Page MenuHomeFreeBSD

powerpc: change mfpvr return type to uint32_t
ClosedPublic

Authored by luporl on Jul 28 2021, 12:41 PM.
Tags
None
Referenced Files
Unknown Object (File)
Mon, May 13, 4:25 AM
Unknown Object (File)
Sun, May 12, 9:29 PM
Unknown Object (File)
Sun, May 5, 2:32 AM
Unknown Object (File)
Thu, Apr 25, 7:01 AM
Unknown Object (File)
Apr 20 2024, 3:40 AM
Unknown Object (File)
Apr 20 2024, 12:50 AM
Unknown Object (File)
Apr 16 2024, 4:47 AM
Unknown Object (File)
Feb 22 2024, 3:13 AM
Subscribers

Details

Summary

As the Processor Version Register (PVR) is a 32-bit PowerPC
register, change mfpvr() return type to match it and avoid
type casts on its callers.

Suggested by: jhibbits

Test Plan

Tested on POWER9 VM and build tested on powerpc (32-bit).

Diff Detail

Repository
rG FreeBSD src repository
Lint
Lint Not Applicable
Unit
Tests Not Applicable

Event Timeline

This revision is now accepted and ready to land.Jul 28 2021, 2:21 PM

minor quibble, but likely not worth addressing.

sys/dev/hwpmc/hwpmc_powerpc.c
607

mfpvr() doesn't return an int now, but a uint32_t which can be either an int or a long. so there's still a mismatch here, just not one the compiler warns about. In the past, this would be a sure way to get a mismatch between 32-bit and 64-bit compiles, but it seems we've moved to always defining uint32_t as an unsigned int. At least the 'x' format is unsigned...

This revision was automatically updated to reflect the committed changes.