包的哪些属性, 用以判断包是否与规则相匹配。 下面是一些通用的用于匹配包特征的属性, 它们必须按顺序使用: udp | tcp | icmp 也可以指定在 /etc/protocols 中所定义的协议。 这个值定义的是匹配的协议, 在规则中必须指定它。 from src to dst from 和 to 关键字用于匹配 IP 地址。 规则中必须同时指定源和目的两个参数。 如果需要匹配任意 IP 地址, 可以使用特殊关键字 any。 还有一个特殊关键字, 即 me, 用于匹配您的 &os; 系统上所有网络接口上所配置的 IP 地址, 它可以用于表达网络上的其他计算机到防火墙 (也就是本机), 例如 'from me to any' 或 'from any to me' 或 'from 0.0.0.0/0 to any' 或 'from any to 0.0.0.0/0' 或 'from 0.0.0.0 to any' 或 'from any to 0.0.0.0' 以及 'from me to 0.0.0.0'。 IP 地址可以通过 带点的 IP 地址/掩码长度, 或者一个带点的 IP 地址的形式来指定。 这是编写规则时所必需的。 如果不清楚如何写掩码长度, 请参见 port number 这个参数主要用于那些支持端口号的协议 (例如 TCP 和 UDP)。 如果要通过端口号匹配某个协议, 就必须指定这个参数。 此外, 也可以通过服务的名字 (根据 /etc/services) 来指定服务, 这样会比使用数字指定端口号直观一些。 in | out 相应地, 匹配进入和发出的包。 这里的 in 和 out 都是关键字, 在编写匹配规则时, 必需作为其他条件的一部分来使用。 via IF 根据指定的网络接口的名称精确地匹配进出的包。 这里的 via 关键字将使得接口名称成为匹配过程的一部分。 setup 要匹配 TCP 会话的发起请求, 就必须使用它。 keep-state 这是一个必须使用的关键字。 在发生匹配时, 防火墙将创建一个动态规则, 其默认行为是, 匹配使用同一协议的、从源到目的 IP/端口 的双向网络流量。 limit {src-addr | src-port | dst-addr | dst-port} 防火墙只允许匹配规则时, 与指定的参数相同的 N 个连接。 可以指定至少一个源或目的地址及端口。 'limit' 和 'keep-state' 不能在同一规则中同时使用。 'limit' 提供了与 'keep-state' 相同的功能, 并增加了一些独有的能力。 状态规则选项 IPFW 带状态过滤 有状态过滤将网络流量当作一种双向的包交换来处理。 它提供了一种额外的检查能力, 用以检测会话中的包是否来自最初的发送者, 并在遵循双向包交换的规则进行会话。 如果包与这些规则不符, 则将自动地拒绝它们。 'check-state' 用来识别在 IPFW 规则集中的包是否符合动态规则机制的规则。 如果匹配, 则允许包通过, 此时防火墙将创建一个新的动态规则来匹配双向交换中的下一个包。 如果不匹配, 则将继续尝试规则集中的下一个规则。 动态规则机制在 SYN-flood 攻击下是脆弱的, 因为这种情况会产生大量的动态规则, 从而耗尽资源。 为了抵抗这种攻击, 从 &os; 中加入了一个叫做 limit 的新选项。 这个选项可以用来限制符合规则的会话允许的并发连接数。 如果动态规则表中的规则数超过限制, 则包将被丢弃。 记录防火墙消息 IPFW 记录日志 记录日志的好处是显而易见的: 它提供了在事后检查所发生的状况的方法, 例如哪些包被丢弃了, 这些包的来源和目的地, 从而为您提供找到攻击者所需的证据。 即使启用了日志机制, IPFW 也不会自行生成任何规则的日志。 防火墙管理员需要指定规则集中的哪些规则应该记录日志, 并在这些规则上增加 log 动作。 一般来说, 只有 deny 规则应记录日志, 例如对于进入的 ICMP ping 的 deny 规则。 另外, 复制默认的 ipfw 终极 deny 规则, 并加入 log 动作来作为您的规则集的最后一条规则也是很常见的用法。 这样, 您就能看到没有匹配任何一条规则的那些数据包。 日志是一把双刃剑, 如果不谨慎地加以利用, 则可能会陷入过多的日志数据中, 并导致磁盘被日志塞满。 将磁盘填满是 DoS 攻击最为老套的手法之一。 由于日志除了会写入磁盘之外, 还会输出到 root 的控制台屏幕上, 因此有过多的日志信息是很让人恼火的事情。 IPFIREWALL_VERBOSE_LIMIT=5 内核选项将限制同一个规则发到系统日志程序 syslogd 的连续消息的数量。 当内核启用了这个选项时, 某一特定规则所产生的连续消息的数量将封顶为这个数字。 一般来说, 没有办法从连续 200 条一模一样的日志信息中获取更多有用的信息。 举例来说, 如果同一个规则产生了 5 次消息并被记录到 syslogd, 余下的相同的消息将被计数, 并像下面这样发给 syslogd: last message repeated 45 times 所有记录的数据包包消息, 默认情况下会最终写到 /var/log/security 文件中, 后者在 /etc/syslog.conf 文件里进行了定义。 编写规则脚本 绝大多数有经验的 IPFW 用户会创建一个包含规则的文件, 并且, 按能够以脚本形式运行的方式来书写。 这样做最大的一个好处是, 可以大批量地刷新防火墙规则, 而无须重新启动系统就能够激活它们。 这种方法在测试新规则时会非常方便, 因为同一过程在需要时可以多次执行。 作为脚本, 您可以使用符号替换来撰写那些经常需要使用的值, 并用同一个符号在多个规则中反复地表达它。 下面将给出一个例子。 这个脚本使用的语法同 'sh'、 'csh' 以及 'tcsh' 脚本兼容。 符号替换字段使用美元符号 $ 作为前缀。 符号字段本身并不使用 $ 前缀。 符号替换字段的值必须使用 "双引号" 括起来。 可以使用类似下面的规则文件: ############### start of example ipfw rules script ############# # ipfw -q -f flush # Delete all rules # Set defaults oif="tun0" # out interface odns="192.0.2.11" # ISP's DNS server IP address cmd="ipfw -q add " # build rule prefix ks="keep-state" # just too lazy to key this each time $cmd 00500 check-state $cmd 00502 deny all from any to any frag $cmd 00501 deny tcp from any to any established $cmd 00600 allow tcp from any to any 80 out via $oif setup $ks $cmd 00610 allow tcp from any to $odns 53 out via $oif setup $ks $cmd 00611 allow udp from any to $odns 53 out via $oif $ks ################### End of example ipfw rules script ############ 这就是所要做的全部事情了。 例子中的规则并不重要, 它们主要是用来表示如何使用符号替换。 如果把上面的例子保存到 /etc/ipfw.rules 文件中, 您就可以通过输入下面的命令来加载它。 &prompt.root; sh /etc/ipfw.rules /etc/ipfw.rules 这个文件可以放到任何位置, 也可以命名为随便什么别的名字。 也可以手工执行下面的命令来达到类似的目的: &prompt.root; ipfw -q -f flush &prompt.root; ipfw -q add check-state &prompt.root; ipfw -q add deny all from any to any frag &prompt.root; ipfw -q add deny tcp from any to any established &prompt.root; ipfw -q add allow tcp from any to any 80 out via tun0 setup keep-state &prompt.root; ipfw -q add allow tcp from any to 192.0.2.11 53 out via tun0 setup keep-state &prompt.root; ipfw -q add 00611 allow udp from any to 192.0.2.11 53 out via tun0 keep-state 带状态规则集 以下的这组非-NAT 规则集, 是如何编写非常安全的 '包容式' 防火墙的一个例子。 包容式防火墙只允许匹配了 pass 规则的包通过, 而默认阻止所有的其他数据包。 必须有至少两个网络接口, 并且在其上配置了规则才能使防火墙正常工作。 所有类 &unix; 操作系统, 也包括 &os;, 都设计为允许使用网络接口 lo0 和 IP 地址 127.0.0.1 来完成操作系统内部的通讯。 防火墙必须包含一组规则, 使这些数据包能够无障碍地收发。 接入 Internet 公网的那个网络接口上, 应该配置授权和访问控制, 来限制对外的访问, 以及来自 Internet 公网的访问。 这个接口很可能是您的 ppp 接口, 例如 tun0, 或者您接在 DSL 或电缆 modem 上的网卡。 如果有至少一个网卡接入了防火墙后的内网 LAN, 则必须为这些接口配置规则, 以便让这些接口之间的包能够顺畅地通过。 所有的规则应被组织为三个部分, 所有应无阻碍地通过的规则, 公网的发出规则, 以及公网的接收规则。 公网接口相关的规则的顺序, 应该是最经常用到的放在尽可能靠前的位置, 而最后一个规则, 则应该是阻止那个接口在那一方向上的包。 发出部分的规则只包含一些 'allow' 规则, 允许选定的那些唯一区分协议的端口号所指定的协议通过, 以允许访问 Internet 公网上的这些服务。 所有的规则中都指定了 proto, port, in/out, via 以及 keep state 这些选项。 'proto tcp' 规则同时指定 'setup' 选项, 来区分开始协议会话的包, 以触发将包放入 keep state 规则表中的动作。 接收部分则首先阻止所有不希望的包, 在这里有两个目的。 首先是, 这些包被禁止掉之后, 就不会由于匹配了后面的某个规则而被允许。 其次, 明确地禁止这些包, 就不会再在日志中记录它们而形成干扰。 防火墙的最后一条规则是阻止并记录所有包, 这样, 您就可以留下用于起诉攻击您的系统的人的有用记录。 另一件需要注意的事情是, 不希望的数据包一般来说不会有任何响应, 这些数据包会被丢弃并消失。 这样, 攻击者也就无法了解他的数据包是否到达了您的系统。 而攻击者了解的信息越少, 它们攻陷系统所需的时间也就越长。 当记录的包使用的端口号不是您所熟悉的那些时, 可以看一看 /etc/services/ 或到 并查找一下端口号, 以了解其用途。 另外, 您也可以在这个网页上了解常见木马所使用的端口: 包容式规则集的例子 下面是一个非-NAT 的规则集, 它是一个完整的包容式规则集。 使用它作为您的规则集不会有什么问题。 只需把那些不需要的服务对应的 pass 规则注释掉就可以了。 如果您在日志中看到消息, 而且不想再看到它们, 只需在接收部分增加一个一个 deny 规则。 您可能需要把 'dc0' 改为接入公网的接口的名字。 对于使用用户态 ppp 的用户而言, 应该是 'tun0'。 您可以看出这些规则中的模式。 所有请求 Internet 公网上服务的会话开始包, 都使用了 keep-state。 所有来自 Internet 的授权服务请求, 都采用了 limit 选项来防止洪水式攻击。 所有的规则都使用了 in 或者 out 来说明方向。 所有的规则都使用了 via 接口名来指定应该匹配通过哪一个接口的包。 这些规则都应放到 /etc/ipfw.rules ################ Start of IPFW rules file ############################### # Flush out the list before we begin. ipfw -q -f flush # Set rules command prefix cmd="ipfw -q add" pif="dc0" # public interface name of NIC # facing the public Internet ################################################################# # No restrictions on Inside LAN Interface for private network # Not needed unless you have LAN. # Change xl0 to your LAN NIC interface name ################################################################# #$cmd 00005 allow all from any to any via xl0 ################################################################# # No restrictions on Loopback Interface ################################################################# $cmd 00010 allow all from any to any via lo0 ################################################################# # Allow the packet through if it has previous been added to the # the "dynamic" rules table by a allow keep-state statement. ################################################################# $cmd 00015 check-state ################################################################# # Interface facing Public Internet (Outbound Section) # Interrogate session start requests originating from behind the # firewall on the private network or from this gateway server # destine for the public Internet. ################################################################# # Allow out access to my ISP's Domain name server. # x.x.x.x must be the IP address of your ISP.s DNS # Dup these lines if your ISP has more than one DNS server # Get the IP addresses from /etc/resolv.conf file $cmd 00110 allow tcp from any to x.x.x.x 53 out via $pif setup keep-state $cmd 00111 allow udp from any to x.x.x.x 53 out via $pif keep-state # Allow out access to my ISP's DHCP server for cable/DSL configurations. # This rule is not needed for .user ppp. connection to the public Internet. # so you can delete this whole group. # Use the following rule and check log for IP address. # Then put IP address in commented out rule & delete first rule $cmd 00120 allow log udp from any to any 67 out via $pif keep-state #$cmd 00120 allow udp from any to x.x.x.x 67 out via $pif keep-state # Allow out non-secure standard www function $cmd 00200 allow tcp from any to any 80 out via $pif setup keep-state # Allow out secure www function https over TLS SSL $cmd 00220 allow tcp from any to any 443 out via $pif setup keep-state # Allow out send & get email function $cmd 00230 allow tcp from any to any 25 out via $pif setup keep-state $cmd 00231 allow tcp from any to any 110 out via $pif setup keep-state # Allow out FBSD (make install & CVSUP) functions # Basically give user root "GOD" privileges. $cmd 00240 allow tcp from me to any out via $pif setup keep-state uid root # Allow out ping $cmd 00250 allow icmp from any to any out via $pif keep-state # Allow out Time $cmd 00260 allow tcp from any to any 37 out via $pif setup keep-state # Allow out nntp news (i.e. news groups) $cmd 00270 allow tcp from any to any 119 out via $pif setup keep-state # Allow out secure FTP, Telnet, and SCP # This function is using SSH (secure shell) $cmd 00280 allow tcp from any to any 22 out via $pif setup keep-state # Allow out whois $cmd 00290 allow tcp from any to any 43 out via $pif setup keep-state # deny and log everything else that.s trying to get out. # This rule enforces the block all by default logic. $cmd 00299 deny log all from any to any out via $pif ################################################################# # Interface facing Public Internet (Inbound Section) # Interrogate packets originating from the public Internet # destine for this gateway server or the private network. ################################################################# # Deny all inbound traffic from non-routable reserved address spaces $cmd 00300 deny all from 192.168.0.0/16 to any in via $pif #RFC 1918 private IP $cmd 00301 deny all from 172.16.0.0/12 to any in via $pif #RFC 1918 private IP $cmd 00302 deny all from 10.0.0.0/8 to any in via $pif #RFC 1918 private IP $cmd 00303 deny all from 127.0.0.0/8 to any in via $pif #loopback $cmd 00304 deny all from 0.0.0.0/8 to any in via $pif #loopback $cmd 00305 deny all from 169.254.0.0/16 to any in via $pif #DHCP auto-config $cmd 00306 deny all from 192.0.2.0/24 to any in via $pif #reserved for docs $cmd 00307 deny all from 204.152.64.0/23 to any in via $pif #Sun cluster interconnect $cmd 00308 deny all from 224.0.0.0/3 to any in via $pif #Class D & E multicast # Deny public pings $cmd 00310 deny icmp from any to any in via $pif # Deny ident $cmd 00315 deny tcp from any to any 113 in via $pif # Deny all Netbios service. 137=name, 138=datagram, 139=session # Netbios is MS/Windows sharing services. # Block MS/Windows hosts2 name server requests 81 $cmd 00320 deny tcp from any to any 137 in via $pif $cmd 00321 deny tcp from any to any 138 in via $pif $cmd 00322 deny tcp from any to any 139 in via $pif $cmd 00323 deny tcp from any to any 81 in via $pif # Deny any late arriving packets $cmd 00330 deny all from any to any frag in via $pif # Deny ACK packets that did not match the dynamic rule table $cmd 00332 deny tcp from any to any established in via $pif # Allow traffic in from ISP's DHCP server. This rule must contain # the IP address of your ISP.s DHCP server as it.s the only # authorized source to send this packet type. # Only necessary for cable or DSL configurations. # This rule is not needed for .user ppp. type connection to # the public Internet. This is the same IP address you captured # and used in the outbound section. #$cmd 00360 allow udp from any to x.x.x.x 67 in via $pif keep-state # Allow in standard www function because I have apache server $cmd 00400 allow tcp from any to me 80 in via $pif setup limit src-addr 2 # Allow in secure FTP, Telnet, and SCP from public Internet $cmd 00410 allow tcp from any to me 22 in via $pif setup limit src-addr 2 # Allow in non-secure Telnet session from public Internet # labeled non-secure because ID & PW are passed over public # Internet as clear text. # Delete this sample group if you do not have telnet server enabled. $cmd 00420 allow tcp from any to me 23 in via $pif setup limit src-addr 2 # Reject & Log all incoming connections from the outside $cmd 00499 deny log all from any to any in via $pif # Everything else is denied by default # deny and log all packets that fell through to see what they are $cmd 00999 deny log all from any to any ################ End of IPFW rules file ############################### 一个 <acronym>NAT</acronym> 和带状态规则集的例子 NAT 以及 IPFW 要使用 IPFW 的 NAT 功能, 还需要进行一些额外的配置。 除了其他 IPFIREWALL 语句之外, 还需要在内核编译配置中加上 'option IPDIVERT' 语句。 /etc/rc.conf 中, 除了普通的 IPFW 配置之外, 还需要加入: natd_enable="YES" # Enable NATD function natd_interface="rl0" # interface name of public Internet NIC natd_flags="-dynamic -m" # -m = preserve port numbers if possible 将带状态规则与转发 natd 规则 (网络地址转换) 会使规则集的编写变得非常复杂。 check-state 的位置, 以及 'divert natd' 规则将变得非常关键。 这样一来, 就不再有简单的顺序处理逻辑流程了。 提供了一种新的动作类型, 称为 'skipto'。 要使用 skipto 命令, 就必须给每一个规则进行编号, 以确定 skipto 规则号是您希望跳转到的位置。 下面给出了一些未加注释的例子来说明如何编写这样的规则, 用以帮助您理解包处理规则集的处理顺序。 处理流程从规则文件最上边的第一个规则开始处理, 并自顶向下地尝试每一个规则, 直到找到匹配的规则, 且数据包从防火墙中放出为止。 请注意规则号 100 101, 450, 500, 以及 510 的位置非常重要。 这些规则控制发出和接收的包的地址转换过程, 这样它们在 keep-state 动态表中的对应项中就能够与内网的 LAN IP 地址关联。 另一个需要注意的是, 所有的 allow 和 deny 规则都指定了包的方向 (也就是 outbound 或 inbound) 以及网络接口。 最后, 请注意所有发出的会话请求都会请求 skipto rule 500 以完成网络地址转换。 下面以 LAN 用户使用 web 浏览器访问一个 web 页面为例。 Web 页面使用 80 来完成通讯。 当包进入防火墙时, 规则 100 并不匹配, 因为它是发出而不是收到的包。 它能够通过规则 101, 因为这是第一个包, 因而它还没有进入动态状态保持表。 包最终到达规则 125, 并匹配该规则。 最终, 它会通过接入 Internet 公网的网卡发出。 这之前, 包的源地址仍然是内网 IP 地址。 一旦匹配这个规则, 就会触发两个动作。 keep-state 选项会把这个规则发到 keep-state 动态规则表中, 并执行所指定的动作。 动作是发到规则表中的信息的一部分。 在这个例子中, 这个动作是 "skipto rule 500"。 规则 500 NAT 包的 IP 地址, 并将其发出。 请务必牢记, 这一步非常重要。 接下来, 数据包将到达目的地, 之后返回并从规则集的第一条规则开始处理。 这一次, 它将与规则 100 匹配, 其目的 IP 地址将被映射回对应的内网 LAN IP 地址。 其后, 它会被 check-state 规则处理, 进而在暨存会话表中找到对应项, 并发到 LAN。 数据包接下来发到了内网 LAN PC 上, 而后者则会发送从远程服务器请求下一段数据的新数据包。 这个包会再次由 check-state 规则检查, 并找到发出的表项, 并执行其关联的动作, 即 'skipto 500'。 包跳转到规则 500 并被 NAT 后发出。 在接收一侧, 已经存在的会话的数据包, 会被 check-state 规则自动地处理, 并放到转发 natd 规则。 我们需要解决的问题是, 阻止所有的坏数据包, 而只允许授权的服务。 例如在防火墙上运行了 Apache 服务, 而我们希望人们在访问 Internet 公网的同时, 也能够访问本地的 web 站点。 新的接入开始请求包将匹配规则 100, 而 IP 地址则为防火墙所在的服务器而映射到了 LAN IP。 此后, 包会匹配所有我们希望检查的那些令人生厌的东西, 并最终匹配规则 425。 一旦发生匹配, 会发生两件事。 数据包会被发到 keep-state 动态表, 但此时, 所有来自那个源 IP 的会话请求的数量会被限制为 2。 这一做法能够挫败针对指定端口上服务的 DoS 攻击。 动作同时指定了包应被发到 LAN 上。 包返回时, check-state 规则会识别出包属于某一已经存在的会话交互, 并直接把它发到规则 500 做 NAT, 并发到发出接口。 示范规则集 #1: #!/bin/sh cmd="ipfw -q add" skip="skipto 500" pif=rl0 ks="keep-state" good_tcpo="22,25,37,43,53,80,443,110,119" ipfw -q -f flush $cmd 002 allow all from any to any via xl0 # exclude LAN traffic $cmd 003 allow all from any to any via lo0 # exclude loopback traffic $cmd 100 divert natd ip from any to any in via $pif $cmd 101 check-state # Authorized outbound packets $cmd 120 $skip udp from any to xx.168.240.2 53 out via $pif $ks $cmd 121 $skip udp from any to xx.168.240.5 53 out via $pif $ks $cmd 125 $skip tcp from any to any $good_tcpo out via $pif setup $ks $cmd 130 $skip icmp from any to any out via $pif $ks $cmd 135 $skip udp from any to any 123 out via $pif $ks # Deny all inbound traffic from non-routable reserved address spaces $cmd 300 deny all from 192.168.0.0/16 to any in via $pif #RFC 1918 private IP $cmd 301 deny all from 172.16.0.0/12 to any in via $pif #RFC 1918 private IP $cmd 302 deny all from 10.0.0.0/8 to any in via $pif #RFC 1918 private IP $cmd 303 deny all from 127.0.0.0/8 to any in via $pif #loopback $cmd 304 deny all from 0.0.0.0/8 to any in via $pif #loopback $cmd 305 deny all from 169.254.0.0/16 to any in via $pif #DHCP auto-config $cmd 306 deny all from 192.0.2.0/24 to any in via $pif #reserved for docs $cmd 307 deny all from 204.152.64.0/23 to any in via $pif #Sun cluster $cmd 308 deny all from 224.0.0.0/3 to any in via $pif #Class D & E multicast # Authorized inbound packets $cmd 400 allow udp from xx.70.207.54 to any 68 in $ks $cmd 420 allow tcp from any to me 80 in via $pif setup limit src-addr 1 $cmd 450 deny log ip from any to any # This is skipto location for outbound stateful rules $cmd 500 divert natd ip from any to any out via $pif $cmd 510 allow ip from any to any ######################## end of rules ################## 下面的这个规则集基本上和上面一样, 但使用了易于读懂的编写方式, 并给出了相当多的注解, 以帮助经验较少的 IPFW 规则编写者更好地理解这些规则到底在做什么。 示范规则集 #2: #!/bin/sh ################ Start of IPFW rules file ############################### # Flush out the list before we begin. ipfw -q -f flush # Set rules command prefix cmd="ipfw -q add" skip="skipto 800" pif="rl0" # public interface name of NIC # facing the public Internet ################################################################# # No restrictions on Inside LAN Interface for private network # Change xl0 to your LAN NIC interface name ################################################################# $cmd 005 allow all from any to any via xl0 ################################################################# # No restrictions on Loopback Interface ################################################################# $cmd 010 allow all from any to any via lo0 ################################################################# # check if packet is inbound and nat address if it is ################################################################# $cmd 014 divert natd ip from any to any in via $pif ################################################################# # Allow the packet through if it has previous been added to the # the "dynamic" rules table by a allow keep-state statement. ################################################################# $cmd 015 check-state ################################################################# # Interface facing Public Internet (Outbound Section) # Interrogate session start requests originating from behind the # firewall on the private network or from this gateway server # destine for the public Internet. ################################################################# # Allow out access to my ISP's Domain name server. # x.x.x.x must be the IP address of your ISP's DNS # Dup these lines if your ISP has more than one DNS server # Get the IP addresses from /etc/resolv.conf file $cmd 020 $skip tcp from any to x.x.x.x 53 out via $pif setup keep-state # Allow out access to my ISP's DHCP server for cable/DSL configurations. $cmd 030 $skip udp from any to x.x.x.x 67 out via $pif keep-state # Allow out non-secure standard www function $cmd 040 $skip tcp from any to any 80 out via $pif setup keep-state # Allow out secure www function https over TLS SSL $cmd 050 $skip tcp from any to any 443 out via $pif setup keep-state # Allow out send & get email function $cmd 060 $skip tcp from any to any 25 out via $pif setup keep-state $cmd 061 $skip tcp from any to any 110 out via $pif setup keep-state # Allow out FreeBSD (make install & CVSUP) functions # Basically give user root "GOD" privileges. $cmd 070 $skip tcp from me to any out via $pif setup keep-state uid root # Allow out ping $cmd 080 $skip icmp from any to any out via $pif keep-state # Allow out Time $cmd 090 $skip tcp from any to any 37 out via $pif setup keep-state # Allow out nntp news (i.e. news groups) $cmd 100 $skip tcp from any to any 119 out via $pif setup keep-state # Allow out secure FTP, Telnet, and SCP # This function is using SSH (secure shell) $cmd 110 $skip tcp from any to any 22 out via $pif setup keep-state # Allow out whois $cmd 120 $skip tcp from any to any 43 out via $pif setup keep-state # Allow ntp time server $cmd 130 $skip udp from any to any 123 out via $pif keep-state ################################################################# # Interface facing Public Internet (Inbound Section) # Interrogate packets originating from the public Internet # destine for this gateway server or the private network. ################################################################# # Deny all inbound traffic from non-routable reserved address spaces $cmd 300 deny all from 192.168.0.0/16 to any in via $pif #RFC 1918 private IP $cmd 301 deny all from 172.16.0.0/12 to any in via $pif #RFC 1918 private IP $cmd 302 deny all from 10.0.0.0/8 to any in via $pif #RFC 1918 private IP $cmd 303 deny all from 127.0.0.0/8 to any in via $pif #loopback $cmd 304 deny all from 0.0.0.0/8 to any in via $pif #loopback $cmd 305 deny all from 169.254.0.0/16 to any in via $pif #DHCP auto-config $cmd 306 deny all from 192.0.2.0/24 to any in via $pif #reserved for docs $cmd 307 deny all from 204.152.64.0/23 to any in via $pif #Sun cluster $cmd 308 deny all from 224.0.0.0/3 to any in via $pif #Class D & E multicast # Deny ident $cmd 315 deny tcp from any to any 113 in via $pif # Deny all Netbios service. 137=name, 138=datagram, 139=session # Netbios is MS/Windows sharing services. # Block MS/Windows hosts2 name server requests 81 $cmd 320 deny tcp from any to any 137 in via $pif $cmd 321 deny tcp from any to any 138 in via $pif $cmd 322 deny tcp from any to any 139 in via $pif $cmd 323 deny tcp from any to any 81 in via $pif # Deny any late arriving packets $cmd 330 deny all from any to any frag in via $pif # Deny ACK packets that did not match the dynamic rule table $cmd 332 deny tcp from any to any established in via $pif # Allow traffic in from ISP's DHCP server. This rule must contain # the IP address of your ISP's DHCP server as it's the only # authorized source to send this packet type. # Only necessary for cable or DSL configurations. # This rule is not needed for 'user ppp' type connection to # the public Internet. This is the same IP address you captured # and used in the outbound section. $cmd 360 allow udp from x.x.x.x to any 68 in via $pif keep-state # Allow in standard www function because I have Apache server $cmd 370 allow tcp from any to me 80 in via $pif setup limit src-addr 2 # Allow in secure FTP, Telnet, and SCP from public Internet $cmd 380 allow tcp from any to me 22 in via $pif setup limit src-addr 2 # Allow in non-secure Telnet session from public Internet # labeled non-secure because ID & PW are passed over public # Internet as clear text. # Delete this sample group if you do not have telnet server enabled. $cmd 390 allow tcp from any to me 23 in via $pif setup limit src-addr 2 # Reject & Log all unauthorized incoming connections from the public Internet $cmd 400 deny log all from any to any in via $pif # Reject & Log all unauthorized out going connections to the public Internet $cmd 450 deny log all from any to any out via $pif # This is skipto location for outbound stateful rules $cmd 800 divert natd ip from any to any out via $pif $cmd 801 allow ip from any to any # Everything else is denied by default # deny and log all packets that fell through to see what they are $cmd 999 deny log all from any to any ################ End of IPFW rules file ############################### diff --git a/zh_CN.GB2312/books/handbook/geom/chapter.sgml b/zh_CN.GB2312/books/handbook/geom/chapter.sgml index 798098198c..deeb48f497 100644 --- a/zh_CN.GB2312/books/handbook/geom/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/geom/chapter.sgml @@ -1,616 +1,704 @@ Tom Rhodes 原作 GEOM: 模块化磁盘变换框架 概述 GEOM GEOM 磁盘框架 GEOM 本章将介绍以 &os; GEOM 框架来使用磁盘。 这包括了使用这一框架来配置的主要的 RAID 控制工具。 这一章不会深入讨论 GEOM 如何处理或控制 I/O、 其下层的子系统或代码。 您可以从 &man.geom.4; 联机手册及其众多 SEE ALSO 参考文献中得到这些信息。 这一章也不是对 RAID 配置的权威介绍, 它只介绍由 支持GEOM 的 RAID 级别。 读完这章, 您将了解: 通过 GEOM 支持的 RAID 类型。 如何使用基本工具来配置和管理不同的 RAID 级别。 如何通过 GEOM 使用镜像、 条带、 加密和挂接在远程的磁盘设备。 如何排除挂接在 GEOM 框架上的磁盘设备的问题。 阅读这章之前, 您应: 理解 &os; 如何处理磁盘设备 ()。 了解如何配置和安装新的 &os; 内核 ()。 GEOM 介绍 GEOM 允许访问和控制类 (classes) — 主引导记录、 BSD 标签 (label), 等等 — 通过使用 provider, 或在 /dev 中的特殊文件。 它支持许多软件 RAID 配置, GEOM 能够向操作系统, 以及在其上运行的工具提供透明的访问方式。 Tom Rhodes 原作 Murray Stokely RAID0 - 条带 GEOM 条带 条带是一种将多个磁盘驱动器合并为一个卷的方法。 许多情况下, 这是通过硬件控制器来完成的。 GEOM 磁盘子系统提供了 RAID0 的软件支持, 它也成为磁盘条带。 RAID0 系统中, 数据被分为多个块, 这些块将分别写入阵列的所有磁盘。 与先前需要等待系统将 256k 数据写到一块磁盘上不同, RAID0 系统, 能够同时分别将打碎的 64k 写到四块磁盘上, 从而提供更好的 I/O 性能。 这一性能提升还能够通过使用多个磁盘控制器来进一步改进。 RAID0 条带中的每一个盘的尺寸必须一样, 因为 I/O 请求是分散到多个盘上的, 以便让这些盘上的读写并行完成。 磁盘条带图 在未格式化的 ATA 磁盘上建立条带 - 加载 geom_stripe + 加载 geom_stripe.ko 模块: &prompt.root; kldload geom_stripe 确信存在合适的挂接点 (mount point)。 如果这个卷将成为根分区, 那么暂时把它挂接到其他位置i, 如 /mnt &prompt.root; mkdir /mnt 确定将被做成条带卷的磁盘的设备名, 并创建新的条带设备。 举例而言, 要将两个未用的、 尚未分区的 ATA 磁盘 /dev/ad2/dev/ad3 做成一个条带设备: - &prompt.root; gstripe label -v st0 /dev/ad2 /dev/ad3 + &prompt.root; gstripe label -v st0 /dev/ad2 /dev/ad3 +Metadata value stored on /dev/ad2. +Metadata value stored on /dev/ad3. +Done. - 接着需要写标准的 label, 也就是通常所说的分区表到新卷上, 并安装标准的引导代码: &prompt.root; bsdlabel -wB /dev/stripe/st0 上述过程将在 /dev/stripe 目录中的 st0 设备基础上建立两个新设备。 这包括 st0ast0c。 这时, 就可以在 st0a 设备上用下述 newfs 命令来建立文件系统了: &prompt.root; newfs -U /dev/stripe/st0a 在屏幕上将滚过一些数字, 整个操作应该能在数秒内完成。 现在可以挂接刚刚做好的卷了。 要挂接刚创建的条带盘: &prompt.root; mount /dev/stripe/st0a /mnt 要在启动过程中自动挂接这个条带上的文件系统, 需要把关于卷的信息放到 - /etc/fstab 文件中: + /etc/fstab 文件中。为达到此目的, + 需要创建一个叫 stripe + 永久的挂载点: - &prompt.root; echo "/dev/stripe/st0a /mnt ufs rw 2 2" \ + &prompt.root; mkdir /stripe +&prompt.root; echo "/dev/stripe/st0a /stripe ufs rw 2 2" \ >> /etc/fstab - 此外, geom_stripe 模块也必须通过在 + 此外, geom_stripe.ko 模块也必须通过在 /boot/loader.conf 中增加下述设置, 以便在系统初始化过程中自动加载。 &prompt.root; echo 'geom_stripe_load="YES"' >> /boot/loader.conf RAID1 - 镜像 GEOM 磁盘镜像 镜像是许多公司和家庭用户使用的一种无须中断的备份技术。 简单地说, 镜像的概念就是 磁盘B 是同步复制 (replicate) 的 磁盘A 的副本, 或者 磁盘C+D 是 diskA+B 的同步复制副本, 等等。 无论磁盘配置如何, 这种技术的共同特点都是一块磁盘或分区的内容会同步复制到另外的地方。 这样, 除了能够很容易地恢复信息之外, 还能够在无须中断服务或访问的情况下进行备份, 甚至直接将副本送到数据保安公司异地储存。 在开始做这件事之前, 首先请准备两个容量相同的磁盘驱动器, 下面的例子假定它们都是使用直接访问方式 (Direct Access, &man.da.4;) 的 SCSI 磁盘。 对主磁盘进行镜像 假定您现有系统中的 &os; 安装到了第一个, 也就是 da0 盘上, 则应告诉 &man.gmirror.8; 将主要数据保存在这里。 在开始构建镜像卷之前, 可以启用更多的调试信息, 并应开放对设备的完全访问。 这可以通过将 &man.sysctl.8; 变量 kern.geom.debugflags 设置为下面的值来实现: &prompt.root; sysctl kern.geom.debugflags=17 接下来需要创建镜像。 这个过程的第一步是在主磁盘上保存元数据信息, 也就是用下面的命令来创建 /dev/mirror/gm 设备: + + 如果有数据被存放在磁盘最后的扇区, + 并在启动设备上创建镜像的话可能导致数据丢失。 + 在新安装 &os; 之后立即创建镜像可以减低此风险。 + + &prompt.root; gmirror label -vb round-robin gm0 /dev/da0 系统应给出下面的回应: Metadata value stored on /dev/da0. Done. 初始化 GEOM, 这步操作会加载内核模块 /boot/kernel/geom_mirror.ko &prompt.root; gmirror load 当这个命令运行完之后, 系统会在 /dev/mirror 目录中创建设备节点 gm0 配置在系统初始化过程中自动加载 geom_mirror.ko &prompt.root; echo 'geom_mirror_load="YES"' >> /boot/loader.conf 编辑 /etc/fstab 文件, 将其中先前的 da0 改为新的镜像设备 - gm0。 以 root 用户身份编辑 - /etc/fstab + gm0。 + + + 如果 &man.vi.1; 是你喜欢的编辑器, + 以下则是完成此项任务的一个简便方法: - &prompt.root; vi /etc/fstab + &prompt.root; vi /etc/fstab - 在 &man.vi.1; 中备份现有的 - fstab 内容, 具体操作是 - :w /etc/fstab.bak。 接着, - 把所有旧的 da0 替换成 gm0, - 也就是输入命令 - :%s/da/mirror\/gm/g + 在 &man.vi.1; 中备份现有的 + fstab 内容, 具体操作是 + :w /etc/fstab.bak。 接着, + 把所有旧的 da0 替换成 gm0, + 也就是输入命令 + :%s/da/mirror\/gm/g + 修改完后的 fstab 文件应该是下面的样子。 磁盘驱动器是 SCSIATA 甚至 RAID 都没有关系, 最终的结果都是 gm # Device Mountpoint FStype Options Dump Pass# -/dev/mirror/gm0s2b none swap sw 0 0 -/dev/mirror/gm0s2a / ufs rw 1 1 -#/dev/mirror/gm0s2d /store ufs rw 2 2 -/dev/mirror/gm0s2e /usr ufs rw 2 2 +/dev/mirror/gm0s1b none swap sw 0 0 +/dev/mirror/gm0s1a / ufs rw 1 1 +/dev/mirror/gm0s1d /usr ufs rw 0 0 +/dev/mirror/gm0s1f /home ufs rw 2 2 +#/dev/mirror/gm0s2d /store ufs rw 2 2 +/dev/mirror/gm0s1e /var ufs rw 2 2 /dev/acd0 /cdrom cd9660 ro,noauto 0 0 重启系统: &prompt.root; shutdown -r now 在系统初始化过程中, 新建的 gm0 会代替 da0 设备工作。 系统完成初始化之后, 可以通过检查 mount 命令的输出来查看效果: &prompt.root; mount Filesystem 1K-blocks Used Avail Capacity Mounted on /dev/mirror/gm0s1a 1012974 224604 707334 24% / devfs 1 1 0 100% /dev /dev/mirror/gm0s1f 45970182 28596 42263972 0% /home /dev/mirror/gm0s1d 6090094 1348356 4254532 24% /usr /dev/mirror/gm0s1e 3045006 2241420 559986 80% /var devfs 1 1 0 100% /var/named/dev 这个输出是正常的。 最后, 使用下面的命令将 da1 磁盘加到镜像卷中, 以开始同步过程: &prompt.root; gmirror insert gm0 /dev/da1 在构建镜像卷的过程中, 可以用下面的命令查看状态: &prompt.root; gmirror status 一旦镜像卷的构建操作完成, 这个命令的输出就会变成这样: Name Status Components mirror/gm0 COMPLETE da0 da1 如果有问题或者构建仍在进行, 输出中的 COMPLETE 就会是 DEGRADED 故障排除 系统拒绝引导 如果系统引导时出现类似下面的提示: ffs_mountroot: can't find rootvp Root mount failed: 6 mountroot> 这种情况应使用电源或复位按钮重启机器。 在引导菜单中, 选择第六 (6) 个选项。 这将让系统进入 &man.loader.8; 提示符。 在此处手工加载内核模块: OK? load geom_mirror OK? boot 如果这样做能解决问题, 则说明由于某种原因模块没有被正确加载。 - 可以通过在内核配置文件中加入: + 检查 /boot/loader.conf 中相关条目是否正确。 + 如果问题仍然存在,可以在内核配置文件中加入: options GEOM_MIRROR 然后重新编译和安装内核来解决这个问题。 从磁盘故障中恢复 磁盘镜像的一大好处是在当其中一个磁盘出现故障时, 可以很容易地将其替换掉, 并且通常不会丢失数据。 考虑前面的 RAID1 配置, 假设 da1 出现了故障并需要替换, 要替换它, 首先确定哪个磁盘出现了故障, 并关闭系统。 此时, 可以用换上新的磁盘, 并重新启动系统。 这之后可以用下面的命令来完成磁盘的替换操作: &prompt.root; gmirror forget gm0 &prompt.root; gmirror insert gm0 /dev/da1 在重建过程中可以用 gmirror 命令来监看进度。 就是这样简单。 GEOM Gate 网络设备 通过 gate 工具, GEOM 支持以远程方式使用设备, 例如磁盘、 CD-ROM、 文件等等。 这和 NFS 类似。 在开始工作之前, 首先要创建一个导出文件。 这个文件的作用是指定谁可以访问导出的资源, 以及提供何种级别的访问授权。 例如, 要把第一块 SCSI 盘的第四个 slice 导出, 对应的 /etc/gg.exports 会是类似下面的样子: 192.168.1.0/24 RW /dev/da0s4d 这表示允许同属私有子网的所有机器访问 da0s4d 分区上的文件系统。 要导出这个设备, 首先请确认它没有被挂接, 然后是启动 &man.ggated.8; 服务: &prompt.root; ggated 现在我们将在客户机上 mount 该设备, 使用下面的命令: &prompt.root; ggatec create -o rw 192.168.1.1 /dev/da0s4d ggate0 &prompt.root; mount /dev/ggate0 /mnt 到此为止, 设备应该已经可以通过挂接点 /mnt 访问了。 请注意, 如果设备已经被服务器或网络上的任何其他机器挂接, 则前述操作将会失败。 如果不再需要使用这个设备, 就可以使用 &man.umount.8; 命令来安全地将其卸下了, 这一点和其他磁盘设备类似。 为磁盘设备添加卷标 GEOM 磁盘卷标 在系统初始化的过程中, &os; 内核会为检测到的设备创建设备节点。 这种检测方式存在一些问题, 例如, 在通过 USB 添加设备时应如何处理? 很可能有闪存盘设备最初被识别为 da0 而在这之后, 则由 da0 变成了 da1。 而这则会在挂接 /etc/fstab 中的文件系统时造成问题, 这些问题, 还可能在系统引导时导致无法正常启动。 解决这个问题的一个方法是以连接拓扑方式链式地进行 SCSI 设备命名, 这样, 当在 SCSI 卡上增加新设备时, 这些设备将使用一个未用的编号。 但如果 USB 设备取代了主 SCSI 磁盘的位置呢? 由于 USB 通常会在 SCSI 卡之前检测到, 因此很可能出现这种现象。 当然, 可以通过在系统引导之后再插入这些设备来绕过这个问题。 另一种绕过这个问题的方法, 则是只使用 ATA 驱动器, 并避免在 /etc/fstab 中列出 SCSI 设备。 还有一种更好的解决方法。 通过使用 glabel 工具, 管理员或用户可以为磁盘设备打上标签, 并在 /etc/fstab 中使用这些标签。 由于 glabel 会将标签保存在对应 provider 的最后一个扇区, 在系统重启之后, 它仍会持续存在。 因此, 通过将具体的设备替换为使用标签表示, 无论设备节点变成什么, 文件系统都能够顺利地完成挂接。 这并不是说标签一定是永久性的。 glabel 工具既可以创建永久性标签, 也可以创建临时性标签。 在重启时, 只有永久性标签会保持。 请参见联机手册 &man.glabel.8; 以了解两者之间的差异。 标签类型和使用示范 有两种类型的标签, 一种是普通标签, 另一种是文件系统标签。 - 两者的差异体现在是否能够自动检测, 以及是否在重启后保持。 这些标签会放到 - /dev 中的特殊目录中, - 这些目录的名字取决于文件系统类型。 例如, + 标签可以是永久性的或暂时性的。永久性的标签可以通过 + &man.tunefs.8; 或 &man.newfs.8; 命令创键。根据文件系统的类型, + 它们将在 /dev + 下的一个子目录中被创建。例如, UFS2 文件系统的标签会创建到 /dev/ufs - 目录中。 + 目录中。永久性的标签还可以使用 glabel label + 创建。它们不再是文件系统特定的,而是会在 + /dev/label + 目录中被创建。 - 普通标签在系统下次重启时会消失, 这些标签会创建到 + 暂时性的标签在系统下次重启时会消失, 这些标签会创建到 /dev/label 目录中, - 很适合测试之用。 + 很适合测试之用。可以使用 glabel create + 创建暂时性的标签。请参阅 &man.glabel.8; + 手册页以获取更多详细信息。 - 永久性标签可以使用 - tunefsnewfs - 工具来创建。 要为 - UFS2 文件系统创建标签, 而不破坏其上的数据, - 可以使用下面的命令: + 要为一个 UFS2 文件系统创建永久性标签, + 而不破坏其上的数据,可以使用下面的命令: &prompt.root; tunefs -L home /dev/da3 如果文件系统满了, 这可能会导致数据损坏; 不过, 如果文件系统快满了, 此时应首先删除一些无用的文件, 而不是增加标签。 现在, 您应可以在 /dev/ufs 目录中看到标签, 并将其加入 /etc/fstab /dev/ufs/home /home ufs rw 2 2 当运行 tunefs 时, 应首先卸下文件系统。 现在可以像平时一样挂接文件系统了: &prompt.root; mount /home 现在, 只要在系统引导时通过 /boot/loader.conf 配置加载了内核模块 geom_label.ko, 或在联编内核时指定了 GEOM_LABEL 选项, 设备节点由于增删设备而顺序发生变化时, 就不会影响文件系统的挂接了。 通过使用 newfs 命令的 参数, 可以在创建文件系统时为其添加默认的标签。 请参见联机手册 &man.newfs.8; 以了解进一步的详情。 下列命令可以清除标签: &prompt.root; glabel destroy home + + 以下的例子展示了如何为一个启动磁盘打上标签。 + + + 为启动磁盘打上标签 + + 为启动磁盘打上永久性标签, 系统应该能够正常启动, + 即使磁盘被移动到了另外一个控制器或者转移到了一个不同的系统上。 + 此例中我们假设使用了一个 ATA 磁盘, + 当前这个设备被系统识别为 ad0。 + 还假设使用了标准的 &os; 分区划分方案, + /, + /var, + /usr 和 + /tmp 文件系统, + 还有一个 swap 分区。 + + 重启系统,在 &man.loader.8; 提示符下键入 + 4 启动到单用户模式。 + 然后输入以下的命令: + + &prompt.root; glabel label rootfs /dev/ad0s1a +GEOM_LABEL: Label for provider /dev/ad0s1a is label/rootfs +&prompt.root; glabel label var /dev/ad0s1d +GEOM_LABEL: Label for provider /dev/ad0s1d is label/var +&prompt.root; glabel label usr /dev/ad0s1f +GEOM_LABEL: Label for provider /dev/ad0s1f is label/usr +&prompt.root; glabel label tmp /dev/ad0s1e +GEOM_LABEL: Label for provider /dev/ad0s1e is label/tmp +&prompt.root; glabel label swap /dev/ad0s1b +GEOM_LABEL: Label for provider /dev/ad0s1b is label/swap +&prompt.root; exit + + 系统加继续启动进入多用户模式。 在启动完毕后, 编辑 + /etc/fstab 用各自的标签替换下常规的设备名。 + 最终 /etc/fstab 看起来差不多是这样的: + + # Device Mountpoint FStype Options Dump Pass# +/dev/label/swap none swap sw 0 0 +/dev/label/rootfs / ufs rw 1 1 +/dev/label/tmp /tmp ufs rw 2 2 +/dev/label/usr /usr ufs rw 2 2 +/dev/label/var /var ufs rw 2 2 + + 现在可以重启系统了。 如果一切顺利的话, + 系统可以正常启动并且 mount 命令显示: + + &prompt.root; mount +/dev/label/rootfs on / (ufs, local) +devfs on /dev (devfs, local) +/dev/label/tmp on /tmp (ufs, local, soft-updates) +/dev/label/usr on /usr (ufs, local, soft-updates) +/dev/label/var on /var (ufs, local, soft-updates) + 通过 GEOM 实现 UFS 日志 GEOM 日志 随着 &os; 7.0 的发布, 实现了长期为人们所期待的 UFS 日志。 这个实现采用了 GEOM 子系统, 可以很容易地使用 &man.gjournal.8; 工具来进行配置。 日志是什么? 日志的作用是保存文件系统事务的记录, 换言之, 完成一次完整的磁盘写入操作所需的变动, 这些记录会在元数据以及文件数据写盘之前, 写入到磁盘中。 这种事务日志可以在随后用于重放并完成文件系统事务, 以避免文件系统出现不一致的问题。 这种方法是另一种阻止文件系统丢失数据并发生不一致的方法。 与 Soft Updates - 追踪并确保元数据更新顺序这种方法不同, 它会实际地将日志保存到磁盘最后的扇区, - 或另外一块磁盘上。 + 追踪并确保元数据更新顺序这种方法不同, + 它会实际地将日志保存到指定为此项任务保留的磁盘空间上, + 在某些情况下可全部存放到另外一块磁盘上。 与其他文件系统的日志实现不同, gjournal 采用的是基于块, 而不是作为文件系统的一部分的方式 - 它只是作为一种 GEOM 扩展实现。 如果希望启用 gjournal, &os; 内核需要下列选项 - 这是 7.X 系统上的默认配置: options UFS_GJOURNAL + 如果使用日志的卷需要在启动的时候被挂载, 还需加载 + geom_journal.ko 内核模块, + 将以下着行加入 /boot/loader.conf + + geom_journal_load="YES" + + 这个功能也可被编译进一个定制的内核, + 需在内核配置文件中加入以下这行: + + options GEOM_JOURNAL + 现在, 可以为空闲的文件系统创建日志了。 对于新增的 SCSI 磁盘 da4, 具体的操作步骤为: &prompt.root; gjournal label /dev/da4 &prompt.root; gjournal load 这样, 就会出现一个与 /dev/da4 设备节点对应的 /dev/da4.journal 设备节点。 接下来, 可以在这个设备上建立文件系统: &prompt.root; newfs -O 2 -J /dev/da4.journal 这个命令将建立一个包含日志的 UFS2 文件系统。 然后就可以用 mount 命令来挂接设备了: &prompt.root; mount /dev/da4.journal /mnt 当磁盘包含多个 slice 时, 每个 slice 上都会建立日志。 例如, 如果有 ad4s1ad4s2 这两个 slice, 则 gjournal 会建立 ad4s1.journalad4s2.journal。 如果连续运行两次这个命令, 则会建立 多层日志 在某些情况下, 可能会希望在其他磁盘上保存日志。 对于这些情形, 日志提供者或存储设备, 应在启用日志的设备后给出。 在暨存的文件系统上, 可以用 tunefs 来启用日志; 不过, 在尝试修改文件系统之前, 您应对其进行备份。 多数情况下, gjournal 会因为无法建立日志而失败, 在误用 tunefs 时, 这可能导致失败。 + + 对于 &os; 系统的启动磁盘使用日志也是可能的。 + 请参阅 Implementing UFS Journaling on + a Desktop PC 以获得更多详细信息。 diff --git a/zh_CN.GB2312/books/handbook/install/chapter.sgml b/zh_CN.GB2312/books/handbook/install/chapter.sgml index fd18eaed6d..0817ce6af2 100644 --- a/zh_CN.GB2312/books/handbook/install/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/install/chapter.sgml @@ -1,4471 +1,4491 @@ Jim Mock 结构、组织重整, 部分重写 Randy Pratt sysinstall 操作流程、屏幕抓图以及一般性文件 安装 FreeBSD 概述 installation FreeBSD 提供了一个以文字为主,简单好用的安装程序,叫做 sysinstall 。这是 FreeBSD 默认使用的安装程序; 厂商如果想,也可以提供适合自己需要的安装程序。本章说明如何使用 sysinstall 来安装 FreeBSD。 学习完本章之后,您将会知道: 如何制作 FreeBSD 安装磁盘 FreeBSD如何参照及分割您的硬盘 如何启动 sysinstall. 在执行 sysinstall 时您将要回答的问题、 问题代表什么意义,以及该如何回答它们。 在阅读本章之前,您应该: 阅读您要安装的 FreeBSD 版本所附的硬件支持列表以确定您的硬件有没有被支持。 一般来说,此安装说明是针对 &i386; (PC 兼容机) 体系结构的电脑。如果有其它体系结构(如Alpha)的安装说明, 我们将一并列出。虽然本文档经常保持更新, 但有可能与您安装版本上所带的说明文档有些许出入。 在这里建议您使用本说明文章作为一般性的安装指导参考手册。 硬件需求 最小配置 安装 &os; 所需的最小硬件配置, 随 &os; 版本和硬件架构不同而有所不同。 关于安装所需的最低硬件配置信息, 可以在 &os; 网站的 发行版信息 部分中的 安装说明书 中找到。在接下来的几节中, 给出了这些信息的一些总结。随您安装 &os; 的方式不同, 可能需要使用软驱或为 &os; 支持的 CDROM 驱动器, 有时候也可能需要的是一块网卡。 这将在 中进行介绍。 &os;/&arch.i386; 和 &os;/&arch.pc98; &os;/&arch.i386; 和 &os;/&arch.pc98; 版本, 都需要 486 或更高的处理器,以及至少 24 MB 的 RAM。 您需要至少 150 MB 的空闲硬盘空间, 才能完成最小的安装配置。 对于老旧的硬件而言, 多数时候, 装配更多的 RAM 和腾出更多的硬盘空间, 要比使用更快的处理器更有用。 &os;/&arch.alpha; Alpha 要安装 &os;/&arch.alpha;, 您使用的必须是某种受支持的平台 (参见 ) 而且 &os; 必须独占一个硬盘。目前 &os; 还无法与其它操作系统共享磁盘。 这个磁盘必须接在 SRM 固件支持的 SCSI 控制器上,或者如果您机器上的 SRM 支持从 IDE 硬盘启动,则应装到 IDE 硬盘上。 ARC Alpha BIOS SRM 此外您还需要用于您的平台 SRM 控制台固件。有时,可以在 AlphaBIOS (或 ARC) 固件和 SRM 之间切换。如果没有, 则需要从制造商网站上下载并安装新的固件。 对于 Alpha 的支持, 从 &os; 7.0 版本开始已经不再提供。 &os; 6.X 系列发行版, 是最后一批支持这种硬件平台的版本。 &os;/&arch.amd64; 有两类处理器同时能够支持运行 &os;/&arch.amd64;。 第一种是 AMD64 处理器, 包括 &amd.athlon;64、 &amd.athlon;64-FX、 &amd.opteron; 以及更高级别的处理器。 能够使用 &os;/&arch.amd64; 的另一种处理器是包含了采用 &intel; EM64T 架构支持的处理器。 这类处理器包括 &intel; &core; 2 Duo、 Quad、 以及 Extreme 系列处理器, 以及 &intel; &xeon; 3000、 5000、 和 7000 系列处理器。 如果您的计算机使用 nVidia nForce3 Pro-150, 则 必须 使用 BIOS 配置, 禁用 IO APIC。 如果您没有找到这样的选项, 可能就只能转而禁用 ACPI 了。 Pro-150 芯片组存在一个 bug, 目前我们还没有找到绕过这一问题的方法。 &os;/&arch.sparc64; 要安装 &os;/&arch.sparc64;, 必须使用它支持的平台 (参见 )。 &os;/&arch.sparc64; 需要独占一块磁盘。 目前还没有办法与其它操作系统共享一块磁盘。 支持的硬件 支持的硬件列表, 会作为 &os; 发行版本的 &os; 兼容硬件说明提供。 这个文档通常可以在 CDROM 或 FTP 安装文件的顶级目录找到, 它的名字是 HARDWARE.TXT, 此外, 在 sysinstall 的 documentation 菜单也可以找到。它针对特定的硬件架构列出了 &os; 已知支持的硬件。 不同发行版本和架构上的硬件支持列表,可以在 &os; 网站的 发行版信息 页面上找到。 安装前的准备工作 列出您电脑的硬件清单 在安装 FreeBSD 之前,您应该试着将您电脑中的硬件清单列出来。 FreeBSD 安装程序会将这些硬件(磁盘、网卡、光驱等等) 以及型号及制造厂商列出来。FreeBSD 也会尝试为这些设备找出最适当的 IRQ 及 IO 端口的设定。但是因为 PC 的硬件种类实在太过复杂, 这个步骤不一定总是能成功。这时, 您就可能需要手动更改有问题的设备的设定值。 如果您已经安装了其它的操作系统,如 &windows; 或 Linux, 那么您可以先由这些系统所提供的工具来查看您的设备设定值是怎么分配的。 如果您真的没办法确定某些接口卡用什么设定值,那么您可以检查看看, 说不定它的设定已经标示在卡上。常用的 IRQ 号码为 3、5 以及 7; IO 端口的值通常以 16 进制位表示,例如 Ox330。 我们建议您在安装 FreeBSD 之前把这些信息打印或记录下来,做成表格 的样子也许会比较有帮助,例如: 硬件设备清单 设备名 IRQ IO 端口号 备注 第一块硬盘 N/A N/A 40 GB,Seagate 制造,第一个 IDE 接口主设备 CDROM N/A N/A 第一个 IDE 接口从设备 第二块硬盘 N/A N/A 20 GB,IBM 制造, 第二个 IDE 接口主设备 第一个 IDE 控制器 14 0x1f0 网卡 N/A N/A &intel; 10/100 Modem N/A N/A &tm.3com; 56K faxmodem,位于 COM1 口
在清楚地了解了您计算机的配置之后, 需要检查它是否符合您希望安装的 &os; 版本的硬件需求。
备份您的数据 如果您的电脑上面存有重要的数据资料, 那么在安装 FreeBSD 前请确定您已经将这些资料备份了, 并且先测试这些备份文档是否有问题。FreeBSD 安装程序在要写入任何资料到您的硬盘前都会先提醒您确认, 一旦您确定要写入,那么以后就没有反悔的机会。 决定要将 FreeBSD 安装到哪里 如果您想让 FreeBSD 使用整个硬盘,那么请直接跳到下一节。 但是,如果您想让 FreeBSD 跟您已有的系统并存, 那么您必须对您数据存在硬盘的分布方式有深入的了解, 以及其所造成的影响。 &os;/&arch.i386; 体系结构的硬盘分配方式 一个 PC 硬盘可以被细分为许多块。 这些块被称为 partitions (分区)。 由于 &os; 内部也有分区的概念,如此命名很容易导致混淆, 因此我们在 &os; 中,将其称为磁盘 slice,或简称为 slices。 例如, FreeBSD 提供的用于操作 PC 磁盘分区的工具 fdisk 就将其称为 slice 而不是 partition。 由于设计的原因, 每个硬盘仅支持四个分区; 这些分区叫做 主分区(Primary partion)。 为了突破这个限制以便能使用更多的分区,就有了新的分区类型,叫做 扩展分区(Extended partition)。 一个硬盘可以拥有一个扩展分区。在扩展分区里可以建立许多个所谓的 逻辑分区(Logical partitions) 每个分区都有其独立的 分区号(partition ID), 用以区分每个分区的数据类型。FreeBSD 分区的分区号为 165 一般而言,每种操作系统都会有自己独特的方式来区别分区。 例如 DOS 及其之后的 &windows;, 会分配给每个主分区及逻辑分区一个 驱动器字符, 从 C: 开始。 FreeBSD 必须安装在主分区。FreeBSD 可以在这个分区上面存放系统数据或是您建立的任何文件。 然而,如果您有多个硬盘,您也可以在这些硬盘上(全部或部分)建立 FreeBSD 分区。在您安装 FreeBSD 的时候,必须要有一个分区可以给 FreeBSD 使用。 这个分区可以是尚未规划的分区, 或是已经存在且存有数据但您不再需要的分区。 如果您已经用完了您硬盘上的所有分区, 那么您必须使用其它操作系统所提供的工具 (如 DOS 或 &windows; 下的 fdisk) 来腾出一个分区给 FreeBSD 使用。 如果您的某个分区有多余的空间,您可以使用它。 但是使用前您需要先整理一下这些分区。 FreeBSD 最小安装需要约 100 MB 的空间,但是这仅是 非常 基本的安装, 几乎没有剩下多少空间可以建立您自己的文件。一个较理想的最小安装是 250 MB,不含图形界面;或是 350 MB 以上,包含图形界面。 如果您还需要安装其它的第三方厂商的套件, 那么将需要更多的硬盘空间。 您可以使用商业软件,例如 &partitionmagic; (硬盘分区魔术师) 或类似 GParted 这样的免费工具来调整分区尺寸,为 FreeBSD 腾出空间。 FreeBSD 光盘的 tools 目录包含两个免费的工具也可以完成这个工作: FIPS 以及 PResizer,它们的文档可以在同一目录中找到。 FIPSPResizer, 和 &partitionmagic; 能够改变 FAT16 以及 FAT32 分区的大小 — 它们可以在 &ms-dos; 以及 &windows; ME 系统中使用。 这些工具的说明文件可以在同一个目录下面找到。 &partitionmagic;GParted 都能改变 NTFS 分区的尺寸。 GParted 在许多 Live CD Linux 发行版, 如 SystemRescueCD 中均有提供。 目前已经有报告显示改变 µsoft; Vista 分区尺寸时会出现问题。 在进行此类操作时, 建议您准备一张 Vista 安装 CDROM。如同其他的磁盘维护操作一样, 强烈建议您事先进行备份。 不当的使用这些工具可能会删掉您硬盘上的数据资料! 在使用这些工具前确定您有最近的、没问题的备份数据。 使用已存在的分区 假设您只有一个 4GB 的硬盘,而且已经装了 &windows; 然后您将这个硬盘分成两个分区 C:D:,每个分区大小为 2 GB。在 C: 分区上存放有 1 GB 的数据、 D:分区上存放 0.5 GB 的数据。 这意味着您的盘上有两个分区,一个驱动器符号是一个分区 (如 c:、d:)。 您可以把所有存放在 D: 分区上的数据复制到 C: 分区, 这样就空出了一个分区(d:)给 FreeBSD 使用。 缩减已现在的分区 假设您只有一个 4 GB 的硬盘,而且已经装了 &windows;。 您在安装 &windows; 的时候把 4 GB 都给了 C: 分区,并且已经使用了 1.5 GB 的空间。您想将剩余空间中的 2 GB 给 FreeBSD 使用。 为了安装 FreeBSD,您必须从下面两种方式中选择一种: 备份 &windows; 的数据资料,然后重新安装 &windows;, 并给 &windows; 分配 2 GB 的空间。 使用上面提及的 &partitionmagic; 来整理或切割您的分区。 Alpha 体系结构的硬盘分配方式 Alpha 在 Alpha 上,您必须使用一整颗硬盘给 FreeBSD, 没有办法在同一个硬盘上跟其它操作系统共存。 根据不同的 Alpha 机器,您的硬盘可以是 SCSI 或 IDE 硬盘, 只要您的机器可以从这些硬盘开机就可以。 按照 Digital/Compaq 使用手册书写的惯例, 所有 SRM 输入的部分都用大写表示。 注意,SRM 大小写有别。 要想得知您硬盘的名称以及型号, 可以在 SRM console 提示符下使用 SHOW DEVICE 命令: >>>SHOW DEVICE dka0.0.0.4.0 DKA0 TOSHIBA CD-ROM XM-57 3476 dkc0.0.0.1009.0 DKC0 RZ1BB-BS 0658 dkc100.1.0.1009.0 DKC100 SEAGATE ST34501W 0015 dva0.0.0.0.1 DVA0 ewa0.0.0.3.0 EWA0 00-00-F8-75-6D-01 pkc0.7.0.1009.0 PKC0 SCSI Bus ID 7 5.27 pqa0.0.0.4.0 PQA0 PCI EIDE pqb0.0.1.4.0 PQB0 PCI EIDE 此范例使用 Digital Personal Workstation 433au 并且显示出此机器联接有三个硬盘。第一个是 CDROM,叫做 DKA0;另外两个是两个硬盘,分别叫做 DKC0DKC100 硬盘名称中有 DKx 字样的是 SCSI 硬盘。 例如 DKA100 表示是一个 SCSI 设备, 其 SCSI ID 为 1,位于第一个 SCSI 接口 (A)。 DKC300 表示一个 SCSI 硬盘, SCSI ID 为 3,位于第三个 SCSI 接口 (C)。设备名称 PKx 表示 SCSI 控制卡。由以上 SHOW DEVICE 指令的输出结果看来, SCSI 光盘也被视为是 SCSI 硬盘的一种。 IDE 硬盘的名称类似 DQx,而 PQx 则表示相对应的硬盘控制器。 收集您的网络配置相关资料 如果您想通过网络(FTP 或是 NFS)安装 FreeBSD, 那么您就必须知道您的网络配置信息。在安装 FreeBSD 的过程中将会提示您输入这些资料,以顺利完成安装过程。 使用以太网或电缆/DSL Modem 如果您通过局域网或是要通过网卡使用电缆/DSL 上网, 那么您必须准备下面的信息: IP 地址。 默认网关 IP 地址。 主机名称。 DNS 服务器的 IP 地址。 子网掩码。 如果您不知道这些信息, 您可以询问系统管理员或是您的网络服务提供者。 他们可能会说这些信息会由 DHCP 自动分配;如果这样的话,请记住这一点就可以了。 使用 Modem 连接 如果您由 ISP 提供的拨号服务上网,您仍然可以通过它安装 FreeBSD,只是会需要很长的时间。 您必须知道: 拨号到 ISP 的电话号码。 您的 modem 是连接到哪个 COM 端口。 您拨号到 ISP 所用的账号和密码。 检查 FreeBSD 发行勘误 虽然我们尽力确保每个 FreeBSD 发行版本的稳定性, 但偶尔也会有一些错误进入发行版。极少数情况下, 这些问题甚至可能会影响安装。 当发现和修正问题之后,它们会列在 FreeBSD 网站中的 FreeBSD 发行勘误 中。 在您安装之前,应该首先看一看这份勘误表,以了解可能存在的问题。 关于所有释出版本的信息,包括勘误表,可以在 FreeBSD 网站发行版信息 一节中找到。 准备安装介质 FreeBSD 可以通过下面任何一种安装介质进行安装: 安装介质 CDROM 或 DVD 在同一计算机上的 DOS 分区 SCSI 或 QIC 磁带 软盘 网络 通过防火墙的一个 FTP 站点,或使用 HTTP 代理。 NFS 服务器 一个指定的并行或串行接口 如果您购买了 FreeBSD 的 CD 或 DVD,那么您可以直接进入下一节 如果您还没有 FreeBSD 的安装文件,您应该回到 一节, 它介绍了如何准备所需要的安装介质。之后,您就可以回到这一节, 并从 继续。 准备引导介质 FreeBSD 的安装过程开始于将您的电脑开机进入 FreeBSD 安装环境 — -并非在其它的操作系统上运行一个程序。 计算机通常使用安装在硬盘上的操作系统进行引导, 也可以配置成使用一张bootable(可引导)的软盘进行启动。 大多数现代计算机都可以从光驱进行引导系统。 如果您有 FreeBSD 的安装光盘或 DVD(或者是您购买的, 或者是您自己准备的。)并且您的计算机可以从光驱进行启动 (通常在 BIOS 中会有 Boot Order 或类似的选项可以设置),那么您就可以跳过此小节。 因为 FreeBSD 光盘及 DVD 光盘都是可以引导的, 用它们开机您不用做什么特别的准备。 一般来说,要建立安装盘(软盘)请依照下列步骤: 获取开机软盘映像文件 开机软盘映像文件可以在您的安装介质的 floppies/ 目录下找到, 另外您也可以从下述网站的 floppies 目录下载: ftp://ftp.FreeBSD.org/pub/FreeBSD/releases/<架构名>/<版本>-RELEASE/floppies/. 将 <架构名><版本> 替换为您使用的计算机体系结构和希望安装的版本号。 例如,用于安装 &i386; 上的 &os;/&arch.i386; &rel.current;-RELEASE 的文件的地址, 应该是 软盘映像文件的扩展名是 .flp。 在 floppies/ 目录中包括了许多不同的映像文件, 随您安装的 FreeBSD 版本, 某些时候也随硬件的不同, 您需要使用的映像文件可能会有所不同。 您通常会需要四张软盘, 即 boot.flpkern1.flpkern2.flp, 以及 kern3.flp。 请查阅同一目录下的 README.TXT 文件以了解关于这些映像文件的最新信息。 您的 FTP 程序必须使用 二进制模式 来下载这些映 像文件。有些浏览器只会用 text (或ASCII ) 模式来传输数据, 用这些浏览器下载的映像文件做成的软盘将无法正常开机。 准备软盘 您必须为您下载的每一个映像文件准备一张软盘。 并且请避免使用到坏掉的软盘。 最简单的方式就是您先将这些软盘格式化, 不要相信所谓的已格式化的软盘。在 &windows; 下的格式化程序不会告诉您出现多少坏块, 它只是简单的标记它们为 bad 并且忽略它们。 根据建议您应该使用全新的软盘来存放安装程序。 如果您在安装 FreeBSD 的过程中造成当机、 冻结或是其它怪异现象,第一个要怀疑的就是引导软盘。 请用其它的软盘制作映像文件再试试看。 将映像文件写入软盘中 .flp 文件 并非 一般的文件,您不能直接将它们复制到软盘上。 事实上它是一张包含完整磁盘内容的映像文件。这表示您 不能 简单的使用 DOS 的 copy 命令将文件写到软盘上, 而必须使用特别的工具程序将映像文件直接写到软盘中。 DOS 如果您使用 &ms-dos; 或 &windows; 操作系统来制作引导盘, 那么您可以使用我们提供的 fdimage 程序来将映像文件写到软盘中。 如果您使用的是光盘,假设光盘的驱动器符号为 E:,那么请执行下面的命令: E:\> tools\fdimage floppies\boot.flp A: 重复上述命令以完成每个 .flp 文件的写入, 每换一个映像文件都必须更换软盘; 制作好的软盘请注明是使用哪个映像文件做的。 如果您的映像文件存放在不同的地方,请自行修改上面的指令指向您存放 .flp 文件的地方。要是您没有 FreeBSD 光盘, 您可以到 FreeBSD 的 FTP 站点 tools目录 中下载。 如果您在 &unix; 系统上制作软盘(例如其它 FreeBSD 机器), 您可以使用 &man.dd.1; 命令来将映像文件写到软盘中。 如果您用 FreeBSD,可以执行下面的命令: &prompt.root; dd if=boot.flp of=/dev/fd0 在 FreeBSD 中,/dev/fd0 指的是第一个软驱(即 A: 驱动器); /dev/fd1B: 驱动器,依此类推。其它的 &unix; 系统可能会用不同的的名称, 这时您就要查阅该系统的说明文件。 您现在可以安装 FreeBSD 了
开始安装 默认情况下, 安装过程并不会改变任何您硬盘中的数据, 除非您看到下面的讯息: Last Chance: Are you SURE you want continue the installation? If you're running this on a disk with data you wish to save then WE STRONGLY ENCOURAGE YOU TO MAKE PROPER BACKUPS before proceeding! We can take no responsibility for lost disk contents! 在看到这最后的警告讯息前您都可以随时离开, 安装程序界面不会变更您的硬盘。如果您发现有任何设定错误, 这时您可以直接将电源关掉而不会造成任何伤害。 开机启动 引导 &i386; 系统 从电脑尚未开机开始说起 将电脑电源打开。刚开始的时候它应该会显示进入系统设置菜单或 BIOS 要按哪个键,常见的是 F2F10Del Alt S 。不论是要按哪个键,请按它进入 BIOS 设置画面。 有时您的计算机可能会显示一个图形画面,典型的做法是按 Esc 将关掉这个图形画面, 以使您能够看到必要的设置信息。 找到设置开机顺序的选项,它的标记为 Boot Order 通常会列出一些设备让您选择,例如:FloppyCDROMFirst Hard Disk 等等。 如果您要用软盘安装,请确定选到 floppy disk; 如果您要用光盘安装,请选择 CDROM。为了避免疑惑, 请参考您的主板说明手册。 储存设定并离开,系统应该会重新启动。 如果您用软盘安装,请将在 一节中制作好的第一张引导盘,里面包含kern.flp boot.flp 文件的那张盘, 放入软盘驱动器中。 如果您是从光盘安装, 那么开机后请将 FreeBSD 光盘放入光驱中。 如果您开机后如往常一样并没有从软盘或光盘引导,请检查: 是不是软盘或光盘太晚放入面错失开机引导时间。 如果是, 请将它们放入后重新开机。 BIOS 设定不对,请重新检查 BIOS 的设定。 您的 BIOS 不支持从这些安装介质引导。 FreeBSD 即将启动。如果您是从光盘引导, 您会见到类似下面的画面: Booting from CD-Rom... CD Loader 1.2 Building the boot loader arguments Looking up /BOOT/LOADER... Found Relocating the loader and the BTX Starting the BTX loader BTX loader 1.00 BTX version is 1.01 Console: internal video/keyboard BIOS CD is cd0 BIOS drive C: is disk0 BIOS drive D: is disk1 BIOS 639kB/261120kB available memory FreeBSD/i386 bootstrap loader, Revision 1.1 Loading /boot/defaults/loader.conf /boot/kernel/kernel text=0x64daa0 data=0xa4e80+0xa9e40 syms=[0x4+0x6cac0+0x4+0x88e9d] \ 如果您从软盘启动, 则应看到类似下面的画面: Booting from Floppy... Uncompressing ... done BTX loader 1.00 BTX version is 1.01 Console: internal video/keyboard BIOS drive A: is disk0 BIOS drive C: is disk1 BIOS 639kB/261120kB available memory FreeBSD/i386 bootstrap loader, Revision 1.1 Loading /boot/defaults/loader.conf /kernel text=0x277391 data=0x3268c+0x332a8 | Insert disk labelled "Kernel floppy 1" and press any key... 请根据提示将 boot.flp 软盘取出, 插入 kern1.flp 这张盘, 然后按 Enter。 您只需从第一张软盘启动, 然后再需要时根据提示插入其他软盘就可以了。 不论是从软盘或光盘引导, 接下来都会进入 &os; 引导加载器菜单:
&os; Boot Loader Menu
您可以等待十秒, 或按 Enter
引导 Alpha 系统 Alpha 从电脑尚未打开电源开始。 打开电脑电源并等待屏幕上出现开机提示信息。 如您需要制作用于安装的软盘,请参考 , 将其中一张制作为第一片引导盘,其中包含 boot.flp。将这张软盘插进软驱, 并输入下列命令,以便从软盘启动 (请视实际情况修改命令中的软驱盘符): >>>BOOT DVA0 -FLAGS '' -FILE '' 如果您要从光盘引导, 请将光盘放入光驱中然后输入下列命令开始安装 (请视情况修改命令中的光驱盘符): >>>BOOT DKA0 -FLAGS '' -FILE '' 然后 FreeBSD 就会启动。如果您从软盘引导, 到某个阶段您会看到下面的信息: Insert disk labelled "Kernel floppy 1" and press any key... 此时应按照提示取出 boot.flp 软盘, 换上 kern1.flp 软盘, 然后按 Enter 键。 不论从软盘或光盘引导,您都会看到下面这段信息: Hit [Enter] to boot immediately, or any other key for command prompt. Booting [kernel] in 9 seconds... _ 您可以等待 10 秒或是按 Enter 跳过。 之后就会进入内核设定菜单。 引导 &sparc64; 多数 &sparc64; 系统均配置为从硬盘自动引导。 如果希望安装 &os;,就需要从网络或 CDROM 启动了, 这需要首先进入 PROM (OpenFirmware)。 要完成这项工作,首先需要重启系统,并等待出现引导消息。 具体的信息取决于您使用的型号,不过它应该会是类似下面这样: Sun Blade 100 (UltraSPARC-IIe), Keyboard Present Copyright 1998-2001 Sun Microsystems, Inc. All rights reserved. OpenBoot 4.2, 128 MB memory installed, Serial #51090132. Ethernet address 0:3:ba:b:92:d4, Host ID: 830b92d4. 如果您的系统此时开始了从硬盘引导的过程,则需要按下 L1A StopA , 或者在串口控制台上发送 BREAK (例如, 在 &man.tip.1; 或 &man.cu.1; 中是 ~#) 以便进入 PROM 提示符。 它应该是类似下面这样: ok ok {0} 这是在只有一颗 CPU 的系统上的提示。 这是用于 SMP 系统的选项, 这里的数字, 是系统中可用的 CPU 数量。 这时, 将 CDROM 插入驱动器, 并在 PROM 提示符后面, 输入 boot cdrom
查看设备探测的结果 前面屏幕显示的最后几百行字会存在缓冲区中以便您查阅。 要浏览缓冲区,您可以按下 Scroll Lock 键, 这会开启画面的卷动功能。然后您就可以使用方向键或 PageUpPageDown 键来上下翻阅。 再按一次 Scroll Lock 键将停止画面卷动。 在您浏览的时候会看到类似 的画面。 真正的结果依照您的电脑装置而有所不同。
典型的设备探测结果 avail memory = 253050880 (247120K bytes) Preloaded elf kernel "kernel" at 0xc0817000. Preloaded mfs_root "/mfsroot" at 0xc0817084. md0: Preloaded image </mfsroot> 4423680 bytes at 0xc03ddcd4 md1: Malloc disk Using $PIR table, 4 entries at 0xc00fde60 npx0: <math processor> on motherboard npx0: INT 16 interface pcib0: <Host to PCI bridge> on motherboard pci0: <PCI bus> on pcib0 pcib1:<VIA 82C598MVP (Apollo MVP3) PCI-PCI (AGP) bridge> at device 1.0 on pci0 pci1: <PCI bus> on pcib1 pci1: <Matrox MGA G200 AGP graphics accelerator> at 0.0 irq 11 isab0: <VIA 82C586 PCI-ISA bridge> at device 7.0 on pci0 isa0: <iSA bus> on isab0 atapci0: <VIA 82C586 ATA33 controller> port 0xe000-0xe00f at device 7.1 on pci0 ata0: at 0x1f0 irq 14 on atapci0 ata1: at 0x170 irq 15 on atapci0 uhci0 <VIA 83C572 USB controller> port 0xe400-0xe41f irq 10 at device 7.2 on pci 0 usb0: <VIA 83572 USB controller> on uhci0 usb0: USB revision 1.0 uhub0: VIA UHCI root hub, class 9/0, rev 1.00/1.00, addr1 uhub0: 2 ports with 2 removable, self powered pci0: <unknown card> (vendor=0x1106, dev=0x3040) at 7.3 dc0: <ADMtek AN985 10/100BaseTX> port 0xe800-0xe8ff mem 0xdb000000-0xeb0003ff ir q 11 at device 8.0 on pci0 dc0: Ethernet address: 00:04:5a:74:6b:b5 miibus0: <MII bus> on dc0 ukphy0: <Generic IEEE 802.3u media interface> on miibus0 ukphy0: 10baseT, 10baseT-FDX, 100baseTX, 100baseTX-FDX, auto ed0: <NE2000 PCI Ethernet (RealTek 8029)> port 0xec00-0xec1f irq 9 at device 10. 0 on pci0 ed0 address 52:54:05:de:73:1b, type NE2000 (16 bit) isa0: too many dependant configs (8) isa0: unexpected small tag 14 orm0: <Option ROM> at iomem 0xc0000-0xc7fff on isa0 fdc0: <NEC 72065B or clone> at port 0x3f0-0x3f5,0x3f7 irq 6 drq2 on isa0 fdc0: FIFO enabled, 8 bytes threshold fd0: <1440-KB 3.5” drive> on fdc0 drive 0 atkbdc0: <Keyboard controller (i8042)> at port 0x60,0x64 on isa0 atkbd0: <AT Keyboard> flags 0x1 irq1 on atkbdc0 kbd0 at atkbd0 psm0: <PS/2 Mouse> irq 12 on atkbdc0 psm0: model Generic PS/@ mouse, device ID 0 vga0: <Generic ISA VGA> at port 0x3c0-0x3df iomem 0xa0000-0xbffff on isa0 sc0: <System console> at flags 0x100 on isa0 sc0: VGA <16 virtual consoles, flags=0x300> sio0 at port 0x3f8-0x3ff irq 4 flags 0x10 on isa0 sio0: type 16550A sio1 at port 0x2f8-0x2ff irq 3 on isa0 sio1: type 16550A ppc0: <Parallel port> at port 0x378-0x37f irq 7 on isa0 pppc0: SMC-like chipset (ECP/EPP/PS2/NIBBLE) in COMPATIBLE mode ppc0: FIFO with 16/16/15 bytes threshold plip0: <PLIP network interface> on ppbus0 ad0: 8063MB <IBM-DHEA-38451> [16383/16/63] at ata0-master UDMA33 acd0: CD-RW <LITE-ON LTR-1210B> at ata1-slave PIO4 Mounting root from ufs:/dev/md0c /stand/sysinstall running as init on vty0
请仔细检查探测结果以确定 FreeBSD 找到所有您期望出现的设备。 如果系统没有找到设备, 则不会将其列出。 定制内核 能够让您为系统添加默认的 GENERIC 内核所不支持的设备, 如声卡等。 在 &os; 6.2 和更高版本中, 在探测完系统设备之后, 将显示 。 请使用光标键来选择国家或地区。 接着按 Enter, 系统将自动设置地区及键盘映射。 您也可以很容易地退出 sysinstall 程序并从头来过。
选择国家及地区菜单
选择离开 Sysinstall
在主界面使用方向键选择 Exit Install 您会看到 如下的信息: User Confirmation Requested Are you sure you wish to exit? The system will reboot (be sure to remove any floppies/CDs/DVDs from the drives). [ Yes ] No 如果 CDROM 还留在光驱里,而且选择了 &gui.yes;, 则安装程序将重新启动。 如果您是从软盘启动, 则在重启系统之前, 需要将 boot.flp 软盘取出。
介绍 Sysinstall sysinstall 是 FreeBSD 项目所提供的安装程序。它以 console(控制台)为主, 分为多个菜单及画面让您配置及控制安装过程。 sysinstall 菜单画面由方向键、 EnterTabSpace, 以及其它按键所控制。在主画面的 Usage 菜单有这些按键的说明。 要查看这些说明,请将光标移到 Usage 项目,然后 [Select] 按键被选择, ,然后按下 Enter 键。 安装画面的使用说明会显示出来,阅读完毕请按 Enter 键回到主画面。
选取 Sysinstall 主菜单的 Usage 项目
选择 Documentation(说明文件) 菜单 用方向键从主菜单选择 Doc 条目然后按 Enter键。
选择说明文件菜单
这将会进入说明文件菜单。
Sysinstall 说明文件菜单
阅读这些说明文件很重要。 要阅读一篇文章,请用方向键选取要阅读的文章然后按 Enter 键。阅读中再按一下 Enter 就会回到说明文件画面。 若要回到主菜单,用方向键选择 Exit 然后按下 Enter 键。
选择键盘对应(Keymap)菜单 如果要改变键盘按键的对应方式, 请在主菜单选取 Keymap 然后按 Enter 键。一般情况下不改变此项, 除非您使用了非标准键盘或非美国键盘。
Sysinstall 主菜单
您可以使用上下键移动到您想使用的键盘对应方式, 然后按下 Space 键以选取它;再按 Space 键可以取消选取。当您完成后, 请选择 &gui.ok; 然后按 Enter 键。 这一屏幕只显示出部分列表。选择 &gui.cancel; 按 Tab 键将使用默认的键盘对应, 并返回到主菜单
Sysinstall 键盘对应菜单
安装选项设置画面 选择 Options 然后按 Enter 键。
Sysinstall 主菜单
Sysinstall 选项设置
预设值通常可以适用于大部分的使用者,您并不需要改变它们。 版本名称要根据安装的版本进行变化。 目前选择项目的描述会在屏幕下方以蓝底白字显示。 注意其中有一个项目是 Use Defaults(使用默认值) 您可以由此项将所有的设定还原为预设值。 可以按下 F1 来阅读各选项的说明。 Q 键可以回到主画面。
开始进行标准安装 Standard(标准) 安装适用于那些 &unix; 或 FreeBSD 的初级使用者。用方向键选择 Standard 然后按 Enter 键可开始进入标准安装。
开始进行标准安装
分配磁盘空间 您的第一个工作就是要分配 FreeBSD 用的硬盘空间以便 sysinstall 先做好一些准备。 为了完成这个工作,您必须先对 FreeBSD 如何找到磁盘信息做一个了解。 BIOS 磁盘编号 当您在系统上安装配置 FreeBSD 之前, 有一个重要的事情一定要注意,尤其是当您有多个硬盘的时候。 DOS Microsoft Windows 在 pc 架构,当您跑像 &ms-dos; 或 µsoft.windows; 这种跟 BIOS 相关的操作系统的时候,BIOS 有能力改变正常的磁盘顺序, 然后这些操作系统会跟着 BIOS 做改变。这让使用者不一定非要有所谓的 primary master 硬盘开机。 许多人发现最简单而便宜备份系统的方式就是再去买一块一模一样的硬盘, 然后定期将数据从第一块硬盘复制到第二个硬盘,使用 GhostXCOPY。所以,当第一个硬盘死了, 或者是被病毒破坏,或者有坏轨道, 他们可以调整 BIOS 中的开机顺序而直接用第二块硬盘开机。 就像交换硬盘的数据线,但是无需打开机箱。 SCSI BIOS 比较昂贵,配有 SCSI 控制卡的系统通常可以延伸 BIOS 的功能来让 SCSI 设备 (可达七个) 达到类似改变顺序的功能。 习惯于使用这种方式的使用者可能会感到惊讶, 因为在 FreeBSD 中并非如此。FreeBSD 不会参考 BIOS, 而且也不知道所谓的 BIOS 逻辑磁盘对应 是怎么回事。这会让人感觉很疑惑, 明明就是一样的硬盘而且资料也完全从另一块复制过来的, 结果却没办法像以前那样用。 当使用 FreeBSD 以前,请将 BIOS 中的硬盘开机顺序调回正常的顺序, 并且以后不要再改变。 如果一定要交换硬盘顺序, 那请用硬件的方式, 打开机箱并调整调线。 范例:Bill 和 Fred 的安装历险 Bill 替 Fred 把旧的 Wintel 的机器装上了 FreeBSD。 他装了一台 SCSI 硬盘,ID 是 0,然后把 FreeBSD 装在上面。 Fred 开始使用他新的 FreeBSD 系统;但是过了几天, 他发现这旧的 SCSI硬盘发生了许多小问题。之后, 他就跟 Bill 说起这件事。 又过了几天,Bill 决定是该解决问题的时候了, 所以他从后面房间的硬盘 收藏 中找出了一个一模一样的硬盘,并且经过表面测试后显示这块硬盘没有问题。 因此,Bill 将它的 ID 调成 4,然后安装到 Fred 的机器, 并且将资料从磁盘 0 复制到磁盘 4。现在新硬盘装好了, 而且看起来好像一切正常;所以,Bill 认为现在应该可以开始用它了。 Bill 于是到 SCSI BIOS 中设定 SCSI ID 4 为开机盘,用磁盘 4 重新开机后,一切跑得很顺利。 继续用了几天后,Bill 跟 Fred 决定要来玩点新的: 该将 FreeBSD 升级了。Bill 将 ID 0 的硬盘移除 (因为有问题) 并且又从收藏区中拿了一块一样的硬盘来。然后他用 Fred 神奇的网络 FTP 磁盘将新版的 FreeBSD 安装在这块硬盘上; 安装过程没什么问题发生。 Fred 用了这新版本几天后,觉得它很适合用在工程部门… 是时候将以前放在旧系统的工作资料复制过来了。 因此, Fred 将 ID4 的 SCSI 硬盘 (里面有放着旧系统中复制过来的最新资料) mount 起来,结果竟然发现在 ID4 的硬盘上, 他以前的所有资料都不见了! 资料跑到哪里去了呢? 当初 Bill 将 ID0 硬盘的资料复制到 ID4 的时候, ID4 即成为一个 新的副本。 而当他调 SCSI BIOS 设定 ID4 为开机盘,想让系统从 ID4 开机, 这其实只是他自己笨,因为大部分的系统可以直接调 BIOS 而改变开机顺序, 但是 FreeBSD 却会把开机顺序还原成正常的模式,因此,Fred 的 FreeBSD 还是从原来那块 ID0 的硬盘开机的。所有的资料都还在那块硬盘上, 而不是在想象之中的 ID4 硬盘。 幸运的是, 在我们发现这件事的时候那些资料都还在, 我们将这些资料从最早的那块 ID0 硬盘取出来并交还给 Fred, 而 Bill 也由此了解到计算机计数是从 0 开始的。 虽然我们这里的例子使用 SCSI 硬盘, 但是相同的概念也可以套用在 IDE 硬盘上。 使用 FDisk 创建分区 如果不再做改变,数据将会写进硬盘。如果您犯了一个错误想重新开始, 请选择 sysinstall 安装程序的退出按钮(exit)。或按 U 键来 Undo 操作。 如果您的操作没有结果, 您总可以重新启动您的计算机来达到您的目的。 当您在 sysinstall 主菜单选择使用标准安装后,您会看到下面的信息: Message In the next menu, you will need to set up a DOS-style ("fdisk") partitioning scheme for your hard disk. If you simply wish to devote all disk space to FreeBSD (overwriting anything else that might be on the disk(s) selected) then use the (A)ll command to select the default partitioning scheme followed by a (Q)uit. If you wish to allocate only free space to FreeBSD, move to a partition marked "unused" and use the (C)reate command. [ OK ] [ Press enter or space ] 如屏幕指示,按 Enter 键, 然后您就会看到一个列表列出所有在探测设备的时候找到的硬盘。 范例显示的是有找到两个 IDE 硬盘的情形,这两个硬盘分别为 ad0ad2
选择要分区的硬盘
您可能正在奇怪,为什么 ad1 没有列出来? 为什么遗失了呢? 试想,如果您有两个 IDE 硬盘,一个是在第一个 Primary master, 一个是 Secondary master,这样会发生什么事呢? 如果 FreeBSD 依照找到的顺序来为他们命名,如 ad0ad1 那么就不会有什么问题。 但是,现在问题来了。如果您现在想在 primary slave 加装第三个硬盘, 那么这个硬盘的名称就会是 ad1,之前的 ad1 就会变成 ad2。 这会造成什么问题呢?因为设备的名称 (如 ad1s1a)是用来寻找文件系统的, 因此您可能会发现,突然,您有些文件系统从此无法正确地显示出来, 必须修改 FreeBSD 配置文件(译注:/etc/fstab)才可以正确显示。 为了解决这些问题,在配置内核的时候可以叫 FreeBSD 直接用 IDE 设备所在的位置来命名,而不是依据找到的顺序。使用这种方式的话, 在 secondary master 的 IDE 设备就 永远是 ad2,即使您的系统中没有 ad0ad1 也不受影响。 此为 FreeBSD 内核的默认值,这也是为什么上面的画面只显示 ad0ad2 的原因。 画面上这台机器的两颗硬盘是装在 primary 及 secondary 的 master 上面; 并没有任何一个硬盘安装在 slave 插槽上。 您应该选择您想安装 FreeBSD 的硬盘,然后按下 &gui.ok;。之后 FDisk 就会开始,您会看到类似 的画面。 FDisk 的显示画面分为三个部分。 第一部分是画面上最上面两行,显示的是目前所选择的硬盘的信息。 包含它的 FreeBSD 名称、硬盘分布以及硬盘的总容量。 第二部分显示的是目前选择的硬盘上有哪些分区, 每个分区的开始及结束位置、所占容量、FreeBSD 名称、 它们的描述以及类别(sub-type)。此范例显示有两个未使用的小分区, 还有一个大的 FAT 分区, (很可能是 &ms-dos; 或 &windows; 的 C: ), 以及一个扩展分区(在 &ms-dos; 或 &windows; 里面还可以包含逻辑分区)。 第三个部分显示 FDisk 中可用的命令。
典型的尚未编辑前的 Fdisk 分区表
接下来要做的事跟您要怎么给您的硬盘分区有关。 如果您要让 FreeBSD 使用整个硬盘(稍后您确认要 sysinstall 继续安装后会删除所有这个硬盘上的资料),那么您就可以按 A 键(Use Entire Disk ) 目前已有的分区都会被删除,取而代之的是一个小的,标示为 unused 的分区,以及一个大的 FreeBSD 分区。之后, 请用方向键将光标移到这个 FreeBSD 分区,然后按 S 以将此分区标记为启动分区。 您会看到类似 的画面。注意,在 Flags 栏中的 A 记号表示此分区是 激活 的, 因而启动将从此分区进行。 要删除现有的分区以便为 FreeBSD 腾出空间, 您可以将光标移动到要删除的分区后按 D 键。 然后就可按 C 键, 并在弹出的对话框中输入将要创建的分区的大小。 输入合适的大小后按 Enter 键。 一般而言, 这个对话框中的初始值是可以分配给该分区的最大值。 它可能是最大的邻接分区或未分配的整个硬盘大小。 如果您已经建立好给 FreeBSD 的分区 (使用像 &partitionmagic;类似的工具), 那么您可以按下 C 键来建立一个新的分区。同样的, 会有对话框询问您要建立的分区的大小。
Fdisk 分区使用整个硬盘
完成后,按 Q 键。您的变更会存在 sysinstall 中, 但是还不会真正写入您的硬盘。
安装多重引导 在这步骤您可以选择要不要安装一个多重引导管理器。 一般而言,如果碰到下列的情形, 您应该选择要安装多重引导管理程序。 您有一个以上的硬盘,并且 FreeBSD 并不是安装在第一个硬盘上。 除了 FreeBSD,您还有其它的操作系统安装在同一块硬盘上, 所以您需要在开机的时候选择要进入哪一个系统。 如果您在这台机器上只安装一个 FreeBSD 操作系统, 并且安装在第一个硬盘, 那么选择 Standard 安装就可以了。如果您已经使用了一个第三方的多重引导程序, 那么请选择 None 选择好配置后请按 Enter
Sysinstall 多重引导管理程序
按下 F1 键所显示的在线说明中有讨论一些操作系统共存可能发生的问题。
在其它硬盘上创建分区 如果您的系统上有一个以上的硬盘, 在选择完多重引导管理程序后会再回到选择硬盘的画面。 如果您要将 FreeBSD 安装在多个硬盘上,那么您可以在这里选择其它的硬盘, 然后重复使用 FDisk 来建立分区。 如果您想让 FreeBSD 来管理其它的硬盘, 那么两个硬盘都必须安装 FreeBSD 的多重引导管理程序。
离开选择硬盘画面
Tab 键可以在您最后选择的硬盘、 &gui.ok; 以及 &gui.cancel; 之间进行切换。 Tab 键将光标移动到 &gui.ok; 然后按 Enter 键继续安装过程。
使用 <application>bsdlabel</application> 创建分区 您现在必须在刚刚建立好的 slice 中规划一些 label。 请注意,每个 label 的代号是 ah,另外,习惯上 bcd 是有特殊用途的,不应该随意变动。 某些应用程序可以利用一些特殊的分区而达到较好的效果, 尤其是分区分散在不同的硬盘的时候。但是,现在您是第一次安装FreeBSD, 所以不需要去烦恼如何分割您的硬盘。最重要的是, 装好FreeBSD然后学习如何使用它。当您对FreeBSD有相当程度的熟悉后, 您可以随时重新安装FreeBSD,然后改变您分区的方式。 下面的范例中有四个分区 — 一个是磁盘交换分区,另外三个是文件系统。 为第一个硬盘分区 分区 文件系统 大小 描述 a / 512 MB 这是一个根文件系统(root filesystem)。 任何其它的文件系统都会 挂在根目录(译注:用根目录比较亲切) 下面。 512 MB 对于此目录来说是合理的大小, 因为您往后并不会在这里存放太多的数据; 在安装 FreeBSD 后会用掉约 128 MB 的根目录空间。 剩下的空间是用来存放临时文件用的,同时, 您也应该预留一些空间,因为以后的FreeBSD版本可能会需要较多的 /(根目录)空间。 b N/A 2-3 x RAM b 分区为系统磁盘交换分区 (swap space)。选择正确的交换空间大小可是一门学问唷。 一般来说,交换空间的大小应该是您系统上内存(RAM) 大小的2到3倍。 交换空间至少要有 64 MB。因此, 如果您的电脑上的 RAM 比 32 MB 小, 请将交换空间大小设为 64 MB。 如果您有一个以上的硬盘, 您可以在每个硬盘上都配置交换分区。FreeBSD 会利用每个硬盘上的交换空间,这样做能够提高 swap 的性能。 如果是这种情形, 先算出您总共需要的交换空间大小 (如128 MB),然后除以您拥有的硬盘数目(如2块), 算出的结果就是每个硬盘上要配置的交换空间的大小。 在这个例子中, 每个硬盘的交换空间为 64 MB。 e /var 256 MB 至 1024 MB /var 目录会存放不同长度的文件、 日志以及其它管理用途的文件。大部分这些文件都是 FreeBSD 每天在运行的时候会读取或是写入的。 当这些文件放在另外的文件系统(译注:即/var) 可以避免影响到其它目录下面类似的文件存取机制。 f /usr 剩下的硬盘空间 (至少 2 GB) 您所有的其它的文件通常都会存在/usr 目录以及其子目录下面。
上面例子中的数值仅限于有经验的用户使用。 通常我们鼓励用户使用 &os; 分区编辑器中一个叫做 Auto Defaults的自动分区布局功能。 如果您要将FreeBSD安装在一个以上的硬盘, 那么您必须在您配置的其它分区上再建立分区。 最简单的方式就是在每个硬盘上建立两个分区,一个是交换分区, 一个是文件系统分区。 为其它磁盘分区 分区 文件系统 大小 描述 b N/A 见描述 之前提过,交换分区是可以跨硬盘的。但是,即使 a 分区没有使用,习惯上还是会把交换分区放在 b 分区上。 e /diskn 剩下的硬盘空间 剩下的空间是一个大的分区,最简单的做法是将之规划为 a分区而不是e分区。然而, 习惯上a分区是保留给根目录 (/) 用的。您不一定要遵守这个习惯,但是 sysinstall 会, 所以照着它做会使您的安装比较清爽、干净。 您可以将这些文件系统挂在任何地方,本范例建议将它们挂在 /diskn 目录,n 依据每个硬盘而有所不同, 但是,您喜欢的话也可将它们挂在别的地方。
分区的配置完成后,您可以用sysinstall. 来建立它们了。您会看到下面的信息: Message Now, you need to create BSD partitions inside of the fdisk partition(s) just created. If you have a reasonable amount of disk space (200MB or more) and don't have any special requirements, simply use the (A)uto command to allocate space automatically. If you have more specific needs or just don't care for the layout chosen by (A)uto, press F1 for more information on manual layout. [ OK ] [ Press enter or space ] 按下 Enter 键开始FreeBSD分区表编辑器,称做 Disklabel 显示您第一次执行 Disklabel的画面。 画面分为三个区域。 前几行显示的是您正在编辑的硬盘以及您正在建立的 slice 位于哪个分区上。(在这里,Disklabel 使用的是 分区名称 而不是 slice 名)。 此画面也会显示 slice 还有多少空间可以使用;亦即,有多余的空间, 但是尚未指派分区。 画面中间区域显示已建立的区区,每个分区的文件系统名称、 所占的大小以及一些关于建立这些文件系统的参数选项。 下方的第三区显示在 Disklabel 中可用的按键。
Sysinstall Disklabel 编辑器
Disklabel 您可以自动配置分区以及给它们预设的大小。 这些默认的分区是由内部的分区尺寸算法根据磁盘的大小计算出的。 您可以按 A键使用此功能。您会看到类似 的画面。根据您硬盘的大小, 自动分配所配置的大小不一定合适。但是没有关系, 您并不一定要使用预设的大小。 默认情况下会给/tmp 目录一个独立分区,而不是附属在 / 之下。 这样可以避免将一些临时文件放到根目录中(译注: 可能会用完根目录空间)。
Sysinstall Disklabel 编辑器-使用自动配置
如果您不想使用默认的分区布局, 则需要用方向键移动光标并选中第一个分区, 然后按 D 来删除它。 重复这一过程直到删除了所有推荐的分区。 要建立第一个分区 (a,作为 / — 根文件系统), 请确认您已经在屏幕顶部选中了正确的 slice, 然后按 C。 接下来将出现一个对话框, 要求您输入新分区的尺寸 (如 所示)。 您可以输入以块为单位的尺寸,或以 M 表示MB、 G 结尾表示GB, 或者 C 表示柱面数的方式来表达尺寸。
根目录使用空间
如果使用此处显示的默认尺寸, 则会创建一个占满整个 slice 空余空间的 partition。如果希望使用前面例子中描述的 partition 尺寸, 则应按 Backspace 键删除这些数字, 并输入 512M, 如 所示。 然后, 按下 &gui.ok;。
编辑要分区大小
输入完大小后接着问您要建立的分区是文件系统还是交换空间,如 所示。第一个分区是文件系统, 所以确认选择 FS后按Enter 键。
选择根分区类型
最后,因为您要建立的是一个文件系统,所以必须告诉 Disklabel 这个文件系统要挂接在什么地方,如 所示。根文件系统的挂接点 /, 所以请输入 /,然后按 Enter键。
选择根挂接点
刚刚制作好的分区会显示在画面上。 您应该重复上述的动作以建立其它的分区。当建立交换空间的时候, 系统不会问您要将它挂接在哪里,因为交换空间是不用挂在系统上的。 当您在建立最后一个分区/usr的时候, 您可以直接使用默认的大小,即所有此分区剩余的空间。 您最终的 FreeBSD DiskLabel 编辑器画面会类似 , 实际数字按您的选择而有所不同。 按下 Q 键完成分区的建立。
Sysinstall Disklabel 编辑器
选择要安装的软件包 选择要安装的软件包 安装哪些软件包在很大程度上取决于系统将被用来做什么, 以及有多少可用的磁盘空间。内建的选项包括了运行所需要的最小系统, 到把所有软件包全都装上的常用配置。&unix; 或 FreeBSD 新手通常直接选择一个设定好的软件包就可以了, 而有经验的使用者则可以考虑自己订制安装哪些软件包。 按下 F1 可以看到有关软件包的更多选项信息, 以及它们都包含了哪些软件,之后,可以按 Enter 回到软件包选择画面。 如果您想要使用图形界面, 则必须选择软件包名称开头是 X 的那些软件包。 对于 X 服务器的配置, 以及选择默认的桌面管理器这样的工作必须在 &os; 安装完成之后才能作。 关于配置 X 服务器的更多资料可以在 找到。 默认安装的 X11 版本是 &xorg; 如果需要定制内核, 您还需要选择包含源代码的那个选项。 要了解为什么应该编译和构建新的内核, 请参见 显然, 包含所有组件的系统是最万能的。 如果磁盘空间足够, 用光标键选择 中的 All 并按 Enter。 如果担心磁盘空间不够的话, 则选择最合适的选项。 不要担心选择的是否是最合适的, 因为其他软件包可以在安装完毕后再加入进来。
选择软件包
安装ports软件包 当选择完您想要安装的部分后,接着会询问您要不要安装FreeBSD Ports 软件包;Ports软件包可以让您简单方便地安装软件包。Ports本身并不包含编辑 软件所需要的程序源代码,而是一个包含自动下载、编辑以及安装的文档集合。 一章讨论如何使用Ports. 安装程序并不会检查您是否有足够的硬盘空间, 在选择这一项之前请先确定您有足够的硬盘空间。 目前 FreeBSD &rel.current; 版本中, FreeBSD Ports Collection 大约占用 &ports.size; 大小的硬盘空间。 对于近期的版本您可能需要更多一些空间来安装他们。 User Confirmation Requested Would you like to install the FreeBSD Ports Collection? This will give you ready access to over &os.numports; ported software packages, at a cost of around &ports.size; of disk space when "clean" and possibly much more than that if a lot of the distribution tarballs are loaded (unless you have the extra CDs from a FreeBSD CD/DVD distribution available and can mount it on /cdrom, in which case this is far less of a problem). The Ports Collection is a very valuable resource and well worth having on your /usr partition, so it is advisable to say Yes to this option. For more information on the Ports Collection & the latest ports, visit: http://www.FreeBSD.org/ports [ Yes ] No 选择 &gui.yes; 将会安装 Ports Collection, 而选择 &gui.no; 则将跳过它。 选好后按 Enter 继续。 此后, 选择安装的软件包的屏幕将再次出现。
确认您要安装的软件包
如果对您的选择感到满意,请选择Exit 退出,确保&gui.ok; 被高亮显示,然后按Enter 继续。
选择您要使用的安装介质 如果要从 CDROM 或 DVD安装,使用方向键将光标移到 Install from a FreeBSD CD/DVD。确认 &gui.ok; 被选取,然后按 Enter 开始安装程序。 如果要使用其它的方式安装, 请选择适当的安装介质然后按照屏幕指示进行安装。 F1 可以显示安装介质的在线说明。按一下 Enter 可返回选择安装介质画面。
选择安装介质
FTP安装模式 installation network FTP 使用FTP安装,有三种方式:主动式(active)FTP、被动式(passive)FTP 或是透过HTTP代理服务器。 主动式FTP: 从FTP服务器安装 这个选项将会使所有的FTP传输使用 Active模式。 这将无法通过防火墙,但是可以使用在那些比较早期, 不支持被动模式的FTP站。如果您的连接在使用被动(默认值) 模式卡住了,请换主动模式看看! 被动模式FTP:通过防火墙从FTP服务器安装 FTP passive mode 此选项会让 sysinstall 使用 Passive模式来安装。这使得使用者可以穿过 不允许用非固定TCP PORTS连入的防火墙。 FTP 透过 HTTP 代理服务器: 透过HTTP代理服务器, 由 FTP 服务器安装 FTP via a HTTP proxy 此选项会让 sysinstall 通过HTTP协议 (像浏览器一样)连到proxy服务器。 proxy服务器会解释送出的请求,然后通知FTP服务器。 因为通过HTTP协议,所以可以穿过防火墙。 要用这种方式,您必须指定proxy服务器的地址。 对于一个 FTP 代理服务器而言, 通常在使用者登入名称中加入您要登入的服务器的用户名, 加在 @ 符号后面。然后代理服务器就会 假装 成一个真的服务器。例如,假设您要从 ftp.FreeBSD.org 安装,通过 FTP 代理服务器 foo.example.com, 使用1234端口。 在这种情况下,您可以到 options 菜单,将 FTP username 设为 ftp@ftp.FreeBSD.org,密码设为您的电子邮件地址。 安装介质部分,指定FTP (或是被动式 FTP,如果代理服务器支持的话) 以及URL为 ftp://foo.example.com:1234/pub/FreeBSD 因为ftp.FreeBSD.org/pub/FreeBSD 目录会被抓取到 foo.example.com之下,您就可以从 这台 机器 (会从 ftp.FreeBSD.org 抓取文件) 安装。
安装确认 到此为止,可以开始进行安装了, 这也是您避免更动到您的硬盘的最后机会。 User Confirmation Requested Last Chance! Are you SURE you want to continue the installation? If you're running this on a disk with data you wish to save then WE STRONGLY ENCOURAGE YOU TO MAKE PROPER BACKUPS before proceeding! We can take no responsibility for lost disk contents! [ Yes ] No 选择 &gui.yes; 然后按下 Enter 确认安装 安装所需的时间会根据您所选择的软件、 安装介质以及您电脑的速度而有所不同。 在安装的过程中会有一些信息来显示目前的进度。 当您看到下面的信息表示已经安装完成了: Message Congratulations! You now have FreeBSD installed on your system. We will now move on to the final configuration questions. For any option you do not wish to configure, simply select No. If you wish to re-enter this utility after the system is up, you may do so by typing: /usr/sbin/sysinstall. [ OK ] [ Press enter or space ] 按下 Enter 以进行安装后的配置。 选择 &gui.no; 然后按 Enter 会取消安装,不会对您的系统造成更动。您会看到下面的信息: Message Installation complete with some errors. You may wish to scroll through the debugging messages on VTY1 with the scroll-lock feature. You can also choose "No" at the next prompt and go back into the installation menus to retry whichever operations have failed. [ OK ] 产生这个信息是因为什么东西也没有安装,按下 Enter 后会离开安装程序回到主安装界面。从主安装界面可以退出安装程序。 安装后的配置 安装成功后, 就可以进行进一步的配置了。 引导新安装的 FreeBSD 系统之后, 使用 sysinstall 并选择 Configure 配置网卡 如果您之前配置用 PPP 通过 FTP 安装,那么这个画面将不会出现; 正像所说的那样,您可以稍后再做配置。 如果想更多的了解网卡或将FreeBSD配置为网关或路由器,请参考 Advanced Networking 的相关文章。 User Confirmation Requested Would you like to configure any Ethernet or SLIP/PPP network devices? [ Yes ] No 如果要配置网卡,请选择 &gui.yes; 然后按 Enter。 否则请选择 &gui.no; 继续。
选择网卡设备
用方向键选择您要配置的网卡接口,然后按Enter User Confirmation Requested Do you want to try IPv6 configuration of the interface? Yes [ No ] 目录私人区域网络IP协议IPv4已经足够,所以选择 &gui.no; 然后按 Enter 如果想试试新的IP通信协议 IPv6 , 使用 RA 服务,请选择 &gui.yes; 然后按 Enter。 寻找 RA 服务器将会花费几秒的时间。 User Confirmation Requested Do you want to try DHCP configuration of the interface? Yes [ No ] 如果您不需要 DHCP (Dynamic Host Configuration Protocol 动态主机配置协议) ,选择 &gui.no; 然后按Enter 选择 &gui.yes; 会执行dhclient, 如果成功,它会自动将网络配置信息填上。更多的信息请参考 下面的网络配置显示了怎样把以太网设备配置成区域网络网关的角色。
配置 ed0接口
使用Tab 键可以在各个栏目之间进行切换,请输入适当 的信息: Host(机器名称) 完整的机器名称,例如本例中的 k6-2.example.com Domain(域名) 您机器所在的域名称,如本例的 example.com IPv4 Gateway(IPv4网关) 输入将数据包传送到远端网络的机器IP地址。 只有当机器是网络上的一个节点时才要输入。 如果这台机器要作为您局域网的网关, 请将此处设为空白。IPv4网关, 也被称作默认网关或默认路由器。 域名服务器 本地网络中的域名服务器的IP地址。 本例中假设机器所在的网络中没有域名服务器, 所以填入的是ISP提供的域名服务器地址 (208.163.10.2。) IPv4 地址 本机所使用的IP地址。本例为 192.168.0.1 子网掩码 在这个局域网中所使用的地址块是 192.168.0.0 - 192.168.0.255, 对应的子网掩码是 255.255.255.0 ifconfig 额外参数设定 任何ifconfig命令跟网卡接口有关的参数。 本范例中没有。 使用 Tab 键选择 &gui.ok;然后按 Enter键。 User Confirmation Requested Would you like to Bring Up the ed0 interface right now? [ Yes ] No 选择 &gui.yes; 然后按 Enter 将会将机器的网卡转为启用状态。 机器下次启动的时候即可使用。
配置网关 User Confirmation Requested Do you want this machine to function as a network gateway? [ Yes ] No 如果这台机器要作为本地网络和其它机器之间传送数据包的网关,请选择 &gui.yes; 然后按 Enter。 如果这台机器只是网络上的普通节点,请选择 &gui.no; 并按 Enter 继续。 配置网络服务 User Confirmation Requested Do you want to configure inetd and the network services that it provides? Yes [ No ] 如果选择 &gui.no;, 许多网络服务,如 telnetd 将不会启用。 这样, 远端用户将无法 telnet 进入这台机器。 本机上的用户还是可以 telnet到远端机器的。 这些服务可以在安装完成后修改/etc/inetd.conf 配置文件来启用它们。请参阅 以获得更多的信息。 如果您想现在就配置这些网络服务,请选择 &gui.yes;, 然后会看到下面的信息: User Confirmation Requested The Internet Super Server (inetd) allows a number of simple Internet services to be enabled, including finger, ftp and telnetd. Enabling these services may increase risk of security problems by increasing the exposure of your system. With this in mind, do you wish to enable inetd? [ Yes ] No 选择 &gui.yes; 继续。 User Confirmation Requested inetd(8) relies on its configuration file, /etc/inetd.conf, to determine which of its Internet services will be available. The default FreeBSD inetd.conf(5) leaves all services disabled by default, so they must be specifically enabled in the configuration file before they will function, even once inetd(8) is enabled. Note that services for IPv6 must be separately enabled from IPv4 services. Select [Yes] now to invoke an editor on /etc/inetd.conf, or [No] to use the current settings. [ Yes ] No 选择 &gui.yes; 将允许您添加网络服务 (或将相应网络服务每行开头的 # 除掉即可。)
编辑 <filename>inetd.conf</filename>配置文件
在加入您想启用的服务后,按下 Esc键会出现一个 对话框可以让您离开以及保存修改。
启用 SSH 登录 SSH sshd User Confirmation Requested Would you like to enable SSH login? Yes [ No ] 选择 &gui.yes; 便会启用 &man.sshd.8;, 也就是 OpenSSH 服务程序。 它能够让您以安全的方式从远程访问机器。 如欲了解关于 OpenSSH 的进一步详情, 请参见 匿名 FTP FTP anonymous User Confirmation Requested Do you want to have anonymous FTP access to this machine? Yes [ No ] 不允许匿名 FTP访问 选择默认的 &gui.no; 并按下 Enter 键将仍然可以让在这台机器上有账号的用户访问 FTP。 允许匿名 FTP访问 如果您选择允许匿名 FTP 存取, 那么网络中任何人都可以使用FTP来访问您的机器。 在启用匿名访问之前应该考虑网络的安全问题。 如果要知道更多有关网络安全的信息, 请参阅 要启用FTP匿名访问,用方向键选择 &gui.yes; 并按 Enter键。 系统会给出进一步的确认信息: User Confirmation Requested Anonymous FTP permits un-authenticated users to connect to the system FTP server, if FTP service is enabled. Anonymous users are restricted to a specific subset of the file system, and the default configuration provides a drop-box incoming directory to which uploads are permitted. You must separately enable both inetd(8), and enable ftpd(8) in inetd.conf(5) for FTP services to be available. If you did not do so earlier, you will have the opportunity to enable inetd(8) again later. If you want the server to be read-only you should leave the upload directory option empty and add the -r command-line option to ftpd(8) in inetd.conf(5) Do you wish to continue configuring anonymous FTP? [ Yes ] No 这些信息会告诉您 FTP 服务还需要在 /etc/inetd.conf 中启用。 假如您希望允许匿名 FTP 连接, 请参见 。 选择 &gui.yes; 并按 Enter 继续; 系统将给出下列信息:
默认的匿名 FTP 配置
使用 Tab 在不同的信息字段之间切换, 并填写必要的信息: UID 用于分配给匿名 FTP 用户的用户 ID。 所有上传的文件的属主都将是这个 ID。 Group 匿名 FTP 用户所在的组。 Comment 用于在 /etc/passwd 中描述该用户的说明性信息。 FTP Root Directory 可供匿名 FTP 用户使用的文件所在的根目录。 Upload Subdirectory 匿名 FTP 用户上传的文件的存放位置。 默认的 FTP 根目录将放在 /var 目录下。 如果您的 /var 目录空间不足以应付您的FTP需求, 您可以将FTP的根目录改为 /usr 目录下的 /usr/ftp 目录。 当您对一切配置都满意后,请按 Enter 键继续。 User Confirmation Requested Create a welcome message file for anonymous FTP users? [ Yes ] No 如果您选择 &gui.yes; 并按下 Enter键, 系统会自动打开文本编辑器让您编辑FTP的欢迎信息。
编辑FTP欢迎信息
此文本编辑器叫做 ee。 按照指示修改信息文本或是稍后再用您喜爱的文本编辑器来修改。 请记住画面下方显示的文件位置。 Esc 将弹出一个默认为 a) leave editor的对话框。按 Enter 退出并继续。再次按 Enter 将保存修改。
配置网络文件系统 网络文件系统 (NFS) 可以让您可以在网络上共享您的文件。 一台机器可以配置成NFS服务器、客户端或两者并存。请参考 以获得更多的信息。 NFS 服务器 User Confirmation Requested Do you want to configure this machine as an NFS server? Yes [ No ] 如果您不想安装网络文件系统,请选择 &gui.no; 然后按 Enter键。 如果您选择 &gui.yes; 将会出现一个对话框提醒您必须先建立一个 exports 文件。 Message Operating as an NFS server means that you must first configure an /etc/exports file to indicate which hosts are allowed certain kinds of access to your local filesystems. Press [Enter] now to invoke an editor on /etc/exports [ OK ] Enter 键继续。系统会启动文本编辑器让您编辑 exports 文件。
编辑 <filename>exports</filename>文件
按照指示加入真实输出的文件目录或是稍后用您喜爱的编辑器自行编辑。 请记下画面下方显示的文件名称及位置。 按下 Esc 键会出现一具对话框,默认选项是 a) leave editor。按下 Enter 离开并继续。
NFS 客户端 NFS 客户端允许您的机器访问NFS服务器。 User Confirmation Requested Do you want to configure this machine as an NFS client? Yes [ No ] 按照您的需要,选择 &gui.yes; 或 &gui.no; 然后按 Enter
配置系统终端 系统提供了几个选项可以让您配置终端的表现方式。 User Confirmation Requested Would you like to customize your system console settings? [ Yes ] No 要查阅及配置这些选项,请选择 &gui.yes; 并按Enter
系统终端配置选项
最常用的选项就是屏幕保护程序了。使用方向键将光标移动到 Saver 然后按 Enter
屏幕保护程序选项
选择您想使用的屏幕保护程序,然后按 Enter。 之后回到系统终端配置画面。 默认开启屏幕保护程序的时间是300秒。如果要更改此时间,请再次选择 Saver 。然后选择 Timeout 并按 Enter键。系统会弹出一个对话框如下:
屏幕保护时间设置
您可以直接改变这个值,然后选 &gui.ok;并按 Enter 键回到系统终端配置画面。
退出系统终端配置
选择 Exit 然后按下 Enter 键会回到安装后的配置画面。
配置时区 配置您机器的时区可以让系统自动校正任何区域时间的变更, 并且在执行一些跟时区相关的程序时不会出错。 例子中假设此台机器位于美国东部的时区。 请参考您所在的地理位置来配置。 User Confirmation Requested Would you like to set this machine's time zone now? [ Yes ] No 选择 &gui.yes; 并按下 Enter键以配置时区。 User Confirmation Requested Is this machine's CMOS clock set to UTC? If it is set to local time or you don't know, please choose NO here! Yes [ No ] 这里按照您机器时间的配置,选择 &gui.yes; 或 &gui.no; 然后按 Enter
选择您所处的地理区域
请选择适当的区域然后按 Enter
选择您所在的国家
选择您所在的国家然后按 Enter
选择您所在的时区
选择您所在的时区然后按 Enter Confirmation Does the abbreviation 'EDT' look reasonable? [ Yes ] No 检查一下时区的缩写是否正确,如果没错,请按 Enter 返回系统安装后的配置画面。
Linux 兼容性 User Confirmation Requested Would you like to enable Linux binary compatibility? [ Yes ] No 选择 &gui.yes; 并按下Enter 键, 将允许您在FreeBSD中执行Linux的软件。安装程序会安装一些为了跟 Linux 兼容的软件包。 如果您是通过FTP安装,那么您必须连到网络上。 有时候FTP站并不会包含所有的安装软件包(例如Linux兼容软件包); 不过,稍后您还可以再安装这个项目。 配置鼠标 此选项可以让您在终端上使用三键鼠标剪贴文字。 如果您用的鼠标是两个按钮,请参考手册 &man.moused.8;; 以取得有关模拟三键鼠标的信息。范例中使用的鼠标不是USB接口。 (例如ps/2或com接口的鼠标): User Confirmation Requested Does this system have a PS/2, serial, or bus mouse? [ Yes ] No 如果您使用的是 PS/2、 串口或 Bus 鼠标,请选择 &gui.yes;, 如果是 USB 鼠标, 则应选择 &gui.no; 并按 Enter
选择鼠标类型
使用方向键选择 Type 然后按 Enter
设置鼠标协议
在这个例子中使用的类型是ps/2鼠标,所以可以使用默认的 Auto(自动) 。 您可以用方向键选择合适的项目,确定选择了 &gui.ok; 后按 Enter 键离开此画面。
配置鼠标端口
选择 Port 然后按 Enter
配置鼠标端口
假设这台机器用的是ps/2鼠标,您可以采用默认的 PS/2 选项。请选择适当的项目然后按 Enter
启动鼠标服务进程
选择Enable然后按 Enter 来启动和测试鼠标。
测试鼠标功能
鼠标指针可以在屏幕上移动,指明鼠标服务已经正常启用。那么请选择 &gui.yes; 按 Enter键。否则鼠标没 有配置成功 — 选择 &gui.no; 并尝试不同的配置 选项。 选择 Exit 并按 Enter 退回到系统安装完成后的配置画面。
安装预编译的软件包 (package) Package 是事先编译好的二进制文件, 因此, 这是安装软件的一种便捷的方式。 在这里作为例子我们将给出安装一个 package 所需的过程。 如果需要, 还可以在这一阶段加入其他 package。 安装完成之后, sysinstall 依然可以用来安装其他 package。 User Confirmation Requested The FreeBSD package collection is a collection of hundreds of ready-to-run applications, from text editors to games to WEB servers and more. Would you like to browse the collection now? [ Yes ] No 选择 &gui.yes; 并按 Enter 将进入 package 选择界面:
选择 Package 类别
在任何时候, 只有当前安装介质上存在的 package 才可以安装。 如果选择了 All 或某个特定的分类, 则系统会列出全部可用的 package。 用光标键移动光棒选中需要的 package, 并按 Enter 系统会显示可供选择的 package:
选择 Package
如图所示, 我们选择了 bash shell。 您可以根据需要使用 Space 键来勾选选定的 package。 在屏幕左下角会给出 package 的简短说明。 反复按下 Tab 键, 可以在最后选中的 package、 &gui.ok; 和 &gui.cancel; 之间来回切换。 当您把需要的 package 都标记为安装之后, 按一下 Tab 切换到 &gui.ok;, 随后按下 Enter 就可以回到 package 选择菜单了。 左右方向键可以用于在 &gui.ok; 和 &gui.cancel; 之间进行切换。 这种方法也可以用来选择 &gui.ok;, 随后按下 Enter 也可以回到 package 选择菜单。
安装预编译软件包
使用 Tab 和左右方向键选择 [ Install ] 并按 Enter。 接下来需要确认将要安装的预编译包:
确认将要安装的预编译包
选择 &gui.ok; 并按下 Enter 就可以开始预编译包的安装了。在这个过程中您会看到安装的相关信息, 直到安装完成为止。请留意观察是否有错误信息出现。 在完成预编译包的安装之后, 就进入了最后的配置阶段。 如果您没有选择任何预编译包, 并希望直接进入最后的配置阶段, 则可以选择 Install 来跳过。
添加用户和组 在安装系统的过程中, 您应添加至少一个用户, 以避免直接以 root 用户的身份登录。 用以保存其用户数据的根分区通常很小, 因此用 root 身份运行程序可能将其迅速填满。 下面的提示信息介绍了这样做可能带来的更大隐患: User Confirmation Requested Would you like to add any initial user accounts to the system? Adding at least one account for yourself at this stage is suggested since working as the "root" user is dangerous (it is easy to do things which adversely affect the entire system). [ Yes ] No 选择 &gui.yes; 并按 Enter 即可开始创建用户的过程。
选择用户
用箭头键来选择 User 然后按 Enter
添加用户信息
下面的描述信息会出现在屏幕的下方,可以使用 Tab 键来切换不同的项目,以便输入相关信息: Login ID 新用户的登录名(强制性必须写) UID 这个用户的ID编号(如果不写,系统自动添加) Group 这个用户的登录组名(如果不写,系统自动添加) Password 这个用户的密码(键入这个需要很仔细!) Full name 用户的全名(解释、备注) Member groups 这个用户所在的组 Home directory 用户的主目录(如果不写,系统自动添加) Login shell 用户登录的shell(默认是/bin/sh)。 你可以将登录 shell 由 /bin/sh 改为 /usr/local/bin/bash, 以便使用事先以 package 形式安装的 bash shell。不要使用一个不存在的或您不能登录的shell。 最通用的shell是使用 BSD-world 的 C shell, 可以通过指定/bin/tcsh来修改。 用户也可以被添加到 wheel 组中成了一个超级用户,从而拥有 root 权限。 当您感觉满意时,键入 &gui.ok; 键, 用户和组管理菜单将会重新出现。
退出用户和组管理
如果有其他的需要, 此时还可以添加其他的组。 此外, 还可以通过 sysinstall 在安装完成之后添加它们。 当您完成添加用户的时候,选择Exit 然后键入Enter 继续下面的安装。
设置 <username>root</username> 密码 Message Now you must set the system manager's password. This is the password you'll use to log in as "root". [ OK ] [ Press enter or space ] 键入 Enter 来设置 root 密码。 密码必须正确地输入两次。 毋庸讳言, 您需要选择一个不容易忘记的口令。 请注意您输入的口令不会回显, 也不会显示星号。 New password: Retype new password : 密码成功键入后,安装将继续。 退出安装 如果您需要设置 其他网络设备, 或需要完成其他的配置工作, 可以在此时或者事后通过 sysinstall 来进行配置。 User Confirmation Requested Visit the general configuration menu for a chance to set any last options? Yes [ No ] 选择 &gui.no; 然后键入 Enter 返回到主安装菜单。
退出安装
选择 [X Exit Install] 然后键入 Enter。您可能需要确认是否真的退出安装: User Confirmation Requested Are you sure you wish to exit? The system will reboot (be sure to remove any floppies/CDs/DVDs from the drives). [ Yes ] No 选择 &gui.yes; 取出软盘。CDROM 驱动器将被锁定, 直到机器重新启动。CDROM 解锁后就可以取出光盘了。 此后系统将重新启动, 因此请留意是否会出现一些错误信息。 进一步的细节, 请参见
Tom Rhodes 原作 配置其他网络服务 如果之前缺少这一领域的经验, 那么配置网络服务对于新手而言, 很可能会是一件很有挑战的事情。 网络, 包括 Internet, 对于包括 &os; 在内的所有现代操作系统而言都至关重要。 因此, 首先对 &os; 提供的丰富的网络性能加以了解会很有帮助。 在安装过程中了解这些知识, 能够确保用户更好地理解他们可以用到的各种服务。 网络服务是一些可以接收来自网络上任何地方的人所提交的输入信息的程序。 人们一直都在努力确保这些程序不会做任何 有害的 事情。 不幸的是, 程序员们并不是十全十美的完人,因此,网络服务程序中的漏洞, 便有可能被攻击者利用来做一些坏事。因而, 只启用那些您知道自己需要的服务就很重要了。如果存在疑问, 那么就最好不要在您发现需要它之前启动任何网络服务。 您可以事后通过再次运行 sysinstall 或直接手工配置 /etc/rc.conf 来随时启用这些服务。 选择 Networking 选项将下显示一个类似下面的菜单:
网络配置之上层配置
第一个选项, Interfaces, 已经在前面的 中做过配置, 因此现在可以略过它。 选择 AMD 选项, 将添加对于 BSD 自动挂接程序的支持。 这个程序通常会和 NFS 协议 (详情参见下文) 配合使用,以便自动挂载远程文件系统。 启用它不需要在此时进行特殊的额外配置。 下一行是 AMD Flags 的参数选项。 选择它之后,会弹出一个让您选择 AMD 参数的子菜单。 菜单中包含一系列的选项: -a /.amd_mnt -l syslog /host /etc/amd.map /net /etc/amd.map 选项用来设置默认的挂接位置,这里使用的是 /.amd_mnt目录。 指定默认的 日志 文件; 但是,当使用 syslogd 时,所有在日之中记录的活动, 都会发送到系统日志服务去。 /host 用来挂接远程主机上输出的文件系统,而 /net 目录则用来挂接从特定 IP 地址输出的文件系统。 /etc/amd.map 文件定义了用于 AMD 的默认输出选项。 FTP anonymous (匿名) Anon FTP 允许匿名 FTP 访问。 选中这个选项, 可以使这台机器成为一台匿名 FTP 服务器。 要注意启用这个选项的安全风险。 系统将使用另外的菜单来说明安全风险和进一步的配置。 Gateway 选项可以使将本机配置成为一台以前我们介绍过的网关。 如果您在安装过程中不小心选中了 Gateway, 也可以在这里用这个选项来取消。 Inetd 选项用来配置或完全禁用前面讨论过的 &man.inetd.8; 服务程序。 Mail 用来配置系统默认的 MTA 或邮件传输代理。 选择这个选项将出现下面的菜单:
选择默认的 MTA
这里给您提供了一个安装MTA 并将其配置为默认值的机会。MTA 是一种能够将邮件头递给本系统或互联网上的用户的邮件服务。 选择 Sendmail 将会安装十分流行的 sendmail 服务, 这也是 &os; 的默认配置。Sendmail local 选项表示将 sendmail 设为默认的 MTA,但禁止其从 Internet 上接收邮件的能力。 此外还有一些其他选项,PostfixEximSendmail 的功能类似。 它们两者也可以投递邮件; 不过, 有些用户会喜欢使用它们代替 sendmail MTA 选择 MTA 或决定不挑选 MTA 之后, 网络配置菜单的下一项将是 NFS client NFS client 客户端可以使系统通过 NFS 与服务器进行通信。 NFS 服务器通过 NFS 协议可以使其它在网络上的机器来访问自己的文件系统。 如果这台机器要作为一台独立的服务器,这个选项可以保留不选。 如果启用它, 您在之后还需要进行更多的其他配置; 请参见 以了解关于配置客户机和服务器的进一步详情。 接下来的 NFS server 选项, 可以让您将本机系统配置为 NFS 服务器。 这会自动将启动 RPC 远程过程调用的信息写入配置文件。 RPC 是一种在多个主机和程序之间进行连接组织的机制。 下一项是 Ntpdate 选项, 它能够处理时间同步。 当选择它后, 会出现一个像下面所似的菜单:
Ntpdate 配置
从这个菜单选择一个离您最近的服务器。 选择较近的服务器,有助于提高时间同步的精度, 因为较远的服务器的连接延迟可能会比较大。 下一个选项是 PCNFSD。 这个选项将安装第三方软件包 net/pcnfsd。 它可以用来为无法自行提供 NFS 认证服务的操作系统, 如微软的 &ms-dos; 提供服务。 滚屏到下一页看一下其它选项:
网络配置之下层配置
&man.rpcbind.8;, &man.rpc.statd.8; 和 &man.rpc.lockd.8; 这三个程序是用来提供远程过程调用 (RPC) 服务的。 rpcbind 程序管理 NFS 服务器和客户端的通信, 这是 NFS 正确工作的必要前提。rpc.statd 程序可以和其它主机上 rpc.statd 程序交互, 以提供状态监控。这些状态报告默认情况下会保存到 /var/db/statd.status 文件中。 最后的一项是 rpc.lockd 选项, 如果启用,则将提供文件上锁服务。通常将它和 rpc.statd 联用, 以监视哪些主机会请求对文件执行上锁操作, 以及这种操作的频繁程度。 尽管后两项功能对于调试非常有用, 但它们并不是 NFS 服务器和客户端正常运行所必需的。 下一个项目是Routed,这是一个路由程序。 &man.routed.8; 程序管理网络路由表,发现多播路由, 并且支持在网络上与它物理相连的主机来复制它的路由表的请求。 它被广泛地应用在本地网络中并扮演着网关的角色。 当选择它后,一个子菜单会来询问您这个程序的默认位置。 默认的位置已经被定义过, 您可以选择 Enter 键, 也可以按下其它的键。 这时会出来另一个菜单来询问您传递给 routed程序的参数。 默认的是 参数。 接下来是 Rwhod 选项, 选中它会启用 &man.rwhod.8; 程序在系统初时化的时候。 rwhod程序通过网络周期性的广播系统 信息或以客户的身份来收集这些信息。 更多的信息可以查看 &man.ruptime.1; 和 &man.rwho.1; 手册页。 倒数第二个选项是&man.sshd.8; 程序。它可以通过使用 OpenSSH 来提供安全的shell服务, 我们推荐通过使用它来使用 telnetFTP 服务。 sshd 服务通过使用加密技术来创建从一台机器到另一台机器的安全连接。 最后有一个 TCP 扩展选项。 这可以用来扩展在 RFC 1323 和 RFC 1644 里定义的 TCP 功能。当许多主机以高速连接本机时,可能会引起某些连接被丢弃。 我们不推荐使用这个选项, 但是当使用独立的主机时可以从它上面得到一些好处。 现在您已经配置完成了网络服务, 您可以滚动屏幕到顶部选择 X Exit 项, 退出进入下一个配置部分, 或简单地选择两次 X Exit 之后选择 [X Exit Install] 来退出 sysinstall
&os; 的启动过程 &os;/&arch.i386; 的启动过程 如果启动正常,您将看到在屏幕上有很多信息滚动, 最后您会看到登录命令行。您可以通过键入 Scroll-Lock和使用 PgUpPgDn来查看信息,再键入 Scroll-Lock 回到命令行。 记录信息可能不会显示(缓冲区的限制)。您可以通过键入 dmesg 来查看。 使用您在安装过程中设置的用户名/密码来登录。(例子中使用 rpratt)。除非必须的时候请不要用 root 用户登录。 典型的启动信息:(忽略版本信息) Copyright (c) 1992-2002 The FreeBSD Project. Copyright (c) 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994 The Regents of the University of California. All rights reserved. Timecounter "i8254" frequency 1193182 Hz CPU: AMD-K6(tm) 3D processor (300.68-MHz 586-class CPU) Origin = "AuthenticAMD" Id = 0x580 Stepping = 0 Features=0x8001bf<FPU,VME,DE,PSE,TSC,MSR,MCE,CX8,MMX> AMD Features=0x80000800<SYSCALL,3DNow!> real memory = 268435456 (262144K bytes) config> di sn0 config> di lnc0 config> di le0 config> di ie0 config> di fe0 config> di cs0 config> di bt0 config> di aic0 config> di aha0 config> di adv0 config> q avail memory = 256311296 (250304K bytes) Preloaded elf kernel "kernel" at 0xc0491000. Preloaded userconfig_script "/boot/kernel.conf" at 0xc049109c. md0: Malloc disk Using $PIR table, 4 entries at 0xc00fde60 npx0: <math processor> on motherboard npx0: INT 16 interface pcib0: <Host to PCI bridge> on motherboard pci0: <PCI bus> on pcib0 pcib1: <VIA 82C598MVP (Apollo MVP3) PCI-PCI (AGP) bridge> at device 1.0 on pci0 pci1: <PCI bus> on pcib1 pci1: <Matrox MGA G200 AGP graphics accelerator> at 0.0 irq 11 isab0: <VIA 82C586 PCI-ISA bridge> at device 7.0 on pci0 isa0: <ISA bus> on isab0 atapci0: <VIA 82C586 ATA33 controller> port 0xe000-0xe00f at device 7.1 on pci0 ata0: at 0x1f0 irq 14 on atapci0 ata1: at 0x170 irq 15 on atapci0 uhci0: <VIA 83C572 USB controller> port 0xe400-0xe41f irq 10 at device 7.2 on pci0 usb0: <VIA 83C572 USB controller> on uhci0 usb0: USB revision 1.0 uhub0: VIA UHCI root hub, class 9/0, rev 1.00/1.00, addr 1 uhub0: 2 ports with 2 removable, self powered chip1: <VIA 82C586B ACPI interface> at device 7.3 on pci0 ed0: <NE2000 PCI Ethernet (RealTek 8029)> port 0xe800-0xe81f irq 9 at device 10.0 on pci0 ed0: address 52:54:05:de:73:1b, type NE2000 (16 bit) isa0: too many dependant configs (8) isa0: unexpected small tag 14 fdc0: <NEC 72065B or clone> at port 0x3f0-0x3f5,0x3f7 irq 6 drq 2 on isa0 fdc0: FIFO enabled, 8 bytes threshold fd0: <1440-KB 3.5" drive> on fdc0 drive 0 atkbdc0: <keyboard controller (i8042)> at port 0x60-0x64 on isa0 atkbd0: <AT Keyboard> flags 0x1 irq 1 on atkbdc0 kbd0 at atkbd0 psm0: <PS/2 Mouse> irq 12 on atkbdc0 psm0: model Generic PS/2 mouse, device ID 0 vga0: <Generic ISA VGA> at port 0x3c0-0x3df iomem 0xa0000-0xbffff on isa0 sc0: <System console> at flags 0x1 on isa0 sc0: VGA <16 virtual consoles, flags=0x300> sio0 at port 0x3f8-0x3ff irq 4 flags 0x10 on isa0 sio0: type 16550A sio1 at port 0x2f8-0x2ff irq 3 on isa0 sio1: type 16550A ppc0: <Parallel port> at port 0x378-0x37f irq 7 on isa0 ppc0: SMC-like chipset (ECP/EPP/PS2/NIBBLE) in COMPATIBLE mode ppc0: FIFO with 16/16/15 bytes threshold ppbus0: IEEE1284 device found /NIBBLE Probing for PnP devices on ppbus0: plip0: <PLIP network interface> on ppbus0 lpt0: <Printer> on ppbus0 lpt0: Interrupt-driven port ppi0: <Parallel I/O> on ppbus0 ad0: 8063MB <IBM-DHEA-38451> [16383/16/63] at ata0-master using UDMA33 ad2: 8063MB <IBM-DHEA-38451> [16383/16/63] at ata1-master using UDMA33 acd0: CDROM <DELTA OTC-H101/ST3 F/W by OIPD> at ata0-slave using PIO4 Mounting root from ufs:/dev/ad0s1a swapon: adding /dev/ad0s1b as swap device Automatic boot in progress... /dev/ad0s1a: FILESYSTEM CLEAN; SKIPPING CHECKS /dev/ad0s1a: clean, 48752 free (552 frags, 6025 blocks, 0.9% fragmentation) /dev/ad0s1f: FILESYSTEM CLEAN; SKIPPING CHECKS /dev/ad0s1f: clean, 128997 free (21 frags, 16122 blocks, 0.0% fragmentation) /dev/ad0s1g: FILESYSTEM CLEAN; SKIPPING CHECKS /dev/ad0s1g: clean, 3036299 free (43175 frags, 374073 blocks, 1.3% fragmentation) /dev/ad0s1e: filesystem CLEAN; SKIPPING CHECKS /dev/ad0s1e: clean, 128193 free (17 frags, 16022 blocks, 0.0% fragmentation) Doing initial network setup: hostname. ed0: flags=8843<UP,BROADCAST,RUNNING,SIMPLEX,MULTICAST> mtu 1500 inet 192.168.0.1 netmask 0xffffff00 broadcast 192.168.0.255 inet6 fe80::5054::5ff::fede:731b%ed0 prefixlen 64 tentative scopeid 0x1 ether 52:54:05:de:73:1b lo0: flags=8049<UP,LOOPBACK,RUNNING,MULTICAST> mtu 16384 inet6 fe80::1%lo0 prefixlen 64 scopeid 0x8 inet6 ::1 prefixlen 128 inet 127.0.0.1 netmask 0xff000000 Additional routing options: IP gateway=YES TCP keepalive=YES routing daemons:. additional daemons: syslogd. Doing additional network setup:. Starting final network daemons: creating ssh RSA host key Generating public/private rsa1 key pair. Your identification has been saved in /etc/ssh/ssh_host_key. Your public key has been saved in /etc/ssh/ssh_host_key.pub. The key fingerprint is: cd:76:89:16:69:0e:d0:6e:f8:66:d0:07:26:3c:7e:2d root@k6-2.example.com creating ssh DSA host key Generating public/private dsa key pair. Your identification has been saved in /etc/ssh/ssh_host_dsa_key. Your public key has been saved in /etc/ssh/ssh_host_dsa_key.pub. The key fingerprint is: f9:a1:a9:47:c4:ad:f9:8d:52:b8:b8:ff:8c:ad:2d:e6 root@k6-2.example.com. setting ELF ldconfig path: /usr/lib /usr/lib/compat /usr/X11R6/lib /usr/local/lib a.out ldconfig path: /usr/lib/aout /usr/lib/compat/aout /usr/X11R6/lib/aout starting standard daemons: inetd cron sshd usbd sendmail. Initial rc.i386 initialization:. rc.i386 configuring syscons: blank_time screensaver moused. Additional ABI support: linux. Local package initialization:. Additional TCP options:. FreeBSD/i386 (k6-2.example.com) (ttyv0) login: rpratt Password: 生成 RSA 和 DSA密钥在比较慢的机器上可能要花很长时间。这只是一个 新安装后的首次启动,以后的启动会变得更快一点。 如果已经完成 X 服务器的配置, 且指定了默认的桌面窗口管理器, 就可以在命令行键入 startx 来启动它了。 &os;/&arch.alpha; 的启动过程 Alpha 一旦安装完成,您就可以键入下面的命令来启动FreeBSD: >>>BOOT DKC0 这是从指定的固定硬件进行引导。如果要使 FreeBSD 下次能够自动启动, 使用下面的命令: >>> SET BOOT_OSFLAGS A >>> SET BOOT_FILE '' >>> SET BOOTDEF_DEV DKC0 >>> SET AUTO_ACTION BOOT 启动信息跟启动 &i386;机器时差不多。(但不完全一样) FreeBSD 关机 正确的关闭操作系统是很重要的。不要仅仅关闭电源。 首先,您需要成为一个超级用户,通过键入 su 命令来实现。然后输入 root 密码。这需要用户是 wheel 组的一名成员。然后, 以root键入 shutdown -h now命令。 The operating system has halted. Please press any key to reboot. 当shutdown命令发出后,屏幕上出现 Please press any key to reboot 信息时,您就可以安全的关闭计算机了。如果按下任意一个键, 计算机将重新启动。 您也能够使用 Ctrl Alt Del 组合键来重新启动计算机,但是不推荐使用这个操作。
常见问题 安装 常见问题 下面将介绍一些在安装过程中常见的问题,像如何报告发生的问题, 如何双重启动 FreeBSD 和 &ms-dos; 或 &windows;。 当您遇到错误时,应该怎么做? 由于 PC 结构的限制, 硬件检测不可能 100% 地可靠, 但是有些问题是您可以自己解决的。 首先检查一下您使用的 &os; 版本的 硬件兼容说明 文档看看您使用的是否是被支持的硬件。 如果您使用的硬件是系统支持的,但仍然遇到了死机或其他问题, 则需要联编 定制的内核。 这能够支持默认的 GENERIC 内核所不支持的设备。 在引导盘上的内核假定绝大多数的硬件,均为按出厂设置的方式配置了 IRQ、 IO 地址和 DMA 通道。 如果您的硬件重新进行了配置, 则可能需要编辑内核配置, 并重新编译内核, 以便告诉 &os; 到哪里去查找设备。 除此之外,也可能遇到这种情况吗,即探测某种并不存在的设备时, 会干扰到其他设备的检测并使其失败。 这种情况吗下应禁止驱动程序检测可能导致冲突的设备。 有些安装问题可以借助更新硬件的程序来解决,特别是主板的 BIOS 。 大部分的主板制造商都会提供网站给用户下载新的 BIOS 以及提供如何更新的说明。 也有许多制造商强烈建议,除非必要否则不要轻易更新 BIOS 。因为更新的过程 可能 会发生问题,进而损害 BIOS 芯片。 使用 &ms-dos; 和 &windows; 文件系统 目前, &os; 尚不支持通过 Double Space™ 程序压缩的文件系统。 因此,如果希望 &os; 访问数据, 则应首先解压缩这些文件系统。 这项工作,可以通过位于 Start> Programs > System Tools 菜单的 Compression Agent 来完成。 &os; 可以支持基于 &ms-dos; 的文件系统 (有时被称为 FAT 文件系统)。 &man.mount.msdosfs.8; 命令能够把这样的文件系统挂接到现有的目录结构中, 并允许访问 FAT 文件系统上的内容。 通常我们并不直接使用 &man.mount.msdosfs.8; 程序,它一般会在 /etc/fstab 中的某一行被调用或者被 &man.mount.8; 工具并配合适当的参数来调用。 /etc/fstab中一个典型的例子: /dev/ad0sN /dos msdosfs rw 0 0 /dos 目录必须事先存在。 更多关于 /etc/fstab 的细节, 请参阅 &man.fstab.5;。 一个使用 &man.mount.8; 挂载 &ms-dos; 文件系统的例子: &prompt.root; mount -t msdosfs /dev/ad0s1 /mnt 在此例子中, &ms-dos; 文件系统位于主硬盘的第一个分区。 您的情况可能与引不同,查看命令 dmesgmount 的输出。 它们应该可以让您得到足够的分区信息。 &os; 可能使用和其他操作系统不同计数方法来标记磁盘 slices, 特别需要指出的是, &ms-dos; 的扩展分区通常会比 &ms-dos; 主分区被标记为更高的数值。 可以使用 &man.fdisk.8; 工具来帮助测定哪些 slices 属于 &os; 哪些是属于其他的操作系统。 NTFS 分区也可以通过类似 &man.mount.ntfs.8; 命令挂接在FreeBSD上。 排除故障时的常见问题和解决方法 我的系统在引导到探测硬件时发生了死机、 安装过程中行为异常, 或没有检测到软驱。 &os; 在启动过程中广泛使用了 i386、 amd64 及 ia64 平台提供的 ACPI 服务来检测系统配置。 不幸的是, 在 ACPI 驱动和主板 BIOS 中存在一些 bug。 如果遇到这种情况, 可以在系统引导时禁用 ACPI, 其方法是在第三阶段引导加载器时使用 hint hint.acpi.0.disabled set hint.acpi.0.disabled="1" 这一设置会在系统重启之后失效,因此,如果需要的话,您应在 /boot/loader.conf 文件中增加 hint.acpi.0.disabled="1"。 关于引导加载器的进一步详情, 请参见 在硬盘安装 &os; 之后的首次启动时, 内核加载并检测了硬件, 但给出下列消息并停止运行: changing root device to ad1s1a panic: cannot mount root 这是怎么回事? 我该怎么做? 另外引导帮助信息里提到的 bios_drive:interface(unit,partition)kernel_name 是什么? 系统在处理引导盘非系统中的第一块盘时有一个由来已久的问题。 BIOS 采用的编号方式有时和 &os; 不一致, 而设法将其变为一样则很难正确地实现。 因而, 在发生这种情况时,&os; 可能会需要一些帮助才能找到磁盘。有两种常见的情况, 在这些情况下您都需要手工告诉 &os; 根文件系统模块的位置。 这是通过告诉引导加载器 BIOS 磁盘编号、磁盘类型以及 &os; 中的该种磁盘的编号来实现的。 第一种情况是有两块 IDE 硬盘, 分别配置为对应 IDE 总线上的主 (master) 设备, 并希望 &os; 从第二块硬盘上启动。 BIOS 将两块硬盘识别为磁盘 0 和磁盘 1, 而 &os; 则将其分别叫做 ad0ad2 &os; 位于 BIOS 磁盘 1, 其类型是 ad 而 &os; 磁盘编号则是 2, 因此, 您应输入: 1:ad(2,a)kernel 注意, 如果您的主总线上有从设备, 则这一配置是不必要的 (因为这样配置是错的)。 第二种情况是从 SCSI 磁盘启动,但系统中安装了一个或多个 IDE 硬盘。这时,&os; 磁盘编号会比 BIOS 磁盘编号小。如果您有两块 IDE 硬盘, 以及一块 SCSI 硬盘,则 SCSI 硬盘将会是 BIOS 磁盘 2, 类型为 da 而 &os; 磁盘编号是 0, 因此, 您应输入: 2:da(0,a)kernel 来告诉 &os; 您希望从 BIOS 磁盘 2 引导, 而它是系统中的第一块 SCSI 硬盘。 假如只有一块 IDE 硬盘, 则应以 1: 代替。 一旦您确定了应选用的正确配置, 就可以用标准的文本编辑器把它写到 /boot.config 文件中了。 除非另行指定, &os; 将使用这个文件的内容, 作为对 boot: 提示的默认回应。 在硬盘安装 &os; 之后的首次启动时, Boot Manager 只是给出了 F? 的菜单提示, 但并不继续引导过程。 在您安装 &os; 进行到分区编辑器时所设置的磁盘尺寸信息不对。 请回到分区编辑器并指定正确的磁盘尺寸。 这种情况必须重新安装 &os;。 如果您无法确定在您机器上的正确尺寸信息,可以用一个小技巧: 在磁盘开始的地方安装一个小的 DOS 分区, 并在其后安装 &os;。 安装程序能够看到这个 DOS 分区, 并利用它推测磁盘的尺寸信息, 这通常会有所帮助。 下面的技巧不再推荐使用, 在这里仅供参考:
如果您正准备建立只运行 &os; 的服务器或工作站, 而无需考虑 (之后) 与 DOS、 Linux 或其他操作系统的兼容性, 也可以使用整个硬盘 (分区编辑器中的 A), 选择 &os; 独占整个硬盘每一个扇区的非标准选项。 这会扫除关于磁盘尺寸的一切烦恼, 但会限制您以后运行 &os; 以外的其他操作系统的能力。
系统找到了 &man.ed.4; 网卡, 但总是报设备超时 (device timeout) 错误。 您的网卡可能使用了与 /boot/device.hints 文件中指定的 IRQ 不同的中断请求号。 &man.ed.4; 驱动默认情况下并不支持 配置 (在 DOS 中使用 EZSETUP 配置的值), 但如果您在网卡的 hints 中指定 -1, 便会使用软配置。 您应使用网卡的跳线进行硬配置 (根据需要修改内核设置) 或通过 hint hint.ed.0.irq="-1" 将 IRQ 指定为 -1。 这会告诉内核使用软配置。 另一个可能是您的网卡使用 IRQ 9, 这会与 IRQ 2 共用同一中断请求线, 同时也是导致问题的一个常见原因 (特别是 VGA 卡使用 IRQ 2 的时候!)。 您应尽量避免使用 IRQ 2 或 9。 + + + + + color + contrast + + + 当在 X11 终端中运行 sysinstall + 的时候, 黄色的字体相对于浅灰色的背景变得难以阅读。 + 有没有什么能让这个应用程序提供高对比度的方法? + + + 如果你已经安装了 X11 并且 sysinstall + 在 &man.xterm.1; 或者 &man.rxvt.1; 中默认的颜色使得文字难以辩认, + 可以在你的 ~.Xdefaults 中加入 + XTerm*color7: #c0c0c0 + 获得深灰色的背景。 + +
Valentino Vaschetto Contributed by 高级安装指南 这节主要描述在一些特殊情况下如何安装FreeBSD。 在一个没有显示器或键盘的系统上安装FreeBSD installation headless (serial console) serial console 这种类型的安装叫做 headless install(无头安装), 因您正要安装FreeBSD的机器不是没带显示器,就是没有显卡。 您可能会问那怎么安装? 可以使用一个串行控制台。 串行控制台基本上是使用另外一台机器来充当主显示设备和键盘。 要这样做,只要执行下面的步骤:创建安装软件,请看 一节说明。 按下面的步骤,修改这些软盘用来引导进入一个串行控制台: 通过启动软盘来引导进入一个串行控制台 mount 如果您想用软盘,FreeBSD将进入它通常的安装模式。 我们要把 FreeBSD 引导进入串行控制台,需要这样做, 您必须使用 &man.mount.8;命令在FreeBSD系统上挂接 boot.flp 的那个软盘。 &prompt.root; mount /dev/fd0 /mnt 现在您已经挂上了软盘, 需要进入 /mnt 目录: &prompt.root; cd /mnt 这儿是您必须设置软盘引导进入串行控制台的地方。 您必须制作一个包含 /boot/loader -h 这行的叫做 boot.config 的文件。 所有这些是为了给引导程序一个标记以引导进入串行控制台。 &prompt.root; echo "/boot/loader -h" > boot.config 现在您已经正确配置好了软盘,您必须使用 &man.umount.8; 命令卸下软盘。 &prompt.root; cd / &prompt.root; umount /mnt 现在您可以从软盘驱动器中取出软盘了。 连接您的 Null-modem 线 null modem cable 您现在需要一根 null modem线 来连接两台机器。只要连接两台机器的串口。 普通的串行线是不行的, 您需要使用一根null modem的线, 因为它在一些十字交叉口有金属线。 开始启动安装 现在开始启动安装。把 boot.flp 的那张软盘插入软盘驱动器,然后开启电源。 连接您的无头机器 cu 现在您已经通过&man.cu.1;连接到了那台机器。 &prompt.root; cu -l /dev/cuad0 就这样! 您已经能够通过您的 cu session 对话来控制那台 无头机器了。 它将要求您把 kern1.flp 的那张软盘插入驱动器, 然后它将提示选择使用哪种终端。 只要选择 FreeBSD 的彩色控制台, 然后继续您的安装。 准备您自己的安装介质 为了避免重复 FreeBSD disc 在这里指 FreeBSD CDROM or DVD 那即意味着您要购买或自己制做。 有好几个原因需要您创建自己的FreeBSD安装介质。 这可能是物理介质,如磁带,使用 sysinstall 程序找到的安装文件, FTP 站点或 &ms-dos;分区。 例如: 您有许多机器连接到本地网络,使用一个FreeBSD光盘。 您要使用FreeBSD来创建一个本地FTP站点, 然后使用这个FTP站点来代替连接到Internet。 您有一张 FreeBSD 光盘, FreeBSD 不支持您的 CD/DVD 驱动器, 但 &ms-dos;/&windows; 支持。 您要复制安装文件到一个DOS分区, 然后使用这些文件进行安装。 您要安装的计算机没有 CD/DVD驱动器和网卡,但您可以连接一个 Laplink-style 串口或并口线缆到那台计算机。 您要通过一个磁带机来安装FreeBSD. 创建一张安装光盘 FreeBSD 的每个发行版本都为每一支持的平台提供至少两张 CDROM 映像 (ISO images)。如果您有刻录机, 这些映像文件可以被(burned) 成FreeBSD的安装光盘。 如果没有刻录机,而上网带宽却很便宜,它也是一种很好的安装方式。 下载正确的 ISO 映像文件 每个版本的ISO映像文件都可以从 ftp://ftp.FreeBSD.org/pub/FreeBSD/ISO-IMAGES-架构名/版本 或最近的镜像站点下载。选择合适的 架构版本 目录中包含下面一些映像文件: FreeBSD 6.<replaceable>X</replaceable> 和 7.<replaceable>X</replaceable> ISO 映像文件名和含意 文件名 包含内容 版本-RELEASE-架构-bootonly.iso 引导 FreeBSD 内核并启动安装界面所需的全部数据。 安装文件可以从 FTP 或其他安装源获得。 版本-RELEASE-架构名-disc1.iso 安装 FreeBSD 所需的全部文件, 以及一份用于与 sysinstall 中的 Repair(修复) 机制联用的 现场文件系统 版本-RELEASE-架构名-disc2.iso 尽可能多的第三方软件包。 version-RELEASE-arch-docs.iso &os; 文档。
必须 下载 bootonly ISO 镜像 (如果有的话) 或第一张光盘的镜像之一。 不需要两个都下载, 因为第一张光盘包括了 bootonly ISO 的全部内容。 如果访问 Internet 的价格便宜, 建议使用 bootonly ISO。 这样您可以安装 &os;, 并从网上通过 ports/packages 系统 (参见 ) 根据需要下载和安装第三方软件包。 如果您正打算安装 &os; 并同时选择一些第三方软件包, 则可以下载第一张光盘的镜像文件。 其它的映像盘也是很有用的,但不是必须的, 尤其是在您有高速的网络连接时。
刻录 CDs 您必须把这些映像文件刻录成光盘。 如果您在其它的FreeBSD系统上完成此项工作,请看 得到更多的信息,(特别是 如果您在其它的系统平台上执行,您需要相应的刻录软件。 映像文件使用的是标准的ISO格式,必须被您的刻录软件所支持。
如果有兴趣制作一张定制的 FreeBSD 版本, 请参考 Release Engineering Article
为 FreeBSD 安装盘建立局域网 FTP 站点 installation network FTP FreeBSD 光盘的布局和 FTP 站点相同。 这样, 建立局域网 FTP 站点来用于网络上的其它计算机安装 FreeBSD, 就十分的容易。 在要作为FTP站点的那台FreeBSD机器上, 确定FreeBSD磁盘放入光驱中并将它挂在 /cdrom 目录中。 &prompt.root; mount /cdrom /etc/passwd 文件中建立一个可匿名访问 FTP 服务器的账号。 您可以利用 &man.vipw.8; 命令编辑 /etc/passwd 文件, 加入下面这一行叙述: ftp:*:99:99::0:0:FTP:/cdrom:/nonexistent 确定在 /etc/inetd.conf 配置文件中开启了FTP服务。 任何本地网络中的机器在安装 FreeBSD 选择安装介质时就可以选择透过 FTP 站点,然后选取 Other 后输入 ftp:// 本地FTP服务器 即可以透过本地的FTP站点来安装FreeBSD。 如果用作 FTP 客户端的引导介质 (通常是软盘) 与本地局域网的 FTP 站点上的版本不一致, sysinstall 会不允许您完成安装。 如果您使用的版本差距不很大, 并且希望绕过这一判断, 则应进入 Options 菜单, 并将安装包的名字改为 any 此方式最好使用在有防火墙保护的内部网络。 如果要将此FTP服务公开给外面的网际网络(非本地用户), 您的电脑必须承担被侵入或其它的风险。 我们强烈建议您要有完善的安全机制才这样做。 创建安装软盘 installation floppies 如果您从软盘安装(我们推荐那样做), 或者是由于不支持硬件或者更简单的理由是因为您坚持要使用软盘安装。 您必须准备几张软盘。 至少这些软盘必须是 1.44 MB 的,用来容纳所有在 base (基本系统) 目录下的文件。如果您在 DOS 操作系统下准备就 必须 使用 &ms-dos; 的 FORMAT 命令来格式化软盘。 如果您使用的是 &windows; 操作系统, 在资源管理器中就可以完成这个工作 (用右键单击 A: 驱动器,并选择 Format)。 不要 指望厂家的预先格式化! 最好还是亲自进行格式化。 过去用户报告的很多问题都是由于不正确地使用格式化设备所造成的, 所以我们需要在这里着重提一下。 如果您在另外一台FreeBSD的机器上做了启动盘的话, 进行格式化是一个不错的主意。 虽然您不需要把每张盘都做成DOS文件系统。您也可以使用 bsdlabelnewfs 命令来创建一个UFS文件系统,具体操作按下面的顺序进行: &prompt.root; fdformat -f 1440 fd0.1440 &prompt.root; bsdlabel -w fd0.1440 floppy3 &prompt.root; newfs -t 2 -u 18 -l 1 -i 65536 /dev/fd0 然后您就可以像其它的文件系统一样挂上和写入这些磁盘。 格式化这些磁盘后,您必须把文件复制到磁盘中。 这些发行文件被分割成刚好可存进五张 1.44 MB 软盘。 检查您所有的磁盘, 找出所有可能适合的文件。 直到您找到所有需要的配置并且将它们以这种方式安置。 第一个配置都应该有一个子目录在磁盘上, 例如: a:\base\base.aaa:\base\base.ab, 等等。 base.inf 文件, 也应放在 base 的第一张盘上, 因为安装程序需要读取这个文件, 以了解在获得发布包时需要下载多少文件。 一旦您进入选择安装介质的屏幕, 选择 Floppy 将会看到后面的提示符。 从 &ms-dos; 分区安装 installation from MS-DOS 如果从 &ms-dos; 分区安装, 您需要将发布文件复制到该分区根目录下的 freebsd 目录中。 例如: c:\freebsd。 您必须复制一部分 CDROM 或 FTP 上的目录结构, 因此, 如果您从光盘进行复制, 建议使用 DOS 的 xcopy 命令。 下面是准备进行 FreeBSD 最小系统安装的例子: C:\> md c:\freebsd C:\> xcopy e:\bin c:\freebsd\bin\ /s C:\> xcopy e:\manpages c:\freebsd\manpages\ /s 假设 C: 盘是您的空闲空间, E: 盘是您挂接的 CDROM。 如果您没有光盘驱动器,您可以从以下网站下载发行包。ftp.FreeBSD.org. 每一个发行包都在一个目录中,例如 base 发行包可以在 &rel.current;/base/ 目录中找到。 对很多发行包来说,如果您希望从 &ms-dos;分区安装的话 (您有足够的空间),安装 c:\freebsd — 下的每个文件-这个 BIN 发行包只是最低限度的要求。 创建一个安装磁带 installation from QIC/SCSI Tape 从磁带安装也许是最简单的方式, 比在线使用 FTP 安装或使用 CDROM 还快。安装的程序假设是简单地被压缩在磁带上。 在您得到所有配置文件后,简单地解开它们,用下面的命令: &prompt.root; cd /freebsd/distdir &prompt.root; tar cvf /dev/rwt0 dist1 ... dist2 在您安装的时候,您要确定留有足够的空间给临时目录(允许您选择) 来容纳磁带安装时 全部 的内容。由于不是随机访问 磁带的,所以这种安装方法需要很多临时空间。 开始安装时,在从软盘启动 之前, 磁带机必须已经放在驱动设备中。否则, 安装过程中可能会找不到它。 通过网络安装 installation (安装) network (网络) serial (串口, SLIP 或 PPP) installation (安装) network (网络) parallel (并口, PLIP) installation (安装) network (网络) Ethernet (以太网) 可用的网络安装类型有三种。 以太网 (标准的以太网控制器)、 串口 (SLIP 或 PPP) 以及 并口 (PLIP (laplink 线缆))。 如果希望以最迅速的方式完成网络安装, 那么以太网适配器当然就是首选! FreeBSD 支持绝大多数常见 PC 以太网卡; 系统能够支持的网卡 (以及所需的配置) 可以在 FreeBSD 发行版附带的硬件兼容说明中找到。 如果您使用的是系统支持的 PCMCIA 以太网卡, 在为笔记本加电 之前 之前一定要把它插好! 很不幸, FreeBSD 目前并不支持在安装过程中热插 PCMCIA 卡。 此外, 您还需要知道自己的 IP 地址、 网络类型对应的子网掩码, 以及机器名。 如果您正通过 PPP 连接安装而没有固定的静态 IP, 不用怕, 这个 IP 地址会由您的 ISP 自动分配。 您的系统管理员会告诉您进行网络配置所需的信息。 如果您需要通过名字而不是 IP 地址来访问其他主机, 则还需要配置一个域名服务器, 可能还需要一个网关地址 (在使用 PPP 时, 这个地址是服务提供商的 IP 地址)。 如果您希望通过 HTTP 代理服务器来完成 FTP 安装, 还需要知道代理服务器的地址。 如果您不知道这些信息, 则应在进行这种安装 之前 向系统管理员或 ISP 询问。 SLIP 支持是相当原始的,并且被限制在主要对hard-wired 的连接, 就像一台膝上型计算机与另一台计算机间的串行线。 现在的SLIP的安装还没有提供拨号功能,这个连接应该是 hard-wired; 用PPP工具提供的这种便利性应该首先尽可能被用于 SLIP 设备。 如果您使用一个 MODEM,那您就只有 PPP 这一种选择了。在您安装的过程中, 要确定您能很容易地获得完整且快速的关于您服务提供商的信息。 如果您使用 PAP 或 CHAP 方式连接到您的 ISP, (换句话说,如果您不使用脚本在&windows;中连接到您的ISP), 那么您需要在 ppp 提示符下输入 dial 命令。否则,当 PPP 连接者只提供一种最简单的终端模拟器,您必须知道如何使用针对 MODEM 的 AT commands拨号到您的 ISP。 想知道更深入的信息可以参考 使用手册中的用户级PPP那节 以及 FAQ 。 如果您有一些问题,可以使用 set log local ... 命令将日志显示在屏幕上。 您也可以通过并口电缆连接到另外一台FreeBSD (2.0或以后的版本)机器上进行安装,您可以考虑使用 laplink 并口电缆进行安装。通过并口安装要比通过串口 (最高 50 kbytes/sec)安装快得多。 通过NFS安装之前 installation network NFS NFS 安装方式是非常方便的。只需要简单地将 FreeBSD 文件复制到一台服务器上,然后在安装时选择NFS介质。 如果这个服务器要 特权端口 才能支持 (如SUN的工作站),您需要在安装前在 Options 菜单中设置 NFS Secure 如果你使用了一块低质量的以太网卡比较糟糕, 速度很慢,则应考虑 NFS Slow的选项。 为了达到NFS安装的目的,这个服务器必须支持 subdir 加载。 例如,如果您的 FreeBSD &rel.current; 目录存在: ziggy:/usr/archive/stuff/FreeBSD,然后 ziggy 将必须允许直接挂上 /usr/archive/stuff/FreeBSD,而不仅仅是 /usr/usr/archive/stuff 在 FreeBSD的 /etc/exports 配置文件中, 是由 选项来控制的。其它 NFS 服务器也许有不同的方式。如果您从服务器得到 permission denied 这个信息, 可能是因为您没有正确的启用它。
diff --git a/zh_CN.GB2312/books/handbook/introduction/chapter.sgml b/zh_CN.GB2312/books/handbook/introduction/chapter.sgml index 788f818d2b..5982913295 100644 --- a/zh_CN.GB2312/books/handbook/introduction/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/introduction/chapter.sgml @@ -1,908 +1,924 @@ Jim Mock Restructured, reorganized, and parts rewritten by 介绍 概述 非常感谢您对 &os; 感兴趣! 下面的章节涵盖了 &os; 项目的各个方面, 比如它的历史、目标、开发模式,等等。 阅读完这章,您将了解: &os; 与其它计算机操作系统的关系。 &os; 项目的历史。 &os; 项目的目标。 &os; 开放源代码开发模式的基础。 当然还有:&os; 这个名称的由来。 欢迎来到 &os; 的世界! 4.4BSD-Lite &os; 是一个支持 Intel (x86 和 &itanium;),AMD64,Alpha,Sun &ultrasparc; 计算机的基于 4.4BSD-Lite 的操作系统。 到其他体系结构的移植也在进行中。 您也可以阅读 &os; 的历史, 或者最新的发行版本。 如果您有意捐助(代码, 硬件,基金),请看为 &os; 提供帮助这篇文章。 &os; 能做些什么? &os; 有许多非凡的特性。其中一些是: 抢占式多任务 抢占式多任务与动态优先级调整确保在应用程序和用户之间平滑公正的分享计算机资源, 即使工作在最大的负载之下。 多用户设备 多用户设备 使得许多用户能够同时使用同一 &os; 系统做各种事情。 比如, 像打印机和磁带驱动器这样的系统外设, 可以完全地在系统或者网络上的所有用户之间共享, 可以对用户或者用户组进行个别的资源限制, 以保护临界系统资源不被滥用。 TCP/IP 网络 符合业界标准的强大 TCP/IP 网络 支持, 例如 SCTP、 DHCP、 NFS、 NIS、 PPP, SLIP, IPsec 以及 IPv6。 这意味着您的 &os; 主机可以很容易地和其他系统互联, 也可以作为企业的服务器,提供重要的功能, 比如 NFS(远程文件访问)以及 email 服务, 或将您的组织接入 Internet 并提供 WWW,FTP,路由和防火墙(安全)服务。 内存保护 内存保护确保应用程序(或者用户)不会相互干扰。 一个应用程序崩溃不会以任何方式影响其他程序。 &os; 是一个 32 位操作系统 (在 Alpha,&itanium;,AMD64,和 &ultrasparc; 上是64 位), 并且从开始就是如此设计的。 X Window 系统 XFree86 业界标准的 X Window 系统 (X11R7)为便宜的常见 VGA 显示卡和监视器提供了一个图形化的用户界面(GUI), 并且完全开放代码。 二进制代码兼容性 Linux 二进制代码兼容性 SCO 二进制代码兼容性 SVR4 二进制代码兼容性 BSD/OS 二进制代码兼容性 NetBSD 和许多 Linux,SCO,SVR4,BSDI 和 NetBSD 程序的二进制代码兼容性 数以千计的 ready-to-run 应用程序可以从 &os; portspackages 套件中找到。 您可以顺利地从这里找到, 何须搜索网络? 可以在 Internet 上找到成千上万其它 easy-to-port 的应用程序。 &os; 和大多数流行的商业 &unix; 代码级兼容, 因此大多数应用程序不需要或者只要很少的改动就可以编译。 虚拟内存 页式请求虚拟内存集成的 VM/buffer 缓存设计有效地满足了应用程序巨大的内存需求并依然保持其他用户的交互式响应。 对称多处理器(SMP) SMP 提供对多处理器的支持。 编译器 C 编译器 C++ 编译器 FORTRAN 内建了完整的 CC++Fortran 开发工具。 许多附加的用于高级研究和开发的程序语言, 也可以在通过 ports 和 packages 套件获得。 源代码 完整的系统源代码意味着您对您环境的最大程度的控制。 当您拥有了一个真正的开放系统时, 为什么还要受困于私有的解决方案, 任商业公司摆布呢? 丰富的在线文档 不仅如此! 4.4BSD-Lite 计算机系统研究组(CSRG) U.C. Berkeley &os; 基于加州大学伯克利分校计算机系统研究组 (CSRG) 发布的 4.4BSD-Lite, 继承了 BSD 系统开发的优良传统。 除了 CSRG 优秀的工作之外, &os; 项目花费了非常多的时间来优化调整系统, 使其在真实负载情况下拥有最好的性能和可靠性。 在现今, 许多商业巨人正为给 PC 操作系统增加新功能、 提升和改善其可靠性, 以便在其上展开激烈竞争的同时, &os; 现在 已经能够提供所有这一切了! &os; 可以提供的应用事实上仅局限于您的想象力。 从软件开发到工厂自动化,从存货控制到遥远的人造卫星天线方位控制, 如果商业的 &unix; 产品可以做到, 那么就非常有可能您也可以用 &os; 来做! &os; 也极大地受益于全世界的研究中心和大学开发的数以千计的高质量的应用程序, 这些程序通常只需要很少的花费甚至免费。 可用的商业应用程序, 每天也都在大量地增加。 因为 &os; 自身的源代码是完全公开的, 所以对于特定的应用程序或项目,可以对系统进行最大限度的定制。 这对于大多数主流的商业生产商的操作系统来说几乎是不可能的。 以下是当前人们应用 &os; 的某些程序的例子: Internet 服务: &os; 内建的强大的 TCP/IP 网络使它得以成为各种 Internet 服务的理想平台, 比如: FTP 服务器 FTP 服务器 web 服务器 World Wide Web 服务器(标准的或者安全的 [SSL]) IPv4 and IPv6 路由 防火墙 NAT 防火墙和 NAT(IP 伪装) 网关 电子邮件 email email 电子邮件服务器 USENET USENET 新闻组和电子布告栏系统 还有许多... 使用 &os;, 您可以容易地从便宜的 386 类 PC 起步,并随着您的企业成长,一路升级到带有 RAID 存储的四路 Xeon 服务器。 教育: 您是一名计算机科学或者相关工程领域的学生吗? 学习操作系统,计算机体系结构和网络没有比在 &os; 可提供的体验下动手实践更好的办法了。许多可自由使用的 CAD、数学和图形设计包也使它对于那些主要兴趣是在计算机上完成 其他工作的人非常有帮助。 研究: 有完整的系统源代码,&os; 对于操作系统研究以及其他计算机科学分支都是一个极好的平台。 &os; 可自由获得的本性, 同样可以使处在不同地方的开发团队在开放的论坛上讨论问题、 交流想法与合作开发成为可能, 且不必担心特别的版权协定或者限制。 路由 DNS 服务器 网络:需要一个新的路由器? 一台域名服务器 (DNS)? 一个隔离您的内部网络的防火墙? &os; 可以容易的把丢弃在角落不用的 386 或者 486 PC 变成一台完善的带包过滤能力的高级路由器。 X Window 系统 XFree86 X Window 系统 Accelerated-X X Window 工作站: &os; 是廉价 X 终端的一种绝佳解决方案, 您可以选择使用免费的 X11 服务器。 与 X 终端不同,如果需要的话 &os; 能够在本地直接运行程序, 因而减少了中央服务器的负担。 &os; 甚至能够在 无盘 环境下启动, 这使得终端更为便宜和易于管理。 GNU Compiler Collection 软件开发: 基本的 &os; 系统带有包括著名的 GNU C/C++ 编译器和调试工具在内的一整套开发工具。 &os; 可以通过 CD-ROM、DVD, 以及匿名 FTP 以源代码和二进制方式获得。请查看 了解获取 &os; 的更多细节。 谁在使用 &os;? 用户 运行 &os; 的大型站点 - &os; 已被用来支持 Internet 上一些最大的站点, + &os; 被世界上最大的 IT 公司用作设备和产品的平台, 包括: + + + Apple + + Apple + + + Cisco + + Cisco + + + Juniper + + Juniper + + + NetApp + + NetApp + + + + &os; 也被用来支持 Internet 上一些最大的站点, 包括: Yahoo! Yahoo! + Yandex + + Yandex + + Apache Apache - Blue Mountain Arts + Rambler - Blue Mountain - Arts + Rambler + + + Sina + + Sina Pair Networks Pair Networks Sony Japan Sony Japan Netcraft Netcraft Weathernews Weathernews - Supervalu - - Supervalu - - TELEHOUSE America TELEHOUSE America - Sophos Anti-Virus - - Sophos - Anti-Virus - - - JMA Wired - - JMA Wired - 等等许多。 关于 &os; 项目 下面的章节提供了项目的一些背景信息, 包括简要的历史、项目目标、以及项目开发模式。 Jordan Hubbard Contributed by &os; 的简要历史 386BSD Patchkit Hubbard, Jordan Williams, Nate Grimes, Rod FreeBSD 项目 历史 &os; 项目起源于 1993 年早期, 部分作为 Unofficial 386BSD Patchkit 的副产物,patchkit 的最后 3 个协调维护人是:Nate Williams,Rod Grimes 和我。 386BSD 我们最初的目标是做出一份 386BSD 的测试版以修正一些 Patchkit 机制无法解决的错误(bug)。 很多人可能还记得早期的项目名称叫做 386BSD 0.5 或者 386BSD Interim 就是这个原因。 Jolitz, Bill 386BSD 是 Bill Jolitz 的操作系统, 到那时已被严重地忽视了一年之久。 由于 Patchkit 在过去的每一天里都在急剧膨胀, 使得对其进行消化吸收变得越来越困难, 因此我们一致同意应该做些事情并决定通过提供这个临时的 cleanup 版本来帮助 Bill。 然而,Bill 却在事先没有指出这个项目应该如何开展下去的情况下, 突然决定退出这个项目,最终这个计划只好被迫停止。 Greenman, David Walnut Creek CDROM 没过多久, 我们认为即便没有 Bill 的支持, 项目仍有保留的价值, 因此,我们采用了 David Greenman 的意见,给其命名为 &os;。在和当时的几个用户商量后, 我们提出了最初的目标, 而这件事明朗化后, 这个项目就走上了正轨,甚至可能成为现实。 为了拓展 &os; 的发行渠道,我抱着试试看的心态, 联系了光盘商 Walnut Creek CDROM, 以便那些上网不方便的用户得到 &os;。 Walnut Creek CDROM 不仅支持发行 &os; 光盘版的想法, 还为这个计划提供了所需的计算机和高速网络接入。 在那时, 若没有 Walnut Creek CDROM 对一个完全未知的项目的空前信任, &os; 不太可能像它今天这样,影响如此深远, 发展如此快速。 4.3BSD-Lite Net/2 U.C. Berkeley 386BSD Free Software Foundation 第一个 CD-ROM (以及在整个互联网范围内发行的) 发行版本是 &os; 1.0,于 1993 年 10 月发布。这个版本基于 U.C. Berkeley 的 4.3BSD-Lite(Net/2)磁带, 也有许多组件是 386BSD 和自由软件基金会提供的。 对于第一次发行,这算是相当成功了。 在 1994 年 5 月,我们发布了更加成功的 &os; 1.1 版。 Novell U.C. Berkeley Net/2 AT&T 然而此后不久,发生了一些意外的情况。 Novell 和 U.C. Berkeley 决定就 Berkeley Net/2 磁带的归属权问题打的那场马拉松式的官司达成和解。 判决的结果是, U.C. Berkeley 承认 Net/2 很大一部分代码是 侵占来的 且这些代码归 Novell 公司所拥有。这些代码是 Novell 不久前从 AT&T 买来的。 Berkeley 得到了来自 Novell 的 祝福: 4.4BSD-Lite 发行后,将不认为是侵权, 且要求现存的 Net/2 的用户更换新版。 这也包括 &os;,我们的项目被要求在 1994 年 6 月底停止发行基于 Net/2 的产品。在此协议允许的时间内, 本项目被允许发行最后一版,也就是 &os; 1.1.5.1。 于是 &os; 开始艰苦的从全新的而且不完整的 4.4BSD-Lite 中重新整合自己。Lite 版本是不完整的, 因为 Berkeley 的 CSRG 已经删除了大量的构建可启动运行的系统所需要的代码 (因为各种各样的版权问题),事实上 4.4 的 Intel port 是非常不完整的。 直到 1994 年 11 月项目才完成这个转换,这个时候才把 &os; 2.0 通过网络和 CD-ROM(在 12 月)发布出来。 尽管系统很多地方还很粗糙,这个版本还是取得了重大的成功, 接下来在 1995 年 6 月发布了更强大和容易安装的 &os; 2.0.5 版本。 我们于 1996 年 8 月发布了 &os; 2.1.5 版本, 它在 ISP 和商业团体中非常流行。 随后, 2.1-STABLE 分支的另一个版本应运而生,它就是 &os; 2.1.7.1,在 1997 年 2 月发布并停止了 2.1-STABLE 的主流开发。现在,它处于维护状态, 仅仅提供安全性的增强和其他严重的错误修补的维护(RELENG_2_1_0)。 &os; 2.2 版作为 RELENG_2_2 分支,于 1996 年 11 月从开发主线 (-CURRENT)分出来。 它的第一个完整版(2.2.1)于 1997 年 4 月发布出来。 97 年夏秋之间,顺着 2.2 分支的更进一步的版本在开发。 其最后一版(2.2.8)于 1998 年 11 月发布出来。 第一个官方的 3.0 版本出现在 1998 年 10 月, 意味着 2.2 分支结束的开始。 1999 年 1 月 20 日又出现了新的分支,就是 4.0-CURRENT 和 3.X-STABLE 分支。从 3.X-STABLE 起,3.1 在 1999 年 2 月 15 日发行,3.2 在1999 年 5 月 15 日,3.3 在 1999 年 9 月 16 日,3.4 在 1999 年 12 月 20 日,3.5 在 2000 年 6 月 24 日,接下来几天后发布了很少的修补升级至 3.5.1,加入了对 Kerberos 安全性方面的修补。 这是 3.X 分支最后一个发行版本。 随后在 2000 年 3 月 13 日出现了一个新的分支, 也就是 4.X-STABLE。 这之后发布了许多的发行版本: 4.0-RELEASE 于 2000 年 3月发布, 而最后的 4.11-RELEASE 则是在 2005 年 1 月发布的。 期待已久的 5.0-RELEASE 于 2003 年 1 月 19 日正式发布。 这是将近三年的开发的巅峰之作, 同时也标志了 FreeBSD 在先进的多处理器和应用程序线程支持的巨大成就, 并引入了对于 &ultrasparc; 和 ia64 平台的支持。 之后于 2003 年 6 月发布了 5.1。 最后一个从 -CURRENT 分支的 5.X 版本是 5.2.1-RELEASE, 它在 2004 年 2 月正式发布。 RELENG_5 于 2004 年 8 月正式创建, 紧随其后的是 5.3-RELEASE, 它是 5-STABLE 分支的标志性发行版。 最新的 5.5-RELEASE 是在 &rel2.current.date; 发布的。 RELENG_5 分支不会有后续的发行版了。 其后在 2005 年 7 月又建立了 RELENG_6 分支。 而 6.X 分支上的第一个版本, 即 6.0-RELEASE, 则是在 2005 年 11 月发布的。 最新的 &rel2.current;-RELEASE 发布于 &rel2.current.date;。 我们还将继续从 RELENG_6 发布新的版本。 RELENG_7 分支于 2007 年 10 月创建。 这个分支最新的发布版本是 &rel.current.date; 的 &rel.current;-RELEASE。 RELENG_7 分支将会有其他后继发布版本。 目前, 中长期的开发项目继续在 8.X-CURRENT (主干, trunk) 分支中进行, 而 8.X 的 CD-ROM (当然, 也包括网络) 快照版本可以在 快照服务器 找到。 Jordan Hubbard Contributed by &os; 项目目标 FreeBSD Project goals &os; 项目的目标是无附加条件地提供能够用于任何目的的软件。 我们中的许多人对代码 (以及项目本身) 都有非常大的投入, 因此当然不介意偶尔有一些资金上的补偿, 但我们并没打算坚决地要求得到这类资助。 我们认为我们的首要 使命 是为任何人提供代码, 不管他们打算用这些代码做什么, 因为这样代码将能够被更广泛地使用, 从而最大限度地发挥其价值。 我认为这是自由软件最基本的, 同时也是为我们所倡导的一个目标。 GNU General Public License (GPL) GNU Lesser General Public License (LGPL) BSD Copyright 我们源代码树中, 以 GNU 公共许可证 (GPL) 或者 GNU 函数库公共许可证 (LGPL) 发布的那些代码带有少许的附加限制, 还好只是强制性的要求开放代码而不是别的。 由于使用 GPL 的软件在商业用途上会增加若干复杂性, 因此,如果可以选择的话, 我们更偏好使用限制相对更宽松的 BSD 版权来发布软件。 Satoshi Asami 撰写者 &os; 开发模式 FreeBSD Project 开发模式 &os; 的开发是一个非常开放且有有伸缩性的过程, 就像从我们的 贡献者列表里看到的,它是完全由来自全世界的数以百计的贡献者发展起来的。 &os; 的开发基础结构允许数以百计的开发者通过互联网协同工作。 我们也经常关注着那些对我们的计划感兴趣的新开发者和新的创意, 那些有兴趣更进一步参与项目的人只需要在 &a.hackers; 联系我们。 &a.announce; 对那些希望了解我们工作所涉及到哪些领域的人也是有用的。 无论是独立地工作或者封闭式的团队工作, 了解 &os; 计划和它的开发过程都是有益的: SVN 和 CVS 代码库 CVS 代码库 并行版本系统 CVS SVN 代码库 Subversion SVN 在过去的几年中 &os; 的中央源代码树是由 CVS (并行版本控制系统)来维护的,CVS 是一个与 &os; 捆绑的可自由获得的源代码控制工具。自 2008 年六月起, 这个项目开始转为使用SVN (Subversion)。 这次转换被认为是非常必要的,因为 CVS 的对于快速扩展源代码树和历史记录的限制越趋明显。现在主源码库使用 SVN,客户端的工具像 CVSupcsup 这些依赖于旧的 CVS 基础结构依然可以使用 — 因为对于 SVN 源码库的修改会被导回进 CVS。 目前只有中央原代码树是由 SVN 控制的。文档,万维网和 Ports 库还仍旧使用着 CVS。 The primary repository resides on a machine in Santa Clara CA, USA 主 CVS 代码库放置在美国加利福尼亚州圣克拉拉的一台机器上, 它被复制到全世界的大量镜像站上。包含 -CURRENT 和 -STABLE 的 SVN 树也同样能非常容易的你的机器上。 请参阅 同步你的源码树 获得更多的相关信息。 committer 列表 committers committer 是那些对 CVS 树有权限的人, 他们被授权修改 &os; 的源代码 (术语 committer 来自于 &man.cvs.1; 的 commit 命令,这个命令用来把新的修改提交给 CVS 代码库)。提交修正的最好方法是使用 &man.send-pr.1; 命令。如果您发现在系统中出现了一些问题的话, 您也可以通过邮件将它们发送至 &a.committers;。 FreeBSD 核心团队 core team 如果把 &os; 项目看作一家公司,那么 &os; 核心团队就相当于董事会。 核心团队的主要任务是提出总体上的发展计划,然后确定一个正确的方向。 邀请那些富有献身精神和可靠的开发者加入到 committer 队伍中来也是核心团队的工作之一, 这些新的成员将作为新核心团队成员和其他人一起继续前进。 当前的核心团队是 2006 年 7 月从 committer 中选举产生的。选举每两年一次。 一些核心团队的成员还负责特定的责任范围, 也就是说他们必须尽力确保某个子系统能工作正常。 &os; 开发者的完整列表和他们的责任范围,请参见 贡献者列表 核心团队的大部分成员加入 &os; 开发的时候都是志愿的, 并没有从项目中获得任何财政上的资助, 所以承诺不应该被理解为支持保证。 前面所述董事会的类推并不十分准确, 或许更好的说法是,他们是一群愿意放弃他们的生活, 投身于 &os; 项目而非选择其个人更好的生活的人! 外围贡献者 contributors 事实上,最大的开发团队正是为我们提供反馈和错误修补的用户自己。 &os; 的非集中式的开发者保持联系的主要方式就是预订 &a.hackers;,很多事情在那里讨论。查看了解众多 &os; 邮件列表的更多信息。 &os; 贡献者列表 很长并在不断增长, 为什么不加入它来为 FreeBSD 做贡献呢? 提供代码不是为这个计划做贡献的唯一方式; 有一个更完整的需要做的事情的列表,可以参见 &os; 项目网站 总的来说,我们的开发模式好像是一组没有拘束的同心圆。 这种集中式的开发模式,主要是考虑到 &os; 用户的方便, 同时让他们能很容易地维护同一份软件, 而不会把潜在的贡献者排除在外! 我们的目标是提供一个包含有大量具有一致性 应用程序的稳定的操作系统, 以利于用户的安装和使用,— 这种模式在完成目标的过程中工作得非常有效。 我们对于那些想要加入,成为 &os; 开发者的期待是: 具有如同当前其他人一样的投入,来确保持续的成功! 最新的 &os; 发行版本 NetBSD OpenBSD 386BSD Free Software Foundation U.C. Berkeley Computer Systems Research Group (CSRG) &os; 是一个免费使用且带有完整源代码的基于 4.4BSD-Lite 的系统, 它广泛运行于 Intel &i386;、&i486;、&pentium;、 &pentium; Pro、 &celeron;、 &pentium; II、 &pentium; III、 &pentium; 4(或者兼容系统)、 &xeon;、DEC Alpha 和 Sun &ultrasparc; 的计算机系统上。 它主要以 加州大学伯克利分校 的 CSRG 研究小组的软件为基础,并加入了 NetBSD、OpenBSD、386BSD 以及来自 自由软件基金会 的一些东西。 自从 1994 年末我们的 &os; 2.0 发行以来, &os; 的性能,可定制性,稳定性都有了令人注目的提高。 最大的变化是通过整合虚拟内存/文件系统中的高速缓存改进的虚拟内存系统, 它不仅提升了性能,而且减少了 &os; 对内存的需要, 使得 5 MB 内存成为可接受的最小配置。 其他的改进包括完整的 NIS 客户端和服务器端的支持, 事务式 TCP 协议支持,按需拨号的 PPP,集成的 DHCP 支持,改进的 SCSI 子系统, ISDN 的支持,ATM,FDDI,快速 Gigabit 以太网(1000 Mbit)支持, 提升了最新的 Adaptec 控制器的支持和修补了很多的错误。 除了最基本的系统软件,&os; 还提供了一个拥有成千上万广受欢迎的程序组成的软件的 Ports Collection。 到本书付印时,已有超过 &os.numports; 个 ports (ports 包括从 http(WWW) 服务器到游戏、程序设计语言、编辑器以及您能想到的几乎所有的东西)。 完整的 Ports Collection 大约需要 &ports.size; 的存储空间。所有的只提供对原始代码的 修正。这使得我们能够容易地更新软件, 而且减少了老旧的 1.0 Ports Collection 对硬盘空间的浪费。 要编译一个 port,您只要切换到您想要安装的程序的目录, 输入 make install,然后让系统去做剩下的事情。 您要编译的每一个程序完整的原始代码可以从 CD-ROM 或本地 FTP 获得,所以您只需要编译您想要软件的足够的磁盘空间。 几乎大多数的软件都提供了事先编译好的 package 以方便安装,对于那些不希望从源代码编译他们自己的 ports 的人只要使用一个简单的命令 (pkg_add)就可以安装。 有关 package 和 ports 的更多信息可以在中找到。 您可以在最近的 &os; 主机的 /usr/share/doc 目录下找到许多有用的文件来帮助您安装及使用 &os;。 您也可以用一个 HTML 浏览器来查阅本地安装的手册, 使用下面的 URL: FreeBSD 使用手册 /usr/share/doc/handbook/index.html FreeBSD FAQ /usr/share/doc/faq/index.html 您也可以查看在 的主站上的副本。 diff --git a/zh_CN.GB2312/books/handbook/kernelconfig/chapter.sgml b/zh_CN.GB2312/books/handbook/kernelconfig/chapter.sgml index 63dfe60b0d..c69fa3cc7e 100644 --- a/zh_CN.GB2312/books/handbook/kernelconfig/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/kernelconfig/chapter.sgml @@ -1,1359 +1,1354 @@ Jim Mock Updated and restructured by Jake Hamby Originally contributed by 配置FreeBSD的内核 概述 内核 建立一个定制的内核 内核是 &os; 操作系统的核心。 它负责管理内存、 执行安全控制、 网络、 磁盘访问等等。 尽管 &os; 可以动态修改的现在已经越来越多, 但有时您还是需要重新配置和编译您的内核。 读完这章,您将了解: 为什么需要建立定制的内核。 如何编写内核配置文件,或修改已存在的配置文件。 如何使用内核配置文件创建和联编新的内核。 如何安装新内核。 如何处理出现的问题。 这一章给出的命令应该以 root 身份执行, 否则可能会不成功。 为什么需要建立定制的内核? 过去, &os; 采用称作 单片式 的内核。 这句话的意思是说内核是一个大的程序, 支持固定的设备, 如果您希望改变内核的行为则必须编译一个新的, 并重新启动计算机来引导它。 今天, &os; 已经迅速地转移到了一个新的模型, 其重要特征是内核功能可以由能够根据需要动态加载和卸载的模块来提供。 这使得内核能够迅速地适应硬件的调整 (例如笔记本电脑的 PCMCIA), 或为内核增加在最初编译它时所不具备的新的功能。 这一模式成为模块化内核。 尽管如此, 一些功能仍然需要静态地连编进内核。 一些情况是因为这些功能于内核的结合十分紧密, 而不可能将它们做成可以动态加载的。 另一种情况是因为没有人有时间来编写实现那个功能的可以动态加载的内核模块。 建造定制的内核是几乎每一个 BSD 用户所必须经历的一关。 尽管这项工作可能比较耗时, 但它能够为使用 &os; 系统带来很多好处。 与必须支持大量各式硬件的 GENERIC 内核不同, 定制的内核可以只包含对于 您的 PC 硬件的支持。 这有很多好处, 例如: 更快地启动。 因为内核只需要检测您系统上的硬件, 启动时所花费的时间将大大缩短。 使用更少的内存。 定制的内核通常会比 GENERIC 内核使用更少的内存, 由于内核必须时刻处于物理内存中, 因此这就显得更加重要。 基于这样的原因, 对于内存较小的系统来说, 定制内核将发挥更大的作用。 支持更多的硬件。 定制的内核允许您增加类似声卡这样的 GENERIC 内核没有提供内建支持的硬件。 Tom Rhodes 作者 发现系统硬件 在尝试配置内核以前,比较明智的做法是先获得一份机器硬件的清单。 当 &os; 并不是主操作系统时,通过查看当前操作系统的配置可以很容易的 创建一份机器硬件的配置清单。举例来说, µsoft; 的 设备管理器 里通常含有关于已安装硬件的重要信息。 设备管理器 位于控制面板。 某些版本的 µsoft.windows; 有一个 系统 图标会指明 设备管理器 的位置。 如果机器上并不存在其他的操作系统, 系统管理员只能手动寻找这些信息了。其中的一个方法是使用 &man.dmesg.8; 工具以及 &man.man.1; 命令。&os; 上大多数的驱动程序都有一份手册页(manual page)列出了所支持的硬件, 在系统启动的时候,被发现的硬件也会被列出。举例来说, 下面的这几行表示 psm 驱动找到了一个鼠标: psm0: <PS/2 Mouse> irq 12 on atkbdc0 psm0: [GIANT-LOCKED] psm0: [ITHREAD] psm0: model Generic PS/2 mouse, device ID 0 这个驱动需要被包含在客户制定的内核配置文件里, 或着使用 &man.loader.conf.5; 加载。 有时,dmesg 里只会显示来自系统消息的数据, 而不是系统启动时的检测信息。在这样的情况下,你可以查看文件 /var/run/dmesg.boot 另一个查找硬件信息的方法是使用 &man.pciconf.8; 工具, 它能提供更详细的输出,比如: ath0@pci0:3:0:0: class=0x020000 card=0x058a1014 chip=0x1014168c rev=0x01 hdr=0x00 vendor = 'Atheros Communications Inc.' device = 'AR5212 Atheros AR5212 802.11abg wireless' class = network subclass = ethernet 这个片断取自于 pciconf 命令的输出,显示 ath 驱动找到了一个无线以太网设备。输入命令 man ath 就能查阅有关 &man.ath.4; 的手册页(manual page)了。 还可以传给 &man.man.1; 命令 选项, 同样能获得有用的信息。例如: &prompt.root; man -k Atheros 能得到一份包含特定词语的手册页(manual page): ath(4) - Atheros IEEE 802.11 wireless network driver ath_hal(4) - Atheros Hardware Access Layer (HAL) 手头备有一份硬件的配置清单, 那么编译制定内核的过程就显得不那么困难了。 内核驱动,子系统和模块 kernel drivers / modules / subsystems 在编译一个制定的内核之前请三思一下这么做的理由, 如果仅是需要某个特定的硬件支持的话, 那么很可能已经存在一个现成的模块了。 内核模块存放在目录 /boot/kernel 中,并能由 &man.kldload.8; 命令加载入正在运行的内核。 基本上所有的内核驱动都有特定的模块和手册页。比如, 下面提到的 ath 无线以太网驱动。 在这个设备的手册页中有以下信息: Alternatively, to load the driver as a module at boot time, place the - following line in &man.loader.conf.5: +following line in &man.loader.conf.5: - if_ath_load="YES" + if_ath_load="YES" 遵照示例,在 /boot/loader.conf 中加入 if_ath_load="YES" 则能在机器启动的时候动态加载这个模块。 某些情况下,则没有相关的模块。通常是一些子系统和非常重要的驱动, 比如,快速文件系统 (FFS) 就是一个内核必需的选项。 同样的还有网络支持 (INET)。不幸的是, 分辨一个驱动是否必需的唯一方法就是检查测试以下那个模块本身。 去除某个驱动的支持或某个选项会非常容易得到一个坏掉的内核。 举例来说,如果把 &man.ata.4; 驱动从内核配置文件中去掉, 那么一个使用 ATA 磁盘设备的系统可能就变得无法引导,除非有在 loader.conf 中加载。当你无法确定的时候, 请检查一下那个模块并把它留在你的内核配置中。 建立并安装一个定制的内核 内核 建立/安装 首先对内核构建目录做一个快速的浏览。 这里所提到的所有目录都在 /usr/src/sys 目录中; 也可以通过 /sys 来访问它。 这里的众多子目录包含了内核的不同部分, 但对我们所要完成的任务最重要的目录是 arch/conf, 您将在这里编辑定制的内核配置; 以及 compile, 编译过程中的文件将放置在这里。 arch 表示 i386alphaamd64ia64powerpcsparc64, 或 pc98 (在日本比较流行的另一种 PC 硬件开发分支)。 在特定硬件架构目录中的文件只和特定的硬件有关; 而其余代码则是与机器无关的, 则所有已经或将要移植并运行 &os; 的平台上都共享这些代码。 文件目录是按照逻辑组织的, 所支持的硬件设备、 文件系统, 以及可选的组件通常都在它们自己的目录中。 这一章提供的例子假定您使用 i386 架构的计算机。 如果您的情况不是这样, 只需对目录名作相应的调整即可。 如果您的系统中 没有 /usr/src/sys 这样一个目录, 则说明没有安装内核源代码。 安装它最简单的方法是通过以 root 身份运行 sysinstall, 选择 Configure, 然后是 Distributionssrc, 选中其中的 basesys。 如果您不喜欢 sysinstall 并且有一张 官方的 &os; CDROM, 也可以使用下列命令, 从命令行来安装源代码: &prompt.root; mount /cdrom &prompt.root; mkdir -p /usr/src/sys &prompt.root; ln -s /usr/src/sys /sys &prompt.root; cat /cdrom/src/ssys.[a-d]* | tar -xzvf - &prompt.root; cat /cdrom/src/sbase.[a-d]* | tar -xzvf - 接下来, 进入 arch/conf 目录下面, 复制 GENERIC 配置文件, 并给这个文件起一个容易辨认的名称, 它就是您的内核名称。例如: &prompt.root; cd /usr/src/sys/i386/conf &prompt.root; cp GENERIC MYKERNEL 通常,这个名称是大写的,如果您正维护着多台不同硬件的&os;机器, 以您机器的域名来命名是非常好的主意。我们把它命名为 MYKERNEL就是这个原因。 将您的内核配置文件直接保存在 /usr/src 可能不是一个好主意。 如果您遇到问题, 删掉 /usr/src 并重新开始很可能是一个诱人的选择。 一旦开始做这件事, 您可能几秒钟之后才会意识到您同时会删除定制的内核配置文件。 另外, 也不要直接编辑 GENERIC, 因为下次您 - 更新代码 时它会被覆盖, + 更新代码 时它会被覆盖, 而您的修改也就随之丢失了。 您也可以考虑把内核配置文件放到别的地方, 然后再到 i386 目录中创建一个指向它的符号链接。 例如: &prompt.root; cd /usr/src/sys/i386/conf &prompt.root; mkdir /root/kernels &prompt.root; cp GENERIC /root/kernels/MYKERNEL &prompt.root; ln -s /root/kernels/MYKERNEL 必须以 root 身份执行这些和接下来命令, 否则就会得到 permission denied 的错误提示。 现在就可以用您喜欢的文本编辑器来编辑 MYKERNEL 了。 如果您刚刚开始使用 FreeBSD, 唯一可用的编辑器很可能是 vi, 它的使用比较复杂, 限于篇幅, 这里不予介绍, 您可以在 参考书目 一章中找到很多相关书籍。 不过, &os; 也提供了一个更好用的编辑器, 它叫做 ee, 对于新手来说, 这很可能是一个不错的选择。 您可以修改配置文件中的注释以反映您的配置, 或其他与 GENERIC 不同的地方。 SunOS 如果您在&sunos;或者其他BSD系统下定制过内核,那这个文件中的绝大部分将对您非常熟悉。 如果您使用的是诸如DOS这样的系统,那GENERIC配置文件看起来就非常困难, 所以在下面的 配置文件章节将慢慢地、仔细地进行介绍。 如果您和 &os; project 进行了 代码同步, + linkend="updating-upgrading">代码同步, 则一定要在进行任何更新之前查看 /usr/src/UPDATING。 这个文件中描述了更新过的代码中出现的重大问题或需要注意的地方。 /usr/src/UPDATING 总是和您的 &os; 源代码对应, 因此能够提供比手册更具时效性的新内容。 现在应该编译内核的源代码了。 联编内核 进入 /usr/src 目录: &prompt.root; cd /usr/src 编译内核: &prompt.root; make buildkernel KERNCONF=MYKERNEL 安装新内核: &prompt.root; make installkernel KERNCONF=MYKERNEL 使用这种方法联编内核时, 需要安装完整的 &os; 源代码。 默认情况下, 在联编您所定制的内核时, 全部 内核模块也会同时参与构建。 如果您希望更快地升级内核, 或者只希望联编您所需要的模块, 则应在联编之前编辑 /etc/make.conf MODULES_OVERRIDE = linux acpi sound/sound sound/driver/ds1 ntfs 这个变量的内容是所希望构建的模块列表。 WITHOUT_MODULES = linux acpi sound/sound sound/driver/ds1 ntfs 这个变量的内容是在联编过程中将不被编译的模块列表。 如果希望了解更多与构建内核有关的变量, 请参见 &man.make.conf.5; 联机手册。 /boot/kernel.old 新内核将会被复制到 /boot/kernel 目录中成为 /boot/kernel/kernel 而旧的则被移到 /boot/kernel.old/kernel。 现在关闭系统, 然后用新的内核启动计算机。 如果出现问题, 后面的一些 故障排除方法 将帮您摆脱困境。 如果您的内核 无法启动, 请参考那一节。 其他与启动过程相关的文件, 如 &man.loader.8; 及其配置, 则放在 /boot。 第三方或定制的模块也可以放在 /boot/kernel, 不过应该注意保持模块和内核的同步时很重要的, 否则会导致不稳定和错误。 Joel Dahl Updated for &os; 6.X by 配置文件 内核 NOTES NOTES 内核 配置文件 配置文件的格式是非常简单的。 每一行都包括一个关键词, 以及一个或多个参数。 实际上, 绝大多数行都只包括一个参数。 在 # 之后的内容会被认为是注释而忽略掉。 接下来几节, 将以 GENERIC 中的顺序介绍所有关键字。 如果需要与平台有关的选项和设备的详细列表, 请参考与 GENERIC 文件在同一个目录中的那个 NOTES, 而平台无关的选项, 则可以在 /usr/src/sys/conf/NOTES 找到。 如果您需要一份包含所有选项的文件, 例如用于测试目的, 则应以 root 身份执行下列命令: &prompt.root; cd /usr/src/sys/i386/conf && make LINT 内核 配置文件 下面是一个 GENERIC 内核配置文件的例子, 它包括了一些需要解释的注释。 这个例子应该和您复制的 /usr/src/sys/i386/conf/GENERIC 非常接近。 内核选项 机器 machine i386 这是机器的架构, 他只能是 alpha, amd64, i386, ia64, pc98, powerpc, 或 sparc64 中的一种。 内核选项 cpu cpu I486_CPU cpu I586_CPU cpu I686_CPU 上面的选项指定了您系统中所使用的 CPU 类型。 您可以使用多个 CPU 类型 (例如, 您不确定是应该指定 I586_CPUI686_CPU)。 然而对于定制的内核, 最好能够只指定您使用的那种 CPU。 如果您对于自己使用的 CPU 类型没有把握, 可以通过查看 /var/run/dmesg.boot 中的启动信息来了解。 内核选项 ident ident GENERIC 这是内核的名字。 您应该取一个自己的名字, 例如取名叫 MYKERNEL, 如果您一直在按照前面的说明做的话。 您放在 ident 后面的字符串在启动内核时会显示出来, 因此如果希望能够容易区分常用的内核和刚刚定制的内核, 就应该采取不同的名字 (例如, 您想定制一个试验性的内核)。 #To statically compile in device wiring instead of /boot/device.hints #hints "GENERIC.hints" # Default places to look for devices. &man.device.hints.5; 可以用来配置设备驱动选项。 在启动的时候 &man.loader.8; 将会检查缺省位置 /boot/devicehints。 使用 hints 选项您就可以把这些 hints 静态编译进内核。 这样就没有必要在 /boot下创建devicehints makeoptions DEBUG=-g # Build kernel with gdb(1) debug symbols 一般的 &os; 联编过程, 在所联编的内核指定了 选项时, 由于此选项将传递给 &man.gcc.1; 表示加入调试信息, 因此会将调试符号也包含进来。 options SCHED_4BSD # 4BSD scheduler 这是 &os; 传统上使用的默认系统调度器。 请保留此选项。 options PREEMPTION # Enable kernel thread preemption 允许内核线程根据优先级的抢占调度。 这有助于改善交互性, 并可以让中断线程更早地执行, 而无须等待。 options INET # InterNETworking 网络支持,即使您不打算连网,也请保留它,大部分的程序至少需要回环网络(就是和本机进行网络连接),所以强烈要求保留它。 options INET6 # IPv6 communications protocols 这将打开IPv6连接协议。 options FFS # Berkeley Fast Filesystem 这是最基本的硬盘文件系统,如果打算从本地硬盘启动,请保留它。 options SOFTUPDATES # Enable FFS Soft Updates support 这个选项会启用内核中的 Soft Updates 支持, 它会显著地提高磁盘的写入速度。 尽管这项功能是由内核直接提供的, 但仍然需要在每个磁盘上启用它。 请检查 &man.mount.8; 的输出, 以了解您系统中的磁盘上是否已经启用了 Soft Updates。 如果没有看到 soft-updates 选项, 则需要使用 &man.tunefs.8; (对于暨存系统) 或 &man.newfs.8; (对于新系统) 命令来激活它。 options UFS_ACL # Support for access control lists 这个选项将启用内核中的访问控制表的支持。 这依赖于扩展属性以及 UFS2, 以及在 中所介绍的那些特性。 ACL 默认是启用的, 并且如果已经在文件系统上使用了这一特性, 就不应再关掉它, 因为这会去掉文件的访问控制表, 并以不可预期的方式改变受保护的文件的访问方式。 options UFS_DIRHASH # Improve performance on big directories 通过使用额外的内存,这个选项可以加速在大目录上的磁盘操作。 您应该在大型服务器和频繁使用的工作站上打开这个选项,而在磁盘操作不是很重要的 小型系统上关闭它,比如防火墙。 options MD_ROOT # MD is a potential root device 这个选项将打开以基于内存的虚拟磁盘作为根设备的支持。 内核选项 NFS 内核选项 NFS_ROOT options NFSCLIENT # Network Filesystem Client options NFSSERVER # Network Filesystem Server options NFS_ROOT # NFS usable as /, requires NFSCLIENT 网络文件系统。 如果您不打算通过 TCP/IP 挂接 &unix; 文件服务器的分区, 就可以注释掉它。 内核选项 MSDOSFS options MSDOSFS # MSDOS Filesystem &ms-dos; 文件系统。 只要您不打算在启动时挂接由 DOS 格式化的硬盘分区, 就可以把它注释掉。 如前面所介绍的那样, 在您第一次挂接 DOS 分区时, 内核会自动加载需要的模块。 此外, emulators/mtools 软件提供了一个很方便的功能, 通过它您可以直接访问 DOS 软盘而无需挂接或卸下它们 (而且也完全不需要 MSDOSFS)。 options CD9660 # ISO 9660 Filesystem 用于 CDROM 的 ISO 9660 文件系统。 如果没有 CDROM 驱动器或很少挂接光盘数据 (因为在首次使用数据 CD 时会自动加载), 就可以把它注释掉。 音乐 CD 并不需要这个选项。 options PROCFS # Process filesystem (requires PSEUDOFS) 进程文件系统。 这是一个挂接在 /proc 的一个 假扮的 文件系统, 其作用是允许类似 &man.ps.1; 这样的程序给出正在运行的进程的进一步信息。 多数情况下, 并不需要使用 PROCFS, 因为绝大多数调试和监控工具, 已经进行了一系列修改, 使之不再依赖 PROCFS: 默认安装的系统中并不会挂接这一文件系统。 options PSEUDOFS # Pseudo-filesystem framework 在 6.X 内核中, 如果希望使用 PROCFS, 就必须加入 PSEUDOFS 的支持。 options GEOM_GPT # GUID Partition Tables. 这个选项提供了在磁盘上使用大量的分区的能力。 options COMPAT_43 # Compatible with BSD 4.3 [KEEP THIS!] 使系统兼容4.3BSD。不要去掉这一行,不然有些程序将无法正常运行。 options COMPAT_FREEBSD4 # Compatible with &os;4 为了支持在旧版本的&os;下编译的程序,该选项在&os; 5.X &i386;和Alpha systems下需要打开。 最好在所有的&i386;和Alpha systems下打开这个选项,因为可能要运行老应用程序。 在5.X才开始支持的平台,比如ia64和&sparc64;,就不需要这个选项。 options COMPAT_FREEBSD5 # Compatible with &os;5 对于 &os; 6.X 和更高版本而言, 如果希望在其上运行为 &os; 5.X 版本联编的、 用到 &os; 5.X 系统调用接口的程序, 则需要使用这个选项。 options SCSI_DELAY=5000 # Delay (in ms) before probing SCSI 这将让内核在探测每个 SCSI 设备之前等待 5 秒。 如果您只有 IDE 硬盘驱动器, 就可以不管它, 反之您可能会希望尝试降低这个数值以加速启动过程。 当然, 如果您这么做之后 &os; 在识别您的 SCSI 设备时遇到问题, 则您还需要再把它改回去。 options KTRACE # ktrace(1) support 这个选项打开内核进程跟踪,在调试时很有用。 options SYSVSHM # SYSV-style shared memory 提供System V共享内存(SHM)的支持,最常用到SHM的应该是X Window的XSHM延伸, 不少绘图相关程序会自动使用SHM来提供额外的速度。如果您要使用X Window,您最好加入这个选项。 options SYSVMSG # SYSV-style message queues 支持 System V 消息。 这只会在内核中增加数百字节的空间占用。 options SYSVSEM # SYSV-style semaphores 支持System V 信号量, 不常用到, 但只在kernel中占用几百个字节的空间。 &man.ipcs.1; 命令的 选项可以显示出任何用到这些 System V 机制的进程。 options _KPOSIX_PRIORITY_SCHEDULING # POSIX P1003_1B real-time extensions 在 1993 年 &posix; 添加的实时扩展。 在 Ports Collection 中某些应用程序会用到这些 (比如&staroffice;)。 options KBD_INSTALL_CDEV # install a CDEV entry in /dev 这个选项是在 /dev下建立键盘设备节点必需的。 options ADAPTIVE_GIANT # Giant mutex is adaptive. 内核全局锁 (Giant) 是一种互斥机制 (休眠互斥体) 的名字, 它用于保护许多内核资源。 现在, 这已经成为了一种无法接受的性能瓶颈, 它已经被越来越多地使用保护单个资源的锁代替。 ADAPTIVE_GIANT 选项将使得内核全局锁作为一种自适应自旋锁。 这意味着, 当有线程希望锁住内核全局锁互斥体, 但互斥体已经被另一个 CPU 上的线程锁住的时候, 它将继续运行, 直到那个线程释放锁为止。 一般情况下, 另一个线程将进入休眠状态并等待下一次调度。 如果您不确定是否应该这样做的话, 一般应该打开它。 请注意在 &os; 8.0-CURRENT 及以后的版本,所有的互斥体默认都是自适应的, 除非在编译时使用 NO_ADAPTIVE_MUTEXES 选项, 明确的指定为非自适应。因此,内核全局锁(Giant)目前默认也是自适应的, 而且 ADAPTIVE_GIANT 选项已经从内核配置文件中移出。 内核选项 SMP device apic # I/O APIC apic 设备将启用使用 I/O APIC 作为中断发送设备的能力。 apic 设备可以被 UP 和 SMP 内核使用, 但 SMP 内核必须使用它。 要支持多处理器, 还需要加上 options SMP The apic device exists only on the i386 architecture, this configuration line should not be used on other architectures. device eisa 如果您的主机板上有EISA总线,加入这个设置。使用这个选项可以自动扫描并设置所有连接在EISA总线上的设备。 device pci 如果您的主板有PCI总线,就加入这个选项。使用这个选项可以自动扫描PCI卡,并在PCI到ISA之间建立通路。 # Floppy drives device fdc 这是软驱控制器。 # ATA and ATAPI devices device ata 这个驱动器支持所有ATA和ATAPI设备。您只要在内核中加入device ata选项, 就可以让内核支持现代计算机上的所有PCI ATA/ATAPI设备。 device atadisk # ATA disk drives 这个是使用 ATAPI 硬盘驱动器时必须加入的选项。 device ataraid # ATA RAID drives 这个选项需要 device ata, 它用于 ATA RAID 驱动。 device atapicd # ATAPI CDROM drives 这个是ATAPI CDROM驱动器所必须的。 device atapifd # ATAPI floppy drives 这个是ATAPI 软盘驱动器所必须的。 device atapist # ATAPI tape drives 这个是ATAPI 磁带机驱动器所必须的. options ATA_STATIC_ID # Static device numbering 这指定对控制器使用其静态的编号; 如果没有这个选项, 则会动态地分配设备的编号。 # SCSI Controllers device ahb # EISA AHA1742 family device ahc # AHA2940 and onboard AIC7xxx devices options AHC_REG_PRETTY_PRINT # Print register bitfields in debug # output. Adds ~128k to driver. device ahd # AHA39320/29320 and onboard AIC79xx devices options AHD_REG_PRETTY_PRINT # Print register bitfields in debug # output. Adds ~215k to driver. device amd # AMD 53C974 (Teckram DC-390(T)) device isp # Qlogic family #device ispfw # Firmware for QLogic HBAs- normally a module device mpt # LSI-Logic MPT-Fusion #device ncr # NCR/Symbios Logic device sym # NCR/Symbios Logic (newer chipsets + those of `ncr') device trm # Tekram DC395U/UW/F DC315U adapters device adv # Advansys SCSI adapters device adw # Advansys wide SCSI adapters device aha # Adaptec 154x SCSI adapters device aic # Adaptec 15[012]x SCSI adapters, AIC-6[23]60. device bt # Buslogic/Mylex MultiMaster SCSI adapters device ncv # NCR 53C500 device nsp # Workbit Ninja SCSI-3 device stg # TMC 18C30/18C50 SCSI控制器。可以注释掉您系统中没有的设备。 如果您只有IDE设备,您可以把这些一起删掉。 *_REG_PRETTY_PRINT 这样的配置, 则是对应驱动程序的调试选项。 # SCSI peripherals device scbus # SCSI bus (required for SCSI) device ch # SCSI media changers device da # Direct Access (disks) device sa # Sequential Access (tape etc) device cd # CD device pass # Passthrough device (direct SCSI access) device ses # SCSI Environmental Services (and SAF-TE) SSCSI外围设备。也可以像上面一样操作。 目前系统提供的 USB &man.umass.4; 以及少量其它驱动使用了 SCSI 子系统, 尽管它们并不是真的 SCSI 设备。 因此, 如果在内核配置使用了这类驱动程序, 请务必不要删除 SCSI 支持。 # RAID controllers interfaced to the SCSI subsystem device amr # AMI MegaRAID device arcmsr # Areca SATA II RAID device asr # DPT SmartRAID V, VI and Adaptec SCSI RAID device ciss # Compaq Smart RAID 5* device dpt # DPT Smartcache III, IV - See NOTES for options device hptmv # Highpoint RocketRAID 182x device rr232x # Highpoint RocketRAID 232x device iir # Intel Integrated RAID device ips # IBM (Adaptec) ServeRAID device mly # Mylex AcceleRAID/eXtremeRAID device twa # 3ware 9000 series PATA/SATA RAID # RAID controllers device aac # Adaptec FSA RAID device aacp # SCSI passthrough for aac (requires CAM) device ida # Compaq Smart RAID device mfi # LSI MegaRAID SAS device mlx # Mylex DAC960 family device pst # Promise Supertrak SX6000 device twe # 3ware ATA RAID 支持RAID控制器。如果您没有这些,可以把它们注释掉或是删掉。 # atkbdc0 controls both the keyboard and the PS/2 mouse device atkbdc # AT keyboard controller 键盘控制器(atkbdc)提供AT键盘输入以及PS/2指针设备的I/O服务。 键盘驱动程序(atkbd)与PS/2鼠标驱动程序(psm)需要这个控制器,所以不要删除它。 device atkbd # AT keyboard atkbd驱动程序,与atkbdc控制器一起使用, 提供连接到AT键盘控制器的AT 84键盘与AT加强型键盘的访问服务。 device psm # PS/2 mouse 如果您的鼠标连接到PS/2鼠标端口,就使用这个设备驱动程序。 device kbdmux # keyboard multiplexer 针对键盘多路选择器的基本支持。 如果您不打算使用多个键盘, 则可以放心地删除这一行。 device vga # VGA video card driver 显卡驱动。 device splash # Splash screen and screen saver support 启动时的 splash 画面! 屏幕保护程序也需要这一选项。 # syscons is the default console driver, resembling an SCO console device sc sc 是默认的控制台驱动程序, 类似 SCO 控制台。 由于绝大部分全屏幕程序都通过类似 termcap 这样的终端数据库函数库赖访问控制台, 因此无论您使用这个或与 VT220 兼容的 vt 都没有什么关系。 如果您在运行这种控制台时使用全屏幕程序时发生问题, 请在登录之后将 TERM 变量设置为 scoansi # Enable this for the pcvt (VT220 compatible) console driver #device vt #options XSERVER # support for X server on a vt console #options FAT_CURSOR # start with block cursor 这是一个兼容 VT220 的控制台驱动, 它同时能够向下兼容 VT100/102。 在同 sc 硬件不兼容的一些笔记本上它能够运行的很好。 当然, 登录系统时请把 TERM 变量设置为 vt100vt220。 此驱动在连接网络上大量不同的机器时也被证明非常有用, 因为此时 termcapterminfo 通常没有可用的 sc 设备 — 而 vt100 则几乎每种平台都支持。 device agp 如果您的机器使用 AGP 卡, 请把上面一行加入配置。 这将启用 AGP, 以及某些卡上的 AGP GART 支持。 APM # 电源管理支持 (参见 NOTES 了解更多选项) #device apm 高级电源管理支持。对笔记本有用,不过在 GENERIC 里默认禁用。 # 增加 i8254 的 挂起/恢复 支持。 device pmtimer 用于电源管理事件, 例如 APM 和 ACPI 的时钟设备驱动。 # PCCARD (PCMCIA) support # PCMCIA and cardbus bridge support device cbb # cardbus (yenta) bridge device pccard # PC Card (16-bit) bus device cardbus # CardBus (32-bit) bus PCMCIA支持。如果您使用膝上型计算机,您需要这个。 # Serial (COM) ports device sio # 8250, 16[45]50 based serial ports 这些串口在 &ms-dos;/&windows; 的世界中称为 COM 口。 如果使用内置式的调制解调器, 并占用 COM4 而您另有一个串口在 COM2, 则必须把调制解调器的 IRQ 改为 2 (由于晦涩的技术原因, IRQ2 = IRQ 9) 才能够在 &os; 中访问它。 如果有多口的串口卡, 请参考 &man.sio.4; 以了解需要在 /boot/device.hints 中进行的设置。 某些显卡 (特别是基于 S3 芯片的卡) 使用形如 0x*2e8 的 IO 地址, 而许多廉价的串口卡不能够正确地对 16-位 IO 地址空间进行解码, 因此它们会产生冲突, 并造成 COM4 实际上无法使用。 每一个串口都需要有一个唯一的 IRQ (除非您使用支持中断分享的串口卡), 因此默认的 COM3COM4 IRQ 是不能使用的。 # Parallel port device ppc ISA-bus并行接口。 device ppbus # Parallel port bus (required) 提供并行总线的支持。 device lpt # Printer 提供并口打印机的支持。 要使用并口打印机,就必须同时加入上面三行设置。 device plip # TCP/IP over parallel 这是针对并行网络接口的驱动器。 device ppi # Parallel port interface device 普通用途的I/O (geek port) + IEEE1284 I/O. #device vpo # Requires scbus and da zip drive 这是针对Iomega Zip驱动器的。它要求scbusda的支持。 最好的执行效果是工作在EPP 1.9模式。 #device puc 如果您有由 &man.puc.4; 支持的 串行或并行 PCI 卡, 则应去掉这一行的注释。 # PCI Ethernet NICs. device de # DEC/Intel DC21x4x (Tulip) device em # Intel PRO/1000 adapter Gigabit Ethernet Card device ixgb # Intel PRO/10GbE Ethernet Card device txp # 3Com 3cR990 (Typhoon) device vx # 3Com 3c590, 3c595 (Vortex) 多种PCI网卡驱动器。注释或删除您系统中没有的设备. # PCI Ethernet NICs that use the common MII bus controller code. # NOTE: Be sure to keep the 'device miibus' line in order to use these NICs! device miibus # MII bus support MII总线支持对于一些PCI 10/100 Ethernet NIC来说是必需的。 device bce # Broadcom BCM5706/BCM5708 Gigabit Ethernet device bfe # Broadcom BCM440x 10/100 Ethernet device bge # Broadcom BCM570xx Gigabit Ethernet device dc # DEC/Intel 21143 and various workalikes device fxp # Intel EtherExpress PRO/100B (82557, 82558) device lge # Level 1 LXT1001 gigabit ethernet device msk # Marvell/SysKonnect Yukon II Gigabit Ethernet device nge # NatSemi DP83820 gigabit ethernet device nve # nVidia nForce MCP on-board Ethernet Networking device pcn # AMD Am79C97x PCI 10/100 (precedence over 'lnc') device re # RealTek 8139C+/8169/8169S/8110S device rl # RealTek 8129/8139 device sf # Adaptec AIC-6915 (Starfire) device sis # Silicon Integrated Systems SiS 900/SiS 7016 device sk # SysKonnect SK-984x & SK-982x gigabit Ethernet device ste # Sundance ST201 (D-Link DFE-550TX) device stge # Sundance/Tamarack TC9021 gigabit Ethernet device ti # Alteon Networks Tigon I/II gigabit Ethernet device tl # Texas Instruments ThunderLAN device tx # SMC EtherPower II (83c170 EPIC) device vge # VIA VT612x gigabit ethernet device vr # VIA Rhine, Rhine II device wb # Winbond W89C840F device xl # 3Com 3c90x (Boomerang, Cyclone) 使用MII总线控制器代码的驱动器。 # ISA Ethernet NICs. pccard NICs included. device cs # Crystal Semiconductor CS89x0 NIC # 'device ed' requires 'device miibus' device ed # NE[12]000, SMC Ultra, 3c503, DS8390 cards device ex # Intel EtherExpress Pro/10 and Pro/10+ device ep # Etherlink III based cards device fe # Fujitsu MB8696x based cards device ie # EtherExpress 8/16, 3C507, StarLAN 10 etc. device lnc # NE2100, NE32-VL Lance Ethernet cards device sn # SMC's 9000 series of Ethernet chips device xe # Xircom pccard Ethernet # ISA devices that use the old ISA shims #device le ISA 以太网卡驱动。 参见 /usr/src/sys/i386/conf/NOTES 以了解关于哪个驱动程序能够驱动您的网卡的细节。 # Wireless NIC cards device wlan # 802.11 support 通用 802.11 支持。 这行配置是无线网络所必需的。 device wlan_wep # 802.11 WEP support device wlan_ccmp # 802.11 CCMP support device wlan_tkip # 802.11 TKIP support 针对 802.11 设备的加密支持。 如果希望使用加密和 802.11i 安全协议, 就需要这些配置行。 device an # Aironet 4500/4800 802.11 wireless NICs. device ath # Atheros pci/cardbus NIC's device ath_hal # Atheros HAL (Hardware Access Layer) device ath_rate_sample # SampleRate tx rate control for ath device awi # BayStack 660 and others device ral # Ralink Technology RT2500 wireless NICs. device wi # WaveLAN/Intersil/Symbol 802.11 wireless NICs. #device wl # Older non 802.11 Wavelan wireless NIC. 用以支持多种无线网卡。 # Pseudo devices device loop # Network loopback 这是 TCP/IP 的通用回环设备。 如果您 telnet 或 FTP 到 localhost (也就是 127.0.0.1) 则将通过这个设备回到本机。 这个设备是 必需的 device random # Entropy device Cryptographically secure random number generator. device ether # Ethernet support ether 只有在使用以太网卡时才需要。 它包含了通用的以太网协议代码。 device sl # Kernel SLIP sl 用以提供 SLIP 支持。 目前它几乎已经完全被 PPP 取代了, 因为后者更容易配置, 而且更适合调制解调器之间的连接, 并提供了更强大的功能。 device ppp # Kernel PPP 这一选项用以提供内核级的 PPP 支持, 用于拨号连接。 也有以用户模式运行的 PPP 实现, 使用 tun 并提供包括按需拨号在内的更为灵活的功能。 device tun # Packet tunnel. 它会被用户模式的 PPP 软件用到。 参考本书的 PPP 以了解更多的细节。 device pty # Pseudo-ttys (telnet etc) 这是一个 pseudo-terminal 或模拟登入端口。 它用来接收连入的 telnet 以及 rlogin 会话、 xterm, 以及一些其它程序如 Emacs 等。 device md # Memory disks 内存盘伪设备。 device gif # IPv6 and IPv4 tunneling 它实现了在 IPv4 上的 IPv6 隧道、 IPv6 上的 IPv4 隧道、 IPv4 上的 IPv4 隧道、 以及IPv6 上的 IPv6隧道。 gif 设备是 自动克隆 的, 它会根据需要自动创建设备节点。 device faith # IPv6-to-IPv4 relaying (translation) 这个伪设备能捕捉发给它的数据包,并把它们转发给 IPv4/IPv6 翻译服务程序。 # The `bpf' device enables the Berkeley Packet Filter. # Be aware of the administrative consequences of enabling this! # Note that 'bpf' is required for DHCP. device bpf # Berkeley packet filter 这是 Berkeley 包过滤器。这个伪设备允许网络接口被置于混杂模式, 从而,截获广播网 (例如,以太网) 上的每一个数据包。 截获的数据报可以保存到磁盘上,也可以使用 &man.tcpdump.1; 程序来分析。 &man.bpf.4; 设备也被用于 &man.dhclient.8; 来获取默认路由器(网关)的 IP 地址。如果使用DHCP,就不要注释掉这行。 # USB support device uhci # UHCI PCI->USB interface device ohci # OHCI PCI->USB interface device ehci # EHCI PCI->USB interface (USB 2.0) device usb # USB Bus (required) #device udbp # USB Double Bulk Pipe devices device ugen # Generic device uhid # Human Interface Devices device ukbd # Keyboard device ulpt # Printer device umass # Disks/Mass storage - Requires scbus and da device ums # Mouse device ural # Ralink Technology RT2500USB wireless NICs device urio # Diamond Rio 500 MP3 player device uscanner # Scanners # USB Ethernet, requires mii device aue # ADMtek USB Ethernet device axe # ASIX Electronics USB Ethernet device cdce # Generic USB over Ethernet device cue # CATC USB Ethernet device kue # Kawasaki LSI USB Ethernet device rue # RealTek RTL8150 USB Ethernet 支持各类 USB 设备。 # FireWire support device firewire # FireWire bus code device sbp # SCSI over FireWire (Requires scbus and da) device fwe # Ethernet over FireWire (non-standard!) 支持各类火线设备。 要了解 &os; 所支持的设备的其他情况, 请参考 /usr/src/sys/i386/conf/NOTES 大内存支持(<acronym>PAE</acronym>) 物理地址扩展 (PAE) 大内存 大内存配置的机器需要超过4GB的虚拟地址。 因为4GB的限制,Intel在&pentium;及后续的CPUs上增加了36位物理地址的支持。 物理地址扩展 (PAE) 是 &intel; &pentium; Pro和后续的 CPU 提供的一种允许将内存地址扩展到 64GB 的功能, &os; 的所有最新版本均支持此功能, 并通过 选项来启用这个能力。 因为Intel架构的限制, 高于或低于 4GB 都没有什么区别, 超过 4GB 的内存分配只是简单地添加到可用内存池中。 为了让内核支持PAE,只要增加下面这一行到配置文件: options PAE PAE在&os;里面现在只能支持 &intel; IA-32处理器。 同时,还应该注意,&os;的PAE支持没有经过广泛的测试, 和其他稳定的特性相比只能当作是beta版。 PAE在&os;下有如下的一些限制: 进程不能接触大于4GB的VM空间。 - - KLD 模块不能加载到一个打开了PAE支持的内核里面, - 这是因为内核模块和内核的建立框架不一样。 - - 没有使用 &man.bus.dma.9; 接口的设备驱动程序在打开了 PAE 支持的内核中会导致数据损坏。 因为这个原因, PAE 内核配置文件 会把所有在打开了 PAE 的内核上不能工作的驱动程序排除在外。 一些系统打开了探测系统内存资源使用能力的功能,因为打开了 PAE支持,这些功能可能会被覆盖掉。 其中一个例子就是内核参数,它是控制 内核能使用的最大vnodes数目的,建议重新调整它及其他类似参数到合适的值。 为了避免KVA的消耗,很有必要增加系统的内核虚拟地址, 或者减少很耗系统资源的内核选项的总量(看上面)。选项 可以用来增加KVA空间。 为了稳定和高性能,建议查看&man.tuning.7;手册页。&man.pae.4;手册页包含 &os;'sPAE支持的最新信息。 如果出现问题怎么办 在定制一个内核时,可能会出现四种问题。它们是: config失败: 如果 &man.config.8; 在给出您的内核描述时失败, 则可能在某些地方引入了一处小的错误。 幸运的是, &man.config.8; 会显示出它遇到问题的行号, 这样您就能够迅速地定位错误。 例如, 如果您看到: config: line 17: syntax error 可以通过与 GENERIC 或其他参考资料对比, 来确定这里的关键词是否拼写正确。 make失败: 如果 make 命令失败, 它通常表示内核描述中发生了 &man.config.8; 无法找出的的错误。 同样地, 仔细检查您的配置, 如果仍然不能解决问题, 发一封邮件到 &a.questions; 并附上您的内核配置, 则问题应该很快就能解决。 内核无法启动: 如果您的内核无法启动, 或不识别您的设备, 千万别慌! 非常幸运的是, &os; 有一个很好的机制帮助您从不兼容的内核恢复。 在 &os; 启动加载器那里简单地选择一下要启动的内核就可以了。 当系统在引导菜单的 10 秒倒计时时进入它, 方法是选择 Escape to a loader prompt 选项, 其编号为 6。 输入 unload kernel, 然后输入 boot /boot/kernel.old/kernel, 或者其他任何一个可以正确引导的内核即可。 当重新配置内核时, 保持一个已经证明能够正常启动的内核永远是一个好习惯。 当使用好的内核启动之后您可以检查配置文件并重新尝试编译它。 比较有用的资源是 /var/log/messages 文件, 它会记录每次成功启动所产生的所有内核消息。 此外, &man.dmesg.8; 命令也会显示这次启动时产生的内核消息。 如果在编译内核时遇到麻烦, 请务必保留一个 GENERIC 或已知可用的其他内核, 并命名为别的名字以免在下次启动时被覆盖。 不要依赖 kernel.old 因为在安装新内核时, kernel.old 会被上次安装的那个可能不正常的内核覆盖掉。 另外, 尽快把可用的内核挪到 /boot/kernel 否则类似 &man.ps.1; 这样的命令可能无法正常工作。 为了完成这一点, 需要修改目录的名字: &prompt.root; mv /boot/kernel /boot/kernel.bad &prompt.root; mv /boot/kernel.good /boot/kernel 内核工作,但是&man.ps.1;根本不工作: 如果您安装了一个与系统中内建工具版本不同的内核, 例如在 -STABLE 系统上安装了 -CURRENT 的内核, 许多用于检查系统状态的工具如 &man.ps.1; 和 &man.vmstat.8; 都将无法正常使用。 您应该 重新编译一个和内核版本一致的系统。 这也是为什么一般不鼓励使用与系统其他部分版本不同的内核的一个主要原因。 diff --git a/zh_CN.GB2312/books/handbook/l10n/chapter.sgml b/zh_CN.GB2312/books/handbook/l10n/chapter.sgml index fcd7ea74ba..2526d4d70f 100644 --- a/zh_CN.GB2312/books/handbook/l10n/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/l10n/chapter.sgml @@ -1,849 +1,849 @@ Andrey Chernov Contributed by Michael C. Wu Rewritten by 本地化-I18N/L10N使用和设置 概述 FreeBSD是一个由分布于全世界的用户和贡献者支持的项目。 这章将讨论FreeBSD的国际化和本地化的问题,允许非英语用户也能使用FreeBSD很好地工作。 在系统和应用水平上,主要是通过执行i18N标准来实现的,所以这里我们将为读者提供详细的介绍。 读完这一章,您将了解到: 不同的语言和地域是如何在现代操作系统上进行编码的。 如何为您的登入shell设置本地化。 如何配置您的控制台为非英语语言。 languages. 如何使用不同的语言来有效地使用X Windows。 在哪里可以找到更多有关开发符合i18N标准的应用程序的信息。 阅读这章之前,您应当了解: 怎样安装额外的第三方程序()。 基础知识 I18N/L10N 是什么? 国际化 本地化 本地化 开发人员把internationalization简写成I18N,中间的数字是前后两个字母间的字母个数。 L10N依据localization 使用同样的命名规则。 I18N/L10N方法、协议和应用结合在一起,允许用户使用他们自己所选择的语言。 I18N应用程序使用I18N工具来编程。它允许开发人员写一个简单的文件, 就可以将显示的菜单和文本翻译成本地语言。我们非常鼓励程序员遵循这种规则。 为什么要使用I18N/L10N? I18N/L10N标准能够很好地支持您查看、输入或处理非英语语言。 I18N支持哪些语言? I18N和L10N不是FreeBSD特有的。当前,它能支持世界上绝大部分主力语言, 包括但不限于:中文,德文,日文,朝鲜文,法文,俄文,越南文等等。 使用本地化语言 I18N不是FreeBSD特有的,它是一个规则。我们鼓励您帮助FreeBSD完善这一规则。 locale 本地化设置需要具备三个条件:语言代码 (Language Code)、 国家代码 (Country Code) 和编码(Encoding)。 本地名字可以用下面这些部分来构造: 语言代码_国家代码.编码 语言和国家代码 语言代码 国家代码 为了用特殊的语言来对FreeBSD系统进行本地化(或其他类&unix;系统), 用户必须要知道相应的国家和语言代码(国家代码告诉应用程序使用哪一种语言规范)。 此外,WEB浏览器,SMTP/POP服务器,web服务器等都是以这个为基础的。下面就是一个国家和语言代码的例子: 语言/国家代码 描述 en_US 美国英语 ru_RU 俄语 zh_CN 简体中文 编码 编码 ASCII 一些语言不使用 ASCII 编码,它们使用8-位, 宽或多字节的字符, 更多的信息请参考 &man.multibyte.3;。 比较老的应用程序可能会无法识别它们, 并误认为是控制字符。 比较新的应用程序通常会认出 8-位字符。 随实现的不同, 用户可能不得不将宽或多字节字符支持编入应用程序, 或进行一些额外的配置, 才能够正常使用它们。 要输入和处理宽或多字节字符, FreeBSD Ports Collection 已经为每种语言提供了不同的程序。 请参考各个 FreeBSD Port 中的 I18N 文档。 特别需要指出的是, 用户可能需要查看应用程序的文档, 以确定如何正确地配置它, 或需要为 configure/Makefile/编译器 指定什么样的参数。 记住下面这些: 特定语言的简单C字符集 (参见 &man.multibyte.3;),例如 ISO8859-1, ISO8859-15, KOI8-R, CP437。 宽字节或多字节编码,如EUC, Big5。 您可以在IANA Registry检查一下现行的字符集列表。 与此不同的是, &os; 使用与 X11-兼容的本地编码模式。 I18N应用程序 在FreeBSD Ports和Package系统里面,I18N应用程序已经使用I18N 来命名。然而它们不是总支持需要的语言。 本地化设置 通常只要在登入shell里面设置LANG为本地化, 一般通过设置用户的 ~/.login_conf 或用户shell的启动文件(~/.profile~/.bashrc, ~/.cshrc)。没有必要设置 LC_CTYPELC_CTIME。 更多的信息请参考特定语言的FreeBSD文档。 您应当在您的配置文件中设置下面两个变量: POSIX LANG 为&posix;设置本地化语言功能。 MIME MM_CHARSET应用程序的MIME字符集。 这包括用户的shell配置,特定的应用配置和X11配置。 设置本地化的方法 本地化 登入分类 有两种方法来设置本地化,接下来都会描述。 第一种 (推荐) 就是在 登入分类里面指定环境变量。 第二种方法是把环境变量加到shell的启动文件里面。 登入分类方法 这种方法允许把本地化名称和MIME字符集的环境变量赋给可能的shell, 而不是加到每个特定shell的启动文件里面。 用户级设置 Level Setup 允许普通用户自己完成这个设置,而管理员级设置需要超级用户权限。 用户级设置 这有一个设置用户根目录文件.login_conf的小例子, 它为上述两个变量设置了Latin-1编码。 me:\ :charset=ISO-8859-1:\ :lang=de_DE.ISO8859-1: 繁体中文BIG-5编码 这是一个为.login_conf设置繁体中文的BIG-5编码的例子。应该设置下面的大部分变量, 因为很多软件都没有为中文,日文和韩文设置正确的本地化变量。 #Users who do not wish to use monetary units or time formats #of Taiwan can manually change each variable me:\ :lang=zh_TW.Big5:\ :setenv=LC_ALL=zh_TW.Big:\ :setenv=LC_COLLATE=zh_TW.Big5:\ :setenv=LC_CTYPE=zh_TW.Big5:\ :setenv=LC_MESSAGES=zh_TW.Big5:\ :setenv=LC_MONETARY=zh_TW.Big5:\ :setenv=LC_NUMERIC=zh_TW.Big5:\ :setenv=LC_TIME=zh_TW.Big5:\ :charset=big5:\ :xmodifiers="@im=gcin": #Set gcin as the XIM Input Server 更多的信息参考管理员级设置和&man.login.conf.5; 管理员级设置 检查用户的登入分类在 /etc/login.conf里面是否设置了正确的语言。主要确定下面的几个设置: language_name:accounts_title:\ :charset=MIME_charset:\ :lang=locale_name:\ :tc=default: 再次使用前面的Latin-1编码的例子: german:German Users Accounts:\ :charset=ISO-8859-1:\ :lang=de_DE.ISO8859-1:\ :tc=default: 在修改用户的登入类型之前, 应首先执行下面的命令: &prompt.root; cap_mkdb /etc/login.conf 以便使在 /etc/login.conf 中新增的配置生效。 使用 &man.vipw.8; 改变登入类型。 vipw 使用vipw添加新用户,看起来像下面这样: user:password:1111:11:language:0:0:User Name:/home/user:/bin/sh 用&man.adduser.8;改变登入类型。 adduser 登入分类 adduser添加新用户看起来像下面这样: /etc/adduser.conf里面设置defaultclass = 语言。应该记住,您必须为使用其它语言的所有用户设置 缺省类别。 每一次使用&man.adduser.8;的时候,一个特定语言的可选择性回答会像下面这样给出: Enter login class: default []: 如果您打算给每一个用户使用另外一种语言,您应该这样: &prompt.root; adduser -class language 使用&man.pw.8;改变登入类型。 pw 如果您使用&man.pw.8;来添加新用户,应该这样使用: &prompt.root; pw useradd user_name -L language Shell启动文件方法 不推荐使用这种方法,因为它需要给每一个可能的shell程序一个不同的启动文件。 应该用登入分类方法来代替这种方法。 MIME locale 为了设置本地化名称和MIME字符集,只要在/etc/profile/etc/csh.login启动文件里面设置这两个变量。下面我们使用德语做例子: /etc/profile里面: LANG=de_DE.ISO8859-1; export LANG MM_CHARSET=ISO-8859-1; export MM_CHARSET 或在/etc/csh.login里面: setenv LANG de_DE.ISO8859-1 setenv MM_CHARSET ISO-8859-1 另外,您可以把上面的设置添加到/usr/share/skel/dot.profile (和前面的/etc/profile一样),或者/usr/share/skel/dot.login (和前面的/etc/csh.login一样)。 对于X11: $HOME/.xinitrc里面: LANG=de_DE.ISO8859-1; export LANG 或者: setenv LANG de_DE.ISO8859-1 依赖您的shell(看上面)。 控制台设置 对于所有的简单C字符集,在/etc/rc.conf中用正在讨论的语言设置正确的控制台字符: font8x16=font_name font8x14=font_name font8x8=font_name 这儿的font_name来自于/usr/share/syscons/fonts目录, 不带.fnt后缀。 sysinstall keymap screenmap 您还需要确定正确地为您的 C 字符集配置了 keymap 和 screenmap, 这一工作可以通过 sysinstall (在 &os; 5.2 之前的版本是 /stand/sysinstall) 来完成。。 进入 sysinstall 之后, 选择 ConfigureConsole。 此外, 您也可以将下面的设置加入 /etc/rc.conf scrnmap=screenmap_name keymap=keymap_name keychange="fkey_number sequence" 这儿的screenmap_name是来自/usr/share/syscons/scrnmaps目录, 不带.scm后缀。 一个带影射字体的屏幕布局通常被作为一个工作区, 用来在VGA适配器字体矩阵上扩展8位到9位。 如果屏幕字体是使用一个8位的排列,要移动这些字母离开这些区域。 如果您在/etc/rc.conf里面启用了moused daemon: moused_enable="YES" 那么需要在下一段检查鼠标指针信息。 moused 默认情况下, &man.syscons.4;驱动程序的鼠标指针在字符集中占用0xd0-0xd3的范围。 如果您的语言使用这个范围,您必须把指针范围移出这个范围。 要绕过这个问题, 需要在 /etc/rc.conf 中加入: mousechar_start=3 这里, keymap_name 来自于 /usr/share/syscons/keymaps 目录, 但去掉了 .kbd 后缀。 如果不确定应该使用哪一个键盘布局, 则可以使用 &man.kbdmap.1; 来测试, 而无需反复重启。 通常, keychange 是设定功能键时, 匹配选定的终端类型来说是必需的, 因为功能键序列无法在键盘布局中定义。 此外您还应该检查并确认在 /etc/ttys 中已经为所有的 ttyv* 项配置了正确的终端类型。 目前, 相关的默认定义是: 字符集设置 终端类型 ISO8859-1 or ISO8859-15 cons25l1 ISO8859-2 cons25l2 ISO8859-7 cons25l7 KOI8-R cons25r KOI8-U cons25u CP437 (VGA default) cons25 US-ASCII cons25w 对于多字节字符语言,可以您的在 /usr/ports/language 目录中使用正确的FreeBSD port。一些port以控制台出现, 而系统把它作为串行vtty终端,因此, 必须为 X11 和伪串行控制台准备足够的vtty终端。 下面是在控制台中使用其他语言的应用程序的部分列表: 语言 特定区域 Traditional Chinese (BIG-5) chinese/big5con Japanese japanese/kon2-16dot or japanese/mule-freewnn Korean korean/han X11设置 虽然X11不是FreeBSD计划的一部分, 但我们已经为FreeBSD用户包含了一些信息。 具体细节可以参考&xorg; Web 站点 或是您使用的 X11 Server 的网站。 ~/.Xresources里面,您可以适当调整特定应用程序的I18N设置(如字体,菜单等)。 显示字体 X11 True Type 字体服务器 安装 &xorg; 服务器 (x11-servers/xorg-server) 或 &xfree86; 服务器 (x11-servers/XFree86-4-Server), 然后安装对应语言的 &truetype; 字体。 请设置正确的地区信息, 这将让您能够在菜单和其它地方看到所选择的语言。 输入非英语字符 X11输入方法(XIM) X11输入方法(XIM)协议是所有X11客户端的一个新标准。 所有将作为XIM客户端来写的X11应用程序从XIM输入服务器输入。 不同的语言有几种XIM服务器可用。 打印机设置 一些简单的C字符集通常是用硬编码来编码进打印机的。更宽或多位的字符集需要特定的设置, 我们推荐使用apsfilter。您也可以使用特定语言转换器把文档转换为 &postscript;或PDF格式。 内核和文件系统 FreeBSD 的快速文件系统 (FFS) 是完全支持 8-位 字符的, 因此它可以被用于任何简单的 C 字符集 (参见 &man.multibyte.3;), 但在文件系统中不会保存字符集的名字; 也就是说, 它不加修改地保存 8-位信息, 而并不知道如何编码。 正式说来, FFS 目前还不支持任何形式的宽或多字节字符集。 不过, 某些宽或多字符集提供了独立的针对 FFS 的补丁来帮助启用关于它们的支持。 目前这些要么是无法移植的, 要么过于粗糙, 因此我们不打算把它们加入到源代码中。 请参考相关语言的 Web 站点, 以了解关于这些补丁的进一步情况。 DOS Unicode FreeBSD &ms-dos;已经能够配置成用在&ms-dos;上,Unicode字符集和可选的FreeBSD文件系统字符集的更多信息, 请参考 &man.mount.msdosfs.8; 联机手册。 编译I18N程序 许多FreeBSD Ports已经支持I18N了。他们中的一些都用-I18N作标记。 这些和其他很多程序已经内建I18N的支持,不需要考虑其他的事项了。 MySQL 然而一些像MySQL这样的应用程序需要重新配置字符集,可在 Makefile里面设置,或者直接把参数传递给configure 本地化FreeBSD Andrey Chernov Originally contributed by 俄语(KOI8-R编码) 本地化 俄语 关于KOI8-R编码的更多信息请查阅KOI8-R参考(Russian Net Character Set) 本地设置 把下面的行加入到您的~/.login_conf文件: me:My Account:\ :charset=KOI8-R:\ :lang=ru_RU.KOI8-R: 参看前面的设置本地化的例子。 控制台设置 把下面一行加到 /etc/rc.conf mousechar_start=3 并在 /etc/rc.conf 里面增加如下设置: keymap="ru.koi8-r" scrnmap="koi8-r2cp866" font8x16="cp866b-8x16" font8x14="cp866-8x14" font8x8="cp866-8x8" 对于/etc/ttys里面的ttyv*记录,要使用 cons25r作为终端类型。 参看前面的设置控制台的例子。 打印机设置 打印机 既然绝大多数带俄语字符的打印机遵循CP866的标准, 那么需要一个针对KOI8-R到CP866转换的特定输出过滤器。这样的一个过滤器默认的安装在 /usr/libexec/lpr/ru/koi2alt。 一个支持俄语的打印机的/etc/printcap记录看起来是这样的: lp|Russian local line printer:\ :sh:of=/usr/libexec/lpr/ru/koi2alt:\ :lp=/dev/lpt0:sd=/var/spool/output/lpd:lf=/var/log/lpd-errs: 更多信息参考&man.printcap.5;手册页。 &ms-dos;文件系统和俄语文件名 下面的例子是在挂上&ms-dos; 文件系统后,启用对俄语文件名支持的&man.fstab.5;记录: /dev/ad0s2 /dos/c msdos rw,-Wkoi2dos,-Lru_RU.KOI8-R 0 0 选项 用于选择地区名称, 而 则用于设置字符转换表。 要使用 选项, 则一定要首先挂接 /usr, 然后再挂接 &ms-dos; 分区, 因为转换表是放在 /usr/libdata/msdosfs 的。 要了解进一步的细节, 请参考 &man.mount.msdosfs.8; 联机手册。 X11设置 首先请进行前面介绍的 非-X 的本地化设置。 如果您正使用 &xorg;, 请安装 x11-fonts/xorg-fonts-cyrillic package。 检查您 /etc/X11/xorg.conf 文件中的 "Files" 小节。 下面的行, 应加到任何其它 FontPath 项之前: FontPath "/usr/X11R6/lib/X11/fonts/cyrillic/misc" FontPath "/usr/X11R6/lib/X11/fonts/cyrillic/75dpi" FontPath "/usr/X11R6/lib/X11/fonts/cyrillic/100dpi" 如果希望使用高分辨率的现实模式, 则应把 100 dpi 的配置行放在 75 dpi 前面。 请查看 ports 中的其它西里尔字体。 要激活俄语键盘, 需要在 xorg.conf 文件的 "Keyboard" 小节中加入下列内容: Option "XkbLayout" "us,ru" Option "XkbOptions" "grp:toggle" 要确信XkbDisable 已经关闭 (注释掉) 了。 RUS/LAT的切换用CapsLock。老的CapsLock功能可以通过 ShiftCapsLock 来模拟(只有在LAT模式的时候)。 使用 grp:caps_toggle 时, RUS/LAT 切换键将是 右 Alt, 而使用 grp:ctrl_shift_toggle 则表示切换键是 CtrlShift。 旧的 CapsLock 功能仍可通过 ShiftCapsLock (只对 LAT 模式有效)。 对于 grp:toggle 而言 RUS/LAT 开关则是 Right Alt。 由于不明原因, grp:caps_toggle&xorg; 中无法使用。 如果您的键盘上有 &windows; 键, 但发现 RUS 模式下, 某些非字母键映射不正常, 则应在您的 xorg.conf 文件中加入下面这行: Option "XkbVariant" ",winkeys" 俄语的 XKB 键盘可能并不为某些不具备本地化功能的应用程序所支持。 本地化程序最低限度应在程序启动时调用 XtSetLanguageProc (NULL, NULL, NULL); 函数。 参见 KOI8-R for X Window 以获得关于对 X11 应用进行本地化的指导。 设置繁体中文 本地化 繁体中文 FreeBSD-Taiwan计划有一个使用很多中文ports的中文化指南在 。 目前, FreeBSD 中文化指南 的维护人员是 沈俊兴 statue@freebsd.sinica.edu.tw 沈俊兴 statue@freebsd.sinica.edu.tw 利用 FreeBSD-Taiwan 的 zh-L10N-tut建立了 Chinese FreeBSD Collection (CFC)。 相关的 packages 和脚本等可以在 找到。 德语本地化(适合所有的ISO 8859-1语言) 本地化 德语 Slaven Rezic eserte at cs.tu-berlin.de 写了一个在FreeBSD机器下如何使用日尔曼语言的德语指南。 这份德语教程可以在 找到。 日语和韩语本地化 本地化 日语 本地化 韩语 日语本地化请参考,韩语参考 非英语的FreeBSD文档 一些FreeBSD的贡献者已经将部分FreeBSD文档翻译成了其他语言。 可以通过主站 或者 /usr/share/doc 查到。 diff --git a/zh_CN.GB2312/books/handbook/mac/chapter.sgml b/zh_CN.GB2312/books/handbook/mac/chapter.sgml index b6e076cc9b..fde94d2be2 100644 --- a/zh_CN.GB2312/books/handbook/mac/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/mac/chapter.sgml @@ -1,1777 +1,1772 @@ Tom Rhodes 原作 强制访问控制 概要 MAC 强制访问控制 MAC &os; 5.X 在 &posix;.1e 草案的基础上引入了 TrustedBSD 项目提供的新的安全性扩展。 新安全机制中最重要的两个, 是文件系统访问控制列表 (ACL) 和强制访问控制 (MAC) 机制。 强制访问控制允许加载新的访问控制模块, 并借此实施新的安全策略, 其中一部分为一个很小的系统子集提供保护并加强特定的服务, 其他的则对所有的主体和客体提供全面的标签式安全保护。 定义中有关强制的部分源于如下事实, 控制的实现由管理员和系统作出, 而不像自主访问控制 (DAC, &os; 中的标准文件以及 System V IPC 权限) 那样是按照用户意愿进行的。 本章将集中讲述强制访问控制框架 (MAC 框架) 以及一套用以实施多种安全策略的插件式的安全策略模块。 阅读本章之后, 您将了解: 目前 &os; 中具有哪些 MAC 安全策略模块, 以及与之相关的机制。 MAC 安全策略模块将实施何种策略, 以及标签式与非标签式策略之间的差异。 如何高效地配置系统令使其使用 MAC 框架。 如何配置 MAC 框架所提供的不同的安全策略模块。 如何用 MAC 框架构建更为安全的环境, 并举例说明。 如何测试 MAC 配置以确保正确构建了框架。 阅读本章之前, 您应该: 了解 &unix; 和 &os; 的基础 ()。 熟悉内核配置/编译 () 的基础。 对安全及其如何与 &os; 相配合有些了解; ()。 对本章信息的不当使用可能导致丧失系统访问权, 激怒用户, 或者无法访问 X11 提供的特性。 更重要的是, MAC 不能用于彻底保护一个系统。 MAC 框架仅用于增强现有安全策略; 如果没有健全的安全条例以及定期的安全检查, 系统将永远不会绝对安全。 此外还需要注意的是, 本章中所包含的例子仅仅是例子。 我们并不建议在一个生产用系统上进行这些特别的设置。 实施各种安全策略模块需要谨慎的考虑与测试, 因为那些并不完全理解所有机制如何工作的人, 可能会发现需要对整个系统中很多的文件或目录进行重新配置。 未涉及的内容 本章涵盖了与 MAC 框架有关的诸多方面的安全问题; 而新的 MAC 安全策略模块的开发成果则不会涉及。 MAC 框架中所包含的一部分安全策略模块, 具有一些用于测试及新模块开发的特定属性, 其中包括 &man.mac.test.4;、 &man.mac.stub.4; 以及 &man.mac.none.4;。 关于这些安全策略模块及其提供的众多机制的详细信息,请参阅联机手册中的内容。 本章出现的重要术语 在阅读本章之前, 有些关键术语需要解释, 希望能藉此扫清可能出现的疑惑, 并避免在文中对新术语、 新信息进行生硬的介绍。 区间(compartment): (译注: 区间 这一术语, 在一些文献中也称做类别 (category)。 此外, 在其它一些翻译文献中, 该术语也翻译为 象限。) 指一组被划分或隔离的程序和数据, 其中, 用户被明确地赋予了访问特定系统组件的权限。 同时, 区间也能够表达分组, 例如工作组、 部门、 项目, 或话题。 可以通过使用区间来实施 need-to-know 安全策略。 高水位线(high water mark): 高水位线策略是一种允许提高安全级别, 以期访问更高级别的信息的安全策略。 在多数情况下, 当进程结束时, 又会回到原先的安全级别。 目前, &os; MAC 框架尚未提供这样的策略, 在这里介绍其定义主要是希望给您一个完整的概念。 完整性(integrity): 作为一个关键概念, 完整性是数据可信性的一种程度。 若数据的完整性提高, 则数据的可信性相应提高。 标签(label): 标签是一种可应用于文件、 目录或系统其他客体的安全属性, 它也可以被认为是一种机密性印鉴。 当一个文件被施以标签时, 其标签会描述这一文件的安全参数, 并只允许拥有相似安全性设置的文件、 用户、 资源等访问该文件。 标签值的涵义及解释取决于相应的策略配置: 某些策略会将标签当作对某一客体的完整性和保密性的表述, 而其它一些策略则会用标签保存访问规则。 程度(level): 对某种安全属性加强或削弱的设定。 若程度增加, 其安全性也相应增加。 低水位线(low water mark): 低水位线策略允许降低安全级别, 以访问安全性较差的信息。 多数情况下, 在进程结束时, 又会回到原先的安全级别。 目前在 &os; 中唯一实现这一安全策略的是 &man.mac.lomac.4;。 多重标签(multilabel): 属性是一个文件系统选项。 该选项可在单用户模式下通过 &man.tunefs.8; 程序进行设置。 可以在引导时使用的 &man.fstab.5; 文件中, 也可在创建新文件系统时进行配置。 该选项将允许管理员对不同客体施以不同的 MAC 标签。 该选项仅适用于支持标签的安全策略模块。 客体(object): 客体或系统客体是一种实体, 信息随 主体 的导向在客体内部流动。 客体包括目录、 文件、 区段、 显示器、 键盘、 存储器、 磁存储器、 打印机及其它数据存储/转移设备。 基本上, 客体就是指数据容器或系统资源。 对 客体 的访问实际上意味着对数据的访问。 策略(policy): 一套用以规定如何达成目标的规则。 策略 一般用以描述如何对特定客体进行操作。 本章将在安全策略的范畴内讨论策略, 一套用以控制数据和信息流并规定其访问者的规则,就是其中一例。 敏感性(sensitivity): 通常在讨论 MLS 时使用。 敏感性程度曾被用来描述数据应该有何等的重要或机密。 若敏感性程度增加, 则保密的重要性或数据的机密性相应增强。 单一标签(single label): 整个文件系统使用一个标签对数据流实施访问控制, 叫做单一标签。 当文件系统使用此设置时, 即无论何时当 选项未被设定时, 所有文件都将遵守相同标签设定。 主体(subject): 主体就是引起信息在两个 客体 间流动的任意活动实体, 比如用户, 用户进程(译注:原文为 processor), 系统进程等。 在 &os; 中, 主体几乎总是代表用户活跃在某一进程中的一个线程。 关于 MAC 的说明 在掌握了所有新术语之后, 我们从整体上来考虑 MAC 是如何加强系统安全性的。 MAC 框架提供的众多安全策略模块可以用来保护网络及文件系统, 也可以禁止用户访问某些特定的端口、 套接字及其它客体。 将策略模块组合在一起以构建一个拥有多层次安全性的环境, 也许是其最佳的使用方式, 这可以通过一次性加载多个安全策略模块来实现。 在多层次安全环境中, 多重策略模块可以有效地控制安全性, 这一点与强化型 (hardening) 策略, 即那种通常只强化系统中用于特定目的的元素的策略是不同的。 相比之下, 多重策略的唯一不足是需要系统管理员先期设置好参数, 如多重文件系统安全标志、 每一位用户的网络访问权限等等。 与采用框架方式实现的长期效果相比, 这些不足之处是微不足道的。 例如, 让系统具有为特定配置挑选必需的策略的能力, 有助于降低性能开销。 而减少对无用策略的支持, 不仅可以提高系统的整体性能, 而且提供了更灵活的选择空间。 好的实施方案中应该考虑到整体的安全性要求, 并有效地利用框架所提供的众多安全策略模块。 这样一个使用 MAC 特性的系统, 至少要保证不允许用户任意更改安全属性; 所有的用户实用工具、 程序以及脚本, 必须在所选安全策略模块提供的访问规则的约束下工作; 并且系统管理员应掌握 MAC 访问规则的一切控制权。 细心选择正确的安全策略模块是系统管理员专有的职责。 某些环境也许需要限制网络的访问控制权, 在这种情况下, 使用 &man.mac.portacl.4;、 &man.mac.ifoff.4; 乃至 &man.mac.biba.4; 安全策略模块都会是不错的开始; 在其他情况下, 系统客体也许需要严格的机密性, 像 &man.mac.bsdextended.4; 和 &man.mac.mls.4; 这样的安全策略模块就是为此而设。 对安全策略模块的决定可依据网络配置进行, 也许只有特定的用户才应该被允许使用由 &man.ssh.1; 提供的程序以访问网络或互联网, &man.mac.portacl.4; 安全策略模块应该成为这种情况下的选择。 但对文件系统又该作些什么呢? 是由特定的用户或群组来确定某些目录的访问权限, 抑或是将特定客体设为保密以限制用户或组件访问特定文件? 在文件系统的例子中, 也许访问客体的权限对某些用户是保密的, 但对其他则不是。 比如, 一个庞大的开发团队, 也许会被分成许多由几人组成的小组, A 项目中的开发人员可能不被允许访问 B 项目开发人员创作的客体, 但同时他们还需要访问由 C 项目开发人员创作的客体, 这正符合上述情形。 使用由 MAC 框架提供的不同策略, 用户就可以被分成这种小组, 然后被赋予适当区域的访问权, 由此, 我们就不用担心信息泄漏的问题了。 因此, 每一种安全策略模块都有其处理系统整体安全问题的独特方法。 对安全策略模块的选择应在对安全策略深思熟虑的基础之上进行。 很多情况下, 整体安全策略需要重新修正并在系统上实施。 理解 MAC 框架提供的不同安全策略模块会帮助管理员就其面临的情形选择最佳的策略模块。 &os; 的默认内核并不包含 MAC 框架选项, 因此, 在尝试使用本章中的例子或信息之前, 您应该添加以下内核选项: options MAC 此外, 内核还需要重新编译并且重新安装。 尽管有关 MAC 的许多联机手册中都声明它们可以被编译到内核中, 但对这些策略模块的使用仍可能导致锁死系统的网络及其他功能。 使用 MAC 就像使用防火墙一样, 因此必须要小心防止将系统完全锁死。 在使用 MAC 时, 应该考虑是否能够回退到之前的配置, 在远程进行配置更应加倍小心。 理解 MAC 标签 MAC 标签是一种安全属性, 它可以被应用于整个系统中的主体和客体。 配置标签时, 用户必须能够确切理解其所进行的操作。 客体所具有的属性取决于被加载的策略模块, 不同策略模块解释其属性的方式也差别很大。 由于缺乏理解或无法了解其间联系而导致的配置不当, 会引起意想不到的, 也许是不愿看到的系统异常。 客体上的安全标签是由安全策略模块决定的安全访问控制的一部分。 在某些策略模块中, 标签本身所包含的所有信息足以使其作出决策, 而在其它一些安全策略模块中, 标签则可能被作为一个庞大规则体系的一部分进行处理。 举例来说, 在文件上设定 biba/low 标签, 意味着此标签隶属 Biba 策略模块, 其值为 low 某些在 &os; 中支持标签特性的策略会提供三个预定义的标签, 分别是 low、 high 及 equal 标签。 尽管这些标签在不同安全策略模块中会对访问控制采取不同措施, 但有一点是可以肯定的, 那就是 low 标签表示最低限度的设定, equal 标签会将主体或客体设定为被禁用的或不受影响的, high 标签则会应用 Biba 及 MLS 安全策略模块中允许的最高级别的设定。 在单一标签文件系统的环境中, 同一客体上只会应用一个标签, 于是, 一套访问权限将被应用于整个系统, 这也是很多环境所全部需要的。 另一些应用场景中, 我们需要将多重标签应用于文件系统的客体或主体, 如此一来, 就需要使用 &man.tunefs.8; 的 选项。 在使用 Biba 和 MLS 时可以配置数值标签, 以标示分级控制中的层级程度。 数值的程度可以用来划分或将信息按组分类, 从而只允许同程度或更高程度的组对其进行访问。 多数情况下, 管理员将仅对整个文件系统设定单一标签。 等一下, 这看起来很像 DAC! 但我认为 MAC 确实只将控制权赋予了管理员。 此句话依然是正确的。 在某种程度上, root 是实施控制的用户, 他配置安全策略模块以使用户们被分配到适当的类别/访问 levels 中。 唉, 很多安全策略模块同样可以限制 root 用户。 对于客体的基本控制可能会下放给群组, 但 root 用户随时可以废除或更改这些设定。 这就是如 Biba 及 MLS 这样一些安全策略模块所包含的 hierarchal/clearance 模型。 配置标签 实际上, 有关标签式安全策略模块配置的各种问题都是用基础系统组件实现的。 这些命令为客体和主体配置以及配置的实施和验证提供了一个简便的接口。 所有的配置都应该通过 &man.setfmac.8; 及 &man.setpmac.8; 组件实施。 setfmac 命令是用来对系统客体设置 MAC 标签的, 而 setpmac 则是用来对系统主体设置标签的。 例如: &prompt.root; setfmac biba/high test 若以上命令不发生错误则会直接返回命令提示符, 只有当发生错误时, 这些命令才会给出提示, 这和 &man.chmod.1; 和 &man.chown.8; 命令类似。 某些情况下, 以上命令产生的错误可能是 Permission denied, 一般在受限客体上设置或修改设置时会产生此错误。 其它情况也能导致不同的执行失败。 例如, 文件可能并不隶属于尝试重标签该文件的用户, 客体可能不存在或着是只读的。 文件的某一属性、 进程的某一属性或新的自定义标签值的某一属性, 将使强制式策略不允许进程重标签文件。 例如: 低完整性的用户试图修改高完整性文件的标签, 或者低完整性的用户试图将低完整性文件的标签改为高完整性标签。 系统管理员可使用以下命令解决此问题: &prompt.root; setfmac biba/high test Permission denied &prompt.root; setpmac biba/low setfmac biba/high test &prompt.root; getfmac test test: biba/high 如上所示, 通过 setpmac 对被调用的进程赋予不同的标签, 以覆盖安全策略模块的设置。 getpmac 组件通常用于当前运行的进程, 如 sendmail: 尽管其使用进程编号来替代命令, 其逻辑是相同的。 如果用户试图对其无法访问的文件进行操作, 根据所加载的安全策略模块的规则, 函数 mac_set_link 将会给出 Operation not permitted 的错误提示。 一般标签类型 &man.mac.biba.4;、 &man.mac.mls.4; 及 &man.mac.lomac.4; 策略模块提供了设定简单标签的功能, 其值应该是 high、 equal 及 low 之一。 以下是对这些标签功能的简单描述: low 标签被认为是主体或客体所具有的最低层次的标签设定。 对主体或客体采用此设定, 将阻止其访问标签为 high 的客体或主体。 equal 标签只能被用于不希望受策略控制的客体上。 high 标签对客体或主体采用可能的最高设定。 至于每个策略模块, 每种设定都会产生不同的信息流指令。 阅读联机手册中相关的章节将进一步阐明这些一般标签配置的特点。 标签高级配置 如下所示, 用于 比较方式:区间+区间 (comparison:compartment+compartment) 的标签等级数: biba/10:2+3+6(5:2+3-20:2+3+4+5+6) 其含义为: Biba 策略标签/等级 10区间 2、 3及6: (等级5 ...) 本例中, 第一个等级将被认为是 有效区间有效等级, 第二个等级是低级等级, 最后一个则是高级等级。 大多数配置中并不使用这些设置, 实际上, 它们是为更高级的配置准备的。 当把它们应用在系统客体上时, 则只有当前的等级/区间, 因为它们反映可以实施访问控制的系统中可用的范围, 以及网络接口。 等级和区间, 可以用来在一对主体和客体之间建立一种称为 支配 (dominance) 的关系, 这种关系可能是主体支配客体, 客体支配主体, 互不支配或互相支配。 互相支配 这种情况会在两个标签相等时发生。 由于 Biba 的信息流特性, 您可以设置一系列区间, need to know, 这可能发生于项目之间, 而客体也由其对应的区间。 用户可以使用 susetpmac 来将他们的权限进一步细分, 以便在没有限制的区间里访问客体。 用户和标签设置 用户本身也需要设置标签, 以使其文件和进程能够正确地与系统上定义的安全策略互动, 这是通过使用登录分级在文件 login.conf 中配置的。 每个使用标签的策略模块都会进行用户分级设定。 以下是一个使用所有策略模块的例子: default:\ :copyright=/etc/COPYRIGHT:\ :welcome=/etc/motd:\ :setenv=MAIL=/var/mail/$,BLOCKSIZE=K:\ :path=~/bin:/sbin:/bin:/usr/sbin:/usr/bin:/usr/local/sbin:/usr/local/bin:\ :manpath=/usr/share/man /usr/local/man:\ :nologin=/usr/sbin/nologin:\ :cputime=1h30m:\ :datasize=8M:\ :vmemoryuse=100M:\ :stacksize=2M:\ :memorylocked=4M:\ :memoryuse=8M:\ :filesize=8M:\ :coredumpsize=8M:\ :openfiles=24:\ :maxproc=32:\ :priority=0:\ :requirehome:\ :passwordtime=91d:\ :umask=022:\ :ignoretime@:\ :label=partition/13,mls/5,biba/10(5-15),lomac/10[2]: label 选项用以设定用户分级默认标签, 该标签将由 MAC 执行。 用户绝不会被允许更改该值, 因此其从用户的观点看不是可选的。 当然, 在真实情况的配置中, 管理员不会希望启用所有策略模块。 我们建议您在实施以上配置之前阅读本章的其余部分。 用户也许会在首次登录后更改其标签, 尽管如此, 这仅仅是策略的主观局限性。 上面的例子告诉 Biba 策略, 进程的最小完整性是为5, 最大完整性为15, 默认且有效的标签为10。 进程将以10的完整性运行直至其决定更改标签, 这可能是由于用户使用了 setpmac 命令 (该操作将在登录时被 Biba 限制在一定用户范围之内)。 在所有情况下, 修改 login.conf 之后, 都必须使用 cap_mkdb 重编译登录分级 capability 数据库, 这在接下来的例子和讨论中就会有所体现。 很多站点可能拥有数目可观的用户需要不同的用户分级, 注意到这点是大有裨益的。 深入来说就是需要事先做好计划, 因为管理起来可能十分困难。 在 &os 以后的版本中, 将包含一种将用户映射到标签的新方式, 尽管如此, 这也要到 &os; 5.3 之后的某个时间才能实现。 网络接口和标签设定 也可以在网络接口上配置标签, 以控制进出网络的数据流。 在所有情况下, 策略都会以适应客体的方式运作。 例如, 在 biba 中设置为高的用户, 就不能访问标记为低的网络接口。 可以作为 ifconfig 的参数用于设置网络接口的 MAC 标签。 例如: &prompt.root; ifconfig bge0 maclabel biba/equal 将在 &man.bge.4; 接口上设置 biba/equalMAC 标签。 当使用类似 biba/high(low-high) 这样的标签时, 整个标签应使用引号括起来; 否则将发生错误。 每一个支持标签的策略模块都提供了用于在网络接口上禁用该 MAC 标签的系统控制变量。 将标签设置为 的效果与此类似。 请参见 sysctl 的输出、 策略模块的联机手册, 或本章接下来的内容, 以了解更进一步的详情。 用单一标签还是多重标签? 默认情况下, 系统采用的是 选项。 但这对管理员意味着什么呢? 两种策略之间存在很多的不同之处, 它们在系统安全模型的灵活性方面, 提供了不同的选择。 只允许在每个主体或客体上使用一个标签, 如 biba/high。 这降低了管理的开销, 但也同时降低了支持标签的策略的灵活性。 许多管理员可能更希望在安全策略中使用 选项允许每一个主体或客体拥有各自独立的 MAC 标签, 起作用与标准的、 只允许整个分区上使用一个的 选项类似。 标签选项只有对实现了标签功能的那些策略, 如 Biba、 Lomac、 MLS 以及 SEBSD 才有意义。 很多情况下是不需要设置 的。 考虑下列情形和安全模型: 使用了 MAC 以及许多混合策略的 &os; web-服务器。 这台机器上的整个系统中只需要一个标签, 即 biba/high。 此处的文件系统并不需要 选项, 因为有效的 label 只有一个。 因为这台机器将作为 Web 服务器使用, 因此应该以 biba/low 运行 Web 服务, 以杜绝向上写。 Biba 策略以及它如何运作将在稍后予以讨论, 因此, 如果您感觉前面的说明难以理解的话, 请继续阅读下面的内容, 再回来阅读这些内容就会有较为清晰的认识了。 服务器可以使用设置为 biba/low 的单独的分区, 用于保持其运行环境的状态。 这个例子中还省略了许多内容, 例如, 如何为数据配置访问限制、 参数配置和用户的设置; 它只是为前述的内容提供一个简单的例子。 如果打算使用非标签式策略, 就不需要 选项了。 这些策略包括 seeotheruidsportaclpartition 另一个需要注意的事情是, 在分区上使用 并建立基于 可能会提高系统管理的开销, 因为文件系统中的所有客体都需要指定标签。 这包括对目录、文件, 甚至设备节点。 接下来的命令将在需要使用多个标签的文件系统上设置 。 这一操作只能在单用户模式下完成: &prompt.root; tunefs -l enable / 交换区不需要如此配置。 某些用户可能会在根分区上配置 标志时遇到困难。 如果发生这样的情况, 请复查本章的 规划安全配置 在实施新技术时, 首先进行规划都是非常好的习惯。 在这段时间, 管理员一般都应 进行全面的考察, 这至少应包括下列因素: 方案实施的必要条件; 方案实施的目标; 就实施 MAC 而言, 这包括: 如何在目标系统上对信息和资源进行分类。 需要限制哪类信息或资源的访问, 以及应采用何种限制。 需要使用哪些 MAC 模块来完成这些目标。 尽管重新配置并修改系统资源和安全配置是可行的, 但查找整个系统并修复暨存的文件和用户帐号并不是一件轻而易举的事情。 规划有助于完成无问题且有效的可信系统实施。 事先 对采用 MAC 的可信系统, 以及其配置做试运行十分有益, 因为这对实施的成败至关重要。 草率散漫地配置 MAC 通常是导致失败的祸根。 不同的环境可能会有不同的需求。 建立多层次而完备的安全配置, 可以减少系统正式运转之后所需要的微调。 同样地, 接下来的章节将介绍管理员能够使用的各种不同的模块; 描述它们的使用和配置; 除此之外还有一些关于它们最适合的情景的介绍。 例如, web 服务器可能希望使用 &man.mac.biba.4; 和 &man.mac.bsdextended.4; 策略, 而其他情况下, 例如一台机器上只有少量的本地用户时, &man.mac.partition.4; 则是不错的选择。 模块配置 MAC 框架中的每个模块, 都可以像前述那样连编入内核, 或作为运行时内核模块加载。 推荐的用法, 是通过在 /boot/loader.conf 加入适当的设置, 以便在系统启动时的初始化操作过程中加载这些模块。 接下来的一些小节, 将讨论许多 MAC 模块, 并简单介绍它们的功能。 此外, 这一章还将介绍一些具体环境中的用例。 某些模块支持一种称为标签 (labeling) 的用法, 它可以通过使用类似 允许做这个而不允许做那个 的标签来实现访问控制。 标签配置文件可以控制允许的文件访问方式、 网络通讯, 以及许多其他权限。 在前一节中, 我们已经展示了文件系统中如何通过 标志来启用基于文件或分区的访问控制的方法。 单标签配置在整个系统中只强制一个标签的限制, 这也是 tunefs 选项为什么是 的原因。 MAC seeotheruids 模块 MAC 其他 UID 可见策略 模块名: mac_seeotheruids.ko 对应的内核配置: options MAC_SEEOTHERUIDS 引导选项: mac_seeotheruids_load="YES" &man.mac.seeotheruids.4; 模块模仿并扩展了 security.bsd.see_other_uidssecurity.bsd.see_other_gids sysctl 变量。 这一模块并不需要预先配置标签, 它能够透明地与其他模块协同工作。 加载模块之后, 下列 sysctl 变量可以用来控制其功能: security.mac.seeotheruids.enabled 将启用模块的功能, 并使用默认的配置。 这些默认设置将阻止用户看到其他用户的进程和 socket。 security.mac.seeotheruids.specificgid_enabled 将允许特定的组从这一策略中和面。 要将某些组排除在这一策略之外, 可以用 security.mac.seeotheruids.specificgid=XXX sysctl 变量。 前述例子中, XXX 应替换为希望不受限的组 ID 的数值形式。 security.mac.seeotheruids.primarygroup_enabled 可以用来将特定的主要组排除在策略之外。 使用这一变量时, 不能同时设置 security.mac.seeotheruids.specificgid_enabled MAC bsdextended 模块 MAC 文件系统防火墙策略 模块名: mac_bsdextended.ko 对应的内核配置: options MAC_BSDEXTENDED 引导选项: mac_bsdextended_load="YES" &man.mac.bsdextended.4; 模块能够强制文件系统防火墙策略。 这一模块的策略提供了标准文件系统权限模型的一种扩展, 使得管理员能够建立一种类似防火墙的规则集, 以文件系统层次结构中的保护文件、 实用程序,以及目录。 在尝试访问文件系统客体时, 会遍历规则表, 直至找到匹配的规则, 或到达表尾。 这一行为可以通过修改 &man.sysctl.8; 参数, security.mac.bsdextended.firstmatch_enabled 来进行设置。 与 &os; 中的其他防火墙设置类似, 也可以建一个文件来配置访问控制策略, 并通过 &man.rc.conf.5; 变量的配置在系统引导时加载它。 规则表可以通过工具 &man.ugidfw.8; 工具来输入, 其语法类似 &man.ipfw.8;。 此外还可以通过使用 &man.libugidfw.3; 库来开发其他的工具。 当使用这一模块模块时应极其小心; 不正确的使用将导致文件系统的某些部分无法访问。 例子 在加载了 &man.mac.bsdextended.4; 模块之后, 下列命令可以用来列出当前的规则配置: &prompt.root; ugidfw list 0 slots, 0 rules 如希望的那样, 目前还没有定义任何规则。 这意味着一切都还可以访问。 要创建一个阻止所有用户, 而保持 root 不受影响的规则, 只需运行下面的命令: &prompt.root; ugidfw add subject not uid root new object not uid root mode n - - 在 &os; 5.3 之前的版本中, - add 参数并不存在。 - 此时应使用 set 来代替它。 - 请参见下面的命令例子。 - 这本身可能是一个很糟糕的主意, 因为它会阻止所有用户执行哪怕最简单的命令, 例如 ls。 更富于爱心的规则可能是: &prompt.root; ugidfw set 2 subject uid user1 object uid user2 mode n &prompt.root; ugidfw set 3 subject uid user1 object gid user2 mode n 这将阻止任何 user1user2 的主目录的全部访问, 包括目录列表。 user1 可以用 代替。 这将同样的强制访问控制实施在所有用户, 而不是单个用户上。 root 用户不会受到这些变动的影响。 我们已经给出了 &man.mac.bsdextended.4; 模块如何帮助加强文件系统的大致介绍。 要了解更进一步的信息, 请参见 &man.mac.bsdextended.4; 和 &man.ugidfw.8; 联机手册。 MAC ifoff 模块 MAC 接口屏蔽策略 模块名: mac_ifoff.ko 对应的内核配置: options MAC_IFOFF 引导选项: mac_ifoff_load="YES" &man.mac.ifoff.4; 模块完全是为了立即禁止网络接口, 以及阻止在系统初启时启用网络接口而设计的。 它不需要再系统中配置任何标签, 也不依赖于其他 MAC 模块。 绝大多数特性都可以通过调整下面的 sysctl 来加以控制。 security.mac.ifoff.lo_enabled 表示 启用/禁用 环回接口 (&man.lo.4;) 上的全部流量。 security.mac.ifoff.bpfrecv_enabled 表示 启用/禁用 伯克利包过滤器 (&man.bpf.4;) 接口上的全部流量。 security.mac.ifoff.other_enabled 将在所有其他接口 启用/禁用 网络。 最为常用的 &man.mac.ifoff.4; 用法之一是在不允许引导过程中出现网络流量的环境中监视网络。 另一个建议的用法是撰写一个使用 security/aide 的脚本, 以便自动地在受保护的目录中发现新的或修改过的文件时切断网络。 MAC portacl 模块 MAC 端口访问控制表策略 模块名: mac_portacl.ko 对应的内核配置: MAC_PORTACL 引导选项: mac_portacl_load="YES" &man.mac.portacl.4; 模块可以用来通过一系列 sysctl 变量来限制绑定本地的 TCPUDP 端口。 本质上 &man.mac.portacl.4; 使得 非-root 用户能够绑定到它所指定的特权端口, 也就是那些编号小于 1024 的端口。 在加载之后, 这个模块将在所有的 socket 上启用 MAC 策略。 可以调整下列一些配置: security.mac.portacl.enabled 将完全 启用/禁用 策略。 security.mac.portacl.port_high 将设置为 &man.mac.portacl.4; 所保护的最高端口号。 security.mac.portacl.suser_exempt 如果设置为非零值, 表示将 root 用户排除在策略之外。 security.mac.portacl.rules 将指定实际的 mac_portacl 策略; 请参见下文。 实际的 mac_portacl 策略, 是在 security.mac.portacl.rules sysctl 所指定的一个下列形式的字符串: rule[,rule,...] 其中可以给出任意多个规则。 每一个规则的形式都是: idtype:id:protocol:port。 这里的 idtype 参数可以是 uidgid, 分别表示将 id 参数解释为用户 id 或组 id。 protocol 参数可以用来确定希望应用到 TCPUDP 协议上, 方法是把这一参数设置为 tcpudp。 最后的 port 参数则给出了所指定的用户或组能够绑定的端口号。 由于规则集会直接由内核加以解释, 因此只能以数字形式表示用户 ID、 组 ID, 以及端口等参数。 换言之, 您不能使用用户、 组, 或端口服务的名字来指定它们。 默认情况下, 在 类-&unix; 系统中, 编号小于 1024 的端口只能为特权进程使用或绑定, 也就是那些以 root 身份运行的进程。 为了让 &man.mac.portacl.4; 能够允许非特权进程绑定低于 1024 的端口, 就必须首先禁用标准的 &unix; 限制。 这可以通过把 &man.sysctl.8; 变量 net.inet.ip.portrange.reservedlownet.inet.ip.portrange.reservedhigh 设置为 0 来实现。 请参见下面的例子, 或 &man.mac.portacl.4; 联机手册中的说明, 以了解进一步的信息。 例子 下面的例子更好地展示了前面讨论的内容: &prompt.root; sysctl security.mac.portacl.port_high=1023 &prompt.root; sysctl net.inet.ip.portrange.reservedlow=0 net.inet.ip.portrange.reservedhigh=0 首先我们需要设置使 &man.mac.portacl.4; 管理标准的特权端口, 并禁用普通的 &unix; 绑定限制。 &prompt.root; sysctl security.mac.portacl.suser_exempt=1 您的 root 用户不应因此策略而失去特权, 因此请把 security.mac.portacl.suser_exempt 设置为一个非零的值。 现在您已经成功地配置了 &man.mac.portacl.4; 模块, 并使其默认与 类-&unix; 系统一样运行了。 &prompt.root; sysctl security.mac.portacl.rules=uid:80:tcp:80 允许 UID 为 80 的用户 (正常情况下, 应该是 www 用户) 绑定到 80 端口。 这样 www 用户就能够运行 web 服务器, 而不需要使用 root 权限了。 &prompt.root; sysctl security.mac.portacl.rules=uid:1001:tcp:110,uid:1001:tcp:995 允许 UID 为 1001 的用户绑定 TCP 端口 110 (pop3) 和 995 (pop3s)。 这样用户就能够启动接受来发到 110 和 995 的连接请求的服务了。 MAC partition (分区) 模块 MAC 进程分区策略 模块名: mac_partition.ko 对应的内核配置: options MAC_PARTITION 引导选项: mac_partition_load="YES" &man.mac.partition.4; 策略将把进程基于其 MAC 标签放到特定的 partitions (分区) 中。 这是一种特殊类型的 &man.jail.8;, 但对两者进行比较意义不大。 这个模块应加到 &man.loader.conf.5; 文件中, 以便在启动过程中启用这些规则。 绝大多数这一策略的配置是通过 &man.setpmac.8; 工具来完成的, 它将在后面介绍。 这个策略可以使用下面的 sysctl security.mac.partition.enabled 将启用强制的 MAC 进程 partitions。 当启用了这个规则时, 用户将只能看到他们自己的, 以及其他与他们同处一个 partition 的进程, 而不能使用能够越过 partition 的工具。 例如, insecure class 中的用户, 就无法使用 top 命令, 以及其他需要产生新进程的工具。 要设置或删除 partition 标签中的工具, 需要使用 setpmac &prompt.root; setpmac partition/13 top 这将把 top 命令加入到 insecure class 中的用户的标签集。 注意, 所有由 insecure class 中的用户产生的进程, 仍然会留在 partition/13 标签中。 例子 下面的命令将显示 partition 标签以及进程列表: &prompt.root; ps Zax 接下来的这个命令将允许察看其他用户的进程 partition 标签, 以及那个用户正在运行的进程: &prompt.root; ps -ZU trhodes 除非加载了 &man.mac.seeotheruids.4; 策略, 否则用户就看不到 root 的标签。 非常手工化的实现, 可能会在 /etc/rc.conf 中禁用所有的服务, 并用脚本来按不同的标签来启动它们。 下面的几个策略支持基于所给出的三种标签的完整性设定。 这些选项, 连同它们的限制, 在模块的联机手册中进行了进一步介绍。 MAC 多级 (Multi-Level) 安全模块 MAC 多级 (Multi-Level) 安全策略 模块名: mac_mls.ko 对应的内核配置: options MAC_MLS 引导选项: mac_mls_load="YES" &man.mac.mls.4; 策略, 通过严格控制信息流向来控制系统中主体和客体的访问。 MLS 环境中, 许可 (clearance) 级别会在每一个主体或客体标签上进行设置, 连同对应的区间。 由于这些透明度或敏感度可以有六千多个层次, 因此为每一个主体或客体进行配置将是一件让任何系统管理员都感到头疼的任务。 所幸的是, 这个策略中已经包含了三个 立即可用的 标签。 这些标签是 mls/lowmls/equal 以及 mls/high。 由于这些标签已经在联机手册中进行了介绍, 这里只给出简要的说明: mls/low 标签包含了最低配置, 从而允许其他客体支配它。 任何标记为 mls/low 的客体将是地透明度的, 从而不允许访问更高级别的信息。 此外, 这个标签也阻止拥有较高透明度的客体向其写入或传递信息。 mls/equal 标签应放到不希望使用这一策略的客体上。 mls/high 标签是允许的最高级别透明度。 指定了这个标签的客体将支配系统中的其他客体; 但是, 它们将不允许向较低级别的客体泄露信息。 MLS 提供了: 提供了一些非层次分类的层次安全模型; 固定规则: 不允许向上读, 不允许向下写 (主体可以读取同级或较低级别的客体, 但不能读取高级别的。 类似地, 主体可以向同级或较高级写, 而不能向下写); 保密 (防止不适当的数据透露); 系统设计的基础要点, 是在多个敏感级别之间并行地处理数据 (而不泄露秘密的和机密的信息)。 下列 sysctl 可以用来配置特殊服务和接口: security.mac.mls.enabled 用来启用/禁用 MLS 策略。 security.mac.mls.ptys_equal 将所有的 &man.pty.4; 设备标记为 mls/equal security.mac.mls.revocation_enabled 可以用来在标签转为较低 grade 时撤销客体访问权。 security.mac.mls.max_compartments 可以用来设置客体的最大区间层次; 基本上, 这也就是系统中所允许的最大区间数。 要管理 MLS 标签, 可以使用 &man.setfmac.8; 命令。 要在客体上指定标签, 需要使用下面的命令: &prompt.root; setfmac mls/5 test 下述命令用于取得文件 test 上的 MLS 标签: &prompt.root; getfmac test 以上是对于 MLS 策略提供功能的概要。 另一种做法是在 /etc 中建立一个主策略文件, 并在其中指定 MLS 策略信息, 作为 setfmac 命令的输入。 这种方法, 将在其他策略之后进行介绍。 规划托管敏感性 通过使用多级安全策略模块, 管理员可以规划如何控制敏感信息的流向。 默认情况下, 由于其默认的禁止向上读以及向下写的性质, 系统会默认将所有客体置于较低的状态。 这样, 所有的客体都可以访问, 而管理员则可以在配置阶段慢慢地进行提高信息的敏感度这样的修改。 除了前面介绍的三种基本标签选项之外, 管理员还可以根据需要将用户和用户组进行分组, 以阻止它们之间的信息流。 一些人们比较熟悉的信息限界词汇, 如 机密秘密, 以及 绝密 可以方便您理解这一概念。 管理员也可以简单地根据项目级别建不同的分组。 无论采用何种分类方法, 在实施限制性的策略之前, 都必须首先想好如何进行规划。 这个安全策略模块最典型的用例是电子商务的 web 服务器, 其上的文件服务保存公司的重要信息以及金融机构的情况。 对于只有两三个用户的个人工作站而言, 则可能不甚适用。 + MAC Biba 模块 MAC Biba 完整性策略 模块名: mac_biba.ko 对应的内核配置: options MAC_BIBA 引导选项: mac_biba_load="YES" &man.mac.biba.4; 模块将加载 MAC Biba 策略。 这个策略与 MLS 策略非常类似, 只是信息流的规则有些相反的地方。 通俗地说, 这就是防止敏感信息向下传播, 而 MLS 策略则是防止敏感信息的向上传播; 因而, 这一节的许多内容都可以同时应用于两种策略。 在 Biba 环境中, integrity (完整性) 标签, 将设置在每一个主体或客体上。 这些标签是按照层次级别建立的。 如果客体或主体的级别被提升, 其完整性也随之提升。 被支持的标签是 biba/lowbiba/equal 以及 biba/high; 解释如下: biba/low 标签是客体或主体所能拥有的最低完整性级别。 在客体或主体上设置它, 将阻止其在更高级别客体或主体对其进行的写操作, 虽然读仍被允许。 biba/equal 标签只应在那些希望排除在策略之外的客体上设置。 biba/high 允许向较低标签的客体上写, 但不允许读那些客体。 推荐在那些可能影响整个系统完整性的客体上设置这个标签。 Biba 提供了: 层次式的完整性级别, 并提供了一组非层次式的完整性分类; 固定规则: 不允许向上写, 不允许向下读 (与 MLS 相反)。 主体可以在它自己和较低的级别写, 但不能向更高级别实施写操作。 类似地, 主体也可以读在其自己的, 或更高级别的客体, 但不能读取较低级别的客体; 完整性 (防止对数据进行不正确的修改); 完整性级别 (而不是 MLS 的敏感度级别)。 下列 sysctl 可以用于维护 Biba 策略。 security.mac.biba.enabled 可以用来在机器上启用/禁用是否实施 Biba 策略。 security.mac.biba.ptys_equal 可以用来在 &man.pty.4; 设备上禁用 Biba 策略。 security.mac.biba.revocation_enabled 将在支配主体发生变化时强制撤销对客体的访问权。 要操作系统客体上的 Biba 策略, 需要使用 setfmacgetfmac 命令: &prompt.root; setfmac biba/low test &prompt.root; getfmac test test: biba/low 规划托管完整性 与敏感性不同, 完整性是要确保不受信方不能对信息进行篡改。 这包括了在主体和客体之间传递的信息。 这能够确保用户只能修改甚至访问需要他们的信息。 &man.mac.biba.4; 安全策略模块允许管理员指定用户能够看到和执行的文件和程序, 并确保这些文件能够为系统及用户或用户组所信任, 而免受其他威胁。 在最初的规划阶段, 管理员必须做好将用户分成不同的等级、 级别和区域的准备。 在启动前后, 包括数据以及程序和使用工具在内的客体, 用户都会无法访问。 一旦启用了这个策略模块, 系统将默认使用高级别的标签, 而划分用户级别和等级的工作则交由管理员来进行配置。 与前面介绍的级别限界不同, 好的规划方法可能还包括 topic。 例如, 只允许开发人员修改代码库、 使用源代码编译器, 以及其他开发工具, 而其他用户则分入其他类别, 如测试人员、 设计人员, 以及普通用户, 这些用户可能只拥有读这些资料的权限。 通过其自然的安全控制, 完整性级别较低的主体, 就会无法向完整性级别高的主体进行写操作; 而完整性级别较高的主体, 也不能观察或读较低完整性级别的客体。 通过将客体的标签设为最低级, 可以阻止所有主体对其进行的访问操作。 这一安全策略模块预期的应用场合包括受限的 web 服务器、 开发和测试机, 以及源代码库。 而对于个人终端、 作为路由器的计算机, 以及网络防火墙而言, 它的用处就不大了。 MAC LOMAC 模块 MAC LOMAC 模块名: mac_lomac.ko 对应的内核配置: options MAC_LOMAC 引导选项: mac_lomac_load="YES" MAC Biba 策略不同, &man.mac.lomac.4; 策略只允许在降低了完整性级别之后, 才允许在不破坏完整性规则的前提下访问较低完整性级别的客体。 MAC 版本的 Low-watermark 完整性策略不应与较早的 &man.lomac.4; 实现相混淆, 除了使用浮动的标签来支持主体通过辅助级别区间降级之外, 其工作方式与 Biba 大体相似。 这一次要的区间以 [auxgrade] 的形式出现。 当指定包含辅助级别的 lomac 策略时, 其形式应类似于: lomac/10[2] 这里数字二 (2) 就是辅助级别。 MAC LOMAC 策略依赖于系统客体上存在普适的标签, 这样就允许主体从较低完整性级别的客体读取, 并对主体的标签降级, 以防止其在之后写高完整性级别的客体。 这就是前面讨论的 [auxgrade] 选项, 因此这个策略能够提供更大的兼容性, 而所需要的初始配置也要比 Biba 少。 例子 与 Biba 和 MLS 策略类似; setfmacsetpmac 工具可以用来在系统客体上放置标签: &prompt.root; setfmac /usr/home/trhodes lomac/high[low] &prompt.root; getfmac /usr/home/trhodes lomac/high[low] 注意, 这里的辅助级别是 low, 这一特性只由 MAC LOMAC 策略提供。 MAC Jail 中的 Nagios MAC Jail 中的 Nagios 下面给出了通过多种 MAC 模块, 并正确地配置策略来实现安全环境的例子。 这只是一个测试, 因此不应被看作四海一家的解决之道。 仅仅实现一个策略, 而忽略它不能解决任何问题, 并可能在生产环境中产生灾难性的后果。 在开始这些操作之前, 必须在每一个文件系统上设置 multilabel 选项, 这些操作在这一章开始的部分进行了介绍。 不完成这些操作, 将导致错误的结果。 首先, 请确认已经安装了 net-mngt/nagios-pluginsnet-mngt/nagios, 和 www/apache13 这些 ports, 并对其进行了配置, 且运转正常。 创建一个 insecure (不安全) 用户 Class 首先是在 /etc/login.conf 文件中加入一个新的用户 class: insecure:\ :copyright=/etc/COPYRIGHT:\ :welcome=/etc/motd:\ :setenv=MAIL=/var/mail/$,BLOCKSIZE=K:\ :path=~/bin:/sbin:/bin:/usr/sbin:/usr/bin:/usr/local/sbin:/usr/local/bin :manpath=/usr/share/man /usr/local/man:\ :nologin=/usr/sbin/nologin:\ :cputime=1h30m:\ :datasize=8M:\ :vmemoryuse=100M:\ :stacksize=2M:\ :memorylocked=4M:\ :memoryuse=8M:\ :filesize=8M:\ :coredumpsize=8M:\ :openfiles=24:\ :maxproc=32:\ :priority=0:\ :requirehome:\ :passwordtime=91d:\ :umask=022:\ :ignoretime@:\ :label=biba/10(10-10): 并在 default 用户 class 中加入: :label=biba/high: 一旦完成上述操作, 就需要运行下面的命令来重建数据库: &prompt.root; cap_mkdb /etc/login.conf 引导配置 现在暂时还不要重新启动, 我们还需要在 /boot/loader.conf 中增加下面几行, 以便让模块随系统初始化一同加载: mac_biba_load="YES" mac_seeotheruids_load="YES" 配置用户 使用下面的命令将 root 设为属于默认的 class: &prompt.root; pw usermod root -L default 所有非 root 或系统的用户, 现在需要一个登录 class。 登录 class 是必须的, 否则这些用户将被禁止使用类似 &man.vi.1; 这样的命令。 下面的 sh 脚本应能完成这个工作: &prompt.root; for x in `awk -F: '($3 >= 1001) && ($3 != 65534) { print $1 }' \ /etc/passwd`; do pw usermod $x -L default; done; nagioswww 这两个用户归入不安全 class: &prompt.root; pw usermod nagios -L insecure &prompt.root; pw usermod www -L insecure 创建上下文文件 接下来需要创建一个上下文文件; 您可以把下面的实例放到 /etc/policy.contexts 中。 # This is the default BIBA policy for this system. # System: /var/run biba/equal /var/run/* biba/equal /dev biba/equal /dev/* biba/equal /var biba/equal /var/spool biba/equal /var/spool/* biba/equal /var/log biba/equal /var/log/* biba/equal /tmp biba/equal /tmp/* biba/equal /var/tmp biba/equal /var/tmp/* biba/equal /var/spool/mqueue biba/equal /var/spool/clientmqueue biba/equal # For Nagios: /usr/local/etc/nagios /usr/local/etc/nagios/* biba/10 /var/spool/nagios biba/10 /var/spool/nagios/* biba/10 # For apache /usr/local/etc/apache biba/10 /usr/local/etc/apache/* biba/10 这个策略通过在信息流上设置限制来强化安全。 在这个配置中, 包括 root 和其他用户在内的用户, 都不允许访问 Nagios。 作为 Nagios 一部分的配置文件和进程, 都是完全独立的, 也称为 jailed。 接下来可以用下面的命令将其读入系统: &prompt.root; setfsmac -ef /etc/policy.contexts / &prompt.root; setfsmac -ef /etc/policy.contexts / 随环境不同前述的文件系统布局可能会有所不同; 不过无论如何, 都只能在一个文件系统上运行它。 /etc/mac.conf 文件中的 main 小节需要进行下面的修改: default_labels file ?biba default_labels ifnet ?biba default_labels process ?biba default_labels socket ?biba 启用网络 /boot/loader.conf 中增加下列内容: security.mac.biba.trust_all_interfaces=1 将下述内容加入 rc.conf 中的网络接口配置。 如果主 Internet 配置是通过 DHCP 完成的, 则需要在每次系统启动之后手工执行类似的配置: maclabel biba/equal 测试配置 MAC Configuration Testing (MAC 配置测试) 首先要确认 web 服务以及 Nagios 不会随系统的初始化和重启过程而自动启动。 在此之前, 请在此确认 root 用户不能访问 Nagios 配置目录中的任何文件 如果 root 能够在 /var/spool/nagios 中运行 &man.ls.1;, 则表示配置有误。 如果配置正确的话, 您会收到一条 permission denied 错误信息。 如果一切正常, NagiosApache, 以及 Sendmail 就可以按照适应安全策略的方式启动了。 下面的命令将完成此工作: &prompt.root; cd /etc/mail && make stop && \ setpmac biba/equal make start && setpmac biba/10\(10-10\) apachectl start && \ setpmac biba/10\(10-10\) /usr/local/etc/rc.d/nagios.sh forcestart 再次检查是否一切正常。 如果不是的话, 请检查日志文件和错误信息。 此外, 还可以用 &man.sysctl.8; 来临时禁用 &man.mac.biba.4; 安全策略模块的强制措施, 并象之前那样进行配置和启动服务。 root 用户可以放心大胆地修改安全强制措施, 并编辑配置文件。 下面的命令可以对安全策略进行降级, 并启动一个新的 shell: &prompt.root; setpmac biba/10 csh 要阻止这种情况发生, 就需要配置 &man.login.conf.5; 中许可的命令范围了。 如果 &man.setpmac.8; 尝试执行超越许可范围的命令, 则会返回一个错误, 而不是执行命令。 在这个例子中, 可以把 root 设为 biba/high(high-high) User Lock Down 这个例子针对的是一个相对较小的存储系统, 其用户数少于五十。 用户能够在其上登录, 除了存储数据之外, 还可以访问一些其他资源。 在这个场景中, &man.mac.bsdextended.4; 可以与 &man.mac.seeotheruids.4; 并存, 以达到禁止访问非授权资源, 同时隐藏其他用户的进程的目的。 首先, 在 /boot/loader.conf 中加入: mac_seeotheruids_enabled="YES" 随后, 可以通过下述 rc.conf 变量来启用 &man.mac.bsdextended.4; 安全策略模块: ugidfw_enable="YES" 默认规则保存在 /etc/rc.bsdextended 中, 并在系统初始化时加载; 但是, 其中的默认项可能需要进行一些改动。 因为这台机器只为获得了授权的用户提供服务, 因此除了最后两项之外, 其它内容都应保持注释的状态。 这两项规则将默认强制加载属于用户的系统客体。 在这台机器上添加需要的用户并重新启动。 出于测试的目的, 请在两个控制台上分别以不同的用户身份登录。 运行 ps aux 命令来看看是否能看到其他用户的进程。 此外, 在其他用户的主目录中运行 &man.ls.1; 命令, 如果配置正确, 则这个命令会失败。 不要尝试以 root 用户的身份进行测试, 除非您已经修改了特定的 sysctl 来阻止超级用户的访问。 在添加新用户时, 他们的 &man.mac.bsdextended.4 规则不会自动出现在规则集表中。 要迅速更新规则集, 只需简单地使用 &man.kldunload.8; 和 &man.kldload.8; 工具来卸载并重新加载安全策略模块。 MAC 框架的故障排除 MAC 故障排除 在开发过程中, 有一些用户报告了正常配置下出现的问题。 其中的一些问题如下所示: 无法在 <filename>/</filename> 上启用 <option>multilabel</option> 选项 标志在根 (/) 分区上没有保持启用状态! 看起来每五十个用户中就有一个遇到这样的问题, 当然, 在我们的初始配置过程中也出现过这样的问题。 更进一步的观察使得我相信这个所谓的 bug 是由于文档中不确切的描述, 或对其产生的误解造成的。 无论它是因为什么引发的, 下面的步骤应该能够解决此问题: 编辑 /etc/fstab 并将根分区设置为 , 表示只读。 重新启动并进入单用户模式。 / 上运行 tunefs 重新启动并进入正常的模式。 运行 mount / 并把 /etc/fstab 中的 改回 , 然后再次重新启动。 再次检查来自 mount 的输出, 已确认根文件系统上正确地设置了 在 <acronym>MAC</acronym> 之后无法启动 X11 了 在使用 MAC 建立安全的环境之后, 就无法启动 X 了! 这可能是由于 MAC partition 策略, 或者对某个 MAC 标签策略进行了错误的配置导致的。 要调试这个问题, 请尝试: 检查错误信息; 如果用户是在 insecure class 中, 则 partition 策略就可能导致问题。 尝试将用户的 class 重新改为 default class, 并使用 cap_mkdb 命令重建数据库。 如果这无法解决问题, 则进入第二步。 仔细检查标签策略。 确认针对有问题的用户的策略是正确的, 特别是 X11 应用, 以及 /dev 项。 如果这些都无法解决问题, 将出错消息和对您的环境的描述, 发送到 TrustedBSD 网站上的 TrustedBSD 讨论邮件列表, 或者 &a.questions; 邮件列表。 Error: &man..secure.path.3; cannot stat <filename>.login_conf</filename> 当我试图从 root - 切换到其同中的其他用户时, 出现了错误提示 + 用户切换到其同中的其他用户时, 出现了错误提示 _secure_path: unable to state .login_conf 这个提示通常在用户拥有高于它将要成为的那个用户的 标签设定时出现。 例如, 如果系统上的一个用户 joe 拥有默认的 标签, 而 root 用户拥有 , 它也就不能查看 joe 的主目录, 无论 root 是否使用了 su 来成为 joe。 这种情况下, Biba 完整性模型, 就不会允许 root 查看在较低完整性级别中的客体。 <username>root</username> 用户名被破坏了! 在普通模式, 甚至是单用户模式中, root 不被识别。 whoami 命令返回了 0 (零) 而 su 则提示 who are you?。 到底发生了什么? 标签策略被禁用可能会导致这样的问题, 无论是通过 &man.sysctl.8; 或是卸载了策略模块。 如果打算禁用策略, 或者临时禁用它, 则登录性能数据库需要重新配置, 在其中删除 选项。 仔细检查 login.conf 以确保所有的 选项都已经删除, 然后使用 cap_mkdb 命令来重建数据库。 这种情况也可能在通过策略来限制访问 master.passwd 文件或对应的那个数据库时发生。 这主要是由于管理员修改受某一 label 限制的文件, 而与系统级的通用策略发生了冲突。 这时, 用户信息将由系统直接读取, 而在文件继承了新的 label 之后则会拒绝访问。 此时, 只需使用 &man.sysctl.8; 禁用这一策略, 一切就会恢复正常了。 diff --git a/zh_CN.GB2312/books/handbook/mirrors/chapter.sgml b/zh_CN.GB2312/books/handbook/mirrors/chapter.sgml index 97bd1c6afd..198a07d11c 100644 --- a/zh_CN.GB2312/books/handbook/mirrors/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/mirrors/chapter.sgml @@ -1,3028 +1,3052 @@ 获取 FreeBSD CDROM 和 DVD 发行商 零售盒装产品 可以从下面几个零售商那里买到 FreeBSD 的盒装产品(FreeBSD CD, 附加软件,印刷文档):
CompUSA WWW:
Frys Electronics WWW:
CD 和 DVD 光盘 FreeBSD CD 和 DVD 光盘可以从许多在线零售商那里买到: - -
- BSD Mall by Daemon News - PO Box 161 - Nauvoo, IL 62354 - USA - Phone: +1 866 273-6255 - Fax: +1 217 453-9956 - Email: sales@bsdmall.com - WWW: -
-
-
FreeBSD Mall, Inc. - 3623 Sanford Street - Concord, CA 94520-1405 + 700 Harvest Park Ste F + Brentwood, CA 94513 USA Phone: +1 925 240-6652 Fax: +1 925 674-0821 Email: info@freebsdmall.com WWW:
Dr. Hinner EDV St. Augustinus-Str. 10 D-81825 München Germany Phone: (089) 428 419 WWW:
Ikarios 22-24 rue Voltaire 92000 Nanterre France WWW:
JMC Software Ireland Phone: 353 1 6291282 WWW:
The Linux Emporium Hilliard House, Lester Way Wallingford OX10 9TA United Kingdom Phone: +44 1491 837010 Fax: +44 1491 837016 WWW:
Linux+ DVD Magazine Lewartowskiego 6 Warsaw 00-190 Poland Phone: +48 22 860 18 18 Email: editors@lpmagazine.org WWW:
Linux System Labs Australia 21 Ray Drive Balwyn North VIC - 3104 Australia Phone: +61 3 9857 5918 Fax: +61 3 9857 8974 WWW:
LinuxCenter.Ru Galernaya Street, 55 Saint-Petersburg 190000 Russia Phone: +7-812-3125208 Email: info@linuxcenter.ru WWW:
发行人 如果您是销售商并且想销售 FreeBSD CDROM 产品, 请和发行人联系:
Cylogistics 809B Cuesta Dr., #2149 Mountain View, CA 94040 USA Phone: +1 650 694-4949 Fax: +1 650 694-4953 Email: sales@cylogistics.com WWW:
Ingram Micro 1600 E. St. Andrew Place Santa Ana, CA 92705-4926 USA Phone: 1 (800) 456-8000 WWW:
Kudzu, LLC 7375 Washington Ave. S. Edina, MN 55439 USA Phone: +1 952 947-0822 Fax: +1 952 947-0876 Email: sales@kudzuenterprises.com
LinuxCenter.Ru Galernaya Street, 55 Saint-Petersburg 190000 Russia Phone: +7-812-3125208 Email: info@linuxcenter.ru WWW:
Navarre Corp 7400 49th Ave South New Hope, MN 55428 USA Phone: +1 763 535-8333 Fax: +1 763 535-0341 WWW:
FTP 站点 官方的 FreeBSD 源代码可以从遍布全球的镜像站点 通过匿名 FTP 下载。 站点 有着良好的网络连接并且允许大量的并发连接, 但是 您或许更想找一个 更近的 镜像站点 (特别是当您想进行某种形式的镜像的时候)。 FreeBSD 镜像 站点数据库要比使用手册中的镜像列表更加精确, 因为它从 DNS 中获取信息而不依赖于静态的主机列表。 FreeBSD 可以从下面这些镜像站点通过匿名 FTP 下载。如果您选择了通过匿名 FTP 获取 FreeBSD, 请尽量使用离您比较近的站点。被列为 主镜像站点 的镜像站点一般都有完整的 FreeBSD 文件 (针对每种体系结构的所有当前可用的版本), 您或许从您所在的国家或地区的站点下载会得到更快的下载速度。 每个站点提供了最流行的体系结构的最近的版本而有可能不提供完整的 FreeBSD 存档。所有的站点都提供匿名 FTP 访问而有些站点也提供其他的访问方式。对每个站点可用的访问方式 在其主机名后有所说明。 &chap.mirrors.ftp.inc; + + BitTorrent + + + BitTorrent + + + 基本发行版 CD 的 ISO 镜像也可以通过 BitTorrent 获得。 + 用户下载镜像的 torrent 文件能够在这里找到 http://torrents.freebsd.org:8080 + + BitTorrent 客户端软件可以从这个 port + net-p2p/py-bittorrent + 或预编译的二进制包安装。 + + 在通过 BitTorrent 下载了 ISO 镜像之后, + 你可以照着 burncd + 中的所描述的方法烧录到 CD 或 DVD 介质上。 + + 匿名 CVS <anchor id="anoncvs-intro">概述 CVS 匿名 匿名 CVS(或人们常说的 anoncvs)是由和 FreeBSD 附带的 CVS 实用工具提供的用于和远程的 CVS 代码库同步的一种特性。 尤其是, 它允许 FreeBSD 用户不需要特殊的权限对任何一台 FreeBSD 项目的官方 anoncvs 服务器执行只读的 CVS 操作。 要使用它,简单的设置 CVSROOT 环境变量指向适当的 anoncvs 服务器, 输入 cvs login 命令 并提供广为人知的密码anoncvs,然后使用 &man.cvs.1; 命令像访问任何本地仓库一样来访问它。 cvs login 命令把用来登录 CVS 服务器的密码储存在您的 HOME 目录中一个叫 .cvspass 的文件里。 如果这个文件不存在, 第一次使用 cvs login 的时候可能会出错。 请创建一个空的 .cvspass 文件,然后试试重新登录。 也可以这么说 CVSup 和 anoncvs 服务本质上提供了同样的功能,但是有各种各样 不同的场合可以影响用户对同步方式的选择。简单来说, CVSup 在网络资源利用方面 更加有效,而且是到目前为止在两者之中技术上更成熟的 除了成本方面。要使用 CVSup,在下载任何东西之前 必须首先安装配置特定的客户端, 而且只能用于下载相当大块的 CVSup 称作 collections 相比之下,anoncvs 可以通过 CVS 模块名来从单个文件里检出任何东西并赋给特定的程序 (比如 ls 或者 grep)。 当然,anoncvs 也只适用于对 CVS 仓库的只读操作,所以如果您是想用和 FreeBSD 项目共享的仓库提供本地开发的话, CVSup 几乎是您唯一的选择。 <anchor id="anoncvs-usage">使用匿名 CVS 配置 &man.cvs.1; 使用匿名 CVS 仓库可以简单的设定 CVSROOT 环境变量指向 FreeBSD 项目的 anoncvs 服务器之一。到此书写作为止, 下面的服务器都是可用的: 法国: :pserver:anoncvs@anoncvs.fr.FreeBSD.org:/home/ncvs (pserver (口令是 anoncvs), ssh (没有口令)) 日本: :pserver:anoncvs@anoncvs.jp.FreeBSD.org:/home/ncvs (使用 cvs login 并在提示输入口令时输入 anoncvs.) 台湾地区: :pserver:anoncvs@anoncvs.tw.FreeBSD.org:/home/ncvs (pserver (使用 cvs login 并在提示输入口令时, 输入任意口令。), ssh (无口令)) SSH2 HostKey: 1024 e8:3b:29:7b:ca:9f:ac:e9:45:cb:c8:17:ae:9b:eb:55 /etc/ssh/ssh_host_dsa_key.pub 美国: freebsdanoncvs@anoncvs.FreeBSD.org:/home/ncvs (仅 ssh - 无口令) SSH HostKey: 1024 a1:e7:46:de:fb:56:ef:05:bc:73:aa:91:09:da:f7:f4 root@sanmateo.ecn.purdue.edu SSH2 HostKey: 1024 52:02:38:1a:2f:a8:71:d3:f5:83:93:8d:aa:00:6f:65 ssh_host_dsa_key.pub USA: anoncvs@anoncvs1.FreeBSD.org:/home/ncvs (仅限 ssh2 - 无口令) SSH2 HostKey: 2048 53:1f:15:a3:72:5c:43:f6:44:0e:6a:e9:bb:f8:01:62 /etc/ssh/ssh_host_dsa_key.pub 因为 CVS 实际上允许 检出 曾经存在的 (或者,某种情况下将会存在) FreeBSD 源代码的任意版本, 您需要熟悉 &man.cvs.1; 的版本 () 参数, 以及在 FreeBSD 代码库中可用的值。 有两种标签,修订标签和分支标签。 修订标签特指一个特定的修订版本。含义始终是不变的。 分支标签,另一方面, 指代给定时间给定开发分支的最新修订, 因为分支标签不涉及特定的修订版本, 它明天所代表的含义就可能和今天的不同。 包括了用户可能感兴趣的 修订标签。 请注意, 这些标签并不适用于 Ports Collection, 因为它并不包含多个开发分支。 当您指定一个分支标签,您通常会得到那个开发分支的文件的最新版本。 如果您希望得到一些旧的版本,您可以用 标记制定一个日期。 察看 &man.cvs.1; 手册页了解更多细节。 示例 在这之前强烈建议您通读 &man.cvs.1; 的手册页, 这里有一些简单的例子来展示如何使用匿名 CVS: 从 -CURRENT 检出些东西 (&man.ls.1;): &prompt.user; setenv CVSROOT :pserver:anoncvs@anoncvs.tw.FreeBSD.org:/home/ncvs &prompt.user; cvs login >在提示符处,输入任意密码 password. &prompt.user; cvs co ls 通过 SSH 检出整个 <filename>src/</filename> 代码树: &prompt.user; cvs -d freebsdanoncvs@anoncvs.FreeBSD.org:/home/ncvs co src The authenticity of host 'anoncvs.freebsd.org (128.46.156.46)' can't be established. DSA key fingerprint is 52:02:38:1a:2f:a8:71:d3:f5:83:93:8d:aa:00:6f:65. Are you sure you want to continue connecting (yes/no)? yes Warning: Permanently added 'anoncvs.freebsd.org' (DSA) to the list of known hosts. 检出 6-STABLE 分支中的 &man.ls.1; 版本: &prompt.user; setenv CVSROOT :pserver:anoncvs@anoncvs.tw.FreeBSD.org:/home/ncvs &prompt.user; cvs login 在提示符处,输入任意密码 password。 &prompt.user; cvs co -rRELENG_6 ls 创建 &man.ls.1; 的变化列表(用标准的 diff) &prompt.user; setenv CVSROOT :pserver:anoncvs@anoncvs.tw.FreeBSD.org:/home/ncvs &prompt.user; cvs login 在提示符处,输入任意密码 password。 &prompt.user; cvs rdiff -u -rRELENG_5_3_0_RELEASE -rRELENG_5_4_0_RELEASE ls 找出可以使用的其它的模块名: &prompt.user; setenv CVSROOT :pserver:anoncvs@anoncvs.tw.FreeBSD.org:/home/ncvs &prompt.user; cvs login 在提示符处,输入任意密码 password。 &prompt.user; cvs co modules &prompt.user; more modules/modules 其他资源 下面附加的资源可能对学习 CVS 有帮助: CVS 指南 来自 Cal Poly。 CVS 主页, CVS 开发和支持社区。 CVSweb 是 FreeBSD 项目的 CVS web 界面。 使用 CTM CTM CTM 是保持远程目录树和中央服务器目录树同步的一种方法。 它被开发用于 FreeBSD 的源代码树,虽然其他人随着时间推移会发现它可以用于其他目的。 当前几乎没有,也或者只有很少的文档讲述创建 deltas 的步骤, 所以如果您希望使用 CTM 去做其它事情, 请联系 &a.ctm-users.name; 邮件列表了解更多信息。 为什么我该使用 <application>CTM</application>? CTM 会给您一份 FreeBSD 源代码树的本地副本。 代码树有很多的 flavors 可用。不管您是希望跟踪完整的 CVS 树还是只是一个分支, CTM 都会给您提供信息。 如果您是 FreeBSD 上的一个活跃的开发者,但是缺乏或者不存在 TCP/IP 连接,或者只是希望把变化自动发送给您, CTM 就是适合您的。对于最积极的分支 您将会每天获得三个以上的 deltas。 然而,您应该考虑通过邮件来自动发送。 升级的大小总是保证尽可能的小。 通常小于 5K,也偶然(十分之一可能)会有 10-50K,也不时地有个大的 100K+ 甚至更大的。 您也需要让自己了解直接和开发代码而不是预发行版本打交道的各种警告。这种情况会很显著, 如果您选择了 current 代码的话。强烈建议您阅读和 FreeBSD 保持同步。 使用 <application>CTM</application> 我需要做什么? 您需要两样东西:CTM 程序,还有初始的 deltas 来 feed it(达到 current 级别)。 CTM 程序从版本 2.0 发布以来 已经是 FreeBSD 的一部分了,如果您安装了源代码副本的话, 它位于 /usr/src/usr.sbin/ctm 您喂给 CTMdeltas 可以有两种方式,FTP 或者 email。 如果您有普通的访问 Internet 的 FTP 权限, 那么下面的 FTP 站点支持访问 CTM 或者看看这一小节镜像。 FTP 访问相关的目录并取得 README 文件,从那里开始。 如果您希望通过 email 得到您的 deltas: 订阅一个 CTM 分发列表。 &a.ctm-cvs-cur.name; 支持完整的 CVS 树。 &a.ctm-src-cur.name; 支持最新的开发分支。 &a.ctm-src-4.name; 支持 4.X 发行分支, 等等。。(如果您不知道如何订阅邮件列表, 点击上面的列表名或者到 &a.mailman.lists.link; 点击您希望订阅的列表。 列表页包含了所有必要的订阅指导。) 当您开始接收到您邮件中的 CTM 升级时,您可以使用 ctm_rmail 程序来解压并应用它们。 事实上如果您想要让进程以全自动的形式运行的话,您可以通过在 /etc/aliases 中设置直接使用 ctm_rmail 程序。 查看 ctm_rmail 手册页了解更多细节。 不管您使用什么方法得到 CTM deltas,您都应该订阅 &a.ctm-announce.name; 邮件列表。 以后会有单独的地方提交有关 CTM 系统的操作的公告。 点击上面的邮件列表名并按照指示订阅邮件列表。 第一次使用 <application>CTM</application> 在您开始使用 CTM delta 之前,您需要获得一个起始点。 首先您应该确定您已经有了什么。每个人都可以从一个目录开始。 您必须用一个初始的 空的 delta 来开始您的 CTM 支持树。曾经为了您的便利这些 起始 deltas 被有意的通过 CD 来发行, 然而现在已经不这样做了。 因为代码树有数十兆字节,您应该更喜欢从手头上已经有的东西开始。如果您有一张 -RELEASE CD 光盘,您可以从里面复制或者解压缩一份初始代码出来。 这会节省非常多的数据传输量。 您会发现这些初始的 deltas 名字的数字后面都有个 X (比如 src-cur.3210XEmpty.gz)。 后面加一个 X 的设计符合您的初始 seed 的由来。 Empty 是一个空目录。通常一个基本的从 Empty 开始的转换由 100 个 deltas 构成。顺便说一下,他们都很大!70 到 80 兆字节的 gzip 压缩的数据对于 XEmpty deltas 是很平常的。 一旦您已经选定了一个基本的 delta 开始,您就需要比这个数高的所有的 delta。 在您的日常生活中使用 <application>CTM</application> 要应用 deltas,简单的键入: &prompt.root; cd /where/ever/you/want/the/stuff &prompt.root; ctm -v -v /where/you/store/your/deltas/src-xxx.* CTM 能够理解被 gzip 压缩的 deltas,所以您不需要先 gunzip 他们,这可以节省磁盘空间。 除非觉得整个过程非常可靠, CTM 不会涉及到您的代码树的。您也可以使用 标记来校验 delta, 这样 CTM 就不会涉及代码树; 它会只校验 delta 的完整性看看是否可以安全的用于您的当前代码树。 CTM 还有其他的一些参数, 查看手册页或者源代码了解更多信息。 这真的就是全部的事情了。每次得到一个新的 delta,就通过 CTM 运行它来保证您的代码是最新的。 如果这些 deltas 很难重新下载的话不要删除它们。 有些东西坏掉的时候您会想到保留它们的。 即使您只有软盘,也请考虑使用 fdwrite 来做一份副本。 维持您本地的变动 作为一名开发者喜欢实验,改动代码树中的文件。 CTM 用一种受限的方式支持本地修改:再检查文件 foo 存在之前,首先查找 foo.ctm。如果这个文件存在, CTM 会对它操作而不是 foo 这种行为给我们提供了一种简单的方式来维持本地的改动: 只要复制您计划修改的文件并用 .ctm 的后缀重新命名。 然后就可以自由的修改代码了,CTM 会更新 .ctm 文件到最新版本。 其他有趣的 <application>CTM</application> 选项 正确的找出哪些将被更新 您可以确定变动列表, CTM 可以做到,在您的代码库上使用 CTM 选项。 这很有用如果您想要保存改动的日志, pre- 或者 post- 用各种风格处理修改的文件的纪录, 或者仅仅是想感受一下孩子般的疯狂。 在升级前制作备份 有时您可能想备份将要被 CTM 升级所改动的所有文件。 指定 选项会导致 CTM 备份将要被给定的 CTM delta 改动的所有文件到 backup-file 限定受升级影响的文件 有时您可能对限定一个给定的 CTM 升级的范围感兴趣,也有可能想知道怎样从一列 deltas 中解压缩一部分文件。 您可以通过使用 选项指定过滤规则表达式来控制 CTM 即将对之操作的文件列表。 例如,要从您保存的CTM deltas 集里解压缩出一个最新的 lib/libc/Makefile 文件,运行这个命令: &prompt.root; cd /where/ever/you/want/to/extract/it/ &prompt.root; ctm -e '^lib/libc/Makefile' ~ctm/src-xxx.* 对于每一个在 CTM delta 中指定的文件, 选项按照命令行给定的顺序应用。 文件只有在所有的 被应用之后标记为合格之后 才能被 CTM 操作。 <application>CTM</application> 未来的计划 其中几项: CTM 中使用一些认证方式, 这样来允许察觉冒充的 CTM 补丁。 整理 CTM 的选项, 它们变得杂乱而违反直觉了。 杂项 也有一系列的 ports collection 的 deltas,但是人们对它的兴致还没有那么高。 CTM 镜像 CTM/FreeBSD 可以在下面的镜像站点通过匿名 FTP 下载。如果您选择通过匿名 FTP 获取 CTM, 请试着使用一个离您较近的站点。 如果有问题,请联系 &a.ctm-users.name; 邮件列表。 加利福尼亚州,海湾地区,官方源代码 南非,旧的 deltas 的备份服务器 中国台湾 如果您在您附近找不到镜像或者镜像不完整, 试着使用搜索引擎比如 alltheweb. 使用 CVSup 概述 CVSup 是一个用于从远程服务器主机上的主 CVS 仓库发布和升级源代码树的软件包。 FreeBSD 的源代码维护在加利福尼亚州一台主开发服务器的 CVS 仓库里。 有了 CVSup,FreeBSD 用户可以很容易的保持他们自己的源代码树更新。 CVSup 使用所谓的升级 pull 模式。在 pull 模式下,客户端在需要的时候向服务器端请求更新。 服务器被动的等待客户端的升级请求。 因此所有的升级都是客户端发起的。 服务器决不会发送未请求的升级。用户必须手动运行 CVSup 客户端获取更新, 或者设置一个 cron 作业来让它以固定的规律自动运行。 术语 CVSup用大写字母写正是表示, 代表了完整的软件包。 它的主要组件是运行在每个用户机器上的客户端 cvsup, 和运行在每个 FreeBSD 镜像站点上的服务器端 cvsupd 当您阅读 FreeBSD 文档和邮件列表时,您可能会看见 supSupCVSup 的前身,有着相似的目的。 CVSup 使用很多和 sup 相同的方式, 而且, 它还是用使用和 sup 的兼容的配置文件。 Sup 已经不再被 FreeBSD 项目使用了, 因为 CVSup 既快又有更好的灵活性。 csup 是用 C 语言对 CVSup 软件的重写。 它最大的好处是, 这个程序更快一些, 并且也不需要依赖于 Modula-3 语言, 因此也就不需要安装后者。 另外, 如果您使用 &os; 6.2 或更新版本, 就可以直接使用, 因为它成为了基本系统的一部分。 较早的 &os; 版本的基本系统中并不包含 &man.csup.1;, 但可以通过 net/csup port 或预编译包来安装。 不过需要注意的是, csup 工具并不支持 CVS 模式。 如果您希望对代码库做完整的镜像, 则还是需要使用 CVSup。 假如您决定使用 csup, 则可以跳过安装 CVSup 这一步, 并在文章中余下部分提到的 CVSup 改为 csup 安装 安装 CVSup 最简单的方式就是使用 FreeBSD packages collection 中预编译的 net/cvsup 包。 如果您想从源代码构建 CVSup, 您可以使用 net/cvsup port。但是预先警告一下: net/cvsup port 依赖于 Modula-3 系统,会花费相当的时间和磁盘空间来下载编译。 如果想在没有安装 &xfree86;&xorg; 的计算机, 例如服务器上使用 CVSup, 则只能使用不包含 CVSup GUInet/cvsup-without-gui 如果希望在 &os; 6.1 或更早版本中安装 csup, 则可以从 FreeBSD 的 packages collection 中安装预编译的 net/csup 包; 如果希望自行从源代码编译 csup, 也可以用 net/csup port 来安装。 CVSup 配置 CVSup 的操作被一个叫做 supfile 的配置文件所控制。 在目录 /usr/share/examples/cvsup/ 下面有一些示例的 supfiles supfile 中的信息解答了 CVSup 下面的几个问题: 您想接收 哪些文件? 您想要它们的 哪个版本? 您想从哪里 获取它们? 您想把它们 放在您自己机器的什么地方? 您想把 您的状态文件放在哪? 在下面的章节里,我们通过依次回答这些问题来创建一个典型的 supfile 文件。首先,我们描述一下 supfile 的整体构成。 supfile 是个文本文件。注释用 # 开头,至行尾有效。 空行和只包含注释的行会被忽略。 每个保留行描述一批用户希望接收的文件。 每行以 collection, 由服务器端定义的合理的文件分组,的名字开头。 collection 的名字告诉服务器您想要的文件。 collection 名字结束或者有更多的字段,用空格分隔。 这些字段回答了上面列出的问题。 字段类型有两种:标记字段和值字段。 标记字段由独立的关键字组成,比如, delete 或者 compress。值字段也用关键字开头, 关键字后面跟 = 和第二个词而没有空格。 例如,release=cvs 是一个值字段。 一个典型的 supfile 往往接收多于一个的 collection。创建 supfile 的一种方式是明确的为每一个 collection 指定相关的字段。然而,这样使得 supfile 的行变得特别长,很不方便, 因为 supfile 中的所有 collection 的大部分 字段都是相同的。 CVSup 提供了一个默认机制来避免 这些问题。用特定的伪 collection 名 *default 开头的行可以被用来设置标记和值为 supfile 中随后的 collection 中的默认值。 默认值可以通过为这个 collection 自身指定不同的值来对单个的 collection 覆盖设置, 也可以在 mid-supfile 中通过附加的 *default 行改变或扩充。 知道了这些,我们现在就可以开始创建一个 用于接收和升级 FreeBSD-CURRENT 主源代码树的 supfile 文件了。 您想接收哪些文件? 通过 CVSup 可用的文件组织成叫做 collections 的名称组。 这些可用的 collection 在 随后的章节 中描述。 在这个例子里, 我们希望接收 FreeBSD 系统的完整的主代码树。 有一个单独的大的 collection src-all 让我们完成这个。 创建我们的 supfile 的第一步, 我们简单的列出这些 collection,每个一行(在这个例子里, 只有一行): src-all 您想要他们的 哪个版本? 通过 CVSup,您实际上可以接收 曾经存在的源代码的任何版本。 这是有可能的,因为 cvsupd 服务器直接通过 CVS 仓库工作,那包含了所有的版本。您可以 用 tag= 值字段 指定一个您想要的版本。 仔细的正确指定任何 tag= 字段。有一些 tag 只对特定的 collection 文件合法。 如果您指定了一个不正确的或者 拼写错误的 tag,CVSup 会删除您可能不想删除的文件。 特别地,对 ports-* collection 使用 tag=. tag= 字段在仓库中表示为一个符号标签。 有两种标签,修订标签和分支标签。 修订标签代表一个特定的修订版本。 它的含义是一成不变的。 分支标签,另一方面,代表给定开发线上给定时间的最新修订。 因为分支标签不代表一个特定的修订版本, 它明天的含义就可能和今天的有所不同。 包含了用户可能感兴趣的分支标签。 当在 CVSup 的配置文件中指定标签的时候,必须用 tag= 开头 (RELENG_4 会变成 tag=RELENG_4)。 记住只有 tag=. 可以用于 Ports Collection。 注意像看到的那样正确的输入标签名。 CVSup 不能辨别合法和不合法标签。 如果您拼写错了标签名, CVSup 会像您指定了一个没有任何文件的合法标签一样工作, 那会删除您已经存在的代码。 当您指定一个分支标签的时候,您通常会收到开发线上文件的最新版本。 如果您希望接收一些过时的版本,您可以通过用 值字段指定一个日期来做到。 &man.cvsup.1; 手册页解释了如何来做。 对于我们的示例来说,我们希望接收 FreeBSD-CURRENT。 我们在我们的 supfile 的开头添加这行: *default tag=. 有一个重要的特例, 如果您既没指定 tag= 字段也没指定 date= 字段的情况。这种情况下, 您会收到直接来自于服务器 CVS 仓库的真实的 RCS 文件, 而不是某一特定版本。 开发人员一般喜欢这种操作模式。 通过在他们的系统上维护一份仓库自身的副本, 他们可以浏览修订历史以及检查文件过去的版本。 然而,这个好处是以大量的磁盘空间为代价的。 您想从哪里获取他们? 我们使用 host= 字段来告诉 cvsup 从哪里获取更新。 任何一个 CVSup 镜像站点都可以, 虽然您应该选择一个离您比较近的站点。 在这个例子里我们将使用一个虚拟的 FreeBSD 发布站点, cvsup99.FreeBSD.org *default host=cvsup99.FreeBSD.org 您需要在运行 CVSup 之前把这个改成一个实际存在的站点。 在任何 cvsup 运行的特定时刻, 您都可以在命令行上使用 选项来覆盖主机设置。 您想把它们放在 您自己机器的什么地方? prefix= 字段告诉 cvsup 把接收的文件放在哪里。 在这个例子里,我们把源代码文件直接放进我们的主源代码树, /usr/srcsrc 目录已经隐含在我们选择接收的 collection 里了, 所以正确的写法是: *default prefix=/usr cvsup 在哪里维护它的状态文件? CVSup 客户端在被叫做 base 的目录里维护了几个状态文件。 这些文件帮助 CVSup 更有效的工作, 通过跟踪您已经接收到哪些更新的方式。 我们将使用标准的 base 目录, /var/db *default base=/var/db 如果您的 base 目录还不存在,现在最好创建它。 如果 base 目录不存在,cvsup 客户端会拒绝工作。 其他的 supfile 设置: supfile 中有一些其他选项需要介绍一下: *default release=cvs delete use-rel-suffix compress release=cvs 显示服务器应该从 FreeBSD 的主 CVS 仓库中获取信息。 事实上总是这样的,但是也有可能会超出这个讨论的范围。 deleteCVSup 权限删除文件。 您应该总是指定这个,这样 CVSup 可以保证您的源代码树完全更新。CVSup 很小心的只删除那些不再依赖的文件。 您拥有的任何额外的文件会被严格的保留。 use-rel-suffix 是 ... 不可思议的。 如果您真的想了解它,查看 &man.cvsup.1; 手册页。 否则,就指定而不用担心这个。 compress 启用 gzip 风格的信道压缩。 如果您的网络连接是 T1 或者更快, 您可能不想使用压缩。 否则,它非常有帮助。 把它们放在一起: 这是我们的示例的完整 supfile 文件: *default tag=. *default host=cvsup99.FreeBSD.org *default prefix=/usr *default base=/var/db *default release=cvs delete use-rel-suffix compress src-all <filename>refuse</filename> 文件 像上面提到的,CVSup 使用一种 pull 方法。基本上,这意味着您要连接到 CVSup 服务器,服务器说, 这有些您能下载的东西 ...,然后您的客户端反应好,我要这个, 这个,这个,还有这个。在默认的配置中, CVSup 客户端会取回您在配置文件中选定的 collection 和标签的每个文件。 然而,并不总是您想要的, 尤其是您在同步 docports,或者 www 树 — 大部分人都不能阅读四种或者五种 语言,因此他们不需要下载特定语言的文件。 如果您在 CVSup Ports Collection,您 可以通过单独指定每个 collection 来避免这个 (比如,ports-astrologyports-biology,等等取代简单的说明 ports-all)。然而,因为 docwww 树没有特定语言的 collection,您必须 使用 CVSup 许多极好的特性之一: refuse 文件。 refuse 文件本质上是告诉 CVSup 它不应该从 collection 中取得某些文件;换句话说,它告诉客户端 拒绝 来自服务器的特定的文件。 refuse 文件可以在 base/sup/ 中找到(或者,如果您没有,应该创建一个)。 base 在您的 supfile 中定义; 默认情况下,base 就是 /var/db, 这意味着默认的 refuse 文件就是 /var/db/sup/refuse refuse 文件的格式很简单; 它仅仅包含您不希望下载的文件和目录名。 例如,如果您除了英语和德语之外不会讲其他语言, 而且也不打算阅读德文的文档翻译版本, 则可以把下面这些放在您的 refuse 文件里: doc/bn_* doc/da_* doc/de_* doc/el_* doc/es_* doc/fr_* doc/hu_* doc/it_* doc/ja_* doc/mn_* doc/nl_* doc/no_* doc/pl_* doc/pt_* doc/ru_* doc/sr_* doc/tr_* doc/zh_* 等等其他语言(您可以通过浏览 FreeBSD CVS 仓库找到完整的列表)。 有这个非常有用的特性,那些慢速连接或者要为他们的 Internet 连接按时付费的用户就可以节省宝贵的时间因为他们不再需要 下载那些从来不用的文件。要了解 refuse 文件的更多信息以及其它 CVSup 的优雅的特性,请浏览它的 手册页。 运行 <application>CVSup</application> 您现在准备尝试升级了。命令很简单: &prompt.root; cvsup supfile supfile 的位置当然就是您刚刚创建的 supfile 文件名啦。 如果您在 X11 下面运行,cvsup 会显示一个有一些可以做平常事情的按钮的 GUI 窗口。 按 go 按钮,然后看着它运行。 在这个例子里您将要升级您目前的 /usr/src 树,您将需要 用 root 来运行程序,这样 cvsup 有需要的权限来更新您的文件。 刚刚创建了您的配置文件,又从来没有使用过这个程序, 紧张不安是可以理解的。有一个简单的方法不改变您当前的文件 来做一次试验性的运行。只要在方便的地方创建一个 空目录,并在命令行上作为一个额外的参数说明: &prompt.root; mkdir /var/tmp/dest &prompt.root; cvsup supfile /var/tmp/dest 您指定的目录会作为所有文件更新的目的路径。 CVSup 会检查您在 /usr/src 中的文件,但是不会修改或 删除。任何文件更新都会被放到 /var/tmp/dest/usr/src 里了。 在这种方式下运行 CVSup 也会把它的 base 目录状态文件保持原样。这些文件的新版本 会被写到指定的目录。 因为您有 /usr/src 目录的读权限,所以执行这种试验性的运行 甚至不需要使用 root 用户。 如果您没有运行 X11 或者不喜欢 GUI, 当您运行 cvsup 的时候需要在命令行添加 两个选项: &prompt.root; cvsup -g -L 2 supfile 告诉 CVSup 不要使用 GUI。如果您 没在运行 X11 这个是自动的,否则您必须指定它。 告诉 CVSup 输出所有正在升级的文件的细节。 有三个等级可以选择,从 。默认是 0,意味着除了错误消息 什么都不输出。 还有许多其它的选项可用。想要一个简短的列表, 输入 cvsup -H。要查看更详细的描述, 请查看手册页。 一旦您对升级工作的方式满意了,您就 可以使用 &man.cron.8; 来安排规则的运行 CVSup。 很显然的,您不应该让 CVSup 通过 &man.cron.8; 运行的时候使用它的 GUI。 <application>CVSup</application> 文件 collection CVSup 可用的文件 collection 是分级组织的。 有几个大的 collection,然后它们有分成更小的子 collection。接收一个大的 collection 等同于 接收它的每一个子 collection。 collection 的等级关系在下面列表中通过缩进的使用 反映出来。 最常用的 collection 是 src-all,和 ports-all。其它的 collection 只被有着特定 目的的小部分人使用, 有些站点可能不全部支持。 cvs-all release=cvs FreeBSD 主 CVS 仓库,包含 密码系统的代码。 distrib release=cvs FreeBSD 发行版本和镜像相关的 文件。 doc-all release=cvs FreeBSD 使用手册和其它文档的源代码。 其中不包含 FreeBSD web 站点的文件。 ports-all release=cvs FreeBSD Ports Collection。 如果您不想升级全部的 ports-all(整个 ports 树), 而只是使用下面列出的一个子集, 请确保您总是升级了 ports-base 子 collection! 无论何时在 ports 构建下层构造有所改变的时候都会通过 ports-base 表现出来,事实上某些 改变会很快的被实际的 ports 使用,因此,如果您只升级了 实际的 ports 而他们使用了一些新的特性, 就有极大的可能编译会因一些神秘的错误信息而失败。 这种情况下非常快速的要做的事情 就是确保您的 ports-base 子 collection 更新到 最新。 要自行构建 ports/INDEX, 您 必须 接受 ports-all (完整的 ports tree)。 在部分 ports tree 上构建 ports/INDEX 是不被支持的。 请参见 FAQ ports-accessibility release=cvs 用以帮助残疾用户的软件。 ports-arabic release=cvs 阿拉伯语支持。 ports-archivers release=cvs 存档工具。 ports-astro release=cvs 天文相关的 ports。 ports-audio release=cvs 声音支持。 ports-base release=cvs Ports Collection 构建下部构造 - 位于 /usr/portsMk/Tools/ 子目录的 各种各样的文件。 请查看 重要警告:您应该 总是更新这个 子 collection,无论您更新 FreeBSD Ports Collection 的任何部分的时候! ports-benchmarks release=cvs 基准。 ports-biology release=cvs 生物学。 ports-cad release=cvs 计算机辅助设计工具。 ports-chinese release=cvs 中文语言支持。 ports-comms release=cvs 通信软件。 ports-converters release=cvs 字符编码转换。 ports-databases release=cvs 数据库 ports-deskutils release=cvs 计算机发明前常出现在桌面上的东西。 ports-devel release=cvs 开发工具。 ports-dns release=cvs DNS 相关软件。 ports-editors release=cvs 编辑器 ports-emulators release=cvs 其它操作系统的模拟器 ports-finance release=cvs 货币,金融相关应用程序。 ports-ftp release=cvs FTP 客户端和服务器端工具。 ports-games release=cvs 游戏 ports-german release=cvs 德语支持。 ports-graphics release=cvs 图形图像工具。 ports-hebrew release=cvs 希伯来语支持。 ports-hungarian release=cvs 匈牙利语言支持。 ports-irc release=cvs Internet 多线交谈(IRC)工具。 ports-japanese release=cvs 日语支持。 ports-java release=cvs &java; 工具。 ports-korean release=cvs 韩国语言支持。 ports-lang release=cvs 编程语言。 ports-mail release=cvs 邮件软件。 ports-math release=cvs 数值计算软件。 ports-mbone release=cvs MBone 应用程序。 ports-misc release=cvs 杂样工具。 ports-multimedia release=cvs 多媒体软件。 ports-net release=cvs 网络软件。 ports-net-im release=cvs 即时消息软件。 ports-net-mgmt release=cvs 网管软件。 ports-net-p2p release=cvs 对等网 (peer to peer network) 应用。 ports-news release=cvs USENET 新闻软件。 ports-palm release=cvs Palm 系列软件支持。 ports-polish release=cvs 波兰语支持。 ports-ports-mgmt release=cvs 用于管理 ports 和预编译包的工具。 ports-portuguese release=cvs 葡萄牙语支持。 ports-print release=cvs 打印软件。 ports-russian release=cvs 俄语支持。 ports-science release=cvs 科学计算。 ports-security release=cvs 安全工具。 ports-shells release=cvs 命令行 shell。 ports-sysutils release=cvs 系统实用工具。 ports-textproc release=cvs 文本处理工具(不 包含桌面出版)。 ports-ukrainian release=cvs 乌克兰语支持。 ports-vietnamese release=cvs 越南语支持。 ports-www release=cvs 万维网(WWW)相关软件。 ports-x11 release=cvs 支持 X window 系统的 ports。 ports-x11-clocks release=cvs X11 时钟。 ports-x11-drivers release=cvs X11 驱动程序。 ports-x11-fm release=cvs X11 文件管理器。 ports-x11-fonts release=cvs X11 字体和字体工具。 ports-x11-toolkits release=cvs X11 工具包。 ports-x11-servers release=cvs X11 服务器。 ports-x11-themes release=cvs X11 主题。 ports-x11-wm release=cvs X11 窗口管理器。 projects-all release=cvs FreeBSD 内部项目的代码库。 src-all release=cvs FreeBSD 主代码,包含密码系统的代码。 src-base release=cvs /usr/src 顶层的各式各样的文件。 src-bin release=cvs 但用户模式下可能用到的用户工具 (/usr/src/bin)。 src-cddl release=cvs 采用了 CDDL 授权的实用工具和函数库 (/usr/src/cddl)。 src-contrib release=cvs FreeBSD 项目之外的工具和库,通常在 FreeBSD 中不作修改 (/usr/src/contrib)。 src-crypto release=cvs FreeBSD 项目之外的 密码系统工具和库,通常在 FreeBSD 中不作修改 (/usr/src/crypto)。 src-eBones release=cvs Kerberos 和 DES (/usr/src/eBones)。 没有在当前的 FreeBSD 发行中使用。 src-etc release=cvs 系统配置文件 (/usr/src/etc)。 src-games release=cvs 游戏 (/usr/src/games)。 src-gnu release=cvs GNU 公共许可协议的工具 (/usr/src/gnu)。 src-include release=cvs 头文件 (/usr/src/include)。 src-kerberos5 release=cvs Kerberos5 安全包 (/usr/src/kerberos5)。 src-kerberosIV release=cvs KerberosIV 安全包 (/usr/src/kerberosIV)。 src-lib release=cvs 库 (/usr/src/lib)。 src-libexec release=cvs 通常被其它程序调用的系统程序 (/usr/src/libexec)。 src-release release=cvs 生成 FreeBSD 版本必需的文件 (/usr/src/release)。 src-rescue release=cvs 用于紧急修复的静态联编的程序; 请参见 &man.rescue.8; (/usr/src/rescue)。 src-sbin release=cvs 但用户模式的系统工具 (/usr/src/sbin)。 src-secure release=cvs 密码相关库和命令 (/usr/src/secure)。 src-share release=cvs 跨多个平台的共享的文件 (/usr/src/share)。 src-sys release=cvs 内核 (/usr/src/sys)。 src-sys-crypto release=cvs 内核密码系统代码 (/usr/src/sys/crypto)。 src-tools release=cvs 维护 FreeBSD 的各种各样的工具 (/usr/src/tools)。 src-usrbin release=cvs 用户工具 (/usr/src/usr.bin)。 src-usrsbin release=cvs 系统工具 (/usr/src/usr.sbin)。 www release=cvs FreeBSD WWW 站点的源代码。 distrib release=self CVSup 服务器的 配置文件。用于 CVSup 镜像站点。 gnats release=current GNATS bug 跟踪数据库。 mail-archive release=current FreeBSD 邮件列表存档。 www release=current 预处理过的 FreeBSD WWW 站点文件(不是源文件)。 用于 WWW 镜像站点。 更多信息 CVSup FAQ 以及关于 CVSup 的其他信息, 请查看 CVSup 主页 多数与 FreeBSD 有关的 CVSup 讨论会在 &a.hackers; 进行。 这个软件的新版本会在那里和 &a.announce; 公布。 如果对于 CVSup 有任何问题, 或希望提交 bug 报告, 请参阅 CVSup FAQ CVSup 站点 FreeBSD 的 CVSup 服务器运行于 下列站点: &chap.mirrors.cvsup.inc; CVS 标签 当使用 cvs 或者 CVSup 获取和升级源代码的时候,必须指定一个修订标签。 修订标签代表 &os; 开发的一个特定分支, 或者一个特定的时间点。第一种叫做 分支标签,第二种叫做 版本标签 分支标签 所有这些,除了 HEAD (这个总是 合法标签)以外,只适用于 src/ 树。ports/doc/,和 www/ 树没有分支。 HEAD 主线的符号名,或者说 FreeBSD-CURRENT。 当没有指定修订版本的时候也是默认的。 CVSup 里,这个标签通过 一个 . 来反映出来(不是标点,而是一个 . 字符)。 在 CVS 里,当没有修订标签指定时这是默认的。 在一台 STABLE 机器上检出或者升级到 CURRENT 源代码 通常不是 一个好主意,除非这是您的本意。 RELENG_7 这是 FreeBSD-7.X 的开发分支, 也被称作 FreeBSD 7-STABLE。 RELENG_7_0 FreeBSD-7.0 的发行版分支, 只用于安全公告, 以及其他重要更新。 RELENG_6 这是 FreeBSD-6.X 的开发分支, 也被称作 FreeBSD 6-STABLE。 + + RELENG_6_4 + + + FreeBSD-6.4 的发行版分支, 只用于安全公告, + 以及其他重要更新。 + + + RELENG_6_3 FreeBSD-6.3 的发行版分支, 只用于安全公告, 以及其他重要更新。 RELENG_6_2 FreeBSD-6.2 的发行版分支, 只用于安全公告, 以及其他重要更新。 RELENG_6_1 FreeBSD-6.1 的发行版分支, 只用于安全公告, 以及其他重要更新。 RELENG_6_0 FreeBSD-6.0 的发行版分支, 只用于安全公告, 以及其他重要更新。 RELENG_5 这是 FreeBSD-5.X 的开发分支, 也被称作 FreeBSD 5-STABLE。 RELENG_5_5 FreeBSD-5.5 安全分支。 只被安全公告和其它重要更新使用。 RELENG_5_4 FreeBSD-5.4 安全分支。 只被安全公告和其它重要更新使用。 RELENG_5_3 FreeBSD-5.3 安全分支。 只被安全公告和其它重要更新使用。 RELENG_5_2 针对 FreeBSD-5.2 和 FreeBSD-5.2.1 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_5_1 针对 FreeBSD-5.1 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_5_0 针对 FreeBSD-5.0 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4 FreeBSD-4.X 开发线,也被叫做 FreeBSD-STABLE。 RELENG_4_11 FreeBSD-4.11 发行版, 只被安全公告和其它重要更新使用。 RELENG_4_10 针对 FreeBSD-4.10 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_9 针对 FreeBSD-4.9 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_8 针对 FreeBSD-4.8 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_7 针对 FreeBSD-4.7 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_6 针对 FreeBSD-4.6 和 FreeBSD-4.6.2 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_5 针对 FreeBSD-4.5 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_4 针对 FreeBSD-4.4 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_4_3 针对 FreeBSD-4.3 的发行版本分支,只做 安全咨询和其它紧急的修正。 RELENG_3 FreeBSD-3.X 的开发线,也被叫做 3.X-STABLE。 RELENG_2_2 FreeBSD-2.2.X 的开发线,也被叫做 2.2-STABLE。这个分支过于陈旧了。 版本标签 当一个特定的 &os; 版本发行时, 这些标签代表了一个指定的时间点。发布工程进程在 Release Engineering InformationRelease Process 文档中被详细描述。 src 树使用以 RELENG_ 开头的标签。 portsdoc 树使用以 RELEASE 开头的标签。 最后, www 树上不会有任何特定发行版的标签。 RELENG_7_0_0_RELEASE FreeBSD 7.0 + + RELENG_6_4_0_RELEASE + + + FreeBSD 6.4 + + + RELENG_6_3_0_RELEASE FreeBSD 6.3 RELENG_6_2_0_RELEASE FreeBSD 6.2 RELENG_6_1_0_RELEASE FreeBSD 6.1 RELENG_6_0_0_RELEASE FreeBSD 6.0 RELENG_5_5_0_RELEASE FreeBSD 5.5 RELENG_5_4_0_RELEASE FreeBSD 5.4 RELENG_4_11_0_RELEASE FreeBSD 4.11 RELENG_5_3_0_RELEASE FreeBSD 5.3 RELENG_4_10_0_RELEASE FreeBSD 4.10 RELENG_5_2_1_RELEASE FreeBSD 5.2.1 RELENG_5_2_0_RELEASE FreeBSD 5.2 RELENG_4_9_0_RELEASE FreeBSD 4.9 RELENG_5_1_0_RELEASE FreeBSD 5.1 RELENG_4_8_0_RELEASE FreeBSD 4.8 RELENG_5_0_0_RELEASE FreeBSD 5.0 RELENG_4_7_0_RELEASE FreeBSD 4.7 RELENG_4_6_2_RELEASE FreeBSD 4.6.2 RELENG_4_6_1_RELEASE FreeBSD 4.6.1 RELENG_4_6_0_RELEASE FreeBSD 4.6 RELENG_4_5_0_RELEASE FreeBSD 4.5 RELENG_4_4_0_RELEASE FreeBSD 4.4 RELENG_4_3_0_RELEASE FreeBSD 4.3 RELENG_4_2_0_RELEASE FreeBSD 4.2 RELENG_4_1_1_RELEASE FreeBSD 4.1.1 RELENG_4_1_0_RELEASE FreeBSD 4.1 RELENG_4_0_0_RELEASE FreeBSD 4.0 RELENG_3_5_0_RELEASE FreeBSD-3.5 RELENG_3_4_0_RELEASE FreeBSD-3.4 RELENG_3_3_0_RELEASE FreeBSD-3.3 RELENG_3_2_0_RELEASE FreeBSD-3.2 RELENG_3_1_0_RELEASE FreeBSD-3.1 RELENG_3_0_0_RELEASE FreeBSD-3.0 RELENG_2_2_8_RELEASE FreeBSD-2.2.8 RELENG_2_2_7_RELEASE FreeBSD-2.2.7 RELENG_2_2_6_RELEASE FreeBSD-2.2.6 RELENG_2_2_5_RELEASE FreeBSD-2.2.5 RELENG_2_2_2_RELEASE FreeBSD-2.2.2 RELENG_2_2_1_RELEASE FreeBSD-2.2.1 RELENG_2_2_0_RELEASE FreeBSD-2.2.0 AFS 站点 FreeBSD 的 AFS 服务器运行于下面的站点: 瑞典 文件的路径是: /afs/stacken.kth.se/ftp/pub/FreeBSD/ stacken.kth.se # Stacken Computer Club, KTH, Sweden 130.237.234.43 #hot.stacken.kth.se 130.237.237.230 #fishburger.stacken.kth.se 130.237.234.3 #milko.stacken.kth.se 维护者 ftp@stacken.kth.se rsync 站点 下面的站点让 FreeBSD 可以通过 rsync 协议下载。 rsync 实用程序和 &man.rcp.1; 的工作方式很相像, 但是有更多的选项,使用 rsync 远程更新协议只传输 两份文件的不同之处, 因此能够大幅度的提高网络同步速率。 如果您是 FreeBSD FTP 服务器或者 CVS 仓库的镜像站点, 这一点非常有用。 rsync 套件可以工作在许多种 操作系统上,在 FreeBSD 上,查看 net/rsync port 或者使用 package。 捷克共和国 rsync://ftp.cz.FreeBSD.org/ 可用的 collection: ftp:FreeBSD FTP 服务器的 部分镜像。 FreeBSD:FreeBSD FTP 服务器的 完整镜像。 德国 rsync://grappa.unix-ag.uni-kl.de/ 可用的 collection: freebsd-cvs:完整的 FreeBSD CVS 仓库。 这台服务器也镜像 NetBSD 和 OpenBSD 项目, 还有其他的一些项目的 CVS 仓库。 荷兰 rsync://ftp.nl.FreeBSD.org/ 可用的 collection: vol/4/freebsd-core: 对于 FreeBSD FTP 服务器的完整镜像。 俄罗斯 rsync://cvsup4.ru.FreeBSD.org/ 可用的 collections: FreeBSD-gnats: GNATS bug 跟踪数据库。 台湾地区 (中国) rsync://ftp.tw.FreeBSD.org/ rsync://ftp2.tw.FreeBSD.org/ rsync://ftp6.tw.FreeBSD.org/ 可用的 collection: FreeBSD: FreeBSD FTP 服务器的完整镜像。 英国 rsync://rsync.mirror.ac.uk/ 可用的 collection: ftp.FreeBSD.org: FreeBSD FTP 服务器 的完整镜像。 美国 rsync://ftp-master.FreeBSD.org/ 服务器只供 FreeBSD 主镜像站点使用。 可用的 collection: FreeBSD:FreeBSD FTP 服务器的主要存档。 acl:FreeBSD 主 ACL 列表。 rsync://ftp13.FreeBSD.org/ 可用的 collection: FreeBSD:FreeBSD FTP 服务器的完整 镜像。
diff --git a/zh_CN.GB2312/books/handbook/network-servers/chapter.sgml b/zh_CN.GB2312/books/handbook/network-servers/chapter.sgml index 84519f0d5d..08bb52ee63 100644 --- a/zh_CN.GB2312/books/handbook/network-servers/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/network-servers/chapter.sgml @@ -1,4461 +1,4714 @@ Murray Stokely Reorganized by 网络服务器 概要 本章将覆盖某些在 &unix; 系统上常用的网络服务。话题将会涉及 如何安装、配置、测试和维护多种不同类型的网络服务。本章节中将提 供大量配置文件的样例,期望能够对您有所裨益。 在读完本章之后,您将会知道: 如何管理 inetd 如何设置运行一个网络文件系统。 如何配置一个网络信息服务器以共享用户帐号。 如何通过DHCP自动配置网络。 如何配置一个域名服务器。 如何设置Apache HTTP 服务器。 如何设置文件传输(FTP)服务器。 如何使用Samba为 &windows; 客户端设置文件和打印服务。 如何同步时间和日期,以及如何设置使用NTP协议的时间服务器。 + + 如何配置标准的日志守护进程, + syslogd, 接受远程主机的日志。 + + 在阅读此章节之前,您应当: 理解有关/etc/rc中脚本的基本知识。 熟悉基本网络术语。 懂得如何安装额外的第三方软件()。 Chern Lee Contributed by 为 &os; 6.1-RELEASE 进行了更新, 由 The &os; Documentation Project <application>inetd</application> <quote>超级服务器</quote> 总览 &man.inetd.8; 有时也被称作 Internet 超级服务器, 因为它可以为多种服务管理连接。 当 inetd 收到连接时, 它能够确定连接所需的程序, 启动相应的进程, 并把 socket 交给它 (服务 socket 会作为程序的标准输入、 输出和错误输出描述符)。 使用 inetd 来运行那些负载不重的服务有助于降低系统负载, 因为它不需要为每个服务都启动独立的服务程序。 一般说来, inetd 主要用于启动其它服务程序, 但它也有能力直接处理某些简单的服务, 例如 chargenauth, 以及 daytime 这一节将介绍关于如何通过命令行选项, 以及配置文件 /etc/inetd.conf 来对 inetd 进行配置的一些基础知识。 设置 inetd 是通过 &man.rc.8; 系统启动的。 inetd_enable 选项默认设为 NO, 但可以在安装系统时, 由用户根据需要通过 sysinstall 来打开。 将: inetd_enable="YES" inetd_enable="NO" 写入 /etc/rc.conf 可以启用或禁用系统启动时 inetd 的自动启动。 命令: &prompt.root; /etc/rc.d/inetd rcvar 可以显示目前的设置。 此外, 您还可以通过 inetd_flags 参数来向 inetd 传递额外的其它参数。 命令行选项 与多数服务程序类似, inetd 也提供了为数众多的用以控制其行为的参数。 完整的参数列表如下: inetd 这些参数都可以通过 /etc/rc.confinetd_flags 选项来传给 inetd。 默认情况下, inetd_flags 设为 -wW -C 60, 者表示希望为 inetd 的服务启用 TCP wrapping, 并阻止来自同一 IP 每分钟超过 60 次的请求。 初学的用户可能会很高兴地发现这些选项通常并不需要进行修改, 前面提到的速率限制选项在您的服务器收到过量请求的连接时, 则会有效地发挥作用。 完整的参数列表, 可以在 &man.inetd.8; 联机手册中找到。 -c maximum 指定单个服务的最大并发访问数量,默认为不限。 也可以在此服务的具体配置里面通过改掉。 -C rate 指定单个服务一分钟内能被单个IP地址调用的最大次数, 默认不限。也可以在此服务的具体配置里面通过 改掉。 -R rate 指定单个服务一分钟内能被调用的最大次数,默认为256。 设为0 则允许不限次数调用。 -s maximum 指定同一 IP 同时请求同一服务时允许的最大值; 默认值为不限制。 您可以通过 参数来以服务为单位进行限制。 <filename>inetd.conf</filename> 对于 inetd 的配置, 是通过 /etc/inetd.conf 文件来完成的。 在修改了 /etc/inetd.conf 之后, 可以使用下面的命令来强制 inetd 重新读取配置文件: 重新加载 <application>inetd</application> 配置文件 &prompt.root; /etc/rc.d/inetd reload 配置文件中的每一行都是一个独立的服务程序。 在这个文件中, 前面有 # 的内容被认为是注释。 /etc/inetd.conf 文件的格式如下: service-name socket-type protocol {wait|nowait}[/max-child[/max-connections-per-ip-per-minute[/max-child-per-ip]]] user[:group][/login-class] server-program server-program-arguments 下面是针对 IPv4 的 &man.ftpd.8; 服务的例子: ftp stream tcp nowait root /usr/libexec/ftpd ftpd -l service-name 指明各个服务的服务名。其服务名必须与/etc/services中列出的一致。 这将决定inetd会监听哪个port。 一旦有新的服务需要添加,必须先在/etc/services里面添加。 socket-type 可以是streamdgramraw或者 seqpacketstream 用于基于连接的 TCP 服务;而 dgram 则用于使用 UDP 协议的服务。 protocol 下列之一: 协议 说明 tcp, tcp4 TCP IPv4 udp, udp4 UDP IPv4 tcp6 TCP IPv6 udp6 UDP IPv6 tcp46 Both TCP IPv4 and v6 udp46 Both UDP IPv4 and v6 {wait|nowait}[/max-child[/max-connections-per-ip-per-minute[/max-child-per-ip]]] 指明从inetd 里头调用的服务是否可以自己处理socket. socket类型必须使用, 而stream socket daemons, 由于通常使用多线程方式,应当使用 . 通常把多个 socket 丢给单个服务进程, 而 则 会为每个新的 socket 生成一个子进程。 选项能够配置 inetd 能为本服务派生出的最大子进程数量。 如果某特定服务需要限定最高10个实例, 把/10 放到后头就可以了。 指定 /0 表示不限制子进程的数量。 除了 之外, 还有两个选项可以限制来自同一位置到特定服务的最大连接数。 可以限制特定 IP 地址每分钟的总连接数, 例如, 限制任何 IP 地址每分钟最多连接十次。 则可以限制为某一 IP 地址在任何时候所启动的子进程数量。 这些选项对于防止针对服务器有意或无意的资源耗竭和拒绝服务 (DoS) 攻击十分有用。 这个字段中, 必须指定 两者之一。 而 则是可选项。 流式多线程服务, 并且不配置任何 限制时, 其配置为: nowait 同一个服务, 但希望将服务启动的数量限制为十个时, 则是: nowait/10 同样配置, 限制每个 IP 地址每分钟最多连接二十次, 而同时启动的子进程最多十个, 应写作: nowait/10/20 下面是 &man.fingerd.8; 服务的默认配置: finger stream tcp nowait/3/10 nobody /usr/libexec/fingerd fingerd -s 最后这个例子中, 将子进程数限制为 100 个, 而任意 IP 最多同时建立 5 个连接: nowait/100/0/5 user 该开关指定服务将以什么用户身份运行。一般而言,服务运行身份是 root。基于安全目的,可以看到有些服务以 daemon身份,或者是最小特权的 nobody身份运行。 server-program 当连接到来时,执行服务程序的全路径。如果服务是由 inetd内置提供的,以代替。 server-program-arguments 调用到时,该开关 的值通过argv[0]通过传递给服务而工作。 如果命令行为:mydaemon -d,则 mydaemon -d 开关的值。同样的,如果服务是由inetd 内置提供的,这里还是 Security 随安装时所选的模式不同, 许多 inetd 的服务可能已经默认启用。 如果确实不需要某个特定的服务, 则应考虑禁用它。 在 /etc/inetd.conf 中, 将对应服务的那行前面加上 #, 然后 重新加载 inetd 配置 就可以了。 某些服务, 例如 fingerd, 可能是完全不需要的, 因为它们提供的信息可能对攻击者有用。 某些服务在设计时是缺少安全意识的, 或者有过长或压根没有连接请求的超时机制。 这使得攻击者能够通过缓慢地对这些服务发起连接, 并耗尽可用的资源。 对于这种情况, 设置 限制, 来制约服务的行为是个好办法。 默认情况下,TCP wrapping 是打开的。参考 &man.hosts.access.5; 手册,以获得更多关于在各种 inetd 调用的服务上设置TCP限制的信息。 杂项 daytimetimeechodiscardchargen, 以及 auth 都是由 inetd 提供的内建服务。 auth 服务提供了网络身份服务, 它可以配置为提供不同级别的服务, 而其它服务则通常只能简单的打开或关闭。 参考 &man.inetd.8; 手册获得更多信息。 Tom Rhodes Reorganized and enhanced by Bill Swingle Written by 网络文件系统(NFS) NFS 网络文件系统是FreeBSD支持的文件系统中的一种, 也被称为 NFSNFS允许一个系统在网络上与它人共享目录和文件。通过使用NFS,用户和程序可以象访问本地文件 一样访问远端系统上的文件。 以下是NFS最显而易见的好处: 本地工作站使用更少的磁盘空间,因为通常的数据可以存放在一 台机器上而且可以通过网络访问到。 用户不必在每个网络上机器里头都有一个home目录。Home目录 可以被放在NFS服务器上并且在网络上处处可用。 诸如软驱,CDROM,和 &iomegazip; 之类的存储设备可以在网络上面被别的机器使用。 这可以减少整个网络上的可移动介质设备的数量。 <acronym>NFS</acronym>是如何工作的 NFS 至少包括两个主要的部分: 一台服务器, 以及至少一台客户机, 客户机远程地访问保存在服务器上的数据。 要让这一切运转起来, 需要配置并运行几个程序。 服务器必须运行以下服务: NFS server (服务) 文件服务器 UNIX 客户机 rpcbind mountd nfsd 服务 描述 nfsd NFS,为来自NFS客户端的 请求服务。 mountd NFS挂载服务,处理&man.nfsd.8;递交过来的请求。 rpcbind 此服务允许 NFS 客户程序查询正在被 NFS 服务使用的端口。 客户端同样运行一些进程,比如 nfsiodnfsiod处理来自NFS的请求。 这是可选的,而且可以提高性能,对于普通和正确的操作来说并不是必须的。 参考&man.nfsiod.8;手册获得更多信息。 配置<acronym>NFS</acronym> NFS configuration NFS的配置过程相对简单。这个过程只需要 对/etc/rc.conf文件作一些简单修改。 NFS服务器这端,确认/etc/rc.conf 文件里头以下开关都配上了: rpcbind_enable="YES" nfs_server_enable="YES" mountd_flags="-r" 只要NFS服务被置为enable,mountd 就能自动运行。 在客户端一侧,确认下面这个开关出现在 /etc/rc.conf里头: nfs_client_enable="YES" /etc/exports文件指定了哪个文件系统 NFS应该输出(有时被称为共享)。 /etc/exports里面每行指定一个输出的文件系统和 哪些机器可以访问该文件系统。在指定机器访问权限的同时,访问选项 开关也可以被指定。有很多开关可以被用在这个文件里头,不过不会在这 里详细谈。您可以通过阅读&man.exports.5; 手册来发现这些开关。 以下是一些/etc/exports的例子: NFS export examples 下面是一个输出文件系统的例子, 不过这种配置与您所处的网络环境及其配置密切相关。 例如, 如果要把 /cdrom 输出给与服务器域名相同的三台计算机 (因此例子中只有机器名, 而没有给出这些计算机的域名), 或在 /etc/hosts 文件中进行了这种配置。 标志表示把输出的文件系统置为只读。 由于使用了这个标志, 远程系统在输出的文件系统上就不能写入任何变动了。 /cdrom -ro host1 host2 host3 下面的例子可以输出/home给三个以IP地址方式表示的主机。 对于在没有配置DNS服务器的私有网络里头,这很有用。 此外, /etc/hosts 文件也可以用以配置主机名;参看 &man.hosts.5; 。 标记允许子目录被作为挂载点。 也就是说,客户端可以根据需要挂载需要的目录。 /home -alldirs 10.0.0.2 10.0.0.3 10.0.0.4 下面几行输出 /a ,以便两个来自不同域的客户端可以访问文件系统。 标记授权远端系统上的 root 用户在被输出的文件系统上以root身份进行读写。 如果没有特别指定 -maproot=root 标记, 则即使用户在远端系统上是 root 身份, 也不能修改被输出文件系统上的文件。 /a -maproot=root host.example.com box.example.org 为了能够访问到被输出的文件系统,客户端必须被授权。 请确认客户端在您的 /etc/exports 被列出。 /etc/exports 里头,每一行里面,输出信息和文件系统一一对应。 一个远程主机每次只能对应一个文件系统。而且只能有一个默认入口。比如,假设 /usr 是独立的文件系统。这个 /etc/exports 就是无效的: # Invalid when /usr is one file system /usr/src client /usr/ports client 一个文件系统,/usr, 有两行指定输出到同一主机, client. 解决这一问题的正确的格式是: /usr/src /usr/ports client 在同一文件系统中, 输出到指定客户机的所有目录, 都必须写到同一行上。 没有指定客户机的行会被认为是单一主机。 这限制了你可以怎样输出的文件系统, 但对绝大多数人来说这不是问题。 下面是一个有效输出列表的例子, /usr/exports 是本地文件系统: # Export src and ports to client01 and client02, but only # client01 has root privileges on it /usr/src /usr/ports -maproot=root client01 /usr/src /usr/ports client02 # The client machines have root and can mount anywhere # on /exports. Anyone in the world can mount /exports/obj read-only /exports -alldirs -maproot=root client01 client02 /exports/obj -ro 在修改了 /etc/exports 文件之后, 就必须让 mountd 服务重新检查它, 以便使修改生效。 一种方法是通过给正在运行的服务程序发送 HUP 信号来完成: &prompt.root; kill -HUP `cat /var/run/mountd.pid` 或指定适当的参数来运行 mountd &man.rc.8; 脚本: &prompt.root; /etc/rc.d/mountd onereload 关于使用 rc 脚本的细节, 请参见 另外, 系统重启动可以让 FreeBSD 把一切都弄好。 尽管如此, 重启不是必须的。 以 root 身份执行下面的命令可以搞定一切。 NFS 服务器端: &prompt.root; rpcbind &prompt.root; nfsd -u -t -n 4 &prompt.root; mountd -r NFS 客户端: &prompt.root; nfsiod -n 4 现在每件事情都应该就绪,以备挂载一个远端文件系统。 在这些例子里头, 服务器名字将是:server ,而客户端的名字将是: client。 如果您只打算临时挂载一个远端文件系统或者只是打算作测试配置正确与否, 只要在客户端以 root 身份执行下面的命令: NFS mounting &prompt.root; mount server:/home /mnt 这条命令会把服务端的 /home 目录挂载到客户端的 /mnt 上。 如果配置正确,您应该可以进入客户端的 /mnt 目录并且看到所有服务端的文件。 如果您打算让系统每次在重启动的时候都自动挂载远端的文件系统,把那个文件系统加到 /etc/fstab 文件里头去。下面是例子: server:/home /mnt nfs rw 0 0 &man.fstab.5; 手册里有所有可用的开关。 某些应用程序 (例如 mutt) 需要文件上锁支持才能正常运行。 在使用 NFS 时, 可以用 rpc.lockd 来支持文件上锁功能。 要启用它, 需要在服务器和客户机的 /etc/rc.conf 中加入 (假定两端均已配好了 NFS): rpc_lockd_enable="YES" rpc_statd_enable="YES" 然后使用下述命令启动该程序: &prompt.root; /etc/rc.d/lockd start &prompt.root; /etc/rc.d/statd start 如果并不需要真的在 NFS 客户机和 NFS 服务器间确保上锁的语义, 可以让 NFS 客户机在本地上锁, 方法是使用 &man.mount.nfs.8; 时指定 参数。 请参见 &man.mount.nfs.8; 联机手册以了解更多细节。 实际应用 NFS 有很多实际应用。下面是比较常见的一些: NFS uses 多个机器共享一台CDROM或者其他设备。这对于在多台机器中安装软件来说更加便宜跟方便。 在大型网络中,配置一台中心 NFS 服务器用来放置所有用户的home目录可能会带来便利。 这些目录能被输出到网络以便用户不管在哪台工作站上登录,总能得到相同的home目录。 几台机器可以有通用的/usr/ports/distfiles 目录。 这样的话,当您需要在几台机器上安装port时,您可以无需在每台设备上下载而快速访问源码。 Wylie Stilwell Contributed by Chern Lee Rewritten by 通过 <application>amd</application> 自动地挂接 amd 自动挂接服务 &man.amd.8; (自动挂接服务) 能够自动地在访问时挂接远程的文件系统。 如果文件系统在一段时间之内没有活动, 则会被 amd 自动卸下。 通过使用 amd, 能够提供一个持久挂接以外的选择, 而后者往往需要列入 /etc/fstab amd 通过将自己以 NFS 服务器的形式, 附加到 /host/net 目录上来工作。 当访问这些目录中的文件时, amd 将查找相应的远程挂接点, 并自动地挂接。 /net 用于挂接远程 IP 地址上导出的文件系统, 而 /host 则用于挂接远程主机名上的文件系统。 访问 /host/foobar/usr 中的文件, 相当于告诉 amd 尝试挂接在主机 foobar 上导出的 /usr 通过 <application>amd</application> 来挂接导出的文件系统 您可以通过使用 showmount 命令来查看远程主机上导出的文件系统。 例如, 要查看 foobar 上导出的文件系统, 可以用: &prompt.user; showmount -e foobar Exports list on foobar: /usr 10.10.10.0 /a 10.10.10.0 &prompt.user; cd /host/foobar/usr 如同在前面例子中所看到的, showmount 显示了导出的 /usr。 当进入 /host/foobar/usr 这个目录时, amd 将尝试解析主机名 foobar 并自动地挂接需要的文件系统导出。 amd 可以通过启动脚本来启动, 方法是在 /etc/rc.conf 中加入: amd_enable="YES" 除此之外, 还可以给 amd 通过 amd_flags 选项来传递额外的参数。 默认情况下, amd_flags 为: amd_flags="-a /.amd_mnt -l syslog /host /etc/amd.map /net /etc/amd.map" /etc/amd.map 文件定义了挂接导出文件系统时所使用的默认选项。 /etc/amd.conf 文件, 则定义了更多关于 amd 的高级功能选项。 请参考 &man.amd.8; 和 &man.amd.conf.5; 联机手册, 以了解进一步的情况。 John Lind Contributed by 与其他系统集成时的常见问题 某些特定的 ISA PC 系统上的以太网适配器上有一些限制, 这些限制可能会导致严重的网络问题, 特别是与 NFS 配合使用时。 这些问题并非 FreeBSD 所特有的, 但 FreeBSD 系统会受到这些问题的影响。 这样的问题, 几乎总是在当 (FreeBSD) PC 系统与高性能的工作站, 例如 Silicon Graphics, Inc., 和 Sun Microsystems, Inc. 的工作站联网时发生。 NFS 挂接能够正常工作, 而且一些操作也可能成功, 但服务器会很快变得对客户机不太理会, 虽然对其他客户机的请求仍然能够正常处理。 这种情况通常发生在客户端, 无论它是一个 FreeBSD 系统或是终端。 在许多系统上, 一旦发生了这样的问题, 通常没办法正常地关闭客户机。 唯一的办法通常是让终端复位, 因为这一 NFS 状况没有办法被解决。 尽管 正确的 解决办法, 是为 FreeBSD 系统配备一块高性能的、 适用的以太网适配器, 然而也有办法绕过问题并得到相对满意的结果。 如果 FreeBSD 系统是 服务器, 则在客户机挂接时, 应该指定 。 如果 FreeBSD 系统是 客户机, 则应加入 参数。 这些选项可以通过在对应的 fstab 的第四个字段加入, 以便让客户机能够自动地挂接, 或者通过 &man.mount.8; 的 参数在手工挂接时指定。 还需要注意的是另一个问题, 有时会被误认为是和上面一样的问题。 这个问题多见于 NFS 服务器和客户机在不同的网络上时。 如果是这种情况, 一定要 确定 您的路由器确实把必需的 UDP 信息路由到了目的地, 否则您将什么也做不了。 下面的例子中, fastws 是主机 (接口) 的名字, 它是一台高性能的终端, 而 freebox 是另一台主机 (接口) 的名字, 它是一个使用较低性能的以太网适配器的 FreeBSD 系统。 同时, /sharedfs 将被导出成为 NFS 文件系统 (参见 &man.exports.5;), 而 /project 将是客户机上挂接这一导出文件系统的挂接点。 所有的应用场景中, 请注意附加选项, 例如 以及 可能是您的应用所需要的。 关于 FreeBSD 系统 (freebox) 作为客户机的示范 /etc/fstab 文件, 见于 freebox 之上: fastws:/sharedfs /project nfs rw,-r=1024 0 0 freebox 上手工挂接: &prompt.root; mount -t nfs -o -r=1024 fastws:/sharedfs /project 以 FreeBSD 系统作为服务器的例子, 是 fastws 上的 /etc/fstab freebox:/sharedfs /project nfs rw,-w=1024 0 0 fastws 上手工挂接的命令是: &prompt.root; mount -t nfs -o -w=1024 freebox:/sharedfs /project 几乎所有的 16-位 以太网控制器, 都能够在没有上述读写尺寸限制的情况下正常工作。 对于那些关心到底是什么问题的人, 下面是失败如何发生的解释, 同时这也说明了为什么这是一个无法恢复的问题。 典型情况下, NFS 会使用一个 为单位进行操作, 其尺寸是 8 K (虽然它可能会将操作分成更小尺寸的分片)。 由于最大的以太网包尺寸大约是 1500 字节, 因此 NFS 会分成多个以太网包, 虽然在更高层的代码看来它仍然是一个完整的单元, 并在接收方重新组装, 作为一个整体来 确认。 高性能的工作站, 可以将构成 NFS 单元的包迅速发出, 其节奏会快到标准允许的最大限度。 在容量较小的卡上, 后来的包会冲掉同一单元内的较早的包, 因而整个单元无法被重建或确认。 其结果是, 工作站将超时并重试, 但仍然是完整的 8 K 单元, 这一过程将无休止地重复下去。 如果将单元尺寸限制在以太网包尺寸之下, 我们就能够确保每一个以太网包都能够被独立地接收和确认, 从而避免了上面的死锁情形。 溢出在高性能工作站将数据库投向 PC 系统时仍会发生, 但在更好的网卡上, 能够保证这类溢出不会在每一个 NFS 单元 上都发生。 当出现溢出时, 被影响的单元被重传, 因而此时有很大的机会它将被正确接收、 重组, 并确认。 Bill Swingle Written by Eric Ogren Enhanced by Udo Erdelhoff 网络信息服务 (NIS/YP) 它是什么? NIS Solaris HP-UX AIX Linux NetBSD OpenBSD NIS, 表示网络信息服务 (Network Information Services), 最初由 Sun Microsystems 开发, 用于 &unix; (最初是 &sunos;) 系统的集中管理。 目前, 它基本上已经成为了业界标准; 所有主流的类 &unix; 系统 (&solaris;, HP-UX, &aix;, Linux, NetBSD, OpenBSD, FreeBSD, 等等) 都支持 NIS 黄页 (yellow pages)NIS NIS 也就是人们所熟知的黄页(Yellow Pages), 但由于商标的问题, Sun 将其改名为现在的名字。 旧的术语 (以及 yp), 仍然经常可以看到, 并被广泛使用。 NIS 这是一个基于 RPC 的客户机/服务器系统, 它允许在一个 NIS 域中的一组机器共享一系列配置文件。 这样, 系统管理员就可以配置只包含最基本配置数据的 NIS 客户机系统, 并在单点上增加、 删除或修改配置数据。 Windows NT 尽管实现的内部细节截然不同, 这和 &windowsnt; 域系统非常类似, 以至于可以将两者的基本功能相互类比。 您应该知道的术语和进程 有一系列术语和重要的用户进程将在您在 FreeBSD 上实现 NIS 时用到, 无论是在创建 NIS 服务器, 或作为 NIS 客户机: rpcbind portmap 术语 说明 NIS 域名 NIS 主服务器和所有其客户机 (包括从服务器) 会使用同一 NIS 域名。 和 &windowsnt; 域名类似, NIS 域名与 DNS 无关。 rpcbind 必须运行这个程序, 才能够启用 RPC (远程过程调用, NIS 用到的一种网络协议)。 如果没有运行 rpcbind, 则没有办法运行 NIS 服务器, 或作为 NIS 客户机。 ypbind 绑定(bind) NIS 客户机到它的 NIS 服务器上。 这样, 它将从系统中获取 NIS 域名, 并使用 RPC 连接到服务器上。 ypbind 是 NIS 环境中, 客户机-服务器通讯的核心; 如果客户机上的 ypbind 死掉的话, 它将无法访问 NIS 服务器。 ypserv 只应在 NIS 服务器上运行它; 这是 NIS 的服务器进程。 如果 &man.ypserv.8; 死掉的话, 则服务器将不再具有响应 NIS 请求的能力 (此时, 如果有从服务器的话, 则会接管操作)。 有一些 NIS 的实现 (但不是 FreeBSD 的这个) 的客户机上, 如果之前用过一个服务器, 而那台服务器死掉的话, 并不尝试重新连接到另一个服务器。 通常, 发生这种情况时, 唯一的办法就是重新启动服务器进程 (或者, 甚至重新启动服务器) 或客户机上的 ypbind 进程。 rpc.yppasswdd 另一个只应在 NIS 主服务器上运行的进程; 这是一个服务程序, 其作用是允许 NIS 客户机改变它们的 NIS 口令。 如果没有运行这个服务, 用户将必须登录到 NIS 主服务器上, 并在那里修改口令。 它是如何工作的? 在 NIS 环境中, 有三种类型的主机: 主服务器, 从服务器, 以及客户机。 服务器的作用是充当主机配置信息的中央数据库。 主服务器上保存着这些信息的权威副本, 而从服务器则是保存这些信息的冗余副本。 客户机依赖于服务器向它们提供这些信息。 许多文件的信息可以通过这种方式来共享。 通常情况下, master.passwdgroup, 以及 hosts 是通过 NIS 分发的。 无论什么时候, 如果客户机上的某个进程请求这些本应在本地的文件中的资料的时候, 它都会向所绑定的 NIS 服务器发出请求, 而不使用本地的版本。 机器类型 NIS 主服务器 一台 NIS 主服务器。 这台服务器, 和 &windowsnt; 域控制器类似, 会维护所有 NIS 客户机所使用的文件。 passwdgroup, 以及许多其他 NIS 客户机所使用的文件, 都被存放到主服务器上。 可以将一台 NIS 主服务器用在多个 NIS 域中。 然而, 本书不打算对这种配置进行介绍, 因为这种配置, 通常只出现在小规模的 NIS 环境中。 NIS 从服务器 NIS 从服务器。 这一概念, 与 &windowsnt; 的备份域控制器类似。 NIS 从服务器, 用于维护 NIS 主服务器的数据文件副本。 NIS 从服务器提供了一种冗余, 这在许多重要的环境中是必需的。 此外, 它也帮助减轻了主服务器的负荷: NIS 客户机总是挂接到最先响应它们的 NIS 服务器上, 而这也包括来自从服务器的响应。 NIS 客户机 NIS 客户机。 NIS 客户机, 和多数 &windowsnt; 工作站类似, 通过 NIS 服务器 (或对于 &windowsnt; 工作站, 则是 &windowsnt; 域控制器) 来完成登录时的身份验证过程。 使用 NIS/YP 这一节将通过实例介绍如何配置 NIS 环境。 规划 假定您正在管理大学中的一个小型实验室。 在这个实验室中, 有 15 台 FreeBSD 机器, 目前尚没有集中的管理点; 每一台机器上有自己的 /etc/passwd/etc/master.passwd。 这些文件通过人工干预的方法来保持与其他机器上版本的同步; 目前, 如果您在实验室中增加一个用户, 将不得不在所有 15 台机器上手工执行 adduser 命令。 毋庸置疑, 这一现状必须改变, 因此您决定将整个实验室转为使用 NIS, 并使用两台机器作为服务器。 因此, 实验室的配置应该是这样的: 机器名 IP 地址 机器的角色 ellington 10.0.0.2 NIS 主服务器 coltrane 10.0.0.3 NIS 从服务器 basie 10.0.0.4 教员工作站 bird 10.0.0.5 客户机 cli[1-11] 10.0.0.[6-17] 其他客户机 如果您是首次配置 NIS, 仔细思考如何进行规划就十分重要。 无论您的网络的大小如何, 都必须进行几个决策。 选择 NIS 域名 NIS 域名 这可能不是您过去使用的 域名(domainname)。 它的规范的叫法, 应该是 NIS 域名。 当客户机广播对此信息的请求时, 它会将 NIS 域的名字作为请求的一部分发出。 这样, 统一网络上的多个服务器, 就能够知道谁应该回应请求。 您可以把 NIS 域名想象成以某种方式相关的一组主机的名字。 一些机构会选择使用它们的 Internet 域名来作为 NIS 域名。 并不推荐这样做, 因为在调试网络问题时, 这可能会导致不必要的困扰。 NIS 域名应该是在您网络上唯一的, 并且有助于了解它所描述的到底是哪一组机器。 例如对于 Acme 公司的美工部门, 可以考虑使用 acme-art 这样的 NIS 域名。 在这个例子中, 您使用的域名是 test-domain SunOS 然而, 某些操作系统 (最著名的是 &sunos;) 会使用其 NIS 域名作为 Internet 域名。 如果您的网络上存在包含这类限制的机器, 就 必须 使用 Internet 域名来作为您的 NIS 域名。 服务器的物理要求 选择 NIS 服务器时, 需要时刻牢记一些东西。 NIS 的一个不太好的特性就是其客户机对于服务器的依赖程度。 如果客户机无法与其 NIS 域的服务器联系, 则这台机器通常会陷于不可用的状态。 缺少用户和组信息, 会使绝大多数系统进入短暂的冻结状态。 基于这样的考虑, 您需要选择一台不经常重新启动, 或用于开发的机器来承担其责任。 如果您的网络不太忙, 也可以使用运行着其他服务的机器来安放 NIS 服务, 只是需要注意, 一旦 NIS 服务器不可用, 则 所有 的 NIS 客户机都会受到影响。 NIS 服务器 所有的 NIS 信息的正规版本, 都被保存在一台单独的称作 NIS 主服务器的机器上。 用于保存这些信息的数据库, 称为 NIS 映射(map)。 在 FreeBSD 中, 这些映射被保存在 /var/yp/[domainname] 里, 其中 [domainname] 是提供服务的 NIS 域的名字。 一台 NIS 服务器, 可以同时支持多个域, 因此可以建立很多这样的目录, 所支撑一个域对应一个。 每一个域都会有一组独立的映射。 NIS 主和从服务器, 通过 ypserv 服务程序来处理所有的 NIS 请求。 ypserv 有责任接收来自 NIS 客户机的请求, 翻译请求的域, 并将名字映射为相关的数据库文件的路径, 然后将来自数据库的数据传回客户机。 配置 NIS 主服务器 NIS 服务器配置 配置主 NIS 服务器相对而言十分的简单, 而其具体步骤则取决于您的需要。 FreeBSD 提供了一步到位的 NIS 支持。 您需要做的全部事情, 只是在 /etc/rc.conf 中加入一些配置, 其他工作会由 FreeBSD 完成。 nisdomainname="test-domain" 这一行将在网络启动 (例如重新启动) 时, 把 NIS 域名配置为 test-domain nis_server_enable="YES" 这将要求 FreeBSD 在网络子系统启动之后立即启动 NIS 服务进程。 nis_yppasswdd_enable="YES" 这将启用 rpc.yppasswdd 服务程序, 如前面提到的, 它允许用户在客户机上修改自己的 NIS 口令。 随 NIS 配置的不同, 可能还需要增加其他一些项目。 请参见 关于 NIS 服务器同时充当 NIS 客户机 这一节, 以了解进一步的情况。 现在, 所需要做的最后的工作是以超级用户身份执行 /etc/netstart 命令。 这将依据 /etc/rc.conf 为您配置好所有的东西。 初始化 NIS 映射 NIS 映射 NIS 映射 是一些数据库文件, 它们位于 /var/yp 目录中。 这些文件基本上都是根据 NIS 主服务器的 /etc 目录自动生成的, 唯一的例外是: /etc/master.passwd 文件。 一般来说, 您会有非常充分的理由不将 root 以及其他管理帐号的口令发到所有 NIS 域上的服务器上。 因此, 在开始初始化 NIS 映射之前, 我们应该: &prompt.root; cp /etc/master.passwd /var/yp/master.passwd &prompt.root; cd /var/yp &prompt.root; vi master.passwd 这里, 删除掉和系统有关的帐号对应的项 (binttykmemgames, 等等), 以及其他不希望被扩散到 NIS 客户机的帐号 (例如 root 和任何其他 UID 0 (超级用户) 的帐号)。 确认 /var/yp/master.passwd 这个文件是同组用户, 以及其他用户不可读的 (模式 600)! 如果需要的话, 用 chmod 命令来改它。 Tru64 UNIX 完成这些工作之后, 就可以初始化 NIS 映射了! FreeBSD 提供了一个名为 ypinit 的脚本来帮助您完成这项工作 (详细信息, 请见其联机手册)。 请注意, 这个脚本在绝大多数 &unix; 操作系统上都可以找到, 但并不是所有操作系统的都提供。 在 Digital UNIX/Compaq Tru64 UNIX 上它的名字是 ypsetup。 由于我们正在生成的是 NIS 主服务器的映射, 因此应该使用 ypinit 参数。 如果已经完成了上述步骤, 要生成 NIS 映射, 只需执行: ellington&prompt.root; ypinit -m test-domain Server Type: MASTER Domain: test-domain Creating an YP server will require that you answer a few questions. Questions will all be asked at the beginning of the procedure. Do you want this procedure to quit on non-fatal errors? [y/n: n] n Ok, please remember to go back and redo manually whatever fails. If you don't, something might not work. At this point, we have to construct a list of this domains YP servers. rod.darktech.org is already known as master server. Please continue to add any slave servers, one per line. When you are done with the list, type a <control D>. master server : ellington next host to add: coltrane next host to add: ^D The current list of NIS servers looks like this: ellington coltrane Is this correct? [y/n: y] y [..output from map generation..] NIS Map update completed. ellington has been setup as an YP master server without any errors. ypinit 应该会根据 /var/yp/Makefile.dist 来创建 /var/yp/Makefile 文件。 创建完之后, 这个文件会假定您正在操作只有 FreeBSD 机器的单服务器 NIS 环境。 由于 test-domain 还有一个从服务器, 您必须编辑 /var/yp/Makefile ellington&prompt.root; vi /var/yp/Makefile 应该能够看到这样一行, 其内容是 NOPUSH = "True" (如果还没有注释掉的话)。 配置 NIS 从服务器 NIS 从服务器 配置 NIS 从服务器, 甚至比配置主服务器还要简单。 登录到从服务器上, 并按照前面的方法, 编辑 /etc/rc.conf 文件。 唯一的区别是, 在运行 ypinit 时需要使用 参数。 这里的 选项, 同时要求提供 NIS 主服务器的名字, 因此我们的命令行应该是: coltrane&prompt.root; ypinit -s ellington test-domain Server Type: SLAVE Domain: test-domain Master: ellington Creating an YP server will require that you answer a few questions. Questions will all be asked at the beginning of the procedure. Do you want this procedure to quit on non-fatal errors? [y/n: n] n Ok, please remember to go back and redo manually whatever fails. If you don't, something might not work. There will be no further questions. The remainder of the procedure should take a few minutes, to copy the databases from ellington. Transferring netgroup... ypxfr: Exiting: Map successfully transferred Transferring netgroup.byuser... ypxfr: Exiting: Map successfully transferred Transferring netgroup.byhost... ypxfr: Exiting: Map successfully transferred Transferring master.passwd.byuid... ypxfr: Exiting: Map successfully transferred Transferring passwd.byuid... ypxfr: Exiting: Map successfully transferred Transferring passwd.byname... ypxfr: Exiting: Map successfully transferred Transferring group.bygid... ypxfr: Exiting: Map successfully transferred Transferring group.byname... ypxfr: Exiting: Map successfully transferred Transferring services.byname... ypxfr: Exiting: Map successfully transferred Transferring rpc.bynumber... ypxfr: Exiting: Map successfully transferred Transferring rpc.byname... ypxfr: Exiting: Map successfully transferred Transferring protocols.byname... ypxfr: Exiting: Map successfully transferred Transferring master.passwd.byname... ypxfr: Exiting: Map successfully transferred Transferring networks.byname... ypxfr: Exiting: Map successfully transferred Transferring networks.byaddr... ypxfr: Exiting: Map successfully transferred Transferring netid.byname... ypxfr: Exiting: Map successfully transferred Transferring hosts.byaddr... ypxfr: Exiting: Map successfully transferred Transferring protocols.bynumber... ypxfr: Exiting: Map successfully transferred Transferring ypservers... ypxfr: Exiting: Map successfully transferred Transferring hosts.byname... ypxfr: Exiting: Map successfully transferred coltrane has been setup as an YP slave server without any errors. Don't forget to update map ypservers on ellington. 现在应该会有一个叫做 /var/yp/test-domain 的目录。 在这个目录中, 应该保存 NIS 主服务器上的映射的副本。 接下来需要确定这些文件都及时地同步更新了。 在从服务器上, 下面的 /etc/crontab 项将帮助您确保这一点: 20 * * * * root /usr/libexec/ypxfr passwd.byname 21 * * * * root /usr/libexec/ypxfr passwd.byuid 这两行将强制从服务器将映射与主服务器同步。 由于主服务器会尝试确保所有其 NIS 映射的变动都知会从服务器, 因此这些项并不是绝对必需的, 尽管如此, 强制更新能够保证这些对依赖于服务器的系统至关重要的口令信息及时地同步。 同时, 在繁忙的网络上, 有时也会出现映射同步更新不完全的情况。 现在, 在从服务器上执行 /etc/netstart, 就可以启动 NIS 服务了。 NIS 客户机 NIS 客户机会通过 ypbind 服务程序来与特定的 NIS 服务器建立一种称作绑定的联系。 ypbind 会检查系统的默认域 (这是通过 domainname 命令来设置的), 并开始在本地网络上广播 RPC 请求。 这些请求会指定 ypbind 尝试绑定的域名。 如果已经配置了服务器, 并且这些服务器接到了广播, 它将回应 ypbind, 后者则记录服务器的地址。 如果有多个可用的服务器 (例如一个主服务器, 加上多个从服务器), ypbind 将使用第一个响应的地址。 从这一时刻开始, 客户机会把所有的 NIS 请求直接发给那个服务器。 ypbind 偶尔会 ping 服务器以确认其仍然在正常运行。 如果在合理的时间内没有得到响应, 则 ypbind 会把域标记为未绑定, 并再次发起广播, 以期找到另一台服务器。 设置 NIS 客户机 NIS 客户机配置 配置一台 FreeBSD 机器作为 NIS 客户机是非常简单的。 编辑 /etc/rc.conf 文件, 并在其中加上下面几行, 以设置 NIS 域名, 并在网络启动时启动 ypbind nisdomainname="test-domain" nis_client_enable="YES" 要从 NIS 服务器导入所有的口令项, 需要从您的 /etc/master.passwd 文件中删除所有用户, 并使用 vipw 在这个文件的最后一行加入: +::::::::: 这一行将让 NFS 服务器的口令映射中的帐号能够登录。 也有很多修改这一行来配置 NIS 客户机的办法。 请参见稍后的 netgroups 小节 以了解进一步的情况。 要了解更多信息, 可以参阅 O'Reilly 的 Managing NFS and NIS 这本书。 需要至少保留一个本地帐号 (也就是不通过 NIS 导入) 在您的 /etc/master.passwd 文件中, 而这个帐号应该是 wheel 组的成员。 如果 NIS 发生不测, 这个帐号可以用来远程登录, 成为 root, 并修正问题。 要从 NIS 服务器上导入组信息, 需要在 /etc/group 文件末尾加入: +:*:: 完成这些步骤之后, 就应该可以通过运行 ypcat passwd 来看到 NIS 服务器的口令映射了。 NIS 的安全性 基本上, 任何远程用户都可以发起一个 RPC 到 &man.ypserv.8; 并获得您的 NIS 映射的内容, 如果远程用户了解您的域名的话。 要避免这类未经授权的访问, &man.ypserv.8; 支持一个称为 securenets 的特性, 用以将访问限制在一组特定的机器上。 在启动过程中, &man.ypserv.8; 会尝试从 /var/yp/securenets 中加载 securenet 信息。 这个路径随 参数改变。 这个文件包含了一些项, 每一项中包含了一个网络标识和子网掩码, 中间用空格分开。 以 # 开头的行会被认为是注释。 示范的 securenets 文件如下所示: # allow connections from local host -- mandatory 127.0.0.1 255.255.255.255 # allow connections from any host # on the 192.168.128.0 network 192.168.128.0 255.255.255.0 # allow connections from any host # between 10.0.0.0 to 10.0.15.255 # this includes the machines in the testlab 10.0.0.0 255.255.240.0 如果 &man.ypserv.8; 接到了来自匹配上述任一规则的地址的请求, 则它会正常处理请求。 反之, 则请求将被忽略, 并记录一条警告信息。 如果 /var/yp/securenets 文件不存在, 则 ypserv 会允许来自任意主机的请求。 ypserv 程序也支持 Wietse Venema 的 TCP Wrapper 软件包。 这样, 管理员就能够使用 TCP Wrapper 的配置文件来代替 /var/yp/securenets 完成访问控制。 尽管这两种访问控制机制都能够提供某种程度的安全, 但是, 和特权端口检查一样, 它们无法避免 IP 伪造 攻击。 您的防火墙应该阻止所有与 NIS 有关的访问。 使用 /var/yp/securenets 的服务器, 可能会无法为某些使用陈旧的 TCP/IP 实现的 NIS 客户机服务。 这些实现可能会在广播时, 将主机位都设置为 0, 或在计算广播地址时忽略子网掩码。 尽管这些问题可以通过修改客户机的配置来解决, 其他一些问题也可能导致不得不淘汰那些客户机系统, 或者不使用 /var/yp/securenets 在使用陈旧的 TCP/IP 实现的系统上, 使用 /var/yp/securenets 是一个非常糟糕的做法, 因为这将导致您的网络上的 NIS 丧失大部分功能。 TCP Wrappers 使用 TCP Wrapper 软件包, 会导致您的 NIS 服务器的响应延迟增加。 而增加的延迟, 则可能会导致客户端程序超时, 特别是在繁忙的网络或者很慢的 NIS 服务器上。 如果您的某个客户机因此而产生一些异常, 则应将这些客户机变为 NIS 从服务器, 并强制其绑定自己。 不允许某些用户登录 在我们的实验室中, basie 这台机器, 是一台教员专用的工作站。 我们不希望将这台机器拿出 NIS 域, 而主 NIS 服务器上的 passwd 文件, 则同时包含了教员和学生的帐号。 这时应该怎么做? 有一种办法来禁止特定的用户登录机器, 即使他们身处 NIS 数据库之中。 要完成这一工作, 只需要在客户机的 /etc/master.passwd 文件中加入一些 -username 这样的项, 其中, username 是希望禁止登录的用户名。 一般推荐使用 vipw 来完成这个工作, 因为 vipw 会对您在 /etc/master.passwd 文件上所作的修改进行合法性检查, 并在编辑结束时重新构建口令数据库。 例如, 如果希望禁止用户 bill 登录 basie, 我们应该: basie&prompt.root; vipw [在末尾加入 -bill, 并退出] vipw: rebuilding the database... vipw: done basie&prompt.root; cat /etc/master.passwd root:[password]:0:0::0:0:The super-user:/root:/bin/csh toor:[password]:0:0::0:0:The other super-user:/root:/bin/sh daemon:*:1:1::0:0:Owner of many system processes:/root:/sbin/nologin operator:*:2:5::0:0:System &:/:/sbin/nologin bin:*:3:7::0:0:Binaries Commands and Source,,,:/:/sbin/nologin tty:*:4:65533::0:0:Tty Sandbox:/:/sbin/nologin kmem:*:5:65533::0:0:KMem Sandbox:/:/sbin/nologin games:*:7:13::0:0:Games pseudo-user:/usr/games:/sbin/nologin news:*:8:8::0:0:News Subsystem:/:/sbin/nologin man:*:9:9::0:0:Mister Man Pages:/usr/share/man:/sbin/nologin bind:*:53:53::0:0:Bind Sandbox:/:/sbin/nologin uucp:*:66:66::0:0:UUCP pseudo-user:/var/spool/uucppublic:/usr/libexec/uucp/uucico xten:*:67:67::0:0:X-10 daemon:/usr/local/xten:/sbin/nologin pop:*:68:6::0:0:Post Office Owner:/nonexistent:/sbin/nologin nobody:*:65534:65534::0:0:Unprivileged user:/nonexistent:/sbin/nologin +::::::::: -bill basie&prompt.root; Udo Erdelhoff Contributed by 使用 Netgroups netgroups 前一节介绍的方法, 在您需要为非常少的用户和/或机器进行特殊的规则配置时还算凑合。 在更大的网络上, 您 一定会 忘记禁止某些用户登录到敏感的机器上, 或者, 甚至必须单独地修改每一台机器的配置, 因而丢掉了 NIS 最重要的优越性: 集中式 管理。 NIS 开发人员为这个问题提供的解决方案, 被称作 netgroups。 它们的作用和语义, 基本上可以等同于 &unix; 文件系统上使用的组。 主要的区别是它们没有数字化的 ID, 以及可以在 netgroup 中同时包含用户和其他 netgroup。 Netgroups 被设计用来处理大的、 复杂的包含数百用户和机器的网络。 一方面, 在您不得不处理这类情形时, 这是一个很有用的东西。 而另一方面, 它的复杂性又使得通过非常简单的例子很难解释 netgroup 到底是什么。 这一节的其余部分的例子将展示这个问题。 假设您在实验室中成功地部署 NIS 引起了上司的兴趣。 您接下来的任务是将 NIS 域扩展, 以覆盖校园中的一些其他的机器。 下面两个表格中包括了新用户和新机器, 及其简要说明。 用户名 说明 alpha, beta IT 部门的普通雇员 charlie, delta IT 部门的学徒 echo, foxtrott, golf, ... 普通雇员 able, baker, ... 目前的实习生 机器名 说明 war, death, famine, pollution 最重要的服务器。 只有 IT 部门的雇员才允许登录这些机器。 pride, greed, envy, wrath, lust, sloth 不太重要的服务器, 所有 IT 部门的成员, 都可以登录这些机器。 one, two, three, four, ... 普通工作站。 只有 真正的 雇员才允许登录这些机器。 trashcan 一台不包含关键数据的旧机器。 即使是实习生, 也允许登录它。 如果您尝试通过一个一个地阻止用户来实现这些限制, 就需要在每一个系统的 passwd 文件中, 为每一个不允许登录该系统的用户添加对应的 -user 行。 如果忘记了任何一个, 就可能会造成问题。 在进行初始配置时, 正确地配置也许不是什么问题, 但随着日复一日地添加新用户, 总有一天 您会忘记为新用户添加某个行。 毕竟, Murphy 是一个乐观的人。 使用 netgroups 来处理这一状况可以带来许多好处。 不需要单独地处理每一个用户; 您可以赋予用户一个或多个 netgroups 身份, 并允许或禁止某一个 netgroup 的所有成员登录。 如果添加了新的机器, 只需要定义 netgroup 的登录限制。 如果增加了新用户, 也只需要将用户加入一个或多个 netgroup。 这些变化是相互独立的: 不再需要 对每一个用户和机器执行 ……。 如果您的 NIS 配置经过了谨慎的规划, 就只需要修改一个中央的配置文件, 就能够允许或禁止访问某台机器的权限了。 第一步是初始化 NIS 映射 netgroup。 FreeBSD 的 &man.ypinit.8; 默认情况下并不创建这个映射, 但它的 NIS 实现能够在创建这个映射之后立即对其提供支持。 要创建空映射, 简单地输入 ellington&prompt.root; vi /var/yp/netgroup 并开始增加内容。 在我们的例子中, 至少需要四个 nergruop: IT 雇员, IT 学徒, 普通雇员和实习生。 IT_EMP (,alpha,test-domain) (,beta,test-domain) IT_APP (,charlie,test-domain) (,delta,test-domain) USERS (,echo,test-domain) (,foxtrott,test-domain) \ (,golf,test-domain) INTERNS (,able,test-domain) (,baker,test-domain) IT_EMP, IT_APP 等等, 是 netgroup 的名字。 每一个括号中的组中, 都有一些用户帐号。 组中的三个字段是: 在哪些机器上能够使用这些项。 如果不指定主机名, 则项在所有机器上都有效。 如果指定了主机, 则很容易造成混淆。 属于这个 netgroup 的帐号。 帐号的 NIS 域。 您可以从其他 NIS 域中把帐号导入到您的 netgroup 中, 如果您管理多个 NIS 域的话。 每一个字段都可以包括通配符。 参见 &man.netgroup.5; 了解更多细节。 netgroups Netgroup 的名字一般来说不应超过 8 个字符, 特别是当您的 NIS 域中有机器打算运行其它操作系统的时候。 名字是区分大小写的; 使用大写字母作为 netgroup 的名字, 能够让您更容易地区分用户、 机器和 netgroup 的名字。 某些 NIS 客户程序 (FreeBSD 以外的那些) 可能无法处理含有大量项的 netgroup。 例如, 某些早期版本的 &sunos; 会在 netgroup 中包含多于 15 个 时出现问题。 要绕过这个问题, 可以创建多个 子netgroup,每一个中包含少于 15 个用户, 以及一个包含所有 子netgroup 的真正的 netgroup: BIGGRP1 (,joe1,domain) (,joe2,domain) (,joe3,domain) [...] BIGGRP2 (,joe16,domain) (,joe17,domain) [...] BIGGRP3 (,joe31,domain) (,joe32,domain) BIGGROUP BIGGRP1 BIGGRP2 BIGGRP3 如果需要超过 225 个用户, 可以继续重复上面的过程。 激活并分发新的 NIS 映射非常简单: ellington&prompt.root; cd /var/yp ellington&prompt.root; make 这个操作会生成三个 NIS 映射, 即 netgroupnetgroup.byhostnetgroup.byuser。 用 &man.ypcat.1; 可以检查这些 NIS 映射是否可用了: ellington&prompt.user; ypcat -k netgroup ellington&prompt.user; ypcat -k netgroup.byhost ellington&prompt.user; ypcat -k netgroup.byuser 第一个命令的输出, 应该与 /var/yp/netgroup 的内容相近。 第二个命令, 如果没有指定本机专有的 netgroup, 则应该没有输出。 第三个命令, 则用于显示某个用户对应的 netgroup 列表。 客户机的设置也很简单。 要配置服务器 war, 只需进入 &man.vipw.8; 并把 +::::::::: 改为 +@IT_EMP::::::::: 现在, 只有 netgroup IT_EMP 中定义的用户会被导入到 war 的口令数据库中, 因此只有这些用户能够登录。 不过, 这个限制也会作用于 shell 的 ~, 以及所有在用户名和数字用户 ID 之间实施转换的函数的功能。 换言之, cd ~user 将不会正常工作, 而 ls -l 也将显示数字的 ID 而不是用户名, 并且 find . -user joe -print 将失败, 并给出 No such user 的错误信息。 要修正这个问题, 您需要导入所有的用户项, 而 不允许他们登录服务器 这可以通过在 /etc/master.passwd 加入另一行来完成。 这行的内容是: +:::::::::/sbin/nologin, 意思是 导入所有的项, 但导入项的 shell 则替换为 /sbin/nologin。 通过在 /etc/master.passwd 中增加默认值, 可以替换掉 passwd 中的任意字段。 务必确认 +:::::::::/sbin/nologin 这一行出现在 +@IT_EMP::::::::: 之后。 否则, 所有从 NIS 导入的用户帐号将以 /sbin/nologin 作为登录 shell。 完成上面的修改之后, 在 IT 部门有了新员工时, 只需修改一个 NIS 映射就足够了。 您也可以用类似的方法, 在不太重要的服务器上, 把先前本地版本的 /etc/master.passwd 中的 +::::::::: 改为: +@IT_EMP::::::::: +@IT_APP::::::::: +:::::::::/sbin/nologin 相关的用于普通工作站的配置则应是: +@IT_EMP::::::::: +@USERS::::::::: +:::::::::/sbin/nologin 一切平安无事, 直到数周后, 有一天策略发生了变化: IT 部门也开始招收实习生了。 IT 实习生允许使用普通的终端, 以及不太重要的服务器; 而 IT 学徒, 则可以登录主服务器。 您增加了新的 netgroup IT_INTERN, 以及新的 IT 实习生到这个 netgroup 并开始修改每一台机器上的配置…… 老话说得好:牵一发, 动全身 NIS 通过 netgroup 来建立 netgroup 的能力, 正可以避免这样的情形。 一种可能的方法是建立基于角色的 netgroup。 例如, 您可以创建称为 BIGSRV 的 netgroup, 用于定义最重要的服务器上的登录限制, 以及另一个成为 SMALLSRV 的 netgroup, 用以定义次重要的服务器, 以及第三个, 用于普通工作站的 netgroup USERBOX。 这三个 netgroup 中的每一个, 都包含了允许登录到这些机器上的所有 netgroup。 您的 NIS 映射中的新项如下所示: BIGSRV IT_EMP IT_APP SMALLSRV IT_EMP IT_APP ITINTERN USERBOX IT_EMP ITINTERN USERS 这种定义登录限制的方法, 在您能够将机器分组并加以限制的时候可以工作的相当好。 不幸的是, 这是种例外, 而非常规情况。 多数时候, 需要按机器去定义登录限制。 与机器相关的 netgroup 定义, 是处理上述策略改动的另一种可能的方法。 此时, 每台机器的 /etc/master.passwd 中, 都包含两个 + 开头的行。 第一个用于添加允许登录的 netgroup 帐号, 而第二个则用于增加其它帐号, 并把 shell 设置为 /sbin/nologin。 使用 全大写 的机器名作为 netgroup 名是个好主意。 换言之, 这些行应该类似于: +@BOXNAME::::::::: +:::::::::/sbin/nologin 一旦在所有机器上都完成了这样的修改, 就再也不需要修改本地的 /etc/master.passwd 了。 所有未来的修改都可以在 NIS 映射中进行。 这里是一个例子, 其中展示了在这一应用情景中所需要的 netgroup 映射, 以及其它一些常用的技巧: # Define groups of users first IT_EMP (,alpha,test-domain) (,beta,test-domain) IT_APP (,charlie,test-domain) (,delta,test-domain) DEPT1 (,echo,test-domain) (,foxtrott,test-domain) DEPT2 (,golf,test-domain) (,hotel,test-domain) DEPT3 (,india,test-domain) (,juliet,test-domain) ITINTERN (,kilo,test-domain) (,lima,test-domain) D_INTERNS (,able,test-domain) (,baker,test-domain) # # Now, define some groups based on roles USERS DEPT1 DEPT2 DEPT3 BIGSRV IT_EMP IT_APP SMALLSRV IT_EMP IT_APP ITINTERN USERBOX IT_EMP ITINTERN USERS # # And a groups for a special tasks # Allow echo and golf to access our anti-virus-machine SECURITY IT_EMP (,echo,test-domain) (,golf,test-domain) # # machine-based netgroups # Our main servers WAR BIGSRV FAMINE BIGSRV # User india needs access to this server POLLUTION BIGSRV (,india,test-domain) # # This one is really important and needs more access restrictions DEATH IT_EMP # # The anti-virus-machine mentioned above ONE SECURITY # # Restrict a machine to a single user TWO (,hotel,test-domain) # [...more groups to follow] 如果您正使用某种数据库来管理帐号, 应该可以使用您的数据库的报告工具来创建映射的第一部分。 这样, 新用户就自动地可以访问这些机器了。 最后的提醒: 使用基于机器的 netgroup 并不总是适用的。 如果正在为学生实验室部署数十台甚至上百台同样的机器, 您应该使用基于角色的 netgroup, 而不是基于机器的 netgroup, 以便把 NIS 映射的尺寸保持在一个合理的范围内。 需要牢记的事项 这里是一些其它在使用 NIS 环境时需要注意的地方。 每次需要在实验室中增加新用户时, 必须 在 NIS 服务器上加入用户, 而且 一定要记得重建 NIS 映射。 如果您忘记了这样做, 新用户将无法登录除 NIS 主服务器之外的任何其它机器。 例如, 如果要在实验室增加新用户 jsmith, 我们需要: &prompt.root; pw useradd jsmith &prompt.root; cd /var/yp &prompt.root; make test-domain 也可以运行 adduser jsmith 而不是 pw useradd jsmith. 将管理用的帐号排除在 NIS 映射之外。 一般来说, 您不希望这些管理帐号和口令被扩散到那些包含不应使用它们的用户的机器上。 确保 NIS 主和从服务器的安全, 并尽可能减少其停机时间。 如果有人攻入或简单地关闭这些机器, 则整个实验室的任也就无法登录了。 这是集中式管理系统中最薄弱的环节。 如果没有保护好 NIS 服务器, 您就有大批愤怒的用户需要对付了! NIS v1 兼容性 FreeBSD 的 ypserv 提供了某些为 NIS v1 客户提供服务的支持能力。 FreeBSD 的 NIS 实现, 只使用 NIS v2 协议, 但其它实现可能会包含 v1 协议, 以提供对旧系统的向下兼容能力。 随这些系统提供的 ypbind 服务将首先尝试绑定 NIS v1 服务器, 即使它们并不真的需要它 (有些甚至可能会一直广播搜索请求, 即使已经从某台 v2 服务器得到了回应也是如此)。 注意, 尽管支持一般的客户机调用, 这个版本的 ypserv 并不能处理 v1 的映射传送请求; 因而, 它就不能与较早的支持 v1 协议的 NIS 服务器配合使用, 无论是作为主服务器还是从服务器。 幸运的是, 现今应该已经没有仍然在用的这样的服务器了。 同时作为 NIS 客户机的 NIS 服务器 在多服务器域的环境中, 如果服务器同时作为 NIS 客户, 在运行 ypserv 时要特别小心。 一般来说, 强制服务器绑定自己要比允许它们广播绑定请求要好, 因为这种情况下它们可能会相互绑定。 某些怪异的故障, 很可能是由于某一台服务器停机, 而其它服务器都依赖其服务所导致的。 最终, 所有的客户机都会超时并绑定到其它服务器, 但这个延迟可能会相当可观, 而且恢复之后仍然存在再次发生此类问题的隐患。 您可以强制一台机器绑定到特定的服务器, 这是通过 ypbind 参数来完成的。 如果不希望每次启动 NIS 服务器时都手工完成这项工作, 可以在 /etc/rc.conf 中加入: nis_client_enable="YES" # run client stuff as well nis_client_flags="-S NIS domain,server" 参见 &man.ypbind.8; 以了解更多情况。 口令格式 NIS 口令格式 在实现 NIS 时, 口令格式的兼容性问题是一种最为常见的问题。 假如您的 NIS 服务器使用 DES 加密口令, 则它只能支持使用 DES 的客户机。 例如, 如果您的网络上有 &solaris; NIS 客户机, 则几乎肯定需要使用 DES 加密口令。 要检查您的服务器和客户机使用的口令格式, 需要查看 /etc/login.conf。 如果主机被配置为使用 DES 加密的口令, 则 default class 将包含类似这样的项: default:\ :passwd_format=des:\ :copyright=/etc/COPYRIGHT:\ [Further entries elided] 其他一些可能的 passwd_format 包括 blfmd5 (分别对应于 Blowfish 和 MD5 加密口令)。 如果修改了 /etc/login.conf, 就必须重建登录性能数据库, 这是通过以 root 身份运行下面的程序来完成的: &prompt.root; cap_mkdb /etc/login.conf 已经在 /etc/master.passwd 中的口令的格式不会被更新, 直到用户在登录性能数据库重建 之后 首次修改口令为止。 接下来, 为了确保所有的口令都按照您选择的格式加密了, 还需要检查 /etc/auth.confcrypt_default 给出的优先选择的口令格式。 要完成此工作, 将您选择的格式放到列表的第一项。 例如, 当使用 DES 加密的口令时, 对应项应为: crypt_default = des blf md5 在每一台基于 &os; 的 NIS 服务器和客户机上完成上述工作之后, 就可以肯定您的网络上它们都在使用同样的口令格式了。 如果在 NIS 客户机上做身份验证时发生问题, 这也是第一个可能出现问题的地方。 注意: 如果您希望在混合的网络上部署 NIS 服务器, 可能就需要在所有系统上都使用 DES, 因为这是所有系统都能够支持的最低限度的公共标准。 Greg Sutter Written by 网络自动配置 (DHCP) 什么是 DHCP? 动态主机配置协议 DHCP Internet Software Consortium (ISC) DHCP, 动态主机配置协议, 是一种让系统得以连接到网络上, 并获取所需要的配置参数手段。 FreeBSD 6.0 之前的版本, 采用的是 ISC (Internet Software Consortium) 的 DHCP 客户端 (&man.dhclient.8;) 实现。 更高版本使用的则是来自 OpenBSD 3.7 的 OpenBSD dhclient。 这里提供的所有关于 dhclient 的信息, 都是以 ISC 或 OpenBSD DHCP 客户端程序为准的。 DHCP 服务器是 ISC 软件包的一部分。 这一节都介绍哪些内容 这一节描述了 ISC 和 DHCP 系统中的客户端, 以及和 ISC DHCP 系统中的服务器端的组件。 客户端程序, dhclient, 是随 FreeBSD 作为它的一部分提供的; 而服务器部分, 则可以通过 net/isc-dhcp3-server port 得到。 &man.dhclient.8;、 &man.dhcp-options.5;、 以及 &man.dhclient.conf.5; 联机手册, 加上下面所介绍的参考文献, 都是非常有用的资源。 它如何工作 UDP 当 DHCP 客户程序, dhclient 在客户机上运行时, 它会开始广播请求配置信息的消息。 默认情况下, 这些请求是在 UDP 端口 68 上。 服务器通过 UDP 67 给出响应, 向客户机提供一个 IP 地址, 以及其他有关的配置参数, 例如子网掩码、 路由器, 以及 DNS 服务器。 所有这些信息都会以 DHCP lease 的形式给出, 并且只在一段特定的时间内有效 (这是由 DHCP 服务器的维护者配置的)。 这样, 那些已经断开网络的客户机使用的陈旧的 IP 地址就能被自动地回收了。 DHCP 客户程序可以从服务器端获取大量的信息。 关于能获得的信息的详细列表, 请参考 &man.dhcp-options.5;。 FreeBSD 集成 FreeBSD 完全地集成了 ISC 或 OpenBSD 的 DHCP 客户端, dhclient (取决于您运行的 &os; 版本)。 DHCP 客户端被安装程序直接支持, 并且是基本系统的一部分。 这使得您不再需要去了解那些已经运行了 DHCP 服务器的网络的具体配置参数。 从 FreeBSD 3.2 开始, 每一个发行版中均包含 dhclient sysinstall sysinstall 能够支持 DHCP。 在 sysinstall 中配置网络接口时, 它询问的第二个问题便是: Do you want to try DHCP configuration of the interface? (您是否希望在此接口上尝试 DHCP 配置?)。 如果做肯定的回答, 则将运行 dhclient, 一旦成功, 则将自动地填写网络配置信息。 要在系统启动时使用 DHCP, 您必须做两件事: DHCP 需求 您的内核中, 必须包含 bpf 设备。 如果需要这样做, 需要将 device bpf 添加到内核的编译配置文件中, 并重新编译内核。 要了解关于编译内核的进一步信息, 请参见 bpf 设备已经是 FreeBSD 发行版中默认的 GENERIC 内核的一部分了, 因此如果您没有对内核进行定制, 则不用创建一份新的内核配置文件, DHCP 就能工作了。 对于那些安全意识很强的人来说, 您应该知道 bpf 也是包侦听工具能够正确工作的条件之一 (当然, 它们还需要以 root 身份运行才行)。 bpf 使用 DHCP 所必须的, 但如果您对安全非常敏感, 则很可能会有理由不把 bpf 加入到您的内核配置中, 直到您真的需要使用 DHCP 为止。 编辑您的 /etc/rc.conf 并加入下面的设置: ifconfig_fxp0="DHCP" 务必将 fxp0 替换为您希望自动配置的网络接口的名字, 您可以在 找到更进一步的介绍。 如果您希望使用另一位置的 dhclient, 或者需要给 dhclient 传递其他参数, 还可以添加下面的配置 (根据需要进行修改): dhclient_program="/sbin/dhclient" dhclient_flags="" DHCP 服务器 DHCP 服务器, dhcpd, 是作为 net/isc-dhcp3-server port 的一部分提供的。 这个 port 包括了 ISC DHCP 服务器及其文档。 文件 DHCP 配置文件 /etc/dhclient.conf dhclient 需要一个配置文件, /etc/dhclient.conf。 一般说来, 这个文件中只包括注释, 而默认值基本上都是合理的。 这个配置文件在 &man.dhclient.conf.5; 联机手册中进行了进一步的阐述。 /sbin/dhclient dhclient 是一个静态连编的, 它被安装到 /sbin 中。 &man.dhclient.8; 联机手册给出了关于 dhclient 的进一步细节。 /sbin/dhclient-script dhclient-script 是一个 FreeBSD 专用的 DHCP 客户端配置脚本。 在 &man.dhclient-script.8; 中对它进行了描述, 但一般来说, 用户不需要对其进行任何修改, 就能够让一切正常运转了。 /var/db/dhclient.leases DHCP 客户程序会维护一个数据库来保存有效的 lease, 它们被以日志的形式保存到这个文件中。 &man.dhclient.leases.5; 给出了更为细致的介绍。 进阶读物 DHCP 协议的完整描述是 RFC 2131。 关于它的其他信息资源的站点 也提供了详尽的资料。 安装和配置 DHCP 服务器 这一章包含哪些内容 这一章提供了关于如何在 FreeBSD 系统上使用 ISC (Internet 软件协会) 的 DHCP 实现套件来架设 DHCP 服务器的信息。 DHCP 套件中的服务器部分并没有作为 FreeBSD 的一部分来提供, 因此您需要安装 net/isc-dhcp3-server port 才能提供这个服务。 请参见 以了解关于如何使用 Ports Collection 的进一步详情。 安装 DHCP 服务器 DHCP 安装 为了在您的 FreeBSD 系统上进行配置以便作为 DHCP 服务器来使用, 需要把 &man.bpf.4; 设备编译进内核。 要完成这项工作, 需要将 device bpf 加入到您的内核配置文件中, 并重新联编内核。 要得到关于如何联编内核的进一步信息, 请参见 bpf 设备是 FreeBSD 所附带的 GENERIC 内核中已经联入的组件, 因此您并不需要为了让 DHCP 正常工作而特别地定制内核。 如果您有较强的安全意识, 应该注意 bpf 同时也是让听包程序能够正确工作的设备 (尽管这类程序仍然需要以特权用户身份运行)。 bpf 使用 DHCP 所必需的, 但如果您对安全非常敏感, 您可能会不希望将 bpf 放进内核, 直到您真的认为 DHCP 是必需的为止。 接下来要做的是编辑示范的 dhcpd.conf, 它由 net/isc-dhcp3-server port 安装。 默认情况下, 它的名字应该是 /usr/local/etc/dhcpd.conf.sample, 在开始修改之前, 您需要把它复制为 /usr/local/etc/dhcpd.conf 配置 DHCP 服务器 DHCP dhcpd.conf dhcpd.conf 包含了一系列关于子网和主机的定义, 下面的例子可以帮助您理解它: option domain-name "example.com"; option domain-name-servers 192.168.4.100; option subnet-mask 255.255.255.0; default-lease-time 3600; max-lease-time 86400; ddns-update-style none; subnet 192.168.4.0 netmask 255.255.255.0 { range 192.168.4.129 192.168.4.254; option routers 192.168.4.1; } host mailhost { hardware ethernet 02:03:04:05:06:07; fixed-address mailhost.example.com; } 这个选项指定了提供给客户机作为默认搜索域的域名。 请参考 &man.resolv.conf.5; 以了解关于这一概念的详情。 这个选项用于指定一组客户机使用的 DNS 服务器, 它们之间以逗号分隔。 提供给客户机的子网掩码。 客户机可以请求租约的有效期, 而如果没有, 则服务器将指定一个租约有效期, 也就是这个值 (单位是秒)。 这是服务器允许租出地址的最大时长。 如果客户机请求了更长的租期, 则它将得到一个地址, 但其租期仅限于 max-lease-time 秒。 这个选项用于指定 DHCP 服务器在一个地址被接受或释放时是否应对应尝试更新 DNS。 在 ISC 实现中, 这一选项是 必须指定的 指定地址池中可以用来分配给客户机的 IP 地址范围。 在这个范围之间, 以及其边界的 IP 地址将分配给客户机。 定义客户机的默认网关。 主机的硬件 MAC 地址 (这样 DHCP 服务器就能够在接到请求时知道请求的主机身份)。 指定总是得到同一 IP 地址的主机。 请注意在此处使用主机名是对的, 因为 DHCP 服务器会在返回租借地址信息之前自行解析主机名。 在配制好 dhcpd.conf 之后, 应在 /etc/rc.conf 中启用 DHCP 服务器, 也就是增加: dhcpd_enable="YES" dhcpd_ifaces="dc0" 此处的 dc0 接口名应改为 DHCP 服务器需要监听 DHCP 客户端请求的接口 (如果有多个, 则用空格分开)。 接下来, 可以用下面的命令来启动服务: &prompt.root; /usr/local/etc/rc.d/isc-dhcpd.sh start 如果未来您需要修改服务器的配置, 请务必牢记发送 SIGHUP 信号给 dhcpd不会 导致配置文件的重新加载, 而这在其他服务程序中则是比较普遍的约定。 您需要发送 SIGTERM 信号来停止进程, 然后使用上面的命令来重新启动它。 文件 DHCP 配置文件 /usr/local/sbin/dhcpd dhcpd 是静态连接的, 并安装到 /usr/local/sbin 中。 随 port 安装的 &man.dhcpd.8; 联机手册提供了关于 dhcpd 更为详尽的信息。 /usr/local/etc/dhcpd.conf dhcpd 需要配置文件, 即 /usr/local/etc/dhcpd.conf 才能够向客户机提供服务。 这个文件需要包括应提供给客户机的所有信息, 以及关于服务器运行的其他信息。 此配置文件的详细描述可以在随 port 安装的 &man.dhcpd.conf.5; 联机手册上找到。 /var/db/dhcpd.leases DHCP 服务器会维护一个它签发的租用地址数据库, 并保存在这个文件中, 这个文件是以日志的形式保存的。 随 port 安装的 &man.dhcpd.leases.5; 联机手册提供了更详细的描述。 /usr/local/sbin/dhcrelay dhcrelay 在更为复杂的环境中, 可以用来支持使用 DHCP 服务器转发请求给另一个独立网络上的 DHCP 服务器。 如果您需要这个功能, 需要安装 net/isc-dhcp3-relay port。 &man.dhcrelay.8; 联机手册提供了更为详尽的介绍。 Chern Lee Contributed by Tom Rhodes Daniel Gerzo 域名系统 (<acronym>DNS</acronym>) 纵览 BIND &os; 在默认情况下使用一个版本的 BIND (Berkeley Internet Name Domain), 这是目前最为流行的 DNS 协议实现。 DNS 是一种协议, 可以通过它将域名同 IP 地址相互对应。 例如, 查询 www.FreeBSD.org 将得到 &os; Project 的 web 服务器的 IP 地址, 而查询 ftp.FreeBSD.org 则将得到响应的 FTP 机器的 IP 地址。 类似地, 也可以做相反的事情。 查询 IP 地址可以得到其主机名。 当然, 完成 DNS 查询并不需要在系统中运行域名服务器。 目前, 默认情况下&os; 使用的是 BIND9 DNS 服务软件。 我们内建于系统中的版本提供了增强的安全特性、 新的文件目录结构, 以及自动的 &man.chroot.8; 配置。 DNS 在 Internet 上的 DNS 是通过一套较为复杂的权威根域名系统, 顶级域名 (TLD), 以及一系列小规模的, 提供少量域名解析服务并对域名信息进行缓存的域名服务器组成的。 目前, BIND 由 Internet Software Consortium 维护。 术语 要理解这份文档, 需要首先了解一些相关的 DNS 术语。 resolver (解析器) reverse DNS (反向 DNS) root zone (根域) 术语 定义 正向 DNS 将域名映射到 IP 地址 原点 (Origin) 表示特定域文件所在的域 named, BIND, 域名服务器 在 &os; 中 BIND 域名服务器软件包的常见叫法。 解析器 (Resolver) 计算机用以向域名服务器查询域名信息的一个系统进程 反向 DNS 与正向 DNS 相对; 将 IP 地址映射为主机名 根域 Internet 域层次的起点。 所有的域都在根域之下, 类似文件系统中, 文件都在根目录之下那样。 域 (Zone) 独立的域, 子域, 或者由同一机构管理的 DNS 的一部分。 例子 域的例子: . 是根域。 org. 是根域之下的一个顶级域名 (TLD)。 example.org. 是在 org. TLD 之下的一个域。 1.168.192.in-addr.arpa 是一个表示所有 192.168.1.* IP 地址空间中 IP 地址的域。 如您所见, 域名中越细节的部分会越靠左出现。 例如, example.org. 就比 org. 范围更小, 类似地 org. 又比根域更小。 域名各个部分的格局与文件系统十分类似: /dev 目录在根目录之下, 等等。 运行域名服务器的理由 域名服务器通常会有两种形式: 权威域名服务器, 以及缓存域名服务器。 下列情况需要有权威域名服务器: 想要向全世界提供 DNS 信息, 并对请求给出权威应答。 注册了类似 example.org 的域, 而需要将 IP 指定到其下的主机名上。 某个 IP 地址块需要反向 DNS 项 (IP 到主机名)。 备份服务器, 或常说的从 (slave) 服务器, 会在主服务器出现问题或无法访问时来应答查询请求。 下列情况需要有缓存域名服务器: 本地的 DNS 服务器能够缓存, 并比直接向外界的域名服务器请求更快地得到应答。 当有人查询 www.FreeBSD.org 时,解析器通常会向上级 ISP 的域名服务器发出请求, 并获得回应。 如果有本地的缓存 DNS 服务器, 查询只有在第一次被缓存 DNS 服务器发到外部世界。 其他的查询不会发向局域网外, 因为它们已经有在本地的缓存了。 DNS 如何运作 在 &os; 中, BIND 服务程序被称为 named, 其原因显而易见。 文件 描述 &man.named.8; BIND 服务程序 &man.rndc.8; 域名服务控制程序 /etc/namedb BIND 存放域名信息的位置。 /etc/namedb/named.conf 域名服务配置文件 随在服务器上配置的域的性质不同, 域的定义文件一般会存放到 /etc/namedb 目录中的 masterslave, 或 dynamic 子目录中。 这些文件中提供了域名服务器在响应查询时所需要的 DNS 信息。 启动 BIND BIND starting (启动) 由于 BIND 是默认安装的, 因此配置它相对而言很简单。 默认的 named 配置是在 &man.chroot.8; 环境中提供基本的域名解析服务。 如果希望启动一下这种配置, 可以执行下面的命令: &prompt.root; /etc/rc.d/named forcestart 如果希望 named 服务在每次启动的时候都能够启动, 需要在 /etc/rc.conf 中加入: named_enable="YES" 当然, 除了这份文档所介绍的配置选项之外, 在 /etc/namedb/named.conf 中还有很多其它的选项。 不过, 如果您需要了解 &os; 中用于启动 named 的那些选项的话, 则可以查看 /etc/defaults/rc.conf 中的 named_* 参数, 并参考 &man.rc.conf.5; 联机手册。 除此之外, 也是一个不错的起点。 配置文件 BIND configuration files (配置文件) 目前, named 的配置文件存放于 /etc/namedb 目录, 在使用前应根据需要进行修改, 除非您只打算让它完成简单的域名解析服务。 这个目录同时也是您进行绝大多数配置的地方。 使用 <command>make-localhost</command> 要为 localhost 配置权威域, 需要进入 /etc/namedb 目录, 并运行下面的命令: &prompt.root; sh make-localhost 如果一切正常的话, 在 master 子目录中会增加一组文件。 本地域名对应的文件是 localhost.rev, 而 IPv6 对应的配置则是 localhost-v6.rev。 作为默认配置, 所需的信息已经放到了 named.conf 文件中。 <filename>/etc/namedb/named.conf</filename> // $FreeBSD$ // // Refer to the named.conf(5) and named(8) man pages, and the documentation // in /usr/share/doc/bind9 for more details. // // If you are going to set up an authoritative server, make sure you // understand the hairy details of how DNS works. Even with // simple mistakes, you can break connectivity for affected parties, // or cause huge amounts of useless Internet traffic. options { directory "/etc/namedb"; pid-file "/var/run/named/pid"; dump-file "/var/dump/named_dump.db"; statistics-file "/var/stats/named.stats"; // If named is being used only as a local resolver, this is a safe default. // For named to be accessible to the network, comment this option, specify // the proper IP address, or delete this option. listen-on { 127.0.0.1; }; // If you have IPv6 enabled on this system, uncomment this option for // use as a local resolver. To give access to the network, specify // an IPv6 address, or the keyword "any". // listen-on-v6 { ::1; }; // In addition to the "forwarders" clause, you can force your name // server to never initiate queries of its own, but always ask its // forwarders only, by enabling the following line: // // forward only; // If you've got a DNS server around at your upstream provider, enter // its IP address here, and enable the line below. This will make you // benefit from its cache, thus reduce overall DNS traffic in the Internet. /* forwarders { 127.0.0.1; }; */ 正如注释所言, 如果希望从上级缓存中受益, 可以在此处启用 forwarders。 正常情况下, 域名服务器会逐级地查询 Internet 来找到特定的域名服务器, 直到得到答案为止。 这个选项将让它首先查询上级域名服务器 (或另外提供的域名服务器), 从而从它们的缓存中得到结果。 如果上级域名服务器是一个繁忙的高速域名服务器, 则启用它将有助于改善服务品质。 127.0.0.1 不会 正常工作。 一定要把地址改为您上级服务器的 IP 地址。 /* * If there is a firewall between you and nameservers you want * to talk to, you might need to uncomment the query-source * directive below. Previous versions of BIND always asked * questions using port 53, but BIND versions 8 and later * use a pseudo-random unprivileged UDP port by default. */ // query-source address * port 53; }; // If you enable a local name server, don't forget to enter 127.0.0.1 // first in your /etc/resolv.conf so this server will be queried. // Also, make sure to enable it in /etc/rc.conf. zone "." { type hint; file "named.root"; }; zone "0.0.127.IN-ADDR.ARPA" { type master; file "master/localhost.rev"; }; // RFC 3152 zone "1.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.IP6.ARPA" { type master; file "master/localhost-v6.rev"; }; // NB: Do not use the IP addresses below, they are faked, and only // serve demonstration/documentation purposes! // // Example slave zone config entries. It can be convenient to become // a slave at least for the zone your own domain is in. Ask // your network administrator for the IP address of the responsible // primary. // // Never forget to include the reverse lookup (IN-ADDR.ARPA) zone! // (This is named after the first bytes of the IP address, in reverse // order, with ".IN-ADDR.ARPA" appended.) // // Before starting to set up a primary zone, make sure you fully // understand how DNS and BIND works. There are sometimes // non-obvious pitfalls. Setting up a slave zone is simpler. // // NB: Don't blindly enable the examples below. :-) Use actual names // and addresses instead. /* An example master zone zone "example.net" { type master; file "master/example.net"; }; */ /* An example dynamic zone key "exampleorgkey" { algorithm hmac-md5; secret "sf87HJqjkqh8ac87a02lla=="; }; zone "example.org" { type master; allow-update { key "exampleorgkey"; }; file "dynamic/example.org"; }; */ /* Examples of forward and reverse slave zones zone "example.com" { type slave; file "slave/example.com"; masters { 192.168.1.1; }; }; zone "1.168.192.in-addr.arpa" { type slave; file "slave/1.168.192.in-addr.arpa"; masters { 192.168.1.1; }; }; */ named.conf 中, 还给出了从域、转发域和反解析域的例子。 如果新增了域, 就必需在 named.conf 中加入对应的项目。 例如, 用于 example.org 的域文件的描述类似下面这样: zone "example.org" { type master; file "master/example.org"; }; 语句所标示的那样, 这是一个主域, 其信息保存在 /etc/namedb/master/example.org 中, 如 语句所示。 zone "example.org" { type slave; file "slave/example.org"; }; 在从域的情形中, 所指定的域的信息会从主域名服务器传递过来, 并保存到对应的文件中。 当主域服务器发生问题或不可达时, 从域名服务器就有一份可用的域名信息, 从而能够对外提供服务。 域文件 BIND zone files (域文件) 下面的例子展示了用于 example.org 的主域文件 (存放于 /etc/namedb/master/example.org): $TTL 3600 ; 1 hour example.org. IN SOA ns1.example.org. admin.example.org. ( 2006051501 ; Serial 10800 ; Refresh 3600 ; Retry 604800 ; Expire 86400 ; Minimum TTL ) ; DNS Servers IN NS ns1.example.org. IN NS ns2.example.org. ; MX Records IN MX 10 mx.example.org. IN MX 20 mail.example.org. IN A 192.168.1.1 ; Machine Names localhost IN A 127.0.0.1 ns1 IN A 192.168.1.2 ns2 IN A 192.168.1.3 mx IN A 192.168.1.4 mail IN A 192.168.1.5 ; Aliases www IN CNAME @ 请注意以 . 结尾的主机名是全称主机名, 而结尾没有 . 的则是相对于原点的主机名。 例如, www 将被转换为 www.原点. 在这个假想的域信息文件中, 我们的原点是 example.org., 因此 www 将被当作 www.example.org. 域信息文件的格式如下: 记录名 IN 记录类型 值 DNS 记录 最常用的 DNS 记录: SOA 域权威开始 NS 权威域名服务器 A 主机地址 CNAME 别名对应的正规名称 MX 邮件传递服务器 PTR 域名指针 (用于反向 DNS) example.org. IN SOA ns1.example.org. admin.example.org. ( 2006051501 ; Serial 10800 ; Refresh after 3 hours 3600 ; Retry after 1 hour 604800 ; Expire after 1 week 86400 ) ; Minimum TTL of 1 day example.org. 域名, 同时也是这个域信息文件的原点。 ns1.example.org. 该域的主/权威域名服务器。 admin.example.org. 此域的负责人的电子邮件地址, 其中 @ 被换掉了。 (admin@example.org 对应 admin.example.org) 2006051501 文件的序号。 每次修改域文件时都必须增加这个数字。 现今, 许多管理员会考虑使用 yyyymmddrr 这样的格式来表示序号。 2006051501 通常表示上次修改于 05/15/2006, 而后面的 01 则表示在那天的第一次修改。 序号非常重要, 它用于通知从域服务器更新数据。 IN NS ns1.example.org. 这是一个 NS 项。 每个准备提供权威应答的服务器都必须有一个对应项。 localhost IN A 127.0.0.1 ns1 IN A 192.168.1.2 ns2 IN A 192.168.1.3 mx IN A 192.168.1.4 mail IN A 192.168.1.5 A 记录指明了机器名。 正如在前面所按倒的, ns1.example.org 将解析为 192.168.1.2 IN A 192.168.1.1 这一行把当前原点 example.org 指定为使用 IP 地址 192.168.1.1 www IN CNAME @ 正规名 (CNAME) 记录通常用于为某台机器指定别名。 在这个例子中, 将 www 指定成了 机器的一个别名, 后者的名字与域名 example.org 相同 (192.168.1.1)。 CNAME 也可以用来提供主机别名, 或将一个主机名以轮转 (round robin) 方式指定到多台服务器。 MX 记录 IN MX 10 mail.example.org. MX 记录表示哪个邮件服务器负责接收发到这个域的邮件。 mail.example.org 是邮件服务器的主机名, 而 10 则是它的优先级。 可以有多台邮件服务器, 其优先级分别是 10、 20 等等。 尝试向 example.org 投递邮件的服务器, 会首先尝试优先级最高的 MX (优先级数值最低的记录)、 接着尝试次高的, 并重复这一过程直到邮件递送到达为止。 对于 in-addr.arpa 域名信息文件 (反向 DNS), 使用了同样的格式, 只是 PTR 项代替了 A 或 CNAME 的位置。 $TTL 3600 1.168.192.in-addr.arpa. IN SOA ns1.example.org. admin.example.org. ( 2006051501 ; Serial 10800 ; Refresh 3600 ; Retry 604800 ; Expire 3600 ) ; Minimum IN NS ns1.example.org. IN NS ns2.example.org. 1 IN PTR example.org. 2 IN PTR ns1.example.org. 3 IN PTR ns2.example.org. 4 IN PTR mx.example.org. 5 IN PTR mail.example.org. 这个文件给出了上述假想域中 IP 地址到域名的映射关系。 缓存域名服务器 BIND 缓存域名服务器 缓存域名服务器是对任何域都不提供权威解析的域名服务器。 它自己简单地完成查询, 并记住这些查询以备后续使用。 要建立这样的服务器, 只需像平时一样配置一个域名服务器, 而不配置域就可以了。 安全 尽管 BIND 是最为常用的 DNS 实现, 但它总是有一些安全问题。 时常会有人发现一些可能的甚至可以利用的安全漏洞。 尽管 &os; 会自动将 named 放到 &man.chroot.8; 环境中运行, 但仍有一些其它可用的安全机制来帮助您规避潜在的针对 DNS 服务的攻击。 阅读 CERT 的安全公告, 并订阅 the &a.security-notifications; 是一个有助于帮助您了解最新 Internet 及 &os; 安全问题的好习惯。 如果发现了问题, 确保源代码是最新的, 并重新联编一份 named 不会给您带来任何麻烦。 进一步阅读 BIND/named 联机手册: &man.rndc.8; &man.named.8; &man.named.conf.5; 官方的 ISC BIND 页面 Official ISC BIND Forum BIND9 FAQ O'Reilly DNS 和 BIND 第 5 版 RFC1034 - 域名 - 概念和工具 RFC1035 - 域名 - 实现及其标准 Murray Stokely Contributed by Apache HTTP 服务器 web 服务器 配置 Apache 纵览 &os; 被用于运行许多全球最为繁忙的 web 站点。 大多数 Internet 上的 web 服务器, 都使用 Apache HTTP 服务器Apache 软件包可以在您的 FreeBSD 安装盘上找到。 如果没有在首次安装时附带安装 Apache, 则可以通过 www/apache13www/apache22 port 来安装。 一旦成功地安装了 Apache, 就必须对其进行配置。 这一节介绍了 1.3.X 版本的 Apache HTTP 服务器 的配置, 因为它是随 &os; 一同使用的最多的版本。 Apache 2.X 引入了很多新技术, 但在此并不讨论。 要了解关于 Apache 2.X 的更多资料, 请参见 配置 Apache 配置文件 主要的 Apache HTTP Server 配置文件, 在 &os; 上会安装为 /usr/local/etc/apache/httpd.conf。 这是一个典型的 &unix; 文本配置文件, 它使用 # 作为注释符。 关于全部配置选项的详尽介绍超出了本书的范围, 这里将只介绍最常被修改的那些。 ServerRoot "/usr/local" 这指定了 Apache 安装的顶级目录。 执行文件被放到服务器根目录 (server root) 的 binsbin 子目录中, 而配置文件则位于 etc/apache ServerAdmin you@your.address 这个地址是在服务器发生问题时应发送电子邮件的地址, 它会出现在服务器生成的页面上, 例如错误页面。 ServerName www.example.com ServerName 允许您配置发送回客户端的主机名, 如果您的服务器被用户以别的名字访问 (例如, 使用 www 而不是主机本身的真实名字)。 DocumentRoot "/usr/local/www/data" DocumentRoot: 这个目录是您的文档所在的目录。 默认情况下, 所有的请求都会从这个位置去获取, 但也可以通过符号连接和别名指定其它的位置。 在修改配置之前备份 Apache 的配置文件永远是一个好习惯。 一旦对初始配置满意了, 就可以开始运行 Apache 了。 运行 <application>Apache</application> Apache 启动和停止 与许多其它网络服务不同, Apache 并不依赖 inetd 超级服务器来运行。 一般情况下会把它配置为一个独立的服务器, 以期在客户的 web 浏览器连入 HTTP 请求时, 能够获得更好的性能。 它提供了一个 shell 脚本来使启动、 停止和重新启动服务器变得尽可能地简单。 首次启动 Apache, 只需执行: &prompt.root; /usr/local/sbin/apachectl start 可以在任何时候使用下面的命令来停止服务: &prompt.root; /usr/local/sbin/apachectl stop 当由于某种原因修改了配置文件之后, 需要重启服务器: &prompt.root; /usr/local/sbin/apachectl restart 要在重启 Apache 服务器时不中断当前的连接, 则应运行: &prompt.root; /usr/local/sbin/apachectl graceful 更多的信息, 可以在 &man.apachectl.8; 联机手册中找到。 要在系统启动时启动 Apache, 则应在 /etc/rc.conf 中加入: apache_enable="YES" 或者对于Apache 2.2: apache22_enable="YES" 如果您希望在系统引导时启动 Apache httpd 程序并指定其它一些选项, 则可以把下面的行加到 rc.conf apache_flags="" 现在 web 服务器就开始运行了, 您可以使用 web 浏览器打开 http://localhost/。 默认显示的 web 页面是 /usr/local/www/data/index.html 虚拟主机 Apache 支持两种不同类型的虚拟主机。 第一种方法是基于名字的虚拟主机。 基于名字的虚拟主机使用客户机发来的 HTTP/1.1 头来辨别主机名。 这使得不同的域得以共享同一个 IP 地址。 要配置 Apache 来使用基于名字的虚拟主机, 需要把类似下面的项加到您的 httpd.conf 中: NameVirtualHost * 如果您的 web 服务器的名字是 www.domain.tld, 而您希望建立一个 www.someotherdomain.tld 的虚拟域, 则应在 httpd.conf 中加入: <VirtualHost *> ServerName www.domain.tld DocumentRoot /www/domain.tld </VirtualHost> <VirtualHost *> ServerName www.someotherdomain.tld DocumentRoot /www/someotherdomain.tld </VirtualHost> 您需要把上面的地址和文档路径改为所使用的那些。 要了解关于虚拟主机的更多信息, 请参考官方的 Apache 文档, 这些文档可以在 找到。 Apache 模块 Apache 模块 有许多不同的 Apache 模块, 它们可以在基本的服务器基础上提供许多附加的功能。 FreeBSD 的 Ports Collection 为安装 Apache 和常用的附加模块提供了非常方便的方法。 mod_ssl web 服务器 安全 SSL 密码学 mod_ssl 这个模块使用 OpenSSL 库, 来提供通过 安全套接字层 (SSL v2/v3) 和 传输层安全 (TLS v1) 协议的强加密能力。 这个模块提供了从某一受信的证书签署机构申请签名证书所需的所有工具, 您可以藉此在 &os; 上运行安全的 web 服务器。 如果您未曾安装 Apache, 也可以直接安装一份包含了 mod_ssl 的版本的 Apache 1.3.X, 其方法是通过 www/apache13-modssl port 来进行。 SSL 支持已经作为 Apache 2.X 的一部分提供, 您可以通过 www/apache22 port 来安装后者。 语言绑定 Apache对于一些主要的脚本语言都有相应的模块。 这些模块使得完全使用某种脚本语言来写 Apache 模块成为可能。 他们通常也被嵌入到服务器作为一个常驻内存的解释器, 以避免启动一个外部解释器对于下一节将描述的动态网站所需时间和资源上的开销。 动态网站 web servers dynamic 在过去的十年里,越来越多的企业为了增加收益和暴光率而转向了互联网。 这也同时增进了对于互动网页内容的需求。有些公司,比如 µsoft; 推出了基于他们专有产品的解决方案,开源社区也做出了积极的回应。 比较时尚的选择包括 Django,Ruby on Rails, mod_perl, and mod_php. Django Python Django Django 是一个以 BSD 许可证发布的 framework, 能让开发者快速写出高性能高品质的 web 应用程序。 它提供给一个对象关系映射组件,数据类型可以被当 Python 中的对象,和一组丰富的动态数据库访问 API, 使开发者避免了写 SQL 语句。它同时还提供了可扩展的模板系统, 让应用程序的逻辑部分与 HTML 的表现层分离。 Django 依赖与 mod_pythonApache, 和一个可选的 SQL 数据库引擎。 在设置了一些恰当的标志后,FreeBSD 的 Port 系统将会帮助你安装这些必需的依赖库。 安装 Django,Apache2, mod_python3,和 PostgreSQL &prompt.root; cd /usr/ports/www/py-django; make all install clean -DWITH_MOD_PYTHON3 -DWITH_POSTGRESQL 在安装了 Django 和那些依赖的软件之后, 你需要创建一个 Django 项目的目录,然后配置 Apache,当有对于你网站上应用程序的某些指定的 URL 时调用内嵌的 Python 解释器。 Django/mod_python 有关 Apache 部分的配置 你需要在 Apache 的配置文件 httpd.conf 加入以下这几行, 把对某些 URL 的请求传给你的 web 应用程序: <Location "/"> SetHandler python-program PythonPath "['/dir/to/your/django/packages/'] + sys.path" PythonHandler django.core.handlers.modpython SetEnv DJANGO_SETTINGS_MODULE mysite.settings PythonAutoReload On PythonDebug On </Location> Ruby on Rails Ruby on Rails Ruby on Rails 是另外一个开源的 web framework, 提供了一个全面的开发框架,能帮助 web 开发者工作更有成效和快速写出强大的应用。 它能非常容易的从 posts 系统安装。 &prompt.root; cd /usr/ports/www/rubygem-rails; make all install clean mod_perl mod_perl Perl Apache/Perl 集成计划, 将 Perl 程序设计语言的强大功能, 与 Apache HTTP 服务器 紧密地结合到了一起。 通过 mod_perl 模块, 可以完全使用 Perl 来撰写 Apache 模块。 此外, 服务器中嵌入的持久性解释器, 消除了由于启动外部的解释器为 Perl 脚本的启动所造成的性能损失。 mod_perl 通过多种方式提供。 要使用 mod_perl, 应该注意 mod_perl 1.0 只能配合 Apache 1.3 而 mod_perl 2.0 只能配合 Apache 2.X 使用。 mod_perl 1.0 可以通过 www/mod_perl 安装, 而以静态方式联编的版本, 则可以通过 www/apache13-modperl 来安装。 mod_perl 2.0 则可以通过 www/mod_perl2 安装。 Tom Rhodes Written by mod_php mod_php PHP PHP, 也称为 PHP: Hypertext Preprocessor, 是一种特别适合于 Web 开发的通用脚本语言。 它能够很容易地嵌入到 HTML 之中, 其语法接近于 C、 &java;, 以及 Perl, 以期让 web 开发人员的一迅速撰写动态生成的页面。 要获得用于 Apache web 服务器的 PHP5 支持, 可以从安装 lang/php5 port 开始。 在首次安装 lang/php5 port 的时候, 系统会自动显示可用的一系列 OPTIONS (配置选项)。 如果您没有看到菜单, 例如由于过去曾经安装过 lang/php5 port 等等, 可以用下面的命令再次显示配置菜单, 在 port 的目录中执行: &prompt.root; make config 在配置选项对话框中, 选中 APACHE 这一项, 就可以联编出用于与 Apache web 服务器配合使用的可动态加载的 mod_php5 模块了。 由于各式各样的原因 (例如, 出于已经部署的 web 应用的兼容性考虑), 许多网站仍在使用 PHP4。 如果您需要 mod_php4 而不是 mod_php5, 请使用 lang/php4 port。 lang/php4 port 也支持许多 lang/php5 port 提供的配置和编译时选项。 前面我们已经成功地安装并配置了用于支持动态 PHP 应用所需的模块。 请检查并确认您已将下述配置加入到了 /usr/local/etc/apache/httpd.conf 中: LoadModule php5_module libexec/apache/libphp5.so AddModule mod_php5.c <IfModule mod_php5.c> DirectoryIndex index.php index.html </IfModule> <IfModule mod_php5.c> AddType application/x-httpd-php .php AddType application/x-httpd-php-source .phps </IfModule> 这些工作完成之后, 还需要使用 apachectl 命令来完成一次 graceful restart 以便加载 PHP 模块: &prompt.root; apachectl graceful 在未来您升级 PHP 时, make config 这步操作就不再是必需的了; 您所选择的 OPTIONS 会由 &os; 的 Ports 框架自动保存。 在 &os; 中的 PHP 支持是高度模块化的, 因此基本安装的功能十分有限。 增加其他功能的支持非常简单, 只需通过 lang/php5-extensions port 即可完成。 这个 port 提供了一个菜单驱动的界面来帮助完成 PHP 扩展的安装。 另外, 也可以通过对应的 port 来单独安装扩展。 例如, 要将对于 MySQL 数据库服务器的支持加入 PHP5, 只需简单地安装 databases/php5-mysql port。 安装完扩展之后, 必须重新启动 Apache 服务器, 来令其适应新的配置变更: &prompt.root; apachectl graceful Murray Stokely Contributed by 文件传输协议 (FTP) FTP 服务器 纵览 文件传输协议 (FTP) 为用户提供了一个简单的, 与 FTP 服务器交换文件的方法。 &os; 系统中包含了 FTP 服务软件, ftpd。 这使得在 &os; 上建立和管理 FTP 服务器变得非常简单。 配置 最重要的配置步骤是决定允许哪些帐号访问 FTP 服务器。 一般的 &os; 系统包含了一系列系统帐号分别用于执行不同的服务程序, 但未知的用户不应被允许登录并使用这些帐号。 /etc/ftpusers 文件中, 列出了不允许通过 FTP 访问的用户。 默认情况下, 这包含了前述的系统帐号, 但也可以在这里加入其它不应通过 FTP 访问的用户。 您可能会希望限制通过 FTP 登录的某些用户, 而不是完全阻止他们使用 FTP。 这可以通过 /etc/ftpchroot 文件来完成。 这一文件列出了希望对 FTP 访问进行限制的用户和组的表。 而在 &man.ftpchroot.5; 联机手册中, 已经对此进行了详尽的介绍, 故而不再赘述。 FTP 匿名 如果您想要在服务器上启用匿名的 FTP 访问, 则必须建立一个名为 ftp 的 &os; 用户。 这样, 用户就可以使用 ftpanonymous 和任意的口令 (习惯上, 应该是以那个用户的邮件地址作为口令) 来登录和访问您的 FTP 服务器。 FTP 服务器将在匿名用户登录时调用 &man.chroot.2;, 以便将其访问限制在 ftp 用户的主目录中。 有两个文本文件可以用来指定显示在 FTP 客户程序中的欢迎文字。 /etc/ftpwelcome 文件中的内容将在用户连接上之后, 在登录提示之前显示。 在成功的登录之后, 将显示 /etc/ftpmotd 文件中的内容。 请注意后者是相对于登录环境的, 因此对于匿名用户而言, 将显示 ~ftp/etc/ftpmotd 一旦正确地配置了 FTP 服务器, 就必须在 /etc/inetd.conf 中启用它。 这里需要做的全部工作就是将注释符 # 从已有的 ftpd 行之前去掉: ftp stream tcp nowait root /usr/libexec/ftpd ftpd -l 所介绍的那样, 修改这个文件之后, 必须让 inetd 重新加载它, - 才能使新的设置生效。 + 才能使新的设置生效。请参阅 + 以获取更多有关如何在你系统上启用 inetd + 的详细信息。 + + ftpd 也可以作为一个独立的服务启动。 + 这样的话就需要在 /etc/rc.conf + 中设置如下的变量: + + ftpd_enable="YES" + + 在设置了上述变量之后,独立的服务将在下次系统重启的时候启动, + 或者通过以 root 身份手动执行如下的命令启动: + + &prompt.root; /etc/rc.d/ftpd start 现在可以通过输入下面的命令来登录您的 FTP 服务器了: &prompt.user; ftp localhost 维护 syslog 日志文件 FTP ftpd 服务程序使用 &man.syslog.3; 来记录消息。 默认情况下, 系统日志将把和 FTP 相关的消息记录到 /var/log/xferlog 文件中。 FTP 日志的位置, 可以通过修改 /etc/syslog.conf 中如下所示的行来修改: ftp.info /var/log/xferlog FTP 匿名 一定要小心对待在匿名 FTP 服务器中可能遇到的潜在问题。 一般而言, 允许匿名用户上传文件应三思。 您可能发现自己的 FTP 站点成为了交易未经授权的商业软件的论坛, 或发生更糟糕的情况。 如果不需要匿名的 FTP 上传, 可以在文件上配置权限, 使得您能够在其它匿名用户能够下载这些文件之前复查它们。 Murray Stokely Contributed by 为 µsoft.windows; 客户机提供文件和打印服务 (Samba) Samba 服务器 Microsoft Windows 文件服务器 Windows 客户机 打印服务器 Windows 客户机 纵览 Samba 是一个流行的开源软件包, 它提供了针对 µsoft.windows; 客户机的文件和打印服务。 这类客户机可以连接并使用 FreeBSD 系统上的文件空间, 就如同使用本地的磁盘一样, 或者像使用本地打印机一样使用 FreeBSD 上的打印机。 Samba 软件包可以在您的 FreeBSD 安装盘上找到。 如果您没有在初次安装 FreeBSD 时安装 Samba, 则可以通过 net/samba3 port 或 package 来安装。 配置 默认的 Samba 配置文件会以 /usr/local/share/examples/samba/smb.conf.default 的名字安装。这个文件必须复制为 /usr/local/etc/smb.conf 并进行定制, 才能开始使用 Samba smb.conf 文件中包含了 Samba 的运行时配置信息, 例如对于打印机的定义, 以及希望共享给 &windows; 客户机的 共享文件系统Samba 软件包包含了一个称为 swat 的 web 管理工具, 后者提供了配置 smb.conf 文件的简单方法。 使用 Samba Web 管理工具 (SWAT) Samba Web 管理工具 (SWAT) 是一个通过 inetd 运行的服务程序。 因此, 需要把 /etc/inetd.conf 中下面几行的注释去掉, 才能够使用 swat 来配置 Samba swat stream tcp nowait/400 root /usr/local/sbin/swat swat 中所介绍的那样, 在修改了这个配置文件之后, 必须让 inetd 重新加载配置, 才能使其生效。 一旦在 inetd.conf 中启用了 swat, 就可以用浏览器访问 connect to 了。 您将首先使用系统的 root 帐号登录。 只要成功地登录进了 Samba 配置页面, 就可以浏览系统的文档, 或从 Globals(全局) 选项卡开始配置了。 Globals 小节对应于 [global] 小节中的变量, 前者位于 /usr/local/etc/smb.conf 中。 全局配置 无论是使用 swat, 还是直接编辑 /usr/local/etc/smb.conf, 通常首先要配置的 Samba 选项都是: workgroup NT 域名或工作组名, 其他计算机将通过这些名字来找到服务器。 netbios name NetBIOS 这个选项用于设置 Samba 服务器的 NetBIOS 名字。 默认情况下, 这是所在主机的 DNS 名字的第一部分。 server string 这个选项用于设置通过 net view 命令, 以及某些其他网络工具可以查看到的关于服务器的说明性文字。 安全配置 /usr/local/etc/smb.conf 中的两个最重要的配置, 是选定的安全模型, 以及客户机上用户的口令存放后端。 下面的语句控制这些选项: security 最常见的选项形式是 security = sharesecurity = user。 如果您的客户机使用用户名, 并且这些用户名与您的 &os; 机器一致, 一般应选择用户级 (user) 安全。 这是默认的安全策略, 它要求客户机首先登录, 然后才能访问共享的资源。 如果采用共享级 (share) 安全, 则客户机不需要用有效的用户名和口令登录服务器, 就能够连接共享的资源。 这是较早版本的 Samba 中的默认值。 passdb backend NIS+ LDAP SQL 数据库 Samba 提供了若干种不同的验证后端模型。 您可以通过 LDAP、 NIS+、 SQL 数据库, 或经过修改的口令文件, 来完成客户端的身份验证。 默认的验证模式是 smbpasswd, 这也是本章将介绍的全部内容。 假设您使用的是默认的 smbpasswd 后端, 则必须首先创建一个 /usr/local/private/smbpasswd 文件, 来允许 Samba 对客户进行身份验证。 如果您打算让 &unix; 用户帐号能够从 &windows; 客户机上登录, 可以使用下面的命令: &prompt.root; smbpasswd -a username Samba 3.0.23c 开始, 用于存在验证文件的实际目录变成了 /usr/local/etc/samba。 目前推荐使用的后端是 tdbsam, 您应使用下面的命令来添加用户帐号: &prompt.root; pdbedit username 请参考 官方的 Samba HOWTO 以了解关于配置选项的进一步信息。 按照前面给出的基本描述, 您应该已经可以启动 Samba 了。 启动 <application>Samba</application> net/samba3 port 会增加一个新的用于控制 Samba 的启动脚本。 要启用这个脚本, 以便用它来完成启动、 停止或重启 Samba 的任务, 需要在 /etc/rc.conf 文件中加入: samba_enable="YES" 此外, 也可以进行更细粒度的控制: nmbd_enable="YES" smbd_enable="YES" 这也同时配置了在系统引导时启动 Samba 配置好之后, 就可以在任何时候通过下面的命令来启动 Samba 了: &prompt.root; /usr/local/etc/rc.d/samba start Starting SAMBA: removing stale tdbs : Starting nmbd. Starting smbd. 请参见 以了解关于使用 rc 脚本的进一步信息。 Samba 事实上包含了三个相互独立的服务程序。 您应该能够看到 nmbdsmbd 两个服务程序都是通过 samba 脚本启动的。 如果在 smb.conf 中启用了 winbind 名字解析服务, 则应该可以看到 winbindd 服务被启动起来。 可以在任何时候通过下面的命令来停止运行 Samba &prompt.root; /usr/local/etc/rc.d/samba stop Samba 是一个复杂的软件包, 它提供了用于与 µsoft.windows; 网络进行集成的各式各样的功能。 要了解关于这里所介绍的基本安装以外的其它功能, 请访问 Tom Hukins Contributed by 通过 NTP 进行时钟同步 NTP 纵览 随着时间的推移, 计算机的时钟会倾向于漂移。 网络时间协议 (NTP) 是一种确保您的时钟保持准确的方法。 许多 Internet 服务依赖、 或极大地受益于本地计算机时钟的准确性。 例如, web 服务器可能会接收到一个请求, 要求如果文件在某一时刻之后修改过才发送它。 在局域网环境中, 共享文件的计算机之间的时钟是否同步至关重要, 因为这样才能使时间戳保持一致。 类似 &man.cron.8; 这样的程序, 也依赖于正确的系统时钟, 才能够准确地执行操作。 NTP ntpd FreeBSD 附带了 &man.ntpd.8; NTP 服务器, 它可以用于查询其它的 NTP 服务器, 并配置本地计算机的时钟, 或者为其它机器提供服务。 选择合适的 NTP 服务器 NTP 选择服务器 为了同步您的系统时钟, 需要首先找到至少一个 NTP 服务器以供使用。 网络管理员, 或 ISP 都可能会提供用于这样目的的 NTP 服务器—请查看他们的文档以了解是否是这样。 另外, 也有一个在线的 公开的 NTP 服务器列表, 您可以从中选一个较近的 NTP 服务器。 请确认您选择的服务器的访问策略, 如果需要的话, 申请一下所需的许可。 选择多个相互不连接的 NTP 服务器是一个好主意, 这样在某个服务器不可达, 或者时钟不可靠时就可以有别的选择。 这是因为, &man.ntpd.8; 会智能地选择它收到的响应—它会更倾向于使用可靠的服务器。 配置您的机器 NTP 配置 基本配置 ntpdate 如果只想在系统启动时同步时钟, 则可以使用 &man.ntpdate.8;。 对于经常重新启动, 并且不需要经常同步的桌面系统来说这比较适合, 但绝大多数机器都应该运行 &man.ntpd.8;。 在引导时使用 &man.ntpdate.8; 来配合运行 &man.ntpd.8; 也是一个好主意。 &man.ntpd.8; 渐进地修正时钟, 而 &man.ntpdate.8; 则直接设置时钟, 无论机器的当前时间和正确时间有多大的偏差。 要启用引导时的 &man.ntpdate.8;, 需要把 ntpdate_enable="YES" 加到 /etc/rc.conf 中。 此外, 还需要通过 ntpdate_flags 来设置同步的服务器和选项, 它们将传递给 &man.ntpdate.8;。 NTP ntp.conf 一般配置 NTP 是通过 /etc/ntp.conf 文件来进行配置的, 其格式在 &man.ntp.conf.5; 中进行了描述。 下面是一个例子: server ntplocal.example.com prefer server timeserver.example.org server ntp2a.example.net driftfile /var/db/ntp.drift 这里, server 选项指定了使用哪一个服务器, 每一个服务器都独立一行。 如果某一台服务器上指定了 prefer (偏好) 参数, 如上面的 ntplocal.example.com, 则会优先选择这个服务器。 如果偏好的服务器和其他服务器的响应存在显著的差别, 则丢弃它的响应, 否则将使用来自它的响应, 而不理会其他服务器。 一般来说, prefer 参数应该标注在非常精确的 NTP 时源, 例如那些包含特殊的时间监控硬件的服务器上。 driftfile 选项, 则指定了用来保存系统时钟频率偏差的文件。 &man.ntpd.8; 程序使用它来自动地补偿时钟的自然漂移, 从而使时钟即使在切断了外来时源的情况下, 仍能保持相当的准确度。 另外, driftfile 选项也保存上一次响应所使用的 NTP 服务器的信息。 这个文件包含了 NTP 的内部信息, 它不应被任何其他进程修改。 控制您的服务器的访问 默认情况下, NTP 服务器可以被整个 Internet 上的主机访问。 如果在 /etc/ntp.conf 中指定 restrict 参数, 则可以控制允许哪些机器访问您的服务器。 如果希望拒绝所有的机器访问您的 NTP 服务器, 只需在 /etc/ntp.conf 中加入: restrict default ignore 这样做会禁止您的服务器访问在本地配置中列出的服务器。 如果您需要令 NTP 服务器与外界的 NTP 服务器同步时间, 则应允许指定服务器。 请参见联机手册 &man.ntp.conf.5; 以了解进一步的细节。 如果只希望子网内的机器通过您的服务器同步时钟, 而不允许它们配置为服务器, 或作为同步时钟的节点来时用, 则加入 restrict 192.168.1.0 mask 255.255.255.0 nomodify notrap 这里, 需要把 192.168.1.0 改为您网络上的 IP 地址, 并把 255.255.255.0 改为您的子网掩码。 /etc/ntp.conf 可能包含多个 restrict 选项。 要了解进一步的细节, 请参见 &man.ntp.conf.5; 的 Access Control Support(访问控制支持) 小节。 运行 NTP 服务器 要让 NTP 服务器在系统启动时随之开启, 需要把 ntpd_enable="YES" 加入到 /etc/rc.conf 中。 如果希望向 &man.ntpd.8; 传递更多参数, 需要编辑 /etc/rc.conf 中的 ntpd_flags 要在不重新启动机器的前提下启动服务器, 需要手工运行 ntpd, 并带上 /etc/rc.conf 中的 ntpd_flags 所指定的参数。 例如: &prompt.root; ntpd -p /var/run/ntpd.pid 在临时性的 Internet 连接上使用 ntpd &man.ntpd.8; 程序的正常工作并不需要永久性的 Internet 连接。 然而, 如果您的临时性连接是配置为按需拨号的, 那么防止 NTP 通讯频繁触发拨号, 或保持连接就有必要了。 如果您使用用户级 PPP, 可以使用 filter 语句, 在 /etc/ppp/ppp.conf 中进行必要的设置。 例如: set filter dial 0 deny udp src eq 123 # Prevent NTP traffic from initiating dial out set filter dial 1 permit 0 0 set filter alive 0 deny udp src eq 123 # Prevent incoming NTP traffic from keeping the connection open set filter alive 1 deny udp dst eq 123 # Prevent outgoing NTP traffic from keeping the connection open set filter alive 2 permit 0/0 0/0 要了解进一步的信息, 请参考 &man.ppp.8; 的 PACKET FILTERING(包过滤) 小节, 以及 /usr/share/examples/ppp/ 中的例子。 某些 Internet 访问提供商会阻止低编号的端口, 这会导致 NTP 无法正常工作, 因为响应无法到达您的机器。 进一步的信息 关于 NTP 服务器的文档, 可以在 /usr/share/doc/ntp/ 找到 HTML 格式的版本。 + + + + + Tom + Rhodes + Contributed by + + + + + 使用 <command>syslogd</command> 记录远程主机的日志 + + 处理系统日志对于系统安全和管理是一个重要方面。 + 当有多台分布在中型或大型网络的机器,再或者是处于各种不同类型的网络中, + 监视他们上面的日志文件则显得非常难以操作, 在这种情况下, + 配置远程日志记录能使整个处理过程变得更加轻松。 + + 集中记录日志到一台指定的机器能够减轻一些日志文件管理的负担。 + 日志文件的收集, 合并与循环可以在一处配置, + 使用 &os; 原生的工具, 比如 &man.syslogd.8; 和 &man.newsyslog.8;。 + 在以下的配置示例中, 主机 A, 命名为 + logserv.example.com, + 将用来收集本地网络的日志信息。 主机 B, + 命名为 logclient.example.com + 将把日志信息传送给服务器。 在现实中, + 这两个主机都需要配置正确的正向和反向的 DNS + 或者在 /etc/hosts 中记录。 + 否则, 数据将被服务器拒收。 + + + 日志服务器的配置 + + 日志服务器是配置成用来接收远程主机日志信息的机器。 + 在大多数的情况下这是为了方便配置, 或者是为了更好的管理。 + 不论是何原因, 在继续深入之前需要提一些必需条件。 + + 一个正确配置的日志服务器必须符合以下几个最基本的条件: + + + + 服务器和客户端的防火墙规则允许 514 端口上的 + UDP 报文通过。 + + + + syslogd 被配置成接受从远程客户发来的消息。 + + + + syslogd 服务器和所有的客户端都必须有配有正确的正向和反向 + DNS, 或者在 + /etc/hosts 中有相应配置。 + + + + 配置日志服务器, 客户端必须在 + /etc/syslog.conf 中列出, + 并指定日志的 facility: + + +logclient.example.com +*.* /var/log/logclient.log + + + 更多关于各种被支持并可用的 facility + 能在 &man.syslog.conf.5; 手册页中找到。 + + + 一旦加入以后, 所有此类 facility + 消息都会被记录到先前指定的文件 + /var/log/logclient.log + + 最后, 日志文件应该被创建。 不论你用何种方法创建, + 比如 &man.touch.1; 能很好的完成此类任务: + + &prompt.root; touch /var/log/logclient.log + + 此时, 应该重启并确认一下 syslogd + 守护进程: + + &prompt.root; /etc/rc.d/syslogd restart +&prompt.root; pgrep syslog + + 如果返回了一个 PIC 的话, + 服务端应该被成功重启了, 并继续开始配置客户端。 + 如果服务端没有重启的话, 请在 + /var/log/messages + 日志中查阅相关输出。 + + + + 日志客户端配置 + + 日志客户端是一台发送日志信息到日志服务器的机器, + 并在本地保存拷贝。 + + 类似于日志服务器, 客户端也必须满足一些最基本的条件。 + + + + &man.syslogd.8; + 必须被配置成发送指定类型的消息到能接收他们的日志服务器。 + + + + 防火墙必须允许 512 端口上的 UDP 包通过。 + + + + 必须配置正向与反向 DNS, + 或者在 /etc/hosts 中有正确的记录。 + + + + 相比服务器来说配置客户端更轻松一些。 + 客户端的机器在 /etc/rc.conf + 中做如下的设置: + + syslogd_enable="YES" +syslogd_flags="-a logclient.example.com -vv" + + 第一个选项将在机器启动的时候启用 syslogd + 守护进程, 第二行允许在这台服务器上接收从客户端发送来的数据。 + 后面的部分, 使用 增加日志消息的冗长程度。 + 这对于调整 facility 非常有用, + 因为管理能够看见何种消息被发送至哪一级 facility。 + + Facility 是描述某个消息由系统的哪部分生成的。 举例来说, + ftpipfw 都是 facility。 + 当这两项服务生成日志消息时, 它们通常在日志消息中包含了这两种工具。 + Facility 通常带有一个优先级或等级, + 就是用来标记一个日志消息的重要程度。 最普通的为 + warninginfo。 + 请参阅 &man.syslog.3; 手册页以获得一个完整可用的 + facility 与优先级列表。 + + 日志服务器必须在客户端的 /etc/syslog.conf + 中指明。 在此例中, @ + 符号被用来表示发送日志数据到远程的服务器, + 看上去差不多如下这样: + + *.* @logserv.example.com + + 添加后, 必须重启 syslogd + 使得上述修改生效: + + &prompt.root; /etc/rc.d/syslogd restart + + 测试日志消息是否能通过网络发送, + 使用 &man.logger.1; 发送一段消息至 + syslogd + + &prompt.root; logger "Test message from logclient" + + 这段消息现在应该出现在客户和服务端上的 + /var/log/messages + + + + 调试日志服务器 + + 在某些情况下, 如果日志服务器没有收到消息的话就需要调试一番了。 + 有几个可能的原因, 最常见的两个是网络连接的问题和 + DNS 的问题。 为了测试这些问题, + 请确认两边的机器都能使用 /etc/rc.conf + 中所设定的主机名访问到对方。 如果这个能正常工作的话, + 那么就需要对 /etc/rc.conf + 中的 syslogd_flags 选项做些修改了。 + + 在以下的示例中, + /var/log/logclient.log 是空的, + /var/log/message 中也没有表明任何失败的原因。 + 为了增加调试的输出, 修改 ayalogd_flags + 选项至类似于如下的示例, 并重启服务: + + syslogd_flags="-d -a logclien.example.com -vv" + + &prompt.root; /etc/rc.d/syslogd restart + + 在重启服务之后, 屏幕上将立刻闪现类似这样的调试数据: + + logmsg: pri 56, flags 4, from logserv.example.com, msg syslogd: restart +syslogd: restarted +logmsg: pri 6, flags 4, from logserv.example.com, msg syslogd: kernel boot file is /boot/kernel/kernel +Logging to FILE /var/log/messages +syslogd: kernel boot file is /boot/kernel/kernel +cvthname(192.168.1.10) +validate: dgram from IP 192.168.1.10, port 514, name logclient.example.com; +rejected in rule 0 due to name mismatch. + + 很明显,消息是由于主机名不匹配而被拒收的。 + 在一点一点的检查了配置文件之后, 发现了 + /etc/rc.conf 中如下这行有输入错误: + + syslogd_flags="-d -a logclien.example.com -vv" + + 这行应该包涵有 logclient, 而不是 + logclien。 + 在做了正确的修改并重启之后便能见到预期的效果了: + + &prompt.root; /etc/rc.d/syslogd restart +logmsg: pri 56, flags 4, from logserv.example.com, msg syslogd: restart +syslogd: restarted +logmsg: pri 6, flags 4, from logserv.example.com, msg syslogd: kernel boot file is /boot/kernel/kernel +syslogd: kernel boot file is /boot/kernel/kernel +logmsg: pri 166, flags 17, from logserv.example.com, +msg Dec 10 20:55:02 <syslog.err> logserv.example.com syslogd: exiting on signal 2 +cvthname(192.168.1.10) +validate: dgram from IP 192.168.1.10, port 514, name logclient.example.com; +accepted in rule 0. +logmsg: pri 15, flags 0, from logclient.example.com, msg Dec 11 02:01:28 trhodes: Test message 2 +Logging to FILE /var/log/logclient.log +Logging to FILE /var/log/messages + + 此刻, 消息能够被正确接收并保存入文件了。 + + + + 安全性方面的思考 + + 就像其他的网络服务一样, 在实现配置之前需要考虑安全性。 + 有时日志文件也包含了敏感信息, 比如本地主机上所启用的服务, + 用户帐号和配置数据。 从客户端发出的数据经过网络到达服务器, + 这期间既没有加密也没有密码保护。 如果有加密需要的话, + 可以使用 security/stunnel, + 它将在一个加密的隧道中传输数据。 + + 本地安全也同样是个问题。 日志文件在使用中或循环转后都没有被加密。 + 本地用户可能读取这些文件以获得对系统更深入的了解。 + 对于这类情况, 给这些文件设置正确的权限是非常有必要的。 + &man.newsyslog.8; 工具支持给新创建和循环的日志设置权限。 + 把日志文件的权限设置为 600 + 能阻止本地用户不必要的窥探。 + + diff --git a/zh_CN.GB2312/books/handbook/ports/chapter.sgml b/zh_CN.GB2312/books/handbook/ports/chapter.sgml index 633f1673e6..8dc1ce9278 100644 --- a/zh_CN.GB2312/books/handbook/ports/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/ports/chapter.sgml @@ -1,1381 +1,1391 @@ 安装应用程序: Packages 和 Ports 概述 ports packages FreeBSD 将许多系统工具捆绑作为基本系统的一部分。 然而, 要完成实际的工作, 可能还需要安装更多的第三方应用。 FreeBSD 提供了两种补充的技术, 用以在您的系统中安装第三方软件: FreeBSD Ports 套件 (用于从源代码安装), 以及 packages (用以从预编译的二进制版本安装)。 这两种方法都可以用于从本地介质, 或从网上直接安装您喜欢的应用程序的最新版本。 读完这章,您将了解到: 如何安装第三方的二进制软件包。 如何使用 ports 套件从源代码构建第三方软件。 如何删除先前安装的软件包。 如何改动Ports Collection里面的一些参数,定制软件使用。 如何找到您需要的软件包。 如何升级您的应用软件。 软件安装预览 如果您以前使用过 &unix; 系统,那典型的第三方软件安装的步骤是像下面描述的: 下载这个软件,软件的发行版可能是源代码格式,或是一个二进制包。 解开软件(其中代表性的是用 &man.compress.1;, &man.gzip.1;, 或 &man.bzip2.1; 压缩过的tar包)。 阅读相关文档,了解如何安装。 (多半一个文件名是INSTALLREADME, 或在doc/ 目录下的一些文档) 如果软件是以源代码形式发布的,那就需要编译它。可能需要编辑一个 Makefile文件, 或运行 configure脚本,和其他的一些工作。 测试和安装软件。 如果一切顺利的话,就这么简单。如果您在安装一个软件包时发生一些错误, 您可能需要编辑一下它的代码,以使它能正常工作。 您可以继续使用 传统的方式安装软件。 然而, FreeBSD 提供了两种技术: packages 和 ports。 就在写这篇文章的时候, 已经有超过 &os.numports; 个第三方的应用程序可以使用了。 对于任意一个应用程序包,是一个可以下载的FreeBSD package文件。这个 FreeBSD package包含了编译好的的副本, 还有一些配置文件或文档。 一个下载的包文件可以用 FreeBSD 的包管理命令来操作, 例如 &man.pkg.add.1;,&man.pkg.delete.1;, &man.pkg.info.1; 等等。 可以使用一个简单的命令安装一个新的应用程序。 一个FreeBSD的port是一个可以自动从源代码编译成应用程序的文件集合。 记住,如果您自己来编译的话,需要执行很多步的操作 (解压, 补丁, 编译, 安装)。 这些整理 port 的文件集合包含了系统需要完成这个工作的必需信息。 您可以运行一些简单的命令, 那些源代码就可以自动地下载, 解开, 打补丁, 编译, 直至安装完成。 实际上,ports 系统也能做出被 pkg_add 的程序包和不久就要讲到的其他包管理命令来安装的软件包。 Packages 和 ports 是互相 依赖 的。 假设您想安装一个依赖于已经安装的特定库的应用程序。 应用程序和那个库都已经应用于 FreeBSD ports 和 packages。 如果您使用 命令或 ports 系统来添加应用程序, 两个都必须注意库是否被安装, 如果没有, 它会自动先安装库。 这里给出的两种技术是很相似的,您可能会奇怪为什么 FreeBSD 会弄出这两种技术。 其实, packages 和 ports 都有它们自己的长处, 使用哪一种完全取决于您自己的喜好。 Package Benefits 一个压缩的 package 通常要比一个压缩的包含源代码的应用程序小得多。 package 不需要进行额外的编译。 对于大型应用程序如 MozillaKDEGNOME 来说这显得尤为重要, 特别是在您的系统资源比较差的情况下。 package不需要您知道如何在FreeBSD上编译软件的详细过程。 Ports Benefits package 在编译时通常使用比较保守的选项, 这是为了保证它们能够运行在大多数的系统上。 通过从 port 安装, 您可以细微调整编译选项来产生适合于处理器的代码 (针对于 Pentium 4 或 AMD 的 Athlon CPU)。 一些软件包已经把与它们相关的能做和不能做的事情的选项都编译进去了。 例如, Apache 可能就配置了很多的选项。 从 port 中安装时, 您不一定要接受默认的选项, 可以自己来设置。 在一些例子中,一个软件有不同的配置存在多个package。 例如, Ghostscript存在 ghostscript package 和 ghostscript-nox11 package两个配置package, 这取决于您是否安装了X11服务器。 这样的调整对package是可能的, 但如果一个应用程序有超过一个或两个不同的编译时间选项时, 就不行了。 一些软件的许可条件禁止采用二进制形式发行。 它们必须带上源代码。 一些人不信任二进制发行形式。 至少有了源代码, (理论上) 可以亲自阅读它,寻找潜在的问题。 如果您要自己对软件打补丁,您就需要有源代码。 一些人喜欢整天围着源代码转, 所以他们喜欢亲自阅读源代码, 修改源代码等等。 保持更新 ports, 订阅邮件列表 &a.ports; 和递交错误报告 &a.ports-bugs;。 安装任何应用程序之前, 应首先检查 上是否有关于您所安装的应用程序的安全问题报告。 您也可以安装 ports-mgmt/portaudit, 它能够自动地检查已经安装的应用程序的漏洞; 此外, 在您安装程序之前它也会首先检查是否存在已知的漏洞。 另外, 您也可以使用 portaudit -F -a 这个命令在安装了某个软件包之后作出检查。 这章的其余部分将介绍在 FreeBSD 上如何使用 packages 和 ports 来安装和管理第三方软件。 寻找您要的应用程序 在您安装任何应用程序之前,需要知道您需要什么,那个应用程序叫什么。 FreeBSD中可用的应用程序正在不断地增长着。幸运的是, 有许多方法可以找到您所需要的程序: FreeBSD站点上有一个可以搜索到的当前所有可用的应用程序列表,在 http://www.FreeBSD.org/ports/。 它分很多种类,您既可以通过程序的名称来搜索(如果您知道名字), 也可以在分类中列出所有可用的应用程序。 FreshPorts Dan Langille 维护着网站 FreshPorts,在 。 FreshPort时刻 追踪 着在 ports 中应用程序的变化。当有任何程序被升级时,他们就会发 email 提醒您。 FreshMeat 如果您不知道您想要的应用程序的名字,可以通过 () 网站来查找, 如果找到了应用程序, 您可以回 FreeBSD 的主站去看一下这个应用程序是否已经被 port 进去了。 如果您知道一个port的准确名字, 但需要知道在哪个类别里面能找到它,您可以使用 &man.whereis.1; 这个命令。简单地输入 whereis filefile 就是您想安装的程序名字。 如果系统找到了它, 您将被告知在它在哪里, 例如: &prompt.root; whereis lsof lsof: /usr/ports/sysutils/lsof 结果告诉我们这个命令lsof (一个系统配置程序)可以在 /usr/ports/sysutils/lsof目录中找到。 你可以使用简单的 &man.echo.1; 语句来查找某个 port 是否存在于 ports 树中。 例如: &prompt.root; echo /usr/ports/*/*lsof* /usr/ports/sysutils/lsof Note that this will return any matched files downloaded into the /usr/ports/distfiles directory. 请注意这条命令将会返回下载到 /usr/ports/distfiles 目录中所有符合条件的文件。 还有另外的一个寻找您需要的port的方法--是用ports collecton 内嵌的搜索机制。要使用这个搜索, 您需要先到 /usr/ports目录下面。 在那个目录里面, 运行make search name=program-nameprogram-name 就是您想寻找的程序名字。 举个例子, 如果您想找 lsof &prompt.root; cd /usr/ports &prompt.root; make search name=lsof Port: lsof-4.56.4 Path: /usr/ports/sysutils/lsof Info: Lists information about open files (similar to fstat(1)) Maint: obrien@FreeBSD.org Index: sysutils B-deps: R-deps: 在输出的内容里面您要特别注意包含 Path: 的这行将告诉您在哪里可以找到这个 port。 如果要安装此 port, 那其他输出的信息不是必须的, 但是还是显示输出了。 为了更深入的搜索,您还可以用 make search key=stringstring就是您想搜索的部分内容。 它将搜索port的名字、 注释, 描述和从属关系, 如果您不知道您想搜索的程序名字, 可以利用它搜索一些关键主题来找到您需要的。 上面说的这些方法, 搜索的关键字没有大小写区分的。 搜索 LSOF的结果将和搜索lsof的结果一样。 Chern Lee Contributed by - 使用Packages系统 + 使用 Package 系统 + + 在 FreeBSD 系统上有几种不同的工具用来管理 package: + + + sysinstall + 能够在一个运行的系统上被调用来安装, 删除和列出已安装的 package。 + 请参阅 安装后的配置获取更多详细信息。 + 以下章节将介绍基于命令行的 package 管理工具。 + - 一个package的安装 + 一个 package 的安装 packages installing pkg_add 您可以用 &man.pkg.add.1; 这个命令从本地文件或网络上的服务器来安装一个 FreeBSD 软件包。 在本地手动下载一个package,并安装它 &prompt.root; ftp -a ftp2.FreeBSD.org Connected to ftp2.FreeBSD.org. 220 ftp2.FreeBSD.org FTP server (Version 6.00LS) ready. 331 Guest login ok, send your email address as password. 230- 230- This machine is in Vienna, VA, USA, hosted by Verio. 230- Questions? E-mail freebsd@vienna.verio.net. 230- 230- 230 Guest login ok, access restrictions apply. Remote system type is UNIX. Using binary mode to transfer files. ftp> cd /pub/FreeBSD/ports/packages/sysutils/ 250 CWD command successful. ftp> get lsof-4.56.4.tgz local: lsof-4.56.4.tgz remote: lsof-4.56.4.tgz 200 PORT command successful. 150 Opening BINARY mode data connection for 'lsof-4.56.4.tgz' (92375 bytes). 100% |**************************************************| 92375 00:00 ETA 226 Transfer complete. 92375 bytes received in 5.60 seconds (16.11 KB/s) ftp> exit &prompt.root; pkg_add lsof-4.56.4.tgz 如果您没有本地package的安装盘 (如 FreeBSD CD-ROM), 可以执行 &man.pkg.add.1; 命令并加上 选项。 这将迫使程序自动决定目标文件的正确格式和版本, 然后自动从一个 FTP 站点寻找和安装 package。 pkg_add &prompt.root; pkg_add -r lsof 上面的例子将下载正确的package, 而不需要用户的干预就可以安装。 如果您想指定 FreeBSD package 的镜像站点, 替换主站点, 就必须相应地设置 PACKAGESITE 这个环境变量, 覆盖原来的设置。 &man.pkg.add.1; 使用 &man.fetch.3; 下载文件, 可以使用多种环境变量, 包含 FTP_PASSIVE_MODEFTP_PROXY, 和 FTP_PASSWORD。 如果您使用 FTP/HTTP 代理或在防火墙后面, 您可能需要设置这些环境变量。 详细的列表请参考 &man.fetch.3;。上述例子中用 lsof 替代了 lsof-4.56.4。 当使用远程安装 Package 的时候软件名字不需要包含版本号。 &man.pkg.add.1; 将自动的找到这个软件最新的版本。 如果您使用 &os.current; 或 &os.stable;版本的FreeBSD, &man.pkg.add.1; 将下载您的应用软件的最新版本。 如果您使用 -RELEASE 版本的 FreeBSD, 它将会获得与您的版本相应的软件包版本。 您可以通过修改环境变量 PACKAGESITE 来改变这一行为。 例如, 如果您运行 &os; 5.4-RELEASE 系统, 默认情况下 &man.pkg.add.1; 将尝试从 ftp://ftp.freebsd.org/pub/FreeBSD/ports/i386/packages-5.4-release/Latest/ 下载预编译的软件包。 如果您希望强制 &man.pkg.add.1; 下载 &os; 5-STABLE 的软件包, 则可以将 PACKAGESITE 设置为 ftp://ftp.freebsd.org/pub/FreeBSD/ports/i386/packages-5-stable/Latest/ 软件包采用 .tgz.tbz 两种格式。您可以在 下面或从 FreeBSD 的发行光盘找到, 它在每一个 4CD 的 FreeBSD 发行版的 /packages目录中。 软件包的设计规划与 /usr/ports 树一致。 每个分类都有自己的目录, 所有的软件包可以在目录 All中找到。 软件包系统的目录结构与ports的设计规划一致; 它们共同构成了整个 package/port。 软件包的管理 packages managing &man.pkg.info.1; 是用于列出已安装的所有软件包列表和描述的程序。 pkg_info &prompt.root; pkg_info cvsup-16.1 A general network file distribution system optimized for CV docbook-1.2 Meta-port for the different versions of the DocBook DTD ... &man.pkg.version.1;是一个用来统计所有安装的软件包版本的工具。 它可以用来比较本地 package 的版本与 ports 目录中的当前版本是否一致。 pkg_version &prompt.root; pkg_version cvsup = docbook = ... 在第二列的符号指出了安装版本的相关时间和本地ports目录树中可用的版本。 符号 含义 = 在本地ports树中与已安装的软件包版本相匹配。 < 已安装的版本要比在ports树中的版本旧。 >已安装的版本要比在ports树中的版本新 (本地的port树可能没有更新)。 ? 已安装的软件包无法在ports索引中找到。 (可能发生这种事情,举个例子, 您早先安装的一个 port 从 port 树中移出或改名了) *软件包有很多版本。 !已安装的软件包在索引中存有记录, 但是由于某些原因 pkg_version 无法比较已安装的软件包与索引中相对应的版本号。 删除一个软件包 pkg_delete packages deleting 要删除先前安装的软件package,只要使用&man.pkg.delete.1; 工具。 &prompt.root; pkg_delete xchat-1.7.1 需要注意的是, &man.pkg.delete.1; 需要提供完整的包名; 如果您只是指定了类似 xchat 而不是 xchat-1.7.1 这样的名字, 则它将拒绝执行操作。 不过, 您可以使用 &man.pkg.version.1; 来了解安装的 package 的版本。 除此之外, 也可以使用通配符: &prompt.root; pkg_delete xchat\* 这时, 所有名字以 xchat 开头的 package 都会被删掉。 其它 所有已安装的 package 信息都保存在 /var/db/pkg 目录下。 安装文件的列表和每个 package 的内容和描述都能在这个目录的相关文件中找到。 使用Ports Collection 下面的几个小节中, 给出了关于如何使用 Ports 套件来在您的系统中安装或卸载程序的介绍。 关于可用的 make targets 以及环境变量的介绍, 可以在 &man.ports.7; 中找到。 获得Ports Collection 在您能使用 ports 之前, 您必须先获得 Ports Collection — 本质上是 /usr/ports 目录下的一堆 Makefile、 补丁和描述文件。 在您安装 FreeBSD 系统的时候, sysinstall 会询问您是否需要安装 Ports Collection。 如果您选择 no, 那您可以用下面的指令来安装 Ports Collection: CVSup 方法 保持您本地 Ports 套件最新的一种快捷的方法, 是使用 CVSup 协议来进行更新。 如果您希望了解更多关于 CVSup 的细节, 请参见 使用 CVSup。 在 &os; 系统里对 CVSup 的实现叫作 csup。 它首次出现在 &os; 6.2中。 对于旧版本的 &os; 用户而言可以通过 port/package 安装 net/csup 在首次运行 csup 之前, 务必确认 /usr/ports 是空的! 如果您之前已经用其他地方安装了一份 Ports 套件, 则 csup 可能不会自动删除已经在上游服务器上删除掉的补丁文件。 运行 csup: &prompt.root; csup -L 2 -h cvsup.FreeBSD.org /usr/share/examples/cvsup/ports-supfile cvsup.FreeBSD.org 改为离您较近的 CVSup 服务器。 请参见 CVSup 镜像 () 中的镜像站点完整列表。 有时可能希望使用自己的 ports-supfile, 比如说, 不想每次都通过命令行来指定所使用的 CVSup 服务器。 这种情况下, 需要以 root 身份将 /usr/share/examples/cvsup/ports-supfile 复制到新的位置, 例如 /root 或您的主目录。 编辑 ports-supfile CHANGE_THIS.FreeBSD.org 修改成离您较近的 CVSup 服务器。 可以参考 CVSup 镜像 () 中的镜像站点完整列表。 接下来按如下的方式运行 csup &prompt.root; csup -L 2 /root/ports-supfile 此后运行 &man.csup.1; 命令将下载最近所进行的改动, 并将它们应用到您的 Ports Collection 上, 不过这一过程并不重新联编您系统上的 ports。 Portsnap 方式 Portsnap 是另一种用于发布 Ports 套件的方法。 它最早从 &os; 6.0 开始引入。 在较早的系统中, 您可以通过 ports-mgmt/portsnap package 来安装它: &prompt.root; pkg_add -r portsnap - 请参见 使用 Portsnap + 请参见 使用 Portsnap 以了解关于全部 Portsnap 功能的详细描述。 如果您使用 &os; 6.1-RELEASE, 或通过 port 或 package 安装了较新版本的 Portsnap 的话, 可以直接跳过这一步。 /usr/ports 将在首次使用 &man.portsnap.8; 命令时自动创建。 而如果您使用的是较早期版本的 Portsnap, 就只能手工创建空的 /usr/ports 目录了。 &prompt.root; mkdir /usr/ports 下载压缩的 Ports 套件快照到 /var/db/portsnap。 您可以根据需要在这之后关闭 Internet 连接。 &prompt.root; portsnap fetch 假如您是首次运行 Portsnap, 则需要将快照释放到 /usr/ports &prompt.root; portsnap extract 如果您已经有装好的 /usr/ports 而您只想更新, 则应执行下面的命令: &prompt.root; portsnap update Sysinstall 方式 这种方法需要使用 sysinstall 从安装介质上安装 Ports 套件。 注意, 安装的将是发布发行版时的旧版 Ports 套件。 如果您能访问 Internet, 应使用前面介绍的方法之一。 root 身份运行 sysinstall (对 &os; 5.2 之前的版本, 应执行 /stand/sysinstall): &prompt.root; sysinstall 用光标向下选择 Configure, 并按 Enter 向下并选择 Distributions, 按 Enter 选择 ports, 并按 Space 选择 Exit, 并按 Enter 选择所希望的安装介质, 例如 CDROM、 FTP, 等等。 选择 Exit 并按 Enter X 退出 sysinstall 安装 Ports ports 安装 当提到 Ports Collection 时, 第一个要说明的就是何谓 skeleton。 简单地说, port skeleton 是让一个程序在 FreeBSD 上简洁地编译并安装的所需文件的最小组合。 每个 port skeleton 包含: 一个 MakefileMakefile 包括好几个部分, 指出应用程序是如何编译以及将被安装在系统的哪些地方。 一个 distinfo 文件。这个文件包括这些信息: 这些文件用来对下载后的文件校验和进行检查 (使用 &man.md5.1; 和 &man.sha256.1;), 来确保在下载过程中文件没有被破坏。 一个 files 目录。 这个目录包括在 FreeBSD 系统上编译和安装程序需要用到的补丁。 这些补丁基本上都是些小文件, 指出特定文件作了哪些修正。 它们都是纯文本的的格式,基本上是这样的 删除第 10 行将第 26 行改为这样 ..., 补丁文件也被称作 diffs, 他们由 &man.diff.1; 程序生成。 这个目录也包含了在编译 port 时要用到的其它文件。 一个 pkg-descr 文件。 这是一个提供更多细节,有软件的多行描述。 一个 pkg-plist 文件。 这是即将被安装的所有文件的列表。它告诉 ports 系统在卸载时需要删除哪些文件。 一些ports还有些其它的文件, 例如 pkg-message。 ports 系统在一些特殊情况下会用到这些文件。 如果您想知道这些文件更多的细节以及 ports 的概要, 请参阅 FreeBSD Porter's Handbook port里面包含着如何编译源代码的指令, 但不包含真正的源代码。 您可以在网上或 CD-ROM 上获得源代码。 源代码可能被开发者发布成任何格式。 一般来说应该是一个被 tar 和 gzip 过的文件, 或者是被一些其他的工具压缩或未压缩的文件。 ports中这个程序源代码标示文件叫 distfile, 安装 &os; port的方法还不止这两种。 您必须使用 root 用户登录后安装 ports。 在安装任何 port 之前, 应该首先确保已经更新到了最新的 Ports Collection, 并检查 中是否有与那个 port 有关的安全问题。 在安装应用程序之前, 可以使用 portaudit 来自动地检查是否存在已知的安全问题。 这个工具同样可以在 Ports Collection (ports-mgmt/portaudit) 中找到。 在安装新的 port 之前, 可以考虑先运行一下 portaudit -F 来抓取最新的漏洞数据库。 在每天的周期性系统安全检察时, 数据库会被自动更新, 并且会在这之后实施安全审计。 欲了解进一步的情况,请参阅 &man.portaudit.1; 和 &man.periodic.8;。 Ports 套件假定您有可用的 Internet 连接。 如果您没有, 则需要将 distfile 手工放到 /usr/ports/distfiles 中。 要开始操作, 首先进入要安装 port 的目录: &prompt.root; cd /usr/ports/sysutils/lsof 一旦进入了 lsof 的目录,您将会看到这个port的结构。 下一步就是 make,或说 联编 这个 port。 只需在命令行简单地输入 make 命令就可轻松完成这一工作。 做好之后,您可以看到下面的信息: &prompt.root; make >> lsof_4.57D.freebsd.tar.gz doesn't seem to exist in /usr/ports/distfiles/. >> Attempting to fetch from ftp://lsof.itap.purdue.edu/pub/tools/unix/lsof/. ===> Extracting for lsof-4.57 ... [extraction output snipped] ... >> Checksum OK for lsof_4.57D.freebsd.tar.gz. ===> Patching for lsof-4.57 ===> Applying FreeBSD patches for lsof-4.57 ===> Configuring for lsof-4.57 ... [configure output snipped] ... ===> Building for lsof-4.57 ... [compilation output snipped] ... &prompt.root; 注意,一旦编译完成,您就会回到命令行。 下一步安装 port, 要安装它只需要在 make 命令后跟上一个单词 install 即可: &prompt.root; make install ===> Installing for lsof-4.57 ... [installation output snipped] ... ===> Generating temporary packing list ===> Compressing manual pages for lsof-4.57 ===> Registering installation for lsof-4.57 ===> SECURITY NOTE: This port has installed the following binaries which execute with increased privileges. &prompt.root; 一旦您返回到提示符,您就可以运行您刚刚安装的程序了。因为 lsof 是一个赋予特殊权限的程序, 因此显示了一个安全警告。 在编译和安装 ports 的时候, 您应该留意任何出现的警告。 删除工作目录是个好主意, 这个目录中包含了全部在编译过程中用到的临时文件。 这些文件不仅会占用宝贵的磁盘空间, 而且可能会给升级新版本的 port 时带来麻烦。 &prompt.root; make clean ===> Cleaning for lsof-4.57 &prompt.root; 使用 make install clean 可以一步完成 makemake installmake clean 这三个分开的步骤的工作。 一些 shell 会缓存环境变量 PATH 中指定的目录里的可执行文件, 以加速查找它们的速度。 如果您使用的是这类 shell, 在安装 port 之后可能需要执行 rehash 命令, 然后才能运行新安装的那些命令。 这个命令可以在类似 tcsh 的 shell 中使用。 对于类似 sh 的 shell, 对应的命令是 hash -r。 请参见您的 shell 的文档以了解进一步的情况。 某些第三方 DVD-ROM 产品, 如 FreeBSD Mall 的 FreeBSD Toolkit 中包含了 distfiles。 这些文件可以与 Ports 套件配合使用。 将 DVD-ROM 挂接到 /cdrom。 如果您使用不同的挂接点, 则应设置 make 变量 CD_MOUNTPTS。 如果盘上有需要的 distfiles, 则会自动使用。 请注意, 少数 ports 并不允许通过 CD-ROM 发行。 这可能是由于下载之前需要填写注册表格, 或者不允许再次发布, 或者有一些其它原因。 如果您希望安装在 CD-ROM 上没有的 port, 就需要在线操作了。 ports 系统使用 &man.fetch.1; 去下载文件, 它有很多可以设置的环境变量, 其中包括 FTP_PASSIVE_MODEFTP_PROXY, 和 FTP_PASSWORD。 如果您在防火墙之后,或使用 FTP/HTTP代理, 您就可能需要设置它们。 完整的说明请看 &man.fetch.3;。 当使用者不是所有时间都能连接上网络, 则可以利用 make fetch。 您只要在顶层目录 (/usr/ports) 下运行这个命令, 所有需要的文件都将被下载。 这个命令也同样可以在下级类别目录中使用, 例如: /usr/ports/net。 注意, 如果一个port有一些依赖的库或其他 port, 它将 下载这些依赖的 port 的 distfile 文件, 如果您想获取所有依赖的 port 的所有 distfile, 请用 fetch-recursive 命令代替 fetch命令。 您可以在一个类别或在顶级目录编译所有的 port, 或者使用上述提到的 make fetch命令。 这样是非常危险的, 因为有一些port不能并存。 或者有另一种可能, 一些port会安装两个不同的文件, 但是却是相同的文件名。 在一些罕见的例子中, 用户可能需要在除了 MASTER_SITES 以外的一个站点(本地已经下载下来的文件)去获得一个文件包。 您可以用以下命令不使用 MASTER_SITES: &prompt.root; cd /usr/ports/directory &prompt.root; make MASTER_SITE_OVERRIDE= \ ftp://ftp.FreeBSD.org/pub/FreeBSD/ports/distfiles/ fetch 在这个例子中,我们把 MASTER_SITES这个选项改为了 ftp.FreeBSD.org/pub/FreeBSD/ports/distfiles/ 一些 port 允许 (或甚至要求) 您指定编译选项来 启用/禁用 应用程序中非必需的功能, 一些安全选项, 以及其他可以订制的内容。 具有代表性的包括 www/mozillasecurity/gpgme、 以及 mail/sylpheed-claws。 如果存在这样的选项, 通常会在编译时给出提示。 改变默认的 Ports 目录 有时, 使用不同的工作临时目录和目标目录可能很有用 (甚至是必要的)。 可以用 WRKDIRPREFIXPREFIX 这两个变量来改变默认的目录。 例如: &prompt.root; make WRKDIRPREFIX=/usr/home/example/ports install 将在 /usr/home/example/ports 中编译 port 并把所有的文件安装到 /usr/local &prompt.root; make PREFIX=/usr/home/example/local install 将在 /usr/ports 编译它并安装到 /usr/home/example/local 当然, &prompt.root; make WRKDIRPREFIX=../ports PREFIX=../local install 将包含两种设置 (没有办法在这一页把它写完, 但您应该已经知道怎么回事了)。 另外, 这些变量也可以作为环境变量来设置。 请参考您的 shell 的联机手册上关于如何设置环境变量的说明。 处理 <command>imake</command> 一些 port 使用 imake (这是 X Window 系统的一部分) 不能正常地配合 PREFIX, 它们会坚持把文件安装到 /usr/X11R6 下面。 类似地, 一些 Perl port 会忽略 PREFIX 并把文件安装到 Perl 的目录中。 让这些 port 尊重 PREFIX 是困难甚至是不可能的事情。 重新配置 Ports 当你在编译某些 ports 的时候,可能会弹出一个基于 ncurses 的菜单来让你来选择一些编译选项。 通常用户都希望能够在一个 port 被编译安装了以后还能再次访问这份菜单以添加删除或修改这些选项。 实际上有很多方法来做这件事情。 一个方法进入那个 port 的目录后键入 make config, 之后便会再次显示出菜单和已选择的项目。 另一个方法是用 make showconfig, 这会给你显示出所有的配置选项。还有一个方法是执行 make rmconfig, 这将删除所有已选择的项目。 有关这些选项更详细的内容请参阅 &man.ports.7;。 卸载已经安装的 Ports ports 卸载 现在您已经了解了如何安装 ports, 并希望进一步了解如何卸载, 特别是在错误地安装了某个 port 之后。我们将卸载前面例子 (假如您没有注意的话, 是 lsof) 中安装的 port。 Ports 可以同 packages 以完全相同的方式 (在 Packages 一节 中进行了介绍) 卸载, 方法是使用 &man.pkg.delete.1; 命令: &prompt.root; pkg_delete lsof-4.57 升级 Ports ports 升级 首先, 使用 &man.pkg.version.1; 命令来列出 Ports Collection 中提供了更新版本的那些 port: &prompt.root; pkg_version -v <filename>/usr/ports/UPDATING</filename> 在您更新了 Ports 套件之后, 在升级 port 之前, 应查看 /usr/ports/UPDATING。 这个文件中介绍了在升级时用户应注意的问题, 以及一些可能需要进行的操作。 这可能包括更改文件格式、 配置文件位置的变动, 以及与先前版本的兼容性等等。 如果 UPDATING 与本书中介绍的内容不同, 请以 UPDATING 为准。 使用 Portupgrade 来更新 Ports portupgrade portupgrade 工具是设计来简化升级已安装的 port 的操作的。 它通过 ports-mgmt/portupgrade port 来提供。 您可以像其它 port 那样, 使用 make install clean 命令来安装它: &prompt.root; cd /usr/ports/ports-mgmt/portupgrade &prompt.root; make install clean 使用 pkgdb -F 命令来扫描已安装的 port 的列表, 并修正其所报告的不一致。 在每次升级之前, 有规律地执行它是个好主意。 运行 portupgrade -a 时, portupgrade 将开始并升级系统中所安装的所有过时的 ports。 如果您希望在每个升级操作时得到确认, 应指定 参数。 &prompt.root; portupgrade -ai 如果您只希望升级某个特定的应用程序, 而非全部可用的 port, 应使用 portupgrade pkgname。 如果 portupgrade 应首先升级指定应用程序的话, 则应指定 参数。 &prompt.root; portupgrade -R firefox 要使用预编译的 package 而不是 ports 来进行安装, 需要指定 。 如果指定了这个选项, portupgrade 会搜索 PKG_PATH 中指定的本地目录, 如果没有找到, 则从远程站点下载。 如果本地没有找到, 而且远程站点也没有成功地下载预编译包, 则 portupgrade 将使用 ports。 要禁止使用 port, 可以指定 &prompt.root; portupgrade -PP gnome2 如果只想下载 distfiles (或者, 如果指定了 的话, 是 packages) 而不想构建或安装任何东西, 可以使用 。 要了解更多细节, 请参考 &man.portupgrade.1;。 使用 Portmanager 来升级 Ports portmanager Portmanager 是另一个用以简化已安装 port 升级操作的工具。 它可以通过 ports-mgmt/portmanager port 安装: &prompt.root; cd /usr/ports/ports-mgmt/portmanager &prompt.root; make install clean 可以通过这个简单的命令来升级所有已安装的 port: &prompt.root; portmanager -u 如果希望 Portmanager 在进行每步操作之前都给出提示, 应使用 参数。 Portmanager 也可以用来在系统中安装新的 ports。 与通常的 make install clean 命令不同,它会在联编和安装您所选择的 port 之前升级所有依赖包。 &prompt.root; portmanager x11/gnome2 如果关于所选 port 的依赖有任何问题, 可以用 Portmanager 来以正确的顺序重新构建它们。 完成之后, 有问题的 port 也将被重新构建。 &prompt.root; portmanager graphics/gimp -f 要了解更多信息, 请参见 &man.portmanager.1;。 使用 Portmaster 升级 Ports portmaster Portmaster 是另外一个用来升级已安装的 ports 的工具。 Portmaster 被设计成尽可能使用 基本 系统中能找到的工具 (它不依赖于其他的 ports) 和 /var/db/pkg/ 中的信息来检测出需要升级的 ports。你可以在 ports-mgmt/portmaster 找到它: &prompt.root; cd /usr/ports/ports-mgmt/portmaster &prompt.root; make install clean Portmaster groups ports into four categories: Portmaster 把 ports 分成4类: Root ports (不依赖其他的 ports,也不被依赖) Trunk ports (不依赖其他的 ports,但是被其他的 ports 依赖) Branch ports (依赖于其他的 ports,同时也被依赖) Leaf ports (依赖于其他的 ports,但不被依赖) 你可以使用 选项列出所有已安装的 ports 和查找存在更新的 ports: &prompt.root; portmaster -L ===>>> Root ports (No dependencies, not depended on) ===>>> ispell-3.2.06_18 ===>>> screen-4.0.3 ===>>> New version available: screen-4.0.3_1 ===>>> tcpflow-0.21_1 ===>>> 7 root ports ... ===>>> Branch ports (Have dependencies, are depended on) ===>>> apache-2.2.3 ===>>> New version available: apache-2.2.8 ... ===>>> Leaf ports (Have dependencies, not depended on) ===>>> automake-1.9.6_2 ===>>> bash-3.1.17 ===>>> New version available: bash-3.2.33 ... ===>>> 32 leaf ports ===>>> 137 total installed ports ===>>> 83 have new versions available 可以使用这个简单的命令升级所有已安装的 ports: &prompt.root; portmaster -a Portmaster 默认在删除一个现有的 port 前会做一个备份包。如果新的版本能够被成功安装, Portmaster 将删除备份。 使用 Portmaster 便不会自动删除备份。加上 选项之后 Portmaster 将进入互动模式, 在升级每个 port 以前提示你给予确认。 如果你在升级的过程中发现了错误,你可以使用 选项升级/重新编译所有的 ports: &prompt.root; portmaster -af 同样你也可以使用 Portmaster 往系统里安装新的 ports,升级所有的依赖关系之后并安装新的 port:&prompt.root; portmaster shells/bash 更多的详细信息请参阅 &man.portmaster.8; Ports 和磁盘空间 ports disk-space 使用 Ports 套件会最终用完磁盘空间。 在通过 ports 联编和安装软件之后,您应记得清理临时的 work 目录, 其方法是使用 make clean 命令。 您可以使用下面的命令来清理整个 Ports 套件: &prompt.root; portsclean -C 随着时间的推移, 您可能会在 distfiles 目录中积累下大量源代码文件。 您可以手工删除这些文件, 也可以使用下面的命令来删除所有 port 都不引用的文件: &prompt.root; portsclean -D 除此之外, 也可以用下列命令删去目前安装的 port 没有使用的源码包文件: &prompt.root; portsclean -DD 这个 portsclean 工具是 portupgrade 套件的一部分。 不要忘记删除那些已经安装, 但已不再使用的 ports。 用于自动完成这种工作的一个好工具是 ports-mgmt/pkg_cutleaves port。 安装之后还要做点什么? 通常,您通过port安装完一个软件后,可以阅读它带的一些文档(如果它包含文档的话), 或需要编辑它的配置文件,来确保这个软件的运行, 或在机器启动的时候启动(如果它是一个服务的话),等等。 对于不同的软件有着不同的配置步骤。不管怎样, 如果您装好了一个软件,但是不知道下一步怎么办的时候, 这些小技巧可能可以帮助您: 使用 &man.pkg.info.1; 命令,它能找到安装了哪些文件,以及装在哪里。 举个例子,如果您安装了 FooPackage version 1.0.0, 那么这个命令 &prompt.root; pkg_info -L foopackage-1.0.0 | less 将显示这个软件包安装的所有文件,您要特别注意在man/目录里面的文件, 它们可能是手册,etc/目录里面的配置文件,以及 doc/目录下面更多的文档。 如果您不确定已经安装好的软件版本,您可以使用这样的命令 &prompt.root; pkg_info | grep -i foopackage 它将会找到所有已安装的软件包名字中包含foopackage 的软件包。 对于其他的查找, 您只需要在命令行中替换 foopackage 一旦一些软件手册已被您确认安装,您可以使用 &man.man.1; 查看它。 同样的,如果有的话,您还可以完整的查看一遍配置文件的示例,以及任何额外的文档。 如果应用软件有网站, 您还可以从网站上找到文档,常见问题的解答,或其他更多。 如果您不知道它们的网站地址,请使用下面的命令 &prompt.root; pkg_info foopackage-1.0.0 一个 WWW: 行, 如果它存在, 它将提供一个这个应用程序的网站URL. Ports 如果需要在服务器启动时运行(就像互联网服务器), 它通常会把一个脚本的样例放入 /usr/local/etc/rc.d 目录。为了保证正确性, 您可以查看这个脚本, 并编辑或更改这个脚本的名字。 详情请看启动服务。 如何处理坏掉的 Ports 如果您发现某个 port 无法正常工作, 有几件事值得尝试, 包括: 问题报告数据库 中查找是否有尚未提交的修正。 如果有, 可以使用所提议的修正。 要求 port 的监护人 (maintainer) 提供帮助。 输入 make maintainer 或阅读 Makefile 查找监护人的电子邮件地址。 请记得把 port 的名字和版本写在邮件里 (Makefile 中的 $FreeBSD:这一行) 并把错误输出的头几行发给 maintainer。 某些 ports 并非一个人维护, 而是写了一个 邮件列表。 许多, 但并非所有 port, 使用类似 freebsd-listname@FreeBSD.org 这样的地址。 请在提出问题时考虑这一点。 特别地, 由 freebsd-ports@FreeBSD.org 监护的 port, 实际上并没有人维护。 订阅这个邮件列表的人们会感谢您提供的修正和支持。 我们一直都需要更多志愿者! 如果您没有得到回应, 则可以使用 &man.send-pr.1; 来提交问题报告 (请参见 如何撰写 FreeBSD 问题报告)。 修正它! Porter 手册 中提供了关于 Ports 基础设施的详细信息, 通过了解这些内容, 您就能修正偶然坏掉的 port, 或甚至提交自己的 port 了! 从较近的 FTP 站点下载一个编译好的安装包。 中央的 package collection 在 ftp.FreeBSD.orgpackages 目录中, 但 在此之前 一定记得先看看 本地镜像 上是否已经有了! 通常情况下这些安装包都可以直接使用, 而且应该比自行编译快一些。 安装过程本身可以通过 &man.pkg.add.1; 来完成。 diff --git a/zh_CN.GB2312/books/handbook/preface/preface.sgml b/zh_CN.GB2312/books/handbook/preface/preface.sgml index d4d3c123c4..87b25770b6 100644 --- a/zh_CN.GB2312/books/handbook/preface/preface.sgml +++ b/zh_CN.GB2312/books/handbook/preface/preface.sgml @@ -1,578 +1,599 @@ 前言 预期的读者 作为 FreeBSD 的新用户,您将会在本手册第一部分找到 FreeBSD 的安装方法,同时逐渐引入概念和习俗来加强 &unix; 基础。 阅读这部分只需要您有探索的精神和接受新概念的能力。 读完这些之后,手册中很漫长的第二部分是 FreeBSD 中系统管理员感兴趣的所有主题的全面参考。 在阅读这些章节的内容时所需要的背景知识都注释在每一章节的大纲里面, 如果需要,可在阅读前进行预习。 要获得附加的信息来源列表,请查阅 - 相对于第二版的改动 + 相对于第三版的改动 + + 目前的在线手册代表了数百位贡献者过去 10 年多所累积的努力成果。 + 以下是自 2004 年出版的两卷第三版之后的一些重要变更: + + + + , &dtrace;, 增加了有关强大的 &dtrace; + 性能分析工具有关的信息。 + + + + , 文件系统支持, + 增加 &os; 上非原生文件系统有关的信息, + 比如 &sun; 的 ZFS。 + + + + , 安全事件审计, + 增加了 &os; 新的审计功能和使用方法。 + + + + , 虚拟化, + 增加了在虚拟化软件上安装 &os; 有关的信息。 + + + + 相对于第二版的改动 (2004) 您目前看到的这本手册的第三版是 FreeBSD 文档计划的成员历时两年完成的顶峰之作。 + 这一版的内容已经增长到需要分成两卷才能印刷出版。 第三版包含了如下的的主要变动: - , 配置和优化, 进行了扩充并增加了关于 ACPI 电源和资源管理, cron 系统实用程序,以及更多的内核优化选项的相关内容。 , 安全 一章增加了虚拟专用网 (VPNs), 文件访问控制表 (ACLs), 以及安全公告的内容。 , 强制访问控制 (MAC) 是这一版新增的章节。 它解释了什么是 MAC, 以及这一机制如何使您的 FreeBSD 系统更安全。 , 存储, 在原有基础上增加了 USB 存储设备, 文件系统快照, 文件系统容限, 基于文件及网络的文件系统, 以及与加密磁盘分区有关的内容。 ,Vinum, 是这一版中的新章节。 描述了如何使用这种提供了设备无关的逻辑磁盘、软件 RAID-0, RAID-1 和 RAID-5 的卷管理系统——Vinum。 ,PPP 和 SLIP 一章中增加了排除故障的说明。 , 电子邮件 一章中增加了关于如何使用其它的邮件传输代理、 SMTP 认证、 UUCP、 fetchmailprocmail、 以及其它进阶内容。 ,网络服务, 是新版中全新的一章。 这一章包括了如何架设 Apache HTTP 服务器ftpd, 以及用于支持 µsoft; &windows; 客户的 Samba。 一些段落来自原先的 , 进阶网络应用 一章。 ,进阶网络应用 一章增加了关于在 FreeBSD 中使用 &bluetooth; 设备, 安装无线网络, 以及使用异步传输模式 (ATM) 网络的内容。 增加了一份词汇表, 用以说明整本书中出现的术语。 对于全书中图表进行了进一步的美化工作。 - 相对于第一版的改变 + 相对于第一版的改变 (2001) 本手册的第二版是 FreeBSD 文档计划的成员历时两年完成的顶峰之作。 第二版包含了如下的的主要变动: 添加了完整的索引。 用图形替换了以前所有用 ASCII 插图。 每个章节添加了标准大纲,列出了该章所包含的信息和读者所应该了解的知识。 内容逻辑地分成三个部分: 起步系统管理附录 (安装 FreeBSD) 新版本中使用了抓屏图片,使新用户更容易的领会正文。 (&unix; 基础)扩充了进程、守护进程和信号的附加信息。 (安装应用程序) 扩充了二进制包管理的附加信息。 (X Window 系统) 新版本中着重介绍使用现代桌面技术例如 &xfree86; 4.x 上的 KDEGNOME (FreeBSD 启动过程)对第一版内容进行扩充。 (存储) 由第一版中两个单独的章节磁盘备份合并而成。 我们认为这两部分作为一个整体比较容易理解。同时 RAID (包括硬件和软件 RAID) 部分也被添加进来。 (串口通信) 对第一版进行完善,并为 FreeBSD 4.x/5.x 做了更新。 (PPP 和 SLIP) 全部更新。 许多新的内容被添加到 (高级网络). (电子邮件)增加了关于配置 sendmail 的信息。 (&linux; 兼容性) 增加了关于安装 &oracle;&sap.r3; 的信息。 第二版中也涵盖了下列主题: 配置和调整()。 多媒体() 本手册的组织 - 这本手册分成了三个逻辑清晰的部分。第一部分 + 这本手册分成了五个逻辑清晰的部分。第一部分 起步 涵盖了 FreeBSD 的安装和基本使用方法。 读者可根据自己的情况按顺序或者跳过一些熟悉的主题来阅读。第二部分 常用操作 涵盖了 FreeBSD 常用的功能, 这部分可以不按顺序阅读。每个部分由一个简明的大纲开始, 这个大纲描述本章节涵盖的内容和读者应该已经知道的知识。 这主要是让读者可以更好的选择感兴趣的章节阅读。第三部分 系统管理 涵盖了 FreeBSD 高级用户所感兴趣的广泛的话题。 第四部分 网络通讯 包括了网络和服务的话题, 而第五部分则是资源信息的附录。 , 介绍 向新用户介绍 FreeBSD。它描述了 FreeBSD 计划的历史、目标和开发模式。 , 安装 本章将会带领用户完成安装过程。一些高级安装主题, 例如如何通过串行控制台安装,也涵盖在内。 , &unix; 基础 本章涵盖了 FreeBSD 操作系统基础命令和功能。 如果熟悉 &linux; 或者其他类 &unix; 操作系统,则可以跳过这章。 , 安装应用程序 本章涵盖如何用 FreeBSD 的 Ports Collection 和标准二进制软件包来安装第三方软件。 , X Window 系统 本章概要地描述了 X Window System 系统并详细地介绍了如何在 FreeBSD 上使用它。 此外他也描述了常用的桌面环境, 例如 KDEGNOME , 桌面应用 列出了一些常用的桌面应用程序,比如 web 浏览器和办公套件, 描述了在 FreeBSD 上如何安装它们。 , 多媒体 展示了如何为您的系统设置声卡和视频回放支持。 也描述了一些简单的音频和视频应用程序。 , 配置 FreeBSD 内核 解释了为什么需要配置一个新内核并提供了配置、 编译、安装自定义内核的详细说明。 , 打印 描绘了 FreeBSD 上打印机管理, 包括横幅页、打印统计,还有初始的设置。 , &linux; 二进制兼容 描述了 FreeBSD 的 &linux; 兼容特性。 也提供了许多流行的 &linux; 应用程序的详细的安装说明, 比如 &oracle;&sap.r3;,还有 &mathematica; , 配置和调整 本章描述了管理员调整 FreeBSD 系统以优化性能时可能用到的一些参数。 也描述了 FreeBSD 中的各种配置文件以及它们所在的位置。 , 启动过程 本章描述 FreeBSD 的启动过程并且解释了如何用配置选项来控制这个过程。 , 用户和基本帐号管理 本章描述了如何创建和操作用户帐号, 同样也论述了设置用户资源限制和其他账号管理任务的方法。 , 安全 描述了保证 FreeBSD 系统安全可以使用的许多工具, 这包括 Kerberos, IPsec 以及 OpenSSH。 , Jail 介绍了 jail 框架, 以及 jail 相对于 &os; 中传统的 chroot 支持的改进。 , 强制访问控制 解释了何谓强制访问控制 (MAC) 以及如何利用这一机制来加强 FreeBSD 系统的安全。 , 安全事件审计 介绍了 &os; 事件审计是什么, 以及如何安装、 配置它, 并检查或监视审计记帐信息。 , 存储 本章描述了怎样用 FreeBSD 来管理存储介质和文件系统,包括物理磁盘、RAID 阵列、光学和磁带媒体、后备存储磁盘以及网络文件系统。 , GEOM 介绍了 FreeBSD 中的 GEOM 框架是什么, 以及如何配置它所支持的各级 RAID。 , 文件系统支持 探讨了 &os; 对非原生文件系统的支持,比如 &sun; 的 Z 文件系统。 , Vinum 本章描述了怎样使用逻辑卷管理器 Vinum。它提供了设备无关的逻辑磁盘和软件 RAID-0、RAID-1 以及 RAID-5。 , 虚拟化 介绍了虚拟化系统提供的功能, 以及如何配合 &os; 使用它们。 , 本地化 本章描述了如何在 FreeBSD 上使用非英语语言。它涵盖了系统和应用程序级的本地化。 - , 最前沿 + , 更新与升级 &os; 介绍了 FreeBSD-STABLE、 - FreeBSD-CURRENT 以及 FreeBSD 发行版本之间的差异。 - 描述了一般用户如何紧跟开发过程并从中受益。 + FreeBSD-CURRENT 以及 FreeBSD 发行版本之间的差异。 + 描述了一般用户如何紧跟开发过程并从中受益。 + 涵盖了如何更新用户的系统至发行版最新安全修正的方法。 - , Dtrace + , &dtrace; - 本章描述了如何在 &os; 上配置和使用 &sun; 的 DTrace 工具. + 本章描述了如何在 &os; 上配置和使用 &sun; 的 &dtrace; 工具. 动态跟踪可以通过实时的系统分析,帮助找出系统性能瓶颈。 - - , 更新 &os; - - 本章描述了最新的用来更新 &os; 系统的工具。基本系统中的 - &man.freebsd-update.8; 和 Ports Collection 中的 - &man.portsnap.8;。 - - , 串行通信 本章解释了如何连接终端和调制解调器到 FreeBSD 系统,包括拨入和拨出连接。 , PPP 和 SLIP 本章描述了如何用 FreeBSD 通过使用 PPP,SLIP 或者基于以太网的 PPP(PPPoE)来连接远程系统。 , 电子邮件 本章解释了一个 email 服务器的不同组成部分并且简单讨论了关于最流行的 mail 服务器软件 sendmail 的配置。 , 网络服务 提供了详细的指引和示范配置文件以说明如何将一台 FreeBSD 机器作为网络文件系统服务器, 域名服务器, 网络信息服务器或时间同步服务器来使用的方法。 , 防火墙 解释了基于软件的防火墙的原理, 并提供了关于配置 FreeBSD 上的几种防火墙的详细说明。 , 高级网络应用 描述了许多关于网络的主题,包括如何在您的局域网中共享 Internet 连接, 高级路由话题, 无线网络, &bluetooth;, ATM, IPv6以及许多高级话题。 , 获取 FreeBSD 列出了获得 FreeBSD 安装 CDROM 或 DVDROM 的不同资源,也提供了允许您自由下载 FreeBSD 的不同 Internet 站点。 , 参考书目 由于本手册触及到了很多不同的主题,因而可能引发您想要获取更多详细的讲解。 参考书目列出了很多写作这本书时参考的好书。 , Internet 上的资源 讲述了很多对 FreeBSD 用户有用的能够提出问题并进行技术交流的关于 FreeBSD 的论坛。 , PGP 公钥 列出了一些 FreeBSD 开发者的 PGP 签名公钥。 本书中使用的一些约定 为了使本书保持一致性和易读性特做了以下约定: 排版约定 斜体 斜体 字用来表示文件名、URLs、强调文字和术语的主流用法。 等宽 等宽 字体用来表示错误信息、 命令、 环境变量、 port 的名字、 主机名、 用户名、 组名、 设备名、 变量名, 以及代码片断。 粗体 粗体 字用来表示应用程序、命令和关键字。 用户输入 按键用粗体来突出于其他文本。 组合键意味着字用‘+’连接时,同时的按下它们,例如: Ctrl Alt Del 表示您应该同时按下 CtrlAltDel 键。 按顺序依次键入的关键字通常是用逗号隔开,例如: Ctrl X , Ctrl S 这意味着用户应该同时按CtrlX,然后同时按 CtrlS 示例 E:\> 开头的例子代表一个 &ms-dos; 命令。除非另有说明,这些命令都可以在一个现代的 µsoft.windows; 命令行窗口环境被执行。 E:\> tools\fdimage floppies\kern.flp A: 以 &prompt.root; 开头的例子代表必须以 FreeBSD 超级用户身份执行的命令。您可以用 root 身份登录来输入这些命令,或者以普通账号登录然后用 &man.su.1; 来获得超级用户权限。 &prompt.root; dd if=kern.flp of=/dev/fd0 以 &prompt.user; 开头的例子代表命令应该被普通账号执行。 除非另有说明, 在设置环境变量和使用的其他 shell 命令均为 C-shell 语法。 &prompt.user; top 致谢 您所看到的这本书是全球几百人努力的结果。 无论他们只是纠正一些错误或提交完整的章节,所有的贡献都是非常有用的。 一些公司通过提供资金让作者专注于文档开发、提供出版资金等等方式来支持文档开发。 其中,BSDi (后并入Wind River Systems) 资助 FreeBSD 文档计划成员来专职改善这本书直到 2000 年三月第一个印刷版 (ISBN 1-57176-241-8) 的出版。Wind River Systems 同时资助其他作者来对输出结构做很多改进和给文章添加一些附加章节。 这项工作结束于 2001 年 11 月印刷第二版 (ISBN 1-57176-303-1)。在 2003-2004 两年中,FreeBSD Mall, 向为改进这本手册以使其第三版印刷版本能够出版的志愿者支付了报酬。 diff --git a/zh_CN.GB2312/books/handbook/serialcomms/chapter.sgml b/zh_CN.GB2312/books/handbook/serialcomms/chapter.sgml index ae4e24ea00..a40f80bb4b 100644 --- a/zh_CN.GB2312/books/handbook/serialcomms/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/serialcomms/chapter.sgml @@ -1,2531 +1,2534 @@ 串口通讯 概述 串口通讯 &unix; 一直都是支持串口通讯的。事实上, 早期的 &unix; 系统就是利用串口线来输入和输出数据的。 那时常见的 终端 包括一个每秒10个字符的串口打印机和键盘, 现在这些已经发生了很大的变化。 这章将介绍一些利用 FreeBSD 进行串口通讯的方法。 读完这章,您将了解到: 如何通过终端连接到您的FreeBSD系统。 如何使用modem拨号到远程主机。 如何允许远程用户通过modem登录到您的系统。 如何从串口控制台引导您的系统。 阅读这章之前,您应当了解: 如何配置和安装一个新的内核 ()。 理解 &unix; 的权限和进程 ()。 准备您打算在 FreeBSD 中使用的串口设备 (modem 或多插口卡)的技术参考手册。 介绍 术语 bits-per-second bps 每秒位— 数据的传输速度 DTE DTE 数据终端设备 — 如您的计算机 DCE DCE 数据通讯设备 — 如您的modem RS-232 RS-232C cables 用于硬件串口通讯的EIA标准 当讨论通讯数据速度的时候,这节不会使用术语 baud。Baud指电气标准传输率,它已经使用了很长时间, 而 bps (bits per second) 才是正确使用的术语 (至少它不会打扰那些爱争吵的家伙)。 线缆和端口 要将 modem 或终端与您的 FreeBSD 系统相连, 您的计算机需要一个串口, 以及用于连接串口设备所需的线缆。 如果您比较熟悉硬件及所需要的电缆, 则可以跳过这节。 线缆 串口线缆有许多不同的种类。 最常见的两种类型是 null-modem 线缆和标准 (直联) RS-232 线缆。 您的硬件说明书中会介绍应使用的线缆种类。 Null-modem线缆 null-modem cable null-modem 电缆会直接传送某些信号, 如 Signal Ground (信号地), 但对其他信号进行交换。 例如, Transmitted Data (数据发送) 引脚是连到另一端 Received Data (数据接收) 引脚的。 也可以自行制作 null-modem 电缆给终端使用 (例如, 为了品质的要求)。 下面的表格展示了 RS-232C 信号, 以及 DB-25 连接器上的引脚。 注意, 标准也要求一根直通引脚 1 到引脚 1 的 保护地 (Protective Ground) 线, 但这通常都被省掉。 某些终端在只有引脚 2、 3 和 7 的时候, 就已经能够正常使用了, 而其他一些, 则需要下面例子中所展示的不同的配置。 DB-25 to DB-25 Null-Modem Cable 信号 引脚 # 引脚 # 信号 SG 7 连接到 7 SG TD 2 连接到 3 RD RD 3 连接到 2 TD RTS 4 连接到 5 CTS CTS 5 连接到 4 RTS DTR 20 连接到 6 DSR DTR 20 连接到 8 DCD DSR 6 连接到 20 DTR DCD 8 连接到 20 DTR
这里还有两种目前比较流行的其他接线方式。 DB-9 到 DB-9 Null-Modem 电缆 信号 引脚 # 引脚 # 信号 RD 2 接到 3 TD TD 3 接到 2 RD DTR 4 接到 6 DSR DTR 4 接到 1 DCD SG 5 接到 5 SG DSR 6 接到 4 DTR DCD 1 接到 4 DTR RTS 7 接到 8 CTS CTS 8 接到 7 RTS
DB-9 到 DB-25 Null-Modem 电缆 信号 引脚 # 引脚 # 信号 RD 2 DB-9 到 DB-25 Null-Modem 电缆 2 TD TD 3 接到 3 RD DTR 4 接到 6 DSR DTR 4 接到 8 DCD SG 5 接到 7 SG DSR 6 接到 20 DTR DCD 1 接到 20 DTR RTS 7 接到 5 CTS CTS 8 接到 4 RTS
当某一段连接器上的一个引脚需要连接到对端的一对引脚时, 通常是将那一对引脚使用一短线连接, 而使用长线接到另一端的那个引脚。 上面的设计似乎更为流行。 在其他变种中 (在 RS-232 Made Easy 这本书中进行了详细介绍) 则是 SG 接 SG, TD 接 RD、 RTS 和 CTS 接 DCD、 DTR 接 DSR, 反之亦然。
标准RS-232C线缆 RS-232C cables 标准的串口电缆会直接传送所有 RS-232C 信号。 也就是说, 一头的 Transmitted Data 引脚, 会直接接到另一头的 Transmitted Data 引脚。 这包括将调制解调器接到您的 FreeBSD 系统上的那种电缆, 同样也适用于某些型号的终端。
端口 串口是FreeBSD主机与终端传输数据的设备。 这节描述了端口的种类和它们在 FreeBSD 上是如何编址的。 端口的种类 有好几种串口。 在采购或制作线缆之前, 您应确认它能够适合您的终端以及 FreeBSD 系统。 绝大多数终端都提供 DB-25 端口。 个人计算机, 也包括运行 FreeBSD 的 PC 机, 通常会有 DB-25 或 DB-9 口。 如果您的 PC 上有多插口串口卡, 则可能有 RJ-12 或 RJ-45 口。 请参见您硬件的文档以了解所用接口的规格。 此外, 您也可以通过观察外观来了解所用的端口。 端口名称Port Names 在FreeBSD中,您可以通过 /dev 目录中的一个记录来访问每个串口。有两种不同的记录: 呼入端口被命名为/dev/ttydN, 这里 N 是端口号,从零开始。 通常,您使用呼入端口作为终端。呼入端口要求数据线使用载波检测 (DCD) 信号来工作。 呼出端口被命名为 /dev/cuadN。 您通常不使用呼出端口作为终端, 只使用modem。 如果串口线或终端不支持载波检测数据传输, 您可以使用呼出端口。 如果您已经连接一个终端到第一个串口 (在 &ms-dos; 上是COM1), 则可以使用 /dev/ttyd0 来作为终端。 如果它是在第二个串口 (COM2), 那就是 /dev/ttyd1,等等。
内核配置 FreeBSD默认支持4个串口。 在&ms-dos;下,这些是 COM1COM2COM3, 和 COM4。 FreeBSD 目前支持 dumb 多口串口卡,如 BocaBoard 1008 和 2016, 以及许多 Digiboard 和 Stallion Technologies 制造的智能多接口卡。 不过, 默认的内核只会寻找标准的COM端口。 要看看您的内核是否支持您的串口,只要在内核启动时查看一下启动信息, 或使用 /sbin/dmesg 命令重新检测内核启动信息。 特别的,寻找以sio字符启动的信息。 如果想只察看包含 sio 一词的消息, 可以使用下面的命令: &prompt.root; /sbin/dmesg | grep 'sio' 例如,在一个带有4个串口的系统上,这些是串口特定的内核启动信息: sio0 at 0x3f8-0x3ff irq 4 on isa sio0: type 16550A sio1 at 0x2f8-0x2ff irq 3 on isa sio1: type 16550A sio2 at 0x3e8-0x3ef irq 5 on isa sio2: type 16550A sio3 at 0x2e8-0x2ef irq 9 on isa sio3: type 16550A 如果内核未能认出所有的串口, 可能需要通过修改 /boot/device.hints 文件来进行一些配置。 此外, 也可以注释或完全删除掉您没有的设备。 请参见 &man.sio.4; 联机手册来了解关于串口, 以及多插口卡配置的进一步细节。 如果您正使用一个在不同版本的 FreeBSD 上的文件请务必小心, 因为设备参数和语法发生了变化。 这里端口 IO_COM1 代替了 0x3f8,端口 IO_COM2 代替了 0x2f8,端口 IO_COM3 代替了 0x3e8,端口 IO_COM4 代替了 0x2e8,这些都是各自端口相应的端口地址。 中断4,3,5,9都是经常用的中断。也要注意有些正常的串口可能 无法 在一些ISA总线的PC上共享中断 (多插口板卡有板载的电子设备,允许在板上所有 16550A 的设备共享一个或两个中断请求)。 设备特殊文件 在内核中, 大多数设备都是通过 设备特殊文件 来访问的, 这些文件一般位于 /dev 目录中。 sio 是通过 /dev/ttydN (呼入) 和 /dev/cuadN (呼出) 设备来访问的。 此外, FreeBSD 也提供了初始化设备 (/dev/ttydN.init/dev/cuadN.init) 以及锁设备 (/dev/ttydN.lock/dev/cuadN.lock)。 初始化设备用于在打开端口时初始化其通讯参数, 例如使用 RTS/CTS 信号进行流控制的调制解调器的 crtscts。 锁设备则用于在端口上提供一个锁标志, 防止用户或程序改变特定的参数; 请参见 &man.termios.4;、 &man.sio.4;, 以及 &man.stty.1; 的联机手册, 以了解关于终端配置、 锁和初始化设备, 以及配置终端参数的详细信息。 串口配置 ttyd cuad ttydN (或 cuadN) 设备是您将要打开的应用程序的一般设备。 当进程打开某个设备时, 它将有一个终端 I/O 设置的默认配置。 您可以在命令行看看这些设置: &prompt.root; stty -a -f /dev/ttyd1 当您修改了这个设备的设置,这个设置会生效,除非设备被关闭。 当它被重新打开时,它将回到默认设置。 要修改默认设置,您可以打开和调整 初始状态 设备的设置。例如, 要为ttyd5 打开 模式,8位通讯和默认的 流控制, 输入: &prompt.root; stty -f /dev/ttyd5.init clocal cs8 ixon ixoff rc files rc.serial 串口设备的系统级初始化, 是由 /etc/rc.d/serial 来控制的。 这个文件会影响串口设备的默认设置。 为了防止应用程序修改某些设置, 应修改 lock state(锁状态) 设备。 例如, 要把 ttyd5 的速率锁定为 57600 bps, 输入: &prompt.root; stty -f /dev/ttyd5.lock 57600 现在,一个打开ttyd5 和设法改变端口速度的应用程序将被固定在57600bit/s。很自然地, 您需要确定初始状态,然后用root帐户锁定状态设备的写入功能。 很显然,您应该只让 root 用户可以初始化或锁定设备的状态。
Sean Kelly Contributed by 终端 终端 当您在计算机控制台或是在一个连接的网络上时, 终端提供了一个方便和低成本的访问 FreeBSD 系统的方法。 这节描述了如何在 FreeBSD 上使用终端。 终端的用法和类型 早期的 &unix; 系统没有控制台。 人们通过将终端连接到计算机的串口来登录和使用程序。 它很像用 modem 和一些终端软件来拨号进入一个远程的系统, 只能执行文本的工作。 今天的 PC 已经可以使用高质量的图形了, 但与今天的其他&unix;操作系统一样,建立一个登录会话的能力仍然存在。 通过使用一个终端连接到一个没有使用的串口, 您就能登录和运行任何文本程序或在 X 视窗系统中运行一个 xterm 窗口程序。 对于商业用户,您可以把任何终端连接到 FreeBSD 系统, 然后把它们放在员工的桌面上。 对于家庭用户,则可以使用一台比较老的 IBM PC 或 Macintosh 运行一个终端连接到一台运行 FreeBSD 的高性能机器上。 对于FreeBSD,有三种终端: 哑终端 充当终端的PC X 终端 下面一小节将描述每一种终端。 哑终端 哑终端需要专门的好几种硬件,让您通过串口线连接到计算机。 它们被叫做 是因为它们只能够用来显示, 发送和接收文本。 您不能在它上面运行任何程序。 有好几百种哑终端,包括Digital Equipment Corporation 的VT-100和Wyse的WY-75。只有几种可以在FreeBSD上工作。 一些高端的终端可以显示图形,但只有某些软件包可以使用这些高级特性。 哑终端被广泛用于那些不需要图形应用的工作中。 充当终端的PC 假如 哑终端 的功能仅限于显示、 发送和接收文本的话, 那么显然任何一台闲置的个人计算机, 都完全能够胜任哑终端的工作。 因此您需要的是合适的线缆, 以及一些在这台计算机上运行的 终端仿真 软件。 这种配置在家庭中应用十分广泛。 例如, 如果您的爱人正忙于在您的 FreeBSD 系统的控制台上工作时, 您就可以将一台功能稍弱的计算机挂在这个 FreeBSD 系统上来同时完成一些文本界面的工作。 在 &os; 的基本系统中至少有两个能用于进行串口连接的工具: &man.cu.1; 和 &man.tip.1;。 如果要从运行 &os; 的计算机上通过串口连接到另一系统, 可以使用: &prompt.root; cu -l 串口设备 此处 串口设备 表示您计算机上某个串口对应的设备名。 /dev/cuadN 此处的 N 表示串口的编号。 请注意在 &os; 中设备的编号是从零而非一开始的 (这一点与另一些系统, 如基于 &ms-dos; 的系统不同)。 因此, 在基于 &ms-dos; 系统中的 COM1 在 &os; 中通常叫做 /dev/cuad0 其他一些人可能喜欢使用另一些来自 Ports 套件的程序。 Ports 中提供了几个与 &man.cu.1; 和 &man.tip.1; 类似的工具, 例如 comms/minicom X 终端 X终端是最复杂的终端系统。它们通常需要使用以太网来连接。 它们能显示任何X应用程序。 我们介绍X终端只是为了感兴趣。然而, 这章不会涉及X终端的安装,配置或使用。 配置 这节描述了您在一个终端上启用一个登录会话时, 需要在 FreeBSD 系统上进行的配置。 假设已经配置好了内核来支持串口, 就可以直接开始连接了。 中曾经提到, init 进程依赖于系统启动时所有的处理控制和初始化。 通过 init 来执行的一些任务将先读取 /etc/ttys文件, 然后在可用的终端上启用一个 getty 进程。 getty 进程可用来阅读一个登录名和启动 login程序。 然而,要为您的FreeBSD系统配置终端,您需要以 root 身份执行下面的步骤: 如果它不在那里, 您需要为串口在 /dev 目录下添加一行记录到 /etc/ttys 指定 /usr/libexec/getty 在端口上运行, 然后从 /etc/gettytab 文件指定适当的 getty 类型。 指定默认的终端类型。 设置端口为 on 确定端口是否为 secure 迫使init 重新读取 /etc/ttys文件。 作为可选的步骤,您可以通过在 /etc/gettytab 中建立一个记录,在第2步创建一个定制的 getty 类型来使用。这章不会介绍如何做。 您可以参考 &man.gettytab.5; 和 &man.getty.8; 的联机手册了解更多信息。 添加一个记录到<filename>/etc/ttys</filename> /etc/ttys文件列出了您 FreeBSD系统上允许登录的所有端口。 例如, 第一个虚拟控制台 ttyv0 在这个文件中有一个记录。 您可以使用这个记录登录进控制台。 这个文件也包含其他虚拟控制台的记录,串口,和伪 ttys 终端。 对于一个硬连线的终端, 只要列出串口的 /dev 记录而不需要 /dev 部分 (例如, /dev/ttyv0 可以被列为 ttyv0)。 默认的 FreeBSD 安装包括一个支持最初四个串口 ttyd0ttyd3/etc/ttys 文件。 如果您从那些端口中某一个使用终端,您不需要添加另一个记录。 在 <filename>/etc/ttys</filename> 中增加终端记录 假设我们连接两个终端给系统: 一个 Wyse-50 和一个老的运行 Procomm 终端软件模拟一个 VT-100 终端的286IBM PC。 在 /etc/ttys 文件中的相应的记录是这样的: ttyd1 "/usr/libexec/getty std.38400" wy50 on insecure ttyd5 "/usr/libexec/getty std.19200" vt100 on insecure 第一部分指定了终端指定文件的名称, 它可以在 /dev中找到。 第二部分是在这行执行的命令,通常是 &man.getty.8;。 getty 初始化然后打开一行,设置速度, 用户名的命令和执行登录程序。 getty 程序在它的命令行接收一个参数 (可选), getty 类型。 一个 getty 类型会在终端行描述一个特征, 像波特率和奇偶校验。 getty 程序从 /etc/gettytab 文件读取这些特征。 文件/etc/gettytab 包含了许多老的和新的终端行记录。 在很多例子中,启动文本 std 的记录将用硬连线终端来工作。 这些记录忽略了奇偶性。 这是一个从110到115200 bit/s的 std 记录。 当然,您可以添加您自己的记录到这个文件。 gettytab 的联机手册提供了更多的信息。 当在/etc/ttys中设置 getty 类型的时候, 确信在终端上的通讯设置匹配。 在我们的例子中, Wyse-50 不使用奇偶性, 用38400 bit/s 来连接。286 PC不使用奇偶性,用19200bit/s来连接。 第三部分是通常连接到那个tty行的终端类型。对于拨号端口, unknowndialup 通常被用在这个地方。 对于硬连线的终端,终端类型不会改变, 所以您可以从termcap数据库文件中放一个真正的终端类型。 在我们的例子中, Wyse-50 使用真正的终端类型, 而运行 Procomm 的286 PC将被设置成在VT-100上的模拟。 如果端口被启用,可以指定第四个部分。在第二部分, 把它放在这儿将执行初始化进程来启动程序 getty。如果您在这部分拖延, 将没有getty,在端口上因此就没有登录。 最后部分被用来指定端口是否安全。 标记一个安全的端口意味着您信任它允许用 root 帐户从那个端口登录。 不安全的端口不允许 root登录。 在一个不安全的端口上, 用户必须用无特权的帐户登录, 然后使用 su 或一个相似的机制来获得超级用户的权限。 重新读取<filename>/etc/ttys</filename>来强制<command>init</command> /etc/ttys文件做一个必要的修改后,您必须发送一个 SIGHUP 信号给初始化进程来迫使它重新读取配置文件,例如: &prompt.root; kill -HUP 1 init 总是系统运行时的第一个进程,因此它总是PID 1。 如果能够正确设置,所有的线缆都是适当的,终端将可以启用了, 然后一个 getty 进程将在每个终端运行, 您将在您的终端上看到登录命令行。 您的连接可能出现的问题 即使您小心翼翼地注意细节,您仍然可能会在设置终端时出错。 这有一个有关问题和解决办法的列表: 没有登录命令出现: 确定终端被嵌入和打开了。如果把一台个人计算机充当一个终端, 确信终端模拟软件运行在正确的串口上。 确信线缆被稳固地连接在终端和 FreeBSD 计算机上。 确信用了正确的电缆。 确定终端和 FreeBSD 的传输速度和奇偶设置已经一致了。 如果您有一个图像显示终端,确信对比度已经调节好了。 如果它是一个可打印的终端,确信纸张和墨水已经就绪了。 确定一个 getty 进程正在运行和服务终端。 例如, 可以用ps 命令得到运行 getty 程序的列表,键入: &prompt.root; ps -axww|grep getty 您将看到一个终端的记录。例如,下面的显示表明一个getty 正在第二个串口 ttyd1 运行, 正在 /etc/gettytab 中使用 std.38400 的记录: 22189 d1 Is+ 0:00.03 /usr/libexec/getty std.38400 ttyd1 如果没有 getty 进程运行, 确信您已经在/etc/ttys中启用了端口。 在修改完/etc/ttys文件后,记得运行 kill -HUP 1 如果 getty 进程确实在运行, 但终端上仍然没有显示出登录提示, 或者虽然显示了单缺不允许您输入, 您的终端或电缆可能不支持硬件握手。 请尝试将 /etc/ttys 中的 std.38400 改为 3wire.38400 (注意在改完 /etc/ttys 之后要 kill -HUP 1)。 3wire 记录和 std 类似, 但忽略硬件握手。 您可能需要在使用 3wire 时减少波特率或启用软件流控制以避免缓冲区溢出。 出现一个 <quote>垃圾</quote> 而不是一个登录命令行 确信终端和 FreeBSD 使用相同的 bit/s 传输率和奇偶校验设置。 检查一下 getty 进程确信当前使用正确的 getty 类型。 如果没有, 编辑/etc/ttys然后运行kill -HUP 1 当键入密码时,字符两个两个出现 将终端 (或终端模拟软件) 从 半双工本地回显 换成 全双工 Guy Helmer Contributed by Sean Kelly Additions by 拨入服务 拨入服务 为拨入服务配置FreeBSD系统与连接到终端是非常相似的,除非您正在使用 modem来拨号而不是终端。 外置vs.内置modem 外置modem看起来很容易拨号。 因为,外置 modem 可以通过储存在非易失性的RAM中的参数来配置, 它们通常提供指示器来显示重要的RS-232信号的状态。 不停闪光的信号灯能给用户留下比较深刻的印象, 而且指示器也可以用来查看modem是否正常地工作。 内置modem通常缺乏非易失性的RAM, 所以对它们的配置可能会限制在通过 DIP 开关来设置。 如果您的内置modem有指示灯,您也很难看得到。 Modem和线缆 modem 如果您使用一个外置的 modem,那您将需要适当的电缆线。 一个标准的串口线应当足够长以至普通的信号能够连接上: 信号名称 缩写 全名 RD 收到数据 (Received Data) TD 传出数据 (Transmitted Data) DTR 数据终端就绪 (Data Terminal Ready) DSR 数据集就绪 (Data Set Ready) DCD 数据载波检测 (Data Carrier Detect) (RS-232 的收到线路信号检测器) SG 信号地 (Signal Ground) RTS 要求发送数据 (Request to Send) CTS 允许对方发送数据 (Clear to Send)
FreeBSD 对速度超过 2400 bps 的情形需要通过 RTSCTS 信号来完成流控制, 通过 CD 信号来检测呼叫响应和挂机, 并通过 DTR 信号来在会话结束时对调制解调器进行复位。 某些电缆在连接时没有提供全部需要的信号, 这会给您带来问题, 例如在挂断时登录会话不消失, 这就有可能是电缆的问题。 与其它类 &unix; 操作系统类似, FreeBSD 使用硬件信号来检测呼叫响应, 以及在挂断时挂断并复位调制解调器。 FreeBSD 避免发送命令给调制解调器, 或监视其状态。 如果您熟悉通过调制解调器来连接基于 PC 的 BBS 系统, 这可能看起来有点难用。
串口的考虑 FreeBSD支持基于 NS8250, NS16450, NS16550 和 NS16550A 的EIA RS-232C通讯接口。 8250和16450设备有单字符缓冲。 16550设备提供了一个 16 个字符的缓冲, 可以提高更多的系统性能。 因为单字符缓冲设备比 16 个字符的缓冲需要更多的系统资源来工作, 所以基于16550A的接口卡可能更好。 如果系统没有活动的串口, 或有较大的负载, 16 字符缓冲的卡对于低错误率的通讯来说更好。 快速预览 getty 对于终端, init 会在每个配置串口上为每个拨入连接产生一个 getty 进程。 例如, 如果一个 modem 被附带在 /dev/ttyd0 中,用命令ps ax可以显示下面这些: 4850 ?? I 0:00.09 /usr/libexec/getty V19200 ttyd0 当用户拨上modem, 并使用它进行连接时, CD 线就会被 modem 认出。 内核注意到载波信号已经被检测到, 需要完成 getty 端口的打开。 getty 发送一个登录:在指定的初始线速度上的命令行。 Getty 会检查合法的字符是否被接收, 在典型的配置中, 如果发现 垃圾getty 就会设法调节线速度,直到它接收到合理的字符。 /usr/bin/login 用户在键入他/她的登录名称后, getty执行/usr/bin/login, 这会要求用户输入密码来完成登录, 然后启动用户的shell。 配置文件 如果希望允许拨入您的 FreeBSD 系统, 在 /etc 目录中有三个系统配置文件需要您关注。 其一是 /etc/gettytab, 其中包含用于 /usr/libexec/getty 服务的配置信息。 其二是 /etc/ttys, 它的作用是告诉 /sbin/init 哪些 tty 设备上应该运行 getty。 最后, 关于端口的初始化命令, 应放到 /etc/rc.d/serial 脚本中。 关于在 &unix; 上配置拨入调制解调器有两种主要的流派。 一种是将本地计算机到调制解调器的 RS-232 接口配置为固定速率。 这样做的好处是, 远程用户总能立即见到系统的登录提示符, 而其缺点则是, 系统并不知道用户真实的数据速率是多少, 因而, 类似 Emacs 这样的程序, 也就无法调整它们绘制屏幕的方式, 以便为慢速连接改善响应时间。 另一种流派将调制解调器的 RS-232 接口速率配置为随远程用户的连接速率变化。 例如, 对 V.32bis (14.4 Kbps) 连接, 调制解调器会让自己的 RS-232 接口以 19.2 Kbps 的速率运行, 而 2400 bps 连接, 则会使调制解调器的 RS-232 接口以 2400 bps 的速率运行。 由于 getty 并不能识别具体的调制解调器的连接速率反馈信息, 因此, getty 会以初始速度给出一个 login: 提示, 并检查用户的响应字符。 如果用户看到乱码, 则他们应知道此时应按下 Enter 键, 直到看到可以辨认的提示符为止。 如果数据速率不匹配, 则 getty 会将用户输入的任何信息均视为 乱码, 并尝试以下一种速率来再次给出 login: 提示符。 这一过程可能需要令人作呕地重复下去, 不过一般而言, 用户只要敲一两下键盘就能看到正确的提示符了。 显然, 这种登录过程看起来不如前面所介绍的 锁定速率 方法那样简单明了, 但使用低速连接的用户, 却可以在运行全屏幕程序时得到更好的交互响应。 这一节将尽可能公平地介绍关于配置的信息, 但更着力于介绍调制解调器速率随连接速率变化的配置方法。 <filename>/etc/gettytab</filename> /etc/gettytab /etc/gettytab是一个用来配置 getty 信息的 termcap 风格的文件。 请看看 gettytab 的联机手册了解完整的文件格式和功能列表。 锁定速度的配置 如果您把您的modem的数据通讯率锁定在一个特殊的速度上, 您不需要对 /etc/gettytab 文件作任何变化。 匹配速度的配置 您将需要在 /etc/gettytab 中设置一个记录来告诉 getty 您希望在 modem 上使用的速度。 如果您的 modem 的速率是 2400 bit/s, 则可以使用现有的 D2400 的记录。 # # Fast dialup terminals, 2400/1200/300 rotary (can start either way) # D2400|d2400|Fast-Dial-2400:\ :nx=D1200:tc=2400-baud: 3|D1200|Fast-Dial-1200:\ :nx=D300:tc=1200-baud: 5|D300|Fast-Dial-300:\ :nx=D2400:tc=300-baud: 如果您有一个更高速度的 modem, 必须在 /etc/gettytab 中添加一个记录。 下面是一个让您可以以最高 19.2 Kbit/s 的用在 14.4 Kbit/s的modem上的接口记录: # # Additions for a V.32bis Modem # um|V300|High Speed Modem at 300,8-bit:\ :nx=V19200:tc=std.300: un|V1200|High Speed Modem at 1200,8-bit:\ :nx=V300:tc=std.1200: uo|V2400|High Speed Modem at 2400,8-bit:\ :nx=V1200:tc=std.2400: up|V9600|High Speed Modem at 9600,8-bit:\ :nx=V2400:tc=std.9600: uq|V19200|High Speed Modem at 19200,8-bit:\ :nx=V9600:tc=std.19200: 这样做的结果是 8-数据位, 没有奇偶校验的连接。 上面使用19.2 Kbit/s的连接速度的例子,也可以使用 9600 bit/s (for V.32), 2400 bit/s, 1200 bit/s,300 bit/s, 直到 19.2 Kbit/s。 通讯率的调节使用 nx= (next table) 来实现。 每条线使用一个 tc= (table continuation) 的记录来加速对于一个特殊传输率的标准设置。 如果您有28.8 Kbit/s的modem,或您想使用它的 14.4Kbit/s 模式, 就需要使用一个更高的超过 19.2 Kbit/s 的通讯速度的 modem。 这是一个启动 57.6 Kbit/s 的 gettytab 记录的例子: # # Additions for a V.32bis or V.34 Modem # Starting at 57.6 Kbps # vm|VH300|Very High Speed Modem at 300,8-bit:\ :nx=VH57600:tc=std.300: vn|VH1200|Very High Speed Modem at 1200,8-bit:\ :nx=VH300:tc=std.1200: vo|VH2400|Very High Speed Modem at 2400,8-bit:\ :nx=VH1200:tc=std.2400: vp|VH9600|Very High Speed Modem at 9600,8-bit:\ :nx=VH2400:tc=std.9600: vq|VH57600|Very High Speed Modem at 57600,8-bit:\ :nx=VH9600:tc=std.57600: 如果您的 CPU 速度较低, 或系统的负荷很重, 而且没有 16550A 的串口,您可能会在57.6 Kbit/s 上得到 sio silo错误。 <filename>/etc/ttys</filename> /etc/ttys /etc/ttys文件的配置在 中介绍过。 配置 modem 是相似的, 但我们必须指定一个不同的终端类型。 锁定速度和匹配速度配置的通用格式是: ttyd0 "/usr/libexec/getty xxx" dialup on 上面的第一条是这个记录的设备特定文件 — ttyd0 表示 /dev/ttyd0 是这个 getty 将被监视的文件。 第二条 "/usr/libexec/getty xxx" 是将运行在设备上的进程 init。 第三条,dialup,是默认的终端类型。 第四个参数, on, 指出了线路是可操作的 init。 也可能会有第五个参数, secure, 但它将只被用作拥有物理安全的终端 (如系统终端)。 默认的终端类型可能依赖于本地参考。 拨号是传统的默认终端类型, 以至用户可以定制它们的登录脚本来注意终端什么时候拨号, 和自动调节它们的终端类型。 然而, 作者发现它很容易在它的站点上指定 vt102 作为默认的终端类型, 因为用户刚才在它们的远程系统上使用的是VT102模拟器。 您对/etc/ttys作修改之后,您可以发送 init 进程给一个 HUP 信号来重读文件。您可以使用下面的命令来发送信号: &prompt.root; kill -HUP 1 如果这是您的第一次设置系统, 您可能要在发信号 init 之前等一下, 等到您的 modem 正确地配置并连接好。 锁定速度的配置 对于一个锁定速度的配置,您的 ttys 记录必须有一个为 getty 提供固定速度的记录。 对于一个速度被锁定在 19.2kbit/s 的 modem, ttys 记录是这样的: ttyd0 "/usr/libexec/getty std.19200" dialup on 如果您的 modem 被锁定在一个不同的数据速度, 为 std.speed 使用适当的速度来代替 std.19200。 确信您使用了一个在 /etc/gettytab 中列出的正确的类型。 匹配速度的设置 在一个匹配速度的设置中,您的 ttys 录需要参考在 /etc/gettytab 适当的起始 auto-baud 记录。 例如, 如果您为一个以 19.2 Kbit/s 开始的可匹配速度的 modem 添加上面建议的记录, 您的 ttys 记录可能是这样的: ttyd0 "/usr/libexec/getty V19200" dialup on <filename>/etc/rc.d/serial</filename> rc files rc.serial 高速调制解调器, 如使用 V.32、 V.32bis, 以及 V.34 的那些, 需要使用硬件 (RTS/CTS) 流控制。 您可以在 /etc/rc.d/serial 中增加 stty 命令来在 FreeBSD 内核中, 为调制解调器设置硬件流控制标志。 例如, 在 1 号串口 (COM2) 拨入和拨出设备上配置 termios 标志 crtscts, 可以通过在 /etc/rc.d/serial 增加下面的设置来实现: # Serial port initial configuration stty -f /dev/ttyd1.init crtscts stty -f /dev/cuad1.init crtscts Modem 设置 如果您有一个 modem, 它的参数能被存储在非易失性的 RAM 中, 您将必须使用一个终端程序来设置参数 (比如 &ms-dos; 下的 Telix 或者 FreeBSD 下的 tip)。 使用同样的通讯速度来连接 modem 作为初始速度 getty 将使用和配置 modem 的非易失性 RAM 来适应这些要求: 连接时宣告 CD 操作时宣告 DTR; DTR 消失时挂断线路并复位调制解调器 CTS 传输数据流控制 禁用 XON/XOFF 流控制 RTS 接收数据流控制 宁静模式 (无返回码) 无命令回显 请阅读您 modem 的文档找到您需要用什么命令和 DIP 接口设置。 例如,要在一个 &usrobotics; &sportster; 14400 的外置 modem 上设置上面的参数,可以用下面这些命令: ATZ AT&C1&D2&H1&I0&R2&W 您也可能想要在 modem 上寻找机会调节这个设置, 例如它是否使用 V.42bis 和 MNP5 压缩。 外置 modem 也有一些用来设置的 DIP 开关, 也许您可以使用这些设置作为一个例子: Switch 1: UP — DTR Normal Switch 2: N/A (Verbal Result Codes/Numeric Result Codes) Switch 3: UP — Suppress Result Codes Switch 4: DOWN — No echo, offline commands Switch 5: UP — Auto Answer Switch 6: UP — Carrier Detect Normal Switch 7: UP — Load NVRAM Defaults Switch 8: N/A (Smart Mode/Dumb Mode) 在拨号 modem 上的结果代码应该被 禁用/抑制, 以避免当 getty 在 modem 处于命令模式并回显输入时错误地给出 login: 提示时可能造成的问题。 这样可能导致 getty 与 modem 之间产生更长的不必要交互。 锁定速度的配置 对于锁定速度的配置, 您需要配置 modem 来获得一个不依赖于通讯率的稳定的 modem到计算机 的传输率。 在一个 &usrobotics; &sportster; 14400 外置 modem 上, 这些命令将锁定 modem 到计算机 的传输率: ATZ AT&B1&W 匹配速度的配置 对于一个变速的配置, 您需要配置 modem 调节它的串口传输率匹配接收的传输率。 在一个 &usrobotics; &sportster; 14400 的外置 modem 上, 这些命令将锁定 modem 的错误修正传输率适合命令要求的速度, 但允许串口速度适应没有纠错的连接: ATZ AT&B2&W 检查modem的配置 大多数高速的modem提供了用来查看当前操作参数的命令。 在USR Sportster 14400外置modem上, 命令 ATI5 显示了存储在非易失性RAM中的设置。 要看看正确的 modem 操作参数, 可以使用命令 ATZ 然后是 ATI4 如果您有一个不同牌子的 modem, 检查 modem 的使用手册看看如何双重检查您的 modem 的配置参数。 问题解答 这儿是几个检查拨号modem的步骤。 检查FreeBSD系统 把您的modem连接到FreeBSD系统, 启动系统, 然后, 如果您的 modem 有一个指示灯, 当登录时看看 modem 的 DTR 指示灯是否亮: 会在系统控制台出现命令行——如果它亮, 意味着 FreeBSD 已经在适当的通讯端口启动了一个 getty 进程, 等待 modem 接收一个呼叫。 如果DTR指示灯不亮, 通过控制台登录到 FreeBSD系统,然后执行一个 ps ax 命令来看 FreeBSD 是否正在正确的端口运行 getty进程。 您将在进程显示中看到像这样的一行: 114 ?? I 0:00.10 /usr/libexec/getty V19200 ttyd0 115 ?? I 0:00.10 /usr/libexec/getty V19200 ttyd1 如果您看到是这样的: 114 d0 I 0:00.10 /usr/libexec/getty V19200 ttyd0 modem 不接收呼叫, 这意味着 getty 已经在通讯端口打开了。 这可以指出线缆有问题或 modem 错误配置, 因为 getty 无法打开通讯端口。 如果您没有看到任何 getty 进程等待打开想要的 ttydN 端口, 在 /etc/ttys 中双击您的记录看看那儿是否有错误。 另外,检查日志文件 /var/log/messages 看看是否有一些来自 initgetty 的问题日志。 如果有任何信息, 仔细检查配置文件 /etc/ttys/etc/gettytab,还有相应的设备文件 /dev/ttydN, 是否有错误,丢失记录,或丢失了设备指定文件。 尝试接入Try Dialing In 设法拨入系统。 确信使用8位, 没有奇偶检验, 在远程系统上的1阻止位。 如果您不能立刻得到一个命令行, 试试每隔一秒按一下 Enter。 如果您仍没有看到一个登录: 设法发送一个 BREAK。 如果您正使用一个高速的 modem 来拨号, 请在锁定拨号 modem 的接口速度后再试试。 如果您不能得到一个登录:prompt,再检查一下 /etc/gettytab,重复检查: /etc/ttys 中指定的初始可用的名称与 /etc/gettytab 的一个可用的相匹配。 每个 nx= 记录与另一个 gettytab 可用名称匹配。 每个 tc= 记录与另一个 gettytab可用名称相匹配。 如果您拨号但 FreeBSD 系统上的 modem 没有回应, 确信 modem 能回应电话。 如果 modem 看起来配置正确了, 通过检查 modem 的指示灯来确认 DTR 线连接正确。 如果您做了好几次,它仍然无法工作,打断一会,等会再试试。 如果还不能工作, 也许您应该发一封电子邮件给 &a.questions; 寻求帮助。
拨出设备 dial-out service 下面将让您的主机通过 modem 连接到另一台计算机上。 这只要适当地建立一个终端作为远程主机就可以。 这可以用来登录进一个BBS。 如果您用 PPP 有问题, 那这种连接可以用来从 Internet 上下载一个文件。 如果您必须 FTP 一些东西, 而 PPP 断了, 使用终端会话来 FTP 它们。 然后使用 zmodem 来把它们传输到您的机器上。 我的Stock Hayes Modem不被支持,我该怎么办? 事实上, 联机手册对于这个的描述已经过时了。 一个通用的 Hayes拨号已经内建其中。 只要在您的 /etc/remote 文件中使用 at=hayes Hayes 驱动不够 聪明 只能认出一些比较新的 modem 的高级特性 — 如 BUSYNO DIALTONE, 或 CONNECT 115200 的信息将被搞乱。 当您使用的时候, 您必须把这些信息关掉。(通过 ATX0&W)。 另外,拨号的延迟是 60 秒。 您的 modem 可能使用另外的时间或提示认为有其他的通讯问题。 试试 ATS7=45&W 我如何输入这些 AT 命令? /etc/remote /etc/remote 文件中增加一个 direct 项。 举例而言, 如果您的调制解调器挂在第一个串口, 即 /dev/cuad0 上, 则应添加下面这行: cuad0:dv=/dev/cuad0:br#19200:pa=none 此处应使用您的 modem 所支持的最高 br bps 速率。 接下来, 输入 tip cuad0 就可以连到 modem 上了。 此外, 也可以 root 身份执行 cu 命令: &prompt.root; cu -lline -sspeed line 是串口 (例如 /dev/cuad0) 而 speed 则是速率 (如 57600)。 当您输入完 AT 之后, 按 ~. 即可退出。 现在pn <literal>@</literal>标记不能工作? 在电话号码中的 @ 标记告诉计算机在 /etc/phones 文件中查找一个电话号码。 但 @ 标记也是一个在像 /etc/remote 这样的可用文件中的特殊字符。 用一个反斜线符号退出: pn=\@ 我如何在命令行拨电话号码? 在您的 /etc/remote 文件中通常放着一个叫做 generic 的记录。 例如: tip115200|Dial any phone number at 115200 bps:\ :dv=/dev/cuad0:br#115200:at=hayes:pa=none:du: tip57600|Dial any phone number at 57600 bps:\ :dv=/dev/cuad0:br#57600:at=hayes:pa=none:du: 然后, 可以执行: &prompt.root; tip -115200 5551234 如果您更喜欢cu而不是tip,使用一个通用的cu记录: cu115200|Use cu to dial any number at 115200bps:\ :dv=/dev/cuad1:br#57600:at=hayes:pa=none:du: 然后键入: &prompt.root; cu 5551234 -s 115200 这么做时是否每次都需要重新输入 bps 速率? 添加一项 tip1200cu1200, 并将 bps 速率换成更合适的值。 tip 的默认值是1200  bps, 也就是为什么会有 tip1200 这条记录的原因。 虽然您并不需要使用 1200 bps。 我通过一个终端服务器访问了很多主机。 除非每次都要等到您连接到主机然后键入 CONNECT host, 否则使用 tipcm 功能。 例如, 在 /etc/remote 中的这些记录: pain|pain.deep13.com|Forrester's machine:\ :cm=CONNECT pain\n:tc=deep13: muffin|muffin.deep13.com|Frank's machine:\ :cm=CONNECT muffin\n:tc=deep13: deep13:Gizmonics Institute terminal server:\ :dv=/dev/cuad2:br#38400:at=hayes:du:pa=none:pn=5551234: 将让您键入 tip paintip muffin 连接到主机 painmuffin, 和 tip deep13 连接到终端服务器。 <command>tip</command>能为每个站点试用多个线路吗? 经常有一个问题, 一个大学有几个modem线路, 几千个学生设法使用它们。 /etc/remote 中为您的大学添加一个记录, 然后为 pn 功能使用 @ 标记: big-university:\ :pn=\@:tc=dialout dialout:\ :dv=/dev/cuad3:br#9600:at=courier:du:pa=none: 接着, 在 /etc/phones 中列出大学的电话号码: big-university 5551111 big-university 5551112 big-university 5551113 big-university 5551114 tip 将按顺序试用每一个,然后就停止。 如果想继续测试, 隔一段时间再运行 tip 为什么我必须键入 <keycombo action="simul"> <keycap>Ctrl</keycap> <keycap>P</keycap> </keycombo> 两次才能发出 <keycombo action="simul"> <keycap>Ctrl</keycap> <keycap>P</keycap> </keycombo> 一次? CtrlP 是默认的强制字符,被用来告诉 tip 下一个字符是文字的数据。您可以用 ~s 给任何其他的字符设置强制字符,这意思是 设置一个变量 在新的一行键入 ~sforce=single-charsingle-char 是任何简单的字符。 如果您遗漏了 single-char, 那强制字符就是空字符, 这可以键入 Ctrl2 CtrlSpace 来完成。 更好的 single-char Shift Ctrl 6 , 这只用在一些终端服务器上。 通过在您的 $HOME/.tiprc 文件中指定下面这行, 就可以得到您想要的任何强制字符: force=single-char 突然我键入的每一样东西都变成了大写?? 您一定是键入了 Ctrl A , 即 tipraise character, 会临时地指定成坏掉的 caps-lock键。 使用上面的 ~s 来合理地设置各种 raisechar。 事实上, 如果您不想使用这些特性的话,您可以用同样的方法设置强制字符。 这儿有一个很好的示例 .tiprc 文件,对 Emacs用户来说,需要经常按 Ctrl2 CtrlA force=^^ raisechar=^^ ^^ ShiftCtrl6 . 如何用 <command>tip</command> 做文件传输? 如果您正在与另一台 &unix; 系统对话, 您可以用 ~p(put) 和 ~t (take) 发送和接收文件。 这些命令可以在远程系统上运行 catecho 来接收和发送文件。 语法是这样的: ~p local-file remote-file ~t remote-file local-file 由于没有错误校验, 所以您需要使用其他协议, 如 zmodem。 我如何用<command>tip</command>运行zmodem? 要接收这些文件,可以在远程终端启动发送程序。然后,键入 ~C rz 在本地开始接收它们。 要发送文件, 可以在远程终端启动接收程序。 然后, 键入 ~C sz files 把它们发送到远程系统。 Kazutaka YOKOTA Contributed by Bill Paul Based on a document by 设置串口控制台 serial console 介绍 FreeBSD可以通过一个串口只使用一个哑 (dumb) 终端就可以启动一个系统。 这样一种配置只有两种人能使用: 希望在机器上安装 FreeBSD 的系统管理员, 他没有键盘或显示器, 还有就是要调试内核或设备驱动程序的开发人员。 就象 描述的, FreeBSD 采用一个三步的启动过程。 最先两步储存在 FreeBSD 启动磁盘的启动 slice 的启动代码块中。 引导块然后就被加载, 接着运行第三步启动引导器 (/boot/loader)。 为了设置串口控制台, 您必须配置启动代码块, 启动引导器代码和内核。 串口控制台的配置, 简明版 这一节假定您使用默认的配置, 只希望迅速地获得关于配置串口控制台的概览。 使用串口电缆连接 COM1 和控制终端。 要在串口控制台上显示所有的引导信息, 需要以超级用户的身份执行下面的命令: &prompt.root; echo 'console="comconsole"' >> /boot/loader.conf 编辑 /etc/ttys 并把 ttyd0off 改为 ondialup 改为 vt100。 否则通过串口控制台上将不会提示输入口令, 从而导致潜在的安全漏洞。 重新启动并观察是否生效。 如果需要不同的配置, 更进一步的配置讨论可以在 找到。 串口控制台的设置 准备一根串口线缆。 null-modem cable 您需要使用一个 null-modem 的线缆或标准的串口线和一个 null-modem 适配器。 请参考 中有关串口线的讨论。 拔掉键盘。 绝大多数的PC在开机检测的时候会检测到键盘, 如果没有检测到键盘, 则会出现错误。 一些机器会提示缺少键盘, 就不会继续引导系统。 如果您的计算机出现错误, 但仍能继续启动, 您可以不必理它。 如果您的计算机没有键盘拒绝启动, 那您需要配置 BIOS 来避免它。 请参考您的主板的使用说明了解更多细节。 在 BIOS 中将键盘设为 Not installed (未安装)。 现在您仍然无法使用键盘。 这样做只是告诉 BIOS 在启动时不要探测键盘。 您的 BIOS 不应抱怨键盘不存在。 即使这一标志设置为 Not installed 时, 只要把键盘插上, - 它就仍可使用。 + 它就仍可使用。 如果以上的选项不存在于 BIOS 中, + 可尝试寻找 Halt on Error 选项。 + 把这一项设置为 All but Keyboard + 或者是 No Errors, 都能器到相同的作用。 如果系统有 PS/2 鼠标, 如果幸运的话, 您也可以象键盘一样把它拔下来, 这是因为 PS/2 鼠标与键盘的一些硬件是共享的, 您的鼠标插上去, 系统会认为键盘仍在那儿。 插一个哑 (dumb) 终端到COM1:(sio0)。 如果您没有哑终端, 可以使用一个比较老的带有一个 modem 程序的PC/XT机器, 或在其他 &unix; 机器上的串口。 如果您没有 COM1: (sio0), 去找一个。 这时, 您就不能只能选择 COM1:来启动系统。 如果您已经在另一台设备上使用 COM1, 您必须临时删除那个设备, 然后安装一个新的系统引导块和内核。 确信您的内核配置文件已经为 COM1: (sio0) 设置了适当的标记: 有关的标记是: 0x10 启用控制台支持。 如果没有设置它, 则其他的控制台标记都会被忽略。 现在, 绝大多数的设置都有控制台的支持。 这个标记的第一个就是首选的。 这个单独选项是不能确保串口适用于控制台的, 设置下面的标记或加上下面描述的 选项, 和这个放在一起。 0x20 无论是否使用了下面将要讨论的 选项, 都强制这个单元作为控制台 (除非使用了更高优先级的控制台)。 标志 0x20 必须与 一起使用。 0x40 预留这个单元 (配合 0x10) 并让它不能用于普通的使用。 您不应在希望作为控制台的串口单元上设置这个标志。 这一标志是为内核远程调试准备的。 参见 开发者手册 以了解关于远程调试更进一步的情况。 例如: device sio0 at isa? port IO_COM1 flags 0x10 irq 4 看看 &man.sio.4; 的联机手册了解更多信息。 如果标记没有被设置, 您必须运行UserConfig或重新编译内核。 在启动磁盘的 a 分区的根目录创建 boot.config 文件。 这个文件将指导引导块代码如何启动系统。 为了激活串口控制台, 您必须有一个或多个下面的选项——如果您要多个选项, 在同一行必须都包含它们: 切换内部和串口控制台。 您使用这个来交换控制台设备。 例如, 如果您从内部控制台启动, 您可以使用 来直接使用启动引导器和内核来使用串口作为它的控制台设备。 另外, 如果您从串口启动, 您可以使用 来告诉启动引导器和内核使用显示设备作为控制台。 切换单一和双重控制台配置。 在单一配置中, 控制台将是本机的控制台 (显示设备) 或串口。 在双重控制台配置中, 显示设备和串口将同时成为控制台, 无论 的选项的情形。 然而, 双控制台配置只在引导块运行的过程中起作用。 一旦启动引导器获得控制, 由 选项指定的控制台将成为唯一的控制台。 在启动时,探测键盘。如果键盘找不到, 选项会自动设置。 由于当前版本引导块的空间限制, 选项只能探测扩展的键盘。 少于101键的键盘将无法被探测到。 如果您碰到这个情况, 您必须避免使用 选项。 目前还没有绕过这个问题的办法。 使用 选项来自动选择控制台, 或使用 选项来激活控制台。 您也可以使用boot联机文档中所描述的其他选项。 除了 选项, 所有选项将被传给启动引导器 (/boot/loader)。 启动引导器将通过检查 选项的状态来决定是显示设备成为控制台, 还是串口成为控制台。 这表示如果您指定 选项, 但在 /boot.config 中没有 选项, 您在启动代码块时使用串口作为控制台。 启动引导器将使用内部显示设备作为控制台。 启动机器 当您启动您的FreeBSD时,引导块将把 /boot.config 的内容发给控制台。例如: /boot.config: -P Keyboard: no 如果您把 放在 /boot.config 中并指出键盘存在或不存在, 那将只出现第二行。 这些信息会被定位到串口或内部控制台, 或两者同时, 这完全取决于 /boot.config 中的选项。 选项 送出消息的设备 none 内部控制台 串口控制台 串口控制台和内部控制台 串口控制台和内部控制台 , 有键盘 内部控制台 , 无键盘 串口控制台 出现上面信息后, 在引导块加载启动引导器和更多信息被映到屏幕之前将有一个小小的停顿。 在通常情况下,您不需要打断启动进程, 但为了确信设置是否正确,您也可以这样做。 在控制台上按 Enter 以外的任意键就能打断启动进程。 引导块将进入命令行模式。 您将看到: >> FreeBSD/i386 BOOT Default: 0:ad(0,a)/boot/loader boot: 检验上面出现的信息, 可能是串口, 或内部控制台, 或两个同时, 完全取决于您在 /boot.config 中的选项。 如果信息出现在正确的控制台, 按 Enter 继续启动进程。 如果您要使用串口控制台, 但您没有看到命令行, 那可能设置有问题。 这时, 输入 然后按 EnterReturn 来告诉引导块 (然后是启动引导器和内核) 选择串口作为控制台。 一旦系统起来了, 就可以回去检查一下是什么出了问题。 启动引导器加载完后, 您将进入启动进程的第三步, 您仍然可以在启动引导器通过设定您喜欢的环境来切换内部控制台和串口控制台。 参考 摘要 这是几个在这章要讨论的几个设置和选择的控制台的摘要。 例1: 您为 <devicename>sio0</devicename> 设置标记 0x10 device sio0 at isa? port IO_COM1 flags 0x10 irq 4 在 /boot.config 中的选项 引导块执行时所用的控制台 引导加载器执行时所用的控制台 内核所用的控制台 内部 内部 内部 串口 串口 串口 串口和内部 内部 内部 串口和内部 串口 串口 , 有键盘 内部 内部 内部 , 没有键盘 串口和内部 串口 串口 - 例2:您为sio0设置标记为0x30 + 例2:您为 <devicename>sio0</devicename> 设置标记为 0x30 device sio0 at isa? port IO_COM1 flags 0x30 irq 4 在 /boot.config 中的选项 引导块执行时所用的控制台 引导加载器执行时所用的控制台 内核所用的控制台 内部 内部 串口 串口 串口 串口 串口和内部 内部 串口 串口和内部 串口 串口 , 有键盘 内部 内部 串口 , 没有键盘 串口和内部 串口 串口 串口控制台的提示 设置更高的串口速度 在默认配置中, 串口的设置是: 速率 9600 波特、 8 数据位、 无奇偶校验位、 1 停止位。 如果您希望修改默认的控制台速率, 可以采用下列几种方法之一: BOOT_COMCONSOLE_SPEED 配置为希望的速率, 并重新编译引导块。 请参见 以了解如何联编和安装新的引导块。 如果串口控制台已配置为使用 以外的其它方式引导, 或者内核使用的速率与引导块不同, 则必需在内核配置文件中加入下述设置, 并重新联编新内核: options CONSPEED=19200 使用内核引导选项 . 这个命令行选项可以加到 /boot.config 中。 请参见联机手册 &man.boot.8; 以获得如何在 /boot.config 中增加选项, 以及其它的可用选项。 在您的 /boot/loader.conf 文件中启用 comconsole_speed 选项。 使用这个选项时,您还需要在 /boot/loader.conf 中配置 consoleboot_serial, 以及 boot_multicons。 下面是一个利用 comconsole_speed 改变串口控制台速率的例子: boot_multicons="YES" boot_serial="YES" comconsole_speed="115200" console="comconsole,vidconsole" 使用 <devicename>sio0</devicename> 以外的串口 作为控制台 使用串口而不是 sio0 作为控制台需要做一些重编译。 如果您无论如何都要使用另一个串口, 重新编译引导块, 启动引导器和内核。 - 取得内核源代码 (参考 )。 + 取得内核源代码 (参考 )。 编辑 /etc/make.conf 文件, 然后设置 BOOT_COMCONSOLE_PORT作为您要使用 (0x3f80x2f8、 0x3E8 或 0x2E8) 端口的地址。 只有 sio0sio3 (COM1COM4) 都可以使用; 但多口串口卡将不会工作。 不需要任何中断设置。 创建一个定制的内核配置文件, 在您要使用的串口添加合适的标记。 例如, 如果要将 sio1 (COM2) 作为控制台: device sio1 at isa? port IO_COM2 flags 0x10 irq 3 device sio1 at isa? port port IO_COM2 flags 0x30 irq 3 其他端口的控制台标记也不要设。 重新编译和安装引导块: &prompt.root; cd /sys/boot &prompt.root; make clean &prompt.root; make &prompt.root; make install 重建和安装内核。 用 &man.bsdlabel.8; 将引导块写到启动盘上,然后从新内核启动。 通过串口线进入DDB调试器 options BREAK_TO_DEBUGGER options DDB 在串口控制台上得到一个登录命令行 您可能希望通过串口线进入登录提示, 现在您可以看到启动信息, 通过串口控制台键入内核调试信息。可以这样做。 用一个编辑器打开 /etc/ttys 文件, 然后找到下面的行: ttyd0 "/usr/libexec/getty std.9600" unknown off secure ttyd1 "/usr/libexec/getty std.9600" unknown off secure ttyd2 "/usr/libexec/getty std.9600" unknown off secure ttyd3 "/usr/libexec/getty std.9600" unknown off secure ttyd0ttyd3 相当于 COM1COM4。 可以打开或关闭某个端口。 如果您已经改变了串口的速度, 还必须改掉标准的 9600 与当前的例如 19200 相匹配。 您也可以改变终端的类型从不知名的到您串口终端的真实类型。 编辑完这个文件, 您必须 kill -HUP 1 来使这个修改生效。 从启动引导器修改控制台 前面一节描述了如何通过调整引导块来设定串口控制台。 这节将讲到在启动引导器中通过键入一些命令和环境变量来指定控制台。 由于启动引导器会被启动进程的第三步所调用, 引导块以后, 在启动引导器中的设置将忽略在引导块中的设置。 配置串口控制台 您可以很容易地指定启动引导器和内核来使用串口控制台, 只需要在 /boot/loader.ronf中写入下面这行: set console="comconsole" 无论前一节中的引导块如何配置, 这个设置都会生效。 您最好把上面一行放在 /boot/loader.conf 文件的第一行,以便尽早地在启动时看到串口控制台的启动信息。 同样地,您可以指定内部控制台为: set console="vidconsole" 如果您不设置启动引导环境变量控制台, 启动引导器和内核将使用在引导块时用 选项指定的控制台。 控制台可以在 /boot/loader.conf.local 或者是在 /boot/loader.conf 中指定。 看看 &man.loader.conf.5; 的联机手册了解更多信息。 目前, 引导块尚不提供与引导加载器的 选项等价的选项, 另外, 它也不能根据是否有键盘存在自动决定选择使用内部控制台还是串口控制台。 使用串口而不是<devicename>sio0</devicename>作为控制台 要使用一个串口而不是 sio0 作为串口控制台 需要重新编译启动引导器。下面的步骤跟 描述的相似。 警告 这篇文章本意是想告诉人们如何设定没有显示设备或键盘的专用服务器。 不幸的是, 绝大多数系统没有键盘可以让您启动, 而没有显示设备就不让您启动。 使用 AMI BIOS 的机器可以通过在 CMOS 中将 graphics adapter 项设为 Not installed 来在启动时不要求显示适配器。 然而, 许多机器并不支持这个选项, 如果您的系统没有显示硬件就拒绝启动。 对于这些机器, 即使您没有显示器, 也必须在机器上插上显示适配器。 建议您试试采用 AMI BIOS 的机器。
diff --git a/zh_CN.GB2312/books/handbook/updating/chapter.sgml b/zh_CN.GB2312/books/handbook/updating/chapter.sgml deleted file mode 100644 index b8e7e29393..0000000000 --- a/zh_CN.GB2312/books/handbook/updating/chapter.sgml +++ /dev/null @@ -1,477 +0,0 @@ - - - - - - - Tom - Rhodes - Written by - - - - - Colin - Percival - Based on notes provided by - - - - - 更新 &os; - - - 概述 - - Updating FreeBSD - - freebsd-update - Updating - - - 长久以来,&os 操作系统的一个主要方面始终没有改变, - 那就是使用应用程序和工具去获得系统各种大大小小的更新。 - - 多年来用户升级他们的系统,收集安全补丁, - 无损 Ports Collection 更新 ports 和 package - 唯一的选择是使用 CVSup - 工具。 - - 当然原来的 CVSup 仍被支持, - 现在有一个 C 语言的版本加入了 &os;, - 并且有些新的方法能用来获得系统更新。 - - 类似像 &man.portsnap.8; 和 &man.freebsd-update.8; - 这样的工具使得升级过程变得更加简便有效。 - 这些新的方法在提高效率的同时也给用户提供一个简洁的接口。 - 一些新的工具能通过 &man.cron.8; 执行, - 从而减少系统管理员的人为介入,这会有益于那些管理着成百上千台 &os; - 的人。 - - 这一章节将会介绍这些新的方法, - 以及用户跟系统管理如何从这些新方法的实用和易用中获益。 - - 在阅读了这章以后,你将了解: - - - - 哪些工具能被用来更新系统和 Ports Collection。 - - - - 如何使用 freebsd-update - 打安全补丁和完成主要及次要的 &os; 升级。 - - - - 如何比较已安装的系统与原来已知拷贝的状态。 - - - - 在阅读这章之前,你应该: - - - - 了解一些 &unix; 和 &os; 的基础知识 - ()。 - - - - 熟悉基本的内核配置/编译方法 - ()。 - - - - 熟悉使用 Ports Collection 在 &os; - 上安装第三方的应用程序 - ()。 - - - - 熟悉组成 &os; 的各个部分以及使用 - &man.mergemaster.8; 工具 - ()。 - - - - - - FreeBSD 更新 - - 打安全补丁是对于维护计算机软件的一个重要部分, - 特别是对于操作系统。对于 &os; 来说, - 很长的一段时间以来这都不是一件容易的事情。 - 补丁打在源代码上,代码需要被重新编译为二进制, - 然后再重新安装编译后的程序。 - - &os; 引入了 freebsd-update - 工具之后这便不再是问题了。这个工具提供了 2 种功能。 - 第一,它可以把二进制的安全和勘误更新直接应用于 &os; - 的基本系统,而不需要重新编译和安装。第二, - 这个工具还支持主要跟次要的发行版的升级。 - - - 由安全小组支持的各种体系结构和发行版都可使用二进制更新。 - 然而有些特性,比如升级 &os; 操作系统需要最近的 &man.freebsd-update.8; - 和 &os; 6.3。在升级到一个新的发行版本之前, - 应先阅读一下当前发行版的声明, - 因为他们可能包含有关于你期望升级版本的重要消息。 - 这些发行声明可以通过以下链接查阅: - - - - 如果 crontab 中存在有用到 - freebsd-update 特性的部分, - 那么这些在开始以下操作前必须先被禁止。最新版本的 - freebsd-update 可以通过上面的 - URL 下载用 tar - 和 gzip 打包的版本, - 并按照下面的命令安装: - - &prompt.root; gunzip -c freebsd-update-upgrade.tgz | tar xvf - -&prompt.root; mv freebsd-update.sh /usr/sbin/freebsd-update -&prompt.root; mv freebsd-update.conf /etc - - 对于所有当前流行的发行版本来说, - 并不需要下载最新版。 - - - 配置文件 - - 有些用户可能希望调整配置文件来更好的控制升级过程。 - 可用参数的文档非常齐全, - 但下面的这些可能需要进一步的解释: - - # Components of the base system which should be kept updated. -Components src world kernel - - 这个参数是控制 &os; 的哪一部分将被保持更新。 - 默认的是更新源代码,整个基本系统还有内核。 - 这些部件跟安装时的那些相同,举例来说, - 在这里加入 “world/games” 就会允许打入游戏相关的补丁。 - 使用 “src/bin” 则是允许更新 - src/bin - 目录中的源代码。 - - 最好的选择是把这个选项保留为默认值, - 因为如果要修改它去包含一些指定的选项, - 就需要用户列出每一个想要更新的项目。 - 这可能会引起可怕的后果, - 因为部分的源代码和二进制程序得不到同步。 - - # Paths which start with anything matching an entry in an IgnorePaths -# statement will be ignored. -IgnorePaths - - 添加路径,比如 - /bin 或者 - /sbin - 让这些指定的目录在更新过程中不被修改。 - 这个选项能够防止本地的修改被 - freebsd-update 覆盖。 - - # Paths which start with anything matching an entry in an UpdateIfUnmodified -# statement will only be updated if the contents of the file have not been -# modified by the user (unless changes are merged; see below). -UpdateIfUnmodified /etc/ /var/ /root/ /.cshrc /.profile - - 更新指定目录中的未被修改的配置文件。 - 用户的任何修改都会使这些文件的自动更新失效。 - 还有另外一个选项, - KeepModifiedMetadata, - 这个能让 freebsd-update - 在合并时保存修改。 - - # When upgrading to a new &os; release, files which match MergeChanges -# will have any local changes merged into the version from the new release. -MergeChanges /etc/ /var/named/etc/ - - 一个 freebsd-update - 应该尝试合并的配置文件的列表。文件合并的过程是 - 一系列的 &man.diff.1; 补丁类似于更少选项的 &man.mergemaster.8; - 合并的选项是接受,打开一个文本编辑器,或者 - freebsd-update 会被中止。 - 在不能确定的时候,请先备份 /etc - 然后接受合并。更多关于 mergemaster - 的信息请参阅 - - # Directory in which to store downloaded updates and temporary -# files used by &os; Update. -# WorkDir /var/db/freebsd-update - - 这个目录是放置所有补丁和临时文件的。 - 用户做一个版本升级的话,请确认此处至少有 1 GB - 的可用磁盘空间。 - - # When upgrading between releases, should the list of Components be -# read strictly (StrictComponents yes) or merely as a list of components -# which *might* be installed of which &os; Update should figure out -# which actually are installed and upgrade those (StrictComponents no)? -# StrictComponents no - - 当设置成 yes 时, - freebsd-udpate 将假设这个 - Components 列表时完整的, - 并且对此列表以外的项目不会修改。实际上就是 - freebsd-update 会尝试更新 - Componets - 列表里的每一个文件。 - - - - 安全补丁 - - 安全补丁存储在远程的机器上, - 可以使用如下的命令下载并安装: - - &prompt.root; freebsd-update fetch -&prompt.root; freebsd-update install - - 如果给内核打了补丁,那么系统需要重新启动。 - 如果一切都进展顺利,系统就应该被打好了补丁而且 - freebsd-update 可由夜间 - &man.cron.8; 执行。在 /etc/crontab - 中加入以下条目足以完成这项任务: - - @daily root freebsd-update cron - - 这条记录是说明每天运行一次 - freebsd-update。用这种方法, - 使用了 参数, - freebsd-update 仅检查是否存在更新。 - 如果有了新的补丁,就会自动下载到本地的磁盘, - 但不会自动给系统打上。root - 会收到一封电子邮件告知需手动安装补丁。 - - 如果出现了错误,可以使用下面的 - freebsd-update - 命令回退到上一次的修改: - - &prompt.root; freebsd-update rollback - - 完成以后如果内核或任何的内核模块被修改的话, - 就需要重新启动系统。这将使 &os; - 装载新的二进制程序进内存。 - - - freebsd-update 只能应用于 - GENERIC 内核。如果对 - GENERIC - 做了任何修改或者安装了一个自行编译的内核, - freebsd-update - 就无法完成升级 — 如前一个范例那样失败后 - 产生一条错误信息。 - - - - - 重大和次要的更新 - - 这个过程会删除旧的目标文件和库, - 这将使大部分的第三方应用程序无法删除。 - 建议将所有安装的 ports 先删除然后重新安装,或者稍后使用 - ports-mgmt/portupgrade - 工具升级。 大多数用户将会使用如下命令尝试编译: - - &prompt.root; portupgrade -af - - 这将确保所有的东西都会被正确的重新安装。 - 请注意环境变量 BATCH 设置成 - yes 的话将在整个过程中对所有询问回答 - yes,这会帮助在编译过程中免去人工的介入。 - - 重大和次要的更新可以由 - freebsd-update 命令后指定一个发行版本来执行, - 举例来说,下面的命令将帮助你升级到 &os; 6.3: - - &prompt.root; freebsd-update -r 6.3-RELEASE upgrade - - 在这个命令被执行后,freebsd-update - 将会先解析配置文件和评估当前的系统以获得更新系统所需的必要信息。 - 然后便会显示出一个包含了已检测到与未检测到的组件列表。 - 例如: - - Looking up update.FreeBSD.org mirrors... 1 mirrors found. -Fetching metadata signature for 6.3-BETA1 from update1.FreeBSD.org... done. -Fetching metadata index... done. -Inspecting system... done. - -The following components of FreeBSD seem to be installed: -kernel/smp src/base src/bin src/contrib src/crypto src/etc src/games -src/gnu src/include src/krb5 src/lib src/libexec src/release src/rescue -src/sbin src/secure src/share src/sys src/tools src/ubin src/usbin -world/base world/info world/lib32 world/manpages - -The following components of FreeBSD do not seem to be installed: -kernel/generic world/catpages world/dict world/doc world/games -world/proflibs - -Does this look reasonable (y/n)? y - - 此时,freebsd-update - 将会尝试下载所有升级所需的文件。在某些情况下, - 用户可能被问及需安装些什么和如何进行之类的问题。 - - 下载完所有的补丁之后,它们很快就会被打上。 - 这个过程可能会持续一段时间,取决与机器的速度和当前的负载情况。 - 配置文件将会被合并 — 这一部分需要用户的参与, - 因为文件可能被合并或者屏幕上弹出了一个文本编辑器用来手工合并。 - 在处理过程中,每一个成功的合并都会给用户显示出来。 - 失败或者被忽略的合并则会引起合并程序的中止。 - 用户可能想要备份一下 /etc - 之后手工合并重要的文件,比如 - master.passwd 或 - group - - - 系统至此还没有被修改,所有的补丁和合并都在另外一个目录中进行。 - 当所有的补丁都被成功的打上了以后,所有的配置文件都被合并后, - 我们就已经完成了整个升级过程中最困难的部分, - 下面就需要用户来安装这些变更了。 - - - 一旦这个步骤完成后,使用如下的命令将升级后的文件安装到磁盘上。 - - &prompt.root; freebsd-update install - - 内核与内核模块会先被打上补丁。此时机器必须要重新启动。 - 使用下面的命令重启机器,这样新的内核将载入内存: - - &prompt.root; shutdown -r now - - 在系统重新上线后,需要再次运行 freebsd-update。 - 升级的状态被保存着,这样 freebsd-update - 就无需重头开始,但是会删除所有旧的共享库和目标文件。 - 执行如下命令继续这个阶段的升级: - - &prompt.root; freebsd-update install - - - 取决与是否有库的版本更新,通常只有 2 个而不是 - 3 个安装阶段。 - - - 现在需要重新编译和安装第三方软件。 - 这么做的原因是某些已安装的软件可能依赖于在升级过程中已删除的库。 - 可使用 ports-mgmt/portupgrade - 自动化这个步骤,以如下的命令开始: - - &prompt.root; portupgrade -f ruby -&prompt.root; rm /var/db/pkg/pkgdb.db -&prompt.root; portupgrade -f ruby18-bdb -&prompt.root; rm /var/db/pkg/pkgdb.db /usr/ports/INDEX-*.db -&prompt.root; portupgrade -af - - 这个完成了以后,再最后一次运行 - freebsd-update 来结束升级过程。 - 执行如下命令处理升级中的所有细节: - - &prompt.root; freebsd-update install - - 重新启动机器进入新版本的 &os; 升级过程至此就完成了。 - - - - 系统状态对照 - - freebsd-update - 工具也可被用来对着一个已知完好的 &os; 拷贝测试当前的版本。 - 这个选项评估当前的系统工具,库和配置文件。 - 使用以下的命令开始对照: - - &prompt.root; freebsd-update IDS >> outfile.ids - - - 这个命令的名称是 IDS, - 它并不是一个像 - security/snort - 这样的入侵检测系统的替代品。因为 - freebsd-update 在磁盘上存储数据, - 很显然它们有被篡改的可能。 - 当然也可以使用一些方法来降低被篡改的可能性,比如设置 - kern.securelevel 和不使用时把 - freebsd-update - 数据放在只读文件系统上。例如 DVD 或 - 安全存放的外置 USB 磁盘上。 - - - 现在系统将会被检查,生成一份包含了文件和它们的 &man.sha256.1; - 哈希值的清单,有已知发行版中的值与当前系统中安装的值。 - 这就是为什么输出被送到了 outfile.ids 文件。 - 它滚动的太块无法用肉眼对照,而且会很快填满控制台的缓冲区。 - - 这个文件中有非常长的行,但输出的格式很容易分析。 - 举例来说,要获得一份与发行版中不同哈希值的文件列表, - 已可使用如下的命令: - - &prompt.root; cat update.ids | awk '{ print $1 }' | more -/etc/master.passwd -/etc/motd -/etc/passwd -/etc/pf.conf - - 这份输出时删节缩短后的,其实是有更多的文件。 - 其中有些文件并非人为修改,比如 - /etc/passwd - 被修改是因为添加了用户进系统。在某些情况下, - 还有另外的一些文件,诸如内核模块与 - freebsd-update 的不同是因为它们被更新过了。 - 为了指定的文件或目录排除在外,把它们加到 - /etc/freebsd-update.conf 的 - IDSIgnorePaths 选项中。 - - 除了前面讨论过的部分之外, - 这也能被当作是对升级方法的详细补充。 - - - - - Portsnap: 一个 Ports Collection 更新工具 - - &os; 基本系统也包括了一个更新 Ports Collection 的工具: - &man.portsnap.8;。在运行之后,它会连上一个远程网站, - 校验安全密钥,然后下载一份 ports collection 的拷贝。 - 密钥是用来校验所有下载文件的完整性,确保它们在传输是未被修改。 - 使用以下的命令下载最新的 Ports Collection: - - &prompt.root; portsnap fetch -Looking up portsnap.FreeBSD.org mirrors... 3 mirrors found. -Fetching snapshot tag from portsnap1.FreeBSD.org... done. -Fetching snapshot metadata... done. -Updating from Wed Aug 6 18:00:22 EDT 2008 to Sat Aug 30 20:24:11 EDT 2008. -Fetching 3 metadata patches.. done. -Applying metadata patches... done. -Fetching 3 metadata files... done. -Fetching 90 patches.....10....20....30....40....50....60....70....80....90. done. -Applying patches... done. -Fetching 133 new ports or files... done. - - 这个例子展示的是 &man.portsnap.8; - 发现并校验了几个用于当前 ports 的补丁。这还表明以前运行过, - 如果是第一次运行的话,那么仅仅只会下载 Ports Collection。 - - 在 &man.portsnap.8; 成功完成一次 - fetch 操作后,而且本地系统上的 Ports Collection - 和随之而来的补丁通过校验以后。键入以下命令安装更新文件: - - &prompt.root; portsnap extract -/usr/ports/.cvsignore -/usr/ports/CHANGES -/usr/ports/COPYRIGHT -/usr/ports/GIDs -/usr/ports/KNOBS -/usr/ports/LEGAL -/usr/ports/MOVED -/usr/ports/Makefile -/usr/ports/Mk/bsd.apache.mk -/usr/ports/Mk/bsd.autotools.mk -/usr/ports/Mk/bsd.cmake.mk -... - - 至此更新就完成了,然后便可以使用更新后的 - Ports Collection 来安装或升级应用程序。 - - diff --git a/zh_CN.GB2312/books/handbook/vinum/chapter.sgml b/zh_CN.GB2312/books/handbook/vinum/chapter.sgml index a4ca33c091..180aef6967 100644 --- a/zh_CN.GB2312/books/handbook/vinum/chapter.sgml +++ b/zh_CN.GB2312/books/handbook/vinum/chapter.sgml @@ -1,1210 +1,1215 @@ Greg Lehey 原作 Vinum 卷管理程序 概述 无论您有什么样的磁盘,总会有一些潜在问题: 它们可能容量太小。 它们可能速度太慢。 它们可能也太不可靠。 针对这些问题, 人们提出并实现了许多不同的解决方案。 为了应对这些问题, 一些用户采用了多个, 有时甚至是冗余的磁盘这类方法。 除了支持许多种不同的硬件 RAID 控制器之外, FreeBSD 的基本系统中包括了 Vinum 卷管理器, 它是一个用以实现虚拟磁盘驱动器的块设备。 Vinum 是一种称为 卷管理器, 或者说用于解决前面这三种问题的虚拟磁盘驱动程序。 Vinum 能够提供比传统磁盘系统更好的灵活性、 性能和可靠性, 并实现了能够单独或配合使用 RAID-0、 RAID-1 和 RAID-5 模型。 这一章对传统磁盘存储的潜在问题进行了简要说明,并介绍了 Vinum 卷管理器。 从 FreeBSD 5 开始, 对 Vinum 进行了重写, 以便使其符合 GEOM 架构 (), 同时保留其原有的设计创意、 术语, 以及保存在磁盘上的元数据格式。 这一重写的版本称为 gvinum (表示 GEOM vinum)。 接下来的文字中 Vinum 是一个抽象的名字, 通常并不具体指某一特定的实现。 新版本中所有的指令都应通过 gvinum 命令来操作, 而对应的内核模块的名字, 也由 vinum.ko 改为了 geom_vinum.ko, 而在 /dev/vinum 中的所有设备节点, 也改为放到了 /dev/gvinum。 从 FreeBSD 6 开始, 旧版的 Vinum 实现已不再提供。 磁盘容量太小 Vinum RAID software 磁盘越大,存储的数据也就越多。您经常会发现您需要 一个比您可使用的磁盘大得多的文件系统。 无可否认,这个问题 已经没有十年前那样严峻了,但它仍然存在。通过创建一个在许多 磁盘上存储数据的抽象设备,一些系统可以解决这个问题。 访问瓶颈 现代系统经常需要用一个高度并发的方式来访问数据。 例如,巨大的FTP 或HTTP 服务器可以支持数以千计的并发会话, 可以有多个连到外部世界的100 Mbit/s , 这远远地超过了绝大多数磁盘的数据传输速率。 当前的磁盘驱动器最高可以以70 MB/s的速度传输数据, 但这个值在一个有许多不受约束的进程访问一个驱动器的环境中变得并不重要, 它们可能只完成了这些值的一小部分。这样一种情况下,从磁盘子 系统的角度来看问题就更加有趣:重要的参数是在子系统上的负 荷,换句话说是传输占用了驱动器多少时间。 在任何磁盘传输中, 驱动器必须先寻道, 等待磁头访问第一个扇区, 然后执行传输. 这些动作看起来可能很细小: 我们不会感有任何中断。 假设传输10 kB数据, : 现在的高性能磁盘平均寻道时间是3.5ms。 最快的驱动器可以旋转在15,000 rpm,, 所以平均寻址时间为2ms. 在70 MB/s的速度传输时, 数据的传输时间大约150 μs, 几乎无法和寻址时间相比. 在这样一种情况下, 高效的传输也会降低到 1 MB/s 显然传输的快慢依赖与所传输数据的大小。 对于这个瓶颈的一般和明显的解决方法是采用 多个磁盘:而不是只使用一个大磁盘, 它使用几个比较小的磁盘联合起来形成一个大的磁盘. 每个磁盘都可以独立地进行传输数据,所以通过使用多个磁盘 大大提高了数据吞吐量。 当然,所要求的吞吐量的提高要比磁盘的数量小得多。 尽管每个驱动器并行传输数据,但没有办法确保请求能够平均 分配到每个驱动器上。不可避免一个驱动器的负载可能比另一个要高得多。 磁盘的串连 Vinum 串连 磁盘的负载平衡很大程度依赖于驱动器上数据的共享方式. 在下面的讨论中, 将磁盘存储想象成一个巨大的数据扇区,像一本书的页 那样用编号来设定地址. 最明显的方法是把虚拟磁盘分成许多连续的扇区组, 每个扇区大小就是独立的磁盘大小,用这种方法来存储数据, 就像把一本厚厚的书分成很多小的章节。 这个方法叫做 串联 它有一个优点就是磁盘不需要有任何特定的大小关系。 当访问到的虚拟磁盘根据它的地址空间来分布的时候, 它能工作得很好。 当访问集中在一个比较小的区域的时候,性能的提高没有显著的改进。 举例说明了用串联组织的方式来分配存储单元的顺序。
串联组织
条带盘 Vinum 条带 RAID 另外一种影射方法是把地址空间分布在比较小的容量相同的磁盘上, 从而能够在不同的设备上存储它们。例如,前256 个扇区可能存储在第一 个磁盘上,接着的256 个扇区存储在另一个磁盘上等等。 写满最后一个磁 盘后,进程会重复以前的工作,直到所有的磁盘被写满。这个影射叫做 分段(striping) 或者 RAID-0 RAID 代表廉价冗余磁盘阵列 (Redundant Array of Inexpensive Disks) 提供各种容错机制, 但后面这个术语可能会有些让人误解:它不提供冗余功能。 . 分段要求很精确地寻址,通过多个磁盘进行数据传输的时候,它 可能会引起额外的I/O 负载,但它也可能提供更多的连续负载。 显示了用分段形式分配的存储单元的顺序。
分段组织
数据的完整性 现时磁盘的最后一个问题是它们不太可靠。 虽然磁盘驱动器的可靠性在过去几年有了很大的提高, 但它们仍然是服务器中最容易损坏的核心组件。 当它们发生故障的时候, 结果可能是灾难性的: 替换坏的磁盘驱动器并恢复数据可能要花费几天时间。 磁盘镜像 Vinum 镜像 RAID-1 解决这个问题的传统方法是建立 镜象, 在不同的物理硬件上对数据做两个副本。 根据 RAID 级别出现的时间顺序, 这个技术也被叫做 RAID 级别1 或者 RAID-1。 任何写到卷的数据也会被写到镜象上, 所以可以从任何一个副本读取数据, 如果其中有一个出现故障, 数据也还可以从其他驱动器上访问到。 镜象有两个问题: 价格. 它需要两倍的存储容量。 性能影响。 写入操作必须在两个驱动器上执行,所以它们 花费两倍的带宽。读取数据并不会影响性能: 它们甚至看起来会更快。 RAID-5 一个可选的方案采用 奇偶校验 的方式, 用以实现 RAID 2、 3、 4 和 5。 这其中, RAID-5 是我们最感兴趣的。 在 Vinum 的实现中, 这是一个条带组织结构的变体, 其中, 每一个条带中都以一个专用的块, 来保存其它块的奇偶校验值。 这样, RAID-5 plex 除了在每个块中都包含了一个奇偶校验块之外, 实现 RAID-5 时也就和普通的条带 plex 一样了。 作为 RAID-5 的一项要求, 奇偶校验块在每一个条带中的顺序都是不同的。 数据块的编号, 决定了它的相对块号。
RAID-5 的组织
与镜像相比, RAID-5 最显著的优势在于只需使用少得多的存储空间。 读取类似于条带式存储的组织, 但写入会慢得多, 大约仅相当于读性能的 25%。 如果一个驱动器失效, 则阵列仍然可以在降级的模式运行: 读取来自正常的驱动器数据的操作照常进行, 但读取失效的驱动器的数据, 则来自于余下驱动器上相关的计算结果。
Vinum 目标 为了解决这些问题,Vinum 提出了一个四层的目标结构: 最显著的目标是虚拟磁盘, 叫做 卷(volume). 卷本质上与一个UNIX 磁盘 驱动器有同样的属性,虽然它们是有些不太一样。它们没有大小的限制。 卷下面是 plexes, 每一个表示卷的所有地址空间。在层次结构中的这个水平能够提供 冗余功能。可以把plex 想象成用一个镜象排列的方式组织起来的 独立磁盘,每个都包含同样的数据。 由于Vinum 存在于UNIX 磁盘存储框架中,所以它也可能 使用UNIX 分区作为多个磁盘plex 的组成部分, 但事实上这并不可靠:UNIX 磁盘只能有有限数量的分区。 取而代之,Vinum 把一个简单的UNIX 分区 (the drive) 分解成叫做subdisks的相邻区域, 它可以使用这个 来为plex 建立块。 Subdisks 位于 Vinum 驱动器上, 当前的UNIX 分区。Vinum 驱动器可以包含很多的subdisks。 除了驱动器开始的一小块区域用来存储配置和描述信息以外,整个 驱动器都可以用于存储数据。 下面的章节描述了这些目标提供了Vinum 所要求的功能的方法。 卷的大小要求 在Vinum的配置中,Plex可以把多个subdisk 分布在所有的驱动上。 结果, 每个独立的驱动器的大小都不会限制plex 的大小,从而不会限制卷的大小 多余的数据存储 Vinum 通过给一个卷连上多个plex 来完成镜象的功能。 每个plex 是一个在一个卷中的数据的描述。一个卷可以包含一个 到八个plex。 虽然一个plex 描述了一个卷的所有数据,, 但可能描述的部分被物理地丢失了。可能是设计的问题 (没有为plex 部分定义一个subdisk)也可能是意外的故障 (由于驱动器的故障导致)。只要至少有一个plex 能够为 卷的完全地址范围提供数据,卷就能够正常工作。 性能问题 Vinum 在plex 水平既执行串联也执行分段: 一个串连的plex轮流使用 每个subdisk 的地址空间。 一个 分段的plex 在每个subdisk 上 划分数据. Subdisk 必须是大小一样的,为了从一个连接的plex 中 区分开它,必须至少有两个subdisk。 哪种plex 组织更有效? FreeBSD &rel.current提供的Vinum 版本能实现两种plex: 串联的plex 更加灵活:它们可以包含任何数量的subdisk, subdisk 也可能有不同的长度。Plex 可以通过添加额外的subdisk 来得到扩展。 与分段 plex 不同, 它们需要的 CPU 时钟更少, 尽管 CPU 上的负载差异是不可测量的。 另一方面,它们的负载可能不平衡,一个磁盘可能负载很重, 而其他的可能很空闲。 分段(RAID-0) plexes 的最大优点是 它们减少了负载不平衡的情况: 通过选择一个最合适大小的分段 (大约是256 kB), 您甚至可以在各个组成的驱动器上降低负载 . 这种方法的缺点是在subdisk 上受到非常复杂的编码限制 : 它们必须是同样大小, 通过添加新的subdisk 来扩展一个plex 是非常复杂的,以至Vinum 当前没有实现它. Vinum 利用一个额外 的,代价不高的限制:一个分段的plex 必须有至少两个subdisk, 否则, 它就无法区分连接的 plex 了。 总结一下每个plex 组织 的优点和缺点. Vinum Plex组织图 Plex 类型 最少subdisks 可否添加subdisks 尺寸相同 应用 串联 1 可以 不必须 带有很大弹性和适中性能的大数据量存储。 分段 2 不可以 必须 大量并发访问时,具有较高性能。
一些例子 Vinum 维护着一个描述本系统中对象的 配置数据库。 开始时, 用户可以在 &man.gvinum.8; 工具来从若干配置文件生成配置数据库。 Vinum 在其控制的每个磁盘分区 (在 Vinum 中称为 device) 上都保存配置数据库的副本。 这一数据库在每次状态变化时均会更新, 因而重启每个 Vinum 对象时, 都能够恢复其状态。 配置文件 配置文件描述了独立的 Vinum.一个简单卷的定义可能是这样的: drive a device /dev/da3h volume myvol plex org concat sd length 512m drive a 这个文件描述了四个Vinum 目标: drive 行描述了一个磁盘分区(驱动器) 和与下面的硬件相关的它的位置。它给出了一个符号名 a. 这个与设备名称分开的符号名允许 磁盘从一个位置移动到另一个位置而不会搞混。 volume 行描述了一个卷。 唯一的必须属性是名称,在这个例子中是 myvol. plex 行定义了一个plex。 唯一需要的参数是组织,在这个例子中是 concat. 没有名称是必然的: 系统自动通过添加suffix .px 来从卷名称产生一个名字,这里的x 是在卷中的plex 的编号。而这个plex 将被 叫做myvol.p0 sd 行描述了一个subdisk。 最小的说明是存储subdisk 的驱动器名称,和subdisk 的长度。 对于plex,没有名称也是必然的:系统自动通过添加 suffix .sx 来分配源自plex 的名称,这里 x是plex 中subdisk 的编号。 Vinum 给这个subdisk 命名为myvol.p0.s0 处理完这个文件后, &man.gvinum.8; 会产生下面的输出: &prompt.root; gvinum -> create config1 Configuration summary Drives: 1 (4 configured) Volumes: 1 (4 configured) Plexes: 1 (8 configured) Subdisks: 1 (16 configured) D a State: up Device /dev/da3h Avail: 2061/2573 MB (80%) V myvol State: up Plexes: 1 Size: 512 MB P myvol.p0 C State: up Subdisks: 1 Size: 512 MB S myvol.p0.s0 State: up PO: 0 B Size: 512 MB 这些输出内容展示了 &man.gvinum.8; 的简要列表格式。 在 中用图形展示了这个配置。
一个简单的Vinum 卷
下面这个图显示了一个由按顺序排列的subdisk 组成的plex。 在这个小小的例子中,卷包含一个plex,plex 包含一个subdisk。 这个卷本身和普通的磁盘分区相比并没有什么特别的优越性, 它包含了一个 plex, 因此不是冗余的。 这个 plex 中包括了一个子磁盘, 因此这和从磁盘分区分配存储没什么两样。 接下来的几节, 将介绍一些更有用的配置方法。
提高容错性: 镜像 卷的容错性可以通过镜像来提高。 在配置镜像卷时, 确保 plex 分布在不同的驱动器上十分重要, 这样一个驱动器坏掉时, 就不会同时影响两个 plex。 下面的配置将映射卷: drive b device /dev/da4h volume mirror plex org concat sd length 512m drive a plex org concat sd length 512m drive b 上面的例子中, 并不需要再次指定驱动器 a, 因为 Vinum 监控所有其配置数据库的对象。 完成定义之后, 配置如下所示: Drives: 2 (4 configured) Volumes: 2 (4 configured) Plexes: 3 (8 configured) Subdisks: 3 (16 configured) D a State: up Device /dev/da3h Avail: 1549/2573 MB (60%) D b State: up Device /dev/da4h Avail: 2061/2573 MB (80%) V myvol State: up Plexes: 1 Size: 512 MB V mirror State: up Plexes: 2 Size: 512 MB P myvol.p0 C State: up Subdisks: 1 Size: 512 MB P mirror.p0 C State: up Subdisks: 1 Size: 512 MB P mirror.p1 C State: initializing Subdisks: 1 Size: 512 MB S myvol.p0.s0 State: up PO: 0 B Size: 512 MB S mirror.p0.s0 State: up PO: 0 B Size: 512 MB S mirror.p1.s0 State: empty PO: 0 B Size: 512 MB 以图形方式展示了其结构。
镜像 Vinum 卷
这个例子中, 每一个 plex 包含了完整的 512 MB 地址空间。 在前面的例子中, plex 则只包括一个子盘。
优化性能 前面例子中的镜像卷要比没有镜像的卷具有更好的容灾能力, 但它的性能要差一些: 每一次写入卷时, 需要同时写到两个驱动器上, 因而也就需要更大的磁盘访问带宽。 如果希望非常好的性能, 则需要另外一种方式: 不做镜像, 而将数据分成条带放到尽可能多的、不同的磁盘上。 下面给出了一个跨越四个磁盘驱动器的 plex 卷: drive c device /dev/da5h drive d device /dev/da6h volume stripe plex org striped 512k sd length 128m drive a sd length 128m drive b sd length 128m drive c sd length 128m drive d 和之前类似, 并不需要定义 Vinum 已经知道的驱动器。 在完成定义之后, 将得到如下配置: Drives: 4 (4 configured) Volumes: 3 (4 configured) Plexes: 4 (8 configured) Subdisks: 7 (16 configured) D a State: up Device /dev/da3h Avail: 1421/2573 MB (55%) D b State: up Device /dev/da4h Avail: 1933/2573 MB (75%) D c State: up Device /dev/da5h Avail: 2445/2573 MB (95%) D d State: up Device /dev/da6h Avail: 2445/2573 MB (95%) V myvol State: up Plexes: 1 Size: 512 MB V mirror State: up Plexes: 2 Size: 512 MB V striped State: up Plexes: 1 Size: 512 MB P myvol.p0 C State: up Subdisks: 1 Size: 512 MB P mirror.p0 C State: up Subdisks: 1 Size: 512 MB P mirror.p1 C State: initializing Subdisks: 1 Size: 512 MB P striped.p1 State: up Subdisks: 1 Size: 512 MB S myvol.p0.s0 State: up PO: 0 B Size: 512 MB S mirror.p0.s0 State: up PO: 0 B Size: 512 MB S mirror.p1.s0 State: empty PO: 0 B Size: 512 MB S striped.p0.s0 State: up PO: 0 B Size: 128 MB S striped.p0.s1 State: up PO: 512 kB Size: 128 MB S striped.p0.s2 State: up PO: 1024 kB Size: 128 MB S striped.p0.s3 State: up PO: 1536 kB Size: 128 MB
条带化的 Vinum 卷
这个卷在 中给出。 条带的阴影部分, 表示在 plex 地址空间中的位置: 颜色最浅的在最前面, 而最深的在最后。
高性能容在 如果硬件足够多, 也能够构建比标准 &unix; 分区同时提高了容灾性和性能的卷。 典型的配置文件类似: volume raid10 plex org striped 512k sd length 102480k drive a sd length 102480k drive b sd length 102480k drive c sd length 102480k drive d sd length 102480k drive e plex org striped 512k sd length 102480k drive c sd length 102480k drive d sd length 102480k drive e sd length 102480k drive a sd length 102480k drive b 第二个 plex 中的子盘和第一个 plex 中的错开了两个驱动器: 这能够帮助确保即使同时访问两个驱动器, 写操作也不会同时发生在同一个盘上。 给出了该卷的结构。
镜像并条带化的 Vinum 卷
对象命名 如前面所描述的那样, Vinum 会给 plex 和子盘指定默认的名字, 而这些名字也是可以定制的。 不推荐修改默认的名字: 使用允许给对象任意命名的 VERITAS 卷管理器的经验证明, 这一灵活性并没有带来太多的好处, 相反, 它很容易导致对象的混淆。 名字中可以包括任何非空白的字符, 但一般来说, 建议只使用字母、 数字和下划线。 卷、 plex, 以及子盘的名字, 可以包含最多 64 个字符, 而驱动器的名字, 则最长可以使用 32 个字符。 Vinum 对象会在 /dev/gvinum 之下生成设备节点。 前述的配置将使 Vinum 创建以下设备节点: 这些内容仅适用于旧式的 Vinum 实现。 控制设备 /dev/vinum/control/dev/vinum/controld, 分别由 &man.gvinum.8; 和 Vinum 服务使用。 每个卷对应的设备项。 这些是 Vinum 使用的主要设备。 因此, 前述配置包括下列设备: /dev/gvinum/myvol/dev/gvinum/mirror/dev/gvinum/striped/dev/gvinum/raid5 以及 /dev/gvinum/raid10 这些内容仅适用于旧式的 Vinum 实现。 一个包含每个驱动器对应设备的 /dev/vinum/drive 目录。 这些项事实上是指向对应磁盘节点的符号连接。 所有卷的直接项都存放在 /dev/gvinum/ 中。 目录 /dev/gvinum/plex, 以及 /dev/gvinum/sd 中相应地存放了每个 plex 以及子盘的设备节点。 例如, 考虑下面的配置文件: drive drive1 device /dev/sd1h drive drive2 device /dev/sd2h drive drive3 device /dev/sd3h drive drive4 device /dev/sd4h volume s64 setupstate plex org striped 64k sd length 100m drive drive1 sd length 100m drive drive2 sd length 100m drive drive3 sd length 100m drive drive4 处理这个文件之后, &man.gvinum.8; 将在 /dev/gvinum 中建立下面的结构: drwxr-xr-x 2 root wheel 512 Apr 13 16:46 plex crwxr-xr-- 1 root wheel 91, 2 Apr 13 16:46 s64 drwxr-xr-x 2 root wheel 512 Apr 13 16:46 sd /dev/vinum/plex: total 0 crwxr-xr-- 1 root wheel 25, 0x10000002 Apr 13 16:46 s64.p0 /dev/vinum/sd: total 0 crwxr-xr-- 1 root wheel 91, 0x20000002 Apr 13 16:46 s64.p0.s0 crwxr-xr-- 1 root wheel 91, 0x20100002 Apr 13 16:46 s64.p0.s1 crwxr-xr-- 1 root wheel 91, 0x20200002 Apr 13 16:46 s64.p0.s2 crwxr-xr-- 1 root wheel 91, 0x20300002 Apr 13 16:46 s64.p0.s3 虽然 plex 和子盘一般并不推荐指定名字, 但还是必须给 Vinum 驱动器命名。 这样, 当把驱动器转移到不同的地方时, 它仍然能够被自动地识别出来。 驱动器名最长可以包含 32 个字符。 创建文件系统 对于系统而言, 卷和磁盘是一样的。 唯一的例外是, 与 &unix; 驱动器不同, Vinum 并不对卷进行分区, 因而它也就不包含分区表。 这要求修改某些磁盘工具, 特别是 &man.newfs.8;, 它会试图将 Vinum 卷名当作分区标识。 例如, 磁盘驱动器的名字可能是 /dev/ad0a/dev/da2h。 这些名字分别表达在第一个 (0) IDE (ad) 磁盘上的第一个分区 (a), 以及第三个 (2) SCSI 磁盘 (da) 上的第八个分区 (h)。 而相比而言, Vinum 卷可能叫做 /dev/gvinum/concat, 这个名字和分区名没有什么关系。 一般而言, &man.newfs.8; 会试图解释磁盘的名字, 如果它无法理解这个名字, 则会给出错误提示。 例如: &prompt.root; newfs /dev/gvinum/concat newfs: /dev/gvinum/concat: can't figure out file system partition 要在这个卷上创建文件系统, 则需要使用 &man.newfs.8;: &prompt.root; newfs /dev/gvinum/concat 对于 &os; 5.0 之前的版本, &man.newfs.8; 还需要指定一个 -v 参数, 而且其设备命名方式也是旧式的: &prompt.root; newfs -v /dev/vinum/concat 配置 Vinum GENERIC 内核中, 并不包含 Vinum。 可以编译一个定制的包含 Vinum 的内核, 然而并不推荐这样做。 启动 Vinum 的标准方法, 是使用内核模块 (kld)。 甚至不需要使用 &man.kldload.8; 来启动 Vinum: 在启动 &man.gvinum.8; 时, 它会检查这一模块是否已经加载, 如果没有, 则会自动地加载它。 启动 Vinum 将配置信息, 采用与配置文件一样的形式来存放到磁盘分区上。 当从配置数据库中读取时, Vinum 会识别一系列在配置文件中不可用的关键字。 例如, 磁盘配置文件可能包含下面的文字: volume myvol state up volume bigraid state down plex name myvol.p0 state up org concat vol myvol plex name myvol.p1 state up org concat vol myvol plex name myvol.p2 state init org striped 512b vol myvol plex name bigraid.p0 state initializing org raid5 512b vol bigraid sd name myvol.p0.s0 drive a plex myvol.p0 state up len 1048576b driveoffset 265b plexoffset 0b sd name myvol.p0.s1 drive b plex myvol.p0 state up len 1048576b driveoffset 265b plexoffset 1048576b sd name myvol.p1.s0 drive c plex myvol.p1 state up len 1048576b driveoffset 265b plexoffset 0b sd name myvol.p1.s1 drive d plex myvol.p1 state up len 1048576b driveoffset 265b plexoffset 1048576b sd name myvol.p2.s0 drive a plex myvol.p2 state init len 524288b driveoffset 1048841b plexoffset 0b sd name myvol.p2.s1 drive b plex myvol.p2 state init len 524288b driveoffset 1048841b plexoffset 524288b sd name myvol.p2.s2 drive c plex myvol.p2 state init len 524288b driveoffset 1048841b plexoffset 1048576b sd name myvol.p2.s3 drive d plex myvol.p2 state init len 524288b driveoffset 1048841b plexoffset 1572864b sd name bigraid.p0.s0 drive a plex bigraid.p0 state initializing len 4194304b driveoff set 1573129b plexoffset 0b sd name bigraid.p0.s1 drive b plex bigraid.p0 state initializing len 4194304b driveoff set 1573129b plexoffset 4194304b sd name bigraid.p0.s2 drive c plex bigraid.p0 state initializing len 4194304b driveoff set 1573129b plexoffset 8388608b sd name bigraid.p0.s3 drive d plex bigraid.p0 state initializing len 4194304b driveoff set 1573129b plexoffset 12582912b sd name bigraid.p0.s4 drive e plex bigraid.p0 state initializing len 4194304b driveoff set 1573129b plexoffset 16777216b 这里最明显的区别是, 指定了配置的位置信息、名称 (这些在配置文件中还是可用的, 但不鼓励用户自行指定) 以及状态信息 (这是用户不能指定的)。 Vinum 并不在配置信息中保存关于驱动器的信息: 它会扫描已经配置的磁盘驱动器上包含 Vinum 标识的分区。 这使得 Vinum 能够在 &unix; 驱动器被指定了不同的 ID 时也能够正确识别它们。 自动启动 - 这些内容仅适用于旧式的 - Vinum 实现。 在 Gvinum 内核模块加载时, - 总会执行自动启动操作。 + + 这些内容仅适用于旧式的 Vinum 实现。 + Gvinum 在通过 &man.loader.conf.5; + 加载了内核模块之后就能自动启动。 + 在启动时加载 Gvinum 模块, + 需在 /boot/loader.conf 中加入 + geom_vinum_load="YES" + 要在引导系统时自动启动 Vinum, 需要在 /etc/rc.conf 中加入下面的配置: start_vinum="YES" # set to YES to start vinum 如果您的系统中没有 /etc/rc.conf, 创建一个并加入这些设置就可以了。 这样, 系统就会在启动时自动加载 Vinum 的 kld, 并启动配置中所提到的所有对象。 这是在挂接文件系统之前进行的, 因此, &man.fsck.8; 和挂接文件系统都能够自动地在 Vinum 卷上进行。 当使用 vinum start 命令来启动 Vinum 时, Vinum 会从某一个 Vinum 驱动器中读取配置数据库。 正常情况下, 每个驱动器上都包含了同样的配置数据库副本, 因此从哪个驱动器上读取是无所谓的。 但是, 在系统崩溃之后, Vinum 就必须检测哪一个驱动器上的配置数据库是最新的, 并从上面读取配置。 如果需要, 它会更新其它驱动器上的配置。 使用 Vinum 作为根文件系统 如果文件系统使用完全镜像的 Vinum 配置, 有时也会希望根文件系统也作了镜像。 这种配置要比镜像其它文件系统麻烦一些, 因为: 根文件系统在引导过程中很早的时候就必须处于可用状态, 因此 Vinum 的基础设施在这一时刻就应该可用了。 包含根文件系统的卷, 同时也保存了系统的引导程序和内核, 因此它们必须能够被宿主系统的内建工具 (例如 PC 机的 BIOS) 识别, 而通常是没办法让它们了解 Vinum 的细节的。 下面几节中, 术语 根卷 标识包含根文件系统的 Vinum 卷。 把这个卷命名为 "root" 可能是个不错的主意, 不过从技术上说, 并不严格地要求这样做。 不过, 接下来的命令例子都使用这个名字。 及早启动 Vinum 以适应对根文件系统的要求 有许多关于它的尺度: Vinum 必须在启动时可以被内核使用。 因此, 在 中所介绍的方法, 也就无法适应这一任务的需要了。 在接下来的配置中, 也 不能 设置 start_vinum 参数。 第一种方法是通过将 Vinum 静态联编到内核中来实现, 这样, 它就在任何时候都可用了, 虽然一般并不需要这样。 另一种方法是通过 /boot/loader () 来尽早加载 vinum 内核模块, 这一操作发生在内核加载之前。 这可以通过将下面的配置: geom_vinum_load="YES" 加入到 /boot/loader.conf 文件中来实现。 Gvinum 而言, 所有的启动过程都是在内核模块加载时自动进行的, 因此上面的操作, 也就是所要进行的全部工作了。 下面的文字介绍的是旧式的 Vinum 系统, 保留它们的主要是为了方便那些使用旧版系统的用户。 Vinum 必须尽早初始化, 因为需要由它来提供根文件系统的卷。 默认情况下, Vinum 的内核部分并不主动地查找可能包含 Vinum 卷信息的驱动器, 而会等待管理员 (或者某个启动脚本) 来执行 vinum start 命令。 下面介绍的是 FreeBSD 所需的配置。 通过将下面的配置: vinum.autostart="YES" 加入 /boot/loader.conf, Vinum 将在内核部分初始化的过程中, 自动地扫描所有的驱动器以查找 Vinum 信息。 需要说明的是, 并不需要指定内核到什么地方去找根文件系统。 /boot/loader 会在 /etc/fstab 中查找根文件系统的设备名, 并将这一信息转交给内核。 当需要挂接根文件系统时, 内核会根据设备名来知道它由哪个驱动提供, 并将其转译为内部设备 ID (major/minor 编号)。 让基于 Vinum 的卷在引导时可以访问 因为目前的 FreeBSD 引导程序只有 7.5 KB 的代码, 并且已经承担了从 UFS 文件系统中读取文件 (例如 /boot/loader) 的重任, 因此完全没有办法再让它去分析 Vinum 配置数据中的 Vinum 结构, 并找到引导卷本身的信息。 因此, 需要一些技巧来为引导代码提供标准的 "a" 分区, 而它则包含了根文件系统。 要让这些得以实现, 根卷需要满足下面的条件: 根卷不能是条带卷或 RAID-5 卷。 根卷 plex 不能包含连接的子盘。 需要说明的是, 使用多个 plex, 每个 plex 都复制一份根文件系统的副本, 是需要而且是可行的。 然而, 引导过程只能使用这些副本中的一个来引导系统, 直到内核最终自行挂接根文件系统为止。 这些 plex 中的每个子盘, 在这之后会有它们自己的 "a" 分区, 以表达每一个可以引导的设备。 每一个 "a" 分区, 尽管并不需要和其它包含根卷的 plex 处于各自驱动器的同一位置。 但是, 这样创建 Vinum 卷使得镜像卷相互对称, 从而能够避免了混淆。 为了创建每一个根卷的 "a" 分区, 需要完成下面的操作: 使用下面的命令来了解根卷成员子盘的位置 (从设备开始的偏移量) 和尺寸: &prompt.root; gvinum l -rv root 需要注意的是, Vinum 偏移量和尺寸的单位是字节。 它们必须是 512 的整数倍, 才能得到 bsdlabel 命令所需的块号。 在每一个根卷成员设备上, 执行命令: &prompt.root; bsdlabel -e devname 这其中, 对于没有 slice (也就是 fdisk) 表的磁盘, devname 必须是磁盘的名字 (例如 da0), 或者是 slice 的名字 (例如 ad0s1)。 如果设备上已经有了 "a" 分区 (比如说, 包含 Vinum 之前的根文件系统), 则应改为其它的名字, 以便继续访问 (如果需要的话), 但它并不会继续用于启动系统。 注意, 活动的分区 (类似正挂接的根文件系统) 不能被改名, 因此, 要完成这项工作, 必须从 Fixit 盘启动, 或者分两步操作, 并 (在镜像情形中) 首先操作那些非引导盘。 然后, 设备上 Vinum 分区的偏移 (如果有的话) 必须加到这个设备上根卷对应的子盘上。 其结果值, 将成为新的 "a" 分区的 "offset" 值。 这个分区的 "size" 值, 可以根据前面的配置计算得出。 "fstype" 应该是 4.2BSD"fsize""bsize", 以及 "cpg" 值, 则应与文件系统的实际情况匹配, 尽管在配置 Vinum 时并不重要。 这样, 新的 "a" 分区, 将创建并覆盖这一设备上的 Vinum 分区的范围。 注意, bsdlabel 只有在 Vinum 分区的 fstype 被标记为 "vinum" 时, 才允许这样做。 这就成了! 所有的 "a" 分区现在都已存在, 而且是根卷的一份副本。 强烈建议您再次验证其结果, 方法是: &prompt.root; fsck -n /dev/devnamea 务必注意, 所有包含控制信息的文件, 都必须放到 Vinum 卷上的根文件系统。 在启动新的 Vinum 根卷时, 它们可能和实际在用的根文件系统不匹配。 因此, /etc/fstab/boot/loader.conf 这两个文件需要特别地注意。 在下次重启时, 引导程序需要从新的基于 Vinum 的根文件系统中获取适当的控制信息, 并据此工作。 在内核初始化过程的结尾部分, 在所有的设备都被宣示之后, 如果显示了下面的信息, 则表示配置成功: Mounting root from ufs:/dev/gvinum/root 基于 Vinum 的根文件系统的配置范例 在 Vinum 根卷配置好之后, gvinum l -rv root 的输出可能类似下面的样子: ... Subdisk root.p0.s0: Size: 125829120 bytes (120 MB) State: up Plex root.p0 at offset 0 (0 B) Drive disk0 (/dev/da0h) at offset 135680 (132 kB) Subdisk root.p1.s0: Size: 125829120 bytes (120 MB) State: up Plex root.p1 at offset 0 (0 B) Drive disk1 (/dev/da1h) at offset 135680 (132 kB) 需要注意的值是 135680, 也就是偏移量 (相对于 /dev/da0h 分区)。 这相当于 bsdlabel 记法中的 265 个 512-字节的磁盘块。 类似地, 根卷的尺寸是 245760 个 512-字节的磁盘块。 /dev/da1h 中, 包含了根卷的第二个副本, 采用了同样的配置。 这些设备的 bsdlabel 类似下面的样子: ... 8 partitions: # size offset fstype [fsize bsize bps/cpg] a: 245760 281 4.2BSD 2048 16384 0 # (Cyl. 0*- 15*) c: 71771688 0 unused 0 0 # (Cyl. 0 - 4467*) h: 71771672 16 vinum # (Cyl. 0*- 4467*) 可以看到, 伪装的 "a" 分区的 "size" 参数和前面的一样, 而 "offset" 参数则是 Vinum 分区 "h", 以及设备中这一分区 (或 slice) 的偏移量之和。 这是一种典型的配置, 它能够避免在 中介绍的问题。 此外, 我们也看到整个 "a" 分区完全处于设备上包含了 Vinum 数据的 "h" 分区之中。 注意, 在上面的配置中, 整个设备都是 Vinum 专用的, 而且没有留下 Vinum 之前的根分区, 因为它永久性地成为了新建的 Vinum 配置中的一个子盘。 故障排除 如果遇到了问题, 则需要从中恢复的办法。 下面列出了一些常见的缺陷, 及其解决方法。 系统的引导程序加载了, 但无法启动 如果由于某种原因系统不再继续启动, 引导程序可以在 10-秒 倒计时的时候, 按 space 键来停止。 加载器变量 (例如 vinum.autostart) 可以通过使用 show 命令来查看, 并使用 setunset 命令来设置。 如果遇到的问题是由于 Vinum 的内核模块没有列入预加载的列表, 而没有正确加载, 则简单使用 load geom_vinum 会有所帮助。 此后, 可以使用 boot -as 来继续启动过程。 选项 会要求内核询问所挂接的根文件系统 (), 并使引导过程在单用户模式停止 (), 此时根文件系统是以只读方式挂接的。 这样, 即使只挂接了多 plex 卷中的一个 plex, 也不会引致 plex 之间数据不一致的问题。 当提示输入要挂接的根文件系统时, 可以输入任何一个包含根文件系统的设备。 如果正确地配置了 /etc/fstab, 则默认的应该是类似 ufs:/dev/gvinum/root。 一般可以使用类似 ufs:da0d 这样的设备来代替它, 因为它通常包括了 Vinum 之前的根文件系统。 需要注意的是, 如果在这里输入了 "a" 分区, 则它可能表达的实际上是 Vinum 根设备的一个子盘, 而在镜像式配置中, 这只会挂接镜像的根设备中的一个。 如果之后将这个文件系统以读写方式挂接, 则需要从 Vinum 根卷中删去其他的 plex, 否则这些卷中可能会包含不一致的数据。 只加载了主引导程序 如果 /boot/loader 加载失败, 而主引导程序加载正常 (在启动时, 屏幕最左边一列有一个旋转的线), 则可以尝试在此时中断主引导程序的过程, 方法是按 space 键。 这将在引导的第二阶段暂停, 具体可以参见 。 此时, 可以尝试从另一个分区, 例如原先包含根文件系统, 并不再叫作 "a" 的那个分区, 启动。 无法启动, 引导程序发生 panic 这种情况一般是由于 Vinum 安装过程中破坏了引导程序造成的。 不幸的是, Vinum 目前只在分区开始的地方保留了 4 KB 的空间, 之后就开始写 Vinum 头信息了。 然而, 目前第一阶段和第二阶段的引导程序, 加上 bsdlabel 嵌入的内容则需要 8 KB。 因此, 如果 Vinum 分区从偏移量 0 开始, 而这个 slice 或磁盘能够启动, 则 Vinum 的安装将毁掉引导程序。 类似地, 如果从上述情形中恢复, 例如, 从 Fixit 盘启动, 并通过 bsdlabel -B 按照 中介绍的方法来恢复引导程序, 则引导程序会覆盖掉 Vinum 头, 这样 Vinum 也就找不到它的磁盘了。 尽管这并不会真的毁掉 Vinum 的配置数据, 或者 Vinum 卷上的数据, 并且可以通过输入一模一样的 Vinum 配置数据来恢复, 但从这种状况中完全恢复是非常困难的。 要真正解决问题, 必须将整个 Vinum 分区向后移动至少 4 KB, 以便使 Vinum 头和系统的引导程序不再冲突。